This document provides details on a federal contract opportunity for plumbing services. The solicitation number is 36C24923R0114 and seeks bids to renovate Ward 1B at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The opportunity type is a solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The 14MB PLUMBING BINDER.pdf file contains further specifications on the plumbing services required for the renovation project at the specified VA medical center location. Bids are due by the date listed on the Solicitation Number for the contract to renovate Ward 1B and provide plumbing services.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLEAN UTILITY
SOILED UT.
PT. ROOM
PT. ROOM
PT. ROOM
PT. ROOM
ELEC.
STAFF TLT.STAIR
PT. ISO ROOM
PT. ROOM
PT. ROOM
WORK RM
ANTE
OFFICE
RESIDENTS RM.
MECH.
PT. ROOM
PT. ROOM
STOR. ROOM MEDS
SUPPLY ROOM
ELEC.
NOURISHMENT
CHUTE
IT
COMM
CONSULT
PT. ROOM PT. ROOM
PT. ROOM
PT. ROOM
MECH
OFFICE
RESIDENTS
ROOM
STAIR
PT. ROOM
PT. ROOM
PT. ROOM
WORK ROOM
CLEAN UTILITY
SOILED UTILITY
PT. ROOM
PT. ROOM
PT. ROOM
PT. ROOM
HAC ELEC.
STAFF TLT
NURSE WK.
NURSE STATION
SOCIAL WORK
WAITING ROOM
STAIRS
CHASE
LOCKER RM.
RETHERM
CONF.
STAFF TLT.
CORRID
STAFF BREAK
EXAMPLE #1
EXAMPLE LEGEND
EXAMPLE #2
EXAMPLE #3
EXAMPLE #4
EXAMPLE #5
EXAMPLE #6
ISO ROOM
PAT. TLT.
PRIVATE ROOM
PRIVATE ROOM
PRIVATE ROOM
BARI PRIVATE
ROOM
BARIATRIC
PATIENT TOILET
PRIVATE ROOM
PRIVATE ROOM
PANTRY
SERVING
KITCHEN
DINING/DAY
ROOM
LAUNDRY CLEAN SUPPLY
RETHERMCHUTE
EQUIP STORAGE
INPATIENT
REHAB
STAFF LOUNGE
STAFF LOCKERS
CHAIR ALCOVE
FAM. LOUNGE
CONSULT
FAM/PUB. TLT.
REC.THR. STOR.
TEAM ROOM
DATA
CLEAN LINEN
NOURISH
ST. TLT.
HAC.
SOILED HOLD
ELEC.
CLEAN UTILITY
HAC
WOUND CART
STOR.SUB NS.
PRIVATE ROOM
PRIVATE ROOM
ISO ROOM
CLEAN UTILITY
PAT. TLT.
ELEC.
EQUIP STOR.
TEAM WORKCLEAN LINEN
SOILED HOLD
BARI PRIVATE
ROOM
BARI. TLT.
NOURISHMENT
PAT. TLT.
PAT. TLT.
STAFF TLT.
PRIVATE ROOM
PAT. TLT.
PAT. TLT.
PAT. TLT.
PRIVATE ROOM
PAT. TLT.
PRIVATE ROOM
PRIVATE ROOM
PRIVATE ROOM
PAT. TLT.
PAT. TLT.
PAT. TLT.
PAT. TLT.
TEAM WORK
ROOM
SUB N.S.
CHARGE NURSE
NURSE STATION
SOCIAL WORKER
DIRTY
EMPTY CYL.
STOR.
FULL CYL. STOR.
ANTE
NURSE
MANAGER
PAT. TLT.
PAT. TLT.
ANTE
MEDS
COMM
STAFF TLT.
PRIVATE ROOM PRIVATE ROOM
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
VENDING
PAT. TLT.
PAT. TLT.
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STAIR 1
STAIR 2
STAIR 3
EXISTING RISER
ELEV.
ELEV.
CHASE
CHASE
CHASE
CHASE
THE INTENT WITH THIS PLAN IS TO SHOW
HOW THE AREAS BETWEEN THE SECOND
FLOOR AND THRID FLOOR ALIGN
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2019
TLC No.:
www.tlc-engineers.com
118626
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C U s e rs \a tr a y lo r\ D o c u m e n ts
\M b o ro V
A W a rd b
R e n o a tr a y lo r2 X
N D
H .r v t
/1
/2
:5
:4
P
M
04-14-2023
626A4-19-101
GI 05.01
AE RENOVATE WARD 1BPHASING PLANS
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 SECOND FLOOR PLAN - PHASING PLAN
0 8' 16' 32'4'
2 03 THIRD FLOOR PLAN - PHASING PLAN
0 8' 16' 32'4'
GENERAL NOTE:
1. THE PHASING PLAN IS NOTED AS EXAMPLES TO GIVE THE CONTRACTOR AN
UNDERSTANDING OF HOW THE PHASING FOR THE PROJECT NEEDS TO BE
ADDRESSED. WHILE THEY ARE LISTED BY NUMBER THESE EXAMPLES CAN BE
CONDUCTED IN ANY SEQUENCE AS DEEMED NECESSARY FOR THE MOST EFFECIENT
PROCESS POSSIBLE.
2. IN GENERAL 5 PATIENT ROOMS AT ONE TIME ON THE FLOOR BELOW WILL BE ABLE
TO BE TEMPORARLY OUT OF COMMISSION TO WORK ON VERTICAL SERVICES, THERE
MUST BE AT LEAST 15 ACTIVE PATIENT ROOMS AT ALL TIMES.
3. ALL ROOMS THAT ARE BEING WORKED ON SHALL BE PROTECTED FROM DAMAGE
AS BEST AS POSSIBILE. MOST OF THE WORK WILL TAKE PLACE IN THE CEILING,
HOWEVER DAMAGE TO ANY OTHER PART OF THE ROOM MUST BE REPARIED.
PROTECT EXISTING CEILING TILES, TILES THAT ARE DAMAGED OR BROKEN MUST BE
REPLACED TO THE ORIGINAL STATE.
4. CAREFUL COORDINATION WITH THE FACILITY MUST TAKE PLACE TO ADDRESS ANY
SHUTDOWNS THAT COULD EFFECT AREAS OUTSIDE OF THE DESIGNATED EXAMLE
ZONE.
5. IF SUPPORT SPACE INSIDE OF A DESIGNATED EXAMPLE ZONE IS SERVING
ANOTHER EXAMPLE ZONE COORDINATE SPECIFIC TIMES WITH THE FACILITY TO GAIN
ACCESS TO THIS SPACE.
6. ICRA BARRIERS MUST BE USED TO CLOSE OFF EACH AREA THAT IS BEING WORKED
ON TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM INFILTRATING OCCUPIED
SPACE. BARRIERS SHALL BE INSTALLED AND SEALED ALONG WITH STICKY MATS AND
ANY OTHER INFECTION CONTROL ITEMS. IN SOME INSTANCES ICRA BARRIERS MAY
BE REQUIRED PER ROOM.
7. WORK IN THE CONNECTING CORRIDORS, ELEVATOR LOBBY AND NURSE STATION
SHALL BE CAREFULLY COORDINATED WITH THE FACILITY AND STAFF. THE NEED TO
WORK IN THESE AREAS SHALL BE EVALUATED ON A AS NEEDED BASIS. ELEVATOR
ACCESS SHALL BE MAINTAINED AT ALL TIMES
No. Date Description jim.elder Rectangle jim.elder Typewritten Text 06-13-2023 jim.elder Rectangle jim.elder Snapshot jim.elder Rectangle jim.elder Snapshot
FDFD
- BALL VALVE (SHUT-OFF VALVE)
- DIRECTION OF FLOW
- REDUCED PRESSURE BACKFLOW PREVENTER
- DOMESTIC COLD WATER
- DOMESTIC HOT WATER
- FUEL OIL FILL
- BELOW GROUND SANITARY
- FLOOR CLEAN OUT
- FLOOR DRAIN
- CALIBRATED BALANCING VALVE (BV)
- CHECK VALVE (SWING)
- RELIEF OR SAFETY VALVE
- PRESSURE REDUCING VALVE
- SOLENOID OPERATED VALVE
- ABOVE GROUND SANITARY
- DENTAL AIR
CO
1 - REVISION REFERENCE
- DETAIL REFERENCE: TOP-DETAIL#,
BOTTOM-DRAWING# SHOWN ON
- DOMESTIC HOT WATER RETURN
PLUMBING DRAWING INDEX
REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION
STANDARDS.
UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW
SURVEYS, AS-BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS
PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON
DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS
DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY.
FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, WHICH
ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF THE NEW
WORK.
NOTIFY OWNER AT LEAST 72 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE.
SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES.
SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON-NORMAL CONTRACTOR
WORKING HOURS. CONTRACTOR TO PRODUCE COORDINATION DRAWINGS AND
SCHEDULES. THIS MAY REQUIRE NIGHT AND OR WEEKEND WORK SCHEDULES.
PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS
NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY
ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO
MAINTAIN CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL
INSTALLATIONS AND OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID
INTERFERENCES.
PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES.
CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL
ROOMS OR AS SPECIFICALLY NOTED.
PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE NON-
ACCESSIBLE CEILINGS.
SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND
FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR
EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS
FOR FINAL FINISHES.
FLASH AND COUNTER-FLASH ROOF PENETRATIONS. SEE ARCHITECTURAL DRAWINGS
FOR DETAILS.
WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS
WITH ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER.
PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUM CLEARANCE
BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR.
SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS.
PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES,
DEVICES, APPLIANCES AND APPARATUS.
ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED.
MOUNT HOSE BIBBS 24" ABOVE FINISHED GRADE, UNLESS OTHERWISE NOTED.
PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL
CLEANOUT WITH COVER FLUSH TO FINISH SURFACE.
COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET
FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN.
COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS,
ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL
PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE RE-
ROUTED AT NO ADDITIONAL COST.
ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER
DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE
FIXTURE.
PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH-IN AND MAKE FINAL
CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES,
TRAPS, ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY
THIS CONTRACTOR OR FURNISHED BY OTHERS.
INSTALL LOOP (FLEX) EXPANSION JOINT FOR DOMESTIC WATER SYSTEMS. SEE VA
GUIDELINES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
GENERAL NOTESPLUMBING ABBREVIATIONS
SYMBOL DESCRIPTION
- COMPRESSED AIR
- ABOVE FINISH FLOOR
- ACID WASTE
- ACID VENT
- BALANCING VALVE
- CATCH BASIN
- CONDENSATE DRAIN
- CUBIC FEET PER HOUR
- CLEANOUT
- CONTINUATION
- DOMESTIC COLD WATER
- DEIONIZED WATER
- DOWN
- DOWNSPOUT
- DRAWING
- EXISTING
- DEGREE FAHRENHEIT
- FLOOR CLEANOUT
- FLOOR DRAIN
- FUEL OIL FILL
- FUEL OIL GAGE
- FUEL OIL RETURN
- FUEL OIL SUPPLY
- FUEL OIL VENT
- FLOOR SINK
- GAS
- GALLONS PER HOUR
- GALLONS PER MINUTE
- KITCHEN WASTE (GREASE)
- HOSE BIBB
- HUB DRAIN
- DOMESTIC HOT WATER
- DOMESTIC HOT WATER RECIRCULATING
- INVERT ELEVATION
- INDIRECT WASTE
- KILOWATT
- POUNDS
-MEDICAL AIR
-MEDICAL VACUUM
- MANHOLE
-NITROGEN
-NITROUS OXIDE
- NORMALLY CLOSED
- NOT IN CONTRACT
- NORMALLY OPEN
- NON-POTABLE WATER
- NOT TO SCALE
- OUTSIDE DIAMETER
-OXYGEN
- PRESSURE REDUCING VALVE
- POUNDS PER SQUARE INCH
- POLYVINYL CHLORIDE PIPE
- ROOF DRAIN
- REDUCED PRESSURE BACKFLOW PREVENTOR
- SANITARY
- STORM DRAIN
- SQUARE FEET
- SHEET
- STORM
- OVERFLOW STORM DRAIN
- SOFT COLD WATER
- VENT
- VACUUM
- VACUUM CLEANING
- VENT THRU ROOF
- WALL CLEANOUT
- WATER
CA
AFF
AW
AV
BV
CB
CD
CFH
CO
CONT
CW
DI
DN
DS
DWG
EXIST
°F
FCO
FD
FOF
FOG
FOR
FOS
FOV
FS
G
GPH
GPM
GR
HB
HD
HW
HWR
IE
IW
KW
LBS
MA OR A
MV 0R V
MH
NI OR N
N20
NC
NIC
NO
NP
NTS
OD
OX OR O
PRV
PSI
PVC
RD
RPBP
SAN
SD
SF
SH
ST
STO
SW
V
VAC
VC
VTR
WCO
WTR
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
PLUMBING SYMBOL LEGEND
SYMBOL DESCRIPTION
P2.01
- ABOVE GROUND CONDENSATE DRAIN
- COMPRESSED AIRCA
- ACID VENTAV
- ACID WASTEAW
- BELOW GROUND ACID WASTEAW
CD
- BELOW GROUND CONDENSATE DRAINCD
DA
- DENTAL VACUUMDV
FOF
- FUEL OIL GAGEFOG
- FUEL OIL RETURNFOR
- FUEL OIL SUPPLYFOS
- DEIONIZED WATERDI
- FUEL OIL VENTFOV
- GASG
- KITCHEN WASTE (GREASE)GR
- MEDICAL COMPRESSED AIRMA
- MEDICAL VACUUMMV
- NITROGENN
- NITROUS OXIDEN20
- OXYGENOX
S
S
- SANITARY VENT
- ABOVE GROUND STORMST
- BELOW GROUND STORMST
- VACUUM (AIR)VAC
- BELOW GROUND OVERFLOW STORMSTO
- SOFT COLD WATERSW
- OVERFLOW STORM DRAINSTO
- WASTE OILWO
- WASTE OIL VENTWOV
- WATER METERM
- ROOF DRAIN
FS - FLOOR SINK
- CONNECT TO EXISTING
- DEMOLISH TO POINT INDICATED
