GI 02-01 - THIRD FLOOR LIFE SAFETY PLAN - OVERALL.pdf

PDF 2 MB Posted

Attached to
Z2DA--626A4-19-101 - Renovate Ward 1B at the Alvin C. York VA Medical Center, Murfreesboro, TN 37129
Solicitation number
36C24923R0114
Issued by

About this file

This life safety plan details requirements for renovating the third floor of Ward 1B at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The renovation work includes upgrading existing partitions and barriers to the rated levels indicated, properly installing penetrations through fire-rated walls, and identifying all fire and smoke barriers in accordance with the notes and details provided. The related federal contract opportunity is solicitation number 36C24923R0114 for project 626A4-19-101 to renovate Ward 1B at the specified VA medical center. The solicitation is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9.

View the file

Other files

File Type Posted
36C24923R0114 0003.docx DOCX document
E-EI-01 - PARTIAL ELECTRICAL RISER DIAGRAM - DEMOLITION.pdf PDF
119437-Alvin C. York VAMC Renovate Ward 1B - Revision 1 - Electrical Narrative.pdf PDF
Government Answers to Industry Questions.pdf PDF
283100.pdf PDF
275223.pdf PDF
Bradley_GrabBar_8370-107.pdf PDF
Ward 1B - Revision 1.pdf PDF
Renovate Ward 1B Pre-Proposal Sign in Sheet - 07-06-2023.pdf PDF
E-EI-02 - PARTIAL ELECTRICAL RISER DIAGRAM - NEW WORK.pdf PDF
Bradley_GrabBar_8370-108.pdf PDF
General Decision Number TN20230187 06-30-2023 Rutherford County TN.pdf PDF
ASI 3413-25.pdf PDF
36C24923R0114 0002.docx DOCX document
GAMCO 125SwingUpTP.pdf PDF
Interior Wall Type Legend.pdf PDF
SUBCONTRACTOR INFORMATION AND CONSENT FORM.docx DOCX document
36C24923R0114 0001.docx DOCX document
MECH BINDER.pdf PDF
Ward 1B - Specs - Vol. 2.pdf PDF
GD Number TN20230187 05-12-2023.pdf PDF
GI 01-02 - CONSTRUCTION STAGING PLAN.pdf PDF
GI 03-01 - SECOND FLOOR ICRA PLAN.pdf PDF
GI 05-01 - PHASING PLANS.pdf PDF
GI 00-01 - COVER SHEET.pdf PDF
GI 01-10 - WALL TYPE DETAILS.pdf PDF
Price Schedule Project 626A4-19-101 Renovate Ward 1B.xlsx XLSX spreadsheet
GI 04-02 - LEAD PAINT AND TRANSITE PANELS.pdf PDF
36C24923R0114.docx DOCX document
General Conditions Breakout.xlsx XLSX spreadsheet
WARD 1B - ARCH BINDER.pdf PDF
GI 01-20 - ACCESSIBILITY DETAILS.pdf PDF
RFI Form.docx DOCX document
GI 04-01 - ACM DUCT WORK AND ACM PIPE INSULATION.pdf PDF
Performance Relevancy Survey Form - 626A4-19-101 Renovate Ward 1B.docx DOCX document
Ward 1B - Specs - Vol. 1.pdf PDF
VN 01-00 - PATIENT LIFT VENDOR DRAWINGS.pdf PDF
ELECTRICAL BINDER.pdf PDF
PLUMBING BINDER.pdf PDF
GI 01-01 - GENERAL DATA.pdf PDF
TECH BINDER.pdf PDF
WARD 1B - GENERAL.pdf PDF
WARD 1B - INTERIORS .pdf PDF
Calculation of Self Performed Work.docx DOCX document
AD 01-01 - THIRD FLOOR DEMOLITION PLAN - OVERALL.pdf PDF
Contractor EMR Certification Form.docx DOCX document
FP BINDER.pdf PDF
GI 03-02 - THIRD FLOOR ICRA PLAN.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F E

