G-011_Add02.pdf
PDF 414 KB Posted
- Attached to
- F-35 Alter Hangar 406 Federal contract opportunity
- Solicitation number
- W50S9F-21-B-0001
- Issued by
- Department of the Army National Guard
About this file
This document provides details for an invitation for bid to award a single firm fixed-price construction contract. The solicitation seeks services to alter an F-35 aircraft hangar at Dane County Regional Airport - Truax Field in Madison, Wisconsin. Key work includes demolishing 19,913 square feet of hangar space and reconfiguring it for F-35 maintenance operations. An additional 19,803 square feet of hangar space will be modified to accommodate F-35 aircraft, including high expansion foam fire suppression system modifications, aircraft make-up power and air systems, and lightning protection. The solicitation will also include two options related to fire protection runoff storage and perimeter trench infill. Interested contractors must attend a pre-bid conference on February 16, 2021 and site visit. The bid submission deadline is March 8, 2021. Award will be made to the responsive and responsible lowest bidder. The contract duration is 365 days from notice to proceed.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 Alter Hangar 406 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B406
B404
OPERATIONS
DO NOT CROSS RED LINE
ROOM 126
EXISTING
TRANSFORMER
B400
B401
B409
T4
B305
CONSTRUCTION BOUNDARY / PERIMETER FENCE
BASE BOUNDARY LINE
B420
0.101
0.102
0.103
0.104
12.0'
0.105
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ANG NO:
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
© Copyright 2020
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
Mead & Hunt, Inc.
07/31/20 TYPE B3 FINAL
M A
D I S
O N
W
I
T R
U A
X
F
I E
L D
A
N G
B
F
A
L T
E R
B
U I L
D I N
G
NOT FOR CONSTRUCTION
JULY 31, 2020
XGFG182008
2 03/03/21 ADDENDUM - 02
00 30 60
G-011
PROJECT WORKSITE
AND OPERATION PLAN
JJB
CAJ
JJB
RESTRICTED AREAS/SAFETY AREAS:
1. RUNWAYS, TAXIWAYS, AND APRON: CONSTRUCTION ACTIVITY ADJACENT TO THE RUNWAYS,
TAXIWAYS, AND APRONS WHICH WILL BE IN USE SHALL BE COORDINATED WITH AIRPORT
OPERATIONS THROUGH THE COR. CONSTRUCTION ACTIVITY WILL BE AUTHORIZED AFTER
NOTAMS (NOTICES TO AIRMEN) HAVE BEEN ISSUED BY THE AIRPORT (DCRA); AND AFTER IT HAS
BEEN DETERMINED THAT THE HEIGHT OF EQUIPMENT AND MATERIALS IS BEYOND THE REACH OF
THE AIRCRAFT OR SAFELY BELOW ANY PART OF THE AIRCRAFT USING THE OPERATIONS AREAS
WHICH MIGHT OVERHANG THESE AREAS. INFORMATION FOR RUNWAY APPROACHES AND OTHER
AREAS WILL BE SUPPLIED BY THE C.O.R. IF IT IS REQUIRED.
2. EXCEPT AS PROVIDED ON THE CONTRACT PLANS OR IN CONTRACT SPECIAL PROVISIONS OR AS
MAY BE AUTHORIZED BY THE C.O.R. IN WRITING, THE CONTRACTOR SHALL PERFORM
CONSTRUCTION ACTIVITIES WITHIN 80 FEET OF THE EDGE OF AN ACTIVE TAXIWAY OR APRON, WITHIN 250 FEET OF AN ACTIVE RUNWAY CENTERLINE, OR WITHIN 1000 FEET OF A RUNWAY END.
WHEN SO AUTHORIZED TO PERFORM CONSTRUCTION ACTIVITIES WITHIN SUCH AREAS, THE
CONTRACTOR SHALL FIRST IMPLEMENT APPROPRIATE MARKING AND LIGHTING PROVISIONS.
3. EXCAVATION AND OPEN TRENCHES LOCATED WITHIN 250 FEET FROM THE CENTERLINE OF AN
ACTIVE RUNWAY SHALL BE ADEQUATELY SIGNED, MARKED AND LIGHTED. EXCAVATIONS AND
OPEN TRENCHES LOCATED ADJACENT TO TAXIWAY AND APRON PAVEMENT SHALL BE
ADEQUATELY SIGNED, MARKED AND LIGHTED.
4. DEBRIS SHALL NOT BE DEPOSITED ON ANY PORTION OF AN OPERATIONAL RUNWAY, TAXIWAY, OR
APRON. SHOULD ANY DEBRIS BE DEPOSITED ACCIDENTALLY, IT SHALL BE REMOVED
IMMEDIATELY.
5. OPEN-FLAME WELDING OR TORCH-CUTTING OPERATIONS ARE PROHIBITED UNLESS ADEQUATE
FIRE AND SAFETY PRECAUTIONS ARE PROVIDED AND HAVE BEEN APPROVED BY THE TRUAX FIRE
DEPT. ALL VEHICLES ARE TO BE PARKED AND SERVICED BEHIND THE CONSTRUCTION
RESTRICTION LINE 750 FEET OR MORE FROM AN ACTIVE RUNWAY CENTERLINE OR 200 FEET FROM
AN ACTIVE TAXIWAY CENTERLINE.
