Attachment 12 - Drawings Vol 3.pdf
PDF 25 MB Posted
- Solicitation number
- 36C77625R0092-RFP
About this file
This file is a collection of architectural and engineering drawings for the EHRM Infrastructure Upgrades Construction project at James A. Haley Veterans Hospital in Tampa, Florida (VA Project 673-20-107). The drawings, issued for construction on 04/04/2025, cover multiple trailer buildings (73-83 and 99) and include existing condition plans, demolition plans, new work plans, mechanical systems, electrical systems, plumbing, fire protection, and technology infrastructure. The project involves creating new telecommunication rooms (TRs) and technology equipment (TE) cabinets across multiple trailers, with specific locations including TE 74-105, TE 75-105, TE 76-105, TE 78-107, TE 80-125, TE 81-103, TE 82-103, and TE 83-131. The architect of record is CB Design Group (Alexandria, VA), with mechanical, electrical, and structural engineering by Scott Przybysz/IMEG Corporation (St. Louis, MO), and additional consultants including Mark Dyck (Martinsburg, WV), Clare Kramer (Orlando, FL), and Compass (Novelty, OH).
The project scope encompasses demolition of existing walls, doors, fixtures, and infrastructure; installation of new partitions with fire-rated construction; flooring and finishes; mechanical systems including split-unit air conditioning and temperature/humidity sensors; electrical systems with receptacles, circuit breakers, and lighting; and technology infrastructure including Category 6A cabling, equipment racks, network switches, UPS systems, and fire-rated telephone terminal boards. New work includes exposed structure above TRs with 2-hour fire-resistive spray application, suspended lighting fixtures, lay-in ceiling tiles, and static-dissipating flooring in designated areas. The Contracting Officer is Sean Kaminski (SCC, Division Chief, Department of Veterans Affairs Contracting, Independence, OH), with Marco Lopez serving as the Contracting Officer Representative (COR) at the hospital facility.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HANDICAPP ED RAMP
FDOT IND EX #304
HANDICAPP ED RAMP
FDOT IND EX #304
CONCRETE
33.17
S-2
TRASH
DS-BL
EXIT
ENTER
POST
POST
POST
POST
ISLAND
ISLAND
TO P OF W ALL
D
WM
EE
MACHINE ROOM
ELEVATOR
2 ' - 0 "
EX B03
' - 0
E X
B0
UP
B R
U C
E B
D
O W
N S
B L
V D
E FLETCHER AVE
UNIVERSITY OF SOUTH
FLORIDA COLLEGE
E 132ND AVE
N
N
D S
T
N
R
D S
T
L
IV
IN
G
S T
O N
A V
E
N
T
H S
T
N
T
H S
T
E 131ST AVE
E 131ST AVE
B R
U C
B
D
O W
N S
B L
V D
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
LTCAL
EHRM INFRASTRUCTURE UPGRADES
TAMPA, FL.
ISSUED FOR CONSTRUCTION
COVER SHEET- VOLUME 3
GI-300
-2
-1
G I-
.p d f
Department of Veterans Affairs
673-20-107 EHRM INFRASTRUCTURE UPGRADES- VOL 3
ISSUED FOR CONSTRUCTION
PROJECT DIRECTORY
Medical Center Director
Director of Facility Management Service
Medical Director
Project COR
Project CO
Infection Control
Safety Officer
CONTRACTING OFFICER REPRESENTATIVE (COR)
Marco Lopez
James A. Haley Veteran Hospital 13000 Bruce B. Downs Blvd Tampa, FL 33612
PHONE: (813) 972-2000
Marco.Lopez@va.gov
ARCHITECT
CB DESIGN GROUP, INC
412 King St. Ste. 301 Alexandria, VA 22314
PHONE: (888) 585-CBDG (2234)
wbridge@cbdg-ae.com
MEP/FP/STRUCTURAL ENGINEER
Scott Przybysz
IMEG Corporation 15 Sunnen Drive Ste. 104 St. louis, MO 63143
PHONE: (314) 951-2535
scott.r.przybysz@imegcorp.com
CONTRACTING OFFICER (CO)
Sean Kaminski
Contracting Officer SCC, Division Chief Department of Veterans Affairs | Contracting 6150 Oak Tree Blvd Suite 490 Independence, OH 44131
PHONE: (216) 447-8300
Sean.Kaminski@va.gov
APPROVALS
JAMES A. HALEY VETERAN HOSPITAL
13000 BRUCE B. DOWNS BLVD
TAMPA, FL. 33612
N
PLAN
NORTHSCALE: NOT TO SCALE
VICINITY MAP
OFFICE AREA
OFFICE
OFFICE
RESTROOM
STORAGE
OFFICE
OFFICE
101-T73
102-T73
103-T73
104-T73
105-T73
106-T73
107-T73
EXISTING CONDITIONS- GENERAL NOTES
1. EXISTING CONDITION DRAWINGS ARE FOR REFERENCE ONLY. CONTRACTOR SHALL
VERIFY LOCATION OF ALL ITEMS SHOWN ON THIS SHEET PRIOR TO BEGINNING OF WORK.
EXISTING WALL RATING LEGEND
3 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
EXISTING WALL RATING- GENERAL NOTES
1. ALL EXISTING FIRE RATINGS SHOWN HAVE BEEN PROVIDED BY THE VA. CONTRACTOR
SHALL FIELD VERIFY ALL EXISTING PARTITIONS WHERE WORK IS BEING PERFORMED AND
SEAL ALL PENETRATIONS THROUGH ALL FLOOR AND FIRE RATED BARRIERS WITH UL
LISTED ASSEMBLIES TO MAINTAIN FIRE RATED BARRIERS IN PLACE
2. SEE LIFE SAFETY SHEETS FOR DETAILED LIFE SAFETY PLANS.
EXISTING TELECOM
ROOM LOCATION
PLAN LEGEND
NEW TELECOM ROOM/TE
CABINET LOCATION
NOTE: BUILDING 73 SHALL BE FED FROM BUILDING 74. THERE IS NO ARCHITECTURAL
WORK PROPOSED ON THIS LEVEL- SEE ALL CONSULTANTS' SHEETS FOR WORK
THAT IS PROPOSED ON THIS LEVEL.
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
LTCAL
EHRM INFRASTRUCTURE UPGRADES
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 73 - EXISTING CONDITION
PLAN - OVERALL FIRST FLOOR
73-GC101
-2
-1
-G
C
/1
/2
.p d f
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
1/4" = 1'-0"A10
TRAILER 73 - EXISTING CONDITION - 1ST FLOOR N
PLAN
NORTH
N
TRUE
NORTH
H T
OFFICE AREA
COMM
RESTROOM
OFFICE
OFFICE
OFFICE
OFFICE
101-T75
105-T75
104-T75
103-T75
102-T75 107-T75
106-T75
H T
RESTROOM
H T
OFFICE AREA
RESTROOM
STORAGE
OFFICE
OFFICE
OFFICE
OFFICE
101-T76
104-T76
105-T76
103-T76
102-T76 107-T76
106-T76
H T
NEW TE
74-105
PROVIDE TEMPERATURE AND HUMIDITY SENSORS FOR
ALL TELECOMMUNICATION SPACES INCLUDING
LOCATIONS WITH TE CABINETS INSTALLED. SENSORS
SHALL CONNECT TO CAMPUS FACILITY MANAGEMENT
CONTROL SYSTEM (FMCS) FOR SPACE MONITORING
ONLY.
SSU-T74105
CU-T74105
ROUTE 3/4"DPP DN AND
CONNECT WITH P-TRAP OF
LAVATORY.
REF
PROVIDE TEMPERATURE AND HUMIDITY SENSORS FOR ALL
TELECOMMUNICATION SPACES INCLUDING LOCATIONS WITH TE
CABINETS INSTALLED. SENSORS SHALL CONNECT TO CAMPUS
FACILITY MANAGEMENT CONTROL SYSTEM (FMCS) FOR SPACE
MONITORING ONLY.
SSU-T75105
CU-T75105
ROUTE 3/4"DPP DN AND
CONNECT WITH P-TRAP
OF LAVATORY.
REF
PROVIDE TEMPERATURE AND HUMIDITY SENSORS FOR ALL
TELECOMMUNICATION SPACES INCLUDING LOCATIONS WITH TE
CABINETS INSTALLED. SENSORS SHALL CONNECT TO CAMPUS
FACILITY MANAGEMENT CONTROL SYSTEM (FMCS) FOR SPACE
MONITORING ONLY.
