G-011_Add02.pdf

PDF 414 KB Posted

Attached to
F-35 Alter Hangar 406 Federal contract opportunity
Solicitation number
W50S9F-21-B-0001
Issued by
Department of the Army National Guard

About this file

This document provides details for an invitation for bid to award a single firm fixed-price construction contract. The solicitation seeks services to alter an F-35 aircraft hangar at Dane County Regional Airport - Truax Field in Madison, Wisconsin. Key work includes demolishing 19,913 square feet of hangar space and reconfiguring it for F-35 maintenance operations. An additional 19,803 square feet of hangar space will be modified to accommodate F-35 aircraft, including high expansion foam fire suppression system modifications, aircraft make-up power and air systems, and lightning protection. The solicitation will also include two options related to fire protection runoff storage and perimeter trench infill. Interested contractors must attend a pre-bid conference on February 16, 2021 and site visit. The bid submission deadline is March 8, 2021. Award will be made to the responsive and responsible lowest bidder. The contract duration is 365 days from notice to proceed.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 Alter Hangar 406, newest first.
File Type Posted
Abstract of Offers with Hubzone Preference.pdf PDF
SF1419 Abstract of Offers - No Hubzone Preference.pdf PDF
W50S9F21B00010007.pdf PDF
W50S9F21B00010006.pdf PDF
406 Questions and Answers_142-143.pdf PDF
23 07 00_Add04.pdf PDF
406 Questions and Answers_113-141.pdf PDF
F-102_Add03.pdf PDF
T-001 Add03.pdf PDF
E-101_Add03.pdf PDF
32 13 14.13_Add03.pdf PDF
21 13 18.00 10_Add03.pdf PDF
F-001_Add03.pdf PDF
W50S9F21B00010004.pdf PDF
C-141_Add02.pdf PDF
AD101_Add02.pdf PDF
C-101_Add02.pdf PDF
E-501_Add02.pdf PDF
SD111_Add02.pdf PDF
A-201_Add02.pdf PDF
10 28 13_Add02.pdf PDF
A-311_Add02.pdf PDF
406 Questions and Answers_26-112.pdf PDF
G-001_Add02.pdf PDF
E-101_Add02.pdf PDF
01 50 00_Add02.pdf PDF
12 21 00_Add02.pdf PDF
10 14 00.20_Add02.pdf PDF
05 40 00_Add02.pdf PDF
01 78 00_Add02.pdf PDF
Asbestos and Lead Inspection.pdf PDF
Repair Roofs 406 Warranty Cert.pdf PDF
A-401_Add02.pdf PDF
04 20 00_Add02.pdf PDF
W50S9F21B00010003.pdf PDF
10 22 39_Add01.R1.pdf PDF
A-131_Add01.R1.pdf PDF
C-121_Add01.R1.pdf PDF
W50S9F21B00010002.pdf PDF
B.07.406 Site Visit Sign In 22Feb21.pdf PDF
B.07.406 Site Visit Sign In 19Feb21.pdf PDF
Pre-Bid Slides - F-35 406.pptx PPTX presentation
W50S9F21B00010001.pdf PDF
W50S9F-21-B-0001.pdf PDF
ATTACHMENT 6-Justification and Approval Monaco.pdf PDF
ATTACHMENT 8-406 Submittal Log.xlsx XLSX spreadsheet
ATTACHMENT 9-SFS Form 12.xls XLS spreadsheet
ATTACHMENT 10-PRE-BID CONFERENCE AND SITE VISIT INSTRUCTIONS.pdf PDF
ATTACHMENT 1-Truax F-35 B406 XGFG182008 Specs Vol 1 of 2 Dated 31 July 2020.pdf PDF
ATTACHMENT 5-Justification and Approval Andover.pdf PDF
Show all 50

F-35 Alter Hangar 406 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B406

B404

OPERATIONS

DO NOT CROSS RED LINE

ROOM 126

EXISTING

TRANSFORMER

B400

B401

B409

T4

B305

CONSTRUCTION BOUNDARY / PERIMETER FENCE

BASE BOUNDARY LINE

B420

0.101

0.102

0.103

0.104

12.0'

0.105

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ANG NO:

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

SHEET NO.

© Copyright 2020

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

Mead & Hunt, Inc.

