This solicitation is seeking bids for construction services to alter an F-35 aircraft hangar at Dane County Regional Airport - Truax Field in Madison, Wisconsin. Key details include demolishing approximately 19,913 square feet of existing hangar shop space and modifying another 19,803 square feet of hangar space to accommodate F-35 aircraft. Work will include mechanical, plumbing and electrical systems installation; communications, security, and technology cabling; and fire suppression system modifications. Two optional items are also included. The bid due date is March 8, 2021. Award will be made to the responsive and responsible lowest bidder. Interested contractors should attend the pre-bid conference on February 16, 2021 and register on SAM.gov to access solicitation documents through beta.SAM.gov. The North American Industry Classification code is 236220 and contract performance period is 365 days.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 Alter Hangar 406 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BET
PB
PP
COM
FO
TGB
TSE
A
S
M
N
C
E
ACS
ACP
IDS
PS
SP
S
V
S
S
TECHNOLOGY SYMBOLS
TELEPHONE SERVICE ENTRANCE PROTECTION DEVICE
BUILDING ENTRANCE TERMINAL
COMMUNICATIONS PUNCH BLOCK
COMMUNICATIONS PATCH PANEL
COMMUNICATIONS CABINET
WALL-MOUNTED FIBER OPTIC CABINET
TELECOMMUNICATIONS GROUNDING BUS BAR
2-POST EQUIPMENT RACK
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUS BAR
CABLETRAY
J JUNCTION BOX
CARDREADER
SECURITY SYSTEM SYMBOLS
REX
CARDREADER-PINPAD
KEY PAD
MOTION DETECTOR
STATUS SENSOR / MONITOR
AUDIBLE ALARM
ELECTRIC STRIKE
ACCESS CONTROL SYSTEM
ACCESS CONTROL PANEL
REQUEST TO EXIT
KP
INTRUSION DETECTION SYSTEM
1. THE INFORMATION SHOWN IS BASED ON EXISTING DRAWINGS AND SITE
OBSERVATIONS TO ASSIST THE CONTRACTOR IN BIDDING. THE CONTRACTOR
SHOULD VISIT THE SITE TO VERIFY EXISTING CONDITIONS. THE TECHNOLOGY
SYSTEMS DRAWINGS INDICATE EXISTING TECHNOLOGY SYSTEMS ITEMS TO
BE REMOVED. THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OF
WORK REQUIRED AND DO NOT INDICATE EVERY DEVICE, BOX, CONDUIT,
WIRE OR CABLE THAT MUST BE REMOVED.
2. DASHED WALLS ON THE FLOOR PLANS INDICATE EXISTING WALLS BEING
DEMOLISHED. REFER TO THE ARCHITECTURAL DEMOLITION PLANS FOR THE
EXACT EXTENT OF WORK REQUIRED BY THIS PROJECT. REMOVE ALL
DEVICES ON DASHED WALLS NOT SHOWN ON THE CONTRACT DRAWINGS.
REFER TO DEMOLITION DRAWINGS OF OTHER TRADES. WHERE CONTROL
PANELS AND APPURTENANCES THAT HAVE TECHNOLOGY SYSTEMS
CONNECTIONS ARE BEING REMOVED, INCLUDE DISCONNECTION AND
REMOVAL OF ALL ASSOCIATED CONDUIT, WIRING AND CABLING.
3. TECHNOLOGY SYSTEMS ITEMS (E.G. TECHNOLOGY OUTLETS, SECURITY
SYSTEMS DEVICES, AUDIO DEVICES) THAT ARE REMOVED AND NOT
RELOCATED SHALL REMAIN THE PROPERTY OF THE OWNER. DISPOSE OF
MATERIAL THE OWNER DOES NOT WANT TO REUSE OR RETAIN FOR
MAINTENANCE PURPOSES.
4. OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF POWER TO
TECHNOLOGY SYSTEMS EQUIPMENT OR DEVICES. COORDINATE ALL
OUTAGES WITH THE OWNER. CONDUIT CONCEALED IN WALL CONSTRUCTION
MAY BE ABANDONED IN PLACE IF NOT AFFECTED BY OTHER CONSTRUCTION.
5. PROVIDE A BLANK COVERPLATE FOR ALL BOXES IN EXISTING MASONRY
WALLS THAT ARE TO REMAIN IN PLACE. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS ASSOCIATED WITH TYPE AND ATTACHMENT.
6. REMOVE ALL CONDUIT WHERE WALLS ARE BEING REMOVED. WHERE
CONDUIT IS IN THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE OR
CABLE AND PLUG. WHERE CONDUIT IS RUN EXPOSED, ALL ASSOCIATED
CLAMPS, SUPPORTS, HANGERS, ETC. SHALL ALSO BE REMOVED.
7. COORDINATE ALL WORK WITH OTHER CONTRACTORS AT THE JOB SITE
BEFORE REMOVING EXISTING TECHNOLOGY SYSTEMS ITEMS AND
INSTALLING NEW ITEMS.
8. EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE.
RELOCATED EXISTING CONDUIT SHALL NOT BE ALLOWED.
DEMOLITION GENERAL NOTES
GENERAL NOTES
1. PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT REQUIRED TO INSTALL
COMPLETE TECHNOLOGY SYSTEMS AS INDICATED ON THESE DRAWINGS
AND AS SPECIFIED.
2. MOUNT ALL TECHNOLOGY OUTLETS AT HEIGHTS ABOVE FINISHED FLOOR AS
SHOWN IN THE TECHNOLOGY OUTLET SCHEDULE U.N.O.
3. SEE ELECTRICAL SPECIFICATIONS FOR LOCATIONS WHERE GRS CONDUIT
SHALL BE USED, OR WHERE IMC, EMT, OR PVC CONDUIT MAY BE USED.
4. OFFSET BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS A
MINIMUM OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE-RATED
WALLS SHALL BE OFFSET A MINIMUM OF 24" HORIZONTALLY. 'THRU-THE-
WALL' BOXES SHALL NOT BE ALLOWED WITHOUT THE WRITTEN APPROVAL
OF THE ARCHITECT/ENGINEER.
5. VERIFY ALL EQUIPMENT SIZES AND POWER REQUIREMENTS FOR EQUIPMENT
SUPPLIED BY OTHERS PRIOR TO INSTALLATION OF CONDUIT.
6. MOUNT TECHNOLOGY SYSTEMS EQUIPMENT/DEVICES SO AS TO ALLOW
ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF
TECHNOLOGY SYSTEMS EQUIPMENT/DEVICES ON EQUIPMENT SUPPLIED BY
ANOTHER CONTRACTOR SHALL BE COORDINATED WITH AND APPROVED BY
THAT CONTRACTOR IN ADVANCE OF INSTALLATION.
7. CONCEAL ALL ELECTRICAL CONDUITS AND JUNCTION BOXES. COORDINATE
WITH THE OTHER TRADES AND USE CHASES AND CEILING SPACES
PROVIDED. WHERE BOXES AND CONDUIT ARE NOTED TO BE INSTALLED
EXPOSED, THEY SHALL BE PAINTED TO MATCH THE SURFACE.
8. PROVIDE ALL OPENINGS REQUIRED IN WALLS. REPAIR ALL OPENINGS TO
MATCH EXISTING USING A QUALIFIED CONTRACTOR AT THE EXPENSE OF
THIS CONTRACTOR. GROUT OR SEAL ALL CONDUITS THROUGH WALLS INTO
OPENINGS. FIRESTOP ALL PENETRATIONS THROUGH FLOORS AND FIRE-
RATED WALLS IN A MANNER THAT MAINTAINS THE RATING OF THE FLOOR OR
WALL PENETRATED.
9. TERMINATE ALL TELEPHONE AND DATA JACKS WITH ALL 4 PAIRS TO ALLOW
FOR INTERCHANGEABILITY.
10. INSTALL ALL TELEPHONE AND DATA CABLES IN CONDUIT OR CABLE TRAY.
11. PROVIDE PLASTIC OR NYLON BUSHINGS IN ALL CONDUIT STUBS PRIOR TO
THE INSTALLATION OF CABLES.
LINE TYPE KEY
EXISTING TO BE REMOVED BY THIS
CONTRACTOR (DARK DASHED LINE)
EXISTING TO REMAIN WORK
(THIN SOLID LINE)
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDER FLOOR BY
THIS CONTRACTOR
AUDIO VISUAL SYMBOLS
LOUDSPEAKER (HORN TYPE)
CEILING-MOUNTED SPEAKER
WALL-MOUNTED SPEAKER
VOLUME CONTROL
SOUND AND PAGING CABINET
PAGING STATION
VIDEO SURVEILLANCE SYMBOLS
F
F
F
F
MOUNTING MODIFIERS:
WALL MOUNT
F APPROXIMATE VIEWING DIRECTION
CAMERA TYPE:
C: DETENTION CORNER
F: FIXED
M: MULTISENSOR
O: FISHEYE
P: PAN-TILT-ZOOM
V: VARIFOCAL
XX
HORIZONTAL VIEWING ANGLE
CAMERA ID
POLE MOUNT
EXTERIOR CORNER MOUNT
DETENTION CORNER MOUNT
VIDEO SURVEILLANCE CAMERA:
CEILING MOUNTF
GENERAL SYMBOLS
9.xxx
T-40X
T-40X
DETAIL NUMBER / SHEET NUMBERx/T-xxx
A
T-40X 1
KEYED NOTE, USED TO DESCRIBE ADDITIONAL
INFORMATION OF WORK REQUIRED, SPECIFIC TO
THE SHEET AND/OR DEAIL IT IS SHOWN WITH
IT ROOM
116 ROOM NAME AND NUMBER
DOOR IDENTIFICATION
BUILDING SECTION
ENLARGED PLAN
INTERIOR ELEVATION
TECHNOLOGY OUTLET SCHEDULE NOTES:
1. REFER TO DIVISION 26 SPECIFICATIONS FOR BOX AND CONDUIT SPECIFICATIONS AND EXECUTION REQUIREMENTS.
SINGLE-PORT TECHNOLOGY OUTLET FOR WALL-MOUNTED PHONE:
- (1) 1" CONDUIT
- (1) 4" SQUARE x 1-1/2" DEEP BACKBOX WITH SINGLE GANG VERTICAL TRIM RING
- (1) STAINLESS STEEL FACEPLATE WITH CATEGORY 6 JACK AND PHONE LUGS
- (1) CATEGORY 6 CABLE
45" AFF TO CENTER
OF BOX U.N.O.
TECHNOLOGY OUTLET SCHEDULE
SYMBOL MOUNTINGDESCRIPTION COMMENTS
TWO-PORT TECHNOLOGY OUTLET:
- (1) 1" CONDUIT
- (1) 4-11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- (1) SINGLE-GANG, TWO-PORT FACEPLATE
- (2) CATEGORY 6 JACKS
- (2) CATEGORY 6 CABLES
18" AFF TO CENTER
OF BOX U.N.O.
FOUR-PORT TECHNOLOGY OUTLET:
- (1) 1" CONDUIT
- (1) 4-11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- (1) SINGLE-GANG, FOUR-PORT FACEPLATE
- (4) CATEGORY 6 JACKS
- (4) CATEGORY 6 CABLES
18" AFF TO CENTER
OF BOX U.N.O.
HDMI TECHNOLOGY OUTLET:
- (1) 1 1/4" CONDUIT
- (2) 4-11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- (2) SINGLE-GANG, HDMI FACEPLATE COUPLER.
HD
TWO-PORT CEILING-MOUNTED TECHNOLOGY OUTLET:
- (1) 1" CONDUIT
- (1) 4-11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- (1) SINGLE-GANG, TWO-PORT FACEPLATE
- (2) CATEGORY 6 JACKS
- (2) CATEGORY 6 CABLES
FLUSH WITH LAY-IN
CEILING
OWNER TO
PROVIDE HDMI
CABLE BETWEEN
FACEPLATES.
FIBER OPTIC TECHNOLOGY OUTLET:
- (1) 1 1/4" CONDUIT
- (2) 4-11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- (6) SINGLE-MODE FIBER OPTIC STRANDS
- (3) SM LC DUPLEX COUPLER
SEE SHEET T-501
FOR OUTLET
LAYOUT.
FO
W
TELEVISION TELECOMMUNICATIONS OUTLET:
- (1) 1" CONDUIT STUB
- (1) 4-11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- (1) SINGLE-GANG, TWO-PORT FACEPLATE
- (1) CATEGORY 6 JACK
- (1) CATEGORY 6 CABLE
- (1) F-F BULKHEAD CONNECTOR COUPLER
- (1) RG-6 CABLE
TV
12" ABOVE
HORIZONTAL
CENTERLINE OF
TELEVISION UNO.
- OUTLET
CONFIGURATION
ASSUMES TV SET-
TOP BOX IS
LOCATED AT
DISPLAY.
TECHNOLOGY SCOPE BID MATRIX
ITEM
FLOOR BOX ROUGH-IN, INCLUDING FLOOR BOXES AND CONDUITS
CABLE TRAY, INCLUDING ALL REQUIRED SUPPORT HARDWARE AND FITTINGS
EQUIPMENT ROOM FITTINGS (PER DIV 27 SPECIFICATIONS)
EQUIPMENT ROOM POWER RECEPTACLES
GROUNDING OF CABLE TRAY AND EQUIPMENT ROOM COMPONENTS
BACKBONE CABLING, TERMINATION COMPONENTS (e.g. WALL-FIELDS), TERMINATION, TESTING AND LABELING
TECHNOLOGY SYSTEMS ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS, CONDUIT AND SLEEVES
UNDERGROUND CONDUITS IN/OUT OF BUILDING, INCLUDING ASSOCIATED HANDHOLES
PATCH PANELS
TELECOMMUNICATIONS OUTLET (TO) FACEPLATES AND JACKS
HORIZONTAL CABLING, TERMINATIONS, TESTING AND LABELING
GROUND BARS (TMGB, TGB) AND ELECTRICAL SERVICE BONDING
FLOOR BOX AND TELECOMMUNICATION OUTLET (TO) ASSOCIATED POWER RECEPTACLES
SHOWN ON CLIN
T-SERIES
EQUIPMENT ROOM PLYWOOD WALL COVERINGS
ROOF PENETRATION CONDUITS
INFORMATION DISPLAY SYSTEM AND TV OUTLETS, MOUNTS, DISPLAYS AND CABLING
PA SYSTEM ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
PA SYSTEM COMPONENTS (HEAD-END, MICROPHONES, SPEAKERS/HORNS, VOLUME CONTROLS) AND CABLING
INFORMATION DISPLAY SYSTEM AND TV ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
ACS FIELD DEVICES (e.g. CARD READERS, STATUS SENSORS, REX) AND CABLING
SECURITY SYSTEMS (ACS, VSS) ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
ACS DOOR HARDWARE INCLUDING ELECTRIC STRIKES, MAGNETIC LOCKS AND ASSOCIATED POWER SUPPLIES
VSS HEAD-END, CAMERAS, MOUNTS AND CABLING
E AND T-SERIES
T-SERIES
T-SERIES
T-SERIES
E-SERIES (PWR)
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
E-SERIES (PWR)
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES
CONTRACT LINE ITEM NUMBER:
CLIN 0001 = BASE BID
CLIN 0002 = COMMUNICATIONS CABLING AND EQUIPMENT
CLIN 0003 = SECURITY CABLING AND EQUIPMENT
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
/8
/2
:0
:1
P M
C R e v it L o c a l\
-1
.0
-E
-C e n tr a l-ry a n .k e n n y A
C
L
.r v t
T R
U A
X F
IE
L D
A N
G B
M A
D
IS
O N
W
I
F -3
A L T
E R
B U
IL
D
IN
G
T-001
NOTES, SYMBOLS &
ABBREVIATIONS
XGFG182008ANG NO.:
3141300-190289.01
RKK
JRM
July 31, 2020
MJR
TECHSYS ABBREVIATIONS
& AND
3R NEMA 3R RATED
4X NEMA 4X RATED
@ AT
A/E ARCHITECT / ENGINEER
ACS ACCESS CONTROL SYSTEM
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISH GRADE
ALT ALTERNATE
ANT ANTENNA
AP (WIRELESS) ACCESS POINT
AV AUDIO VISUAL
BET BUILDING ENTRANCE TERMINAL
BID BAGGAGE INFORMATION DISPLAY
BLDG BUILDING
C CONDUIT
CAB CABINET
CATV COMMUNITY ANTENNA TELEVISION
CL CENTERLINE
CLG CEILING
CLIN CONTRACT LINE ITEM NUMBER
COAX COAXIAL
COMM COMMUNICATIONS
DO DOOR OPERATOR
DSS DIGITAL SATELLITE SERVICE
DWG DRAWING
EC ELECTRICAL CONTRACTOR
EMT ELECTRICAL METALLIC TUBING
ETR EXISTING TO REMAIN
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FID FLIGHT INFORMATION DISPLAY
FO FIBER OPTIC
FPD FLAT-PANEL DISPLAY
GC GENERAL CONTRACTOR
GID GATE INFORMATION DISPLAY
GND GROUND
GRC GALVANIZED RIGID CONDUIT
GRS GALVANIZED RIGID STEEL
HH HAND HOLE
HPC HIGH PAIR COUNT
HVAC HEATING, VENTILATION, AIR CONDITIONING
IDF INTERMEDIATE DISTRIBUTION FRAME
IDS INTRUSION DETECTION SYSTEM
IMC INTERMEDIATE METALLIC CONDUIT
IT INFORMATION TECHNOLOGY
ITS INFORMATION TRANSPORT SYSTEMS
JB JUNCTION BOX
MAX MAXIMUM
MDF MAIN DISTRIBUTION FRAME
MH MAN HOLE
MIN MINIMUM
MMFO MULTIMODE FIBER OPTIC
MNS MASS NOTIFICATION SYSTEM
MON MONITOR
MTD MOUNTED
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NTWK NETWORK (DATA)
OC ON CENTER
PA PUBLIC ADDRESS
PROJ PROJECTOR
PTZ PAN - TILT - ZOOM
PVC POLYVINYL CHLORIDE
RCV RECEIVER
REQ'D REQUIRED
SCHED SCHEDULE
SE SERVICE ENTRANCE
SMFO SINGLEMODE FIBER OPTIC
SS STAINLESS STEEL
SYS SYSTEM
TBR TO BE REMOVED
TC TECHNOLOGY CONTRACTOR
TGB TELECOMMUNICATIONS GROUNDING BUSBAR
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TO TELECOMMUNICATIONS OUTLET
TSE TELEPHONE SERVICE EQUIPMENT
TV TELEVISION
TYP TYPICAL
UF UNDER FLOOR
UG UNDERGOUND
UNO UNLESS NOTED OTHERWISE
UTP UNSHIELDED TWISTED PAIR
VSS VIDEO SURVEILLANCE SYSTEM
WL WET LOCATION LISTED
WP WEATHERPROOF
WS WORKSTATION
07/31/20 TYPE B3 FINAL
3 03/08/21 ADDENDUM - 03
| Sheets |
| T-001 - NOTES, SYMBOLS & ABBREVIATIONS |
File details come from the government source that posted it. Updated .