Attachment X - RTC BID DWGS 8 2025.1023.pdf
PDF 18 MB Posted
- Attached to
- Z2DA--Remediate Temperature Controls 539-21-108 Federal contract opportunity
- Solicitation number
- 36C25026B0002
About this file
These architectural floor plan drawings for the Cincinnati VA Medical Center depict construction documents for multiple buildings, including Buildings 2, 3, 13, 14, and 15. The drawings, prepared by Heapy Engineering and Levin Porter Architects for the U.S. Department of Veterans Affairs, show basement and first floor plans at 1/8" or 1/16" scale, with detailed room layouts, mechanical spaces, corridors, and electrical equipment locations. The project number is 2020-05099, with Kevin Henderson listed as the project manager, and the plans are dated 10/23/2025. Each building's floor plan includes specific room designations such as mechanical rooms, animal rooms, procedure rooms, corridors, and utility spaces, with accompanying photographs of electrical routing equipment. The documents are fully sprinkled and include general notes sections, though the specific details of those notes are not fully visible in the images.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--Remediate Temperature Controls 539-21-108 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
D
Machine Room
A11001
Elevator Room
A11002
GHILMO
8a
J
Kb
Jb
Hb
Nb
Mb Lb
10a
Ga
N
K
Oa
LGR25 11TH FLR
1 2 4
11TH FLR MER
5 6
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/2
/2
:5 :5
A
M -2
-1
ELEVENTH FLOOR PENTHOUSE
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
1-M111
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/16" = 1'-0"
ELEVENTH FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING AUTOMATED LOGIC ROUTER.
FULLY INTEGRATE ALL EXISTING ROUTER POINTS INTO NEW HEAD END THRU JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
5. PROVIDE A STATIC OUTSIDE AIR PROBE (REFERENCE PRESSURE SENSOR) ON A NEW
TOWER MOUNTED TO ROOF ABOVE. SENSOR SHALL BE INSTALLED AT LEAST FIFTEEN
FEET ABOVE ROOF. COORDINATE EXACT LOCATION WITH COR. PROVIDE TUBING TO
COMMUNICATE WITH NEW PRESSURE SENSORS ON EACH FLOOR AS INDICATED.
6. PROVIDE NEW WEATHER STATION NEAR STATIC OUTSIDE AIR PROBE. COORDINATE
EXACT LOCATION WITH COR.
PHOTO - B1-A11001 LGR25 11TH FLR
# DESCRIPTION DATE
D
D
AA.0
AA.1
AB.0
AB.1
AB.2
AC.0
AC.2
AD.0
AE.0
AF.0
DA.0
DB.0
D2.0 D3.0 D4.0 A1.0
BB.0
BD.0
B0.0 B1.0
B2.0
B2.1
B3.0
B4.0
BD.1
A7.0 A7.1
A8.0 B6.1 B7.0
B7.1
B7.2
A1.1 A2.0 A3.0 A3.1 A4.0 A4.1 A5.0 A5.1 A5.2 A6.0
AC.1
CE.0
AD.1
BA.0
BA.1
BB.1
BB.2
BC.1
AG.0
AG.1
AH.0
CA.0
C1.1 C2.1
B6.0
B5.0
BB.3
E0.1
E1.0
F1.0
F2.0
F2.1 F3.0
F4.0
F5.0
F5.1
F6.0
FC.0
FB.0
FA.3
EF.0
EE.0
ED.0
EC.2
EC.0
EB.2
EB.1
EB.0
EE.1
EA.0
E1.1
E2.0 E3.0 E3.1 E4.0 E4.1 E5.0 E5.1
E5.2
E6.0
EC.1
FA.0
FA.1
FA.2
AHU-52 AHU-51
AHU-53
AC.0
AC.2
AD.0
A1.0
B3.0
A1.1 A2.0 A3.0 A3.1
BA.0
2 5
ECBBPMR EXAM/TREATMENT
PMR
EXAM/TREATMENT
PATIENT CARE STORAGE
