TECH BINDER.pdf
PDF 6 MB Posted
- Attached to
- Z2DA--626A4-19-101 - Renovate Ward 1B at the Alvin C. York VA Medical Center, Murfreesboro, TN 37129
- Solicitation number
- 36C24923R0114
About this file
This solicitation is for renovations to Ward 1B at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The solicitation number is 36C24923R0114 and was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. Renovations include updating patient rooms, corridors, support spaces, and building systems on the third floor to improve patient care and comply with codes and standards. The work also involves phasing plans to minimize disruption during construction. The deadline for responses is not provided in the document.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLEAN UTILITY
SOILED UT.
PT. ROOM
PT. ROOM
PT. ROOM
PT. ROOM
ELEC.
STAFF TLT.STAIR
PT. ISO ROOM
PT. ROOM
PT. ROOM
WORK RM
ANTE
OFFICE
RESIDENTS RM.
MECH.
PT. ROOM
PT. ROOM
STOR. ROOM MEDS
SUPPLY ROOM
ELEC.
NOURISHMENT
CHUTE
IT
COMM
CONSULT
PT. ROOM PT. ROOM
PT. ROOM
PT. ROOM
MECH
OFFICE
RESIDENTS
ROOM
STAIR
PT. ROOM
PT. ROOM
PT. ROOM
WORK ROOM
CLEAN UTILITY
SOILED UTILITY
PT. ROOM
PT. ROOM
PT. ROOM
PT. ROOM
HAC ELEC.
STAFF TLT
NURSE WK.
NURSE STATION
SOCIAL WORK
WAITING ROOM
STAIRS
CHASE
LOCKER RM.
RETHERM
CONF.
STAFF TLT.
CORRID
STAFF BREAK
EXAMPLE #1
EXAMPLE LEGEND
EXAMPLE #2
EXAMPLE #3
EXAMPLE #4
EXAMPLE #5
EXAMPLE #6
ISO ROOM
PAT. TLT.
PRIVATE ROOM
PRIVATE ROOM
PRIVATE ROOM
BARI PRIVATE
ROOM
BARIATRIC
PATIENT TOILET
PRIVATE ROOM
PRIVATE ROOM
PANTRY
SERVING
KITCHEN
DINING/DAY
ROOM
LAUNDRY CLEAN SUPPLY
RETHERMCHUTE
EQUIP STORAGE
INPATIENT
REHAB
STAFF LOUNGE
STAFF LOCKERS
CHAIR ALCOVE
FAM. LOUNGE
CONSULT
FAM/PUB. TLT.
REC.THR. STOR.
TEAM ROOM
DATA
CLEAN LINEN
NOURISH
ST. TLT.
HAC.
SOILED HOLD
ELEC.
CLEAN UTILITY
HAC
WOUND CART
STOR.SUB NS.
PRIVATE ROOM
PRIVATE ROOM
ISO ROOM
CLEAN UTILITY
PAT. TLT.
ELEC.
EQUIP STOR.
TEAM WORKCLEAN LINEN
SOILED HOLD
BARI PRIVATE
ROOM
BARI. TLT.
NOURISHMENT
PAT. TLT.
PAT. TLT.
STAFF TLT.
PRIVATE ROOM
PAT. TLT.
PAT. TLT.
PAT. TLT.
PRIVATE ROOM
PAT. TLT.
PRIVATE ROOM
PRIVATE ROOM
PRIVATE ROOM
PAT. TLT.
PAT. TLT.
PAT. TLT.
PAT. TLT.
TEAM WORK
ROOM
SUB N.S.
CHARGE NURSE
NURSE STATION
SOCIAL WORKER
DIRTY
EMPTY CYL.
STOR.
FULL CYL. STOR.
ANTE
NURSE
MANAGER
PAT. TLT.
PAT. TLT.
ANTE
MEDS
COMM
STAFF TLT.
PRIVATE ROOM PRIVATE ROOM
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
VENDING
PAT. TLT.
PAT. TLT.
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STAIR 1
STAIR 2
STAIR 3
EXISTING RISER
ELEV.
ELEV.
CHASE
CHASE
CHASE
CHASE
THE INTENT WITH THIS PLAN IS TO SHOW
HOW THE AREAS BETWEEN THE SECOND
FLOOR AND THRID FLOOR ALIGN
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2019
TLC No.:
www.tlc-engineers.com
118626
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C U s e rs \a tr a y lo r\ D o c u m e n ts
\M b o ro V
A W a rd b
R e n o a tr a y lo r2 X
N D
H .r v t
/1
/2
:5
:4
P
M
04-14-2023
626A4-19-101
GI 05.01
AE RENOVATE WARD 1BPHASING PLANS
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 SECOND FLOOR PLAN - PHASING PLAN
0 8' 16' 32'4'
2 03 THIRD FLOOR PLAN - PHASING PLAN
0 8' 16' 32'4'
GENERAL NOTE:
1. THE PHASING PLAN IS NOTED AS EXAMPLES TO GIVE THE CONTRACTOR AN
UNDERSTANDING OF HOW THE PHASING FOR THE PROJECT NEEDS TO BE
ADDRESSED. WHILE THEY ARE LISTED BY NUMBER THESE EXAMPLES CAN BE
CONDUCTED IN ANY SEQUENCE AS DEEMED NECESSARY FOR THE MOST EFFECIENT
PROCESS POSSIBLE.
2. IN GENERAL 5 PATIENT ROOMS AT ONE TIME ON THE FLOOR BELOW WILL BE ABLE
TO BE TEMPORARLY OUT OF COMMISSION TO WORK ON VERTICAL SERVICES, THERE
MUST BE AT LEAST 15 ACTIVE PATIENT ROOMS AT ALL TIMES.
3. ALL ROOMS THAT ARE BEING WORKED ON SHALL BE PROTECTED FROM DAMAGE
AS BEST AS POSSIBILE. MOST OF THE WORK WILL TAKE PLACE IN THE CEILING,
HOWEVER DAMAGE TO ANY OTHER PART OF THE ROOM MUST BE REPARIED.
PROTECT EXISTING CEILING TILES, TILES THAT ARE DAMAGED OR BROKEN MUST BE
REPLACED TO THE ORIGINAL STATE.
4. CAREFUL COORDINATION WITH THE FACILITY MUST TAKE PLACE TO ADDRESS ANY
SHUTDOWNS THAT COULD EFFECT AREAS OUTSIDE OF THE DESIGNATED EXAMLE
ZONE.
5. IF SUPPORT SPACE INSIDE OF A DESIGNATED EXAMPLE ZONE IS SERVING
ANOTHER EXAMPLE ZONE COORDINATE SPECIFIC TIMES WITH THE FACILITY TO GAIN
ACCESS TO THIS SPACE.
6. ICRA BARRIERS MUST BE USED TO CLOSE OFF EACH AREA THAT IS BEING WORKED
ON TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM INFILTRATING OCCUPIED
SPACE. BARRIERS SHALL BE INSTALLED AND SEALED ALONG WITH STICKY MATS AND
ANY OTHER INFECTION CONTROL ITEMS. IN SOME INSTANCES ICRA BARRIERS MAY
BE REQUIRED PER ROOM.
7. WORK IN THE CONNECTING CORRIDORS, ELEVATOR LOBBY AND NURSE STATION
SHALL BE CAREFULLY COORDINATED WITH THE FACILITY AND STAFF. THE NEED TO
WORK IN THESE AREAS SHALL BE EVALUATED ON A AS NEEDED BASIS. ELEVATOR
ACCESS SHALL BE MAINTAINED AT ALL TIMES
No. Date Description jim.elder Rectangle jim.elder Typewritten Text 06-13-2023 jim.elder Rectangle jacob.kelsheimer Snapshot jacob.kelsheimer Snapshot
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:4
:4
A
M
06-13-2023
626A4-19-101
T-TJ-00
AE RENOVATE WARD 1BGENERAL TECHNOLOGY INFORMATION
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
DESCRIPTIONSYMBOLDESCRIPTIONSYMBOLDESCRIPTIONSYMBOL DESCRIPTIONSYMBOL
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT.
