This file is a comprehensive technology infrastructure design document containing basement through seventh floor floor plans for Building 01 at James A. Haley Veterans Hospital in Tampa, Florida, as part of Project 673-20-107 EHRM Infrastructure Upgrades. The document, dated April 4, 2025 (revised April 14, 2026), includes detailed architectural and technology layout drawings prepared by CB Design Group, with consultants Compass, Scott Przybysz, Mark Dyck, and Clare Kramer. The plans specify low voltage cabling infrastructure, including Cat 6A information outlets, conduit routing, cable tray pathways, and telecommunications room (TR) locations across multiple floors. Key infrastructure elements include new J-hook routes for cabling, reference to CAT 6A outlets with provisions for future installations, field verification requirements for conduit riser routes, and coordination of cabling work during occupied hospital operations with staff and patients present. The document references a technology coversheet (TN000), equipment schedule (TN700), and multiple area-specific plans with symbols for wireless access points (1D-WAP), cameras (1D-CAM), generic wall access points (1D-GWAP), and standard two-port outlets (2D).

The solicitation RFP 36C77625R0092 for this project, managed by the Department of Veterans Affairs Technology Acquisition Center Austin, has undergone multiple amendments (0001 through 0009 as of April 15, 2026) addressing site visit sign-in procedures, due date extensions, responses to requests for information (RFIs), and provision/clause additions. The project involves comprehensive construction and technology infrastructure upgrades to the hospital facility, with the contractor responsible for providing new low voltage cabling infrastructure, coordinating installations with building occupancy, and utilizing existing cable tray capacity where accessible. The effort requires detailed attention to technology specifications across basement and seven above-grade floors, with specific routing requirements to designated telecommunications rooms on each floor level.

View the file

Other files

File Type Posted
673-107.30.Tech.pdf PDF
673-107.38.Tech.pdf PDF
673-107.39.Tech.pdf PDF
673-107.52.Tech.pdf PDF
673-107.54.Tech.pdf PDF
4-15 RFI TRACKING SHEET - SOLICITATION 36C77625R0092 - Final.pdf PDF
Tampa EHRM Addendum 2 Narrative.pdf PDF
673-107.32.Tech.pdf PDF
673-107.53.Tech.pdf PDF
673-107. 0-TN002.pdf PDF
673-107.36.Tech.pdf PDF
673-107.41.Tech.pdf PDF
673-107.68.Tech.pdf PDF
Roof - As Built.pdf PDF
4-8 RFI TRACKING SHEET - SOLICITATION 36C77625R0092 - Amend 7.pdf PDF
4-7 RFI TRACKING SHEET - SOLICITATION 36C77625R0092 - Amend 6.pdf PDF
Question 161 - Lay down area.pdf PDF
Amendment 6 - 36C77625R0092 0006.pdf PDF
Amendment 5 - 36C77625R0092 0005.pdf PDF
Revised 2.8 and 2.9 Tampa.pdf PDF
3-30 RFI TRACKING SHEET - SOLICITATION 36C77625R0092 Amend 4.pdf PDF
01 32 16.15- Project Schedules-Small Projects.pdf PDF
Amendment 4 - 36C77625R0092 0004.pdf PDF
03-27-2026 Addendum 1 Combined Drawings.pdf PDF
3-27 RFI TRACKING SHEET - SOLICITATION 36C77625R0092 Amend 3.pdf PDF
Amendment 3 - 36C77625R0092 0003.pdf PDF
Amendment 2 - 36C77625R0092 0002.pdf PDF
Amendment 1 - 36C77625R0092 0001.pdf PDF
Site Visit Attendance - Tampa EHRM.pdf PDF
Attachment 4 - Drawings Vol 1 Part2.pdf PDF
Attachment 8 - Drawings Vol 2 Part1.pdf PDF
Attachment 13 - Brand Name Justification - Tampa_Redacted.pdf PDF
Attachment 17 - PPQ.docx DOCX document
Attachment 18 - Project Information Sheet for Contractors.docx DOCX document
Attachment 1 - Spec Vol 1 - R1.pdf PDF
Attachment 6 - Drawings Vol 1 Part4.pdf PDF
Attachment 9 - Drawings Vol 2 Part2.pdf PDF
Attachment 11 - Drawings Vol 2 Part4.pdf PDF
Attachment 12 - Drawings Vol 3.pdf PDF
Attachment 19 - Division Cost Breakdown.xlsx XLSX spreadsheet
RFP - 36C77625R0092.pdf PDF
Attachment 2 - Spec Vol 2 - R1.pdf PDF
Attachment 15 - Limitations on Subcontracting Clause.docx DOCX document
Attachment 16 - Site Visit Instructions.pdf PDF
Attachment 20 - RFI TRACKING SHEET - SOLICITATION 36C77625R0092 - Project 673-20-107.xlsx XLSX spreadsheet
Attachment 3 - Drawings Vol 1 Part1.pdf PDF
Attachment 5 - Drawings Vol 1 Part3.pdf PDF
Attachment 7 - Drawings Vol 1 Part5.pdf PDF
Attachment 10 - Drawings Vol 2 Part3.pdf PDF
Attachment 14 - Construction Wage Rates - Hillsborough 1-2-2025.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

279 SF

5,186 SF

238 SF

411 SF

1,540 SF

319 SF 383 SF

727 SF

1,617 SF

676 SF

201 SF

261 SF

446 SF

2,565 SF

284 SF

MISC ELECTRICAL

STORAGE

STORAGE

PAINT STORAGE

AND MIX

PLUMBING

STORAGE

ELECTRICAL

PLANS

STORAGE MECH AREA

A/C REFRIGERANT

STORAGE ELECTRONIC

STORAGE

ELECTRONIC

STORAGE

BIOMED

BULK MOTOR

STORAGE PROJECT

WORK ROOM

MECHANICAL

LOCKSHOP

CB-3b

CB-3a

CB-1

CB-1c

CB-1h

CB-1b CB-2

CB-1a CB-1e

CB-1e

CB-1g

CB-1p

CB-4b

CB-4

CB-10

UP

UP

UP

D

2D

2D

2D

2D

D

2D

2D2D

D

2D

2D

2D2D2D

2D

D

2D 2D

1D-WAP

1D-CAM

1D-GWAP

1D-CAM1D-WAP

1D-WAP

1D-GWAP

2D

1D-WAP

1D-WAP

1D-WAP

ALL

N

E W

L O W

V O

LT

A G E

C A

BLI

N G

IN

T H

IS

A R

EA

W

IL

L

R O U

TE T

O T

R D

B-5 A

ALL

N

E W

L O W

V O

LT

A G E

C A

BLI

N G

IN

T H

IS

A R

EA

W

IL

L

R O U

TE T

O T

R C

B-6 D

1/01-TN100B

1/01-TN100D

1/01-TN100E

/0

-T

N D

1/01-TN100C

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA A - TECHNOLOGY

01-TN100A

-2

-1

-T

N A

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA A - TECHNOLOGY

A13

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

640 SF

3,740 SF

279 SF

MECHANICAL

MISC ELECTRICAL

STORAGE

BD-09

DB-xx

CB-3b

B

A

B

A 1S

Y

U P

DN

PLENUM

TRENCH

TRENCH

PIT

1D-WAP

1D-CAM

1D-CAM

W

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A.

