2-M100 - BUILDING 2 BASEMENT.pdf
PDF 4 MB Posted
- Attached to
- Z2DA--Remediate Temperature Controls 539-21-108 Federal contract opportunity
- Solicitation number
- 36C25026B0002
About this file
This architectural floor plan is for Building 2 Basement at the Cincinnati VA Medical Center, drawn by Heapy Engineering and Levin Porter Architects. The detailed basement floor plan shows multiple specialized rooms including patient care areas (PMR Exam/Treatment, Women's and Men's Patient Rooms), therapy spaces (Horticulture Therapy, Activities for Daily Living), support areas (Clean/Soiled Linen, Storage, Pharmacy Work Room), and infrastructure spaces (Mechanical, Electrical, Elevator Rooms). The drawing is dated January 9, 2026, with Project No. 539-21-108 and is marked as fully sprinklered. The plan includes grid coordinates, room numbers, and three side photographs of electrical equipment/routing panels. The document represents a construction document for a VA medical facility renovation or new construction project.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--Remediate Temperature Controls 539-21-108 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
D
AA.0
AA.1
AB.0
AB.1
AB.2
AC.0
AC.2
AD.0
AE.0
AF.0
DA.0
DB.0
D2.0 D3.0 D4.0 A1.0
BB.0
BD.0
B0.0 B1.0
B2.0
B2.1
B3.0
B4.0
BD.1
A7.0 A7.1
A8.0 B6.1 B7.0
B7.1
B7.2
A1.1 A2.0 A3.0 A3.1 A4.0 A4.1 A5.0 A5.1 A5.2 A6.0
AC.1
CE.0
AD.1
BA.0
BA.1
BB.1
BB.2
BC.1
AG.0
AG.1
AH.0
CA.0
C1.1 C2.1
B6.0
B5.0
BB.3
E0.1
E1.0
F1.0
F2.0
F2.1 F3.0
F4.0
F5.0
F5.1
F6.0
FC.0
FB.0
FA.3
EF.0
EE.0
ED.0
EC.2
EC.0
EB.2
EB.1
EB.0
EE.1
EA.0
E1.1
E2.0 E3.0 E3.1 E4.0 E4.1 E5.0 E5.1
E5.2
E6.0
EC.1
FA.0
FA.1
FA.2
AHU-52 AHU-51
AHU-53
AC.0
AC.2
AD.0
A1.0
B3.0
A1.1 A2.0 A3.0 A3.1
BA.0
2 5
PMR EXAM/TREATMENT
PMR
EXAM/TREATMENT
PATIENT CARE STORAGE
HOUSEKEEPING CLOSET
STAFF TOILET
PMR
EXAM/TREATMENT0113
TELEHEALTH
/ PMR
EXAM/TREATMENT
ELECTRICAL GEAR
STORAGE
ELEV. MACH. ROOM
TECH CLOSET
PIPE ROOM
DISH MACHINE
HORTICULTURE
THERAPY
OT OFFICE
KILN ROOM
MEDIA
CENTER
RT OFFICE
ACTIVITIES FOR DAILY LIVING - BATH
0117B
0117A
ACTIVITIES
FOR DAILY
LIVING -
KITCHEN
PATIENT WOMEN'S
RCL OFFICE
CLEAN LINEN
RECREATION
GROUP
ROOM
EXERCISE
MAT / PRIVATE RM
PATIENT MEN'S
SOILED LINEN
TECH. (EXISTING)
RCL OFFICE
PT OFFICE
STAIR (EXISTING)
S1.0
PMR EXAM/TREATMENT
PMR EXAM/TREATMENT
ELECTRICAL (EXISTING)
PMR EXAM/TREATMENT
THERAPY SPACE
CORRIDOR
CHANGING / LOCKERS
CORRIDOR
C*B*4
RESIDENT STORAGE
ELEVATOR EQUIP. ROOM
CLOSET
0024A
NURSE EDUC.
EMS LOCKERS
HAC
CORRIDOR
C*B*1
WOMEN
BREAK ROOM
NURSE EDUC.
