This document is a Mechanical Supply Duct Plan engineering drawing for Building 1005 at a Marine Corps Base, part of a Design Wing Relocation project. The detailed architectural blueprint shows a comprehensive mechanical ductwork layout across multiple rooms, featuring various valve (VAV) configurations and labeled mechanical supply duct routing. The drawing is part of construction documents for the Naval Facilities Engineering Command, specifically associated with an IDIQ Small Business Multiple Award Construction Contract for general construction projects at Marine Corps Base Camp Lejeune and Marine Corps Air Station Cherry Point. The technical drawing is scaled at 3/16"=1'-0" and includes specific design notes about ductwork installation requirements, room considerations, and system integration details.

View the file

Other files

File Type Posted
N4008524R2785 Amendment 0008.pdf PDF
N4008524R2785 Amendment 0007.pdf PDF
M101_rev 2.pdf PDF
N4008524R2785 Amendment 0006.pdf PDF
VMR- uncapped.jpg JPG image
E-101.pdf PDF
E-105.pdf PDF
M104.pdf PDF
M602.pdf PDF
23 73 33_Amendment 2.pdf PDF
E-103.pdf PDF
E-104.pdf PDF
E-107.pdf PDF
M601.pdf PDF
VMR- capped.jpg JPG image
T-1.pdf PDF
25 05 11.00.pdf PDF
A-105.pdf PDF
A-501.pdf PDF
E-102.pdf PDF
M501.pdf PDF
N4008524R2785 Amendment 0005.pdf PDF
23 09 00.pdf PDF
23 09 23.13 20 Attachment 4.pdf PDF
01 32 16.00 20.pdf PDF
22 00 00.pdf PDF
23 09 23.13 20 Attachment 2.pdf PDF
23 09 13.pdf PDF
23 09 23.02.pdf PDF
Attachment N - Revised Eletrical-Telecomm Sheets.pdf PDF
Attachment O - Revised Specs pg3.pdf PDF
Attachment M - Specifications TOC.pdf PDF
N4008524R2785 Amendment 0003.pdf PDF
Attachment P - Site Visit Log.pdf PDF
N4008524R2785 Amendment 0002.pdf PDF
Attachment I - Site Visit Information REVISED.pdf PDF
Attachment I - Site Visit Information.pdf PDF
Attachment J - Site Visit Participant Log.xlsx XLSX spreadsheet
Attachment L - Electrical Room.pdf PDF
N4008524R2785 Amendment 0001.pdf PDF
Attachment K - Asbestos Inspection Report.pdf PDF
Attachment A - PPI LOG TEMPLATE.xlsx XLSX spreadsheet
Attachment B - CONSTRUCTION AND DESIGN EXPERIENCE PROJECT DATA.docx DOCX document
Attachment E - B1005 Drawings.pdf PDF
Attachment F - B1005 Specifications.pdf PDF
Attachment H - PIEE VENDOR ACCESS INSTRUCTIONS.pdf PDF
N4008524R2785 Small Business Marine Corps MACC for General Construction.pdf PDF
Attachment C- PAST PERFORMANCE QUESTIONNAIRE.docx DOCX document
Attachment D - B1005 Price Proposal Form.docx DOCX document
Attachment G - B1005 Statement of Work.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

315 317

321319

"x

16"x16"

"x

6"x10"

8"x10"

8"x12" 6"X10"

6"x10"

"x

"x

8"x10" 8"x10"

8" x1

0"

"x

8"x12" 6"x10"

8"x12"

"x

8"x12"6"x10"

12"x14"

12"x12"

303 8"x12"

26"x26" 20"x20"

DESIGN WING RELOCATION

BUILDING 1005

MECHANICAL SUPPLY DUCT PLAN1

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

J F ORR PE

AutoCAD SHX Text

SATISFACTORY TO: DATE

AutoCAD SHX Text

APPROVED: PWO OR OICC DATE

AutoCAD SHX Text

DESIGN DIR.

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DR.

AutoCAD SHX Text

CHK.

AutoCAD SHX Text

DES.

