1-M105 - FIFTH FLOOR.pdf
PDF 2 MB Posted
- Attached to
- Z2DA--Remediate Temperature Controls 539-21-108 Federal contract opportunity
- Solicitation number
- 36C25026B0002
About this file
This document is an architectural floor plan drawing for the Fifth Floor of the Cincinnati VA Medical Center, dated 1/9/2026. The detailed plan shows a comprehensive layout of a medical facility, including numerous specialized rooms such as exam rooms, procedure rooms, offices, staff areas, storage spaces, restrooms, waiting areas, and clinical support spaces like an IV Prep area, Narc. Vault, and Skin and Wound Care Clinic. The drawing is part of a construction document set by Heapy Engineering and Levin Porter Architects, with Kevin Henderson as the Project Manager. The project number is 539-21-108, and the drawing indicates the floor is fully sprinklered. An addendum was issued on 01-12-2026, and the drawing is scaled at 1/16" = 1'-0", providing a comprehensive view of the medical center's fifth-floor layout and room designations.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--Remediate Temperature Controls 539-21-108 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
1-AHU44
AHU-11
AHU-12
Conferece Room
B523
Bath
A521A
Bath
A520A
Stair 2
S*5*2 Clean Linen
A525
Bath
A501A
Staff Tlt
A505
HAC
A503
Stor
A545A
Supp Clos
A567A
Tlt.
A570A
Tlt.
A571A Stor.
A565A
Tlt.
A573A
Exam 2
A571
Exam 6
A567
Exam 7
A566
Exam 1
A572
Staff Physician
A573
Stor.
A563A
Office
A574
Procedure Room
A557D
Exam Room 4
A557A Surgery Office
A557B
Closet
A554A
Waiting Area
A559
Clerk
A559A
Stor.
A551B
Procedure Room
A557C
Stair 5
S*5*5 Tlt.
A553
Telesurgery Office
A554
Closet
A551A Tlt.
A549A Sig. Clos.
A546A
Adm Asst.
A541
Adm. Asst.
A540
Medical Service
B538
Db. Wtr.
A539
B537
Medical
Service Office Office
B537A
Med Svc
B501
Tlt.
B503A Office
B503
Elec.
A546
Rolling Storage
B525 Closet
B526C
Office
B511 Office
B512
Office
B513
Office
B509
Bath
A508A
Storage
B515A
Closet
B507A Storage
B506
Office
B508
Sig. Clos.
B505G
Tlt.
B505A
Stor.
B521D
S.R. Neg. Pressure
A507
S.R. Neg. Pressure
A511
S.R. Neg. Pressure
A512
Bath
A519A
Exam 4
A569
Exam 5
A568
Bath
A522A S.R.
A522
Bath
A517A Bath
A502A
D.R.
A501
D.R.
A526
Nurse Manager
A528
Elec.
A537A
HAC
A562A
B536
Dispensing
Area
Office
B516
Conference Rm.
B507
Office
B514
Nourishment
A513
D.R.
A502
D.R.
A527
Bath
A510A
Bath
A511A
Elec.
A516
Tlt
A579A
Charting
A504
Work Rm.
A549
Exam
A558
Waiting Area
A550Storage
A524
Bath
A509A
Elec.
A514
Bath
A512A
Bath
A518A
Bath
A523A
Nurse Station
A581 Office
A582
Gurney Storage
A578 Pgm. Supp. Asst.
A575
Clos.
A556
Skin and Wound Care Clinic
A551
Chief Office
B540
Office
B539
IV Prep
B526A IV Buff
B526B
Stor.
B518A
Elec.
B521B
Narc. Vault
B521A
Cart Stor.
B535
Office
B518
Office
B515
S.R. Neg. Pressure
A508
Exam 3
A570
Tele
A561Elec.
A560
Service Lobby
A536Bath
A526A
HAC
A535A
Tr. Ch.
A535
Soil
A562
Storage
B505H
Stair 3
S*5*3
Office
B535C
Exam Room 5
A555
Pain Nurse
A563
Class Rm.
A564
Stor.
A564A
D.R.
A520
D.R.
A521
S.R.
A519
HAC
B521E
Staff Tlt.
B535B
Bath
A527A
S.R.
A510
D.R.