1/01-TN100D

1/01-TN100E

1/01-TN100E

1/01-TN100F 1/01-TN100C 1/01-TN100C

A13/01-TN100A A13/01-TN100A

1/01-TN100C

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA B - TECHNOLOGY

01-TN100B

-2

-1

-T

N B

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA B - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

10128

E L E V

.6

168 SF

299 SF291 SF

9,750 SF

2,317 SF

119 SF

116 SF

303 SF

470 SF

169 SF

655 SF

724 SF

551 SF

49,581 SF

109 SF

37 SF

STAIR #22

ELECTRICALCOMMUNICATIONS

MECHANICAL

MECHANICAL

OFFICE

CONFERENCE

ROOM

FILE ROOM

SAFE TV

STORAGE

STORAGE

STORAGE

RECORDS STORAGE

MECHANICAL

SB-22-1

BD-12BD-11

BD-10

DB-xx

DB-36b

DB-7a DB-7c

DB-7

DB-6

DB-5

DB-3

DB-8

AB-1

Space

Space

A S

-1

E T-1

HX-1

HX-2

P H

W P

-1 S

H W

P -1

A C

ID

TA

N K

A H

U -203

H E

A

TIN

G C

O

IL

C O

O

LIN

G C

O

IL

B O

O S

TE

R

C O

O

LIN

G C

O

IL

FA

N

S E

C

TIO

N

A H

U -204

C

LG

C O

IL

H

TG

C O

IL

L dP

H

L dP

H

H dP

L

L dP

H

B

A 1S

B

A 1S

B

A 1S

UP

UP

DN

UP

STAIR NO.

OPEN

RISER

U P

RETAINING

WALL

H

W

1D-WAP

1D-WAP

1D-CAM

1D-GWAP

1D-WAP

1D-WAP

1D-WAP

2D

1D-CAM

NEW TR

DB-5A

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A.

01-TN303

G16

1/01-TN100E

1/01-TN100F

/0

-T

N F

1/01-TN100B 1/01-TN100B

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA C - TECHNOLOGY

01-TN100C

-2

-1

-T

N C

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA C - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

5,186 SF

1,119 SF

1,089 SF

121 SF

58 SF

467 SF

412 SF

596 SF

79 SF

851 SF

1,062 SF

882 SF

238 SF

1,540 SF

166 SF

398 SF

196 SF

57 SF110 SF

2,336 SF

293 SF

120 SF120 SF

1,425 SF

183 SF

220 SF213 SF

156 SF

401 SF

427 SF

46 SF 46 SF

284 SF

114 SF

97 SF

1,176 SF

MISC ELECTRICAL

STORAGE

STORAGE

CARPENTRY

CARPENTRY

SHOP STORAGE

STAIR #20

TOILET

SIGN SHOP

PAINT STORAGE

AND MIX

ELECTRICAL

PLANS

FAN BELT

STORAGE

EMS

MISC A/C

ICE MACHINE

REPAIR

SUPERVISOR 138M1SUPERVISOR 138M2

CARPENTRY SHOP

A/C STORAGE

LIGHT BULB

STORAGE

UPS

---- OFFICE

LOCKSHOP

CORRIDOR

CB-3b

CB-3a

CB-3c

CB-3d

SB-20-1

CB-6b

CB-6c

CB-6d

CB-6a

CB-6e

CB-6f

CB-6g

CB-6h

CB-1

CB-1h

CB-5a

BB-4

BB-2b

BB-5BB-2h

BB-2j

BB-2d

BB-8BB-9

BB-2

BB-2l

BB-2iBB-3

BB-2k

BB-1d

BB-2e

BB-7 BB-6

CB-10

BB-20

BB-21

CB-??

E-11

UP

UP

UP

T

TT

T

T

T

2D 2D

D

W

D

D

D

2D

1D-WAP

1D-WAP

1D-WAP

1D-WAP

2D

D

1D-WAP

1D-WAP

1D-CAM

1D-CAM

D

2D

D

W D

2D

D

D2

D2 D

2D

1D-WAP

D

1D-GWAP

2D

D

W D

D

1D-WAP

1D-WAP

1D-CAM

1D-WAP

1D-CAM

1D-WAP

1D-WAP

1D-GWAP

D

NONE

CB-6D

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR CB-6D.

01-TN301

G16

1/01-TN100E

A13/01-TN100A

A /0

-T

N A

1/01-TN100C

1/01-TN100E1/01-TN100H

1/01-TN100G

/0

-T

N G

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA D - TECHNOLOGY

01-TN100D

-2

-1

-T

N D

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA D - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

1,119 SF

378 SF

166 SF

49,581 SF

MISC ELECTRICAL

STORAGECARPENTRY

SHOP STORAGE

CONSTRUCTION

CREW

FAN BELT

STORAGE

MECHANICAL

CB-3b CB-3c

CB-5c

CB-5a

AB-1

S T A

IR

UP

UP

T

D

ALL N

EW

L

OW

V

OLTAGE

CABLIN

G IN

T

HIS

A

REA W

ILL

ROUTE T

O T

R C B-6

ALL N

EW

LOW

V

OLTAGE

CABLIN

G IN

T

HIS

A

REA W

ILL

ROUTE T

O T

R A B-5

A.

1/01-TN100D

1/01-TN100F 1/01-TN100C

A13/01-TN100A

1/01-TN100B

1/01-TN100C

1/01-TN100H

1/01-TN100G

1/01-TN100F

1/01-TN100H

1/01-TN100J

1/01-TN100D

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA E - TECHNOLOGY

01-TN100E

-2

-1

-T

N E

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA E - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

724 SF

956 SF

1,003 SF

49,581 SF

288 SF

STORAGE

RECORDS STORAGE

RECORDS STORAGE

MECHANICAL

STORAGE

DB-3

DB-2

AB-5

AB-1

DB-9

UP

UP

STAIR

#2

UP

STAIR NO.

OPEN

RISER

1D

2D W

1D-WAP

1D-CAM

W 2D

1D-WAP

1D-CAM

NEW TR

AB-5A

ALL N

EW

L

OW

V

OLTAGE

CABLIN

G IN

T

HIS

A

REA W

ILL

ROUTE T

O T

R A B-5

A.

ALL

NEW

L O

W V

O

LTAG

E

CABLIN

G

IN

T

HIS

A

REA W

IL

L

RO

UTE T

O T

R D B-5

A.

