SD111_Add02.pdf

PDF 278 KB Posted

Attached to
F-35 Alter Hangar 406 Federal contract opportunity
Solicitation number
W50S9F-21-B-0001
Issued by
Department of the Army National Guard

About this file

This document summarizes a federal contract opportunity notice for construction services to alter an F-35 aircraft hangar at Dane County Regional Airport - Truax Field in Madison, Wisconsin. The project involves demolishing approximately 19,913 square feet of existing hangar shop space and reconfiguring the area for F-35 aircraft maintenance operations, including new lavatories, office space, break rooms, and repair shops. An additional 19,803 square feet of existing hangar space will be modified to accommodate F-35 aircraft and incorporate modifications such as a high expansion foam fire suppression system, aircraft make-up power and air systems, and lightning protection. The contract value is estimated between $10-25 million. A pre-bid conference will be held on February 16, 2021 with bids due by March 8, 2021. The contract duration is 365 days from notice to proceed. The solicitation will utilize brand name justification and preferences for HubZone small businesses.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 Alter Hangar 406, newest first.
File Type Posted
Abstract of Offers with Hubzone Preference.pdf PDF
SF1419 Abstract of Offers - No Hubzone Preference.pdf PDF
W50S9F21B00010007.pdf PDF
W50S9F21B00010006.pdf PDF
406 Questions and Answers_142-143.pdf PDF
23 07 00_Add04.pdf PDF
406 Questions and Answers_113-141.pdf PDF
F-102_Add03.pdf PDF
T-001 Add03.pdf PDF
E-101_Add03.pdf PDF
32 13 14.13_Add03.pdf PDF
21 13 18.00 10_Add03.pdf PDF
F-001_Add03.pdf PDF
W50S9F21B00010004.pdf PDF
C-141_Add02.pdf PDF
G-011_Add02.pdf PDF
AD101_Add02.pdf PDF
C-101_Add02.pdf PDF
E-501_Add02.pdf PDF
A-201_Add02.pdf PDF
10 28 13_Add02.pdf PDF
A-311_Add02.pdf PDF
406 Questions and Answers_26-112.pdf PDF
G-001_Add02.pdf PDF
E-101_Add02.pdf PDF
01 50 00_Add02.pdf PDF
12 21 00_Add02.pdf PDF
10 14 00.20_Add02.pdf PDF
05 40 00_Add02.pdf PDF
01 78 00_Add02.pdf PDF
Asbestos and Lead Inspection.pdf PDF
Repair Roofs 406 Warranty Cert.pdf PDF
A-401_Add02.pdf PDF
04 20 00_Add02.pdf PDF
W50S9F21B00010003.pdf PDF
10 22 39_Add01.R1.pdf PDF
A-131_Add01.R1.pdf PDF
C-121_Add01.R1.pdf PDF
W50S9F21B00010002.pdf PDF
B.07.406 Site Visit Sign In 22Feb21.pdf PDF
B.07.406 Site Visit Sign In 19Feb21.pdf PDF
Pre-Bid Slides - F-35 406.pptx PPTX presentation
W50S9F21B00010001.pdf PDF
W50S9F-21-B-0001.pdf PDF
ATTACHMENT 6-Justification and Approval Monaco.pdf PDF
ATTACHMENT 8-406 Submittal Log.xlsx XLSX spreadsheet
ATTACHMENT 9-SFS Form 12.xls XLS spreadsheet
ATTACHMENT 10-PRE-BID CONFERENCE AND SITE VISIT INSTRUCTIONS.pdf PDF
ATTACHMENT 1-Truax F-35 B406 XGFG182008 Specs Vol 1 of 2 Dated 31 July 2020.pdf PDF
ATTACHMENT 5-Justification and Approval Andover.pdf PDF
Show all 50

F-35 Alter Hangar 406 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R0 R2 R4 R6 R8 10 L8 L6 L4 L2 L0

A A

B B

C C

D D

E E

F F

G G

/2

/2

161'-0"

12'-7" 16'-0" 16'-0" 16'-0" 16'-0" 16'-6" 16'-6" 16'-0" 16'-0" 16'-0" 16'-0" 12'-7"

3.901 3.901

3.901

Ex. TSL

100'-0"

Ex. TSL

100'-0"

Ex. TSL

100'-0"

Ex. TSL

100'-0"

3.002

3.001

Ex. TSL

100'-0"

3.001

3.001

3.002

3.001

3.002

Ex. TSL

100'-0"

3.001

Ex. TSL

100'-0"

Ex. TSL

100'-0"

3.001

3.001

Ex. TSL

100'-0"

3.001

3.001

3.002

3.001

3.001

.0

3.001

3.003

3.003 3.003 3.003 3.003 3.003

Ex. TSL

100'-0"

3.004 3.004

.0

.0

3.106

3.106

3.106

3.106

3.106

3.106

CRITICAL SUPERSTRUCTURE COMPONENTS

ARE EMBEDDED IN THE EXISTING FLOOR.

NO CUTTING OF EXISTING HANGAR FLOOR

IS ALLOWED UNLESS COMPONENT IS

SHOWN ON THIS PLAN.

GR GR GR GR

GRGR

GR GR

3.209 3.209 3.209 3.209

3.209 3.209

3.209 3.209

2 2 2 2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

/2

/2

:1

:1

P M

C R e v it L o c a l\

-1

.0

-S -C e n tr a l-

D e v ik a .D e M a ri o n

.r v t

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

F -3

A L T

E R

B U

IL

D

IN

G

SD111

FLATWORK

DEMOLITION PLAN

XGFG182008ANG NO.:

3141300-190289.01

MJE

DXC

July 31, 2020

JJF

KEYED NOTES

3.001 EXISTING 5" SLAB TO REMAIN

3.002 DEMO EXISTING 5" SLAB

3.003 DEMO EXISTING CONCRETE RAMP AND 5" SLAB BELOW.

3.004 DEMO EXISTING EQUIPMENT PAD AND SLAB ON GROUND BELOW.

3.106 EXISTING ARCH TRUSS TIE PLATE BELOW SLAB IS A CRITICAL

SUPERSTRUCTURE COMPONENT AND EMBEDDED IN THE EXISTING

FLOOR. TAKE CARE TO AVOID.

3.209 NEW GROUND RECEPTACLE IN EXISTING SLAB PER ELECTRICAL

DRAWINGS. TAKE CARE IN AVOIDANCE OF EXISTING TIE PLATE

BETWEEN TRUSS ARCH FRAMES.

3.901 BID OPTION 2: DEMO EXISTING CONCRETE TRENCH PANELS AND

EXPOSE ABANDONED UTILITY TRENCH. INFILL EXISTING TRENCH

WITH 6" CONCRETE SLAB OVER GRANULAR FILL. SEE DETAIL

11/S-511.

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"1

FLATWORK DEMOLITION PLAN

07/31/20 TYPE B3 FINAL

2 03/03/21 ADDENDUM - 02

Sheets
SD111 - FLATWORK DEMOLITION PLAN

File details come from the government source that posted it. Updated .