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:0
:4
A
M
06-13-2023
626A4-19-101
P-PI-01
AE RENOVATE WARD 1BPLUMBING LEGENDS & NOTES
DRT
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
PLUMBING DRAWING INDEX
SHEET DESCRIPTION
P-PI-01 PLUMBING LEGENDS & NOTES
P-PI-02 PLUMBING SCHEDULES
P-PD-01 PARTIAL THIRD FLOOR- PART A - PLUMBING - DEMO
P-PD-02 PARTIAL THIRD FLOOR- PART B - PLUMBING - DEMO
P-PD-03 PARTIAL THIRD FLOOR- PART C - PLUMBING - DEMO
P-PD-04 PARTIAL THIRD FLOOR- PART A - MED GAS - DEMO
P-PD-05 PARTIAL THIRD FLOOR- PART B - MED GAS - DEMO
P-PD-06 PARTIAL THIRD FLOOR- PART C - MED GAS - DEMO
P-PD-07 FOURTH FLOOR - PLUMBING - DEMO
P-PP-01 PLUMBING - SECOND FLOOR ZONE PLAN
P-PP-02 PARTIAL THIRD FLOOR - PART A - GRAVITY - NEW WORK
P-PP-03 PARTIAL THIRD FLOOR - PART B - GRAVITY - NEW WORK
P-PP-04 PARTIAL THIRD FLOOR - PART C - GRAVITY - NEW WORK
P-PP-05 PARTIAL FOURTH FLOOR - PART A - GRAVITY - NEW WORK
P-PP-06 PARTIAL FOURTH FLOOR - PART B - GRAVITY - NEW WORK
P-PP-07 PARTIAL FOURTH FLOOR - PART C - GRAVITY - NEW WORK
P-PP-08 PARTIAL THIRD FLOOR - PART A - PRESSURE - NEW WORK
P-PP-09 PARTIAL THIRD FLOOR - PART B - PRESSURE - NEW WORK
P-PP-10 PARTIAL THIRD FLOOR - PART C - PRESSURE - NEW WORK
P-PG-01 PARTIAL THIRD FLOOR - PART A - MED GAS - NEW WORK
P-PG-02 PARTIAL THIRD FLOOR - PART B - MED GAS - NEW WORK
P-PG-03 PARTIAL THIRD FLOOR - PART C - MED GAS - NEW WORK
P-PW-01 PLUMBING RISERS PART A - PRESSURE
P-PW-02 PLUMBING RISERS PART B - PRESSURE
P-PW-03 PLUMBING RISERS PART C - PRESSURE
P-PW-04 PLUMBING RISERS PART A - GRAVITY
P-PW-05 PLUMBING RISERS PART B - GRAVITY
P-PW-06 PLUMBING RISERS PART C - GRAVITY
P-PI-03 PLUMBING DETAILS
P-Pl-04 PLUMBING DETAILS
GI-05.01 PHASING PLANS
No. Date Description
N/A
AMERICAN
STANDARD
PP-101
WATER CLOSET ADA - FLOOR MTD, ELONGATED,
TOP SPUD, VITREOUS CHINA 1.28GPF MANUAL, BED PAN
WASHER ASSEMBLY WITH OFFSET TUBE
AMERICAN
STANDARD
6047.821.002
MODEL DESCRIPTIONFIXTURE MFGMARK
BLDG1 PLUMBING FIXTURE SCHEDULE
FAUCET FLUSH VALVE
MFG MODEL MFG
N/A
PP-401
PP- 608
SEAT
MODEL MFG
1655SSCT BEMIS
CARRIER
MODEL MFG
STRAINER/TRAP
MODEL MFG
SUPPLIES
MODEL MFG
N/A N/A N/A
N/A N/A
N/A N/A
ZURN 1231
ZURN 1225 ELKAY
MODEL
NOTES
ELECTRIC WATER COOLER - ADA,
EZH2O BOTTLE FILLER STATION
MCGUIRE 8872
3043.001
LZS8WSSP
N/A N/A N/A
MCGUIRE LF158
INSTALL HANDLE ON WIDE SIDE OF
FIXTURE. 12" ROUGH-IN
FD-1 N/A N/A N/A N/A ZURN ZN-415-VP
N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A
N/A N/AN/A N/A
FLOOR DRAIN (FINISHED AREAS) - NICKLE BRONZE DURA-
COATED CAST IRON BODY W/ BOTTOM OUTLET. VERIFY
ROUND OR SQUARE GRATE WITH ARCHITECT
PROVIDE ELECTRONIC TRAP PRIMER
AMERICAN
STANDARD
WALL HUNG, LAVATORY 4" CENTERS ADA - WRIST BLADE
HANDLES, GOOSE NECK, 1.5GPM NON-AERATOR
T&S BRASS B-1141-CR-B0199-29 MCGUIRE 2125PW MCGUIRE LF2165LK 0355.012
PROVIDE OFFSET DRAIN & SUPPLY/TRAP
COVERS/WRAPS. CHICAGO 131-CFMABRCF
THERMOSTATIC MIXING VALVE
PP-531 N/A N/A N/A N/APROVIDED WITH
CASEWORK
SOLID SURFACE, 3-HOLE 4" CENTER ADA, WRIST BLADE
HANDLES, GOOSE NECK, 1.5GPM NON-AERATOR
SOLID
SURFACE
N/A N/A MCGUIRE MCGUIRE LF2165
STAINLESS STEEL WALL MOUNTED SERVICE SINK
23" x 18-1/2" x 12, 2-HOLE WALL FAUCET
N/A
BARIATRIC WATER CLOSET ADA - FLOOR MTD, ELONGATED,
TOP SPUD, BOTTOM OUTLET, 1.28GPF MANUAL, BED PAN
CLEANSER CHROME WITH HOOK, HOSE & VACUUM BREAKER
AMERICAN
STANDARD
N/A
HSBJ
RATED 1200LBS
BIG JOHN N/A N/A N/A N/A N/A N/A INSTALL HANDLE ON WIDE SIDE OF
FIXTURE. 12" ROUGH-IN
NOTES:
1. T&S BRASS FAUCET IS FACILITY STANDARD. RATED FOR 180 DEGREE HOT WATER.
2. PROVIDE CHICAGO 131-CFMABRCF MAX TEMP. RATING 200 DEGREES (F),THERMOSTATIC MIXING VALVES. 180 DEGREE HOT WATER
TO BE USED TO FLUSH SYSTEM IF LEGIONELLA IS DETECTED. DO NOT INSTALL WITH BRAIDED STAINLESS STEEL HOSES.
3. ACORN SHOWER VALVES IS FACILITY STANDARD.
CLEANOUTS:
1. PROVIDE ZURN ZN-1400-VP NICKLE BRONZE FLOOR CLEANOUTS OR EQUAL. REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR TYPES.
2. PROVIDE ZURN Z-1445 WALL CLEANOUTS OR EQUAL.
3. PROVIDE ZANB-1460 NICKLE BRONZE WITH SS COVER WALL ACCESS DOORS OR EQUAL.
GUY GREY
STAINLESS STEEL WASHING MACHINE
BOX W/ DRAIN. 1/2" SWEAT VALVES.
SHOWER ADA CORNER SHOWER, 60" HOSE, 30" GLIDE
RAIL, INLINE VACUUM BREAKER. GRAB
BARS,THERMOSTATIC - TEMP/PRESSURE BALANCING
MIXING SHOWER VALVE
ACORN
T&S BRASS
T&S BRASS B-2866-05CR-L15
PP-114 WHITEWHALL WH2125-A
6047.121.002 7582.167
PP- 808
BARIATRIC SHOWER ADA 72"x48", 60" HOSE, 30"
GLIDE RAIL, INLINE VACUUM BREAKER. GRAB
BARS,THERMOSTATIC - TEMP/PRESSURE
BALANCING MIXING SHOWER VALVE
ACORN
SV16LVR-HHC15-HHSH-
HHSE-QD-GR30-IVB
PP-505
PP-421
BARIATRIC ADA- SOLID SURFACE BARIATRIC SINK,
4" CENTER WITH ADA BLADES, GOOSE NECK. 1.5GPM
NON-AERATOR.
WILLOUGHBY
BHS-3123-4CC-MT
WHITE
T&S BRASS
ELKAY ESS23122
B-1141-CR-B0199-29
B-1141-CR-B0199-29 2125PW
MCGUIRE 8902 MCGUIRE LF2165LK N/A N/A N/A N/A
N/A N/A
WHITEWHALL -MC
PP- 812 GUY GREY
SSWB1
82171
SSIB1
88156
STAINLESS STEEL ICE MAKER BOX W/
QUARTER TURN VALVE
N/A N/A N/A N/AN/A N/A
N/A N/A N/A N/AN/A N/A
CHICAGO 131-CFMABRCF THERMOSTATIC
MIXING VALVE
N/A N/A N/A N/A ZURN 1218
SINK DROP-IN ADA, 22"X19-1/2"X6.5" DEEP, 3-HOLE,
ANTIMICROBIAL COPPER. GOOSE NECK W/ WRIST BLADES.