C

F E

C

FEC FEC

FEC

FEC

F E

C

FEC FEC

F E

C

F E

C

CG

C G

C G

CG

C G

CG

CG

CG

CG

CG

CG

C G

CG

C

GC

G

CG C

G

C G

CG

CG

CG

CG

CG

CG

CG

C G

C G

C G

C=18015'-0"

POINT OF EGRESS

TRAVEL DISTANCE

POINT OF DECISION

FIRE EXTINGUISHER CABINET

EGRESS CAPACITY (EXIT WIDTH/.2)

LINE OF TRAVEL

FEC

EXIT EXIT LOCATION

ROOM NAME

ROOM #

ROOM TAG

LIFE SAFETY LEGEND

EXIT SIGN (SINGLE SIDED)

EXIT SIGN WITH DIRECTIONAL ARROW

T

O E

X

IT

T

O S

M O

K E

B A

R R

IE

R

147' - 6" TO SMOKE BARRIER

T

O E

X

IT

ISO ROOM

B321

PAT. TLT.

B321B

PRIVATE ROOM

B322

PRIVATE ROOM

B315

BARI PRIVATE

ROOM

B313

BARIATRIC

PATIENT TOILET

B313A

PANTRY

B338A

SERVING

KITCHEN

B338

DINING/DAY

ROOM

B337

LAUNDRY

B359

CLEAN SUPPLY

B363

RETHERM

B361

CHUTE

B360

EQUIP STORAGE

B301

INPATIENT

REHAB

B303

STAFF LOUNGE

B304

STAFF LOCKERS

B304B

CHAIR ALCOVE

B305

FAM. LOUNGE

B307

CONSULT

B310

FAM/PUB. TLT.

B308

REC.THR. STOR.

B309

TEAM ROOM

B332

DATA

B335

CLEAN LINEN

B318

NOURISH

B312

ST. TLT.

B311A

HAC.

B325

SOILED HOLD

B327

ELEC.

B326

CLEAN UTILITY

B320

HAC

B357

WOUND CART

STOR.

B311B

SUB NS.

B358

PRIVATE ROOM

B349

ISO ROOM

B347

CLEAN UTILITY

B346

ELEC.

B344

EQUIP STOR.

B343

CLEAN LINEN

B351

SOILED HOLD

B352

BARI PRIVATE

ROOM

B355

BARI. TLT.

B355A

NOURISHMENT

B356

STAFF TLT.

B358A

PAT. TLT.

B322A

PRIVATE ROOM

B314

PAT. TLT.

B331A

PRIVATE ROOM

B330

PRIVATE ROOM

B331

PRIVATE ROOM

B348

PAT. TLT.

B330A

TEAM WORK

ROOM

B329

SUB N.S.

B311

CHARGE NURSE

B336A

NURSE STATION

B336

SOCIAL WORKER

B302

DIRTY

B362

EMPTY CYL.

STOR.

B317

FULL CYL. STOR.

B316

ANTE

B347A

NURSE

MANAGER

B333

PAT. TLT.

B315A

PAT. TLT.

B314A

ANTE

B321A

T

O S

M O

K E

B A

R R

IE

R

T

O E

X

IT

147' - 6" TO SMOKE BARRIER

T

O E

X

IT

EXIT EXIT

85' - 6" TO EXIT

EXIT

TEAM WORK

B341

CORRIDOR

B370

COMM

B334

MEDS

B336B

CHASE

CHASE

87' - 0" COMMON PATH OF TRAVEL

C

O M

M O

N P

A T

H O

F T

R A

V E

L

C

O M

M O

N P

A T

H O

F T

R A

V E

L

C

O M

M O

N P

A T

H O

F T

R A

V E

L

DN DN

DN UP

CHASE

T

O S

M O

K E

B A

R R

IE

R

297' - 6" TO EXIT

SC LEGEND

SC 2-1

SC 2-2

SC 2-3

5,389 SF

SC 2-2

7,229 SF

SC 2-37,357 SF

SC 2-1

WALL LEGEND

NOTE: REF. SHEET G01.10 OR WALL TYPE DETAILS

NON-RATED PARTITION

1-HR. RATED FIRE BARRIER

SMOKE BARRIER (1-HR. RATED)