07/31/20 TYPE B3 FINAL

M A

D I S

O N

W

I

T R

U A

X

F

I E

L D

A

N G

B

F

A

L T

E R

B

U I L

D I N

G

NOT FOR CONSTRUCTION

JULY 31, 2020

XGFG182008

2 03/03/21 ADDENDUM - 02

00 30 60

G-011

PROJECT WORKSITE

AND OPERATION PLAN

JJB

CAJ

JJB

RESTRICTED AREAS/SAFETY AREAS:

1. RUNWAYS, TAXIWAYS, AND APRON: CONSTRUCTION ACTIVITY ADJACENT TO THE RUNWAYS,

TAXIWAYS, AND APRONS WHICH WILL BE IN USE SHALL BE COORDINATED WITH AIRPORT

OPERATIONS THROUGH THE COR. CONSTRUCTION ACTIVITY WILL BE AUTHORIZED AFTER

NOTAMS (NOTICES TO AIRMEN) HAVE BEEN ISSUED BY THE AIRPORT (DCRA); AND AFTER IT HAS

BEEN DETERMINED THAT THE HEIGHT OF EQUIPMENT AND MATERIALS IS BEYOND THE REACH OF

THE AIRCRAFT OR SAFELY BELOW ANY PART OF THE AIRCRAFT USING THE OPERATIONS AREAS

WHICH MIGHT OVERHANG THESE AREAS. INFORMATION FOR RUNWAY APPROACHES AND OTHER

AREAS WILL BE SUPPLIED BY THE C.O.R. IF IT IS REQUIRED.

2. EXCEPT AS PROVIDED ON THE CONTRACT PLANS OR IN CONTRACT SPECIAL PROVISIONS OR AS

MAY BE AUTHORIZED BY THE C.O.R. IN WRITING, THE CONTRACTOR SHALL PERFORM

CONSTRUCTION ACTIVITIES WITHIN 80 FEET OF THE EDGE OF AN ACTIVE TAXIWAY OR APRON, WITHIN 250 FEET OF AN ACTIVE RUNWAY CENTERLINE, OR WITHIN 1000 FEET OF A RUNWAY END.

WHEN SO AUTHORIZED TO PERFORM CONSTRUCTION ACTIVITIES WITHIN SUCH AREAS, THE

CONTRACTOR SHALL FIRST IMPLEMENT APPROPRIATE MARKING AND LIGHTING PROVISIONS.

3. EXCAVATION AND OPEN TRENCHES LOCATED WITHIN 250 FEET FROM THE CENTERLINE OF AN

ACTIVE RUNWAY SHALL BE ADEQUATELY SIGNED, MARKED AND LIGHTED. EXCAVATIONS AND

OPEN TRENCHES LOCATED ADJACENT TO TAXIWAY AND APRON PAVEMENT SHALL BE

ADEQUATELY SIGNED, MARKED AND LIGHTED.

4. DEBRIS SHALL NOT BE DEPOSITED ON ANY PORTION OF AN OPERATIONAL RUNWAY, TAXIWAY, OR

APRON. SHOULD ANY DEBRIS BE DEPOSITED ACCIDENTALLY, IT SHALL BE REMOVED

IMMEDIATELY.

5. OPEN-FLAME WELDING OR TORCH-CUTTING OPERATIONS ARE PROHIBITED UNLESS ADEQUATE

FIRE AND SAFETY PRECAUTIONS ARE PROVIDED AND HAVE BEEN APPROVED BY THE TRUAX FIRE

DEPT. ALL VEHICLES ARE TO BE PARKED AND SERVICED BEHIND THE CONSTRUCTION

RESTRICTION LINE 750 FEET OR MORE FROM AN ACTIVE RUNWAY CENTERLINE OR 200 FEET FROM

AN ACTIVE TAXIWAY CENTERLINE.

MARKING AND LIGHTING:

1. EXCAVATION/STOCKPILES-EXCAVATION ADJACENT TO PAVED SURFACES MUST BE

APPROPRIATELY MARKED BY BARRICADES.

