This is a site restoration plan drawing (sheet CL701-N) for a steam tunnel construction project at a VA facility in Des Moines, IA. The drawing shows the north section of the construction area between several buildings including Building 3, Building 5, and Building 25.
The plan details restoration work required after steam tunnel installation, including bituminous pavement restoration, concrete sidewalk restoration, replacement of concrete curb and gutter, and turf restoration with sod. Multiple vault locations (#3, #4, and #5) are shown with access hatches and exhaust fan intakes. The drawing indicates areas for reinstallation of salvaged signs, light poles, and restriping of existing parking stalls. Construction limits, laydown/stockpile areas, and existing utilities (gas, electric, telephone, etc.) are clearly marked. The drawing includes technical details like elevation numbers and is dated August 9, 2024 as part of the 100% Final Bid Documents package, with Anderson Engineering of Minnesota, LLC serving as the designer of record.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMVET AVENUE
AMVET AVENUE
BUILDING 5
GARAGES
BUILDING 3
BUILDING 25
POTENTIAL
FUTURE BUILDING
LOCATION
EUCLID AVE
0.2
0.6
0.5
0.5
0.6
0.1
0.7
9.5
4.7
9.6
8.4
7.5
907.20
906.50
910.00
909.30
RIM=907.06
909.00
908.50
910.67
910.63
RIM
=9
.20 RIM
=9
.89
HP=9
.35
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
y
:\1
\1 v ac ih s de s m oi ne s-a e co ns tru ct s te am tu nn el c iv il\ _0 ca d fil es s he et s\
0_ l_ re st or at io n.
dw g ed it:
m m ill er s av ed
:2 /6
/2
8:
A
M p lo t:2
/6 /2
:1
P
M
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseDESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17270
CONSTRUCT STEAM
TUNNEL
636A6-23-101
SITE
08/09/2024
DES MOINES, IA
LRK
100% FINAL BID
DOCUMENTS
Date:
623 26TH AVENUE
ROCK ISLAND, IL 61201
9555 JAMES AVE S. SUITE 200
BLOOMINGTON, MN 55431
N
0 20' 40'
RESTORATION PLAN - NORTH
CL701-N
LIMIT OF CONSTRUCTION (TYP.)
TURF RESTORATION - SOD
(TYP.)
BITUMINOUS PAVEMENT
RESTORATION (TYP.)
CONCRETE SIDEWALK
RESTORATION (TYP.)
REPLACE CONC.
CURB & GUTTER
REPLACE CONC.
CURB & GUTTER
REPLACE CONC.
CURB & GUTTER
VAULT #5
VAULT #6
BITUMINOUS PAVEMENT
RESTORATION (TYP.)
BITUMINOUS PAVEMENT
RESTORATION (TYP.)
BITUMINOUS PAVEMENT
RESTORATION (TYP.)
VAULT #4
VAULT #3
CONCRETE SIDEWALK
RESTORATION
REPLACE CONC. CURB & GUTTER
TURF RESTORATION - SOD
(TYP.)
BN
REINSTALL SALVAGED SIGNS
REINSTALL SALVAGED SIGN
REINSTALL SALVAGED SIGNS
REINSTALL SALVAGED SIGNS
REINSTALL SALVAGED
LIGHT POLE
REINSTALL SALVAGED
LIGHT POLES
RESTRIPE EX.
PARKING STALLS
(SEE SHEET C702)
RESTRIPE EX. PARKING
STALLS (TYP.)
(SEE SHEET C702 FOR
STRIPING)
LEGEND
CONSTRUCTION LIMITS
LAYDOWN/STOCKPILE AREA
EXISTING FENCE
EXISTING GAS MAIN
EXISTING OVERHEAD WIRES
EXISTING TELEPHONE
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
EXISTING DECIDUOUS TREE
EXISTING CONIFER TREE
EXISTING LIGHT POLE
EXISTING SIGN
REINSTALL SIGN
REINSTALL LIGHT POLE
CURB & GUTTER RESTORATION
BITUMINOUS PAVEMENT RESTORATION
CONCRETE SIDEWALK RESTORATION
SOD RESTORATION
VAULT ACCESS HATCH
EXHAUST FAN INTAKE
EX. COMM VAULT
TO REMAIN
1.4%
PROPOSED CONCRETE CROSS
GUTTER (MATCH EXISTING)
VAULT ACCESS HATCH
VAULT ACCESS HATCHES
VAULT ACCESS HATCH
PROPOSED PERIMETER
RAILING (SEE DETAIL 4/C903)
PROPOSED PERIMETER
RAILING (SEE DETAIL 4/C903)
PROPOSED PERIMETER
RAILING (SEE DETAIL 4/C903)
REINSTALL SALVAGED SIGNS
EXHAUST FAN INTAKE
EXHAUST FAN INTAKE
EXHAUST FAN INTAKE
EXHAUST FAN INTAKE
5.98
12" RETAINING WALL
MATCH EXISTING
1 REVISION 1 02/07/2025
AutoCAD SHX Text
15KV
AutoCAD SHX Text
CO
AutoCAD SHX Text
GARY R. JOHNSON 18238
| Sheets and Views |
| RESTORATION PLAN - NORTH |