PHARMACY WORK ROOM
STAIR 2
S*B*2
MECHANICAL VESTIBULE
EMS WORK LEADER
ELEVATOR LOBBY
C*B*5
NFS STORAGE
0018 MEN
CORRIDOR
C*B*3
ELECTRICAL
MECHANICAL
STAIR 1
S*B*1
Corridor-3
C*B*2-3
RT STORAGE
MECHANICAL (EXISTING)
NAE-33
NAE-15
5 2 4
G5RE ROUTER B2 BSMT
4 3
AHU-54
1 2 4
P ro je ct
N o.
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
E
D
C
B
A
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Manager
Cincinnati V.A Medical Center
U.S. Department of Veterans Affairs
F
Phase
ARCHITECT/ENGINEER OF RECORDCONSULTANT
32 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLEREDKEVIN HENDERSONPROJECT NO. STATE COA FIRM NO.
/9
/2
:0
:2
P
M -2
-1
BUILDING 2 BASEMENT
10/23/25 GSE WJS
REMEDIATE TEMPERATURE
CONTROLS
2-M100
539-21-108
CINCINNATI, OHIO
2020-05099 01528
SCALE: 1/16" = 1'-0"
BASEMENT FLOOR PLAN N
PLAN NOTES
GENERAL NOTES
A. REFER TO SHEET M001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
1. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING AUTOMATED LOGIC ROUTER.
FULLY INTEGRATE ALL EXISTING ROUTER POINTS INTO NEW HEAD END THRU JACE.
REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
2. EXTEND 120V ELECTRIC FROM EXISTING PANEL TO NEW PANEL.
3. PROVIDE CVAMC STANDARD DUAL DATA DROP IN SURFACE MOUNT OUTLET FOR NEW
JACE. PROVIDE NEW PATCH PANEL IN THE CLOSEST EXISTING RACK WITH CAPACITY,
WITHIN DISTANCE LIMITS, TERMINATE NEW DATA CABLING. COORDINATE WITH OIT.
4. REPLACE LOCK IN EXISTING PANEL. ALL PANELS SHALL BE KEYED ALIKE.
5. PROVIDE NEW JACE BACNET ROUTER NEXT TO EXISTING JOHNSON CONTROLS NCE/NIE
DEVICE. ALL CONTROLS ROUTED THRU EXISTING DEVICE SHALL BE REMOVED, RE-
ROUTED AND FULLY INTEGRATED THRU NEW JACE. NCE/NIE DEVICE SHALL REMAIN AS A
FIELD CONTROLLER. FULLY INTEGRATE ALL EXISTING CONTROLLER POINTS INTO NEW
HEAD END THRU JACE. REFER TO M00 SERIES SHEETS FOR APPROXIMATE QUANTITIES.
PHOTO - B2-0012 NAE-15
PHOTO - B2-0125 G5RE ROUTER B2 BSMT
PHOTO - B2-0125 NAE-33
# DESCRIPTION DATE
1 ADDENDUM 4 01-12-2026
| Sheets |
| 1-M100 - BASEMENT |
| 1-M103 - THIRD FLOOR |
| 1-M104 - FOURTH FLOOR |
| 1-M105 - FIFTH FLOOR |
| 1-M109 - NINTH FLOOR |
| 1-M110 - TENTH FLOOR PENTHOUSE |
| 2-M100 - BUILDING 2 BASEMENT |
| 13-M101 - BUILDING 13 FIRST FLOOR |
| 15-M100 - BUILDING 15 BASEMENT |
| 64-M100 - BUILDING 64 BASEMENT |
| 64-M102 - BUILDING 64 SECOND FLOOR |
| 64-M103 - BUILDING 64 THIRD FLOOR |
| M002 - JOHNSON CONTROLS ROUTER SCHEDULE |
| M004 - TRIDIUM ROUTER SCHEDULE |
| M701 - GENERAL CRITERIA, HONEYWELL CONTROLS REPLACEMENT |
| PG-M101 - PARKING GARAGE FIRST FLOOR PLAN |
File details come from the government source that posted it. Updated .