SSU-T78107
CU-T78107
ROUTE 3/4"DPP DN AND
CONNECT WITH P-TRAP OF
LAVATORY.
REF
PROVIDE TEMPERATURE AND HUMIDITY SENSORS
FOR ALL TELECOMMUNICATION SPACES INCLUDING
LOCATIONS WITH TE CABINETS INSTALLED. SENSORS
SHALL CONNECT TO CAMPUS FACILITY MANAGEMENT
CONTROL SYSTEM (FMCS) FOR SPACE MONITORING
ONLY.
SSU-T76105
CU-T76105
ROUTE 3/4"DPP DN AND
CONNECT WITH P-TRAP
OF LAVATORY.
REF
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
950 N. WASHINGTON ST
SUITE 334
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
DRAWINGS NOT INTENDED FOR
CONSTRUCTION.
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
BHAACHRUSARN
EHRM INFRASTRUCTURE UPGRADE
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 73 TO 78 - OVERALL
FIRST FLOOR PLAN -
MECHANICAL
T70-MH101
-2
-1
T -M
H
/0
/2
.p d f
N O R
HT
1/8" = 1'-0"
TRAILER 74 - OVERALL FIRST FLOOR PLAN - MECHANICAL
1 N
O R
HT
1/8" = 1'-0"
TRAILER 75 - OVERALL FIRST FLOOR PLAN - MECHANICAL
N O R
HT
1/8" = 1'-0"
TRAILER 78 - OVERALL FIRST FLOOR PLAN - MECHANICAL
N O R
HT
1/8" = 1'-0"
TRAILER 76 - OVERALL FIRST FLOOR PLAN - MECHANICAL
COMM
RESTROOM
OFFICE
OFFICE
OFFICE
OFFICE
101-T75
105-T75
104-T75
103-T75
102-T75 107-T75
106-T75
E
RESTROOM
E
OFFICE AREA
RESTROOM
STORAGE
OFFICE
OFFICE
OFFICE
OFFICE
101-T76
104-T76
105-T76
103-T76
102-T76 107-T76
106-T76
E
E
E
{LS1}
E
E
{LS1}
E
E
{LS1}
E
E
{LS1}
NEW TE
74-105
T70-EP101
A7
CU-T74105DS-CU-T74105 4
T70-EP101
A10
CU-T75105DS-CU-T75105 4
T70-EP101
A16
CU-T78107 4DS-CU-T78107
T70-EP101
A13
CU-T76105DS-CU-T76105 4
NEW TE
78-107
+48"
AC-SCP-1
SSU-T78107
MX-SSU-T78107
F1F1
O
NEW TE
74-105
AC-SCP-1
SSU-T74105
MX-SSU-T74105
F1F1
O
NEW TE
75-105
+48"
AC-SCP-1
SSU-T75105
MX-SSU-T75105
F1F1
O
NEW TE
76-105
+48"
AC-SCP-1
SSU-T76105
MX-SSU-T76105
F1F1
O
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
DRAWINGS NOT INTENDED FOR
CONSTRUCTION.
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
SSYHND
EHRM INFRASTRUCTURE UPGRADE
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 73 TO 78 - OVERALL FIRST
FLOOR PLAN - ELECTRICAL
T70-EP101
-2
-1
T -E
P
/2
/2
.p d f
1/8" = 1'-0"
TRAILER 74 - OVERALL FIRST FLOOR PLAN - ELECTRICAL
D9
1/8" = 1'-0"
TRAILER 75 - OVERALL FIRST FLOOR PLAN - ELECTRICAL
G91/8" = 1'-0"
TRAILER 78 - OVERALL FIRST FLOOR PLAN - ELECTRICAL
G16
N
BUILDING
NORTH
N
TRUE
NORTH
GENERAL NOTES:
1. CONTRACTOR SHALL REFER TO SHEET 0-E001,
0-E002, 0-E003, 0-E501, 0-E502, 0-E601 AND 0-
E701 FOR LEGENDS, SCHEDULES, DETAILS,
NOTES AND OTHER GENERAL INFORMATION.
2. CONTRACTOR IS PERMITTED TO ADJUST
LAYOUT AS NECESSARY TO ACCOMMODATE
OTHER SYSTEMS AND COORDINATE WITH
EXISTING DUCT WORK. GENERAL LOCATION
SHALL BE MAINTAINED. DO NOT MOUNT
LUMINAIRES TO THE DUCT WORK. MOUNT
LUMINAIRE SUCH THAT SHADOWS ARE NOT
CAST.
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
777874
KEYNOTES:
1. INSTALL RECEPTACLES FOR PDU AND UPS ON
WALL BEHIND RACK, ALIGNED WITH THE
CUTOUT ON THE TELECOMMUNICATIONS
ENCLOSURE.
2. CIRCUIT NEW RECEPTACLES IN THIS SPACE TO
NEAREST PANEL, PROVIDE 2#12 & 1#12 EGC IN
3/4"C.
3. CIRCUIT NEW ACCESS CONTROL PANEL TO
NEAREST PANEL, PROVIDE 2#12 & 1#12 EGC IN
3/4"C.
4. CIRCUIT NEW CONDENSING UNIT IN THIS
SPACE TO NEAREST PANEL, PROVIDE 30A/2P
CIRCUIT BREAKER WITH 2#10 & 1#10 EGC IN
3/4"C.
5. SPLIT SYSTEM UNIT IS POWER FROM
ASSOCIATED CONDENSING UNIT. ROVIDE 2#12
& 1#12 EGC IN 3/4" CONDUIT FROM
CONDENSING UNIT. COORDINATE
CONNECTION WITH MECHANICAL
CONTRACTOR PRIOR TO PERFORMING WORK.
6. CIRCUIT NEW LIGHT FIXTURE IN THIS SPACE
TO NEAREST PANEL, PROVIDE 2#12 & 1#12 EGC
IN 3/4"C.
1/8" = 1'-0"
TRAILER 76 - OVERALL FIRST FLOOR PLAN - ELECTRICAL
D16
1/2" = 1'-0"
ENLARGED ELECTRICAL PLAN TR
T78-107 A16 1/2" = 1'-0"
ENLARGED ELECTRICAL PLAN TR
T74-105 A71/2" = 1'-0"
ENLARGED ELECTRICAL PLAN TR
T75-105 A10
1/2" = 1'-0"
ENLARGED ELECTRICAL PLAN TR
T76-105 A13
OFFICE
RESTROOM
STORAGE
OFFICE
OFFICE
101-T73
102-T73
103-T73
104-T73
105-T73
106-T73
107-T73
2D2V
3D 2V
3D2V
3D 2V 2D 2V 2D 2V
3D2V
6D4V
6V 6D
1D-WAP 1D-WAP
D
D
D
D
D
3D 3D 3D
D
3D 3 D
3D
3D
1D-GWAP
1D-WAP
OFFICE AREA
COMM
RESTROOM
OFFICE
OFFICE
OFFICE
OFFICE
101-T75
105-T75
104-T75
103-T75
102-T75 107-T75
106-T75
2D2V
2D2V
2D 2V
2D2V
2D 2V 3D 2V
3D2V
2D2V
1D-WAP
1D-WAP
1D-GWAP
2D2V
OFFICE AREA
RESTROOM
STORAGE
OFFICE
OFFICE
OFFICE
OFFICE
101-T76
104-T76
105-T76
103-T76
102-T76 107-T76
106-T76
3D2V
3D 2V
3D 2V
D
V
2D 2V 2D 2V
D
3D2V
D
V
3D2V
3D 2V
1D 2V
2D2V 2D2V
1D 2V
1D-WAP 1D-WAP1D-GWAP
RESTROOM
3D2V
3D 2V
3D2V
3D 2V
3D2V 3D2V 3D2V
3D 2V
3D2V
3D 2V 3D 2V 3D 2V
1D-WAP
1D-GWAP 1D-WAP
2D2V
RESTROOM
3D2V 3D2V 3D2V 3D2V 3D2V 3D2V 3D2V 3D2V
3D 2V
3D2V
3D 2V3D 2V3D 2V3D 2V
3D2V
3D 2V
1D-WAP 1D-GWAP 1D-WAP
NEW TE
74-105
EXISTING TR
EXISTING TR
EXISTING TR
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
950 N. WASHINGTON ST
SUITE 334
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
BARPDN
EHRM INFRASTRUCTURE UPGRADE
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 73 TO 78 - OVERALL
FIRST FLOOR DEMO PLAN -
TECHNOLOG
T73-TD101
-2
-1
T -T
D
/0
/2
.p d f
1/8" = 1'-0"
TRAILER 73 - OVERALL FIRST FLOOR DEMO PLAN - TECHNOLOGY
A9
1/8" = 1'-0"
TRAILER 74 - OVERALL FIRST FLOOR DEMO PLAN - TECHNOLOGY
D9
1/8" = 1'-0"
TRAILER 75 - OVERALL FIRST FLOOR DEMO PLAN - TECHNOLOGY
G9
1/8" = 1'-0"
TRAILER 76 - OVERALL FIRST FLOOR DEMO PLAN - TECHNOLOGY
A15
1/8" = 1'-0"
TRAILER 77 - OVERALL FIRST FLOOR DEMO PLAN - TECHNOLOGY
D15
1/8" = 1'-0"
TRAILER 78 - OVERALL FIRST FLOOR DEMO PLAN - TECHNOLOGY
G15
N
TRUE
NORTH
N
BUILDING
NORTH
N
TRUE
NORTH
N
BUILDING
NORTH
N
TRUE
NORTH
N
BUILDING
NORTH
N
TRUE
NORTH
N
BUILDING
NORTH
N
TRUE
NORTH
N
BUILDING
NORTH
N
TRUE
NORTH
N
BUILDING
NORTH
NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR SYMBOL LIST.