DESCRIPTIONSYMBOL
X
T
2.5
DELAYED EGRESSDE
AUDIO/VIDEO SYSTEM
REQUEST TO EXIT MOTION SENSOR
GLASS BREAK SENSOR
360° MOTION DETECTOR
PAN/TILT/ZOOM CCTV CAMERA,,
PROVIDE CAT6A CABLE,
FACEPLATE, AND DOUBLE GANG
JUNCTION BOX AND CONDUIT
SECURITY PANEL
DOOR POSITION SWITCH
BALANCED MAGNETIC SWITCH
ELECTRIC LATCH
ELECTRIC MORTISE/TRIM LOCK
ELECTRIC STRIKE
MAGNETIC LOCK
POWER OVER ETHERNET
CARDREADER/LOCK COMBO
REMOTE DOOR RELEASE BUTTON
ASSISTANCE STATION
DURESS BUTTON MOUNTED
UNDERSIDE OF
COUNTER
CCTV MONITOR
PHOTO ELECTRIC BEAM
INTERCOM MASTER STATION
DIRECTIONAL MOTION DETECTOR
FIXED CCTV CAMERA, PROVIDE
CAT6A CABLE, FACEPLATE, AND
DOUBLE GANG JUNCTION BOX AND
CONDUIT
P
BASIC MATERIALS
J
J
TECHNOLOGY SYSTEMS SYMBOL LEGEND
J
SECURITY SYSTEM
LADDER TRAY FOR HORIZONTAL
CABLING.
PENETRATION CONDUIT
SLEEVE WITH
BUSHINGS.
GENERAL NOTES
EXISTING TO BE REMOVED
EXISTING TO REMAIN
EXISTING AFFECTED BY THIS
PROJECT
FUTURE
SLEEVE TURNING DOWN
SLEEVE TURNING UP
GROUND OR GROUND ROD AS
NOTED
FLEXIBLE CONDUIT
CONDUIT CONTINUED
CONDUIT STUB
CONDUIT TURNING DOWN
CONDUIT TURNING UP
CONDUIT CONCEALED IN SLAB,
UNDERGROUND OR UNDER
FLOOR
CONDUIT EXPOSED
CONDUIT CONCEALED
PEDESTAL MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
JUNCTION BOX
VOICE & DATA SYSTEM
BROADBAND TELEVISION SYSTEM
6 PORT TAP
8 PORT TAP
TERMINATION TAP
4 PORT TAP
2 PORT TAP
3 WAY SPLITTER
2 WAY SPLITTER
4 WAY SPLITTER
AMPLIFIER
DIRECTIONAL COUPLER
BIOMETRIC READER
INTRUSION ALARM KEYPAD
HIRSH SCRAMBLE KEYPAD
KEYPAD
CARD READER
LOCAL HORN STROBE ALARMSA
COMBINED CARD READER/KEYPAD
GENERAL SYSTEM NOTES
1. PRODUCTS SHALL BE OF MATERIALS THAT ARE SUITABLE FOR THE
ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED.
2. WORKING CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL BE
MAINTAINED IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE
110, COORDINATE EQUIPMENT INSTALLATION TO MAINTAIN REQUIRED
CLEARANCES.
3. IF AN OUTLET BOX IS REQUIRED TO BE LOCATED IN AN ASSEMBLY OR PARTITION
RATED AS "FIRE/SMOKE" OR "SMOKE" OR IDENTIFIED AS EITHER "FIRE/SMOKE"
OR "SMOKE", THEN ALL OF THE FOLLOWING CONDITIONS SHALL BE MET:
THE OUTLET BOX OPENINGS SHALL OCCUR ONLY ON ONE SIDE OF THE
FRAMING SPACE.
THE OUTLET BOX SHALL BE METALLIC.
THE OUTLET BOX OPENINGS SHALL NOT EXCEED 16 SQUARE INCHES.
ALL CLEARANCES BETWEEN THE OUTLET BOX AND THE WALL BOARD
MATERIAL SHALL BE COMPLETELY SEALED WITH APPROVED MATERIALS IN
ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS FOR THE
PROJECT.
PROVIDE A SUPPLEMENTAL BARRIER AROUND OUTLETS LARGER THAN 16
INCHES SO THAT THE ORIGINAL RATING OF THE PENETRATION IS
MAINTAINED.
THE TOTAL AGGREGATE SURFACE AREA OF THE OUTLET BOX SHALL
NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET.
THE OUTLET BOX SHALL BE SEPARATED FROM OPENINGS ON THE
OPPOSITE SIDE OF THE RATED PARTITION BY A MINIMUM
HORIZONTAL DISTANCE OF 24 INCHES.
THE OUTLET BOX SHALL BE SECURELY FASTENED TO A PARTITION
FRAMING MEMBER BY MEANS OF AN APPROVED ATTACHMENT
METHOD.
OPENINGS CUT INTO THE WALL BOARD MATERIAL SHALL NOT
EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX
AND THE EDGES OF THE OPENING.
A.
B.
C.
D.
E.
F.
G.
H.
I.
LOCATIONS OF EQUIPMENT SHOWN ON THE DRAWINGS ARE
APPROXIMATE, COORDINATE EXACT EQUIPMENT LOCATION AND
CONNECTION REQUIREMENTS WITH THE APPROPRIATE TRADE PRIOR TO
INSTALLATION.
FOR EXACT LOCATION OF CEILING MOUNTED EQUIPMENT REFER TO THE
ARCHITECTURAL REFLECTED CEILING PLAN. LOCATIONS OF EQUIPMENT
NOT INCLUDED ON THE REFLECTED CEILING PLAN SHALL BE COORDINATED
WITH THOSE ITEMS SHOWN. COORDINATION OF CEILING MOUNTED
EQUIPMENT SHALL BE PRIOR TO ANY ROUGH-IN. NOTIFY ENGINEER OF ANY
DISCREPANCY.
PROVIDE FINAL CONNECTIONS TO VA PROVIDED EQUIPMENT WHERE
INDICATED ON THE PLAN DRAWINGS.
PRIOR TO ROUGH-IN AND INSTALLATION OF ANY FLOOR MOUNTED
DEVICE, VERIFY LOCATION WITH THE COR.
VERIFY AND COORDINATE THE LOCATION OF REQUIRED OUTLETS
WITH OTHER TRADE DRAWINGS AND VA PROVIDED EQUIPMENT.
EACH TELEVISION OUTLET LOCATION SHOWN, SHALL HAVE A DOUBLE GANG
OUTLET BOX WITH A SINGLE GANG PLASTER RING AND (1) 1" CONDUIT
STUBBED UP TO AN ACCESSIBLE LOCATION ABOVE THE FINISHED CEILING OR
TO AN ACCESSIBLE CABLE TRAY WHERE PROVIDED.
THE DESIGNATION ''N.I.C.'' SHALL DENOTE ITEMS, WHICH ARE ''NOT IN CONTRACT''.
THE DESIGNATION ''U.S.C.'' SHALL DENOTE ITEMS, WHICH ARE ''UNDER SEPARATE
CONTRACT''.
THE DESIGNATION ''F.B.O.'' SHALL DENOTE ITEMS, WHICH ARE ''FURNISHED BY
OTHERS''.
THE DESIGNATION ''O.F.E.'' SHALL DENOTE ITEMS, WHICH ARE ''OWNER
FURNISHED EQUIPMENT''.
ALL RACEWAY SYSTEMS SHOWN TO SUPPORT THE INSTALLATION OF THE
DIVISION 27 EQUIPMENT SHALL BE PROVIDED BY THE ELECTRICAL INSTALLER.
PROVIDE COORDINATION FOR THE INSTALLATION OF THIS BE PROVIDED BY THE
ELECTRICAL INSTALLER.
THE SYMBOL LEGENDS SHOWN ON THIS SHEET ARE ALL INCLUSIVE,
SYMBOLS INCLUDED IN THE LEGENDS MAY OR MAY NOT BE USED IN
THESE PROJECT DRAWINGS.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
EACH VOICE/DATA OUTLET LOCATION SHOWN, SHALL HAVE A DOUBLE GANG
OUTLET BOX WITH A SINGLE GANG PLASTER RING AND (1) 1" CONDUIT STUBBED UP
TO AN ACCESSIBLE LOCATION ABOVE THE FINISHED CEILING, TO AN ACCESSIBLE
CABLE TRAY WHERE PROVIDED OR HOMERUN IN SLAB TO NEAREST
COMMUNICATIONS ROOM. WORK BY ELECTRICAL INSTALLER PER
SPECIFICATIONS.