2-HR. RATED EXISTING FIRE BARRIER

NON-RATED SMOKE PARTITION

1-HR. RATED FIRE/SMOKE BARRIER

2-HR. RATED FIRE/SMOKE BARRIER

1 HR SHAFT WALL

OCCUPANCY LOAD FACTORS

SLEEPING AREAS (120 GSF/OCCUPANT)

BUSINESS (100 GSF/OCCUPANT)

4,901 SF / 100 = 50 OCCUPANTS

13,666 SF / 120 = 114 OCCUPANTS

TOTAL EXIT CAPICITY

SLEEPING AREAS (120 GSF/OCCUPANT)

BUSINESS (100 GSF/OCCUPANT) -

1 @ 32" = (1)(32)/.2 =

TOTAL EXIT CAPICITY = 160

2 @ 32" = (2)(32)/.2 =

TOTAL EXIT CAPICITY = 320

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2019

TLC No.:

www.tlc-engineers.com

118626

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C U s e rs \a tr a y lo r\ D o c u m e n ts

\M b o ro V

A W a rd b

R e n o a tr a y lo r2 X

N D

H .r v t

/1

/2

:2

:5

P

M

04-14-2023

626A4-19-101

GI 02.01

AE RENOVATE WARD 1B

THIRD FLOOR LIFE SAFETY PLAN -

OVERALL

MC/AT

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

4. REMOVE EXISTING ANNEALED OR OTHERWISE NON-SAFETY-RATED GLASS FROM EXISTING DOORS, SIDELIGHTS, AND OTHER HAZARDOUS LOCATIONS SCHEDULED TO REMAIN WITHIN PROJECT AREA. IN NON-RATED OPENINGS, PROVIDE NEW TEMPERED GLASS TO MATCH ORIGINAL DESIGN. IN RATED OPENINGS, PROVIDE NEW IMPACT-RESISTANT, FIRE-RATED GLASS TO MATCH ORIGINAL CONFIGURATION, RATED NO LESS THAN

SURROUNDING WALL CONSTRUCTION.

3. EXIT PATHS SHALL BE MAINTAINED CLEAR OF EQUIPMENT, MATERIALS AND DEBRIS AND SHALL BE MARKED WITH

APPROVED EXIT SIGNS VISIBLE AT ALL TIMES.

2. TEMPORARY PARTITIONS REQ'D FOR DUST OR INFECTION CONTROL SHALL BE CONSTRUCTED TO MAINTAIN EXISTING FIRE BARRIER REQUIREMENTS. WHERE TEMPORARY PARTITIONS MUST INCLUDE DOORS FOR CONSTRUCTION ACCESS OR LIFE SAFETY EGRESS, INSTALL DOOR ASSEMBLIES EQUAL IN RATING TO THE CONSTRUCTION BEING PENETRATED WITH POSITIVE LATCHING HARDWARE AND EXIT DEVICES (PANIC BARS)

WHERE REQ'D.

1. ALL EXISTING PARTITIONS INDICATED TO REMAIN SHALL BE UPGRADED TO RATING NOTED IF THEY OCCUR ON OR IN A SMOKE COMPARTMENT WITHIN CONSTRUCTION AREA. EXTENT OF UPGRADE SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, EXTENDING PARTITIONS TO UNDERSIDE OF DECK, INSTALLING BLOW-OUT PATCHES, RECONSTRUCTING INTERSECTIONS AT OTHER PARTITIONS, INSTALLING UL APPROVED FIRESTOP SYSTEM AT WALL PENETRATIONS, RE-INSTALLING FIRE AND/OR FIRE/SMOKE DAMPERS, INSTALLING FIVE-SIDED ENCLOSURES OF RECESSED ITEMS, INSTALLING ADDITIONAL FRAMING, AND INSTALLING 12” WIDE STRIPS OF G.W.B OVER JOINTS NOT OFFSET FROM OPPOSING SIDE. AT CONTRACTOR'S OPTION, PARTITION MAY BE COMPLETELY STRIPPED AND REBUILT. ALL SERVICES WITHIN PARTITION MUST BE MAINTAINED AND FINISHES

RESTORED REGARDLESS OF COURSE OF ACTION.

