This document summarizes a federal solicitation for construction services to alter an F-35 aircraft hangar. The solicitation will result in a single firm fixed-price contract to demolish 19,913 square feet of hangar shop space and reconfigure the area for F-35 aircraft maintenance at Dane County Regional Airport - Truax Field in Madison, Wisconsin. Work includes modifications to 19,803 square feet of hangar space for aircraft make-up power and air systems, and upgrades to mechanical, plumbing, electrical, and security systems. A pre-bid conference will be held on February 16, 2021 with bids due by March 8, 2021. The contract duration is 365 days with a magnitude between $10-25 million. The North American Industry Classification code is 236220 and options are included for additional work. Brand name products will be required and a Small Business Subcontracting Plan from large businesses. The solicitation and plans are available at beta.SAM.gov.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 Alter Hangar 406, newest first.
File Type Posted
Abstract of Offers with Hubzone Preference.pdf PDF
SF1419 Abstract of Offers - No Hubzone Preference.pdf PDF
W50S9F21B00010007.pdf PDF
W50S9F21B00010006.pdf PDF
406 Questions and Answers_142-143.pdf PDF
23 07 00_Add04.pdf PDF
406 Questions and Answers_113-141.pdf PDF
F-102_Add03.pdf PDF
T-001 Add03.pdf PDF
E-101_Add03.pdf PDF
32 13 14.13_Add03.pdf PDF
21 13 18.00 10_Add03.pdf PDF
F-001_Add03.pdf PDF
W50S9F21B00010004.pdf PDF
C-141_Add02.pdf PDF
G-011_Add02.pdf PDF
AD101_Add02.pdf PDF
C-101_Add02.pdf PDF
E-501_Add02.pdf PDF
SD111_Add02.pdf PDF
A-201_Add02.pdf PDF
10 28 13_Add02.pdf PDF
A-311_Add02.pdf PDF
406 Questions and Answers_26-112.pdf PDF
G-001_Add02.pdf PDF
E-101_Add02.pdf PDF
01 50 00_Add02.pdf PDF
12 21 00_Add02.pdf PDF
10 14 00.20_Add02.pdf PDF
05 40 00_Add02.pdf PDF
01 78 00_Add02.pdf PDF
Asbestos and Lead Inspection.pdf PDF
Repair Roofs 406 Warranty Cert.pdf PDF
A-401_Add02.pdf PDF
W50S9F21B00010003.pdf PDF
10 22 39_Add01.R1.pdf PDF
A-131_Add01.R1.pdf PDF
C-121_Add01.R1.pdf PDF
W50S9F21B00010002.pdf PDF
B.07.406 Site Visit Sign In 22Feb21.pdf PDF
B.07.406 Site Visit Sign In 19Feb21.pdf PDF
Pre-Bid Slides - F-35 406.pptx PPTX presentation
W50S9F21B00010001.pdf PDF
W50S9F-21-B-0001.pdf PDF
ATTACHMENT 6-Justification and Approval Monaco.pdf PDF
ATTACHMENT 8-406 Submittal Log.xlsx XLSX spreadsheet
ATTACHMENT 9-SFS Form 12.xls XLS spreadsheet
ATTACHMENT 10-PRE-BID CONFERENCE AND SITE VISIT INSTRUCTIONS.pdf PDF
ATTACHMENT 1-Truax F-35 B406 XGFG182008 Specs Vol 1 of 2 Dated 31 July 2020.pdf PDF
ATTACHMENT 5-Justification and Approval Andover.pdf PDF
Show all 50

F-35 Alter Hangar 406 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXTERIOR INSULATION AND

FINISHING SYSTEM (EIFS)

WALL AS SCHEDULED

CONTINUOUS SEALANT

AND BACKER ROD

(BOTH SIDES)

DOOR FRAME (GROUT SOLID)

DOOR (SEE SCHEDULE)

D O

O R

O P

E N

IN

G

CONTINUOUS 1/4"

DRIP EDGE

CONTINUOUS SEALANT

AND BACKER ROD

3"

CONTINUOUS SEALANT

AND BACKER ROD

(BOTH SIDES)

JAMB ANCHORS, PER

MANUFACTURER REQUIREMENTS

EXTERIOR INSULATION AND

FINISHING SYSTEM (EIFS)

DOOR FRAME (GROUT SOLID)

DOOR (SEE SCHEDULE)

DOOR OPENING

1/4"

CONTINUOUS SEALANT

AND BACKER ROD

(BOTH SIDES)

EXTERIOR INSULATION AND

FINISHING SYSTEM (EIFS)

ALUMINUM WINDOW

GROUT ADJACENT

CORE SOLID

(SEE STRUCTURAL)

SHIM AS REQUIRED

SOLID SURFACE SILL,

SSM-2 TYPICAL

CONTINUOUS SEALANT

AND BACKER ROD

(BOTH SIDES)

EXTERIOR INSULATION AND

FINISHING SYSTEM (EIFS)

ALUMINUM WINDOW

SHIM AS REQUIRED

METAL FLASHING W/ 1/4" DRIP

EDGE AT WINDOW HEAD

ALUMINUM WINDOW

EXISTING EXTERIOR

INSULATION AND FINISHING

SYSTEM (EIFS)

EXISTING WALL

EXISTING LINTEL

CONTINUOUS SEALANT

AND BACKER ROD

(BOTH SIDES)

SHIM AS REQUIRED

3" 4 1/2"

METAL FLASHING AT WINDOW HEAD

ALUMINUM WINDOW

EXISTING EXTERIOR

INSULATION AND FINISHING

SYSTEM (EIFS)

EXISTING WALL

STEEL LINTEL, SEE STRUCTURAL

CONTINUOUS SEALANT AND

BACKER ROD (BOTH SIDES)

3" 4 1/2"

METAL FLASHING

AT WINDOW SILL. SLOPE AWAY

FROM WINDOW. PROVIDE

1/4" METAL DRIP EDGE

ALUMINUM WINDOW

EXISTING EXTERIOR

INSULATION AND FINISHING

SYSTEM (EIFS)

WALL AS SCHEDULED

CONTINUOUS SEALANT AND

BACKER ROD (BOTH SIDES)

EXTERIOR INSULATION AND

FINISHING SYSTEM (EIFS),

MATCH EXISTING

SHIM AS REQUIRED

SOLID SURFACE SILL,

SSM-2 TYPICAL

SEALANT AND BACKER ROD

T.O. PC SILL

104'-0"

ALUMINUM

WINDOW SYSTEM

3" 4 1/2"

BACKER ROD AND

SEALANT, TYP.

PRE-FINISHED METAL SILL

FLASHING WITH HEMMED

EDGE, SET IN SEALANT SOLID SURFACE

SILL, SSM-2

TYPICAL

SEALANT AND

BACKER ROD

EXISTING CMU.

CAST STONE SILL

SILL ANCHORS AND

FASTENERS BY CAST

STONE SUPPLIER

1/2"

CONT. SEALANT

SHIM AS

REQUIRED

CONTINUOUS RIGID

INSULATION

VAPOR BARRIER

SUPPORT ANGLE

GALVANIZED

SCREWS

INDUSTRIAL ADHESIVE

FIELD VERIFY SILL DIMENSIONS

1" NOMINAL MASONRY

VENEER OVER MORTAR

BED OVER SCRATCH

COAT OVER METAL LATH

OVER CONTINUOUS

INSULATION

OVERHEAD COILING DOOR

METAL HOOD ENCLOSURE

EXTERIOR INSULATION AND

FINISHING SYSTEM (EIFS)

3/16" STEEL PLATE (PAINTED)

(SEE STRUCTURAL)

INSULATED COILING DOOR

(SEE SCHEDULE)

WEATHERSEAL

CONTINUOUS 1/4" DRIP

EDGE

T.O. OPENING

AS SCHEDULED

WALL AS SCHEDULED

CONTINUOUS SEALANT

AND BACKER ROD

PREFINISHED METAL

DRIP FLASHING WITH

HEMMED EDGE SET IN

SEALANT

PRECAST SILL BLOCK

EXISTING CMU

3" EIFS WALL SYSTEM

(INSTALLED PER

MANUFACTURER'S

RECOMMENDATIONS)

T.O. PC SILL

104'-0"

1" 1 3/8"

3"

CONTINUOUS RIGID

INSULATION

VAPOR BARRIER

SUPPORT ANGLE,

COORDINATE WITH

STRUCTURAL

SEALANT WITH BACKER

ROD AND WEEP TUBES

EVERY 24"

DRAINAGE STRIP

SET IN ADHESIVE

TROWELED ADHESIVE

TO PROMOTE

DRAINAGE

SELF-ADHERED

MEMBRANE FLASHING

INDUSTRIAL ADHESIVE

3 3/8"

7/8"

GALVANIZED SCREWS

1" NOMINAL MASONRY

VENEER OVER MORTAR

BED OVER SCRATCH

COAT OVER METAL LATH

OVER CONTINUOUS

INSULATION

FIRST FLOOR

100'-0"

1" NOMINAL MASONRY

VENEER OVER MORTAR

BED OVER SCRATCH

COAT OVER METAL LATH

OVER CONTINUOUS

INSULATION EXISTING CMU

CONCRETE

FOUNDATION, SEE

STRUCTURAL

CONCRETE SLAB

ON GRADE,

SEE STRUCTURAL

METAL BOTTOM TRACK

OR BACK WRAP EIFS AT

BOTTOM EDGE

1/2" ISOLATION JOINT

WITH SEALANT

2" THICK RIGID

FOUNDATION AND

UNDER SLAB

INSULATION. UNDER

SLAB INSULATION

MINIMUM 4' WIDE.

VAPOR BARRIER

PROVIDE 4" AT GRADE

AND 2" AT PAVEMENT

SLOPE GRADE AWAY

FROM FOUNDATION

WALL

WATER

RESISTANT BASE

COAT

EIFS FINISH

SEALANT WITH BOND

BREAKER

METAL DRIP EDGE

EXISTING CMU

3" EIFS WALL SYSTEM

(INSTALLED PER

MANUFACTURER'S

RECOMMENDATIONS)

CONTINUOUS RIGID

INSULATION

VAPOR BARRIER

1 5/8" METAL STUD

FURRING

5/8" GYPSUM

1" NOMINAL MASONRY

VENEER OVER MORTAR

BED OVER SCRATCH

COAT OVER METAL LATH

OVER CONTINUOUS

INSULATION

EXISTING CMU

CONTINUOUS RIGID

INSULATION

VAPOR BARRIER

3 5/8" METAL STUD

FURRING

5/8" GYPSUM

1" NOMINAL MASONRY

VENEER OVER MORTAR

BED OVER SCRATCH

COAT OVER METAL LATH

OVER CONTINUOUS

INSULATION

EXISTING CMU

3 5/8" METAL STUD

FURRING

5/8" GYPSUM

EXISTING CMU

3 5/8" METAL STUD

FURRING

5/8" GYPSUM

/8

V E

R

IF

Y I N

F

IE

L D

/8

/8

3 5/8"

VERIFY IN FIELD

1'-3 1/4" 4 3/8"

EXISTING STEEL

COLUMN

EXISTING CMU

3 5/8" METAL STUD

FURRING

5/8" GYPSUM

3 5/8"

VERIFY IN FIELD

2'-0" 3 5/8"

/8

V E

R

IF

Y I N

F

IE

L D

/8

EXISTING STEEL COLUMN

1 1/2" METAL

WALL PANEL

FASTENED TO

EXISTING

SUPPORTS

EXISTING

STRUCTURE

EXISTING 1"

INSULATION

EXISTING METAL

PANEL

SUPPORTS

EXISTING 3" IMP

PREFINISHED METAL

DRIP FLASHING WITH

HEMMED EDGE SET IN

SEALANT

NEW FASCIA PANEL,

MATCH ADJACENT

CANOPY PANELS

FOR HEIGHT AND

COLOR

DOOR BRUSH SEAL

1 1/2" METAL

WALL PANEL

3" RIGID INSULATION

EXISTING

STRUCTURE

EXISTING 1"

INSULATION

EXISTING

HANGAR DOOR

NEW SUPPORT

STRUCTURE, SEE

STRUCTURAL

DRAWINGS

EXISTING 3"

IMP

METAL LINER PANEL

INSULATED COILING DOOR

(SEE SCHEDULE)

COILING DOOR JAMB

AND MOUNT

WALL AS SCHEDULED

THERMAL BREAK

EXTERIOR INSULATION AND

FINISHING SYSTEM (EIFS)

3/16" STEEL PLATE (PAINTED)

(SEE STRUCTURAL)

CONTINUOUS SEALANT

CMU WALL AS

SCHEDULED

1" GYPSUM LINER PANEL

2 LAYERS 5/8" TYPE "X" RATED

GYPSUM WITH STAGGERED

JOINTS

C-H STUD 24" O.C. MAX

J RUNNER

CEILING AS SCHEDULED

2-HR HORIZONTAL RATED ASSEMBLY

ALL JOINTS FINISHED

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

/3

/2

:1

:4

P M

C R e v it L o c a l\

-1

.0

-A

-C e n tr a l-p jc

.r v t

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

F -3

A L T

E R

B U

IL

D

IN

G

A-501

DETAILS

XGFG182008ANG NO.:

3141300-190289.01

BAE

JJB

July 31, 2020

PJC

1 1/2" = 1'-0"8

EXTERIOR DOOR HEAD

1 1/2" = 1'-0"9

EXTERIOR DOOR JAMB

1 1/2" = 1'-0"6

WINDOW JAMB

1 1/2" = 1'-0"11

WINDOW HEAD AT EXISTING JAMB

1 1/2" = 1'-0"10

WINDOW HEAD AT EXISTING LINTEL

1 1/2" = 1'-0"5

WINDOW HEAD

1 1/2" = 1'-0"7

WINDOW SILL

1 1/2" = 1'-0"12

EXT WINDOW SILL

1 1/2" = 1'-0"17

EXTERIOR COILING DOOR HEAD

1 1/2" = 1'-0"13

EIFS TO STONE TRANSITION

1 1/2" = 1'-0"14

BASE OF WALL

1" = 1'-0"1

ENLARGED PLAN DETAIL

1" = 1'-0"2

ENLARGED PLAN DETAIL

1" = 1'-0"4

ENLARGED PLAN DETAIL

1" = 1'-0"3

ENLARGED PLAN DETAIL

1 1/2" = 1'-0"15

METAL PANEL REPLACEMENT

1 1/2" = 1'-0"16

METAL PANEL AT DOOR OPENING

1 1/2" = 1'-0"18

EXTERIOR COILING DOOR JAMB

07/31/20 TYPE B3 FINAL

2 03/03/21 ADDENDUM - 02

1 1/2" = 1'-0"19

FIRE RATED CEILING

Sheets
A-501 - DETAILS

File details come from the government source that posted it. Updated .