EACH FLOOR MOUNTED VOICE/DATA OUTLET SHALL HAVE A SINGLE GANG SPACE
WITHIN THE FLOOR BOX AND (1) 1" CONDUIT CONCEALED IN SLAB STUBBED UP TO
AN ACCESSIBLE LOCATION ABOVE THE FINISHED CEILING OR TO AN ACCESSIBLE
CABLE TRAY WHERE PROVIDED. WORK BY ELECTRICAL INSTALLER PER
SPECIFICATIONS.
ALL BONDING AND GROUNDING ELEMENTS UTILIZED FOR STRUCTURED CABLING
SYSTEM SHALL BE IN COMPLIANCE WITH SPECIFICATIONS.
PROVIDE ALL SLEEVES AS REQUIRED FOR ALL LOW VOLTAGE CABLE
PATHWAYS. RESTORE THE FIRE RATING OF THE SURFACE.
AUDIO VISUAL INPUT/OUTPUT - WALL MOUNTED
WITH ADJACENT DEDICATED DUPLEX
RECEPTACLE BY
X = TYPE (A, B, C, ETC.) SEE DETAILS FOR
ADDITIONAL INFORMATION
PODIUM
X x
Y
X x Y x
SX
SX
OVERHEAD PROJECTOR WITH
SCREEN, SCREEN SIZE SHOWN ON
PLANS
OVERHEAD PROJECTOR -
CEILING MOUNTED
X - DENOTES TYPE
PULLDOWN PROJECTION SCREEN, SIZE
SPECIFIED ON PLANS
OVERHEAD PROJECTION SCREEN MOTOR
WALL SWITCH FOR MOTORIZED SCREEN
CEILING MOUNTED SPEAKER
x DENOTES TYPE y DENOTES ZONE
TELECOMMUNICATIONS EQUIPMENT ROOMTER:
TR: TELECOMMUNICATIONS ROOM
TELECOMMUNICATIONS ENTRANCE FACILITYTEF:
NOTES:
INSTALLER TO REMOVE ALL EXISTING LOW VOLTAGE CABLES NOT TO BE
REUSED. E.G. ALL EXISTING UTP 4 PAIR CABLES. NO ABANDONED CABLES
SHALL BE LEFT IN THE BUILDING.
MOUNTING 2" ABOVE COUNTER OR BACK SPLASH
C
1. VOICE/DATA JACKS:
EACH RJ45 JACK FOR VOICE/DATA SHALL BE
CONNECTED TO A DEDICATED UTP 4 PR CABLE.
COMMUNICATIONS "INFORMATION OUTLET" MOUNTED AT
RECEPTACLE HEIGHT UNLESS OTHERWISE NOTED. MODULE
AND FACEPLATE DESCRIPTIONS ON DETAIL SHEETS
NNX
X = MOUNTING (F)LUSH, (S)URFACE, (M)ODULAR FURNITURE
ADAPTER (P)OLE, (R)ACEWAY, (D)OUBLE GANG FLUSH, (PD)
PEDESTAL
N = # OF VOICE/DATA JACKS
WALL TELEPHONE OUTLET FOR HOUSE PHONE.
MOUNTED AT 52" ABOVE FINISHED FLOOR TO TOP.
WIRELESS ACCESS POINT OUTLET. ACCESS POINT BY
OWNER.
X = MOUNTING (F)LUSH, (S)URFACE, (C)EILING.
N = # OF DATA JACKS. MAXIMUM CABLE LENGTH 262 FT
N
N = # OF COAX CONNECTORS "F" TYPE CONNECTOR
N = # OF FIBER OPTIC CONNECTORS. SC, ST, LC
REX OR ADA DOOR OPEN BUTTON
AUDIO/VIDEO CAMERAAV
ASSOCIATED DOOR DETAIL REFERENCE
INGROUND PULL BOX
MON
PERSONAL COMPUTER WORKSTATION
SPECIAL NOTES:
W F1
WALL MOUNTED OUTLET FOR ADA ACCESSABLE PAY
PHONE. MOUNTED AT 44" ABOVE FINISHED FLOOR
WAP
XON
WALL TELEPHONE OUTLET FOR TELEPHONE IN ELEVATOR
MACHINE ROOM. (S)URFACE MOUNTED AT 52" ABOVE
FINISHED FLOOR.
W
ADA
S1
ELV
COMBINED VOICE/DATA, AUDIO/VIDEO AND POWER OUTLETS IN
FLOOR BOX. POWER RECEPTACLE IS SHOWN FOR
REFERENCE ONLY. CONDUIT, BOX AND POWER RECEPTACLE
PROVIDED BY
X = A, B, C... FLOOR BOX TYPE. N'S ARE DESCRIBED ABOVE.
TB
TABLE TOP POP-UP WITH VOICE/DATA, AUDIO/VIDEO AND
POWER INTERFACE.
X = A, B, C... FLOOR BOX TYPE. N'S ARE DESCRIBED ABOVE.
POKE THRU WITH COMBINED VOICE/DATA,
AUDIO/VIDEO AND POWER.
X = A, B, C... FLOOR BOX TYPE. N'S ARE DESCRIBED
ABOVE.
P
3/4" PLYWOOD BACKBOARD. BY
IDF - 2 POST RACK
IDF - 4 POST RACK
TELECOMM PANEL
1.
ALL CABLE TRAY, CONDUITS AND BOXES SHOWN ARE IN CONTRACT BY THE
ELECTRICAL INSTALLER. J-HOOKS AND LADDER RACKS BY SCS INSTALLER.
2.
STRUCTURED CABLING SYSTEM BY CABLING INSTALLER.
3.
ALL DOUBLE DOORS ARE TO RECEIVE (1)
DOOR POSITION SWITCH ON EACH
DOOR LEAF AND SHALL REPORT AS ONE
ALARM POINT.
1.
2.
FIBER CCTV LOCATION WHICH EXCEEDS 3000 FEET SHALL BE EQUIPPED WITH 2
FIBER CONNECTIONS 1 VIDEO, 1 DATA
3.
A. THE MAXIMUM PULLING TENSION SHALL NOT EXCEED 25 POUNDS TO
AVOID STRETCHING THE CONDUCTORS.
THE MINIMUM BENDING RADIUS OF THE CABLE SHALL NOT BE
LESS THAN 4X THE OUTSIDE DIAMETER OF THE CABLE.
B.
THE CABLE SHALL BE INSTALLED WITHOUT KINKS OR TWISTS AND THE
APPLICATION OF CABLE TIES SHALL NOT DEFORM THE CABLE BUNDLE.
C.
D. STRIP BACK ONLY AS MUCH CABLE JACKET AS IS REQUIRED TO
TERMINATE THE CABLE. CABLE PAIRS SHALL NOT BE UNTWISTED
MORE THAN 1/2 INCH.
4.
5.
6.
7.
ALL 120V POWER WIRING SHALL BE INSTALLED IN A SEPARATE CONDUIT.
ALL POWER CIRCUITS, 120VAC AND 24VAC, SHALL INCLUDE AN EQUIPMENT
GROUNDING CONDUCTOR WHICH IS EQUAL IN SIZE TO THE PHASE AND
NEUTRAL CONDUCTORS.
ALL CONDUIT ABOVE GRADE SHALL BE METALLIC, ALL CONDUIT BELOW GRADE
SHALL BE PVC UNLESS OTHERWISE NOTED ON DRAWINGS.
ALL CARD READERS AND KEYPADS DEDICATED FOR ELEVATOR FLOOR
SELECTION CONTROL ARE SHOWN INSIDE THE ELEVATOR CAB ON THE
LOWEST LEVEL FLOOR PLAN TO WHICH THE ELEVATOR
TRAVELS.
ALL CONDUIT, WIRING, AND ASSOCIATED BACK BOXES SHALL BE FULLY
CONCEALED WITHIN WALLS, FLOORS, AND CEILINGS.
INSTALLATION OF UTP CABLE SHALL BE IN ACCORDANCE WITH
EIA/TIA GUIDELINES. CABLE INSTALLATION AND TERMINATIONS THAT
DO NOT COMPLY SHALL BE REPLACED BY THE INSTALLER.
8.