RENOVATION WORK

15. REFER TO THE CONTRACT DOCUMENTS FOR ADDITIONAL INFORMATION RELATED TO LIFE SAFETY

CONSTRUCTION AND APPROVED UL ASSEMBLIES.

● PROVIDE WET-CHEMICAL TYPE, CLASS K WALL-HUNG FIRE EXTINGUISHERS THROUGHOUT KITCHENS.

LOCATE SO THAT A MINIMUM OF 10 FEET AND A MAXIMUM OF 20 FEET OF TRAVEL FROM ANY PIECE OF

COOKING EQUIPMENT BELOW HOOD WILL BE PROVIDED.

● PROVIDE CLEAN AGENT TYPE FIRE EXTINGUISHERS WITH UL RATING OF 1A:10B:C IN EACH DATA CENTER, MRI ROOM, AND MRI CONTROL ROOM. LOCATE SO THAT A MAXIMUM OF 75 FEET OF TRAVEL FROM ANY

SPACE WILL BE PROVIDED.

● PROVIDE DRY CHEMICAL, ABC TYPE FIRE EXTINGUISHERS WITH UL RATING OF 4A:60B:C IN ALL

MECHANICAL SPACES.

● PROVIDE MULTI-PURPOSE, DRY CHEMICAL, ABC TYPE FIRE EXTINGUISHERS WITH UL RATING OF 4A:60B:C THROUGHOUT THE ENTIRE BUILDING. LOCATE SO THAT A MAXIMUM OF 75 FEET OF TRAVEL FROM ANY

SPACE WILL BE PROVIDED.

14. FIRE EXTINGUISHER LOCATIONS: PROVIDE AS SHOWN ON PLANS AND AS INDICATED, WHICHEVER IS MORE

RESTRICTIVE. CABINETS SHALL BE FULLY RECESSED (U.N.O.):

13. DOORS, WINDOWS, AND OTHER OPENINGS SHALL BE RATED EQUAL TO THAT OF THE CONSTRUCTION BEING PENETRATED. PROVIDE POSITIVE LATCHING AT RATED DOOR ASSEMBLIES. GLAZING SHALL BE FIRE RATED EQUAL TO THE WALL CONSTRUCTION AND INSTALLED IN AN EQUALLY RATED FRAMING SYSTEM, TESTED AS AN

ASSEMBLY. WIRE GLASS IS NOT PERMITTED.

12. WHERE FIRE RATED WALL ASSEMBLIES OCCUR IN PROXIMITY TO STEEL BEAMS OR JOINTS WITH INADEQUATE DIMENSION TO INSTALL SCREWS, PROVIDE STUD FRAMING AROUND THE BEAM OR JOIST IN ACCORDANCE WITH U.L. DESIGN N-501 WITH LAYERS OF G.W.B. EQUAL IN NUMBER TO THE WALL ASSEMBLY CONSTRUCTION.

11. WHERE PARTITIONS MUST BE CONNECTED TO STRUCTURE FOR SUPPORT, INSTALL 20 GUAGE GALVANIZED METAL Z-CLIPS SPACED AS REQ'D, BUT NOT MORE THAN 2'-0” O.C. PRIOR TO APPLICATION OF FIREPROOFING.

10. WHERE DEVICES, CABINETS, OR ACCESSORIES GREATER THAN 16 SQ. IN. ARE INDICATED IN RATED CONSTRUCTION, PROVIDE A FIVE-SIDED G.W.B. ENCLOSURE CONSTRUCTED OF LAYERS OF G.W.B. EQUAL IN

NUMBER TO THE CONSTRUCTION BEING PENETRATED.