01-TN302

G16

1/01-TN100E

1/01-TN100C

1/01-TN100B1/01-TN100H

1/01-TN100J

/0

-T

N C1

/0 -T

N J

1/01-TN100E

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA F - TECHNOLOGY

01-TN100F

-2

-1

-T

N F

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA F - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

401 SF

145 SF

145 SF

1,105 SF

159 SF

649 SF61 SF

WORK LEADER

ELECTRICAL &

STRUCTURAL

WORK LEADER

A/C & PLUMBING

WORK BENCHES

AND TOOL CARTS

WELDING

BEDS/MECH REPAIREMERGENCY

SUPPLIES

BB-1d

BB-10

BB-11

BB-1d

BB-1g

BB-1BB-1p

E-11

UP

T T

T

T

RAMP

UP

D

2D

2D

1D-WAP

W

1D-GWAP

2D

2D

W2 D

1D-WAP

D

D

D

W2D

D

D

1D-WAP1D-WAP 2D

D

D

2D

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR CB-6D.

1/01-TN100E1/01-TN100H

1/01-TN100D

/0

-T

N D

1/01-TN100H

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA G - TECHNOLOGY

01-TN100G

-2

-1

-T

N G

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA G - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

UP

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR AB-5A.

1/01-TN100E

1/01-TN100G

1/01-TN100F1/01-TN100J

1/01-TN100D

1/01-TN100J

1/01-TN100G

/0

-T

N F

1/01-TN100E

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA H - TECHNOLOGY

01-TN100H

-2

-1

-T

N H

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA H - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

2,807 SF

77 SF

61 SF

163 SF

M.A.S. WORK ROOM

RECORDS STORAGE

LOBBY

ELEVATOR

EQUIPMENT

STAIR #9

AB-2

AB-4

AB-3

SB-09-1

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR AB-5A. 1

/0 -T

N F

/0

-T

N F

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - BASEMENT PLAN -

AREA J - TECHNOLOGY

01-TN100J

-2

-1

-T

N J

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - BASEMENT PLAN - AREA J - TECHNOLOGY

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

IN

TERC

OM

IN

TERC

OM

INTERCOMINTERCOM

AC-12

AC-14

AC-20

AC-13

HANDRAIL

PASS-THRU

FIRE

CLOSET

ROLL-UP

OVERHANG

FROM CEILING

D O W N

STL.

RAILING

STL.

RAIL

UP

DOWN

DOWNTO

PIPE

BASEMENT

DOWN

DOWN UP

DOWN

UP

U P

U P

WHEEL CHAIR

RAMP

WHEEL CHAIR

RAMP

U P

D N

UP

STEPS

CONC.

DOWN

STEEL

RAIL

D N

UP

DN

DN

@ 5%

SLOPE

S L O P E

SLOPE

@ 5%

STAIRS

D O W N

U P

D N

UP

SELECTIVE

VERTICAL

SVC-1

DUMBWAITERS

D W

#1

D W

#2

GVC-3

GVC-4

1 2 3

1 2 3

FD FD

SLOPE

AREA

DRAIN

F.D.

F.D.

AREA

DRAIN

AREA

DRAIN

PITCH 2

3/4"

SUMP SEE

DETAILTHIS

SHEET

PITCH

F.D.

PITCH

F.D.

FD

FD FD

FD

FD

FD

FD

FD

FD

FD FD

FD

FD

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

PITCH

2"

PITCH

2"F.D.

F.D.

F.D.

F.D.F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.F.D.

F.D.

F.D. F.D.

F.D.

F.D.

CENTRAL DUCT

SHAFT

LOADING

DOCK

RTU

CORRIDOR

PIPE/ELECT

CHASE

MATERIALS LIFT

TELE CLOSET

TELE CLOSET

ELECTRICAL

STAIR #22

BIOMED SHOP

BIOMED SHOP

BIOMED SHOP

ELECTRONICS SHOP

ELECTRONICS

SHOP

ELECTRONICS

SHOP

ELECTRONICS

SHOP

STAIR #8

ELECTRONICS SHOP

SAFETY

SAFETY

SAFETY

SAFETY

SAFETY

SAFETY

CORRIDOR

H.A.C.

FIRE CORRIDOR

LAB SPECTOMETER

LAB SPECTOMETER

MORGUE

MORGUE

MECHANICAL

STAIR #13

BARBER SHOP

MEZZANINE

ELECTRICAL

MORGUE

H.A.C.

MENS RESTROOM

WOMENS RESTROOM

SAFETY

MORGUE

WOMENS LOCKERS

WOMENS RESTROOM

AND SHOWERS

MENS LOCKERS

WOMENS LOCKERS

MENS RESTROOM

AND SHOWERS

AMMS ----

MENS LOUNGE

WOMENS LOUNGE--------

TELEPHONE

LOGISTICS STORAGE

FIRE

MH TEAM

GROUP ROOM

EMPLOYEE GYM

MH ADMIN

(SWING)