INSTALLATION OF FIBER OPTIC CABLES SHALL BE IN ACCORDANCE
WITH EIA/TIA GUIDELINES. CABLE INSTALLATION AND TERMINATIONS
THAT DO NOT COMPLY SHALL BE REPLACED BY THE INSTALLER.
9.
A. THE BEND RADIUS FOR INTRABUILDING 2 AND 4-FIBER
HORIZONTAL OPTICAL FIBER CABLE SHALL NOT BE LESS THAN 1
INCH UNDER NO-LOAD CONDITIONS. WHEN UNDER A MAXIMUM
TENSILE LOAD OF 50 LBF, THE BEND RADIUS SHALL NOT BE LESS
THAN 2 INCHES.
B. THE BEND RADIUS FOR INTRABUILDING OPTICAL FIBER BACKBONE
SHALL NOT BE LESS THAN THAT RECOMMENDED BY THE
MANUFACTURER IF NO RECOMMENDATION IS KNOWN, THEN THE
APPLIED BEND RADIUS SHALL NOT BE LESS THAN 10 TIMES THE
CABLE OUTSIDE DIAMETER
UNDER NO-LOAD CONDITIONS AND NOT LESS THAN 15 TIMES THE
CABLE OUTSIDE DIAMETER WHEN THE CABLE IS UNDER TENSILE
LOAD.THE BEND RADIUS FOR INTER BUILDING (OSP) OPTICAL FIBER BACKBONE
SHALL NOT BE LESS THAN THAT RECOMMENDED BY THE MANUFACTURER
IF NO RECOMMENDATION IS KNOWN, THEN THE APPLIED BEND RADIUS
SHALL NOT BE LESS THAN 10 TIMES THE CABLE OUTSIDE DIAMETER NO-
LOAD CONDITIONS AND NOT LESS THAN 20 TIMES THE CABLE OUTSIDE
DIAMETER WHEN THE CABLE IS UNDER A TENSILE LOAD UP TO THE RATING
OF THE CABLE, USUALLY 600 LBF.
C.
10. COORDINATE LOCATION OF ALL FIRE RATED PENETRATIONS PRIOR TO
PROCEEDING WITH INSTALLATION. ALL PENETRATIONS THROUGH FIRE
RATED BARRIERS SHALL BE COMPLETELY SEALED WITH APPROPRIATE
FIRE STOP MATERIAL IN ACCORDANCE WITH NFPA AND FIRE AUTHORITY
HAVING
JURISDICTION.
ALL CABLES SHALL BE SUITABLE TO THE ENVIRONMENT TO WHERE THEY WILL
BE INSTALLED.
NOTES:
ALL RACEWAYS AND BOXES SHOWN ARE IN CONTRACT
BY THE ELECTRICAL INSTALLER.
1.
AUDIO/VIDEO DEVICES AND EQUIPMENT BY THE
AUDIO/VIDEO INSTALLER.
2.
NOTES:
INSTALLER TO REMOVE ALL EXISTING SECURITY
CABLES AND EQUIPMENT NOT TO BE REUSED.
ALL EXISTING EQUIPMENT WILL BE RETURNED
TO THE OWNER.
1. ALL RACEWAYS AND BOXES SHOWN ARE IN
CONTRACT BY THE ELECTRICAL INSTALLER.
2. SECURITY DEVICES AND EQUIPMENT BY
SECURITY INSTALLER.
3.
CEILING MOUNTED DOCUMENT CAMERA
X = A, B, C... INTERFACE TYPE.
X
ASSISTED LISTENING TRANSMITTER
TOUCH SCREEN AUDIO/VIDEO CONTROL
WALL MOUNTED TOUCH SCREEN AUDIO/VIDEO
CONTROL
Y
WALL MOUNTED SPEAKER
x DENOTES TYPE y DENOTES ZONE
NO ZONE DENOTES LOCAL AUDIO/VIDEO SYSTEM
Y
SPEAKER - DEMOLITION PLAN
VOLUME CONTROL. PROVIDE 3/4" CONDUIT
STUB-UP ABOVE CEILING AND SINGLE
STANDARD ELECTRICAL BOX
AT 52" ABOVE FINISHED FLOOR
CEILING MOUNTED MICROPHONE OUTLET
x DENOTES TYPE y DENOTES ZONE
MX
Y
MX WALL MOUNTED MICROPHONE
x DENOTES TYPE y DENOTES ZONE
NO ZONE DENOTES LOCAL AUDIO/VIDEO SYSTEM
Y
MICROPHONE - DEMOLITION PLAN
SATELLITE DISHSD
CALL STATION
SEE PODIUM DETAILS
CS
IK
AS
DURESS BUTTON WALL MOUNTED
X x Y MOTORIZED PROJECTION SCREEN, SIZE
SPECIFIED ON PLANS
XNNN
XNNN
XNNN
D
MX SURFACE MOUNTED MICROPHONE
x DENOTES TYPE y DENOTES ZONE
NO ZONE DENOTES LOCAL AUDIO/VIDEO SYSTEM
Y
ALL INDOOR CONDUITS N0 LARGER THAN 1" SHOWN ON THE GROUND FLOOR
SHALL BE INSTALLED EMBEDDED IN THE SLAB. CONDUITS SHALL BE KEPT DRY
AND CLEAN PRIOR TO PULLING CABLES.
ANYTHING NOT DESIGNATED AS ROUGH-IN AND SUPPORT RESPONSIBILITY
ON THESE DRAWINGS IS IN THE SYSTEM INSTALLER SCOPE OF WORK.
INTERCOM & PAGING SYSTEM
SX
SX
CEILING MOUNTED SPEAKER
x DENOTES TYPE y DENOTES ZONE
Y
WALL MOUNTED SPEAKER
x DENOTES TYPE y DENOTES ZONE
NO ZONE DENOTES LOCAL AUDIO/VIDEO SYSTEM
Y
ADMINISTRATIVE PHONEAP
HANDSETHS
11. ALL DELAYED EGRESS LOCKS AND MAGNETIC LOCKS, SHALL
RECEIVE A FIRE ALARM RELAY TO RELEASE THE DOOR UPON ALARM
AS REQUIRED BY CODE.
SEE DETAIL SHEETS FOR DEVICE MOUNTING REQUIREMENTS AND ADDITIONAL
INFORMATION.
THE DESIGNATION "D.H.C." SHALL DENOTE "DOOR HARDWARE INSTALLER".14.
IN ELECTRICAL AND MECHANICAL ROOMS, CONDUIT FOR LOW VOLTAGE
OUTLETS SHALL BE EXTENDED TO ACCESSIBLE CEILING OUTSIDE OF THE ROOM.
X
DETENTION LOCKDL
DOOR INTERLOCKDI
INTERCOM SUBSTATION
SPEAKER PHONE
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
THE DESIGNATION "O.F.C.I." SHALL DENOTE ITEMS WHICH ARE FURNISHED
BY THE OWNER AND INSTALLED BY THE CONTRACTOR.
15.
M
S
DPS
BMS
CR
KP
CK
HS
BR
EL
EM
ES
ML
PE
IS
SP
D
MI
M
G
R
PC
S
AV
ALT
TS
TS
VC
DIVISION 27
DIVISION 27
DIVISION 26.
DETENTION DOOR INTERLOCKI
DIVISION 28
CABLE TRAY FOR HORIZONTAL
CABLING.
DIVISION 26
DIVISION 27
DIVISION 27
DIVISION 27
DIVISION 26
N
XX"
N = FACEPLATE CONNECTIVITY AND MOUNTING
TYPE, SEE DETAILS FOR INFORMATION
(TYPE 1,2,3, ETC.)
MONITOR SIZE IF APPLICABLE, SEE DETAILS
FOR INFORMATION
TV
AUDIO VISUAL INPUT/OUTPUT -SURFACE OR
FLOOR BOX MOUNTED WITH ADJACENT
DEDICATED DUPLEX RECEPTACLE BY
X = TYPE (A, B, C, ETC.) SEE DETAILS FOR
ADDITIONAL INFORMATION
X
AV
DIVISION 26
TELEVISION/MONITOR OUTLET, SEE DETAILS
FOR MOUNTING HEIGHT
SECURITY CAMERA EXTERIOR POLECP
PRESS CONNECTION PANEL, SEE DETAILS FOR
ADDITIONAL INFORMATION
PR
SECURITY SYSTEM NOTES
INDICATES WALL MOUNT
INDICATES WALL MOUNT
SECURITY CAMERA NETWORK OUTLET. COORDINATE
EXACT LOCATION OF OUTLET WITH OWNER PRIOR TO
ROUGH IN.
