This is a specification section (10 51 26) for plastic lockers and benches as part of a building renovation project (RENOVATE BLDG 204 CATH LAB II, Project #621-22-121).

The specification establishes requirements for the procurement and installation of solid plastic lockers and matching benches. The basis-of-design manufacturer is Bradley Corporation (Menomonee Falls, WI), with the specified product being the Bradley LENOX LOCKER (two-tier configuration, 72 inches nominal height, 12 inches width, 18 inches depth) and Bradley LENOX PHENOLIC PEDESTAL BENCH (60 inches long, 9.5 inches wide). Lockers shall be fabricated from High Density Polyethylene (HDPE) with a minimum of 30 percent recycled content, featuring 3/8-inch thick sides, tops, bottoms, dividers, and shelves, and 1/2-inch thick doors. Doors must include continuous stainless steel piano hinges (Type 304), ADA/ABA-compliant handles, and ventilation slots. Hardware specifications include No. 10-24 sex bolts for locker connectors and stainless steel tamper-resistant fasteners. Material requirements also include 3/8-inch HDPE mortised shelves, slope tops, and a 1-inch solid HDPE base with 4-inch height.

Quality assurance requirements mandate that manufacturers possess a minimum of five years' experience in plastic locker manufacturing and submit product data, component samples, and documentation of successful installations. Installers must have minimum three years' experience. Surface-burning characteristics per ASTM E 84 must achieve a Flame-Spread Index of 100 or less and Smoke-Developed Index of 450 or less. Products must be certified under GREENGUARD Indoor Air Quality Certification or comparable programs acceptable to the Veterans Administration. A 20-year manufacturer warranty against rust, delamination, and breakage of plastic parts under normal use is required. Delivery shall occur only after building enclosure and HVAC activation, with units shipped fully assembled and stored upright, protected from direct sunlight. Installation requires lockers to be level, plumb, and secured at top and bottom to walls, with multiple units connected using manufacturer-supplied sex bolts and installed per approved shop drawings.

View the file

Other files

File Type Posted
00 01 10 - Table Of Contents 29072026.pdf PDF
07 42 13 - Insulated Metal Wall Panels.pdf PDF
Appendix B - HVAC CUTSHEETS.pdf PDF
07.112_AE112.2 - PHASE TWO ENLARGED PLAN.pdf PDF
36C24926R0057 0004.pdf PDF
09 54 00 - Operating Room Modular Diffuser System.pdf PDF
23 82 00 - Convection Heating and Cooling Units.pdf PDF
14.38_E600 - PARTIAL SINGLE LINE DIAGRAM.pdf PDF
14.20_EE102.2.2 - PHASE 2 ENLARGED TECH FIRE ALARM PLAN.pdf PDF
14.13_ED102.5.2 - PHASE 5 DEMOLITION TECH FIRE ALARM PLAN.pdf PDF
14.11_ED102.4.2 - PHASE 4 DEMOLITION TECH FIRE ALARM PLAN.pdf PDF
07.704_AF702.4 - PHASE FOUR FINISH PLANS.pdf PDF
13.10_MH102.4 - MECHANICAL SECOND FLOOR HVAC PLAN - PHASE 4.pdf PDF
S-102824-291.pdf PDF
01 45 35a - Schedule of SI.pdf PDF
28 05 00 - Common Work Results for Electronic Safety and Security.pdf PDF
07 41 13 - Insulated Metal Roof Panels.pdf PDF
14.26_EE102.5.2 - PHASE 5 ENLARGED TECH FIRE ALARM PLAN.pdf PDF
14.08_ED102.3.2 - PHASE 3 DEMOLITION TECH FIRE ALARM PLAN.pdf PDF
13.12_MH103 - MECHANICAL ROOF HVAC PLAN.pdf PDF
07.730_AQ732 - OVERALL EQUIPMENT PLAN.pdf PDF
FINAL COORDINATION STUDY -- 12-17-19.pdf PDF
28 23 00 - Video Surveillance.pdf PDF
01 45 35 - Special Inspections.pdf PDF
00 01 10 - Table Of Contents.pdf PDF
00 00 00 - Specification Cover.pdf PDF
14.27_EE102.5.3 - PHASE 5 ENLARGED LIGHTING TECH PLAN.pdf PDF
14.16_EE102.1.2 - PHASE 1 ENLARGED TECH FIRE ALARM PLAN.pdf PDF
14.24_EE102.4.2 - PHASE 4 ENLARGED TECH FIRE ALARM PLAN.pdf PDF
14.22_EE102.3.2 - PHASE 3 ENLARGED TECH FIRE ALARM PLAN.pdf PDF
11.10_PD102.5 - PLUMBING SECOND FLOOR DEMOLITION PLAN PHASE 5.pdf PDF
2026-0724 Addendum 02 Summary.docx DOCX document
09 05 16 - Subsurface Preparation For Floor Finishes.pdf PDF
01 45 35b - Statement of SI.pdf PDF
14.29_E501 - TECHNOLOGY DETAILS.pdf PDF
14.06_ED102.2.2 - PHASE 2 DEMOLITION TECH FIRE ALARM PLAN.pdf PDF
36C24926R0057 0002.pdf PDF
621-22-121 Site Visit Sign in sheet.pdf PDF
2026-0629 Cath Lab II - BID specs - Add 01.pdf PDF
36C24926R0057 0001.pdf PDF
2026-0629 Cath Lab II - BID Dwgs - Add 01.pdf PDF
621-22-121 Renovate B204 for Cath Lab II - Bid Specifications.pdf PDF
36C24926R0057_1.pdf PDF
General Conditions Breakout.xlsx XLSX spreadsheet
Price Breakout Schedule.xlsx XLSX spreadsheet
Contractor EMR Certification Form.docx DOCX document
Calculation of Contractor Self Performed Work.xlsx XLSX spreadsheet
WD TN20260191 2 Jan 2026.pdf PDF
Past_Performance_Questionnaire.docx DOCX document
621-22-121 Renovate B204 for Cath Lab II - Bid Drawings.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RENOVATE BLDG 204 CATH LAB II

