About this file

The document is a Mechanical Duct Demolition Plan (M101) for Building 1005 at a Marine Corps Base, detailing comprehensive demolition of existing HVAC and mechanical systems. The plan includes systematic removal of multiple mechanical components such as PTAC units, VAV systems with hot water coils, baseboard heaters, air handling systems (AH-1 and AH-2), heat pumps (HP1 and HP2), ductless split systems, unit heaters, exhaust fans, range hoods, ductwork, and associated equipment and concrete pads. The demolition is part of a wing relocation project, with specific annotations marking the precise area of work and methodical removal of various mechanical infrastructure across different rooms and zones of the building.

View the file

Other files

File Type Posted
N4008524R2785 Amendment 0007.pdf PDF
23 73 33_Amendment 2.pdf PDF
E-103.pdf PDF
E-104.pdf PDF
E-107.pdf PDF
M601.pdf PDF
N4008524R2785 Amendment 0006.pdf PDF
VMR- uncapped.jpg JPG image
E-101.pdf PDF
E-105.pdf PDF
M103.pdf PDF
M104.pdf PDF
M602.pdf PDF
A-202.pdf PDF
E-106.pdf PDF
M802.pdf PDF
VMR- capped.jpg JPG image
N4008524R2785 Amendment 0005.pdf PDF
01 32 16.00 20.pdf PDF
22 00 00.pdf PDF
23 09 23.13 20 Attachment 2.pdf PDF
23 09 00.pdf PDF
23 09 23.13 20 Attachment 4.pdf PDF
N4008524R2785 Amendment 0004.pdf PDF
Attachment Q - Revised Drawings.pdf PDF
23 09 23.13 20 Attachment 5.pdf PDF
23 09 13.pdf PDF
23 09 23.02.pdf PDF
Attachment M - Specifications TOC.pdf PDF
Attachment N - Revised Eletrical-Telecomm Sheets.pdf PDF
Attachment O - Revised Specs pg3.pdf PDF
N4008524R2785 Amendment 0003.pdf PDF
Attachment P - Site Visit Log.pdf PDF
N4008524R2785 Amendment 0002.pdf PDF
Attachment I - Site Visit Information REVISED.pdf PDF
Attachment J - Site Visit Participant Log.xlsx XLSX spreadsheet
Attachment L - Electrical Room.pdf PDF
Attachment I - Site Visit Information.pdf PDF
N4008524R2785 Amendment 0001.pdf PDF
Attachment K - Asbestos Inspection Report.pdf PDF
N4008524R2785 Small Business Marine Corps MACC for General Construction.pdf PDF
Attachment A - PPI LOG TEMPLATE.xlsx XLSX spreadsheet
Attachment B - CONSTRUCTION AND DESIGN EXPERIENCE PROJECT DATA.docx DOCX document
Attachment E - B1005 Drawings.pdf PDF
Attachment F - B1005 Specifications.pdf PDF
Attachment H - PIEE VENDOR ACCESS INSTRUCTIONS.pdf PDF
N4008524R2785 Small Business Marine Corps MACC for General Construction.pdf PDF
Attachment C- PAST PERFORMANCE QUESTIONNAIRE.docx DOCX document
Attachment D - B1005 Price Proposal Form.docx DOCX document
Attachment G - B1005 Statement of Work.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

/2

/2

20/16 24/20

26/2618/16

DEMOLISH PTAC AND

FILL VOID IN WALL

DEMOLISH VAV WITH

HOT WATER COIL (TYP.)

DEMOLISH BASEBOARD

HEATER (TYP.)

DEMOLISH AH-2 SYSTEM

DEMOLISH AH-1 SYSTEM

DEMOLISH HP1,

PIPING, AND PAD

DEMOLISH DUCTLESS SPLIT

SYSTEM, PIPING, AND PAD

DEMOLISH AHU-2 SYSTEM,

ALL RELATED DUCTWORK, AND

EXISTING CONCRETE PAD

DEMOLISH LOUVER

DESIGN WING RELOCATION

BUILDING 1005

DEMOLISH RANGE HOOD

AND EXHAUST DUCT

DEMOLISH WALL MOUNTED

UNIT AND FILL VOID IN WALL

DEMOLISH HP2,

PIPING, AND PAD

DEMOLISH UNIT HEATER

DEMOLISH EXHAUST FAN

MECHANICAL DUCT DEMO PLAN1

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

ESTCODE

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

J F ORR PE

AutoCAD SHX Text

SATISFACTORY TO: DATE

AutoCAD SHX Text

APPROVED: PWO OR OICC DATE

AutoCAD SHX Text

DESIGN DIR.

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DR.

AutoCAD SHX Text

CHK.

AutoCAD SHX Text

DES.

AutoCAD SHX Text

C MAAS

AutoCAD SHX Text

J BELY

AutoCAD SHX Text

CAMP LEJEUNE, NORTH CAROLINA

AutoCAD SHX Text

CONST. CONTR.

AutoCAD SHX Text

MECHANICAL - HVAC DEMO

AutoCAD SHX Text

MARINE CORPS BASE

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

AutoCAD SHX Text

SCALE: NOTED

AutoCAD SHX Text E1

AutoCAD SHX Text

SIZE

AutoCAD SHX Text 80091

AutoCAD SHX Text

CODE IDENT. NO

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text M101

AutoCAD SHX Text

J BELY

AutoCAD SHX Text

K ROOT

AutoCAD SHX Text 60036674

AutoCAD SHX Text 12'

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text 16'

AutoCAD SHX Text 20'

AutoCAD SHX Text

NA

AutoCAD SHX Text 21-0019

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text 05-21-0019

AutoCAD SHX Text

SCALE: 3/16" = 1'-0"

AutoCAD SHX Text M101

AutoCAD SHX Text

CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

DEMOLITION NOTES:

AutoCAD SHX Text

1. NOT ALL WORK IS EXPLICITLY SHOWN ON THE DRAWINGS. MAKE ALL NECESSARY MINOR CORRECTIONS AND NOT ALL WORK IS EXPLICITLY SHOWN ON THE DRAWINGS. MAKE ALL NECESSARY MINOR CORRECTIONS AND ADJUSTMENTS TO DELIVER A FULLY FUNCTIONAL AND COMPLETE SYSTEM. 2. PROVIDE PUBLIC WORKS OPPORTUNITY TO SALVAGE ALL EXISTING DDC EQUIPMENT TO BE DEMOLISHED. PROVIDE 14 PROVIDE PUBLIC WORKS OPPORTUNITY TO SALVAGE ALL EXISTING DDC EQUIPMENT TO BE DEMOLISHED. PROVIDE 14 DAYS NOTICE PRIOR TO DEMOLITION. 3. DEMOLISH ENTIRE MECHANICAL AND DDC SYSTEM COMPLETE WITHIN AREA OF WORK. EXISTING DDC FOR AREAS NOT DEMOLISH ENTIRE MECHANICAL AND DDC SYSTEM COMPLETE WITHIN AREA OF WORK. EXISTING DDC FOR AREAS NOT UNDER CONSTRUCTION MUST REMAIN OPERATIONAL. 4. DEMOLISH EXISTING ROOF VENTS FOR EXHAUST HOOD, AH-1, AND AH-2. PATCH ROOF PENETRATIONS TO COMPLY DEMOLISH EXISTING ROOF VENTS FOR EXHAUST HOOD, AH-1, AND AH-2. PATCH ROOF PENETRATIONS TO COMPLY WITH ROOF MANUFACTURER'S WARRANTY.

AutoCAD SHX Text

ADDED DEMO NOTE

AutoCAD SHX Text 03/12/25

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AMENDMENT 2. ADDED DEMO NOTE

AutoCAD SHX Text 03/28/25

AutoCAD SHX Text

Sheets and Views
M101

File details come from the government source that posted it. Updated .