PP-529 ELKAY LRAD22195-CU MCGUIRE 8902 MCGUIRE LF2165N/A N/A N/A N/A N/A N/A
ELKAY LKVR18-CU DRAIN. CHICAGO 131-
CFMABRCF THERMOSTATIC MIXING VALVE
T&S BRASS B-2866-05CR-L15SINK DROP-IN ADA, 22"X22"X6.5" DEEP, 3-HOLE,
ANTIMICROBIAL COPPER. GOOSE NECK W/ WRIST BLADES.
PP-528 ELKAY LRAD222265-CU MCGUIRE 8902 MCGUIRE LF2165N/A N/A N/A N/A N/A N/A
ELKAY LKVR18-CU DRAIN. CHICAGO 131-
CFMABRCF THERMOSTATIC MIXING VALVE
ADD FILTER SYSTEM IF APPROVED BY
FACILITY. VERIFY LOCATION WITH FACILITY.
N/A N/A N/A N/A
N/A N/A N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
ACORN N/A N/A N/A N/A N/A N/A N/A N/A
SHOWER STALL
SHOWER STALL
SHOWER STALL
PP- 704
PP- 705
PP- 706
SHOWER ADA 60"X36", 60" HOSE, 30" GLIDE
RAIL, INLINE VACUUM BREAKER. GRAB
BARS,THERMOSTATIC - TEMP/PRESSURE
BALANCING MIXING SHOWER VALVE
PP- 708 GUARDIAN G1750BC-T N/A N/AEYE/FACE WASH, WALL MOUNTED SS BOWL AND COVER
CHROME PLATED TLPC AND P-TRAP
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
PROVIDE LEONARD TA-300-LF-STSTL-EXP
THERMOSTATIC MIXING VALVE.
WITH CABINET.
PROVIDE FLOOR DRAIN FOR SHOWER.
SEE ARCHITECT
DRAWINGS
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
SV16LVR-HHC15-HHSH-
HHSE-QD-GR30-IVB
SV16LVR-HHC15-HHSH-
HHSE-QD-GR30-IVB
FD-2 N/A N/A N/A N/A MIFAB F1340-Y-Q-28-3 N/A N/A N/A N/A N/A N/A N/A N/A
FLOOR DRAIN (ATTIC AREAS) - STAINLESS STEEL STRAINER,
STAINLESS STEEL BODY W/ BOTTOM OUTLET. PIPE SIZE 3
& 4 INCH. SHALLOW BODY WITH ANCHOR FLANGE.
PROVIDE ELECTRONIC TRAP PRIMER
PP-500
32"X32"X12" TERRAZZO BASIN WITH STAINLESS STEEL CAP
AND TILE FLANGES. SERVICE SINK FAUCET POLISHED
CHROME
STERN
WILLIAMS SB-702 T&S BRASS B-0665-CR-BSTR N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
PROVIDE 3" DRAIN WITH RUBBER GASKET.
HOSE & WALL HOOK. SS MOP HANGER &
SPLASH GUARDS.
N/A N/AT&S BRASS B-0669-CR-RGH
TP-1
PPP
PRECISION
PLUMBING
MPB-500-115V
WITH BOX
MINI-PRIME ELECTRONIC TRAP PRIMING MANIFOLD, 1
TO 4 FLOOR DRAINS. N/A N/A N/A N/AN/A N/A N/A N/A N/A N/A N/A N/A
PROVIDE D-814PC ACCESS DOOR.
PAINT TO MATCH WALL.
PP-532 N/A N/A N/A N/APROVIDED WITH
CASEWORK
SOLID SURFACE, 3-HOLE 4" CENTER ADA, WRIST BLADE
HANDLES, GOOSE NECK, 1.5GPM NON-AERATOR
SOLID
SURFACE
N/A N/A MCGUIRE MCGUIRE LF2165
CHICAGO 131-CFMABRCF THERMOSTATIC
MIXING VALVE. COPPER TUBING
RECOMMENDED BY CHICAGO FAUCET.
T&S BRASS B-1141-CR-B0199-29 2125PW
SEE ARCHITECT
DRAWINGS
SEE ARCHITECT
DRAWINGS
N/A N/A
N/A N/A
N/A N/A
CHICAGO 131-CFMABRCF THERMOSTATIC
MIXING VALVE. COPPER TUBING
RECOMMENDED BY CHICAGO FAUCET.
PROVIDE FLOOR DRAIN FOR SHOWER.
PROVIDE FLOOR DRAIN FOR SHOWER.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:0
:5
A
M
06-13-2023
626A4-19-101
P-PI-02
AE RENOVATE WARD 1BPLUMBING SCHEDULES
DRT
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
MEDICAL GAS VALVE BOXES
BLDG1 MEDICAL GAS OUTLETS
NOTES
NOTES
SEE PLAN FOR VALVE SIZES REQUIRED, MOUNT ALL VALVE BOXES NEAR NURSE STATIONS.3
AIR & OXYGEN
MEDICAL VACUUM, MEDICALWALL
VALVE BOX
MEDICAL GAS ZONE
MGV-1
SERVICEMARK
PROVIDED WITH EQUIPMENT, FIELD VERIFY EXACT MOUNTING LOCATION BEFORE CONSTRUCTION.2
NOTES:
1 FOR ALL WALL MOUNTED MEDICAL VACUUM OUTLETS, PROVIDE EQUAL QUANTITY OF VACUUM SLIDES.
W/ SLIDE
MARK
MGO-1 HEADWALL
2-OXY, 1-AIR & 2-VAC
MEDICAL GAS OUTLET
DESCRIPTION MOUNTING QUANTITY OF OUTLETS
DESCRIPTION MOUNTING
PROVIDE ALARM PANEL AND MED GAS SENSORS. FIELD VERIFY LOCATION AND CONNECT TO EXISTING MASTER ALARM PANEL. 4
X3 X3
X4
X9
X11
X12
X13
X14
XI XJ
XK
XL XM XN XO
XP
XQ XR
X6.1
X7.1
X12.1
X12.2 X12.3
X8
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
02.10
02.17
02.50
02.11
02.50
02.26
02.35
VALVE & CAP
CW, HW & HWR
RELOCATE CW, HW
& HWR PIPING UP
FROM BELOW.
3/4" H & CW
DOWN
1-1/2" CW & 1/2"
HW UP & DOWN
REMOVE CW
& HW PIPING UP
FROM BELOW.
REMOVE CW
& HW PIPING UP
FROM BELOW.
1/2" H & CW
UP & DOWN
REMOVE CW
& HW PIPING UP
FROM BELOW.
1-1/2" CW & 1"
HW DOWN
1/2" HW &
CW DOWN
REMOVE EXISTING
CW, HW & HWR
PIPING.
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
PLUMBING FIXTURES
EXISTING SAN.
UP & DOWN
EXISTING SAN.
UP & DOWN
REMOVE EXISTING
SANITARY PIPING.
REMOVE EXISTING
SANITARY PIPING.
REMOVE EXISTING
SANITARY PIPING.
REMOVE EXISTING
SANITARY PIPING.
EXISTING VENT
DOWN
EXISTING SAN.
UP & DOWN
REMOVE EXISTING
VENT PIPING
EXISTING
CW, HW &
HWR RISERS
UP FROM
BELOW
NOTE:
LEVEL EXISTING FLOOR SLAB TO PREPARE FOR NEW WORK PLAN.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:0
:1
A
M
06-13-2023
626A4-19-101
P-PD-01
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR- PART A -
PLUMBING - DEMO
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PART A - PLUMBING - DEMO
GENERAL GRAVITY DEMOLITION NOTES
1. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO DEMOLITION. FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY LOCATIONS OF EXISTING PIPING BEFORE DEMOLITION. PROVIDE ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. COORDINATE WITH THE ARCHITECTURAL DRAWING FOR ITEMS NOT INDICATED. COORDINATE DEMOLITION OF EXISTING PIPING WITH NEW WORK. PIPING CONNECTING TO AREAS OUTSIDE OF RENOVATED SPACE SHALL NOT TO BE DISCONNECTED UNTIL AFTER NEW PIPING IS INSTALLED. COORDINATE SYSTEM SHUT DOWNS WITH THE FACILITY PRIOR TO DEMOLITION. REFER TO
WARD-1A DESIGN DRAWINGS AS A SOURCE OF INFORMATION FOR EXISTING CONDITIONS.
2. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE TURNED OVER TO THE OWNER, OR DISPOSED OF
AT THE OWNER'S DISCRETION.
3. ALL VENT PIPING INDICATED ON THIS DRAWING IS LOCATED IN THE CEILING SPACE OR WALL SPACES
UNLESS NOTED OTHERWISE, FIELD VERIFY BEFORE CONSTRUCTION.
4. ALL SANITARY PIPING INDICATED ON THIS DRAWING IS LOCATED BELOW THE FLOOR SLAB OR WALL CHASE UNLESS NOTED OTHERWISE. OFFSET ALL EXISTING SANITARY AND VENT RISERS FROM FLOOR ABOVE TO WALLS ON NEW FLOOR PLAN, FIELD VERIFY EXACT LOCATION AND PROVIDE REQUIRED OFFSET TO FACILITATE OPERATION OF PLUMBING SYSTEMS TO THE FLOORS ABOVE AND BELOW.
5. CARE MUST BE TAKEN WHEN REMOVING PIPE AROUND LOAD BEARING WALLS. THE WALL OR FOOTING
BELOW IS NOT TO BE DESTROYED.
6. EXISTING ROOF DRAINS AND RAIN WATER LEADER PIPING TO REMAIN UNLESS OTHERWISE NOTED. FIELD VERIFY ROUTING OF EXISTING PIPING BEFORE CONSTRUCTION BEGINS. EXISTING RAIN WATER PIPING LOCATED IN WALLS TO BE REMOVED SHALL BE REROUTED OVER HEAD TO A NEW WALL LOCATION AND
RECONNECTED TO THE UNDERGROUND STORM.
7. CUT AND PATCH CEILINGS, WALLS AND FLOOR SLAB AS REQUIRED TO FACILITATE PLUMBING
RENOVATION. SEE ARCHITECTURAL DRAWINGS FOR PATCHING DETAILS.
8. REFER TO WARD1A DRAWINGS. WARD1A RENOVATION TO BE COMPLETED BEFORE WORK ON WARD1B
BEGINS.
1. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO DEMOLITION. FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY LOCATIONS OF EXISTING PIPING BEFORE DEMOLITION. PROVIDE ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. COORDINATE WITH THE ARCHITECTURAL DRAWING FOR ITEMS NOT INDICATED. COORDINATE DEMOLITION OF EXISTING PIPING WITH NEW WORK. PIPING CONNECTING TO AREAS OUTSIDE OF RENOVATED SPACE SHALL NOT TO BE DISCONNECTED UNTIL AFTER NEW PIPING IS INSTALLED.
COORDINATE SYSTEM SHUT DOWNS WITH THE FACILITY PRIOR TO DEMOLITION. REFER TO WARD-1A DESIGN
DRAWINGS AS A SOURCE OF INFORMATION FOR EXISTING CONDITIONS
2. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF OR TURNED OVER TO THE OWNER AT
THE OWNER'S DISCRETION.
3. ALL WATER PIPING INDICATED ON THIS DRAWING IS LOCATED IN THE CEILING SPACE OR WALL SPACES
UNLESS NOTED OTHERWISE, FIELD VERIFY BEFORE CONSTRUCTION.
4. CARE MUST BE TAKEN WHEN REMOVING PIPE AROUND LOAD BEARING WALLS. THE WALL OR FOOTING BELOW
IS NOT TO BE DESTROYED.
5. CUT AND PATCH CEILINGS, WALLS AND FLOOR SLAB AS REQUIRED TO FACILITATE PLUMBING RENOVATION.
SEE ARCHITECTURAL DRAWINGS FOR PATCHING DETAILS.
GENERAL PLUMBING ZONE NOTES
GENERAL NOTE:
PLUMBING CONTRACTOR TO REMOVE EXISTING PLUMBING PIPING AND
INSULATION. ASBESTOS ABATEMENT SERVICES REQUIRED.
X1
X2
X3
X4
X9
X10
X11
X0
XB XC XD XE XF XG XH XI XJ
XK
X6.1
X7.1
X12.2 X12.3
X8
XA
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
B
02.10
02.1102.11
02.1302.13
02.16
02.17
02.26
02.26
02.35
02.50
02.50
02.50
1-1/2" CW & 1"
HW UP FROM
BELOW
VALVE & CAP
CW, HW & HWR
2-1/2" CW, 1-1/4"
HW & 1/2" HWR UP
TO REMAIN.
RELOCATE CW, HW
& HWR PIPING UP
FROM BELOW. REMOVE EXISTING
PLUMBING FIXTURES
HWR
HW
CW
REMOVE
1/2" H & CW
UP FROM
BELOW
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE 1"
CW & 3/4"
HW UP FROM
BELOW
REMOVE
1/2" H & CW
UP FROM
BELOW
1-1/2" CW & 3/4"
HW UP FROM
BELOW
REMOVE
1-1/2" CW & 1/2"
HW UP FROM
BELOW
REMOVE EXISTING
ICE MACHINE
REMOVE EXISTING
CW, HW & HWR
PIPING.
EXISTING
SAN. &
VENT
EXISTING
VENT
EXISTING
SANITARY
EXISTING
SANITARY
EXISTING
SANITARY
EXISTING
SANITARY
EXISTING
VENT
EXISTING
VENT
EXISTING CW,
HW & HWR
RISERS
EXISTING CW,
HW & HWR
RISERS
EXISTING CW,
HW & HWR
RISERS
EXISTING
SANITARY
EXISTING
SANITARY
EXISTING
SANITARY
EXISTING
SANITARY
EXISTING
VENT
EXISTING
VENT
EXISTING
VENT
EXISTING
VENT
EXISTING
VENT
NOTE:
LEVEL EXISTING FLOOR SLAB TO PREPARE FOR NEW WORK PLAN.
GENERAL NOTE:
PLUMBING CONTRACTOR TO REMOVE EXISTING PLUMBING PIPING AND
INSULATION. ASBESTOS ABATEMENT SERVICES REQUIRED.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:0
:1
A
M
06-13-2023
626A4-19-101
P-PD-02
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR- PART B -
PLUMBING - DEMO
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PART B - PLUMBING - DEMO
GENERAL GRAVITY DEMOLITION NOTES
1. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO DEMOLITION. FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY LOCATIONS OF EXISTING PIPING BEFORE DEMOLITION. PROVIDE ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. COORDINATE WITH THE ARCHITECTURAL DRAWING FOR ITEMS NOT INDICATED. COORDINATE DEMOLITION OF EXISTING PIPING WITH NEW WORK. PIPING CONNECTING TO AREAS OUTSIDE OF RENOVATED SPACE SHALL NOT TO BE DISCONNECTED UNTIL AFTER NEW PIPING IS INSTALLED. COORDINATE SYSTEM SHUT DOWNS WITH THE FACILITY PRIOR TO DEMOLITION. REFER TO
WARD-1A DESIGN DRAWINGS AS A SOURCE OF INFORMATION FOR EXISTING CONDITIONS.
2. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE TURNED OVER TO THE OWNER, OR DISPOSED OF
AT THE OWNER'S DISCRETION.
3. ALL VENT PIPING INDICATED ON THIS DRAWING IS LOCATED IN THE CEILING SPACE OR WALL SPACES
UNLESS NOTED OTHERWISE, FIELD VERIFY BEFORE CONSTRUCTION.
