1-M104 - FOURTH FLOOR.pdf
PDF 8 MB Posted
- Attached to
- Z2DA--Remediate Temperature Controls 539-21-108 Federal contract opportunity
- Solicitation number
- 36C25026B0002
About this file
This document is a Fourth Floor Plan architectural drawing for the Cincinnati VA Medical Center, prepared by Heapy Engineering and Levin Porter Architects. The detailed floor plan shows a comprehensive layout of the fourth floor, including numerous medical and administrative spaces such as exam rooms, offices, laboratories, storage areas, corridors, and specialized facilities like an Oncology Pharmacy Satellite, Infectious Disease Lab, and Hazardous Compounding area. The drawing includes technical details like equipment photos of network and control systems (Tridium AX, NAE-14, NAE-19, NAE-22), grid coordinates, and project metadata including project number 539-21-108, drawing date of 1/9/2026, and an addendum dated 01-12-2026. The plan is drawn at a scale of 1/16" = 1'-0" and is marked as "Fully Sprinklered" with Kevin Henderson as the Project Manager.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--Remediate Temperature Controls 539-21-108 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
D
D
1-AHU29
1-AHU28
1-AHU29
1-AHU28
AHU-13
AHU-9
AHU-10
AHU-24
AHU-22
AHU-32
AHU-25
AHU-23
Mech Room
A456E
Interview
A401 Reception
A400 Dr's Off.
A423A
RAM Lab.
B413B
Stair 4
S*4*4
M. Tlt.
B407
Office
B427
Associate Chief of Staff/Research
B426
CFBRE Off.
B421
Clos.
B425A
Conf.
B425
Adm. Off.
B420B
Tissue Culture
B433A
Mic Rotomy
B435
HSRD Off.
A424D
Stor.
A420
Tlt.
A413A
Tlt.
A410A
D.B.
A457D
Exam
A455
Tlt.
A449A Pharm.
A454
Stair 5
S*4*5
Elec.
A436B
Supp.
A476
Stor.
A436A
Comp. Rm.
A437C
Stor.
A404
Chemo Prep.
A425A
Interview
A402A
Tlt.
A416A Exam Rm. 3
A416
Tlt.
A407A Exam Rm. 4
A407
Med Room
A405
HSRD Office
A422
HSRD Off.
A424A
Dir. Off.
A424B
Common Area
A424C
HSRD Off.
A424G
HSRD Off.
A424F
HSRD Off.
A424E Oncology Pharmacy Sattelite
A425
Elec.
A418A
Stor.
A418
Staff Tlt.
A421
Tlt.
A414A Exam Rm. 7
A414
Exam Rm. 8
A409
Tlt.
A408A
Tlt.
A406A
Waiting
A402B
IRM Storage (Comm)
A445A
KIT.
A475
CL. Lin.
A462
Soil. Util.
A461
Exam
A474 Tlt.
A473A
Tlt.
A471A Exam 5
A471
Tlt.
A470A
Exam 9
A469
Exam 10
A468
Tlt.
A467A
Exam 6
A466
Tlt.
A465A
Exam 2
A464
Tlt.
A464A
Exam
A458C
Stor.
A460
Exam
A458B
Exam
A458A
Sub. Lab.
A453
Exam
A458
Tlt.
A457H Proc.
A457E
Tlt.
A457C
Elec.
A456
S.B.
A457B
Stor.
A457A
GCRC Corridor
A457
Res. Off.
A442
Neuro. Res.
A442A
Chief Rm.
A441
Computer Off.
A440
IRM Network Operation Center
A437
Tlt.
A439A
Staff Physician
B403A
Neuro Office
B439
Comp. Programmer Off.
A439
Office
B437
Microscope Core
B436
Corridor
B429A Sig. Clos.
B416
Electrophoresis Core
B413A
Ram Lab.
B412A
HAC
B409 F. Tlt.
B406
Cold Rm.
B415A
Office
B426A
Comp. Specialist Off.
A431
Service Lobby
A436
Trash Chute
A435
Exam 1
A473
Office
B412C
Comp. Training
A430
Regular E.E.G
B403B
E.E.G. Control & Observation
B403
Copier Room
B437A
IRM Office
A427
Toilet
A446Elec.
A445
Toilet
A446A
Exam
A463
Tlt.
A463A
Freez.
B415B
Elec.
B431
Refrig.
B430
Office
B428
Director's Office
B429B
Tlt.
A474A
Stair 2
S*4*2
Exam Rm. 11
A412
Exam Rm. 12
A411
Social Worker
A422A
Tissue Culture
B412B W. Lab.
B412
Exam Rm. 9
A413
Exam Rm. 10
A410
Exam Rm. 5
A415
Exam Rm. 6
A408
Exam Rm. 1
A417
Exam Rm. 2
A406
Elec.
A424H
HAC
A403
IRM Storage (Hdwr)
A444
HAC
A477
Elec.
A459
Exam 3
A472
Exam 4
A465
Exam 7
A470
Exam 8
A467
Stair 1
S*4*1
Evoked Potential Lab
B438
Elec.
B410
Elec.
B417
HAC
B429
Research Adm. Off.
B420
Auto-Clave / Dishwasher
B408 LAB. Procedure Rm
B411
Stor.
A444A
Corridor
C*4*3
Corridor
C*4*4
Corridor
C*4*1
Corridor
C*4*6
Waiting
A478Interview
A401A
HSRD Off.
A424I
HSRD Off.
A424
Infectious Disease Lab
B414
Office
B415
Non-Hazardous Compounding
B414D
Hazardous Compounding
B414B Ante Room
B414C
Hazardous Storage
B414A
Work Station Area
B414
Corridor
C*4*5
Lab
B432
Reception
A401B
Corridor
C*4*2
Stair 3
S*4*3
Lab.
A457G
Nurse Station
A457F Dr's Off.
A423
NAE-14
NAE-19
TRIDIUM
AX
NAE-22
ABCDEFGHILMOPQRSTU
4a
8a
16a
16.5
17a
17b
19a
J
Lb.2
Lb.1
Kb
Jb
Ib.1
Ib.2
Hb Fb
Nb
PbQbRbSbTb
Mb Lb
16b
10a
Ga
Ib.3
Ib.5
Ib.7
Ib.8
Ib.10 Ib.12
Ib.14
Ib.16
Ib.18
Ib.19
Ib.20
Ib.21
Ib.22
Ib.23
Ib.24
Ib.25
Ib.26
Ib.27
7a
6a
Ib.28
Ib.29
Ib.4
Ib.17
3a Ib.11Ib.6
N
Fa
K
OaPa
Eb
4TH FLOOR PENTHOUSE
G5RE ROUTER BLDG. 1-AH10
4 2 1
S
DP
S
LGR25-1-4 BLD 1 ON 4TH FLR
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/9
/2
:0
:1
P
M -2
-1
FOURTH FLOOR
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
1-M104
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/16" = 1'-0"
FOURTH FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING AUTOMATED LOGIC ROUTER.
FULLY INTEGRATE ALL EXISTING ROUTER POINTS INTO NEW HEAD END THRU JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
5. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING JOHNSON CONTROLS NCE/NIE
DEVICE. ALL CONTROLS ROUTED THRU EXISTING DEVICE SHALL BE REMOVED, RE-
ROUTED AND FULLY INTEGRATED THRU NEW JACE. NCE/NIE DEVICE SHALL REMAIN AS A
FIELD CONTROLLER. FULLY INTEGRATE ALL EXISTING CONTROLLER POINTS INTO NEW
HEAD END THRU JACE. REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
6. PROVIDE SPACE TEMPERATURE AND HUMIDITY SENSOR. COORDINATE EXACT LOCATION
WITH COR.
7. REPLACE BUILDING PRESSURE SENSOR WITH SELF-ZEROING STATIC PRESSURE SENSOR.
PROVIDE TUBING TO COMMUNICATE WITH NEW REFERENCE PRESSURE SENSOR ON 11TH
FLOOR ROOF.
8. REPLACE EXISTING NIAGARA AX JACE WITH NEW N4 JACE. INTEGRATE ALL EXISTING
CONTROLS INTO NEW SYSTEM.
9. PROVIDE SENSOR TO MONITOR SPACE TEMPERATURE. CRITICAL ALARM SHALL BE SENT
TO ECC IF ROOM REACHES 80 DEGREES (ADJUSTABLE).
10. REMOVE EXISTING PNEUMATIC CONTROLS COMPRESSOR AND ASSOCIATED PNEUMATIC
CONTROLS COMPONENTS ONCE VERIFIED THAT NO SYSTEMS ARE RELIANT UPON THESE
COMPONENTS. SHUT COMPRESSOR DOWN FOR 4 WEEKS PRIOR TO REMOVAL FOR
VERIFICATION. COORDINATE CLOSELY WITH COR.
11. REMOVE EXISTING HONEYWELL CONTROLS PANEL AND ALL ASSOCIATED COMPONENTS
AFTER ALL POINTS HAVE BEEN INTEGRATED INTO NEW TRIDIUM SYSTEM. THIS SCOPE
SHALL NOT BE EXECUTED UNTIL VERIFICATION THAT NO SYSTEMS ARE RELIANT UPON
THESE COMPONENTS. COORDINATE CLOSELY WITH COR. REMOVE ELECTRIC BACK TO
SOURCE.
12. REPLACE EXISTING JOHNSON CONTROLS NAE WITH NEW JACE. ALL CONTROLS ROUTED
THRU EXISTING DEVICE SHALL BE RE-ROUTED AND FULLY INTEGRATED THRU NEW JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
PHOTO - B1-A436B NAE-14
PHOTO - B1-A456E G5RE ROUTER BLDG1-AH10
PHOTO - B1-A456E NAE-19
PHOTO - B1-A456E NAE-22
PHOTO - B1-A436B TRIDIUM AX
PHOTO - B1-A436B LRG25-1-4 BLD 1 4TH FLR
# DESCRIPTION DATE
1 ADDENDUM 4 01-12-2026
| Sheets |
| 1-M100 - BASEMENT |
| 1-M103 - THIRD FLOOR |
| 1-M104 - FOURTH FLOOR |
| 1-M105 - FIFTH FLOOR |
| 1-M109 - NINTH FLOOR |
| 1-M110 - TENTH FLOOR PENTHOUSE |
| 2-M100 - BUILDING 2 BASEMENT |
| 13-M101 - BUILDING 13 FIRST FLOOR |
| 15-M100 - BUILDING 15 BASEMENT |
| 64-M100 - BUILDING 64 BASEMENT |
| 64-M102 - BUILDING 64 SECOND FLOOR |
| 64-M103 - BUILDING 64 THIRD FLOOR |
| M002 - JOHNSON CONTROLS ROUTER SCHEDULE |
| M004 - TRIDIUM ROUTER SCHEDULE |
| M701 - GENERAL CRITERIA, HONEYWELL CONTROLS REPLACEMENT |
| PG-M101 - PARKING GARAGE FIRST FLOOR PLAN |
File details come from the government source that posted it. Updated .