2. REFER TO INSTALLATION NOTES ON SHEET TN000 FOR MORE INFORMATION ON EXISTING CONDUITS.
3. EXISTING CABLING TO BE REMOVED FROM END TO END AND REPLACED WITH NEW DATA CABLES.
OFFICE
RESTROOM
STORAGE
OFFICE
OFFICE
101-T73
102-T73
103-T73
104-T73
105-T73
106-T73
107-T73
2D
2D
2D
2D 2D 2D
2D
2D 2D
2D 2D
1D-WAP 1D-WAP
D
D
D
D
D
2D 2D 2D
D
2D 2 D
2D
2D
1D-GWAP
1D-WAP
OFFICE AREA
COMM
RESTROOM
OFFICE
OFFICE
OFFICE
OFFICE
101-T75
105-T75
104-T75
103-T75
102-T75 107-T75
106-T75
2D
2D
2D
2D
2D 2D
2D
2D
1D-WAP
1D-WAP
1D-GWAP
2D
OFFICE AREA
RESTROOM
STORAGE
OFFICE
OFFICE
OFFICE
OFFICE
101-T76
104-T76
105-T76
103-T76
102-T76 107-T76
106-T76
2D
2D
2D
D
2D 2D
D
2D
D
2D
2D
2D
2D 2D
2D
1D-WAP 1D-WAP1D-GWAP
RESTROOM
2D
2D
2D
2D
2D 2D 2D
2D
2D
2D 2D 2D
1D-WAP
1D-GWAP 1D-WAP
2D
RESTROOM
2D 2D 2D 2D 2D 2D 2D 2D
2D
2D
2D2D2D2D
2D
2D
1D-WAP 1D-GWAP 1D-WAP
GENERAL NOTES:
1. ALL NEW LOW VOLTAGE CABLING IN THIS BUILDING WILL ROUTE TO TR 105-T74 IN BUILDING 74.
NEW TE
74-105
GENERAL NOTES:
1. ALL NEW LOW VOLTAGE CABLING IN THIS BUILDING WILL ROUTE TO TR 105-T74.
TR 105-T74
T73-TN102
G15
GENERAL NOTES:
1. ALL NEW LOW VOLTAGE CABLING IN THIS BUILDING WILL ROUTE TO TR 105-T75.
TR 105-T75
T73-TN102
B15
GENERAL NOTES:
1. ALL NEW LOW VOLTAGE CABLING IN THIS BUILDING WILL ROUTE TO TR 105-T75 IN BUILDING 75.
T76-TN103
G16
GENERAL NOTES:
1. ALL NEW LOW VOLTAGE CABLING IN THIS BUILDING WILL ROUTE TO TR 107 IN BUILDING 78.
TR 107
GENERAL NOTES:
1. ALL NEW LOW VOLTAGE CABLING IN THIS BUILDING WILL ROUTE TO TR 107.
T76-TN103
B16
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
950 N. WASHINGTON ST
SUITE 334
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
BARPDN
EHRM INFRASTRUCTURE UPGRADE
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 73 TO 78 - OVERALL
FIRST FLOOR PLAN -
TECHNOLOGY
T73-TN101
-2
-1
T -T
N
/0
/2
.p d f
1/8" = 1'-0"
TRAILER 73 - OVERALL FIRST FLOOR PLAN - TECHNOLOGY
A9
1/8" = 1'-0"
TRAILER 74 - OVERALL FIRST FLOOR PLAN - TECHNOLOGY
D9
1/8" = 1'-0"
TRAILER 75 - OVERALL FIRST FLOOR PLAN - TECHNOLOGY
G9
1/8" = 1'-0"
TRAILER 76 - OVERALL FIRST FLOOR PLAN - TECHNOLOGY
A15
1/8" = 1'-0"
TRAILER 77 - OVERALL FIRST FLOOR PLAN - TECHNOLOGY
D15
1/8" = 1'-0"
TRAILER 78 - OVERALL FIRST FLOOR PLAN - TECHNOLOGY
G15
NOTES:
1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY
INSTALLATION NOTES AND SYMBOL LIST.
2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.
3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS
IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.
5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE
OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.
M
R1
CSS
M
R1
CSS
SC-MPP-1
OWNER
PROVIDED
EQUIPMENT
SC-FDC-1
SC-MPP-1
OWNER
PROVIDED
EQUIPMENT
SC-FDC-1
NEW TE
74-105
SC-CAB-1
SC-GND-1
PW-CPW-1
(TYP. OF 2)
PW-CPW-1
AC-SCP-1
SC-TTB
T73-TN102
(TYP.)
NOTES:
1. ALL ELECTRICAL AND MECHANICAL EQUIPMENT INCLUDING BUT NOT LIMITED LIGHTS,
ELECTRICAL PANELS, MECHANICAL UNIT, ETC.ARE SHOWN FOR REFERENCE. REFER TO THE
MECHANICAL AND ELECTRICAL DRAWINGS FOR COMPLETE INFORMATION AND SCOPE
REQUIREMENTS.
2. ALL WIRE BASKET SHALL BE MOUNTED 6" ABOVE THE EQUIPMENT RACK UNLESS OTHERWISE
NOTED.
KEYNOTES:
1. CAMERA TO BE MOUNTED AT 7' 0 FACING DOORWAY. REFER TO TECHNOLOGY EQUIPMENT
SCHEDULE FOR ADDITIONAL INFORMATION ON THE CAMERA TYPE. REFER TO THE CSS
SCHEDULE FOR ADDITIONAL INFORMATION ON SECURITY WITHIN EACH OF THE
TELECOMMUNICATION SPACES.
2. REFER TO H15/0-TN501 FOR DETAILS ON GROUND BAR FOR THIS SPACE. MOUNT GROUND BAR
AT 7'-0" FROM FINISHED FLOOR.
3. THE FIRE RATED TELEPHONE TERMINAL BOARD SHALL COVER ALL THE WALLS INT HE
TELECOMMUNICATIONS ROOM AS SHOWN ABOVE. SHOULD THE WALLS REQUIRE TO BE
PAINTED, THE PAINT SHALL BE "FIRE SAFE" PAINT. IF PAINTED, THE FIRE RATED LABEL ON EACH
BOARD SHALL NOT BE PAINTED. REFER TO THE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
4. REFER TO THE ELECTRICAL DRAWINGS FOR LIGHTING REQUIREMENTS.
G10
74-105
CM-1
74-01
NEW TE
75-105
T73-TN102
B11
PW-CPW-1
AC-SCP-1
SC-TTB
SC-GND-1
(TYP.)
NOTES:
1. ALL ELECTRICAL AND MECHANICAL EQUIPMENT INCLUDING BUT NOT LIMITED
LIGHTS, ELECTRICAL PANELS, MECHANICAL UNIT, ETC.ARE SHOWN FOR
REFERENCE. REFER TO THE MECHANICAL AND ELECTRICAL DRAWINGS FOR
COMPLETE INFORMATION AND SCOPE REQUIREMENTS.
2. ALL WIRE BASKET SHALL BE MOUNTED 6" ABOVE THE EQUIPMENT RACK UNLESS
OTHERWISE NOTED.