N = # OF DATA JACKS. MAXIMUM CABLE LENGTH 262 FT
CN
360 DEGREE CAMERA
MON
CMON
PAITENT MONITORING OUTLET - (1) CAT6
CENTRAL MONITOR OUTLET - (4) CAT6
CAT6
CAT6
CAT6
TECHNOLOGY DRAWING INDEX
SHEET DESCRIPTION ISSUED
T-TJ-00 GENERAL TECHNOLOGY INFORMATION Yes
T-TD-01 PARTIAL THIRD FLOOR PLAN - PART A - TECHNOLOGY DEMO Yes
T-TD-02 PARTIAL THIRD FLOOR PLAN - PART B - TECHNOLOGY DEMO Yes
T-TD-03 PARTIAL THIRD FLOOR PLAN - PART C - TECHNOLOGY DEMO Yes
T-TJ-01 PARTIAL THIRD FLOOR PLAN - PART A - TECHNOLOGY NEW WORK Yes
T-TJ-02 PARTIAL THIRD FLOOR PLAN - PART B - TECHNOLOGY NEW WORK Yes
T-TJ-03 PARTIAL THIRD FLOOR PLAN - PART C - TECHNOLOGY NEW WORK Yes
T-TJ-04 TECHNOLOGY - ENLARGED ROOMS Yes
T-TJ-06 TECHNOLOGY - DETAILS Yes
T-TJ-07 TECHNOLOGY - DETAILS Yes
T-TJ-08 TECHNOLOGY - RISER Yes
GI 05-01 PHASING PLANS Yes
No. Date Description
X3 X3
X4
X9
X10
X11
X12
X13
X14
XH XI XJ
XK
XL XM XN XO
XP
XQ XR XS
X6.1
X7.1
X12.1
X12.2 X12.3
X8
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
EXISTING PA
EXISTING CATV
EXISTING RISERS TO REMAIN
EXISTING FIBER, CATV AND PA RISER TO BE REROUTED
TO NEW DATA ROOM AND NEW COMM ROOM.
EXISTING TELE 308
EXISTING TELE 343
EXISTING PA TO BE ROUTED THROUGH TELE
CHASE 308 AS PART OF WARD 1A PROJECT.
CATV CABLE AND FIBER RISERS FOR THE 4TH FLOOR ARE TO BE
REROUTED UP EXISTING RISER B1-308 AS PART OF WARD 1A PROJECT.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:1
A
M
06-13-2023
626A4-19-101
T-TD-01
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART A -
TECHNOLOGY DEMO
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PLAN - PART A - DEMO
DEMOLITION GENERAL NOTES:
1. CONTRACTOR TO REMOVE EXISTING CEILING MOUNTED AV EQUIPMENT AND TURN OVER TO VA.
2. REMOVE AND TURN OVER TO VA ALL EXISTING WIRELESS ACCESS POINTS AND PUBLIC ADDRESS SPEAKERS.
3. REMOVE ALL EXISTING DATA CABLING.
4. REMOVE AND TURN OVER TO VA ALL NURSE CALL HEAD END EQUIPMENT.
X1X1
X2 X2
X3 X3
X4
X9
X10
X11
X0 X0
XB XC XD XE XF XG XH XI XJ
XK
X6.1
X7.1
X12.2 X12.3
X8
XA
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
DEMO EXISTING TELCO TERM
EXISTING TELCO RISER TO BE REROUTED
THROUGH ELECTRICAL ROOM B1-352.
EXISTING TELE 350
CATV CABLE RISERS FOR THE 4TH FLOOR ARE TO BE REROUTED
UP EXISTING RISER B1-308 AS PART OF WARD 1A PROJECT.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:1
A
M
06-13-2023
626A4-19-101
T-TD-02
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART B -
TECHNOLOGY DEMO
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PLAN - PART B - DEMO
DEMOLITION GENERAL NOTES:
1. CONTRACTOR TO REMOVE EXISTING CEILING MOUNTED AV EQUIPMENT AND TURN OVER TO VA.
2. REMOVE AND TURN OVER TO VA ALL EXISTING WIRELESS ACCESS POINTS AND PUBLIC ADDRESS SPEAKERS.
3. REMOVE ALL EXISTING DATA CABLING.
X1X1
X2 X2
X3 X3
X4
X9
X10
X11
X0 X0
XQ XR XS XT XU XV XW XX XY
X6.1
X7.1
X12.2
XZ
X8
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
DEMO EXISTING
NURSE CALL
EXISTING
TELE 335
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:2
A
M
06-13-2023
626A4-19-101
T-TD-03
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART C -
TECHNOLOGY DEMO
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PLAN - PART C - DEMO
DEMOLITION GENERAL NOTES:
1. CONTRACTOR TO REMOVE EXISTING CEILING MOUNTED AV EQUIPMENT AND TURN OVER TO VA.
2. REMOVE AND TURN OVER TO VA ALL EXISTING WIRELESS ACCESS POINTS AND PUBLIC ADDRESS SPEAKERS.
3. REMOVE ALL EXISTING DATA CABLING.
CR CR
C R
R R
R
T V
T V
T V
T V
S1
S1
S1
S1
S1
S1 S1
S1
S1
S1
S1
S1 S1
S1
S1
S1
S1
ES ES
ES
DPS
D P
S
D P
S
S1
S1
T V
CR
ES
D P
S
R
X3 X3
X4 X4
X9 X9X11
X12
X13
X14
XH XI XJ
XK
XL XM XN XO
XP
XQ XR XS
X6.1 X6.1
X7.1 X7.1
X12.1
X12.2
X12.3
X8 X8
X5 X5
X6 X6
X7 X7
PANTRY
B338A
SERVING KITCHEN
B338
DINING/DAY ROOM
B337
RETHERM
B361
LAUNDRY
B359 CLEAN SUPPLY
B363
CHUTE
B360
NURSE STATION
B336
EQUIP STORAGE
B301
INPATIENT REHAB
B303
STAFF LOUNGE
B304
STAFF LOCKERS
B304B
CHAIR ALCOVE
B305
FAM. LOUNGE
B307
CONSULT
B310
FAM/PUB. TLT.
B308
REC.THR. STOR.
B309
TEAM ROOM
B332
DATA
B335
PAT. TLT.
B331A
PRIVATE ROOM
B331
CHARGE NURSE
B336A
SOCIAL WORKER
B302
DIRTY
B362
NURSE MANAGER
B333
MEDS
B336B
COMM
B334
STAFF TLT.
B304A
CORRIDOR
B300
CORRIDOR
B370
VENDING
B300A
EXISTING RISER
B370A
ELEV.
ELEV.
STAIR 1
STAIR 1
B306
WAP
S 2
WAP
S 2
WAP
S 2
WAP
S 2
J-HOOK PATHWAY
J-HOOK PATHWAY
C F 2
F 1
F 3
F 3
F 1
F 1
F 1
W F 1
W F 1
F 2
F 2
F 2 F 2
F 2
F 2
?W F 1
F 4 F 4 F 4F 4
F 4 F 4
F 4 F 4
F 2
F 2
F 2
F 2
360 DEGREE CAMERAS
360 DEGREE CAMERA
F 4
F 2
F 1
F 2
F 2
F 2 F 2
@ 66" A.F.F. CENTERED BEHIND DISPLAY.
SEE DETAIL 5 ON SHEET T-TJ-07
@ 66" A.F.F. CENTERED
BEHIND DISPLAY. SEE
DETAIL 5 ON SHEET T-TJ-07
@ 74" A.F.F. CENTERED BEHIND DISPLAY.
SEE DETAIL 5 ON SHEET T-TJ-07
4" HILTI SLEEVES
AS REQUIRED
J-HOOK PATHWAY
J-HOOK PATHWAY
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
F 2
F 2 F 2
F 4 F 4
F 1
F 1
F 2
F 1 F 1 1 1
J-HOOK PATHWAY
J-HOOK PATHWAY
F 1
DATA FOR OWNER
PROVIDED LEAF
SYSTEM +80" A.F.F.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:2
A
M
06-13-2023
626A4-19-101
T-TJ-01
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART A -
TECHNOLOGY NEW WORK
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PLAN - PART A
TECHNOLOGY KEYED NOTES
DATA OUTLET FOR REESE MONITORING SYSTEM TO BE LOCATED ABOVE DOOR
AND CABLED BACK TO NEAREST DATA ROOM. COORDINATE LOCATION OF
TERMINATION IN DATA ROOM WITH OWNER IT.