Project #621-22-121

10 51 26

PLASTIC LOCKERS

SECTION 10 51 26

PLASTIC LOCKERS AND BENCH

PART 1 - GENERAL

1.1 DESCRIPTION

A. SUMMARY: This section includes Solid Plastic Lockers and Bench.

1.2 RELATED WORK

A. Section 06 10 00 ROUGH CARPENTRY: For locker anchorage.

B. Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS

1.3 APPLICABLE PUBLICATIONS

A. ASTM International (ASTM):

1. ASTM A 666 - Standard Specification for Annealed or Cold-Worked

Austenitic Stainless-Steel Sheet, Strip, Plate, and Flat Bar.

2. ASTM E 84 - Standard Test Method for Surface Burning

Characteristics of Building Materials.

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

1. Include overall locker dimensions, floor plan, elevations, sections, details, and attachments to other work. Include choice of options with details.

2. Manufacturer's data sheets for each type of product indicated include fabrication details, description of materials and finishes.

3. Product Test Reports: When requested by Architect, provide documentation indicating compliance of products with requirements, from a qualified independent testing agency.

B. Samples for Selection: Furnish samples of manufacturer's full range of colors for initial selection.

C. Samples for Approval: Furnish a physical sample of the material in the selected color.

1. Size: 6 by 6 inch (102 by 102 mm) in type of finish specified.

D. Warranty: Sample of special warranty.

E. Operation and Maintenance Data.

F. Installation instructions.

G. Sustainable Design Submittals, as described below:

1. Volatile organic compounds per volume as specified in PART 2 -

PRODUCTS.

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications: Minimum [5] years’ experience in the manufacture of plastic lockers. Manufacturers seeking approval must submit the following in accordance with Instructions to Bidders and

Division 01 requirements:

1. Product data, including test data from qualified independent testing agency indicating compliance with requirements.

2. Samples of each component of product specified.

3. List of successful installations of similar products available for evaluation by Architect.

4. Submit substitution request not less than 15 days prior to bid date.

B. Installers Qualifications: An experienced Installer regularly engaged in the installation of lockers for a minimum of 3 years.

C. Source Limitations: Obtain plastic lockers and trim accessories from single manufacturer.

D. Accessibility Requirements: Comply with requirements of ADA/ABA.

E. Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84 by a qualified testing agency.

Identify products with appropriate markings of applicable testing agency.

1. Flame-Spread Index: 100 or less.

2. Smoke-Developed Index: 450 or less.

F. Indoor Environmental Quality Certification: Provide certificate indicated that products have been certified under the following programs, or a comparable certification acceptable to Veterans

Administration.

1. GREENGUARD Indoor Air Quality Certified.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Do not deliver plastic lockers and bench to the site until the building is enclosed and HVAC systems are in operation. Deliver plastic lockers and bench in manufacturer's original packaging. Store in an upright condition. Protect plastic lockers and bench from exposure to direct sunlight.

B. Ship plastic lockers fully assembled.

C. Lift and handle plastic lockers from the base not the sides.

1.7 WARRANTY

A. Special Manufacturer’s Warranty: 20 years against rust, delamination, or breakage of plastic parts under normal use.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Basis-of-Design Manufacturer: Subject to compliance with requirements, provide products of Bradley Corporation, Menomonee

Falls, WI 53051, (800)272-3539, fax (262)251-5817; Email info@BradleyCorp.com; Website www.bradleycorp.com.

1. Provide basis of design products or comparable products.

B. MATERIALS

1. High Density Polyethylene (HDPE): 30 percent pre-consumer recycled content polyethylene thermoplastic formed under high pressure into solid plastic components.

2. High Density Polyethylene (HDPE): 100 percent pre-consumer or post-consumer recycled content polyethylene thermoplastic formed under high pressure into solid plastic components.

3. Stainless-Steel Sheet: ASTM A 666, Type 304.

4. Fasteners: Tamper-Resistant Fasteners: Stainless steel torx-head screws.

a. Locker Connectors: No. 10-24 sex bolts.

b. Anchors: Type and size required for secure anchorage.

c. Drilled-in-place Masonry Anchors: Minimum 1/4 by 1-3/4-inch

(6 by 44 mm) screws.

2.2 STANDARD PLASTIC LOCKERS

A. Basis-of-Design Product: Bradley LENOX LOCKER.

B. Locker Configuration: Two tier

C. Locker Dimensions

1. Height, Nominal: 72 inches (1829 mm).

2. Width: 12 inches (305 mm).

3. Depth: 18 inches (457 mm).

D. Material: HDPE plastic, 30 percent minimum recycled material.

E. Sides, Tops, Bottoms, Dividers, and Shelves: 3/8 inch (10 mm) thick

HDPE plastic with smooth finish.

F. Locker Shelves: 3/8-inch (10 mm) HDPE plastic, mortised into sides and back.

G. Locker Tops: Slope top.

H. Doors: Fabricate from a single piece 1/2-inch (13 mm) HDPE plastic.

mailto:info@BradleyCorp.com http://www.bradleycorp.com/

1. Doors and Frame: 1/2 inch (13 mm) thick HDPE plastic with matte texture finish with ventilation slots.

2. Handle: ADA/ABA Compliant handle fabricated from injection molded plastic.

3. Locks: Standard hasp.

4. Hinges: Continuous piano hinges, .05 inch/18 gauge (1.27 mm) thick type 304 stainless steel fabricated to wrap around edges of door and frame and attached with stainless steel tamper-resistant screws.

a. Finish: Powder coated to match color of locker.

5. Latch Bar: Full-height latch bar constructed of 1/2-inch (13 mm)

HDPE plastic secured to locker with stainless steel tamper-resistant screws.

I. Color: As selected by Architect from manufacturer's full range.

J. Accessories:

1. Coat Hooks: Black polycarbonate double hook.

2. End Panels: 1/2 inch (13mm) thick, with color and finish matching locker body.

3. Filler Panels: 1/2-inch (13 mm) HDPE filler panel, with color and finish matching locker body, attached with 3/8 inch (10 mm) thick HDPE solid plastic angle bracket.

4. Wall Hooks: Black powder coated, cast zinc hook two per locker.

5. Number Plate: White acrylic with black film coating, laser etched with number specified. Provide one per locker.

6. Locker Base: 1 inch (26 mm) solid HDPE plastic, with black or finish matching locker body, 4 inch (101 mm) high.

7. Coat Rod: Schedule 40 PVC with plastic pole sockets and stainless-steel tamper-resistant screws.

2.3 STANDARD BENCH

A. Basis-of-Design Product: Bradley LENOX PHENOLIC PEDESTAL BENCH

B. Bench Dimensions

1. Length 60” Long Bench

2. Width 0095 9 ½” Bench

C. Color: As selected by Architect from manufacturer's full range.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install lockers and bench in climate-controlled environment, shielded from direct sunlight.

B. General: Install on floor or other firm support. Install level, plumb, and true.

1. Position locker base per approved shop drawing. Using fasteners provided by manufacturer, anchor base sections to the floor.

2. Attach filler pieces to lockers with male-female sex bolts.

3. Position first locker according to submittal layout. Square and plumb the locker using concealed shims. Secure the locker to the wall at the top and bottom of the locker. Position second locker next to first, square and plumb to align the tops and bottoms;

and temporarily clamp lockers together. Drill four holes through the sides of the lockers and connect lockers using sex bolts provided by manufacturer.

4. Install bench per manufactures instructions.

C. Accessories: Fit exposed connections of trim, fillers, and closures together to form tight, hairline joints, with concealed fasteners and splice plates furnished by locker manufacturer. Install as indicated on approved shop drawings.

1. Coat Hooks: Attach with at least two fasteners.

2. Identification Plates: Identify plastic lockers with approved identification numbers. Attach plates to each locker door.

3. Filler Panels: Attach with concealed fasteners.

4. Sloping Tops: Attach sloping-tops to plastic lockers, with closures at exposed ends.

5. Finished End Panels: Attach at ends indicated.

3.2 CLEANING

A. Clean locker interior and exterior surfaces.

B. Remove packaging and construction debris and legally dispose of off-site.

- - - E N D - - -