KEYNOTES:
1. CAMERA TO BE MOUNTED AT 7' 0 FACING DOORWAY. REFER TO TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION ON THE CAMERA TYPE.
REFER TO THE CSS SCHEDULE FOR ADDITIONAL INFORMATION ON SECURITY WITHIN
EACH OF THE TELECOMMUNICATION SPACES.
2. REFER TO H15/0-TN501 FOR DETAILS ON GROUND BAR FOR THIS SPACE. MOUNT
GROUND BAR AT 7'-0" FROM FINISHED FLOOR.
3. THE FIRE RATED TELEPHONE TERMINAL BOARD SHALL COVER ALL THE WALLS IN
THE TELECOMMUNICATIONS ROOM AS SHOWN ABOVE. SHOULD THE WALLS
REQUIRE TO BE PAINTED, THE PAINT SHALL BE "FIRE SAFE" PAINT. IF PAINTED, THE
FIRE RATED LABEL ON EACH BOARD SHALL NOT BE PAINTED. REFER TO THE
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
4. REFER TO THE ELECTRICAL DRAWINGS FOR LIGHTING REQUIREMENTS.
75-105
CM-1
75-01
SC-CAB-1
(TYP. OF 2)
SPACE RESERVED
FOR ELECTRICAL
RECEPTICLES
OUTGOING HORIZONTAL PATHWAY
INCOMING BACKBONE PATHWAY
SC-GND-1
SC-CAB-1
NOTES:
1. ALL EQUIPMENT SHALL BE LOCATED IN ITS DESIGNATED SPOT AS DEFINED BY THIS LAYOUT UNLESS OTHERWISE NOTED. ALL EQUIPMENT IS SIZED (BY RACK UNITS) ACCORDING TO THE BASIS OF DESIGN MANUFACTURER AND MODEL. THE FINAL LAYOUT AND EQUIPMENT SIZE MAY VARY BASED ON THE FINAL SELECTION OF THE EQUIPMENT. ANY CHANGES TO THE LAYOUT SHOWN ABOVE SHALL BE COORDINATED WITH THE E.O.R AND C.O.R. PRIOR TO INSTALLATION. REFER TO THE GENERAL TECHNOLOGY EQUIPMENT
SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. PROVIDE AND INSTALL A NEW SC-GND-2 TO THE REAR SIDE OF THE RACK.
3. REFER TO E SERIES DRAWINGS FOR ADDITIONAL EQUIPMENT INSTALLED ON THE REAR OF THE RACKS INCLUDING THE UPS, ZONE
PDU AND VERTICAL PDU'S.
SC-FDC-1
SC-BLA-1
SC-BLA-1
SC-HWM-2
SC-MPP-2
SC-HWM-1
SC-MPP-2
SC-HWM-2
NETWORK SWITCH
SC-HWM-2
NETWORK SWITCH
SC-HWM-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-PDU-1
SC-PDU-1
SC-UPS-2
SC-BLA-1
SC-BLA-1
NOTES:
1. ALL EQUIPMENT SHALL BE LOCATED IN ITS DESIGNATED SPOT AS DEFINED BY THIS LAYOUT UNLESS OTHERWISE NOTED. ALL EQUIPMENT IS SIZED (BY RACK UNITS) ACCORDING TO THE BASIS OF DESIGN MANUFACTURER AND MODEL.
THE FINAL LAYOUT AND EQUIPMENT SIZE MAY VARY BASED ON THE FINAL SELECTION OF THE EQUIPMENT. ANY CHANGES TO THE LAYOUT SHOWN ABOVE SHALL BE COORDINATED WITH THE E.O.R AND C.O.R. PRIOR TO INSTALLATION. REFER TO THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
2. PROVIDE AND INSTALL A NEW SC-GND-2 TO THE REAR SIDE OF THE RACK.
3. REFER TO E SERIES DRAWINGS FOR ADDITIONAL EQUIPMENT INSTALLED ON THE REAR OF THE RACKS INCLUDING THE
UPS, ZONE PDU AND VERTICAL PDU'S.
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR
QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR
CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL
INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN.
REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION.
REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO FLOOR PLANS FOR QUANTITY OF CABLES AND JACKS TO BE
INSTALLED AT EACH INFORMATION OUTLET.
KEYNOTES:
1. C# INDICATES DATA FACEPLATE CONFIGURATION. REFER TO THE
INFORMATION OUTLET SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
2. RACK(S) OR CABINET(S) AS DEFINED ON THE TELECOM ROOM LAYOUT.
REFER TO THE TELECOM ROOM REFERENCES MATRIX ON THE COVERPAGE
FOR LOCATION.
3. REFER TO SPECIFICATIONS FOR FIBER PATCH CORD REQUIREMENTS.
4. RJ-45 TO RJ45 CATEGORY 6A UTP PATCH CORDS, REFER TO SPECIFIATIONS.
5. 4-PAIR, CATEGORY 6A, UNSHIELDED TWISTED PAIR CABLE, REFER TO
SPECIFICATIONS.
6. FIBER OPTIC CABLE. REFER TO THE FIBER COPPER DIAGRAM ON XXX FOR
ADDITIONAL INFORMATION.
C#
C#
C#
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR
QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR
CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL
INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN.
REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION.
REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO FLOOR PLANS FOR QUANTITY OF CABLES AND JACKS TO BE
INSTALLED AT EACH INFORMATION OUTLET.
KEYNOTES:
1. C# INDICATES DATA FACEPLATE CONFIGURATION. REFER TO THE
INFORMATION OUTLET SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
2. RACK(S) OR CABINET(S) AS DEFINED ON THE TELECOM ROOM LAYOUT.
REFER TO THE TELECOM ROOM REFERENCES MATRIX ON THE COVERPAGE
FOR LOCATION.
3. REFER TO SPECIFICATIONS FOR FIBER PATCH CORD REQUIREMENTS.
4. RJ-45 TO RJ45 CATEGORY 6A UTP PATCH CORDS, REFER TO SPECIFIATIONS.
5. 4-PAIR, CATEGORY 6A, UNSHIELDED TWISTED PAIR CABLE, REFER TO
SPECIFICATIONS.
6. FIBER OPTIC CABLE. REFER TO THE FIBER COPPER DIAGRAM ON XXX FOR
ADDITIONAL INFORMATION.
C#
C#
C#
SC-FDC-1
SC-BLA-1
SC-BLA-1
SC-HWM-2
SC-MPP-2
SC-HWM-1
SC-MPP-2
SC-HWM-2
SC-HWM-2
SC-HWM-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-PDU-1
SC-PDU-1
SC-UPS-2
NETWORK SWITCH
NETWORK SWITCH
OUTGOING HORIZONTAL PATHWAY INCOMING BACKBONE PATHWAY
SPACE RESERVED
FOR ELECTRICAL
RECEPTICLES
SC-GND-1
SC-CAB-1
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
950 N. WASHINGTON ST
SUITE 334
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
BARPDN
EHRM INFRASTRUCTURE UPGRADE
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 74 & 75 - TECHNOLOGY
ENLARGEMENT
T73-TN102
-2
-1
T -T
N
/0
/2
.p d f
1/2" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
BUILDING T74 TE-105-T74
G15
1/2" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
BUILDING T75 TE-105-T75
B15
1" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
ELEVATION BUILDING T74
TE-105-T75
B11
NO SCALE
HORIZONTAL COPPER DIAGRAM
H5
NO SCALE
HORIZONTAL COPPER DIAGRAM
D5
1" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
ELEVATION BUILDING T74
TE-105-T74
G10
M
R1
CSS
M
R1
CSS
SC-MPP-1
OWNER
PROVIDED
EQUIPMENT
SC-FDC-1
SC-MPP-1
OWNER
PROVIDED
EQUIPMENT
SC-FDC-1
NEW TE
76-105
T76-TN103
G11
PW-CPW-1
(TYP. OF 2)
PW-CPW-1
AC-SCP-1
SC-CAB-1
SC-GND-1
SC-TTB
(TYP.)
NOTES:
1. ALL ELECTRICAL AND MECHANICAL EQUIPMENT INCLUDING BUT NOT LIMITED LIGHTS,
ELECTRICAL PANELS, MECHANICAL UNIT, ETC.ARE SHOWN FOR REFERENCE. REFER TO
THE MECHANICAL AND ELECTRICAL DRAWINGS FOR COMPLETE INFORMATION AND
SCOPE REQUIREMENTS.
