This document is a ninth floor architectural floor plan for the Cincinnati VA Medical Center, prepared by Heapy Engineering and Levin Porter Architects. The detailed blueprint shows a comprehensive layout of the floor, including numerous room types such as psychological offices, sleep rooms, administrative spaces, toilets, storage areas, break rooms, electrical closets, and corridors. The drawing includes a grid system, room labels, and technical annotations, with the project number 539-21-108 and a project date of 1/9/2026. The plan is marked as fully sprinklered and includes a small technical photograph of equipment in the bottom right corner, with an addendum noted on 01-12-2026. The floor plan is drawn to a scale of 1/16" = 1'-0" and is part of construction documents for the U.S. Department of Veterans Affairs.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--Remediate Temperature Controls 539-21-108 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
AHU-8
AHU-7
Stair 2
S*9*2
Elec.
A916D
Clos.
A919C
Adm. Asst.
A920 Psych. Off.
A919A
Psych. Off.
A919B
Clos.
A907 Clos.
A904B
Elec.
A904C
AFGE
A904
Lin.
A918
HAC
A917
Psych. Off.
A922 Chief Psych.
A921
Entry
A938
Toilet
A938B
Toilet
A938D
Sleep 5
A938A Tlt.
A937B
Tlt.
A939B
Tlt.
A937D
Sleep 2
A937C
Elec.
A941B Soiled Utility
A941A
Stair 5
S*9*5
Clean Supply
A942
Tlt.
A939D
Lead Tech./2nd Tech.
A935A
Sleep 3
A939C
Sleep 1
A937A
Break Room
A941
Shower
A939E
Crash Cart
C-9-3A
Bath
A906C
Clos.
A906B Entry
A906A AFGE
A906
AFGE
A905A
Break Room
A909
Office
A908
Vol. Serv. Office
A905
Clos.
A912A
Vol. Serv. Storage
A911
ONA Local 105
A911A Office
A914
Psych. Off.
A902
M. Tlt.
A901
Office
A915
Serv. Lobby
A916
Trash Chute
A915A
Psych. Off.
A901A
F. Tlt.
A946
Electrical Closet
A931A
Sig. Clos.
A929
Psych. Off.
A919
Adm. Asst.
A926
D. Wtr. Mech. Area
A923
Psych. Off.
B907
Clerk
A924
Psych. Off.
B906
Office
B901
Psych. Conf. Rm.
B903
Psych. Lab.
A903B
Psych. Off
A903
HAC
A915B Office
A913
Stor. Rm.
A916A
Res.
B905A
Sdm. Off.
A925
Sleep Phy.
A934
Sleep Nurses/Fellows
A935
Sleep 4
A939AControl Rm.
A940
Tlt.
A909A
Psych.
A904A Psych. Lab.
A903A
Clst.
A941C
Stor.
A918B
Stair 1
S*9*1
Chief Psych. Off.
A927
Corridor
C*8*3
Psych. Off.
B902
Copy Room
B905
Fan Rm.
B904
Stor.
A918A
Chief Office
A944
Corridor
C*9*3
Waiting
A932
Off.
A945
Dir. Off.
A946A Exam 2
A943
Corridor
C*9*2
Exam 1
A933
Corridor
C*9*1
Office
A912
Sleep 6
A938C
NAE-07
NIAGRA
AX
ABCDEFGHILMOPQRSTU
4a
8a
16a
16.5
17a
17b
19a
J
Lb.2
Lb.1
Kb
Jb
Ib.1
Ib.2
Hb Fb
Nb
PbQbRbSbTb
Mb Lb
16b
10a
Ga
Ib.14
Ib.22
Ib.23
Ib.24
Ib.27
7a
6a
Ib.28
Ib.29
3a
N
Fa
K
OaPa
Eb
S
DP
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/9
/2
:0
:2
P
M -2
-1
NINTH FLOOR
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
1-M109
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/16" = 1'-0"
NINTH FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING JOHNSON CONTROLS NCE/NIE
DEVICE. ALL CONTROLS ROUTED THRU EXISTING DEVICE SHALL BE REMOVED, RE-
ROUTED AND FULLY INTEGRATED THRU NEW JACE. NCE/NIE DEVICE SHALL REMAIN AS A
FIELD CONTROLLER. FULLY INTEGRATE ALL EXISTING CONTROLLER POINTS INTO NEW
HEAD END THRU JACE. REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
5. PROVIDE SPACE TEMPERATURE AND HUMIDITY SENSOR. COORDINATE EXACT LOCATION
WITH COR.
6. REPLACE EXISTING NIAGARA AX JACE WITH NEW N4 JACE. INTEGRATE ALL EXISTING
CONTROLS INTO NEW SYSTEM.
7. PROVIDE SELF-ZEROING BUILDING PRESSURE SENSOR. COORDINATE EXACT LOCATION
WITH COR. PROVIDE TUBING TO COMMUNICATE WITH NEW REFERENCE PRESSURE
SENSOR ON 11TH FLOOR ROOF.
8. REMOVE EXISTING HONEYWELL CONTROLS PANEL AND ALL ASSOCIATED COMPONENTS
AFTER ALL POINTS HAVE BEEN INTEGRATED INTO NEW TRIDIUM SYSTEM. THIS SCOPE
SHALL NOT BE EXECUTED UNTIL VERIFICATION THAT NO SYSTEMS ARE RELIANT UPON
THESE COMPONENTS. COORDINATE CLOSELY WITH COR. REMOVE ELECTRIC BACK TO
SOURCE.
PHOTO - B1-A916d TRIDIUM AX
# DESCRIPTION DATE
1 ADDENDUM 4 01-12-2026
| Sheets |
| 1-M100 - BASEMENT |
| 1-M103 - THIRD FLOOR |
| 1-M104 - FOURTH FLOOR |
| 1-M105 - FIFTH FLOOR |
| 1-M109 - NINTH FLOOR |
| 1-M110 - TENTH FLOOR PENTHOUSE |
| 2-M100 - BUILDING 2 BASEMENT |
| 13-M101 - BUILDING 13 FIRST FLOOR |
| 15-M100 - BUILDING 15 BASEMENT |
| 64-M100 - BUILDING 64 BASEMENT |
| 64-M102 - BUILDING 64 SECOND FLOOR |
| 64-M103 - BUILDING 64 THIRD FLOOR |
| M002 - JOHNSON CONTROLS ROUTER SCHEDULE |
| M004 - TRIDIUM ROUTER SCHEDULE |
| M701 - GENERAL CRITERIA, HONEYWELL CONTROLS REPLACEMENT |
| PG-M101 - PARKING GARAGE FIRST FLOOR PLAN |
File details come from the government source that posted it. Updated .