4. ALL SANITARY PIPING INDICATED ON THIS DRAWING IS LOCATED BELOW THE FLOOR SLAB OR WALL CHASE UNLESS NOTED OTHERWISE. OFFSET ALL EXISTING SANITARY AND VENT RISERS FROM FLOOR ABOVE TO WALLS ON NEW FLOOR PLAN, FIELD VERIFY EXACT LOCATION AND PROVIDE REQUIRED OFFSET TO FACILITATE OPERATION OF PLUMBING SYSTEMS TO THE FLOORS ABOVE AND BELOW.
5. CARE MUST BE TAKEN WHEN REMOVING PIPE AROUND LOAD BEARING WALLS. THE WALL OR FOOTING
BELOW IS NOT TO BE DESTROYED.
6. EXISTING ROOF DRAINS AND RAIN WATER LEADER PIPING TO REMAIN UNLESS OTHERWISE NOTED. FIELD VERIFY ROUTING OF EXISTING PIPING BEFORE CONSTRUCTION BEGINS. EXISTING RAIN WATER PIPING LOCATED IN WALLS TO BE REMOVED SHALL BE REROUTED OVER HEAD TO A NEW WALL LOCATION AND
RECONNECTED TO THE UNDERGROUND STORM.
7. CUT AND PATCH CEILINGS, WALLS AND FLOOR SLAB AS REQUIRED TO FACILITATE PLUMBING
RENOVATION. SEE ARCHITECTURAL DRAWINGS FOR PATCHING DETAILS.
8. REFER TO WARD1A DRAWINGS. WARD1A RENOVATION TO BE COMPLETED BEFORE WORK ON WARD1B
BEGINS.
1. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO DEMOLITION. FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY LOCATIONS OF EXISTING PIPING BEFORE DEMOLITION. PROVIDE ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. COORDINATE WITH THE ARCHITECTURAL DRAWING FOR ITEMS NOT INDICATED. COORDINATE DEMOLITION OF EXISTING PIPING WITH NEW WORK. PIPING CONNECTING TO AREAS OUTSIDE OF RENOVATED SPACE SHALL NOT TO BE DISCONNECTED UNTIL AFTER NEW PIPING IS INSTALLED.
COORDINATE SYSTEM SHUT DOWNS WITH THE FACILITY PRIOR TO DEMOLITION. REFER TO WARD-1A DESIGN
DRAWINGS AS A SOURCE OF INFORMATION FOR EXISTING CONDITIONS
2. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF OR TURNED OVER TO THE OWNER AT
THE OWNER'S DISCRETION.
3. ALL WATER PIPING INDICATED ON THIS DRAWING IS LOCATED IN THE CEILING SPACE OR WALL SPACES
UNLESS NOTED OTHERWISE, FIELD VERIFY BEFORE CONSTRUCTION.
4. CARE MUST BE TAKEN WHEN REMOVING PIPE AROUND LOAD BEARING WALLS. THE WALL OR FOOTING BELOW
IS NOT TO BE DESTROYED.
5. CUT AND PATCH CEILINGS, WALLS AND FLOOR SLAB AS REQUIRED TO FACILITATE PLUMBING RENOVATION.
SEE ARCHITECTURAL DRAWINGS FOR PATCHING DETAILS.
GENERAL PLUMBING ZONE NOTES
X1
X2
X3
X4
X9
X10
X0
XS XT XU XV XW XX XY
X6.1
X7.1
XZ
X8
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
02.10
02.11
02.17
02.50
02.26
02.16
02.1302.13
02.35
REMOVE
2" CW & 1-1/2"
HW UP FROM
BELOW.
REMOVE
1-1/2" HW & 1"
HW UP FROM
BELOW.
REMOVE
1/2" H & CW
UP FROM
BELOW
3/4" H & CW
UP FROM
BELOW.
REMOVE
1-1/2" CW & 1/2"
HW UP FROM
BELOW.
REMOVE
3/4" H & CW
UP FROM
BELOW
REMOVE
1-1/2" CW & 1"
HW UP FROM
BELOW.
HWR HW
CW
HWRCW
HW
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
PLUMBING FIXTURES
REMOVE EXISTING
CW, HW & HWR
PIPING SAN.
DOWN
VENT UP
& DOWN
VENT UP
EXISTING
SAN.
SAN.
DOWN
EXISTING HW,
CW & HWR RISERS
SAN.
DOWN
SAN.
DOWN
VENT UP
& DOWN
EXISTING
4" VTR
SAN.
DOWN
REMOVE EXISTING
VENT PIPING
REMOVE EXISTING
SANITARY PIPING.
NOTE:
LEVEL EXISTING FLOOR SLAB TO PREPARE FOR NEW WORK PLAN.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:0
:2
A
M
06-13-2023
626A4-19-101
P-PD-03
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR- PART C -
PLUMBING - DEMO
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PART C - PLUMBING - DEMO
GENERAL GRAVITY DEMOLITION NOTES
1. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO DEMOLITION. FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY LOCATIONS OF EXISTING PIPING BEFORE DEMOLITION. PROVIDE ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. COORDINATE WITH THE ARCHITECTURAL DRAWING FOR ITEMS NOT INDICATED. COORDINATE DEMOLITION OF EXISTING PIPING WITH NEW WORK. PIPING CONNECTING TO AREAS OUTSIDE OF RENOVATED SPACE SHALL NOT TO BE DISCONNECTED UNTIL AFTER NEW PIPING IS INSTALLED. COORDINATE SYSTEM SHUT DOWNS WITH THE FACILITY PRIOR TO DEMOLITION. REFER TO
WARD-1A DESIGN DRAWINGS AS A SOURCE OF INFORMATION FOR EXISTING CONDITIONS.
2. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE TURNED OVER TO THE OWNER, OR DISPOSED OF
AT THE OWNER'S DISCRETION.
3. ALL VENT PIPING INDICATED ON THIS DRAWING IS LOCATED IN THE CEILING SPACE OR WALL SPACES
UNLESS NOTED OTHERWISE, FIELD VERIFY BEFORE CONSTRUCTION.
4. ALL SANITARY PIPING INDICATED ON THIS DRAWING IS LOCATED BELOW THE FLOOR SLAB OR WALL CHASE UNLESS NOTED OTHERWISE. OFFSET ALL EXISTING SANITARY AND VENT RISERS FROM FLOOR ABOVE TO WALLS ON NEW FLOOR PLAN, FIELD VERIFY EXACT LOCATION AND PROVIDE REQUIRED OFFSET TO FACILITATE OPERATION OF PLUMBING SYSTEMS TO THE FLOORS ABOVE AND BELOW.
5. CARE MUST BE TAKEN WHEN REMOVING PIPE AROUND LOAD BEARING WALLS. THE WALL OR FOOTING
BELOW IS NOT TO BE DESTROYED.
6. EXISTING ROOF DRAINS AND RAIN WATER LEADER PIPING TO REMAIN UNLESS OTHERWISE NOTED. FIELD VERIFY ROUTING OF EXISTING PIPING BEFORE CONSTRUCTION BEGINS. EXISTING RAIN WATER PIPING LOCATED IN WALLS TO BE REMOVED SHALL BE REROUTED OVER HEAD TO A NEW WALL LOCATION AND
RECONNECTED TO THE UNDERGROUND STORM.
7. CUT AND PATCH CEILINGS, WALLS AND FLOOR SLAB AS REQUIRED TO FACILITATE PLUMBING
RENOVATION. SEE ARCHITECTURAL DRAWINGS FOR PATCHING DETAILS.
8. REFER TO WARD1A DRAWINGS. WARD1A RENOVATION TO BE COMPLETED BEFORE WORK ON WARD1B
BEGINS.
1. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL DRAWINGS. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO DEMOLITION. FIELD CONDITIONS SHALL GOVERN. FIELD VERIFY LOCATIONS OF EXISTING PIPING BEFORE DEMOLITION. PROVIDE ALL REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. COORDINATE WITH THE ARCHITECTURAL DRAWING FOR ITEMS NOT INDICATED. COORDINATE DEMOLITION OF EXISTING PIPING WITH NEW WORK. PIPING CONNECTING TO AREAS OUTSIDE OF RENOVATED SPACE SHALL NOT TO BE DISCONNECTED UNTIL AFTER NEW PIPING IS INSTALLED.