2. CONTRACTOR SHALL BARRICADE OPEN EXCAVATIONS AS REQUIRED BY THE C.O.R.

FUEL SUPPORT:

1. ANY TYPE OF FUELING SUPPORT FACILITY OR DEVICE USED TO REFUEL CONSTRUCTION

EQUIPMENT IS SUBJECT TO WANG FIRE INSPECTION. LOCAL FIRE CODES AND SAFETY

STANDARDS SHALL BE MET PRIOR TO COMMENCEMENT OF WORK.

SWEEPING/CLEAN-UP:

1. THE CONTRACTOR SHALL HAVE SWEEPING OR VACUUMING CAPABILITIES ON-SITE AT ALL TIMES

IN ORDER TO REMOVE DEBRIS AS IT OCCURS. UPON COMPLETION, THE CONTRACTOR IS

RESPONSIBLE FOR INSURING THAT THE AREA OF CONCERN IS RETURNED TO ITS ORIGINAL

CONDITION.

HAUL ROUTES:

1. HAUL ROUTES AND ACCESS TO THE CONSTRUCTION SITES WILL BE DISCUSSED AT THE PRE-BID

CONFERENCE AND ARE DEPICTED ON G-001.

2. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS ON THE BASE IN A MANNER THAT WILL

MINIMIZE INTERFERENCE WITH THE NORMAL OPERATIONS OF AIRPORT FACILITIES THAT ARE TO

REMAIN OPEN TO AIR TRAFFIC, AND THE CONTRACTOR SHALL IMPLEMENT ALL SPECIFIED AND

OTHER APPROPRIATE MEASURES TO ENSURE THE SAFETY OF ALL USERS OF THE AIRPORT.

3. THE CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS CONTAINED WITHIN THE

SPECIFICATIONS.

4. CONTRACTOR SHALL NOT USE RADIO EQUIPMENT OR CELL PHONES WITHIN 400 FEET OF

AIRCRAFT.

ENFORCEMENT:

1. VIOLATION OF THESE RULES AND REGULATIONS, DEPENDING UPON SEVERITY OF THE VIOLATION, MAY RESULT IN ONE OR MORE OF THE FOLLOWING:

1.1. A VERBAL AND/OR WRITTEN WARNING.

1.2. REVOCATION OF AOA BADGE AND/OR VEHICLE ACCESS PERMIT.

1.3. THE CONTRACT WORK BEING STOPPED UNTIL CORRECTIVE MEASURES ARE TAKEN TO

PRECLUDE A RECURRENCE OF THE VIOLATION.

2. CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS CONTAINED WITHIN THE

SPECIFICATION.

KEYED NOTES:

X.XXX

0.101 CONSTRUCTION ON B404 WILL BE OCCURRING AT SAME TIME AS B406.

COORDINATE PROJECT CONSTRUCTION AT SHARED PROJECT BOUNDARY

WITH BASE AND B404 PROJECT CONTRACTOR.

0.102 MAINTAIN PARKING LOT ENTRANCE FROM ROADWAY.

0.103 MAINTAIN ROADWAY ACCESS TO B420.

0.104 CONTRACTOR MAY UTILIZE SPACE BEYOND PROJECT EXTENT WHEN

ACTIVELY WORKING ON NORTHEAST OF BUILDING EXTERIOR. MAINTAIN A

MINIMUM 12' ROADWAY ACCESS FOR VEHICLES WHICH NEED TO ACCESS THE

AIRFIELD. MAINTAIN ACCESS TO PARKING STALLS FOR B420 OCCUPANTS.

0.105 MAINTAIN EXISTING BOLLARDS UNTIL INSTALLATION OF NEW GATE.

"OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION":

CONFORMS TO AC150/5370-2E

1. CONTRACTOR SHALL REMOVE FENCE AND PATCH PAVEMENT AND LANDSCAPING

DAMAGED FROM TRAILERS AND FENCING DURING PROJECT.

2. CONTRACTOR LAY DOWN AND TRAILER PARKING AREA SHOWN IS DIAGRAMMATIC AND

WILL BE DISCUSSED IN DETAIL WITH THE AWARDED CONTRACTOR DURING

PRE-CONSTRUCTION MEETING.

GENERAL NOTES:

3141300-190289.01

CONTRACTOR LAY DOWN AREA

C

O

N

T

R

A

C

T

O

T

A

I

L

E

P

A

R

K

I

N

G

Sheets and Views
G-011