C902.pdf

PDF 1 MB Posted

Attached to
Z1DA--PN: 636A6-23-101 Construct Steam Tunnel (DM)
Solicitation number
36C26325R0017
Issued by

About this file

This is an engineering drawing (C902) showing civil details for a steam tunnel construction project at a VA facility in Des Moines, IA. The drawing is dated August 9, 2024, and is part of the 100% Final Bid Documents package.

The drawing includes detailed cross-sectional views and specifications for the steam tunnel construction, including typical tunnel cross sections, rip rap details at flared end sections, and water main crossing details for both overhead and floor configurations. Key technical specifications show a tunnel with varying depths of 6.5' to 8.0', incorporating 4" perforated HDPE drain tile, geofabric layers, crushed stone (3/4" to No. 4 per ASTM D448), and a 12" clay cap with restored surface. The water main crossings detail connections to existing 10" and 6" DIP watermains using various DIP bends (11-1/4° and 45°). The drawing includes specific measurements, elevations, and construction requirements for proper installation and waterproofing. Anderson Engineering of Minnesota, LLC is listed as the designer of record.

View the file

Other files

File Type Posted
Site Visit Sign-In Sheet.pdf PDF
36C26325R0017 0005.docx DOCX document
260541 Underground Electrical Construction - 9 pages.pdf PDF
232213 Steam and Condensate Heating Piping - 26 pages.pdf PDF
336300 Steam Energy Distribution - 40 pages.pdf PDF
334613 Foundation Drainage - 7 pages.pdf PDF
329000 Planting - 11 pages.pdf PDF
230923 Direct-Digital Control Systems for HVAC - 67 pages.pdf PDF
271323-13i Communications Optical Fiber Splicing and Terminations - 1 pages.pdf PDF
36C26325R0017 0004.docx DOCX document
02833313 Lead-Based Paint Removal Disposal - 13 pages.pdf PDF
271323i Communications Optical Fiber Backbone Cabling - 3 pages.pdf PDF
265600 Exterior Lighting - 5 pages.pdf PDF
36C26325R0017 0003.docx DOCX document
Wage Determination 2.7.25 - 7 pages.pdf PDF
636A6-23-101 Steam Tunnel Questions - 12 pages.pdf PDF
MP101.pdf PDF
MP501.pdf PDF
C401-S-2.pdf PDF
E104.pdf PDF
C501-N-1.pdf PDF
AE314.pdf PDF
Building 10 Addition 1973 - 9 pages.pdf PDF
AE312.pdf PDF
C601-N.pdf PDF
S201.pdf PDF
AE311.pdf PDF
C401-N-1.pdf PDF
CL701-N.pdf PDF
C401-N-2.pdf PDF
AE520.pdf PDF
MP104.pdf PDF
S001.pdf PDF
S202.pdf PDF
36C26325R0017 0002.pdf PDF
AE101-SB.pdf PDF
S203.pdf PDF
C201-N.pdf PDF
Building 10 Original Construction 1932 - 8 pages.pdf PDF
C401-S-1.pdf PDF
MP302.pdf PDF
E103.pdf PDF
MV402.pdf PDF
AE313.pdf PDF
E501.pdf PDF
AE521.pdf PDF
CD101-N.pdf PDF
Tremco Product Infomation.pdf PDF
Wage Determination 1.31.25 - 7 pages.pdf PDF
36C26325R0017 0001.docx DOCX document
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 v ac ih s de s m oi ne s-a e co ns tru ct s te am tu nn el c iv il\ _0 ca d fil es s he et s\

0_ c_ de ta ils

.d w g ed it:

m m ill er s av ed

:2 /6

/2

:1

A M p lo t:2 /6

/2

:2

P M

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseDESIGNER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17270

CONSTRUCT STEAM

TUNNEL

636A6-23-101

SITE

08/09/2024

DES MOINES, IA

LRK

100% FINAL BID

DOCUMENTS

Date:

623 26TH AVENUE

ROCK ISLAND, IL 61201

9555 JAMES AVE S. SUITE 200

BLOOMINGTON, MN 55431

CIVIL DETAILS

C902

CEILING

CENTERLINE

ELEV. FFE

4.0' 4.0'

SCALE:1 TYPICAL TUNNEL CROSS SECTION

NOT TO SCALE

8"

12" GRANULAR

GEOFABRICEXISTING SOIL

DRAINAGE COMPOSITE - SEE SPEC SECTION 07 12 00

NOTE: SEE STRUCTURAL PLANS FOR WALL,

FLOOR, AND CEILING THICKNESSES AND

STEEL REINFORCEMENT BAR PLACEMENT.

SCALE:2 RIP RAP AT FLARED END SECTION

NOT TO SCALE

8"

8"

4" PERFORATED

HDPE DRAIN TILE (TYP.)

SCALE:3 TYPICAL WATER MAIN CROSSING - OVERHEAD

NOT TO SCALE

SCALE:4 TYPICAL WATER MAIN CROSSING - FLOOR

NOT TO SCALE

CONNECT TO EX. 10" & 6"

DIP WATERMAINS (TYP.)

EX. 10" & 6" DIP

WATERMAINS

(2) 11-1/4° DIP

BENDS (TYP.)

SEE STRUCTURAL PLANS

FOR WALL PENETRATION

WATERPROOFING DETAILS

5.5'

(MIN.)

SEE ARCHITECTURAL PLANS

FOR WALL PENETRATION

WATERPROOFING DETAILS

(2) 45° DIP

BENDS (TYP.)5.5'

(MIN.)

EX. 10" & 6" DIP

WATERMAINS

CONNECT TO EX. 10" & 6"

DIP WATERMAINS (TYP.)

SURFACE ELEV.

SURFACE ELEV.

STA. 1+58.13

STA. 13+02.42

8.

0'

7.

0'

6.

7' 5.

7'

DIA. OF

PIPE (IN.) L (FT.)

QUANTITY

(C.Y.) CLASS

>48 22-28 30-40

IV

IV

III

III

III

III

IV

III

III

MINIMUM RIPRAP REQUIRED

TIE THE LAST 6 JOINTS ON INLET AND OUTLET PIPES

AND BED IN GRANULAR MATERIAL. ANY COVER LESS

THAN 2' OVER TOP OF PIPE SHALL BE GRANULAR

MATERIAL.

SECTION A-A

SECTION B-B

NOTE:

ONE CUBIC YARD IS

APPROXIMATELY 1.4 TONS.

PLAN

1' (8"-27" DIA. PIPE)

1.5' (30" AND LARGER PIPE)

RIPRAP

NONWOVEN GEOTEXTILE

FABRIC

1' (8"-27" DIA. PIPE)

1.5' (30" AND LARGER PIPE)

RIPRAP

NONWOVEN GEOTEXTILE FABRIC

EXTEND 1' UNDER FES

D

IA

D

IA

B

A

BL

2'

2' 4

12 8 5 III

CRUSHED STONE 3/4" TO

NO. 4 PER ASTM D448

GEOFABRIC

SUITABLE

FILL (TYP.)

SUITABLE

FILL (TYP.)

EX.

SOIL

EX.

SOIL

GEOFABRIC

EXISTING SOIL

EXISTING SOIL

SUITABLE

FILL (TYP.)

EX.

SOIL

EX.

SOIL

SUITABLE

FILL (TYP.)

SUITABLE

FILL (TYP.)

EX. SOIL

EX. SOIL

VARIES 6.5' TO

8.0' (SEE SHEETS

C201-S AND C201-N)

GEOFABRIC

GEOFABRIC

CUT GEOFABRIC

AROUND PIPE

PENETRATION

GEOFABRIC

GEOFABRIC

CUT GEOFABRIC

AROUND PIPE

PENETRATION

4" PERFORATED

HDPE DRAIN TILE (TYP.)

4" PERFORATED

HDPE DRAIN TILE (TYP.)

BJN

12"CLAY CAP

RESTORED SURFACE (TOPSOIL OR PAVEMENT)

VARIES

1:1 M

AX1:1 MAX

1:1 M

AX

1:1 MAX

1 REVISION 1 02/07/2025

12"CLAY CAP

RESTORED SURFACE (TOPSOIL OR PAVEMENT)

12"CLAY CAP

RESTORED SURFACE (TOPSOIL OR PAVEMENT)

CRUSHED STONE 3/4" TO

NO. 4 PER ASTM D448

CRUSHED STONE 3/4" TO

NO. 4 PER ASTM D448

24"

MIN.

AutoCAD SHX Text

GARY R. JOHNSON 18238

Sheets and Views
DETAILS 2

File details come from the government source that posted it. Updated .