COORDINATE SYSTEM SHUT DOWNS WITH THE FACILITY PRIOR TO DEMOLITION. REFER TO WARD-1A DESIGN
DRAWINGS AS A SOURCE OF INFORMATION FOR EXISTING CONDITIONS
2. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF OR TURNED OVER TO THE OWNER AT
THE OWNER'S DISCRETION.
3. ALL WATER PIPING INDICATED ON THIS DRAWING IS LOCATED IN THE CEILING SPACE OR WALL SPACES
UNLESS NOTED OTHERWISE, FIELD VERIFY BEFORE CONSTRUCTION.
4. CARE MUST BE TAKEN WHEN REMOVING PIPE AROUND LOAD BEARING WALLS. THE WALL OR FOOTING BELOW
IS NOT TO BE DESTROYED.
5. CUT AND PATCH CEILINGS, WALLS AND FLOOR SLAB AS REQUIRED TO FACILITATE PLUMBING RENOVATION.
SEE ARCHITECTURAL DRAWINGS FOR PATCHING DETAILS.
GENERAL PLUMBING ZONE NOTES
GENERAL NOTE:
PLUMBING CONTRACTOR TO REMOVE EXISTING PLUMBING PIPING AND
INSULATION. ASBESTOS ABATEMENT SERVICES REQUIRED.
X9
X10
X11
X12
X13
X14
XI XJ
XK
XL XM XN XO
XP
XQ XR
X6.1
X7.1
X12.1
X12.2 X12.3
X8
X5
X6
X7
EXISTING 1-1/2" MED
VAC, 3/4" OXYGEN &
3/4" MED AIR.
MV
OX
MA
RELOCATE MED
GAS PIPING
FROM BELOW.
REMOVE EXISTING
MED GAS WALL
OUTLETS.
MV
OX
MA
REMOVE EXISTING
MED GAS ZONE
VALVE BOX.
VALVE & CAP
MED GAS PIPING
GOING TO FLOOR
ABOVE.
REMOVE EXISTING
MED GAS PIPING.
REMOVE EXISTING
MED GAS WALL
OUTLETS.
REMOVE EXISTING
MED GAS PIPING.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:1
:1
A
M
06-13-2023
626A4-19-101
P-PD-04
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR- PART A - MED
GAS - DEMO
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PART A - MED GAS - DEMO
X1X1
X2 X2
X3 X3
X4
X9
X10
X11
X0 X0
XB XC XD XE XF XG XH XI XJ
XK
X6.1
X7.1
X12.2 X12.3
X8
XA
X5
X6
X7
REMOVE EXISTING
MED GAS WALL
OUTLETS.
REMOVE EXISTING
MED GAS WALL
OUTLETS.
REMOVE EXISTING
MED GAS WALL
OUTLETS.
REMOVE EXISTING
MED GAS PIPING.
MV
OX
MA
MV
OX
MA
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:1
:1
A
M
06-13-2023
626A4-19-101
P-PD-05
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR- PART B - MED
GAS - DEMO
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PART B - MED GAS - DEMO
X3 X3
X4
X9
X10
X0 X0
XS XT XU XV XW XX XY
X6.1
X7.1
XZ
X8
X5
X6
X7 MV
OX
MA
EXISTING MED
GAS RISERS
TO REMAIN.
VALVE &
CAP.
REMOVE EXISTING
MED GAS ZONE
VALVE BOX.
REMOVE EXISTING
MED GAS WALL
OUTLETS.
MV
OX
MA
REMOVE EXISTING
MED GAS WALL
OUTLETS.
REMOVE EXISTING
MED GAS PIPING.
REMOVE EXISTING
MED GAS PIPING.
MV
MA
OX
REMOVE EXISTING
MED GAS WALL
OUTLETS.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:1
:1
A
M
06-13-2023
626A4-19-101
P-PD-06
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR- PART C - MED
GAS - DEMO
DRT
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
3/16" = 1'-0"
1 PARTIAL THIRD FLOOR PART C - MED GAS - DEMO
RQI
(OFOI) RQI
(OFOI)
RQI
(OFOI)
RQI
(OFOI)
RQI
(OFOI)
RQI
(OFOI)
EXISTING SANITARY
IN CEILING OF 3RD
FLOOR.
X3 X3
X4
X9
X10
X11
X12
X13
XI XJ
XK
XL XM XN XO
XP
XQ XR
X6.1
X7.1
X12.1
X12.2 X12.3
X8
X5
X6
X7
EXISTING
4" SAN.
DOWN
CO
CO
EXISTING
4" SAN.
DOWN
EXISTING
4" VTR
EXISTING VENT
PIPING TO REMAIN.
REMOVE EXISTING
SANITARY PIPING
REMOVE EXISTING
SANITARY PIPING
EXISTING VENT
PIPING TO REMAIN.
REMOVE EXISTING
SANITARY PIPING
REMOVE EXISTING
SANITARY PIPING
EXISTING
4" SAN.
DOWN
CO
EXISTING VENT
PIPING TO REMAIN.
REMOVE EXISTING
SANITARY PIPING
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:0
:3
A
M
06-13-2023
626A4-19-101
P-PD-07
AE RENOVATE WARD 1BFOURTH FLOOR - PLUMBING - DEMO
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
1 FOURTH FLOOR - PLUMBING - DEMO
0 2' 4' 8'1'
NOTES:
1. DISCONNECT PLUMBING FIXTURES ON FOURTH FLOOR IN CEILING OF THIRD FLOOR.
EXISTING HORIZONTAL SANITARY LINES IN CEILING OF THIRD FLOOR TO BE REMOVED.
2. PREPARE EXISTING TO CONNECT TO NEW HORIZONTAL SANITARY PIPING IN THIRD
FLOOR CEILING.
3. EXISTING PLUMBING FIXTURES TO REMAIN.
EXISTING PLUMBING
FIXTURES TO REMAIN
ON FOURTH FLOOR.
EXISTING PLUMBING
FIXTURES TO REMAIN
ON FOURTH FLOOR.
DN DN
DN UP
PLUMBING ZONE "A"
P
LU
M B
IN
G
Z O
N E
C
P
LU
M B
IN
G
Z O
N E
C
PLUMBING ZONE "B"
PLUMBING ZONE "B"PLUMBING ZONE "A"
PLUMBING ZONE "D"
P
LU
M B
IN
G
Z O
N E
E
PLUMBING ZONE "F"
PLUMBING ZONE "F"
P
LU
M B
IN
G
Z O
N E
G
P
LU
M B
IN
G
Z O
N E
G
PLUMBING ZONE "H"
PLUMBING ZONE "H"
PLUMBING ZONE "J"
PLUMBING ZONE "J"
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls \1
-A lv in
C .Y o rk
P L
U M
B R
D a n n y .t h o m a s tl c -e n g
.c o m .r v t
/1
/2
:0
:5
A
M
06-13-2023
626A4-19-101
P-PP-01
AE RENOVATE WARD 1BPLUMBING - SECOND FLOOR ZONE PLAN
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
3/32" = 1'-0"
1 SECOND FLOOR ZONE PLAN
0 5' 10'
GENERAL PLUMBING ZONE NOTES
1. THE INTENT OF IDENTIFYING THE PLUMBING ZONES IS TO PROVIDE THE CONTRACTOR THE INTENT OF IDENTIFYING THE PLUMBING ZONES IS TO PROVIDE THE CONTRACTOR LIMITS TO WHICH AREA'S ON THE 1ST AND
3RD FLOOR ARE AFFECTED BY PLUMBING DEMO AND NEW WORK ON THE 2ND FLOOR.
