This document provides specifications for an accommodation ladder repair project aboard the USS Vindicator (TSV 5). The Navy seeks fabrication, fitting, and installation of a new accommodation ladder at location 01 Level, Weather, Frame 65, port side. The contractor must accomplish welding and painting requirements and pass a static load test of the assembled ladder. The contractor will remove and replace 10 square feet of deteriorated structure. The Navy will provide materials including vang staples, rigging hardware, and a rotating upper platform. The solicitation requests repair and overhaul of the Vindicator (TSV 5) ship including drydocking, pier-side maintenance, and ABS-certified repairs and upgrades to systems such as propulsion, power, steering, and outfitting. The solicitation was issued for full and open competition under NAICS code 336611.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIS PERMANENT CHANGE UPDATES THE SPECIFICATION BID PACKAGE.
SHIP: COMMANDER CARRIER STRIKE GROUP FOUR (CNRMC 9577)
SERM-507-22
ERRATA NUMBER:
SPECIFICATION NUMBER:
THE FOLLOWING ITEMS ARE REPLACED:
623-21-001
DATED: 8/30/2022 1:30:20PMPage 1 of 1
SHIP: COMMANDER CARRIER STRIKE GROUP
FOUR (CNRMC 9577)
ITEM NO: 623-21-001 (E7)
COAR: 12 PCN: TSV5-0025
CSWT FILE NO: 623-012 (CG 47) CMP: NONE
REVISED: 12 OCT 2021 PLANNER: See Attachment A
SSP: SERM-507-22 1 of 3 ITEM NO: 623-21-001
ERRATA NO. 7
EXPORT CONTROLLED DATA: This document contains technical information whose export is governed by U.S.
International Traffic in Arms Regulation (ITAR). This information must not be transferred to a foreign person/entity without proper authorization of the U.S. Government. Violations may result in administrative, civil, or criminal penalties.
1. SCOPE:
1.1 Title: Accommodation Ladder, Fabricate, Fit, and Install; accomplish
(OPTION ITEM)
1.2 Location of Work:
1.2.1 01 Level, Weather, Frame 65, Port
1.3 Identification:
1.3.1 Quantity (One AY), Accommodation Ladder
2. REFERENCES:
2.1 LAR 87mNS-2218, Accommodation Ladder Details (E6)
2.2 805-1749049 Rev J, Gangway Aluminum (E6)
2.3 804-2255404, Accommodation Ladder Upper Platform Types A, B, and C (E6)
2.4 805-1749040, Accommodation Ladder Arrangement Handling and Stowage Fixed or Feathering Thread
(E6)
2.5 601-5113194, 87mNS1401 Vindicator (TSV 5) General Arrangement (E6)
2.6 American Bureau of Shipping (ABS), Part 7, Rules For Survey After Construction
(E6)
2.7 American Bureau of Shipping (ABS), Part 2, Rules for Materials and Welding
(E6)
2.8 LAR 87mNS-2217 Rev A, Accommodation Ladder (E7)
2.9 PM 390-563 Rev A, SERMC, Vindicator TSV-5 Paint Schedule (E6)
3. REQUIREMENTS:
3.1 Provide the service of an American Bureau of Shipping (ABS) certified Surveyor.
3.2 Accomplish the requirements of 2.2 1 through 2.4,5 and 2.8, using
2.5 6 through , 2.7 and 2.8 9 for guidance.
(E6)
3.2.1 Fabricate, fit and install new accommodation ladder, including the upper and lower platform and fender assembly. The yoke guide will be mounted onto a Type 316L corrosion resistant steel reinforcement plate welded to ships support structure, listed in 1.3, and located in 1.2.
3.2.2 Remove existing and install new a total of 10 square feet of damaged or deteriorated plating and associated support structure.
3.2.3 Accomplish the requirements of Chapter 4 of 2.7 for welding.
SSP: SERM-507-22 2 of 3 ITEM NO: 623-21-001
EXPORT CONTROLLED DATA: This document contains technical information whose export is governed by U.S.
International Traffic in Arms Regulation (ITAR). This information must not be transferred to a foreign person/entity without proper authorization of the U.S. Government. Violations may result in administrative, civil, or criminal penalties.
(I)(G) "STATIC LOAD TEST"
3.3 Accomplish a static load test of each accommodation ladder assembly in accordance with General Note 3 of 2.2. Accept/Reject Criteria: No visible evidence of damage or permanent deformation. None.
(V)(G) "PROPER FIT"
3.4 Verify proper fit of the accommodation ladder, with no binding between equipment and each stowage rack. Ensure each quick release pin and toggle pin with lanyard are secured to stowage structure and equipment, using 2.2 and 2.4 for guidance.
3.5 Accomplish painting requirements for each new and disturbed surface,surface in accordance with 2.9, as approved by Operator, Owner's Specifications, American ABS Bureau of Shipping (ABS) certified Surveyor and in accordance with the paint manufacturer's recommendation recommendation.and using 2.7 for guidance.
(E1)
4. NOTES:
4.1 None.
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 LLTM:
TOTAL
QUANTITY
PROVIDED NAME Of PART
PIECE
NO.
REF
NO.
NATIONAL
STOCK
NO.
REQ
PARA NO.
1. 1 KT Vang Staples 2.3 (E3)
2. 1 KT
Rigging Hardware
ACCOM 2.3 (E3)
3. 1 EA
Rotating Upper Platform N/A 2.5 N/A 3.3 (E3)
5.2 PUSH MATERIAL:
1. None.
5.3 KITTED MATERIAL:
1. None.
SSP: SERM-507-22 3 of 3 ITEM NO: 623-21-001
EXPORT CONTROLLED DATA: This document contains technical information whose export is governed by U.S.
International Traffic in Arms Regulation (ITAR). This information must not be transferred to a foreign person/entity without proper authorization of the U.S. Government. Violations may result in administrative, civil, or criminal penalties.
Attachment A
Planners
CORNWELL, RICHARD
BENNETT, KEITH
BRIDGER, WRAY
BROWN, DERRICK
DUNCAN, CHRISTOPHER
MILLION, GARY
File details come from the government source that posted it. Updated .