9. WHERE DEVICES ARE INDICATED IN RATED CONSTRUCTION, THE MAXIMUM ALLOWABLE AREA OF INDIVIDUAL U.L.

LISTED BACKBOXES PERMITTED IN THE WALL IS 16 SQ. IN. WITH MAXIMUM AGGREGATE AREA OF 100 SQ. IN PER 100 SF OF WALL AREA. BACKBOXES ON OPPOSITE FACES OF RATED WALLS SHALL BE OFFSET A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. WHEN PENETRATIONS EXCEED THE ALLOWABLE AREAS, DEVICES SHALL BE PROVIDED WITH A FIVE-SIDED G.W.B. ENCLOSURE OR UL LISTED INTUMESCENT FIRE PUTTY.

8. PROVIDE ENCLOSURE AND ACCESS PANEL AT EACH FIRE PROTECTION INSPECTION TEST VALVE. DO NOT LOCATE VALVES AND PIPES IN EXTERIOR WALLS. PROVIDE PAINTED STEEL ACCESS PANELS IN WALLS &

CEILINGS EQUAL IN RATING TO THE CONSTRUCTION BEING INSTALLED IN.

7. INSTALL METALLIC SLEEVES AROUND LOW VOLTAGE CABLES THAT PENETRATE THE WALL, AND SEAL AROUND

THE SLEEVE AND INSIDE THE SLEEVE WITH AN APPROVED SEALANT.

6. INSTALL G.W.B. TIGHT TO ALL DUCTS AND DUCT INSULATION. USE METALLIC DUCT TAPE TO SEAL BETWEEN THE

DUCT AND THE G.W.B.

● WHERE THE DIAMETER OF THE OPENING IS GREATER THAN 3”, THE BLOW-OUT PATCH SHALL EXTEND A MINIMUM OF 6” ABOVE AND BELOW THE OPENING AND A MINIMUM OF 3” BEYOND THE STUDS ON BOTH SIDES OF THE OPENING. RUNNER CHANNELS SHALL BE SECURED TO THE STUDS ABOVE AND BELOW THE OPENING. THE PATCHES SHALL BE FASTENED TO THE STUDS & CHANNELS A MINIMUM OF 3” FROM

THE EDGES OF THE PATCH WITH JOINT COMPOUND APPLIED TO THE BACKSIDE OF THE PATCH.

● WHERE THE DIAMETER OF THE OPENING IS LESS THAN 3”, THE BLOW-OUT PATCH SHALL EXTEND A MINIMUM OF 6” BEYOND THE OPENING IN ALL DIRECTIONS. THE PATCH SHALL BE FASTENED NOT LESS THAN 3” FROM THE EDGE OF THE PATCH WITH JOINT COMPOUND APPLIED TO THE BACKSIDE OF THE

PATCH.

5. INSTALL BLOW-OUT PATCHES MADE OF LAYERS OF G.W.B. EQUAL TO THAT OF THE PARTITION CONSTRUCTION, CUT TO FIT TIGHT TO PENETRATIONS, IN INSTANCES WHERE THE ANNULAR OPENING EXCEED THAT ALLOWED BY THE UL ASSEMBLY. DO NOT APPLY JOINT COMPOUND OVER SCREWS AT PATCHES. DO NOT REMOVE EXCESS

COMPOUND FROM EDGES OF PATCH AFTER PLACEMENT.

4. FIRESTOP ALL INTERUPTIONS TO FIRE RATED ASSEMBLIES, MATERIALS, AND COMPONENTS WITH MATERIALS WHICH HAVE BEEN TESTED ACCORDING TO ASTM E814, UL 1479, OR UL 2079 TO PROVIDE A FIRE RATING AND

SMOKE RATING EQUAL TO THAT OF CONSTRUCTION BEING PENETRATED.

AT DOUBLE LAYER G.W.B APPLICATIONS, SECURE SECOND LAYER TO FIRST WITH FASTENERS (DO NOT USE ADHESIVES). PLACE SECOND LAYER PERPENDICULAR TO FIRST LAYER. OFFSET JOINTS OF SECOND LAYER FROM JOINTS OF FIRST LAYER. FINISH JOINTS FULL HEIGHT OF WALL WITH TAPE & COMPOUND PER

SPECIFICATIONS

● SCREWS WITHIN THE FIELD OF THE BOARD SHALL NOT EXCEED 12” O.C. FASTENED TO SOLID FRAMING.