2. THE IDENTIFYING OF PLUMBING ZONES IS NOT TO BE TAKEN AS AN ALL INCLUSIVE THE IDENTIFYING OF PLUMBING ZONES IS NOT TO BE TAKEN AS AN ALL INCLUSIVE WORK AREA. PLEASE REFER TO ALL DISCIPLINES
AND CONTRACT DOCUMENTS FOR ALL WORK ASSOCIATED AND AFFECTED BY THESE AREAS.
3. WORK CAN OCCUR CONCURRENTLY BETWEEN DIFFERENT IDENTIFIED ZONES AND WORK CAN OCCUR CONCURRENTLY BETWEEN DIFFERENT IDENTIFIED ZONES AND WORK BETWEEN ZONES DOES NOT NEED TO
OCCUR IN SEQUENCE.
4. WORK ACROSS ALL DISCIPLINES IS SUBJECT TO THE CONTRACTORS MEANS AND WORK ACROSS ALL DISCIPLINES IS SUBJECT TO THE CONTRACTORS MEANS AND METHODS, SCHEDULING AND TO EXISTING
CONDITIONS AND TIME RESTRAINTS.
5. THE CONTRACTOR TO HAVE ALL MATERIALS AND EQUIPMENT ON SITE PRIOR TO THE CONTRACTOR TO
STARTING ANY WORK THAT IS DESIGNATED TO BE COMPLETED OFF-HOURS.
6.WORK ASSOCIATED WITH THESE ZONES CAN BE DONE AT HOURS APPROVED BY FACILITY.
7. REFER TO WARD1A RENOVATION PLANS FOR EXISTING CONDITIONS.
GENERAL SEQUENCE OF WORK NOTES
1. CONTRACTOR SHALL BE RESPONSIBLE FOR SEQUENCING AND COORDINATION OF CONSTRUCTION PHASING WITH THE VA'S SCHEDULE, INFECTION CONTROL, AND INTERIM LIFE SAFETY REQUIREMENTS. REFER TO SPECIFICATIONS FOR PROJECT GENERAL CONDITIONS, INFECTION CONTROL, SPECIAL NOTES, PROJECT
SCHEDULE, ETC. FOR ALL PROJECT REQUIREMENTS.
2. CONTRACTOR SHALL PROVIDE ALL SUB-PHASING ACTIVITIES AS REQUIRED FOR WORK CONTRACTOR SHALL PROVIDE ALL SUB-PHASING ACTIVITIES AS REQUIRED FOR WORK OCCURRING BETWEEN VARIOUS PHASES.
3. CONTRACTOR SHALL REFER TO ALL DEMOLITION AND CONSTRUCTION DRAWINGS FOR CONTRACTOR SHALL REFER TO ALL DEMOLITION AND CONSTRUCTION DRAWINGS FOR A COMPLETE UNDERSTANDING OF THE
SPECIFIED SCOPE OF WORK.
4. CONTRACTOR SHALL MAINTAIN EGRESS PASSAGE WAYS AT INTERIOR OF BUILDING xxx CONTRACTOR SHALL MAINTAIN EGRESS PASSAGE WAYS AT INTERIOR OF BUILDING xxx DURING COMPLETE PROJECT DURATION. ALSO
MAINTAIN ALL EGRESS/EXIT DOORS OF THE FACILITY.
5. CONTRACTOR SHALL REFER TO DRAWING G-00, G-00 AND G-00 FOR INFECTION CONTRACTOR SHALL REFER TO DRAWING G-00, G-00 AND G-00 FOR INFECTION CONTROL NOTES AND SUGGESTED LOCATION OF
CONSTRUCTION BARRIERS AND ENTRANCES.
6. CONTRACTOR SHALL NOTE THAT BUILDING 1 SHALL BE OCCUPIED DURING CONTRACTOR SHALL NOTE THAT
BUILDING 1 SHALL BE OCCUPIED DURING CONSTRUCTION.
7. HOURS OF OPERATION FOR NOISE AND VIBRATION OPERATIONS ARE DURING OFF HOURS OF OPERATION FOR NOISE AND VIBRATION OPERATIONS ARE DURING OFF NORMAL HOSPITAL OPERATION HOURS (6:00PM TO 6:00AM). SERVICE INTERRUPTIONS DURING OFF NORMAL WORK HOURS AND SCHEDULED MINIMUM (2) WEEK
ADVANCED NOTICE.
8. PLUMBING ZONES ARE INDICATED ON PLANS. NO SEQUENCE IS INFERRED
GENERAL NOTE:
VERIFY AND COORDINATE LOCATION OF EXISTING DUCT OR PIPING ABOVE CEILING FOR NEW PLUMBING FIXTURES ABOVE.
EXISTING DUCT OR PIPING MAY NEED TO BE REMOVED THEN REINSTALLED TO ROUGH-IN NEW PLUMBING FIXTURES.
FEC
F E
C
CR CR
CR
C R
X3 X3
X4 X4
X9 X9X11
X12
X13
X14
XI XJ
XK
XL XM XN XO
XP
XQ XR
X6.1 X6.1
X7.1 X7.1
X12.1
X12.2
X12.3
X8 X8
X5 X5
X6 X6
X7 X7
PANTRY
B338A
SERVING KITCHEN
B338
DINING/DAY ROOM
B337
RETHERM
B361
LAUNDRY
B359 CLEAN SUPPLY
B363
CHUTE
B360
NURSE STATION
B336
EQUIP STORAGE
B301
INPATIENT REHAB
B303
STAFF LOUNGE
B304
STAFF LOCKERS
B304B
CHAIR ALCOVE
B305
FAM. LOUNGE
B307
CONSULT
B310
FAM/PUB. TLT.
B308
REC.THR. STOR.
B309
TEAM ROOM
B332
DATA
B335
PAT. TLT.
B331A
PRIVATE ROOM
B331
CHARGE NURSE
B336A
SOCIAL WORKER
B302
DIRTY
B362
NURSE MANAGER
B333
MEDS
B336B
COMM
B334
STAFF TLT.
B304A
CORRIDOR
B300
CORRIDOR
B370
VENDING
B300A
EXISTING RISER
B370A
ELEV.
ELEV.
STAIR 1
STAIR 1
B306
3" S
3" S
2" S
2" S
2" S
2" S
4" S
4" S
2" S
2" S
4" S
4" S
4" S
CO
CO
3" S
2" S
3" S
2" S
4" VENT UP
& NEW 4" VTR.
SEE ATTIC PLAN
4" VTR
4" VENT UP
& NEW 4" VTR.
SEE ATTIC PLAN
CAP 3" VENT
CAP 3" VENT
3" V
2" V
3" V
3" V
2" V
3" V
2" V
2" V
2" V
3" S
2" V
2" V
2" V
3" V
2" V
CAP 3" VENT
SANITARY CONNECTION
LOCATION IS APPROXIMATE
BASED ON FUTURE
RENOVATIONS OF WARD1A.
SANITARY CONNECTION
LOCATION IS APPROXIMATE
BASED ON FUTURE
RENOVATIONS OF WARD1A.
SANITARY CONNECTION
LOCATION IS APPROXIMATE
BASED ON FUTURE
RENOVATIONS OF WARD1A.
PP-808
PP-528
FD-1
PP-401
PP-401
PP-401
PP-101
PP-401
PP-101
PP-529
PP-529
2" S
3" V
EXISTING
ETO VENT
LINES UP
ETO VENT LINES
DOWN. CONNECT
TO EXISTING LINES
IN CEILING BELOW.
FIELD VERIFY EXACT
LOCATION.
FD-1
NOTE:
LEVELING OF THE EXISTING FLOOR SLAB
SHALL BE DONE TO PREPARE FOR NEW
PLAN LAYOUT. NEW FLOOR TO BE SLOPED
FOR ROOMS WITH NEW FLOOR DRAINS.
2" V
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG…