About this file

This document contains a technical data sheet for a swing-up grab bar product and a related federal contract opportunity notice. The technical data sheet provides specifications for a Model #3413-25 swing-up grab bar fabricated from type 304 stainless steel tubing with a satin finish. It has a hinged design that can be operated with one hand, mounts to the wall with three screws, and includes plastic end caps. Dimensions, mounting information, and compliance with ADA accessibility standards are specified. The product has a one year warranty and is intended to meet load capacity requirements.

The related federal contract opportunity is solicitation number 36C24923R0114 to renovate Ward 1B at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The solicitation is issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. No further details are provided regarding response dates, award dates, pricing terms, set asides, or incumbent contractors.

View the file

Other files

File Type Posted
36C24923R0114 0003.docx DOCX document
E-EI-01 - PARTIAL ELECTRICAL RISER DIAGRAM - DEMOLITION.pdf PDF
119437-Alvin C. York VAMC Renovate Ward 1B - Revision 1 - Electrical Narrative.pdf PDF
Government Answers to Industry Questions.pdf PDF
283100.pdf PDF
275223.pdf PDF
Bradley_GrabBar_8370-107.pdf PDF
Ward 1B - Revision 1.pdf PDF
Renovate Ward 1B Pre-Proposal Sign in Sheet - 07-06-2023.pdf PDF
E-EI-02 - PARTIAL ELECTRICAL RISER DIAGRAM - NEW WORK.pdf PDF
Bradley_GrabBar_8370-108.pdf PDF
General Decision Number TN20230187 06-30-2023 Rutherford County TN.pdf PDF
36C24923R0114 0002.docx DOCX document
GAMCO 125SwingUpTP.pdf PDF
Interior Wall Type Legend.pdf PDF
SUBCONTRACTOR INFORMATION AND CONSENT FORM.docx DOCX document
36C24923R0114 0001.docx DOCX document
MECH BINDER.pdf PDF
Ward 1B - Specs - Vol. 2.pdf PDF
GD Number TN20230187 05-12-2023.pdf PDF
GI 01-02 - CONSTRUCTION STAGING PLAN.pdf PDF
GI 03-01 - SECOND FLOOR ICRA PLAN.pdf PDF
GI 05-01 - PHASING PLANS.pdf PDF
GI 00-01 - COVER SHEET.pdf PDF
GI 01-10 - WALL TYPE DETAILS.pdf PDF
Price Schedule Project 626A4-19-101 Renovate Ward 1B.xlsx XLSX spreadsheet
GI 04-02 - LEAD PAINT AND TRANSITE PANELS.pdf PDF
36C24923R0114.docx DOCX document
General Conditions Breakout.xlsx XLSX spreadsheet
WARD 1B - ARCH BINDER.pdf PDF
GI 01-20 - ACCESSIBILITY DETAILS.pdf PDF
RFI Form.docx DOCX document
GI 04-01 - ACM DUCT WORK AND ACM PIPE INSULATION.pdf PDF
Performance Relevancy Survey Form - 626A4-19-101 Renovate Ward 1B.docx DOCX document
Ward 1B - Specs - Vol. 1.pdf PDF
VN 01-00 - PATIENT LIFT VENDOR DRAWINGS.pdf PDF
ELECTRICAL BINDER.pdf PDF
PLUMBING BINDER.pdf PDF
GI 01-01 - GENERAL DATA.pdf PDF
TECH BINDER.pdf PDF
WARD 1B - GENERAL.pdf PDF
WARD 1B - INTERIORS .pdf PDF
Calculation of Self Performed Work.docx DOCX document
GI 02-01 - THIRD FLOOR LIFE SAFETY PLAN - OVERALL.pdf PDF
AD 01-01 - THIRD FLOOR DEMOLITION PLAN - OVERALL.pdf PDF
Contractor EMR Certification Form.docx DOCX document
FP BINDER.pdf PDF
GI 03-02 - THIRD FLOOR ICRA PLAN.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scan for Information

Technical Data Sheet

Product overview Swing-Up Grab Bar is fabricated of stainless steel type 304 alloy 18-8 with a satin finish. The bar has 1-1/4" [32] diameter tubing hinge. Operable with one hand. Bar mounting plate includes top arm stop bumper to prevent raised arm from banging into wall. Bar tube includes plastic end cap to cushion contact with wall plate in use position.

Grab Bars

Key Features & sPeciFications

• Swing-Up Grab Bar also holds Toilet Paper

• Exposed Flange - 3" diameter [Ø76], 1/8" [3] thick

• Type 304 Stainless Steel - Satin Finish

• Surface Mounted - See Diagram Backplate mounting holes

• 18 gauge tubing with 1-1/4" Outside Diameter [Ø32]

• 18" [457] Length

American Specialties, Inc. | 441 Saw Mill River Road, Yonkers, NY 10701 | (914) 476-9000 | www.americanspecialties.com Model:#3413-25 Issued: 11/1/2021 Revised: 5/31/2023

Page: 1 of 2 Revision: R3

6" [152]

10" [254]

5-1/8" [130]

7" [178]

4-3/4" [121]

4-5/8" [117]

2-5/8" [67]

5/8" [16]

TYP

1-3/4" [44]

PLASTIC

END CAPS

1/4" DIA [Ø6]

MOUNTING

HOLES TYP [7]

1-1/4" [32]

NON-SLIP AREA WHEN

PEENED (-P) SPECIFIED

36" [914] AFF

RUBBER STOP ON

CENTER SCREW

33" [838] AFF

PLASTIC END CAP

8-1/4" [210]

2-7/8" [73]

5-3/8" [137]

A

A

16-1/8" [410]

1-5/8" [41]

REF

1-1/2" DIA [Ø38] MAX REF

OPTIONAL GRAB BAR

RUBBER STOP ON

CENTER SCREW

1-1/2" [38] REF

5/8" [16]

30" [762]

CL

CL

CL

CL CL

CL

CL

CL

CL

CL

sustainability/leed

1-1/4" Dia. Swing-Up Grab Bar with Integral Toilet Paper Roll Holder

2Toilet AccessoriesCSI:10 28 13

Model #3413-25

MasterFormat Section 10 28 13

MR 4.1 (1)

MR 4.2 (1)

MR 6 (1)

EQ 4.1 (1)

EQ 4.2 (1)

EQ 4.4 (1) NOTE:

ALL DIM’S INCH [MM]

ILLUSTRATION FOR REF ONLY AND NTS

oPeration & Maintenance technical inForMation / Product ProPerties installation warranty

Technical Data Sheet Model #3413-25

Use grab bar as template to mark mounting holes locations and pre-drill holes. Install bar using three (3) #10 self-threading flat head or oval head screws (by others) or other fastener system (by others) to suit conditions for each flange. Appropriate anchoring and backing must be provided in accordance with local building codes or as specified on Architects Plans prior to wall finishing. For compliance with 2010 ADA Accessibility Standards install unit so that the top of the grab bar is 33" [840] minimum Above Finished Floor (AFF) to 36" [915] maximum AFF. Anchors are available from ASI and must be specified separately for each grab bar style scheduled (see 3900 series).

Toilet Paper Holder Option -25 Grab Bar Configurations https://americanspecialties.com/wp-content/uploads/grabbarconfig.pdf

Manufacturer reserves the right to make changes to the design, dimensions or functionality of the product without formal notice.

Swing-up Grab Bar is lowered manually to horizontal position for support and raised for departure. Tension control prevents grab bar from dropping from the vertical position. Balance tension is adjustable by owner by tightening or loosening the clamp bolt. It is the owner’s responsibility to ensure continued safe operation by performing periodic inspection and effecting any adjustment or repairs required as usage may loosen tension over time. Bumper provides positive bar stop at top rest position. Plastic tube cap closes end of bottom tube and provides smooth solid contact with back plate.

One (1) Year from date of Invoice

American Specialties, Inc. | 441 Saw Mill River Road, Yonkers, NY 10701 | (914) 476-9000 | www.americanspecialties.com Model:

CSI:

#3413-25 10 28 13 Toilet Accessories

Issued: 11/1/2021 Revised: 5/31/2023 Page:

Revision:

ASI grab bars are designed to meet and exceed 2010 ADA Accessibility Standards and ANSI A117.1 that fabricated product shall be of adequate strength to support a load in excess of 250 pounds (113.4 kg). Mounting to the wall is a critical part of the system to meet this requirement. The fastener system must be adequately sized to withstand the shear, tension or pullout, and torsion loads generated by the maximum loading.

Property Value Dimensions

Construction

18 gauge tubing with 1-1/4" Outside Diameter [Ø32] / 30" [762] Length

Surface Mounted

R3

Type 304 Stainless Steel - Satin Finish 18 gauge tubing with 1-1/4" Outside Diameter [Ø32]

Mounting

Capacity

File details come from the government source that posted it. Updated .