07.112_AE112.2 - PHASE TWO ENLARGED PLAN.pdf
PDF 907 KB Posted
- Solicitation number
- 36C24926R0057
About this file
This document is an architectural drawing set for Phase Two of a medical center renovation project, specifically detailing enlarged floor plan and reflected ceiling plan (RCP) views for a facility located in Mt. Home, Tennessee operated by the U.S. Department of Veterans Affairs.
The scope of work includes construction of multiple examination rooms (Exam Four through Exam Eight, designated L204D through L204H) with standardized 9-foot ceiling heights, partition installation with fire-rating requirements (1-hour and 2-hour fire barriers), and coordination of structural, mechanical, electrical, and plumbing systems. Key construction requirements include installation of Type F1 column furring, fire-treated plywood blocking (3/4-inch minimum) for all wall-mounted items such as casework, equipment, fixtures, and handrails, with blocking extending 12 inches beyond each mounting point and additional steel reinforcement for items exceeding 250 pounds of force. The ceiling design specifies 2-foot-by-2-foot acoustical tile with integrated LED light fixtures, sprinkler head coordination, and scribing for tight fit. General requirements address demolition damage repair, door opening clearances of 4 inches from partition faces, alignment with existing construction, and fully recessed fire extinguisher cabinets with fire-resistant blocking. All work must conform to referenced general notes on sheet GI000, seismic restraint requirements on AE501, and overall ceiling plan coordination on AE112, with the fully sprinklered facility requiring 100-percent bid documentation.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
AP
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
N N
AN
S
S
AP
AN
S
F
S
AP
AN
S
GENERAL FLOOR PLAN NOTES
A.
B.
C.
D.
E.
F.
G.
H.
REFER TO GI000 FOR GENERAL NOTES.
COLUMN FURRING ARE TYPE F1, UNLESS OTHERWISE NOTED.
PATCH AND REPAIR DAMAGES FROM DEMOLITION IN ALL AFFECTED AREAS.
CONSTRUCT ALL DOOR OPENINGS 4 ” CLEAR FROM A PERPENDICULAR PARTITION OUTSIDE FACE OF FRAME, UNLESS NOTED
OTHERWISE.
PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, CONFIRM ALIGNMENT WITH PLANS.
ANCHOR WALL HUNG CASEWORK, GRAB BARS AND EQUIPMENT ATTACHED TO WALLS TO BLOCKING BETWEEN STUDS.
PROVIDE CONTINUOUS BLOCKING AT TOP AND BOTTOM OF EQUIPMENT.
ALIGN NEW CONSTRUCTION WITH EXISTING ADJACENT CONSTRUCTION WHERE APPLICABLE. PREPARE ALIGNED SURFACES TO
RECEIVE NEW FINISHES.
STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING (SME& P) SYMBOLS ARE SHOWN FOR COORDINATION PURPOSES
ONLY - REFER TO RESPECTIVE DISCIPLINE.
NEW WORK LEGEND
EXISTING CONSTRUCTION
EXISTING SMOKE ZONE BARRIER
EXISTING 2-HOUR FIRE BARRIER
EXISTING 1-HOUR FIRE BARRIER
PROPOSED PARTITION
PROPOSED SMOKE ZONE BARRIER
PROPOSED 1-HOUR FIRE BARRIER
PROPOSED 2-HOUR FIRE BARRIER
PROPOSED DOOR AND FRAME
NOT PART OF CURRENT
PHASE
NO ARCHITECTURAL SCOPE
ON THIS SHEET
FOR ALL WALL-MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO CASEWORK, EQUIPMENT, FIXTURES, HANDRAILS, ETC., PROVIDE CONTINUOUS 3/4" FIRE-TREATED PLYWOOD BETWEEN STUDS AND SECURED TO STUD WALL STRUCTURE. ALL BLOCKING TO EXTEND 12" MINIMUM IN ALL DIRECTIONS BEYOND EACH MOUNTING POINT. CONTRACTOR TO REVIEW ALL DRAWINGS AND SPECIFICATIONS TO DETERMINE THE LOCATIONS OF ALL SPECIFIC MOUNTING LOCATIONS. FOR ALL ITEMS THAT EXCEED 250 LBS. OF FORCE AT ANY POINT IN ANY
DIRECTION, PROVIDE ADDITIONAL STEEL AT ALL BLOCKING LOCATIONS.
1.31.7
2.3
RR
PP
NN
MM
LL
JJ
CC
DD
EE
FF
GG
HH
2.62.73.9
129 SF
EKG ONE
L203A
125 SF
EKG TWO
L203B
128 SF
EXAM TWO
L204B
126 SF
EXAM ONE
L204A
565 SF
WAITING
L202
168 SF
EXAM THREE
L204C
EXAM SEVEN
L204G
EXAM EIGHT
L204H
565 SF
CORRIDOR
C2-3
110 SF
VITALS
C2-3A
CORRIDOR
C2-1
ELEVATOR
S-18
ELEVATOR
S-17
MECH
'-4
'-4
'-4
'-1 3/
4"
'-1 1 3
/8"
10'-5 3/4" +/-
9"
F1
B1
A1
A1
A1
A1
A1
A1
A1
A1
A1
6'-1 3/8" 13'-7 7/8"
A1
A1
'-8
A2
'-2
6'-9" 6'-0 1/8" 6'-0 1/8" 6'-0 1/8"
A2
B1
B1
B1
A1
11.01
09.01
09.01
L202B
L2
C
L2
A L2
B
L2
C L2
D
L2
E L2
F
L2
A L2
B
132 SF
EXAM FOUR
L204D
139 SF
EXAM FIVE
L204E
150 SF
EXAM SIX
L204F
565 SF
CORRIDOR
C2-3
EXAM SEVEN
L204G
EXAM EIGHT
L204H
CORRIDOR
C2-1
MECH
MECH
STAFF TOILET
L219
STAFF TOILET
L217
MECH
PATIENT TOILET
L205
F1F1
F1
F1
F1
AE411
2 SIM
AE411
2 SIM
AE411
2 SIM
AE411
2 SIM
AE411
2 SIM
AE411
2 SIM
AE502
AE411
AE411
3 SIM
A1
146 SF
RECEPTION
L202A
20 1/2"
20 1/2"
20 1/2"
6'- 7"
1'- 0"
AE502
L2
A
09.0109.01
1'- 1"
R2 3
1.31.7
2.3
RR
PP
NN
MM
LL
JJ
CC
DD
EE
FF
GG
HH
2.62.73.9
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
8' - 8"
7' - 0"
EKG ONE
L203A
WAITING
L202
ELEVATOR
S-18
ELEVATOR
S-17
CORRIDOR
C2-1
MECH
EKG TWO
L203B EXAM TWO
L204B
EXAM ONE
L204A
EXAM THREE
L204C
EXAM FOUR
L204D
EXAM FIVE
L204E
EXAM SIX
L204F
EXAM SEVEN
L204G
EXAM EIGHT
L204H
CORRIDOR
C2-3
VITALS
C2-3A
ELEVATOR
S-18
ELEVATOR
S-17
MECH
STAFF TOILET
L219
STAFF TOILET
L217
MECH
PATIENT TOILET
L205
8' - 8" 8' - 8"
AE502
8' - 8"
RECEPTION
L202A
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
REFER TO GI000 FOR GENERAL NOTES.
REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION.
REFER TO LEGEND ON GI001 FOR ADDITIONAL CEILING SYMBOLS.
REFER TO AE112 OVERALL CEILING PLAN FOR COMPLETE CEILING SCOPE.
REFER TO AE501 FOR SEISMIC RESTRAINT FOR ACT REQUIREMENTS.
PROVIDE COLD-FORMED STEEL FRAMED BULKHEADS WITH GYPSUM BOARD SHEATHING AT CEILING HEIGHT TRANSITIONS.
PAINT AS SPECIFIED IN ROOM FINISH SCHEDULE.
REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
ALL LAY-IN CEILING GRID SHALL BE EQUAL FROM OPPOSING EDGES OF ROOM UNLESS OTHERWISE NOTED. AVOID CUT SIZES
SMALLER THAN 3"
CENTER SPRINKLER HEADS WITHIN CEILING TILES. COORDINATE WITH OTHER CEILING MOUNTED ACCESSORIES.
CEILING HEIGHT IS 9'-0" UNLESS NOTED OTHERWISE.
GENERAL RCP NOTES
CEILING LEGEND
2'-0" x 2'-0" ACOUSTICAL TILE CEILING
GYPSUM BOARD CEILING
2'-0" x 2'-0" SUPPLY AIR DIFFUSER
1'-0" x 1'-0" RETURN AIR GRILLE
6" CAN LIGHT
OCCUPANCY SENSOR
2'-0" x 2'-0" LED LIGHT FIXTURE
OS
EXIT SIGN
REFER TO GI001
FOR ADDITIONAL SYMBOLS
DEMOLISH 2'-0" x 2'-0" ACOUSTICAL
CEILING TILE IN FUTURE PHASE G PROVIDE GASKETED GRID ON
SPECIFIED CEILING
DRAWING NOTES
09.01 FEATHER IN NEW GYPSUM WALL BOARD TO EXISTING, ALIGN SURFACES.
11.01 FULLY RECESSED FIRE EXTINGUISHER. PROVIDE FIRE RESISTANT BLOCKING AND ADDITIONAL FRAMING AS REQUIRED FOR
INSTALLATION. REFER TO FIRE EXTINGUISHER CABINET DETAIL ON SHEET AE112.1.
KEY PLAN
ENTIRE FLOOR
AREA SHOWN ON SHEET
NORTH EXISTING BELOW
CEILING ONLY RELATED WORK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Date:Revisions:No.
F
Au to de sk
D oc s:
//M t H om e
VA
C at h
La b/
FF
E_
R en ov at e C at h
La b
II_
B2
(2
4)
.rv t
7/
/2
1:
:4
PM
AE112.2
PHASE TWO ENLARGED PLAN
06/12/2026 MP NM
RENOVATE BLDG 204 CATH LAB II 621-22-121
MT. HOME, TENNESSEE
100% BID DOCUMENTS
MT HOME, VA
MEDICAL
CENTER Approved: MT HOME, VA MEDICAL CENTER
3/16" = 1'-0"1 ENLARGED PLAN - PHASE TWO
3/16" = 1'-0"2 ENLARGED REFLECTED CEILING PLAN - PHASE TWO
0 100% BID DOCUMENTS 06/12/2026
1 ADDENDUM 01 06/29/2026
3 ADDENDUM 03 07/29/2026
File details come from the government source that posted it. Updated .