● ALL EDGES OF BOARD SHALL BE SCREWED NOT MORE THAN 8” O.C. TO SOLID FRAMING.

USE TYPE S OR S12 FASTENERS INSTALLED IN ACCORDANCE WITH APPLICABLE FIRE TEST, BUT NO LESS THAN

AS FOLLOWS:

● HORIZONTAL JOINTS OFFSET 24” VERTICALLY. HORIZONTAL JOINTS SHALL NOT OCCUR BELOW CEILING.

● VERTICAL JOINTS OFFSET 16” HORIZONTALLY

3. ALL G.W.B. SHALL BE 5/8" TYPE 'X' U.N.O. STAGGER JOINTS ON OPPOSITE SIDES OF PARTITIONS AS FOLLOWS:

7) NON-RATED PARTITIONS

6) NON-RATED SMOKETIGHT PARTITIONS

5) 1-HR FIRE (CORRIDORS WHERE REQ'D)

4) 1-HR FIRE (HAZARDOUS LOCATIONS)

3) 1-HR FIRE/SMOKE

2) 2-HR FIRE

1) 2-HR FIRE/SMOKE

2. ALL RATED BARRIERS SHALL EXTEND THROUGH THE INT. LAYER OF GYP. BD. & STUD CAVITY TIGHT TO THE BACK OF EXT SHEATHING IN EXT WALLS & OVERHANGING FASCIAS. WHERE SUCH PARTITIONS INTERSECT ONE OF LESSER FIRE RATING, THEIR LAYERS OF G.W.B. SHALL CONTINUE UNINTERRUPTED THROUGH THE WALL OF LESS

FIRE RATING. THE FOLLOWING WALL PRIORITIES SHALL BE OBSERVED:

● USE SEMI-GLOSS PAINT

● LOCATE NOT MORE THAN 12'-0" O.C. ON CORRIDOR SIDES OF PARTITIONS, AND WITH A LEAST ONE MESSAGE PER ROOM ON ROOM SIDE OF PARTITION, AND WITHIN 15'-0" OF THE END OF EACH WALL.

● STENCIL MESSAGE SIMILAR TO: "SMOKE PARTITION" OR "1-HR FIRE BARRIER."

● IDENTIFY PARTITIONS ABOVE CEILINGS ON BOTH SIDES OF PARTITIONS EXCEPT WITHIN SHAFTS IN RED

LETTERS NOT LESS THAN 4" HIGH WITH AT LEAST A 3/8" STROKE.

1. FIRE AND SMOKE PARTITION / BARRIER IDENTIFICATION:

ALL WORK

2. THE CONTRACTOR SHALL AT ALL TIMES ENDEAVOR TO CONSTRUCT THE FACILITY IN STRICTEST ACCORDANCE TO SOUND PRACTICES OF FIRE RESISTIVE CONSTRUCTION. DEVIATIONS FROM MFG RECOMMENDATIONS, INDEPENDENT FIRE TESTS, OR UL ASSEMBLY REQUIREMENTS SHALL BE CORRECTED AT NO ADDITIONAL COST.

1. DETAILS AND NOTES ABOUT RATED WALLS AND RATED PENETRATIONS ARE PROVIDED IN CASE CONTRACTOR COMES ACROSS A SITUATION WHERE THEY ARE NEEDED. SOME OF THE RATED WALL AND PENETRATION NOTES

MAY NOT APPLY TO THIS PROJECT. CONTACT THE COR IF QUESTIONS ARISE.

GENERAL

GENERAL LIFE SAFETY NOTES

NOTE: THIS DRAWING MUST BE

PRINTED IN COLOR TO REPRODUCE

ALL FIRE RATED WALL SYMBOLS.

3/32" = 1'-0"

1 WARD 1B - LIFE SAFETY PLAN

NOT TO SCALE

2 THIRD FLOOR SMOKE COMPARTMENT PLAN

0 5' 10'

LIFE SAFETY - DEAD END CORRIDOR EXEMPTION

No. Date Description

Sheets
GI 02.01 - THIRD FLOOR LIFE SAFETY PLAN - OVERALL

File details come from the government source that posted it. Updated .