T V
S1 S1
S1
S1S1
S1
S1S1
S1
S1
S1
S1
S1
S1
T
VT
V
T V
T V
TV
TV
TV
TV
PRIVATE ROOM
B349
PRIVATE ROOM
B348
ISO ROOM
B347
CLEAN UTILITY
B346
ELEC.
B344
EQUIP STOR.
B343
CLEAN LINEN
B351
SOILED HOLD
B352
BARI PRIVATE
ROOM
B355
BARI. TLT.
B355A
NOURISHMENT
B356
SUB NS.
B358
HAC
B357
STAFF TLT.
B358A
PANTRY
B338A
SERVING
KITCHEN
B338
DINING/DAY
ROOM
B337
RETHERM
B361
LAUNDRY
B359
CLEAN SUPPLY
B363
CHUTE
B360
X1X1
X2 X2
X3 X3
X4
X9
X10 X10
X11
X0 X0
XB XC XD XE XF XG XH XI XJ
XK
X6.1
X7.1
X12.2
X12.3
X8
XA
X5
X6
X7
CORRIDOR
B374
CORRIDOR
B375
TEAM WORK
B341
DIRTY
B362
ANTE
B347A
PRIVATE ROOM
B354
PRIVATE ROOM
B353
PAT. TLT.
B354A
PAT. TLT.
B353A
PRIVATE ROOM
B339
PRIVATE ROOM
B340
D N
PRIVATE ROOM
B350
PAT. TLT.
B349A
PAT. TLT.
B340A PAT. TLT.
B339A
PAT. TLT.
B350A
PAT. TLT.
B348A
PAT. TLT.
B347B
CORRIDOR
B376
STAIR 2
CHASE
B338B
3'-0"
STAIR 2
B345
MON
J-HOOK PATHWAY
J-HOOK PATHWAY
WAP
S 2
WAP
S 2
WAP
S 2
WAP
S 2
WAP
S 2
F 2
F 2
F 1
F 2
F 2F 2
F 2
F 2
F 2
F 2 F 2
F 2
F 2 F 4F 4
F 2
F 4
F 4
F 4 F 4
W F 1
360 DEGREE CAMERA
360 DEGREE CAMERA
360 DEGREE CAMERA
F 2
F 2
MON
F 2
MONMON
MON
F 2
F 2
F 2
F 2 F 2
F 2F 2
F 2 F 2
MON
F 2
F 2F 2
MON
F 2
F 2F 2
MON
F 2
F 2F 2
F 2 F 2MON
F 2
F 1
F 1
F 1
F 1
F 1F 1 F 1 F 1
COORDINATE EXACT MOUNTING HEIGHT
OF ALL DEVICES IN PATIENT ROOMS
WITH ARCHITECTURAL DRAWINGS.
(TYP.)
J-HOOK PATHWAY
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
F 1
F 1F 1
F 1 2
F 1
DATA FOR OWNER
PROVIDED LEAF
SYSTEM +80" A.F.F.
F 1
DATA FOR OWNER
PROVIDED LEAF
SYSTEM +80" A.F.F.
F 1
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:2
A
M
06-13-2023
626A4-19-101
T-TJ-02
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART B -
TECHNOLOGY NEW WORK
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PLAN - PART B
TECHNOLOGY KEYED NOTES
DATA OUTLET FOR OWNER PROVIDED REESE MONITORING SYSTEM TO BE LOCATED
ABOVE DOOR AND CABLED BACK TO NEAREST DATA ROOM. COORDINATE LOCATION
OF TERMINATION IN DATA ROOM WITH OWNER IT.
DATA OUTLET FOR ALEX DISPENSER UNIT SYSTEM AT 81" A.F.F. TO THE BOTTOM.
COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH IN.
COORDINATE EXACT LOCATION OF DATA OUTLETS ON HEADWALL & FOOTWALL WITH
ARCHITECTURAL DRAWINGS PRIOR TO ROUGH IN.
S1
S1
S1
S1 S1
S1
S1 S1
S1
S1
S1
S1
S1
T V
T V
T V
T V
T V
TV
TV
TV
TV
TEAM ROOM
B332
REC.THR. STOR.
B309
CONSULT
B310
FAM/PUB. TLT.
B308
PRIVATE ROOM
B331
PAT. TLT.
B331A
PAT. TLT.
B330A
PRIVATE ROOM
B330
TEAM WORK
ROOM
B329
WOUND CART
STOR.
B311B
ST. TLT.
B311A
CLEAN LINEN
B318
BARI PRIVATE
ROOM
B313
BARIATRIC
PATIENT TOILET
B313A
NOURISH
B312
CLEAN UTILITY
B320
ELEC.
B326
SOILED HOLD
B327
HAC.
B325
ISO ROOM
B321
PAT. TLT.
B322A
SUB N.S.
B311
X1X1
X2 X2
X3 X3
X4
X9
X10
X0 X0
XQ XR XS XT XU XV XW XX XY XZ
X8
X5
X6
X7
NURSE
MANAGER
B333
PAT. TLT.
B321B
PRIVATE ROOM
B322
EMPTY CYL.
STOR.
B317
FULL CYL. STOR.
B316
PAT. TLT.
B315A PAT. TLT.
B314A
ANTE
B321A
CORRIDOR
B371
CORRIDOR
B372
CORRIDOR
B373
PRIVATE ROOM
B314
PRIVATE ROOM
B315
PRIVATE ROOM
B324
PRIVATE ROOM
B323
PAT. TLT.
B323A
PAT. TLT.
B324A
STAIR 3
STAIR 3
B319
CHASE
B328
J-HOOK PATHWAY
J-HOOK PATHWAY
WAP
S 2
WAP
S 2
WAP
S 2
WAP
S 2
F 2
F 2
F 2F 2
F 2
F 2
F 2
F 2F 2 F 4
F 2
F 2
F 2
F 2
F 2
F 4
F 4
F 4
360 DEGREE CAMERA
360 DEGREE CAMERA
360 DEGREE CAMERA
F 2
F 2
F 2
MON
F 1
MON
F 2
F 2
F 2
F 2
MON
F 2
F 2
MON
F 2
F 2 F 2
F 2
MON
F 2
F 2
MONF 2 F 2
F 2 MON F 2
F 2 F 2MON
F 2F 2 MON
F 1
F 1
F 1
F 1
F 1
F 1F 1 F 1
F 2
F 2
F 2
F 2
F 2 F 2 F 2
F 2
COORDINATE EXACT MOUNTING HEIGHT OF ALL DEVICES
IN PATIENT ROOMS WITH ARCHITECTURAL DRAWINGS.
(TYP.)
J-HOOK PATHWAY
J-HOOK PATHWAY
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
?WAP
S 2
F 4 F 4
F 1
F 1
F 1
DATA FOR OWNER
PROVIDED LEAF
SYSTEM +80" A.F.F.
F 1
F 1
DATA FOR OWNER
PROVIDED LEAF
SYSTEM +80" A.F.F.
F 1
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:2
A
M
06-13-2023
626A4-19-101
T-TJ-03
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART C -
TECHNOLOGY NEW WORK
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PLAN - PART C
TECHNOLOGY KEYED NOTES
DATA OUTLET FOR OWNER PROVIDED REESE MONITORING SYSTEM TO BE LOCATED
ABOVE DOOR AND CABLED BACK TO NEAREST DATA ROOM. COORDINATE LOCATION
OF TERMINATION IN DATA ROOM WITH OWNER IT.
DATA OUTLET FOR ALEX DISPENSER UNIT SYSTEM AT 81" A.F.F. TO THE BOTTOM.
COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH IN.
COORDINATE EXACT LOCATION OF DATA OUTLETS ON HEADWALL & FOOTWALL WITH
ARCHITECTURAL DRAWINGS PRIOR TO ROUGH IN.