2. ALL WIRE BASKET SHALL BE MOUNTED 6" ABOVE THE EQUIPMENT RACK UNLESS
OTHERWISE NOTED.
KEYNOTES:
1. CAMERA TO BE MOUNTED AT 7' 0 FACING DOORWAY. REFER TO TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION ON THE CAMERA TYPE. REFER
TO THE CSS SCHEDULE FOR ADDITIONAL INFORMATION ON SECURITY WITHIN EACH OF
THE TELECOMMUNICATION SPACES.
2. REFER TO H15/0-TN501 FOR DETAILS ON GROUND BAR FOR THIS SPACE. MOUNT
GROUND BAR AT 7'-0" FROM FINISHED FLOOR.
3. THE FIRE RATED TELEPHONE TERMINAL BOARD SHALL COVER ALL THE WALLS INT HE
TELECOMMUNICATIONS ROOM AS SHOWN ABOVE. SHOULD THE WALLS REQUIRE TO BE
PAINTED, THE PAINT SHALL BE "FIRE SAFE" PAINT. IF PAINTED, THE FIRE RATED LABEL
ON EACH BOARD SHALL NOT BE PAINTED. REFER TO THE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
4. REFER TO THE ELECTRICAL DRAWINGS FOR LIGHTING REQUIREMENTS.
(TYP. OF 2)
76-105
CM-1
76-01
NEW TE
78-107
T76-TN103
B11
PW-CPW-1
(TYP. OF 2)
PW-CPW-1
SC-GND-1
SC-CAB-1
AC-SCP-1
SC-TTB
(TYP.)
NOTES:
1. ALL ELECTRICAL AND MECHANICAL EQUIPMENT INCLUDING BUT NOT LIMITED LIGHTS,
ELECTRICAL PANELS, MECHANICAL UNIT, ETC.ARE SHOWN FOR REFERENCE. REFER TO
THE MECHANICAL AND ELECTRICAL DRAWINGS FOR COMPLETE INFORMATION AND
SCOPE REQUIREMENTS.
2. ALL WIRE BASKET SHALL BE MOUNTED 6" ABOVE THE EQUIPMENT RACK UNLESS
OTHERWISE NOTED.
KEYNOTES:
1. CAMERA TO BE MOUNTED AT 7' 0 FACING DOORWAY. REFER TO TECHNOLOGY
EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION ON THE CAMERA TYPE. REFER
TO THE CSS SCHEDULE FOR ADDITIONAL INFORMATION ON SECURITY WITHIN EACH OF
THE TELECOMMUNICATION SPACES.
2. REFER TO H15/0-TN501 FOR DETAILS ON GROUND BAR FOR THIS SPACE. MOUNT
GROUND BAR AT 7'-0" FROM FINISHED FLOOR.
3. THE FIRE RATED TELEPHONE TERMINAL BOARD SHALL COVER ALL THE WALLS INT HE
TELECOMMUNICATIONS ROOM AS SHOWN ABOVE. SHOULD THE WALLS REQUIRE TO BE
PAINTED, THE PAINT SHALL BE "FIRE SAFE" PAINT. IF PAINTED, THE FIRE RATED LABEL
ON EACH BOARD SHALL NOT BE PAINTED. REFER TO THE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
4. REFER TO THE ELECTRICAL DRAWINGS FOR LIGHTING REQUIREMENTS.
78-107
CM-1
78-01
SPACE RESERVED
FOR ELECTRICAL
RECEPTICLES
OUTGOING HORIZONTAL PATHWAY
INCOMING BACKBONE PATHWAY
SC-GND-1
SC-CAB-1
NOTES:
1. ALL EQUIPMENT SHALL BE LOCATED IN ITS DESIGNATED SPOT AS DEFINED BY THIS LAYOUT UNLESS OTHERWISE NOTED.
ALL EQUIPMENT IS SIZED (BY RACK UNITS) ACCORDING TO THE BASIS OF DESIGN MANUFACTURER AND MODEL. THE FINAL LAYOUT AND EQUIPMENT SIZE MAY VARY BASED ON THE FINAL SELECTION OF THE EQUIPMENT. ANY CHANGES TO THE LAYOUT SHOWN ABOVE SHALL BE COORDINATED WITH THE E.O.R AND C.O.R. PRIOR TO INSTALLATION. REFER TO THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. PROVIDE AND INSTALL A NEW SC-GND-2 TO THE REAR SIDE OF THE RACK.
3. REFER TO E SERIES DRAWINGS FOR ADDITIONAL EQUIPMENT INSTALLED ON THE REAR OF THE RACKS INCLUDING THE
UPS, ZONE PDU AND VERTICAL PDU'S.
SC-FDC-1
SC-BLA-1
SC-BLA-1
SC-HWM-2
SC-MPP-2
SC-HWM-1
SC-MPP-2
SC-HWM-2
NETWORK SWITCH
SC-HWM-2
NETWORK SWITCH
SC-HWM-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-PDU-1
SC-PDU-1
SC-UPS-2
SC-BLA-1
SC-BLA-1
SC-GND-1
SC-CAB-1
SPACE RESERVED
FOR ELECTRICAL
RECEPTICLES
OUTGOING HORIZONTAL PATHWAY
INCOMING BACKBONE PATHWAY
NOTES:
1. ALL EQUIPMENT SHALL BE LOCATED IN ITS DESIGNATED SPOT AS DEFINED BY THIS LAYOUT UNLESS OTHERWISE NOTED.
ALL EQUIPMENT IS SIZED (BY RACK UNITS) ACCORDING TO THE BASIS OF DESIGN MANUFACTURER AND MODEL. THE FINAL LAYOUT AND EQUIPMENT SIZE MAY VARY BASED ON THE FINAL SELECTION OF THE EQUIPMENT. ANY CHANGES TO THE LAYOUT SHOWN ABOVE SHALL BE COORDINATED WITH THE E.O.R AND C.O.R. PRIOR TO INSTALLATION. REFER TO THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. PROVIDE AND INSTALL A NEW SC-GND-2 TO THE REAR SIDE OF THE RACK.
3. REFER TO E SERIES DRAWINGS FOR ADDITIONAL EQUIPMENT INSTALLED ON THE REAR OF THE RACKS INCLUDING THE
UPS, ZONE PDU AND VERTICAL PDU'S.
SC-FDC-1
SC-BLA-1
SC-BLA-1
SC-HWM-2
SC-MPP-2
SC-HWM-1
SC-MPP-2
SC-HWM-2
NETWORK SWITCH
SC-HWM-2
NETWORK SWITCH
SC-HWM-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-BLA-1
SC-PDU-1
SC-PDU-1
SC-UPS-2
SC-BLA-1
SC-BLA-1
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR
QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR
CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL
INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN.
REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION.
REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO FLOOR PLANS FOR QUANTITY OF CABLES AND JACKS TO BE
INSTALLED AT EACH INFORMATION OUTLET.
KEYNOTES:
1. C# INDICATES DATA FACEPLATE CONFIGURATION. REFER TO THE
INFORMATION OUTLET SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
2. RACK(S) OR CABINET(S) AS DEFINED ON THE TELECOM ROOM LAYOUT.
REFER TO THE TELECOM ROOM REFERENCES MATRIX ON THE COVERPAGE
FOR LOCATION.
3. REFER TO SPECIFICATIONS FOR FIBER PATCH CORD REQUIREMENTS.
4. RJ-45 TO RJ45 CATEGORY 6A UTP PATCH CORDS, REFER TO SPECIFIATIONS.
5. 4-PAIR, CATEGORY 6A, UNSHIELDED TWISTED PAIR CABLE, REFER TO
SPECIFICATIONS.
6. FIBER OPTIC CABLE. REFER TO THE FIBER COPPER DIAGRAM ON XXX FOR
ADDITIONAL INFORMATION.
C#
C#
C#
NOTES:
1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR
QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR
CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL
INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN.
REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION.
REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. REFER TO FLOOR PLANS FOR QUANTITY OF CABLES AND JACKS TO BE
INSTALLED AT EACH INFORMATION OUTLET.
KEYNOTES:
1. C# INDICATES DATA FACEPLATE CONFIGURATION. REFER TO THE
INFORMATION OUTLET SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
2. RACK(S) OR CABINET(S) AS DEFINED ON THE TELECOM ROOM LAYOUT.
REFER TO THE TELECOM ROOM REFERENCES MATRIX ON THE COVERPAGE
FOR LOCATION.