AutoCAD SHX Text

C MAAS

AutoCAD SHX Text

J BELY

AutoCAD SHX Text

CAMP LEJEUNE, NORTH CAROLINA

AutoCAD SHX Text

CONST. CONTR.

AutoCAD SHX Text

MECHANICAL - HVAC SUPPLY DUCTWORK

AutoCAD SHX Text

MARINE CORPS BASE

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

AutoCAD SHX Text E1

AutoCAD SHX Text

SIZE

AutoCAD SHX Text 80091

AutoCAD SHX Text

CODE IDENT. NO

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text M103

AutoCAD SHX Text

J BELY

AutoCAD SHX Text

K ROOT

AutoCAD SHX Text 60036676

AutoCAD SHX Text 12'

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text 16'

AutoCAD SHX Text 20'

AutoCAD SHX Text

NA

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text

VAV 2-20

AutoCAD SHX Text

VAV 2-01

AutoCAD SHX Text

VAV 2-02

AutoCAD SHX Text

VAV 2-03

AutoCAD SHX Text

VAV 2-04

AutoCAD SHX Text

VAV 2-05

AutoCAD SHX Text

VAV 2-06

AutoCAD SHX Text

VAV 2-07

AutoCAD SHX Text

VAV 2-08

AutoCAD SHX Text

VAV 2-09

AutoCAD SHX Text

VAV 2-10

AutoCAD SHX Text

VAV 2-11

AutoCAD SHX Text

VAV 2-12

AutoCAD SHX Text

VAV 2-13

AutoCAD SHX Text

VAV 2-14

AutoCAD SHX Text

VAV 2-15

AutoCAD SHX Text

VAV 2-16

AutoCAD SHX Text

VAV 2-17

AutoCAD SHX Text

VAV 2-18

AutoCAD SHX Text

VAV 2-19

AutoCAD SHX Text

VAV 2-21

AutoCAD SHX Text 21-0019

AutoCAD SHX Text

SCALE: NOTED

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text 05-21-0019

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

%%UNEW WORK KEYNOTES:

AutoCAD SHX Text INSTALL SPLIT SYSTEM AS HIGH AS POSSIBLE ON THE SAME WALL AS THE DOOR. MAINTAIN ALL MANUFACTURER REQUIRED CLEARANCES. ROUTE CONDENSATE AND REFRIGERANT PIPES THROUGH ATTIC. DO NOT TRAVERSE THE TELECOM ROOM WITH ANY PIPING. PLACE OUTDOOR UNIT ON CONCRETE PAD. PAD TO EXTEND 6" PAST UNIT ON ALL SIDES. PAD TO BE 6" ABOVE GRADE. DOOR LOCATION MUST BE ADJUSTED TO ALLOW FOR COIL PULL. LOCATION SHOWN ON PLANS IS FOR BASIS OF DESIGN. ANY CHANGES DUE TO DIFFERENCES BETWEEN BASIS OF DESIGN AND CONTRACTOR PROCURED EQUIPMENT MUST BE RESOLVED AT NO ADDITIONAL COST TO THE GOVERNMENT. BALANCE THREE EXISTING DOWNSTREAM DIFFUSERS TO 200 CFM EACH.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UH

AutoCAD SHX Text

AutoCAD SHX Text

EF

AutoCAD SHX Text

AutoCAD SHX Text

AH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 3/16" = 1'-0"

AutoCAD SHX Text M103

AutoCAD SHX Text

AutoCAD SHX Text

SS

AutoCAD SHX Text

AutoCAD SHX Text

SS

AutoCAD SHX Text

CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

AutoCAD SHX Text

%%UNEW WORK GENERAL NOTES:

AutoCAD SHX Text UL LISTED FIRE DAMPERS FOR P533 ASSEMBLY MUST BE PROVIDED AT ALL SUPPLY PENETRATION LOCATIONS.

AutoCAD SHX Text

AMENDMENT 2. CHANGED SUPPLY SIZES.

AutoCAD SHX Text 03/28/25

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
M103

File details come from the government source that posted it. Updated .