406 Questions and Answers_142-143.pdf

PDF 89 KB Posted

Attached to
F-35 Alter Hangar 406
Solicitation number
W50S9F-21-B-0001
Issued by

About this file

This document contains details regarding a federal solicitation for alteration services to an F-35 aircraft hangar. The solicitation seeks fixed-price bids to demolish approximately 20,000 square feet of hangar space and reconfigure it for F-35 aircraft maintenance at Dane County Regional Airport in Madison, Wisconsin. Scope of work includes mechanical, plumbing, electrical, and communications systems installation. Two option items relate to a fire protection runoff storage trench and infill slab. Brand name justification is required for several security and control systems. The pre-bid conference is scheduled for February 16, 2021 with bids due by March 8, 2021. The contract is for one year with a total estimated value between $10-25 million. The solicitation will be posted on beta.SAM.gov and amendments issued through this site. Interested parties must register in the System for Award Management to be eligible to bid.

View the file

Other files

File Type Posted
SF1419 Abstract of Offers - No Hubzone Preference.pdf PDF
Abstract of Offers with Hubzone Preference.pdf PDF
W50S9F21B00010007.pdf PDF
W50S9F21B00010006.pdf PDF
23 07 00_Add04.pdf PDF
406 Questions and Answers_113-141.pdf PDF
22 31 00_Add03.pdf PDF
F-102_Add03.pdf PDF
T-121 Add03.pdf PDF
E-101_Add03.pdf PDF
32 13 14.13_Add03.pdf PDF
F-001_Add03.pdf PDF
C-101_Add03.pdf PDF
01 50 00_Add03.pdf PDF
Specs TOC_Add03.pdf PDF
C-102_Add03.pdf PDF
21 13 18.00 10_Add03.pdf PDF
T-001 Add03.pdf PDF
W50S9F21B00010005.pdf PDF
01 45 00.00 10_Add03.pdf PDF
C-504_Add03.pdf PDF
34 71 13.19_Add03.pdf PDF
C-121_Add03.pdf PDF
AD101_Add02.pdf PDF
A-311_Add02.pdf PDF
G-001_Add02.pdf PDF
12 21 00_Add02.pdf PDF
C-101_Add02.pdf PDF
10 14 00.20_Add02.pdf PDF
G-011_Add02.pdf PDF
A-301_Add02.pdf PDF
A-801_Add02.pdf PDF
406 Questions and Answers_26-112.pdf PDF
01 78 00_Add02.pdf PDF
01 50 00_Add02.pdf PDF
A-901_Add02.pdf PDF
A-201_Add02.pdf PDF
C-141_Add02.pdf PDF
Specs TOC_ Add02.pdf PDF
01 45 00.00 10_Add02.pdf PDF
10 28 13_Add02.pdf PDF
W50S9F21B00010004.pdf PDF
SD111_Add02.pdf PDF
E-501_Add02.pdf PDF
E-101_Add02.pdf PDF
A-101_Add02.pdf PDF
05 40 00_Add02.pdf PDF
02 83 00_Add02.pdf PDF
01 14 00_Add02.pdf PDF
01 11 00_Add02.pdf PDF
Show 40 more

Latest 50 of 86 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers (142-143) Date: March 12, 2021

Solicitation Number W50S9F-21-B-0001 F-35 Hangar 406, Madison, Wisconsin

142. Question: The mechanical insulation pages of the specification book (230700/220719) do not match with the insulation schedule tables on drawing pages M-603 and M-612. Can we get clarification of which specification to use?

Answer: Section 23 07 00 has been updated in Amendment 0005 to align with the schedules on the drawings.

143. Question: It is shown in the plans that a fence is placed on the ramp outside the hangar. Typically, on a project like this, Low Profile Airport Barricades are placed 10 feet outside the fence line for additional visibility and delineation. This is not shown on the plans even though the fence extends into the AOA. Based on the plans, there should be 485 linear feet of barricades but is not shown.

Should this be added or is it not required?

Answer: Low profile barriers are not required in front of the temporary project boundary fence line around the hangar.