MARKING AND LIGHTING:
1. EXCAVATION/STOCKPILES-EXCAVATION ADJACENT TO PAVED SURFACES MUST BE
APPROPRIATELY MARKED BY BARRICADES.
2. CONTRACTOR SHALL BARRICADE OPEN EXCAVATIONS AS REQUIRED BY THE C.O.R.
FUEL SUPPORT:
1. ANY TYPE OF FUELING SUPPORT FACILITY OR DEVICE USED TO REFUEL CONSTRUCTION
EQUIPMENT IS SUBJECT TO WANG FIRE INSPECTION. LOCAL FIRE CODES AND SAFETY
STANDARDS SHALL BE MET PRIOR TO COMMENCEMENT OF WORK.
SWEEPING/CLEAN-UP:
1. THE CONTRACTOR SHALL HAVE SWEEPING OR VACUUMING CAPABILITIES ON-SITE AT ALL TIMES
IN ORDER TO REMOVE DEBRIS AS IT OCCURS. UPON COMPLETION, THE CONTRACTOR IS
RESPONSIBLE FOR INSURING THAT THE AREA OF CONCERN IS RETURNED TO ITS ORIGINAL
CONDITION.
HAUL ROUTES:
1. HAUL ROUTES AND ACCESS TO THE CONSTRUCTION SITES WILL BE DISCUSSED AT THE PRE-BID
CONFERENCE AND ARE DEPICTED ON G-001.
2. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS ON THE BASE IN A MANNER THAT WILL
MINIMIZE INTERFERENCE WITH THE NORMAL OPERATIONS OF AIRPORT FACILITIES THAT ARE TO
REMAIN OPEN TO AIR TRAFFIC, AND THE CONTRACTOR SHALL IMPLEMENT ALL SPECIFIED AND
OTHER APPROPRIATE MEASURES TO ENSURE THE SAFETY OF ALL USERS OF THE AIRPORT.
3. THE CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS CONTAINED WITHIN THE
SPECIFICATIONS.
4. CONTRACTOR SHALL NOT USE RADIO EQUIPMENT OR CELL PHONES WITHIN 400 FEET OF
AIRCRAFT.
ENFORCEMENT:
1. VIOLATION OF THESE RULES AND REGULATIONS, DEPENDING UPON SEVERITY OF THE VIOLATION, MAY RESULT IN ONE OR MORE OF THE FOLLOWING:
1.1. A VERBAL AND/OR WRITTEN WARNING.
1.2. REVOCATION OF AOA BADGE AND/OR VEHICLE ACCESS PERMIT.
1.3. THE CONTRACT WORK BEING STOPPED UNTIL CORRECTIVE MEASURES ARE TAKEN TO
PRECLUDE A RECURRENCE OF THE VIOLATION.
2. CONTRACTOR SHALL ALSO ABIDE BY ALL WANG REQUIREMENTS CONTAINED WITHIN THE
SPECIFICATION.
KEYED NOTES:
X.XXX
0.101 CONSTRUCTION ON B404 WILL BE OCCURRING AT SAME TIME AS B406.
COORDINATE PROJECT CONSTRUCTION AT SHARED PROJECT BOUNDARY
WITH BASE AND B404 PROJECT CONTRACTOR.
0.102 MAINTAIN PARKING LOT ENTRANCE FROM ROADWAY.
0.103 MAINTAIN ROADWAY ACCESS TO B420.
0.104 CONTRACTOR MAY UTILIZE SPACE BEYOND PROJECT EXTENT WHEN
ACTIVELY WORKING ON NORTHEAST OF BUILDING EXTERIOR. MAINTAIN A
MINIMUM 12' ROADWAY ACCESS FOR VEHICLES WHICH NEED TO ACCESS THE
AIRFIELD. MAINTAIN ACCESS TO PARKING STALLS FOR B420 OCCUPANTS.
0.105 MAINTAIN EXISTING BOLLARDS UNTIL INSTALLATION OF NEW GATE.
"OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION":
CONFORMS TO AC150/5370-2E
1. CONTRACTOR SHALL REMOVE FENCE AND PATCH PAVEMENT AND LANDSCAPING
DAMAGED FROM TRAILERS AND FENCING DURING PROJECT.
2. CONTRACTOR LAY DOWN AND TRAILER PARKING AREA SHOWN IS DIAGRAMMATIC AND
WILL BE DISCUSSED IN DETAIL WITH THE AWARDED CONTRACTOR DURING
PRE-CONSTRUCTION MEETING.
GENERAL NOTES:
3141300-190289.01
CONTRACTOR LAY DOWN AREA
C
O
N
T
R
A
C
T
O
T
A
I
L
E
P
A
R
K
I
N
G
| Sheets and Views |
| G-011 |
File details come from the government source that posted it. Updated .