HOUSEKEEPING CLOSET
STAFF TOILET
PMR
EXAM/TREATMENT0113
TELEHEALTH
/ PMR
EXAM/TREATMENT
ELECTRICAL GEAR
STORAGE
ELEV. MACH. ROOM
TECH CLOSET
PIPE ROOM
DISH MACHINE
HORTICULTURE
THERAPY
OT OFFICE
KILN ROOM
MEDIA
CENTER
RT OFFICE
ACTIVITIES FOR DAILY LIVING - BATH
0117B
0117A
ACTIVITIES
FOR DAILY
LIVING -
KITCHEN
PATIENT WOMEN'S
RCL OFFICE
CLEAN LINEN
RECREATION
GROUP
ROOM
EXERCISE
MAT / PRIVATE RM
PATIENT MEN'S
SOILED LINEN
TECH. (EXISTING)
RCL OFFICE
PT OFFICE
STAIR (EXISTING)
S1.0
PMR EXAM/TREATMENT
PMR EXAM/TREATMENT
ELECTRICAL (EXISTING)
PMR EXAM/TREATMENT
THERAPY SPACE
CORRIDOR
CHANGING / LOCKERS
CORRIDOR
C*B*4
RESIDENT STORAGE
ELEVATOR EQUIP. ROOM
CLOSET
0024A
NURSE EDUC.
EMS LOCKERS
HAC
CORRIDOR
C*B*1
WOMEN
BREAK ROOM
NURSE EDUC.
PHARMACY WORK ROOM
STAIR 2
S*B*2
MECHANICAL VESTIBULE
EMS WORK LEADER
ELEVATOR LOBBY
C*B*5
NFS STORAGE
0018 MEN
CORRIDOR
C*B*3
ELECTRICAL
MECHANICAL
STAIR 1
S*B*1
Corridor-3
C*B*2-3
RT STORAGE
MECHANICAL (EXISTING)
NAE-33
NAE-15
5 2 4
G5RE ROUTER B2 BSMT
4 3
AHU-54
1 2 4
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/2
/2
:5 :5
A
M -2
-1
BUILDING 2 BASEMENT
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
2-M100
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/16" = 1'-0"
BASEMENT FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING AUTOMATED LOGIC ROUTER.
FULLY INTEGRATE ALL EXISTING ROUTER POINTS INTO NEW HEAD END THRU JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
5. REPLACE EXISTING JOHNSON CONTROLS NAE WITH NEW JACE. ALL CONTROLS ROUTED
THRU EXISTING DEVICE SHALL BE RE-ROUTED AND FULLY INTEGRATED THRU NEW JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
PHOTO - B2-0012 NAE-15
PHOTO - B2-0125 G5RE ROUTER B2 BSMT
PHOTO - B2-0125 NAE-33
DN
S T
U V
W
BB CC DD EE
FF
GG
HH
II
JJ
KK
Stairs
S*B*2
Clos.
10D
Elev. Equip.
Lobby
010A
Off.
2A
HR Off
3A
HR Off.
Conference Room
Bathroom
10B
H.A.C.
HR Off.
Electrical
Corridor-4
C*B*2-4
Break Room
1A
Stairs
S*B*1
Pipe Basement
1B
HR Off.
HR Off.
Office
HR Office
Lobby
Corridor-3
C*B*1-3
HR Off.
Vestibule
LGR25 BLDG 3
1 2 4
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/2
/2
:5 :5
A
M -2
-1
BUILDING 3 BASEMENT
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
3-M100
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/8" = 1'-0"
BASEMENT FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING AUTOMATED LOGIC ROUTER.
FULLY INTEGRATE ALL EXISTING ROUTER POINTS INTO NEW HEAD END THRU JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
PHOTO - B3-013 LGR25 BLDG 3
DN
DN
DN
DN
DN
D
N23
Q
R
S
T
U
V
W
XY
5 6
NAE-11
VALVE OVERRIDE SWITCHES
BUILDING 8 BUILDING 13
NAE-10
5 2 4
2 4
LGR BLDG. 13 1 2 4
MONITOR
PC
PRINTER 6
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/2
/2
:5 :5
A
M -2
-1
BUILDING 13 FIRST FLOOR
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
13-M101
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING AUTOMATED LOGIC ROUTER.
FULLY INTEGRATE ALL EXISTING ROUTER POINTS INTO NEW HEAD END THRU JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
5. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING JOHNSON CONTROLS NCE/NIE
DEVICE. ALL CONTROLS ROUTED THRU EXISTING DEVICE SHALL BE REMOVED, RE-
ROUTED AND FULLY INTEGRATED THRU NEW JACE. NCE/NIE DEVICE SHALL REMAIN AS A
FIELD CONTROLLER. FULLY INTEGRATE ALL EXISTING CONTROLLER POINTS INTO NEW
HEAD END THRU JACE. REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
6. REMOVE EXISTING HONEYWELL CONTROLS SYSTEM AFTER ALL POINTS HAVE BEEN
INTEGRATED INTO NEW TRIDIUM SYSTEM.
PHOTO - B13-LGR25 BLDG 13
PHOTO - B13-NAE-10
PHOTO - B13-NAE-11
1 2
C
A
B
2.1
F
D
5.1
E
3.7
ELEC.
G5CE ROUTER BLDG. 14
1 2 4
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/2
/2
:5 :5
A
M -2
-1
BUILDING 14 BASEMENT
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
14-M100
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/8" = 1'-0"
BASEMENT FLOOR PLAN
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING AUTOMATED LOGIC ROUTER.
FULLY INTEGRATE ALL EXISTING ROUTER POINTS INTO NEW HEAD END THRU JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
PHOTO - B14-009 G5CE ROUTER BLDG 14
N
D.1
B
A.1 A
D
123456789
C
MECH. ROOM
B-01
TO
B1
TO
B14 NAE-08 AND NAE-27
1 2 4
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/2
/2
:5 :0
A
M -2
-1
BUILDING 15 BASEMENT
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
15-M100
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/8" = 1'-0"
BASEMENT FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. REPLACE EXISTING JOHNSON CONTROLS NAE'S WITH NEW JACE'S (2x). ALL CONTROLS
ROUTED THRU EXISTING DEVICE SHALL BE RE-ROUTED AND FULLY INTEGRATED THRU
NEW JACE'S. REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE'S. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
PHOTO - B15-B-01 NAE-8 AND NAE-27
D.1
B
A.1 A
D
123456789
C
TO
B14
NAE-35
AHU-31
Clean Procedure Room
111A
Bottle Wash
Vestibule
117A
Animal Room
Animal Room
Animal Room
Animal Room
Animal Room
Animal Room
007 Animal Room
Animal Room
Cage Set Up
103A
Toilet
104C
Clean Procedure Room
Animal Room
Clean Storage
Cage Wash
104A
Cage Dump
Dry Storage
Animal Room
Mechanical
Room
H.A.C.
104B
Necropsy
Clean Corridor
C*1*2
Clean Vestibule
C*1*119A
Lobby
Corridor
C*1*100H
Rack Set-up
Dry Storage
115A
Corridor
C*1*115
Corridor
C*1*116
Clean Corridor
C*1*117
Dirty Corridor
C*1*3
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/2
/2
:5 :0
A
M -2
-1
BUILDING 15 FIRST FLOOR
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
15-M101
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING JOHNSON CONTROLS NCE/NIE
DEVICE. ALL CONTROLS ROUTED THRU EXISTING DEVICE SHALL BE REMOVED, RE-
ROUTED AND FULLY INTEGRATED THRU NEW JACE. NCE/NIE DEVICE SHALL REMAIN AS A
FIELD CONTROLLER. FULLY INTEGRATE ALL EXISTING CONTROLLER POINTS INTO NEW
HEAD END THRU JACE. REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
PHOTO - B15-001 NAE-35
N
File details come from the government source that posted it. Updated .