ELEC PANEL
TELEVISION AMP & TAPS. CONNECT TO
HEAD END LOCATED IN EXISTING COMM
ROOM 106 ON FIRST FLOOR - BUILDING 1
DDC
R A
D
IO
/D A
S
INTERCOM ABOVE PA
PUBLIC ADDRESS BELOW INTERCOM.
CONNECT TO HEAD END LOCATED IN EXISTING
COMM ROOM 106 ON FIRST FLOOR - BUILDING 1
SECURITY
NURSE CALL
GROUND
BUS BAR
4" HILTI SLEEVES
PLYWOOD BACKBOARD
COMM
B334
77 SF
2-POST
RACK
2-POST
RACK
4" HILTI SLEEVES
DATA OUTLET ABOVE DOOR FOR OWNER
PROVIDED REESE MONITORING SYSTEM
DATA
B335
GROUND BUS BAR
PLYWOOD BACKBOARD
TELECO TERM. FIBER AND
COPPER TERMINATIONS.
CONNECT TO BUILDING MDF
4" HILTI SLEEVES
4" HILTI SLEEVES
DATA OUTLET ABOVE DOOR FOR OWNER
PROVIDED REESE MONITORING SYSTEM
FIXED CAMERA, PAN /
TILT / ZOOM, PASSIVE
INFRARED CAMERA -
DUAL TECHNOLOGY
45RU, 30"D x 7'H x 23.75"W
NETWORK EQUIPMENT
RACK. MIGHTY MO 20
CABLE MANAGEMENT RACK
WITH WHITE FINISH OR
APPROVED EQUAL.
6" WIDE VERTICAL CABLE
MANAGEMENT. WHITE
MM20 VERTICAL CABLE
MANAGEMENT "CAGE" OR
APPROVED EQUAL
PLYWOOD BACKBOARD
LADDER RACK
F1 DATA FOR REESE
MONITORING SYSTEM
NURSE CALL
PLYWOOD BACKBOARD
LADDER RACK
TELEVISION
INTERCOM
PUBLIC ADDRESS
DDC
SECURITY
SECURITY
PLYWOOD BACKBOARD
LADDER RACK
ELEC
PLYWOOD BACKBOARD
LADDER RACK
GROUND
BUS BAR
RADIO OR DAS
LADDER RACK
PLYWOOD BACKBOARD
F1 DATA FOR REESE
MONITORING SYSTEM
4" HILTI SLEEVES
LADDER RACK
PLYWOOD BACKBOARD
LADDER RACK
PLYWOOD
BACKBOARD
4" HILTI SLEEVES
TELECOM
LADDER RACK
PLYWOOD BACKBOARD
GROUND
BUS BAR
COMM
B334
77 SF
DATA
B335
WIRE MESH CABLE TRAY - MINIMUM SIZE
OF 4" X 12" WITH SECOND LEVEL OF
FIBER CHANNEL PATHWAY (4" x 4")
24"
12"
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:3
A
M
06-13-2023
626A4-19-101
T-TJ-04
AE RENOVATE WARD 1BTECHNOLOGY - ENLARGED ROOMS
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/8" = 1'-0"
1 ENLARGED COMM ROOM
3/8" = 1'-0"
2 ENLARGED DATA ROOM
COMM ROOM ELECTRICAL DESIGN BASIS
Circuit Volts Amps Type TYP Load Description
1 220V 30A EMER 50% RACK 1 - FIBER / PATCH
2 120V 20A EMER 50% RACK 2 - BIOMED
3 120V 20A EMER 50% SECURITY
5 120V 20A EMER 50% INTERCOM
6 120V 20A EMER 50% PUBLIC ADDRESS
7 120V 20A EMER 50% NURSE CALL
8 120V 20A EMER 25% RADIO / DAS
9 120V 20A EMER 25% TELEVISION
10 120V 20A ROUTINE 25% CONVIENCE OUTLETS
DATA ROOM ELECTRICAL DESIGN BASIS
Circuit Volts. Amps. Type. TYP. Load Description.
1 220V 30A EMER 50% RACK 1 - FIBER / PATCH
2 120V 20A EMER 50% TELCO TERM.
3 120V 20A ROUTINE 25% CONVIENCE OUTLETS
3/8" = 1'-0"
3 COMM NORTH ELEVATION
3/8" = 1'-0"
4 COMM SOUTH ELEVATION
3/8" = 1'-0"
5 COMM EAST ELEVATION
3/8" = 1'-0"
6 COMM WEST ELEVATION
3/8" = 1'-0"
7 DATA NORTH ELEVATION
3/8" = 1'-0"
8 DATA SOUTH ELEVATION
3/8" = 1'-0"
9 DATA EAST ELEVATION
3/8" = 1'-0"
10 DATA WEST ELEVATION
3/8" = 1'-0"
11 ENLARGED COMM ROOM LADDER RACK
3/8" = 1'-0"
12 ENLARGED DATA ROOM LADDER RACK
1. CAMERA SHALL BE SUPPORTED FROM THE
CEILING GRID SYSTEM, NOT THE CEILING TILE.
PROVIDE MOUNTING HARDWARE AS REQUIRED.
NOTES:
SUPPORT BOX
WALL MOUNTED BOX
WITH CAT6
CONNECTION
MODULE.
CAT6 UTP,
4 PAIR
CABLE
LAY IN CEILING TILE
CEILING TEE'S
GRID SUPPORT PROVIDED
BY SCS CONTRACTOR
CEILING TILE WIRE
CONCRETE
DECK ABOVE
WIRE SHALL BE SUPPORTED
FROM LOOP SUPPORTS
SECURE SECONDARY
SUPPORT CABLE FROM
BUILDING STRUCTURE
SECONDARY SUPPORT TAB
3/4" CONDUIT
2 GANG BACK BOX
FIN. FL.
COORDINATE WITH
MOUNTING BRACKET
RG6 COAX
CAT 6A F-TYPE ADAPTER
SINGLE GANG FACE PLATE FOR (2) MODULES
TV
2) RANDOMLY INSTALL J-HOOKS AT 3', 4' AND 5'
APART.
TREE SYSTEM IS FOR MAIN CORRIDOR PATHWAYS.
DOUBLE AND SINGLE TREES MAYBE USED IN
ROOMS. CABLE J-HOOK SYSTEM CAN BE SECURED
TO METAL STUDS, WHERE PERMISSIBLE.
NOTES:
CADDY CABLE J-HOOKS
CONCRETE ANCHOR ROOF DECK
BAR JOIST CLAMP
1)
CEILING
M
IN
M
A X
STRUCTURED CABLING
SECURITY,
CCTV, MISC.
NURSE CALL, PUBLIC
ADDRESS, CATV
PROVIDE DOUBLE-GANG BOX
WITH SINGLE GANG MUD RING
FOR READER. SEE FLOOR PLAN
FOR SPECIFIC TYPE AND PLACEMENT.
PROVIDE DOUBLE-GANG BOX
WITH SINGLE GANG MUD RING
FOR READER. SEE FLOOR PLAN
FOR SPECIFIC TYPE AND
PLACEMENT.
44" A.F.F.
6"
44" A.F.F.
6"
ELECTRIC STRIKE AND
ACCOMMODATING
HARDWARE
FINISHED CEILING FINISHED CEILING
MAGNETIC DOOR CONTACT
SWITCH EMBEDDED IN
DOOR & DOOR FRAME
FINISHED FLOOR
DOOR HARDWARE SHOWN FOR GRAPHICAL ILLISTRATION ONLY, REFERENCE DIVISION 8 HARDWARE
SCHEDULE AS NEEDED FOR ACTUAL HARDWARE SET.
3.
ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED.2.
1.NOTES: CABLE TYPE AND SIZE MUST COMPLY WITH ALL ESTABLISHED REQUIREMENTS AND APPLICABLE CODES.
4" x 4" SQUARE J-BOX.
CABLE FOR COMMUNICATION
AND LOW VOLTAGE POWER
1" CONDUIT TO ACCESSIBLE CEILING
SPACE
UNSECURE SIDE SECURE SIDE
POWER
SUPPLY
PROVIDE
DOUBLE-GANG BOX
WITH SINGLE GANG
MUD RING
FOR READER. SEE
FLOOR PLAN
FOR SPECIFIC TYPE
AND PLACEMENT.
44" A.F.F.
6"
4" x 4" SQUARE J-BOX.