3. REFER TO SPECIFICATIONS FOR FIBER PATCH CORD REQUIREMENTS.
4. RJ-45 TO RJ45 CATEGORY 6A UTP PATCH CORDS, REFER TO SPECIFIATIONS.
5. 4-PAIR, CATEGORY 6A, UNSHIELDED TWISTED PAIR CABLE, REFER TO
SPECIFICATIONS.
6. FIBER OPTIC CABLE. REFER TO THE FIBER COPPER DIAGRAM ON XXX FOR
ADDITIONAL INFORMATION.
C#
C#
C#
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
950 N. WASHINGTON ST
SUITE 334
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
BARPDN
EHRM INFRASTRUCTURE UPGRADE
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 76 & 78 - TECHNOLOGY
ENLARGEMENT
T76-TN103
-2
-1
T -T
N
/0
/2
.p d f
1/2" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
BUILDING T76 TE-105-T76
G16
1/2" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
BUILDING T78 TE-107-T78
B16
1" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
ELEVATION BUILDING 76
TE-105-T76
G11
1" = 1'-0"
TECHNOLOGY EQUIPMENT ROOM
ELEVATION BUILDING T78
TE-107-T78
B11
NO SCALE
HORIZONTAL COPPER DIAGRAM
H5
NO SCALE
HORIZONTAL COPPER DIAGRAM
C5
OFFICE
COMM
RESTROOM
OFFICE
OFFICE
101-T74
107-T74
106-T74
105-T74
104-T74
103-T74
102-T74
NEW TE CABINET
74-AE401
A14
74-AE401
D14
EXISTING CONDITIONS- GENERAL NOTES
1. EXISTING CONDITION DRAWINGS ARE FOR REFERENCE ONLY. CONTRACTOR SHALL
VERIFY LOCATION OF ALL ITEMS SHOWN ON THIS SHEET PRIOR TO BEGINNING OF WORK.
EXISTING WALL RATING LEGEND
3 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
EXISTING WALL RATING- GENERAL NOTES
1. ALL EXISTING FIRE RATINGS SHOWN HAVE BEEN PROVIDED BY THE VA. CONTRACTOR
SHALL FIELD VERIFY ALL EXISTING PARTITIONS WHERE WORK IS BEING PERFORMED AND
SEAL ALL PENETRATIONS THROUGH ALL FLOOR AND FIRE RATED BARRIERS WITH UL
LISTED ASSEMBLIES TO MAINTAIN FIRE RATED BARRIERS IN PLACE
2. SEE LIFE SAFETY SHEETS FOR DETAILED LIFE SAFETY PLANS.
EXISTING TELECOM
ROOM LOCATION
PLAN LEGEND
NEW TELECOM ROOM/TE
CABINET LOCATION
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
LTCAL
EHRM INFRASTRUCTURE UPGRADES
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 74 - EXISTING CONDITION
PLAN - OVERALL FIRST FLOOR
74-GC101
-2
-1
-G
C
/2
/2
.p d f
1/4" = 1'-0"A11
TRAILER 74 - EXISTING CONDITION - 1ST FLOOR
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
N
PLAN
NORTH
N
OFFICE
COMM
RESTROOM
OFFICE
OFFICE
101-T74
107-T74
106-T74
105-T74
104-T74
103-T74
102-T74
R1
CSS
74-AE401
A14
74-AE401
D14
E X
IS
TI
N G
V .I.
F.
4'
1"
EXISTING V.I.F.
4' - 0" ±
D2
D1
D4
74-105
6 7
NEW TE
74-105
ALIGN
6'
5"
4' - 8"
FLOOR PLAN LEGEND
A3WALL AND DOOR TO REMAIN /
EXISTING CONDITION
WALL AND DOOR TO BE
DEMOLISHED
NEW WORK PARTITION /
NEW WORK DOOR
NEW PARTITION TAG
DEMO PARTITION
NEW PARTITION
NEW PARTITION INFILL
TO MATCH EXISTING
ADJACENT
CONSTRUCTION
PLYWD-01 3/4" AC GRADE FRT
PLYWOOD- SEE
KEYNOTE 8 & FINISH
SCHEDULE
FEC SEMI-RECESSED FIRE
EXTINGUISHER
CABINET- SEE AE-502
FOR DETAILS
ICRA PARTITION- SEE
GC SHEETS FOR ICRA
DETAILS
NOTE: NOT ALL DEMOLITION AND PLAN KEYNOTES APPLY
TO THE FLOOR PLANS ON THIS SHEET
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
LTCAL
EHRM INFRASTRUCTURE UPGRADES
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 74- 1ST FLOOR- ENLARGED
PLANS- DEMO AND NEW WORK
74-AE401
-2
-1
-A
E
/2
/2
.p d f
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
N
PLAN
NORTH
N
1/4" = 1'-0"A11
TRAILER 74 - OVERALL 1ST FLOOR
1/2" = 1'-0"A14
74 TRAILER - 1ST FLOOR- DEMO WORK PLAN
1/2" = 1'-0"D14
74 TRAILER - 1ST FLOOR- NEW WORK PLAN
KEYNOTES - DEMOLITION
D1 REMOVE EXISTING DOOR, FRAME, AND HARDWARE IN THEIR ENTIRETY.
D2 REMOVE EXISTING FLOOR FINISH AND BASE WHERE REQUIRED. PREP SUBSURFACE, AS
REQUIRED, TO RECEIVE NEW FLOOR FINISH- SEE FINISH SCHEDULE
D3 REMOVE PORTION OF EXISTING WALL, AS REQUIRED, AND PREP OPENING TO RECEIVE NEW
DOOR AND DOOR FRAME- SEE DOOR SCHEDULE
D4 REMOVE EXISTING WALL IN ITS ENTIRETY TO EXTENTS SHOWN ON FLOOR PLAN.
D5 REMOVE ALL EXISTING PLUMBING FIXTURES IN THEIR ENTIRETY. CAP ALL PIPES AND VALVES
PRIOR TO START OF NEW WORK- SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
PATCH/REPAIR WALL AND PREP, AS REQUIRED, TO RECEIVE NEW FINISH
D6 REMOVE PORTION OF EXISTING WALL TO EXTENTS SHOWN ON FLOOR PLAN.
D7 EXISTING COLUMN SHALL REMAIN. CONTRACTOR SHALL COVER AND PROTECT EXISTING
COLUMNS DURING DEMO AND NEW WORK PHASES.
D8 REMOVE EXISTING CASEWORK AND COUNTERTOPS IN THEIR ENTIRETY. REMOVE ALL EXISTING
APPLIANCES, AS REQUIRED, AND RETURN TO VA.
D9 REMOVE EXISTING DOOR, FRAME, AND HARDWARE IN THEIR ENTIRETY. PREP EXISTING
OPENING TO RECEIVE NEW DOOR AND DOOR FRAME- SEE DOOR SCHEDULE FOR NEW DOOR
SIZE.
D10 REMOVE EXISTING WINDOW IN ITS ENTIRETY. PREP OPENING TO RECEIVE NEW WALL INFILL-
SEE NEW WORK FLOOR PLAN
D11 REMOVE EXISTING SLIDING DOOR STOREFRONT SYSTEM IN ITS ENTIRETY. PREP EXISTING
OPENING TO RECEIVE NEW DOORS AND NEW WALL INFILL- SEE NEW WORK FLOOR PLAN
D12 REMOVE EXISTING CONCRETE CURB IN ITS ENTIRETY. PREP SUBFLOOR TO RECEIVE NEW
FLOOR FINISH- SEE NEW WORK FLOOR PLAN
D13 REMOVE EXISTING FENCE, FENCE STRUCTURE, GATE AND HARDWARE IN THEIR ENTIRETY.
KEYNOTES - PLAN
1 PROVIDE AND INSTALL NEW DOOR, DOOR FRAME, AND HARDWARE- SEE DOOR SCHEDULE
2 NEW PARTITION- SEE WALL TYPE. PREP NEW PARTITION, AS REQUIRED, TO SEE NEW
FINISHES- SEE FINISH SCHEDULE
3 PROVIDE AND INSTALL NEW FLOORING AND WALL BASE, AS REQUIRED, FLOORING AND WALL
BASE SHALL MATCH EXISTING ADJACENT FLOORING AND WALL BASE. PREP WALL TO RECEIVE
NEW FINISHES ON EXISTING SIDE OF WALL. NEW FINISHES SHALL MATCH EXISTING.
4 PROVIDE AND INSTALL STAINLESS STEEL SECURITY MESH AT ALL WINDOWS. APPLY BLACK
OUT FILM (BF-01) TO WINDOW GLAZING PRIOR TO INSTALLATION OF SECURITY MESH. SEE
DETAIL
5 RE-FRAME OPENING TO RECEIVE NEW WALL INFILL. WALL INFILL SHALL MATCH EXISTING
WALL CONSTRUCTION. NEW WALL INFILL SHALL BE FLUSH WITH ADJACENT WALL
CONSTRUCTION, TAPE, MUD, AND FLOAT, AS REQUIRED, AND PREP TO RECEIVE NEW PAINT.
6 PROVIDE & INSTALL NEW 3/4" AC GRADE FRT PLYWOOD ON WALLS TO EXTENTS SHOWN ON
PLANS. BOTTOM EDGE OF PLYWOOD SHALL BE INSTALLED 12" AFF- SEE FINISH SCHEDULE
7 PROVIDE & INSTALL NEW FLOOR FINISH AND WALL BASE- SEE FINISH SCHEDULE. REFER TO
ELECTRICAL DRAWINGS FOR GROUND OF STATIC DISSIPATING FLOOR.
8 INFILL EXISTING OPENING IN FLOOR ASSEMBLY WHERE EXISTING CHASE WAS REMOVED. NEW
CONCRETE INFILL SHALL MATCH THE EXISTING ADJACENT FLOOR/ROOF ASSEMBLY
CONSTRUCTION TO MAINTAIN THE EXISTING RATING OF THE FIRE RATED ASSEMBLY. TOP OF
INFILL FINISH SHALL BE ALIGNED WITH AND BE FLUSH WITH ADJACENT TOP OF SLAB
ELEVATION. REFER TO STRUCTURAL DRAWINGS FOR ADDITONAL INFORMATION. PREP NEW
CONCRETE INFILL, AS REQUIRED, TO RECEIVE NEW FLOOR FINISH- SEE FINISH SCHEDULE
9 FRAME OPENING IN EXISTING WALL TO PROVIDE ACCESS TO NEW DOOR AND NEW TR ROOM
10 PROVIDE AND INSTALL NEW BLACK OUT FILM ON INTERIOR SIDE OF EXISTING WINDOW. SEE
BF-01 IN FINISH SCHEDULE.
D#
6" PLUMB WALL
OFFICE
OFFICE
COMM
RESTROOM
OFFICE
OFFICE
101-T74
107-T74
106-T74
105-T74
104-T74
103-T74
102-T74
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED NOTED OR
OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING
TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. CONTRACTOR SHALL REFERENCE ICRA, HAZARDOUS MATERIALS, DEMOLITION AND NEW
WORK SHEETS FOR ALL DISCIPLINES IN COORDINATING AND CONFIRMING DEMOLITION
SCOPE, REQUIREMENTS, PROCEDURES, AND WASTE REMOVAL.
2. CONTRACTOR SHALL COMPLY WITH APPLICABLE REGULATIONS, AS DEFINED ELSEWHERE
IN THE SPECIFICATIONS AND DRAWINGS, TO INCLUDE OSHA SILICA DUST CONTROL
REGULATIONS 29 CFR 1926.1153, 29 CFR 1910.134.
3. GENERAL CONTRACTOR SHALL FILL OUT ATTACHMENT C OF 138-022HV LOCATED IN SPEC
SECTION 01 35 26.19 FOR ALL DEMOLISHED EQUIPMENT INSTALLED IN THIS SCOPE OF
WORK.
FIRE PROTECTION DEVICES, EXIT SIGNS, AND TELECOMMUNICATION EQUIPMENT WITHIN THE
SCOPE OF WORK IS TO BE DEMOLISHED.
GENERAL DEMOLITION RCP NOTES
DEMO PLASTER /
GYPSUM BOARD CEILING
RCP LEGEND
NOTE: SPOT ELEVATION SUFFIX "C.H." INDICATES FLAT CEILING HEIGHT ABOVE FINISH FLOOR.
SUFFIX "L.P." AND "H.P." INDICATE LOW POINT AND HIGH POINT OF SLOPED CEILING. WHERE ADJACENT, TRANSITION BETWEEN FLAT AND SLOPED CEILINGS SHALL UTILIZE APPROVED PRE-
FINISHED ALUMINUM TRANSITION STRIP. REFER TO SPECIFICATIONS.
DEMO 2X4 ACT CEILING
TILE & GRID
DEMO 2X2 ACT CEILING
TILE & GRID
DEMO 2X4 LIGHT
FIXTURE
DEMO SUPPLY
DIFFUSER
DEMO RETURN
DIFFUSER
NEW 2X2 ACT CEILING
TILE & GRID
NEW 2X4 LIGHT
FIXTURE - SEE ELEC
NEW SUPPLY
DIFFUSER - SEE MECH
NEW RETURN
DIFFUSER - SEE MECH
NEW 6" X 4'-0 LIGHT
FIXTURE - SEE ELEC
NEW 6" DIA. DOWN LIGHT
FIXTURE - SEE ELEC
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED NOTED OR
OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING
TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR SIMILAR CONDITIONS.
1. ALL NEW TRS SHALL BE OPEN TO DECK ABOVE.
2. REFER TO ELECTRICAL DRAWINGS FOR LIGHT PATTERN AND EXIT LIGHT LOCATIONS.
NOTIFY ARCHITECT OF DISCREPANCIES PRIOR TO SHOP DRAWINGS.
3. ALL WALLS SHOWN SHALL EXTEND TO THE STRUCTURAL DECK (SEE WALL TYPES).
CORRIDOR CHASE WALLS AND LOCKER WING WALLS SHALL EXTEND 4" MINIMUM ABOVE
THE CEILING.
4. WHERE CEILING TILES ARE SCHEDULED, REFER TO MECHANICAL, PLUMBING AND
ELECTRICAL DRAWINGS FOR ITEMS NOT SHOWN ON CEILING PLAN. GRILLES, SPEAKERS,
SPRINKLERS, HEAT & SMOKE DETECTORS, SHALL BE CENTERED IN TILES (WHERE
SCHEDULED) UNLESS NOTED OTHERWISE.
5. IN AREAS OF EXPOSED STRUCTURE, PAINT EXPOSED STRUCTURE, UNDERSIDE OF DECK,
SPRINKLER PIPING, CONDUIT AND ALL MISCELLANEOUS OVERHEAD ITEMS. COLORS SHALL
BE SELECTED BY ARCHITECT.
GENERAL RCP NOTES
74-AE701
E11
74-AE701
E8
D33
D30
D41 D43
NEW TE
74-105
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
LTCAL
EHRM INFRASTRUCTURE UPGRADES
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 74- 1ST FLOOR- REFLECTED
CEILING PLANS- DEMO AND NEW
WORK
74-AE701
-2
-1
-A
E
/2
/2
.p d f
KEYNOTES - DEMOLITION RCP
D30 REMOVE EXISTING CEILING TILE, GRID, SUPPORTS, AND FRAMING IN THEIR ENTIRETY.
D31 REMOVE EXISTING LIGHT FIXTURES, DIFFUSERS,GRILLES AND ALL CEILING MOUNTED
ACCESORRIES LOCATED WITHIN EXISTING CEILING BEING DEMOLISHED.
D32 REMOVE EXISTING GYPSUM BOARD CEILING AND SUPPORTS IN THEIR ENTIRETY TO EXTENTS
SHOWN ON REFLECTED CEILING PLAN.
D33 EXISTING CEILING SHALL REMAIN. CONTRACTOR SHALL REWORK EXISTING CEILING GRID, TILE, LIGHTING, AND AIR REGISTERS, AS REQUIRED.
D36 EXISTING PLASTER CEILING, AIR TERMINALS, LIGHT FIXTURES, AND CEILING FAN SHALL
REMAIN
D37 EXISTING PLASTER CEILING SHALL REMAIN. CONTRACTOR SHALL REMOVE EXISTING AIR
TERMINALS, LIGHTS FIXTURES, AND CEILING FAN IN THEIR ENTIRETY FROM EXISTING PLASTER
CEILING.
D38 EXISTING CEILING OPEN TO STRUCTURE ABOVE. CONTRACTOR SHALL REMOVE EXISTING
LIGHT FIXTURES AND AIR TERMINALS, AS REQUIRED.
D39 REMOVE EXISTING SOFFIT AND SUPPORTS, IN THEIR ENTIRETY, TO EXTENTS SHOWN ON
REFLECTED CEILING PLAN
D40 REMOVE EXISTING MINISPLIT IN ITS ENTIRETY- SEE MECHANICAL DRAWINGS
D41 EXISTING CEILING AND SUPPORTS SHALL REMAIN
D42 REMOVE EXISTING CEILING MOUNTED CURTAIN TRACK IN ITS ENTIRETY.
D43 EXISTING LIGHT FIXTURE SHALL REMAIN. CONTRACTOR SHALL PROTECT EXISTING ITEMS TO
REMAIN, AS REQUIRED, THROUGHOUT DEMOLITION AND NEW CONSTRUCTION WORK
KEYNOTES - RCP
1 NEW TR SHALL BE EXPOSED TO STRUCTURE ABOVE. ALL EXPOSED STRUCTURE AND DECK
SHALL BE SPRAYED WITH 2HR FIRE RESISTIVE MATERIAL PER UL N759
2 NEW SUSPENDED LIGHTING FIXTURE- SEE ELECTRICAL. NEW LIGHT FIXTURE SHALL BE HUNG
FROM UNDERSIDE OF EXISTING DECK ABOVE
3 NEW LAY IN CEILING TILE AND GRID SHALL MATCH EXISTING ADJACENT CEILING TILE AND GRID IN SIZE, TYPE, AND COLOR. PROVIDE AND INSTALL NEW LIGHT FIXTURES CENTERED IN
NEW CEILING TILE.
4 EXISTING CEILING, SOFFIT, MOLDING, TRIM AND CEILING FIXTURES SHALL REMAIN.
CONTRACTOR SHALL REWORK EXISTING CEILING AND SOFFIT TO REMAIN, AS REQUIRED.
5 RELOCATED LIGHT FIXTURE IN EXISTING CEILING GRID
6 RELOCATED AIR TERMINAL. CONTRACTOR SHALL TEST AND BALANCE AS REQUIRED- SEE
MECHANICAL FOR DETAILS
7 EXISTING LAY-IN CEILING TILE, CEILING GRID, LIGHT FIXTURES AND ALL CEILING MOUNTED
EQUIPMENT SHALL REMAIN. CONTRACTOR SHALL REWORK EXISTING CEILING, AS REQUIRED,
FOR DEMOLITION AND NEW WORK
8 PROVIDE AND INSTALL NEW LAY IN CEILING TILE AND GRID. NEW TILE AND GRID SHALL MATCH
EXISTING ADJACENT CEILING TILE AND GRID IN SIZE, TYPE, AND COLOR.
9 PROVIDE AND INSTALL NEW DRYWALL CEILING AND SUPPORTS, AS REQUIRED, TO EXTEND
EXISTING DRYWALL CEILING TO NEW WALL. NEW DRYWALL CEILING SHALL MATCH EXISTING
CEILING HEIGHT ABOVE FINISH FLOOR. TAPE, MUD, AND FLOAT, AS REQUIRED, TO PROVIDE
SMOOTH TRANSITION BETWEEN EXISTING AND NEW. PREP TO RECEIVE NEW PAINT.
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
N
PLAN
NORTH
N 1/4" = 1'-0"A11
TRAILER 74- 1ST FLOOR REFLECTED CEILING PLAN
1/2" = 1'-0"E11
TRAILER 74- 1ST FLOOR- DEMO WORK RCP
1/2" = 1'-0"E8
TRAILER 74- 1ST FLOOR- NEW WORK RCP
TRUE
NORTH
COMM
RESTROOM
OFFICE
OFFICE
OFFICE
OFFICE
101-T75
105-T75
104-T75
103-T75
102-T75 107-T75
106-T75
NEW TE CABINET
75-AE401
A14
75-AE401
D14
EXISTING CONDITIONS- GENERAL NOTES
1. EXISTING CONDITION DRAWINGS ARE FOR REFERENCE ONLY. CONTRACTOR SHALL
VERIFY LOCATION OF ALL ITEMS SHOWN ON THIS SHEET PRIOR TO BEGINNING OF WORK.
EXISTING WALL RATING LEGEND
3 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
EXISTING WALL RATING- GENERAL NOTES
1. ALL EXISTING FIRE RATINGS SHOWN HAVE BEEN PROVIDED BY THE VA. CONTRACTOR
SHALL FIELD VERIFY ALL EXISTING PARTITIONS WHERE WORK IS BEING PERFORMED AND
SEAL ALL PENETRATIONS THROUGH ALL FLOOR AND FIRE RATED BARRIERS WITH UL
LISTED ASSEMBLIES TO MAINTAIN FIRE RATED BARRIERS IN PLACE
2. SEE LIFE SAFETY SHEETS FOR DETAILED LIFE SAFETY PLANS.
EXISTING TELECOM
ROOM LOCATION
PLAN LEGEND
NEW TELECOM ROOM/TE
CABINET LOCATION
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
LTCAL
EHRM INFRASTRUCTURE UPGRADES
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 75 - EXISTING CONDITION -
OVERALL FIRST FLOOR PLAN
75-GC101
-2
-1
-G
C
/2
/2
.p d f
1/4" = 1'-0"A11
TRAILER 75 - EXISTING CONDITION - 1ST FLOOR N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
N
PLAN
NORTH
N
RESTROOM
OFFICE
OFFICE
OFFICE
OFFICE
101-T75
105-T75
104-T75
103-T75
102-T75 107-T75
106-T75
R1
CSS
75-AE401
A14
75-AE401
D14 D2
D1 D4
E X
IS
TI
N G
V .I.
F.
4'
1"
EXISTING V.I.F.
4' - 0" ±
6'
5"
NEW TE
75-105
6 7
75-105
ALIGN
5' - 3"
FLOOR PLAN LEGEND
A3WALL AND DOOR TO REMAIN /
EXISTING CONDITION
WALL AND DOOR TO BE
DEMOLISHED
NEW WORK PARTITION /
NEW WORK DOOR
NEW PARTITION TAG
DEMO PARTITION
NEW PARTITION
NEW PARTITION INFILL
TO MATCH EXISTING
ADJACENT
CONSTRUCTION
PLYWD-01 3/4" AC GRADE FRT
PLYWOOD- SEE
KEYNOTE 8 & FINISH
SCHEDULE
FEC SEMI-RECESSED FIRE
EXTINGUISHER
CABINET- SEE AE-502
FOR DETAILS
ICRA PARTITION- SEE
GC SHEETS FOR ICRA
DETAILS
NOTE: NOT ALL DEMOLITION AND PLAN KEYNOTES APPLY
TO THE FLOOR PLANS ON THIS SHEET
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
CONSULTANT:
COMPASS
8734 GALLOWAY TRAIL
NOVELTY, OH. 44072
619-925-1647
ARCHITECT:
CB DESIGN GROUP
421 KING ST
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.
Tampa, FL. 33612
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
SCOTT PRZYBYSZ
15 SUNNEN DR. SUITE 104
ST. LOUIS, MO 63143
314-951-2535
CONSULTANT:
MARK DYCK
148 S. QUEEN ST. SUITE 201
MARTINSBURG, WV. 25401
304-266-3115
CONSULTANT:
CLARE KRAMER
2815 DIRECTORS ROW
SUITE 500
ORLANDO, FL. 32809
407-917-2430
04/04/2025
673-20-107
LTCAL
EHRM INFRASTRUCTURE UPGRADES
TAMPA, FL.
ISSUED FOR CONSTRUCTION
TRAILER 75- 1ST FLOOR- ENLARGED
PLANS- DEMO AND NEW WORK
75-AE401
-2
-1
-A
E
/2
/2
.p d f
N
TRUE NORTH
SITE KEY PLAN
SCALE: NOT TO SCALE
N
PLAN
NORTH
N
TRUE
NORTH
1/4" = 1'-0"A11
TRAILER 75 - OVERALL 1ST FLOOR
1/2" = 1'-0"A14
75 TRAILER - 1ST FLOOR- DEMO WORK PLAN
1/2" = 1'-0"D14
75 TRAILER - 1ST FLOOR- NEW WORK PLAN
KEYNOTES - DEMOLITION
D1 REMOVE EXISTING DOOR, FRAME, AND HARDWARE IN THEIR ENTIRETY.
D2 REMOVE EXISTING FLOOR FINISH AND BASE WHERE REQUIRED. PREP SUBSURFACE, AS
REQUIRED, TO RECEIVE NEW FLOOR FINISH- SEE FINISH SCHEDULE
D3 REMOVE PORTION OF EXISTING WALL, AS REQUIRED, AND PREP…