CONFERENCE/

TRAINING

POOL SERVICE ROOM

OFFICE

MH INTERN

EDUCATION

OFFICE

MULTI-PURPOSE

TRAINING

CENTER

CONFERENCE/

TRAINING

MENS RESTROOM

SHOWERS AND LOCKERS

WOMENS RESTROOM

SHOWERS AND LOCKERS

FIRE

CHIEF

NURSE MH

M.A.T. ADMIN

POLICE

CORRIDOR

FIRE

WOMENS RESTROOM

MENS RESTROOM

PATIENT RECORD

FILE ROOM

LOBBY

STORAGE

STAIR #9

ELECTRICAL

MECHANICAL

EMERGENCY ELECTRICAL

TELECOMMUNICATIONS

SIGNAL

DOCTORS

WORKROOM

DOCTORS

WORKROOM

RELEASE OF INFORMATION

ELECTRICAL

RESTROOM

FIRE CORRIDOR

ELECTRICAL

OLD GRAPHIC CONTROL

A/C & REFRIGERATION

/SHEET METAL SHOP

ATS ROOM

SERVICE ROOM

---- ELECTRICAL

FIRE

SIGNAL

TELEPHONE

MHBS

IT CLOSETCORRIDOR

EDUCATION

EQUIPMENT

STORAGE

PSA MH CONFERENCE ROOM

MHBS

MHBS

MHBS MHBS MHBS

WOMENS RESTROOM

CORRIDOR

MHBSMHBS

WAITING

CORRIDOR

MECHANICAL

TEMPORARY STORAGE

MECHANICAL

MECHANICAL

TELEPHONE ELECTRICALOFFICE EMSSTORAGE

UNIFORM EXCHANGE

STORAGECORRIDOR

IMS IMS

IMS

OFFICE STAFF EMSOFFICE STAFF

EMS NIGHT

OFFICE EMS

N&FSN&FS

UNION OFFICE

LINEN ROOM

CORRIDOR STORAGE

WOMENS RESTROOM

ELECTRICAL

CORRIDOR

UNION OFFICE

UNION OFFICE

IMS

MECHANICAL

IMSIMS CHIEF OFFICE

SYSTEMS MANAGER

OFFICE IMS

ASST. SYSTEM MANAGER

OFFICE IMS

PC REPAIR----

OFFICE IMS

OFFICE

CORRIDOR

OFFICE IMS

SIGNAL

POWERSTAIR #5

COMPUTER ROOM

TELEPHONE

ELECTRICAL

MECHANICAL

MECHANICAL ----

SPD AMMS

ELEVATOR LOBBY

FIRE

SPD AMMS

SIGNAL

TELEPHONE

STAIR #3

CORRIDOR

RESEARCH

ELECTRICAL

ELEVATOR LOBBY

OFFICE

VAULT

ELEVATOR LOBBY

STERILE HAZ BUFFER

HAZ ANTE

HAZ

STORAGE

MAIN KITCHEN

FAMILY RESTROOM

TELEPHONE

SIGNAL

MECHANICAL

3T MRI

EQUIPMENT ROOM

CONTROL ROOM

OFFICE

OFFICE

CONTROL

ROOM

MRI

GURNEY STAGE

MECHANICAL

WAITING

RESTROOM

BREAK ROOM

OFFICE

OFFICE

WORK ROOM

OFFICE

OFFICE

RESTROOM

EXAM

DRESSINGDRESSING

RECEPTION

MAGNETIC TAPE

STAIR #21 MECHANICAL

LOCKERS

REPRODUCTION

MAIL ROOM

OFFICE PHARMACY

PHARMACY OUT PATIENT

OFFICE PHARMACY

ELECTRICALOFFICE PHARMACY

OFFICE PHARMACY

---- CORRIDOR CORRIDOR FIRE

MAIL

SUPERVISOR

REFRIGERATION

EQUIPMENT

PROCESS STORES

OFFICE WAREHOUSE

MEDICAL GASES

MEDICAL GASES

CLOSET

TRASH COLLECTION

BREAK AREA

STAIR #12

WAREHOUSE ADDITION

EMS SUPPLIES

STAIR #6

WAREHOUSE

N&FS OFFICE

N&FS OFFICE

FOOD PRODUCTION

OFFICE

DIETETIC

CLASSROOM

OFFICE N&FS

OFFICE N&FS OFFICE N&FS

WOMENS RESTROOM

TELEPHONE

MENS RESTROOM

FIRE ELECTRICAL

SIGNALELECTRICAL

CONSTRUCTION

LAYDOWN

CANTEEN VENDING

CORRIDOR

PEST CONTROL

SPS OFFICES

DISHWASHER

CART WASH

H.A.C.

FREEZER REFRIGERATOR

COOKS REFRIGERATOR

VEGETABLE

REFRIGERATOR

MEAT REFRIGERATOR

GENERAL STORAGE

KITCHEN ENTRY

REFRIGERATOR

DAIRY & EGG

REFRIGERATOR

PATIENT LAUNDRY

KITCHEN STORAGEELECTRICAL

FREEZER

ELECTRICAL

DIETETICS OFFICE

DIETETICS OFFICE

DIETETICS OFFICE

FROZEN FOOD HOLDING

INGREDENT CONTROL

CORRIDOR

C O R R

ID

O R

S

TA

IR

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

S

TA

IR

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

S

TA

IR

#2

C O R R

ID

O R

C O R R

ID

O R

S

TA

IR

C O R R

ID

O R

ELEVATOR LOBBY

S

TA

IR

C O R R

ID

O R

S

TA

IR

ELECTRICAL

IMS

OFFICE IMS

RESTROOM

WORKSTATIONS

BULK BREAKDOWN AREA

STORAGE

STORAGE

OFFICE

STERILE

STORAGE

STERILIZER

UNLOADING

STERILIZERS

ETO STERILIZERS/

AERATOR ROOM

CART

STORAGE

PREP. ASSEMBLY

STERILIZATION

H.A.C.

RESTROOM

LOCKER

ROOM

LOCKER

ROOM

RESTROOM

ANTE ROOM

ANTE ROOM

DECON

ANTE ROOM

MANUAL

WASH

SOILED RECEIVING/

DECON AREA

DECON

TOILET

H.A.C.

MECH.

PHARMACY

STORAGE

PREP HOLD

ELECTRICAL

RESTROOM

OFFICE

NON-HAZ

ANTE

STERILE NON-HAZ BUFFER

CREDIT UNION

CREDIT UNION

CREDIT UNION

CREDIT UNION

CORRIDOR

CREDIT UNION

GD-040

S0-22-1

GD-024

GD-022

GD-022a

GD-0??

GD-023d

GD-023c GD-023b GD-023a

GD-023

S0-08-1

GD-023e

GD-017b GD-017c

GD-017d

GD-017e

GD-017f

GD-017

C0-17-1

GD-018

GD-018a C0-16-1

GD-020a

GD-020

GD-027

GD-026a

GD-036

S0-13-1

GD-036a

GD-036b

GD-031a

GD-031

GD-025

GD-029

GD-030

GD-017a

GD-026

GD-013a

GD-013c

GD-015a

GD-013b

GD-015b

GD-014a GD-014

GD-015

GD-013GD-012lGD-010d

GD-010a

GD-010c

GD-010

GD-010b

GA-004b

GA-004b

GA-004

GA-004c

GA-004d

GA-012

GA-011a

GA-012aGA-013aGA-027n

GA-027o

GA-013

GA-013a

GA-009

GA-011b

GA-009a

GA-014

GA-004a

GA-007

C0-05c-1

GA-027l

GA-027m

GA-027h

GA-027h

GA-027

GA-027t

GA-027w

S0-09-1

GE-002

GE-001

GE-003

GE-004

GE-005

GA-027s GA-027r

GA-024

GA-023d

GA-025

GA-024a C0-05a-1

GA-023c

GA-023

BA-023a

AB-6b

AB-6c

BA-023b

GA-022 GA-021

GA-016a

GA-016c GA-016b

GA-006a

GA-016dC0-05-1

GA-015

GA-010 GA-008

GA-005a

GA-005

GA-006 GA-018 GA-017

GD-009

C0-09-1

GA-002GA-003

GA-027a

C0-05-1

BB-001a

AB-6d

BB-001b

BB-001

GB-017 GB-015GB-039aGB-038

GB-039

GB-027dC0-01-1

GB-029 GB-027f

GB-027

GB-030aGB-030GB-034

GB-031GB-033

GB-035

GB-036

C0-01b-1 GB-020b

GB-014

GB-013

C0-01c-1

GB-020

GB-020a

GB-020c

GB-021e

GB-027aGB-027b

GB-025a

GB-022

GB-025

GB-021a

GB-021GB-022a

GB-023b

GB-024f

C0-03-1

GB-024b

GB-024

GB-024c

GB-024dS0-05-1

GB-026

GB-026a

GB-026b

GB-027c

GB-011 GB-010

GC-003

GC-002

GD-003?

GD-003s

GC-003

GD-003t

GD-003e

S0-03-1

C0-xx-1

GA-029k

GD-003e?

GA-030

GA-029

GA-029a

GA-029j

GD-002

GA-029f

GA-029e GA-029d

GD-007o

GD-007

GD-011

GC-051

GC-052

GC-028b

GC-027

GC-028a

GC-028

GC-030

GC-031

GC-035

GC-034

GC-024

GC-032

GC-036

GC-020

GC-025

GC-026a

GC-043

GC-045

GC-026

GC-046

GC-047

GC-044

GC-023

GC-022bGC-022a

C0-18-1

GC-021

GC-049

S0-21-1 GC-050

GC-048

GC-008g

GC-008h

GC-008f

GC-008

GC-008b

GC-008dGC-008a

GC-008c

GC-006l C0-07a-1 C0-07b-1 GC-004g

GC-008i

GC-004b

GC-004a

GC-004c

GC-009

GC-010

GC-011

GC-004d

GC-0xx

GC-012

GC-012a

GC-004j

S0-12-1

GC-004f

GC-004e

S0-06-1

GC-004

GD-007t

GD-007u

GD-007j

GB-037b

GD-037a GD-037c GD-037

GD-035

GD-039b

GD-034

GD-038d

GD-039a GD-039

GD-039cGD-0xx

GD-038c

GD-038

GD-038f

GD-008

GD-038a

GD-038e

C0-09a-1

GD-012a

GD-012b

GD-012c

GD-012d

GD-012

GD-038g

GD-007m

GD-007a

GC-006

GC-007w GC-007v

GD-007b

GD-007c

GD-007d

GD-007p GD-007r

GD-007n

GD-007s

GD-007g

GC-007

GC-007bGC-007a

GD-007q

GC-005

GC-001a

GC-001b

GD-005

GD-007e

GD-007f

C0-14-1C 5b

S

C 5d

C 1a

C 6a

S

C

C

C

C 1-

C

C

C 6a

C

C

S

C

C

C 1b

S

C

GD-001

S xx

C

S

GB-020d

GA-0xx

GC-004i

GC-004h

GA-008a

GD-054

GD-053

GD-051a

GD-052

GD-050

GD-051

GD-051b

GD-043b

GD-043

GD-042

GD-042b

GD-041

GD-045

GD-046

GD-049

GD-047

GD-047a

GD-047b

GD-047c

GC-004k

GC-024

GC-033

GA-016

GA-029c GA-029b

GA-029e

G-029g

GA-029

GA-029

GD-032

GD-033b

GD-033

GD-033a

C0-11a-1

GD-033c

CHAIN

P L E N U M

PASS-THRU

WINDOW

ABOVE

METAL

DECK

TO

CLG

CLOSED

OFF

CLOSED

OFF

4" WASTE

PIPE

9' CEILINGS

7'11" CEILINGS

EXISTING TR

01-TN304

G16

01-TN305

G16

A12/01-TN101A

A /0

-T

N A

A12/01-TN101B

A12/01-TN101B

A12/01-TN101C

A /0

-T

N D

A12/01-TN101D

A12/01-TN101E

A12/01-TN101E

A12/01-TN101F

A /0

-T

N D

A12/01-TN101D

A12/01-TN101E

A12/01-TN101E

A12/01-TN101F

A /0

-T

N G

A12/01-TN101G

A12/01-TN101H

A12/01-TN101H

A12/01-TN101J

PW-CPW-1

(TYP. OF 4)

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A ON

THE FLOOR BELOW.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

TR GD-010D

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

TR GB-010

(4) 4"CONDUITS

PW-CPW-1

(TYP. OF 4)

(4) 4"CONDUITS

EXISTING CABLE TRAY

PATHWAY UP TO LEVEL 1

EXISTING CABLE TRAY

01-TN318

F16

01-TN320

DOWN TO

BASEMENT UP

TO FIRST LEVEL

20 B-LEG FIBER UP

4 B-LEG FIBER DOWN

24 B-LEG FIBER

26 A LEG FIBER

A LEG FIBER

FROM LEVEL

ABOVE

B-LEG FIBER

39 B-LEG FIBER

A-LEG FIBER

FROM LEVEL

BELOW

B

B

B

B

B

B

B

B B

BB

A-LEG FIBER

FROM ABOVE

A-LEG TO

BUILDING 30, 77,

EXISTING CABLE TRAY

(72) A-LEG UP TO FIRST FLOOR

B-LEG FIBER TO

ROUTE TO TR ABOVE

B

A

A & B LEG FIBER

TO BUILDING 42

B

A

(4) 4" CONDUITS FROM CB-6F

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR CB-6F

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A ON

THE FLOOR BELOW.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR CB-6F

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - OVERALL

GROUND FLOOR PLAN -

TECHNOLOGY

01-TN101

-2

-1

-T

N

/0

/2

.p d f

N

BUILDING

NORTH

N

TRUE

NORTH

3/64" = 1'-0"

BUILDING 01 - OVERALL GROUND FLOOR PLAN - TECHNOLOGY

A12

NOTES:

1. THIS OVERALL PLAN IS FOR REFERENCE ON SERVICING AREAS, TELECOMMUNICATION ROOM LOCATIONS, AND PATHWAY. REFER TO THE AREA PLANS FOR ADDITIONAL INFORMATION.

Revisions: Date:

Revision 2 4/14/2026

HANDRAIL

U P

D N

UP

STEPS

CONC.

DOWN

STEEL

RAIL

D N

F.D.

PITCH

2"

PITCH

2"F.D.

F.D.

F.D.

F.D.F.D.

LOADING

DOCK

REPRODUCTION

MAIL ROOM

MAIL

SUPERVISOR

REFRIGERATION

EQUIPMENT

PROCESS STORES

OFFICE WAREHOUSE

MEDICAL GASES

MEDICAL GASES

CLOSET

TRASH COLLECTION

BREAK AREA

STAIR #12

WAREHOUSE ADDITION

EMS SUPPLIES

STAIR #6

WAREHOUSE

S

TA

IR

S

TA

IR

RESTROOM

WORKSTATIONS

BULK BREAKDOWN AREA

STORAGE

STORAGE

PHARMACY

STORAGE

GC-008g

GC-008h

C0-07b-1 GC-004g

GC-008i

GC-004b

GC-004a

GC-004c

GC-009

GC-010

GC-011

GC-004d

GC-0xx

GC-012

GC-012a

GC-004j

S0-12-1

GC-004f

GC-004e

S0-06-1

GC-004

S xx

S

GC-004i

GC-004h

GC-004k

D

2D

D

D

1D-WAP

1D-WAP

1D-GWAP

1D-WAP

D

2D

D

2D

D

1D-WAP

1D-GWAP

2D 2D 2D

2D

D2D2D

2D

2D

2D2D

2D2D2D

D

D

D

D

D 2 D

D

D2 D

1D-GWAP

D2 D

2D 2D 2D 2D

2D 2D2D

2D 2D

1D-WAP

2D

D

D

D

D

W

D

D

2D

2D

1D-GWAP

W W

1D-WAP

W

D 2 D2 D

D

2D

2D

D

D

2D2D

W

D

1D-GWAP

2D

2D

W

1D-CAM

1D-WAP

PROPOSED

TELECOM ROOM

EXISTING SECURITY PANEL

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR CB-6F.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

A12/01-TN101BA12/01-TN101E

A12/01-TN101D

A /0

-T

N D

A12/01-TN101B

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - GROUND FLOOR

PLAN - AREA A - TECHNOLOGY

01-TN101A

-2

-1

-T

N A

/0

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - GROUND FLOOR PLAN - AREA A - TECHNOLOGY

A12

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

D O W N

STL.

RAILING

STL.

RAIL

STEPS

CONC.

STEEL

RAIL

FD

SLOPE

F.D.

ELECTRICAL

BARBER SHOP

MEZZANINE

ELECTRICAL

CORRIDOR FIRE

MAIL

SUPERVISOR

MEDICAL GASES

N&FS OFFICE

N&FS OFFICE

FOOD PRODUCTION

OFFICE

GENERAL STORAGE

KITCHEN ENTRY

REFRIGERATOR

DAIRY & EGG

REFRIGERATOR

PATIENT LAUNDRY

KITCHEN STORAGE

INGREDENT CONTROL

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

RESTROOM

ANTE ROOM

DECON

ANTE ROOM

SOILED RECEIVING/

DECON AREA

DECON

TOILET

H.A.C.

MECH.

GD-040

GD-027

GD-036a

GD-036b

C0-07b-1 GC-004g

GC-008i

GC-010

GD-007t

GD-007u

GD-007j

GD-037c GD-037

GD-007p GD-007r

GD-007n

GD-007s

GD-007g

GC-007

GC-007b

GD-007f

C

C 1-

C

GD-042b

GD-041

GD-046

GD-047

GD-047a

GD-047b

GD-047c

CHAIN

D

D

D

D

D

2D

D

1D-GWAP

1D-CAM

2D

W

1D-WAP

1D-GWAP

1D-WAP

1D-CAM

1D-CAM

1D-CAM

1D-GWAP

D

2D 2D W

2D 2D

2D

W

1D-CAM

W

W

2D

W

2D2DW

1D-WAP

D

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A.

A12/01-TN101E

A12/01-TN101D A12/01-TN101AA12/01-TN101A

A12/01-TN101E

A12/01-TN101F A12/01-TN101C A12/01-TN101C

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A ON

THE FLOOR BELOW.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - GROUND FLOOR

PLAN - AREA B - TECHNOLOGY

01-TN101B

-2

-1

-T

N B

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - GROUND FLOOR PLAN - AREA B - TECHNOLOGY

A12

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

STAIRS

D O W N

U P

GVC-3

GVC-4

FD FD

AREA

DRAIN

MATERIALS LIFT

TELE CLOSET

STAIR #22

BIOMED SHOP

BIOMED SHOP

BIOMED SHOP

ELECTRONICS SHOP

ELECTRONICS

SHOP

ELECTRONICS

SHOP

ELECTRONICS

SHOP

STAIR #8

ELECTRONICS SHOP

SAFETY

SAFETY

SAFETY

SAFETY

SAFETY

SAFETY

CORRIDOR

H.A.C.

FIRE CORRIDOR

LAB SPECTOMETER

LAB SPECTOMETER

MORGUE

MORGUE

MECHANICAL

STAIR #13

MORGUE

H.A.C.

MENS RESTROOM

WOMENS RESTROOM

SAFETY

MORGUE

WOMENS LOCKERS

WOMENS RESTROOM

AND SHOWERS

MENS LOCKERS

WOMENS LOCKERS

MENS RESTROOM

AND SHOWERS

AMMS ----

MENS LOUNGE

WOMENS LOUNGE

OFFICE N&FS

OFFICE N&FS OFFICE N&FS

WOMENS RESTROOM

TELEPHONE

MENS RESTROOM

FIRE ELECTRICAL

SIGNAL

CORRIDOR

S

TA

IR

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

STERILE

STORAGE

STERILIZER

UNLOADING

STERILIZERS

ETO STERILIZERS/

AERATOR ROOM

CART

STORAGE

PREP. ASSEMBLY

STERILIZATION

H.A.C.

RESTROOM

LOCKER

ROOM

LOCKER

ROOM

RESTROOM

ANTE ROOM

DECON

ANTE ROOM

MANUAL

WASH

CREDIT UNION

CREDIT UNION

CREDIT UNION

CREDIT UNION

CORRIDOR

CREDIT UNION

S0-22-1

GD-024

GD-022

GD-022a

GD-0??

GD-023d

GD-023c GD-023b GD-023a

GD-023

S0-08-1

GD-023e

GD-017b GD-017c

GD-017d

GD-017e

GD-017f

GD-017

C0-17-1

GD-018

GD-018a C0-16-1

GD-020a

GD-020

GD-027

GD-026a

GD-036

S0-13-1

GD-031a

GD-031

GD-025

GD-029

GD-030

GD-017a

GD-026

GD-013a

GD-013c

GD-015a

GD-013b

GD-015b

GD-014a GD-014

GD-015

GD-013

GD-037a GD-037c GD-037

GD-035

GD-039b

GD-034

GD-038d

GD-039a GD-039

GD-039c

GD-038g

C0-14-1

S 1-

C

C

C

GD-054

GD-053

GD-051a

GD-052

GD-050

GD-051

GD-051b

GD-043b

GD-043

GD-042

GD-045

GD-049

GD-032

GD-033b

GD-033

GD-033a

C0-11a-1

GD-033c

D

1D-WAP

D

D

1D-WAP

D

2D2DW

2D

D

D

D

D 2

D D

W

D

D

D

1D-WAP

1D-WAP

2D2D

W

1D-GWAP

1D-WAP

1D-GWAP

D

2D 2D 2 D

D

1D-CAM

1D-GWAP

D

2D

D

1D-WAP

2D

D

2D

1D-GWAP

D

1D-WAP 1D-CAM

D

2D

D

D

1D-GWAP

1D-WAP

D

D2D

2D W

2D

2D2 D

D

2D 2D

1D-WAP

1D-CAM

2D 2D

2D

2D 2D

2D

2D

D

1D-GWAP

D

1D-WAP

D

D

D

D

D

D 2D 2D W W

1D-GWAP 1D-WAP

D

D

D

2D 2D

2D

2D

D

D

D

D

D

D

D

2D

2D

2D

2D

D

D

D 2D

2D

2D

2D

D

D

D

PROPOSED

TELECOM ROOM

EXISTING TR

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A ON

THE FLOOR BELOW.

A12/01-TN101E

A12/01-TN101F

A /0

-T

N F

A12/01-TN101B A12/01-TN101B

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR DB-5A ON

THE FLOOR BELOW.

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - GROUND FLOOR

PLAN - AREA C - TECHNOLOGY

01-TN101C

-2

-1

-T

N C

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - GROUND FLOOR PLAN - AREA C - TECHNOLOGY

A12

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

AC-14

U P

U P

WHEEL CHAIR

RAMP

WHEEL CHAIR

RAMP

D N

UP

DN

S

LO

P E

F.D.

F.D.

F.D.

F.D.

F.D.

F.D. F.D.

F.D.

F.D.

F.D.

F.D.F.D.

RTU

CORRIDOR

TELE CLOSET

MECHANICAL

TELEPHONE ELECTRICALOFFICE EMSSTORAGE

UNIFORM EXCHANGE

STORAGE

IMS IMS

IMS

CORRIDOR STORAGE

WOMENS RESTROOM

ELECTRICAL

CORRIDOR

UNION OFFICE

UNION OFFICE

IMS

MECHANICAL

IMSIMS CHIEF OFFICE

SYSTEMS MANAGER

OFFICE IMS

ASST. SYSTEM MANAGER

OFFICE IMS

PC REPAIR----

OFFICE IMS

OFFICE

CORRIDOR

OFFICE IMS

SIGNAL

POWERSTAIR #5

ELECTRICAL

MECHANICAL

MECHANICAL ----

SPD AMMS

TELEPHONE

SIGNAL

MECHANICAL

3T MRI

EQUIPMENT ROOM

CONTROL ROOM

OFFICE

OFFICE

CONTROL

ROOM

MRI

GURNEY STAGE

MECHANICAL

WAITING

RESTROOM

BREAK ROOM

OFFICE

OFFICE

WORK ROOM

OFFICE

OFFICE

RESTROOM

EXAM

DRESSINGDRESSING

RECEPTION

MAGNETIC TAPE

STAIR #21 MECHANICAL

LOCKERS

REPRODUCTION

MAIL ROOM

OFFICE PHARMACY

PHARMACY OUT PATIENT

OFFICE PHARMACY

ELECTRICALOFFICE PHARMACY

OFFICE PHARMACY

MAIL

SUPERVISOR

C O R R

ID

O R

S

TA

IR

C O R R

ID

O R

C O R R

ID

O R

IMS

OFFICE IMS

STORAGE

STORAGE

PREP HOLD

BB-001b

GB-017 GB-015GB-039aGB-038

GB-039

GB-027d

GB-029 GB-027f

GB-027

C0-01b-1 GB-020b

GB-014

GB-013

C0-01c-1

GB-020

GB-020a

GB-020c

GB-021e

GB-027aGB-027b

GB-025a

GB-022

GB-025

GB-021a

GB-021GB-022a

GB-023b

GB-024f

C0-03-1

GB-024b

GB-024

GB-024c

GB-024dS0-05-1

GB-026b

GB-027c

GB-011 GB-010

GC-003

GC-002

GC-051

GC-052

GC-028b

GC-027

GC-028a

GC-028

GC-030

GC-031

GC-035

GC-034

GC-024

GC-032

GC-036

GC-020

GC-025

GC-026a

GC-043

GC-045

GC-026

GC-046

GC-047

GC-044

GC-023

GC-022bGC-022a

C0-18-1

GC-021

GC-049

S0-21-1 GC-050

GC-048

GC-008g

GC-008h

GC-008f

GC-008

GC-008b

GC-008dGC-008a

GC-008c

GC-006l C0-07a-1 C0-07b-1

GC-008i

C

S

C

C

C 1b

GB-020d

GC-024

GC-033

PASS-THRU

WINDOW

ABOVE

METAL

DECK

D

2D

2D 2D 2D 2D

1D-WAP

D

2D 2D

2D

W

D

2D 2D

D

D

D

D

D

2D 2D

D

1D-WAP

2D

D

D

D

D

D

D

D

2D 2D

D

2D2D

D

1D-GWAP

1D-CAM

2D2D2D

D

D

D

D

D

D

D

D

D

D

D

D

1D-WAP

1D-GWAP

2D

2D2D2D

2D

2D

D

D

2D

D

2D 2D 2 D

D

D

D

2D2D

2D2D

2D

1D-CAM

D

D

D

2D 2D

1D-WAP

2D

2D 2D W1D-CAM

1D-WAP

1D-GWAP

2D

1D-CAM 1D-WAP

D

D

1D-GWAP

W 2D 2D W 2D

1D-WAP

1D-CAM

2D

1D-GWAP 1D-CAM

1D-CAM

1D-WAP

2D

2D

2D

2D

2D

2D

2D

D

D

D

D

2D2D2D2D2D

D

D

D

D

W

2D

1D-CAM1D-CAM

2D

D

1D-CAM

D

D

2D

2D

2D

D

2D W

2D 2D

D

2D

2D

2D 2D

2D 2D

D

D

2D

2D2D

D

1D-CAM

1D-CAM

1D-WAP

W

1D-WAP

D

2D 2D

2D2D

1D-GWAP

2D

2D

D

D

W

1D-GWAP1D-GWAP

D

D

D

D

2D 2D2D2D2D2D 2D

1D-CAM1D-CAM

2D

D

1D-GWAP

2D

W

W 2D

2D

2D

W

1D-GWAP

W

EXISTING TR

01-TN304

G16

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

A12/01-TN101E

A12/01-TN101A

A12/01-TN101B

A /0

-T

N A

A12/01-TN101EA12/01-TN101H

A12/01-TN101G

A /0

-T

N G

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-2430

04/04/2025

673-20-107

BARPDN

EHRM INFRASTRUCTURE UPGRADE

TAMPA, FL.

ISSUED FOR CONSTRUCTION

BUILDING 01 - GROUND FLOOR

PLAN - AREA D - TECHNOLOGY

01-TN101D

-2

-1

-T

N D

/1

/2

.p d f

1/8" = 1'-0"

BUILDING 01 - GROUND FLOOR PLAN - AREA D - TECHNOLOGY

A12

N

BUILDING

NORTH

N

TRUE

NORTH

NOTES:

1. REFER TO TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY GENERAL NOTES, TECHNOLOGY

INSTALLATION NOTES AND SYMBOL LIST.