MAGNETIC DOOR
CONTACT
SWITCH EMBEDDED IN
DOOR & DOOR FRAME
ELECTRIC STRIKE
AND
ACCOMMODATING
HARDWARE
FINISHED FLOOR
FINISHED CEILING
DOOR HARDWARE SHOWN FOR GRAPHICAL ILLISTRATION ONLY, REFERENCE DIVISION 8 HARDWARE
SCHEDULE AS NEEDED FOR ACTUAL HARDWARE SET.
3.
ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED.2.
1.NOTES: CABLE TYPE AND SIZE MUST COMPLY WITH ALL ESTABLISHED REQUIREMENTS AND APPLICABLE CODES.
CABLE FOR COMMUNICATION
AND LOW VOLTAGE POWER
1" CONDUIT TO ACCESSIBLE CEILING
SPACE
ELECTRIFIED HINGE
(PROVIDED BY DOOR
HARDWARE
INSTALLER)
2" x 4" J-BOX FLUSH MOUNTED
FOR EGRESS MOTION SENSOR.
ROOM #
PORT #
TR # - PP #
TELEPHONE WALL PLATE
(1) UTP 4 PAIR
CAT6A CABLE TO TR.
W F1
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:3
A
M
06-13-2023
626A4-19-101
T-TJ-06
AE RENOVATE WARD 1BTECHNOLOGY - DETAILS
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
No Scale
CCTV CAMERA INSTALLATION1 1
No Scale
TV OUTLET 2
No Scale
CABLE HANGER (MULTI J-HOOK) 3No Scale 5
SECURITY SINGLE DOOR - ELECTRIC STRIKE WITH CARD READERS
No Scale 6
SECURITY DOUBLE DOOR - ELECTRIC STRIKE WITH CARD READER AND REX
No Scale
WALL PHONE OUTLET - W/FI 4
LABEL
1 1/2" EMT CONDUIT
STUBBED TO THE
NEAREST J-HOOK
AND GROMMET
BLDG # - SECTION # - FLOOR # - JACKID #
F4
CAT6 DATA CABLE
CAT6 DATA CABLE
CAT6 VOICE CABLE
CAT6 DATA CABLE
BLUE FOR DATA
BLUE FOR DATA
BLUE FOR DATA
BLUE FOR PHONE/FAX
CAT6A DATA CABLE WITH BLUE KEYSTONE
CAT6A DATA CABLE WITH BLUE KEYSTONE
CAT6A VOICE CABLE WITH WHITE KEYSTONE
CAT6A DATA CABLE WITH BLUE KEYSTONE
MAX
5'
(2) CAT6 UTP TO COMM/DATA ROOM
NOTE:
WIRELESS ACCESS POINT AND
ANTENNA NOT IN CONTRACT.
WAP
S2
J-HOOK
ACCESSIBLE CEILING
COIL 15' SERVICE LOOP IN CEILING.
DETAIL NOTE:
COIL CABLE IN CEILING
GROUND BUS BAR
STANDOFF
RACKET
CPI 10622-000
INSULATOR
CPI 10622-012 OR EQUAL
ISOMETRIC ELEVATION
PROVIDE # 6 COPPER CABLE 2-HOLE
LUG CLAMP FOR CABLE
CONNECTION. (TYP)
PROVIDE GROUNDING
CONDUCTOR TO
BUILDINGS
STEEL PER NEC 250.66
PROVIDE GROUNDING CONDUCTOR TO
MAIN SERVICE GROUND POINT PER NEC
250.66
4"
FRONT VIEW
INSULATOR (TYPICAL)
CPI 10622-012 OR EQUAL
12"
PROVIDED BY ELECTRICAL INSTALLER.
2-HOLE LUG (TYP.)
INSULATOR MOUNTING BRACKET
(TYP.) CPI 10622-000
PROVIDE WHITE CORE BAKELITE NAMEPLATE
FASTENED TO A WALL/SURFACE BELOW
BUSBAR AT EACH FLOOR, WITH DESIGNATION
ENGRAVED THEREON IN 1/2" HIGH LETTERS.
TGB-XXX
GENERAL NOTES:
ALL HARDWARE (BOLTS, NUTS,
WASHERS, ETC.) SHALL BE SOLID
COPPER OR BRONZE. COPPER
PLATING SHALL NOT BE ACCEPTABLE.
BUSBAR SHALL BE 1/4" THICK
(MINIMUM).
INCREASE LENGTH OF BUSBAR, FOR
NUMBER OF CONNECTIONS, AS
REQUIRED
TO MAINTAIN CORRECT SPACING
BETWEEN LUGS.
1.
2.
3.
TV / MONITOR
1" CONDUIT TO ACCESSIBLE CEILING
A/V AND DATA JUNCTION
COORDINATE EXACT HEIGHT
WITH ARCHITECTURAL
PLANS AND SECTIONS
PRIOR TO ROUGH-IN.
FINISHED FLOOR
LABEL
1 1/2" EMT CONDUIT
STUBBED TO THE
NEAREST J-HOOK
AND GROMMET
BLDG # - SECTION # - FLOOR # - JACKID #
MON
CAT6 DATA CABLE
CAT6 DATA CABLE
CAT6 DATA CABLE
CAT6 DATA CABLE
ORANGE FOR DATA
ORANGE FOR DATA
ORANGE FOR DATA
ORANGE FOR DATA
CAT6A DATA CABLE WITH ORANGE KEYSTONE
CAT6A DATA CABLE WITH ORANGE KEYSTONE
CAT6A VOICE CABLE WITH ORANGE KEYSTONE
CAT6A DATA CABLE WITH ORANGE KEYSTONE
CMON
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:3
A
M
06-13-2023
626A4-19-101
T-TJ-07
AE RENOVATE WARD 1BTECHNOLOGY - DETAILS
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
No Scale
WALL MOUNTED OUTLET - FOUR PORT FACEPLATE 1
No Scale
WIRELESS ACCESS POINT (COILED IN CEILING) 2
No Scale
GROUND BUSBAR (TYPICAL FOR ALL TR'S) 3
No Scale
TV DETAIL 4
No Scale
WALL MOUNTED OUTLET - MON / CMON 5
FIRST FLOOR
SECOND FLOOR
EXISTING MDF
BUILDING 1
ROOM 129C
THIRD FLOOR
COMM
B1-314
DATA
B1-316
BUILDING 1
ROOM G44A
(12) STRANDS OF SINGLE MODE FIBER,
(24) STRANDS OF MULTI MODE FIBER
(12) STRANDS OF SINGLE MODE FIBER,
(24) STRANDS OF MULTI MODE FIBER,
50 PAIR COPPER
(12) STRANDS OF SINGLE MODE FIBER,
(24) STRANDS OF MULTI MODE FIBER,
50 PAIR COPPER
EXISTING RISER ROOM
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-T E
C H
-V A
M C
W a rd
B
R ja c o b .k e ls h e im e r.
rv t
/1
/2
:3
:3
A
M
06-13-2023
626A4-19-101
T-TJ-08
AE RENOVATE WARD 1BTECHNOLOGY - RISER
JAK
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3" = 1'-0"
RISER
| GI 05-01 - PHASING PLANS |
| T-TJ-00 - GENERAL TECHNOLOGY INFORMATION |
| T-TD-01 - PARTIAL THIRD FLOOR PLAN - PART A - TECHNOLOGY DEMO |
| T-TD-02 - PARTIAL THIRD FLOOR PLAN - PART B - TECHNOLOGY DEMO |
| T-TD-03 - PARTIAL THIRD FLOOR PLAN - PART C - TECHNOLOGY DEMO |
| T-TJ-01 - PARTIAL THIRD FLOOR PLAN - PART A - TECHNOLOGY NEW WORK |
| T-TJ-02 - PARTIAL THIRD FLOOR PLAN - PART B - TECHNOLOGY NEW WORK |
| T-TJ-03 - PARTIAL THIRD FLOOR PLAN - PART C - TECHNOLOGY NEW WORK |
| T-TJ-04 - TECHNOLOGY - ENLARGED ROOMS |
| T-TJ-06 - TECHNOLOGY - DETAILS |
| T-TJ-07 - TECHNOLOGY - DETAILS |
| T-TJ-08 - TECHNOLOGY - RISER |
File details come from the government source that posted it. Updated .