A517
Office
B510
Office
B517
Chief
B522 Cleric
B524
Chief Med. Svc.
A542
Inpatient Therapy
A579
S.R.
A509
Omni Cell
A506
Soil. Util.
A515
HAC
A545
Toilet
A577
Stair 1
S*5*1
Office
B504
Compound Picking
B527 IV Ante-Room
B526
Elec.
B505B
Stor
A544
Dirty Equipment
A537B
A537C
Oxygen
Storage
Equipment Room
Clean Supply
A537D
Work Room
A537F
Storage
A537E
Corridor
C*5*3 Corridor
C*5*4
Corridor
C*5*2
Corridor
C*5*1
Corridor
C*5*5
Unit Dose
B535A
D.R.
A523
D.R.
A518
Bath
A507A
NAE-06
ABCDEFGHILMOPQRSTU
4a
8a
16a
16.5
17a
17b
19a
J
Lb.2
Lb.1
Kb
Jb
Ib.1
Ib.2
Hb Fb
Nb
PbQbRbSbTb
Mb Lb
16b
10a
Ga
Ib.3
Ib.5
Ib.7
Ib.8
Ib.10 Ib.12
Ib.14
Ib.16
Ib.18
Ib.19
Ib.20
Ib.21
Ib.22
Ib.23
Ib.24
Ib.25
Ib.26
Ib.27
7a
6a
Ib.28
Ib.29
Ib.4
Ib.17
3a Ib.11Ib.6
N
Fa
K
OaPa
Eb
5TH FLOOR PENTHOUSE (MER)
S
DP
1 2 4
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/9
/2
:0
:1
P
M -2
-1
FIFTH FLOOR
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
1-M105
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/16" = 1'-0"
FIFTH FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING JOHNSON CONTROLS NCE/NIE
DEVICE. ALL CONTROLS ROUTED THRU EXISTING DEVICE SHALL BE REMOVED, RE-
ROUTED AND FULLY INTEGRATED THRU NEW JACE. NCE/NIE DEVICE SHALL REMAIN AS A
FIELD CONTROLLER. FULLY INTEGRATE ALL EXISTING CONTROLLER POINTS INTO NEW
HEAD END THRU JACE. REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
5. PROVIDE SPACE TEMPERATURE AND HUMIDITY SENSOR. COORDINATE EXACT LOCATION
WITH COR.
6. REPLACE BUILDING PRESSURE SENSOR WITH SELF-ZEROING STATIC PRESSURE SENSOR.
PROVIDE TUBING TO COMMUNICATE WITH NEW REFERENCE PRESSURE SENSOR ON 11TH
FLOOR ROOF.
7. REPLACE EXISTING FAN COIL UNIT PNEUMATIC CONTROLS WITH DDC.
8. NOTE OMITTED.
9. REPLACE EIXSTING EXHAUST FAN AND ASSOCIATED DAMPER PNEUMATIC CONTROLS
WITH DDC.
10. REPLACE EXISTING ATU PNEUMATIC CONTROLS WITH DDC.
PHOTO - B1-5TH FLR PHOUSE NAE-06
# DESCRIPTION DATE
1 ADDENDUM 4 01-12-2026
| Sheets |
| 1-M100 - BASEMENT |
| 1-M103 - THIRD FLOOR |
| 1-M104 - FOURTH FLOOR |
| 1-M105 - FIFTH FLOOR |
| 1-M109 - NINTH FLOOR |
| 1-M110 - TENTH FLOOR PENTHOUSE |
| 2-M100 - BUILDING 2 BASEMENT |
| 13-M101 - BUILDING 13 FIRST FLOOR |
| 15-M100 - BUILDING 15 BASEMENT |
| 64-M100 - BUILDING 64 BASEMENT |
| 64-M102 - BUILDING 64 SECOND FLOOR |
| 64-M103 - BUILDING 64 THIRD FLOOR |
| M002 - JOHNSON CONTROLS ROUTER SCHEDULE |
| M004 - TRIDIUM ROUTER SCHEDULE |
| M701 - GENERAL CRITERIA, HONEYWELL CONTROLS REPLACEMENT |
| PG-M101 - PARKING GARAGE FIRST FLOOR PLAN |
File details come from the government source that posted it. Updated .