2. REFER TO TN700 FOR GENERAL TECHNOLOGY EQUIPMENT SCHEDULE.

3. CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION OUTLETS

IN THEIR PROPOSAL FOR THIS SHEET. FUTURE INFORMATION OUTLET LOCATIONS WILL BE DETERMINED BY

THE VA AT A LATER DATE.

4. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO INSTALLATION.

5. ALL INFORMATION OUTLETS ON THIS SHEET TO BE CABLED ON A SCHEDULED BASIS WITH OWNER WHILE

OCCUPIED WITH STAFF AND PATIENTS. COORDINATE DEMO AND CABLE REPLACEMENT WITH OWNER.

6. CONTRACTOR TO PROVIDE NEW J-HOOK ROUTES FOR ALL NEW CABLING. J-HOOK SIZE AND QUANTITY TO

BE PER MANUFACTURER RECOMMENDATIONS. EXISTING CABLE TRAY MAY BE USED IF ACCESSIBLE WITH

SPARE CAPACITY.

Revisions: Date:

Revision 2 4/14/2026

IN

TERC

O M

IN

TERC

O M

INTERCOMINTERCOM

AC-12

AC-14

AC-20

AC-13

OVERHANG

FROM CEILING

DOWNTO

PIPE

BASEMENT

DOWN

SELECTIVE

VERTICAL

SVC-1

D W

#1

D W

#2

1 2 3

F.D.

F.D.

FD

FD

FD

FD

FD

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D. F.D.

F.D.F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.

F.D.F.D.

F.D.

F.D. F.D.

F.D.

F.D.

PIPE/ELECT

CHASE

TELE CLOSET

ELECTRICAL

OLD GRAPHIC CONTROL

A/C & REFRIGERATION

/SHEET METAL SHOP

ATS ROOM

SERVICE ROOM

---- ELECTRICAL

FIRE

SIGNAL

TELEPHONE

IT CLOSETCORRIDOR CORRIDOR

MECHANICAL

TEMPORARY STORAGE

MECHANICAL

ELEVATOR LOBBY

FIRE

SPD AMMS

SIGNAL

TELEPHONE

STAIR #3

CORRIDOR

RESEARCH

ELECTRICAL

ELEVATOR LOBBY

OFFICE

VAULT

ELEVATOR LOBBY

STERILE HAZ BUFFER

HAZ ANTE

HAZ

STORAGE

MAIN KITCHEN

---- CORRIDOR CORRIDOR

MAIL

SUPERVISOR

DIETETIC

CLASSROOM

OFFICE N&FS

CANTEEN VENDING

DISHWASHER

CART WASH

H.A.C.

FREEZER REFRIGERATOR

COOKS REFRIGERATOR

VEGETABLE

REFRIGERATOR

MEAT REFRIGERATOR

GENERAL STORAGE

KITCHEN STORAGEELECTRICAL

FREEZER

ELECTRICAL

DIETETICS OFFICE

DIETETICS OFFICE

DIETETICS OFFICE

FROZEN FOOD HOLDING

INGREDENT CONTROL

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

C O R R

ID

O R

ELEVATOR LOBBY

RESTROOM

OFFICE

NON-HAZ

ANTE

STERILE NON-HAZ BUFFER

GA-023c

GA-023

BA-023a

AB-6b

AB-6c

BA-023b

GA-022 GA-021

GA-016a

GA-016c GA-016b

GA-016dC0-05-1 C0-05-1

BB-001a

AB-6d

BB-001

GC-002

GD-003?

GD-003s

GC-003

GD-003t

GD-003e

S0-03-1

C0-xx-1

GA-029k

GD-003e?

GA-030

GA-029

GA-029a

GA-029j

GD-002

GA-029f

GA-029e GA-029d

GD-007o

GD-007

GC-006l C0-07a-1 C0-07b-1

GC-008i

GB-037b

GD-037a

GD-008

GD-007m

GD-007a

GC-006

GC-007w GC-007v

GD-007b

GD-007c

GD-007d

GD-007p

GC-007bGC-007a

GD-007q

GC-005

GC-001a

GC-001b

GD-005

GD-007e

GD-007f

C 1a

C a-

C a-

C

GD-001

GA-029c GA-029b

GA-029e

G-029g

GA-029

GA-029

P L E N U M

D

D

D

2D2D2D2D2D

W

2D

1D-CAM1D-CAM

2D

D

1D-GWAP

D

1D-GWAP

1D-CAM1D-CAM

1D-WAP

2D

D

D

2D

2D

D

1D-WAP

2D2D

2D 2 D

D

1D-WAP

W

2D2D2D

2D

D

D

1D-WAP

2D 2D 2D1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM

1D-CAM1D-GWAP

1D-CAM1D-CAM

1D-CAM

1D-CAM

D

D

2D 2D

D

D

D

D

D

D2D2D2D2D

D

D 2 D

2D

D

2D

D

1D-CAM

1D-GWAP

1D-WAP

1D-WAP

1D-CAM

1D-WAP

1D-CAM

W

D

2D

2D

2D D

D

D

2D

D

2D

D 2 D

D

2D

2D2D2D2D

2D 2D 2D 2D

1D-CAM1D-CAM

1D-GWAP

D

1D-WAP

1D-WAP

D

D

D

2D2D

D

D

D

1D-CAM

1D-WAP

D

D

D

D

2D 2D2D2D2D2D 2D

1D-CAM1D-CAM

2D

D

1D-GWAP

D

1D-CAM

D

D

2D2D

1D-CAM

1D-WAP

1D-CAM

D

2D2D

D

1D-CAM

1D-WAP

D

CONSTRUCTION

PROPOSED

TELECOM ROOM

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

A12/01-TN101D A12/01-TN101A

A12/01-TN101F A12/01-TN101C

A12/01-TN101B

A12/01-TN101BA12/01-TN101H

A12/01-TN101G A12/01-TN101D

A12/01-TN101FA12/01-TN101J

A12/01-TN101H

A /0

-T

N A

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GB-010.

ALL NEW LOW VOLTAGE

CABLING IN THIS AREA WILL

ROUTE TO TR GD-010D.

N

TRUE NORTH

SITE KEY PLAN

SCALE: NOT TO SCALE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

CONSULTANT:

COMPASS

8734 GALLOWAY TRAIL

NOVELTY, OH. 44072

619-925-1647

ARCHITECT:

CB DESIGN GROUP

950 N. WASHINGTON ST

SUITE 334

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd.

Tampa, FL. 33612

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

SCOTT PRZYBYSZ

15 SUNNEN DR. SUITE 104

ST. LOUIS, MO 63143

314-951-2535

CONSULTANT:

MARK DYCK

148 S. QUEEN ST. SUITE 201

MARTINSBURG, WV. 25401

304-266-3115

CONSULTANT:

CLARE KRAMER

2815 DIRECTORS ROW

SUITE 500

ORLANDO, FL. 32809

407-917-243…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .