About this file

This document contains phasing plans and construction documents for the renovation of Ward 1B at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The plans detail a phased approach to the construction work that maintains at least 15 active patient rooms at all times, with no more than 5 patient rooms temporarily out of commission on any given floor to allow for work on vertical services. Infection control risk assessments and barriers will be required during construction. The plans provide examples of phasing sequences and note areas that will require careful coordination with the facility to address shutdowns or gain access to support spaces. The related federal contract opportunity is solicitation number 36C24923R0114 for project number 626A4-19-101 to renovate Ward 1B at the specified VA Medical Center location. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9.

View the file

Other files

File Type Posted
36C24923R0114 0003.docx DOCX document
E-EI-01 - PARTIAL ELECTRICAL RISER DIAGRAM - DEMOLITION.pdf PDF
119437-Alvin C. York VAMC Renovate Ward 1B - Revision 1 - Electrical Narrative.pdf PDF
Government Answers to Industry Questions.pdf PDF
283100.pdf PDF
275223.pdf PDF
Bradley_GrabBar_8370-107.pdf PDF
Ward 1B - Revision 1.pdf PDF
Renovate Ward 1B Pre-Proposal Sign in Sheet - 07-06-2023.pdf PDF
E-EI-02 - PARTIAL ELECTRICAL RISER DIAGRAM - NEW WORK.pdf PDF
Bradley_GrabBar_8370-108.pdf PDF
General Decision Number TN20230187 06-30-2023 Rutherford County TN.pdf PDF
ASI 3413-25.pdf PDF
36C24923R0114 0002.docx DOCX document
GAMCO 125SwingUpTP.pdf PDF
Interior Wall Type Legend.pdf PDF
SUBCONTRACTOR INFORMATION AND CONSENT FORM.docx DOCX document
36C24923R0114 0001.docx DOCX document
MECH BINDER.pdf PDF
Ward 1B - Specs - Vol. 2.pdf PDF
GD Number TN20230187 05-12-2023.pdf PDF
GI 01-02 - CONSTRUCTION STAGING PLAN.pdf PDF
GI 03-01 - SECOND FLOOR ICRA PLAN.pdf PDF
GI 00-01 - COVER SHEET.pdf PDF
GI 01-10 - WALL TYPE DETAILS.pdf PDF
Price Schedule Project 626A4-19-101 Renovate Ward 1B.xlsx XLSX spreadsheet
GI 04-02 - LEAD PAINT AND TRANSITE PANELS.pdf PDF
36C24923R0114.docx DOCX document
General Conditions Breakout.xlsx XLSX spreadsheet
WARD 1B - ARCH BINDER.pdf PDF
GI 01-20 - ACCESSIBILITY DETAILS.pdf PDF
RFI Form.docx DOCX document
GI 04-01 - ACM DUCT WORK AND ACM PIPE INSULATION.pdf PDF
Performance Relevancy Survey Form - 626A4-19-101 Renovate Ward 1B.docx DOCX document
Ward 1B - Specs - Vol. 1.pdf PDF
VN 01-00 - PATIENT LIFT VENDOR DRAWINGS.pdf PDF
ELECTRICAL BINDER.pdf PDF
PLUMBING BINDER.pdf PDF
GI 01-01 - GENERAL DATA.pdf PDF
TECH BINDER.pdf PDF
WARD 1B - GENERAL.pdf PDF
WARD 1B - INTERIORS .pdf PDF
Calculation of Self Performed Work.docx DOCX document
GI 02-01 - THIRD FLOOR LIFE SAFETY PLAN - OVERALL.pdf PDF
AD 01-01 - THIRD FLOOR DEMOLITION PLAN - OVERALL.pdf PDF
Contractor EMR Certification Form.docx DOCX document
FP BINDER.pdf PDF
GI 03-02 - THIRD FLOOR ICRA PLAN.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLEAN UTILITY

SOILED UT.

PT. ROOM

PT. ROOM

PT. ROOM

PT. ROOM

ELEC.

STAFF TLT.STAIR

PT. ISO ROOM

PT. ROOM

PT. ROOM

WORK RM

ANTE

OFFICE

RESIDENTS RM.

MECH.

PT. ROOM

PT. ROOM

STOR. ROOM MEDS

SUPPLY ROOM

ELEC.

NOURISHMENT

CHUTE

IT

COMM

CONSULT

PT. ROOM PT. ROOM

PT. ROOM

PT. ROOM

MECH

OFFICE

RESIDENTS

ROOM

STAIR

PT. ROOM

PT. ROOM

PT. ROOM

WORK ROOM

CLEAN UTILITY

SOILED UTILITY

PT. ROOM

PT. ROOM

PT. ROOM

PT. ROOM

HAC ELEC.

STAFF TLT

NURSE WK.

NURSE STATION

SOCIAL WORK

WAITING ROOM

STAIRS

CHASE

LOCKER RM.

RETHERM

CONF.

STAFF TLT.

CORRID

STAFF BREAK

EXAMPLE #1

EXAMPLE LEGEND

EXAMPLE #2

EXAMPLE #3

EXAMPLE #4

EXAMPLE #5

EXAMPLE #6

ISO ROOM

PAT. TLT.

PRIVATE ROOM

PRIVATE ROOM

PRIVATE ROOM

BARI PRIVATE

ROOM

BARIATRIC

PATIENT TOILET

PRIVATE ROOM

PRIVATE ROOM

PANTRY

SERVING

KITCHEN

DINING/DAY

ROOM

LAUNDRY CLEAN SUPPLY

RETHERMCHUTE

EQUIP STORAGE

INPATIENT

REHAB

STAFF LOUNGE

STAFF LOCKERS

CHAIR ALCOVE

FAM. LOUNGE

CONSULT

FAM/PUB. TLT.

REC.THR. STOR.

TEAM ROOM

DATA

CLEAN LINEN

NOURISH

ST. TLT.

HAC.

SOILED HOLD

ELEC.

CLEAN UTILITY

HAC

WOUND CART

STOR.SUB NS.

PRIVATE ROOM

PRIVATE ROOM

ISO ROOM

CLEAN UTILITY

PAT. TLT.

ELEC.

EQUIP STOR.

TEAM WORKCLEAN LINEN

SOILED HOLD

BARI PRIVATE

ROOM

BARI. TLT.

NOURISHMENT

PAT. TLT.

PAT. TLT.

STAFF TLT.

PRIVATE ROOM

PAT. TLT.

PAT. TLT.

PAT. TLT.

PRIVATE ROOM

PAT. TLT.

PRIVATE ROOM

PRIVATE ROOM

PRIVATE ROOM

PAT. TLT.

PAT. TLT.

PAT. TLT.

PAT. TLT.

TEAM WORK

ROOM

SUB N.S.

CHARGE NURSE

NURSE STATION

SOCIAL WORKER

DIRTY

EMPTY CYL.

STOR.

FULL CYL. STOR.

ANTE

NURSE

MANAGER

PAT. TLT.

PAT. TLT.

ANTE

MEDS

COMM

STAFF TLT.

PRIVATE ROOM PRIVATE ROOM

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

VENDING

PAT. TLT.

PAT. TLT.

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

STAIR 1

STAIR 2

STAIR 3

EXISTING RISER

ELEV.

ELEV.

CHASE

CHASE

CHASE

CHASE

THE INTENT WITH THIS PLAN IS TO SHOW

HOW THE AREAS BETWEEN THE SECOND

FLOOR AND THRID FLOOR ALIGN

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2019

TLC No.:

www.tlc-engineers.com

118626

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C U s e rs \a tr a y lo r\ D o c u m e n ts

\M b o ro V

A W a rd b

R e n o a tr a y lo r2 X

N D

H .r v t

/1

/2

:5

:4

P

M

04-14-2023

626A4-19-101

GI 05.01

AE RENOVATE WARD 1BPHASING PLANS

Author

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

1 SECOND FLOOR PLAN - PHASING PLAN

0 8' 16' 32'4'

2 03 THIRD FLOOR PLAN - PHASING PLAN

0 8' 16' 32'4'

GENERAL NOTE:

1. THE PHASING PLAN IS NOTED AS EXAMPLES TO GIVE THE CONTRACTOR AN

UNDERSTANDING OF HOW THE PHASING FOR THE PROJECT NEEDS TO BE

ADDRESSED. WHILE THEY ARE LISTED BY NUMBER THESE EXAMPLES CAN BE

CONDUCTED IN ANY SEQUENCE AS DEEMED NECESSARY FOR THE MOST EFFECIENT

PROCESS POSSIBLE.

2. IN GENERAL 5 PATIENT ROOMS AT ONE TIME ON THE FLOOR BELOW WILL BE ABLE

TO BE TEMPORARLY OUT OF COMMISSION TO WORK ON VERTICAL SERVICES, THERE

MUST BE AT LEAST 15 ACTIVE PATIENT ROOMS AT ALL TIMES.

3. ALL ROOMS THAT ARE BEING WORKED ON SHALL BE PROTECTED FROM DAMAGE

AS BEST AS POSSIBILE. MOST OF THE WORK WILL TAKE PLACE IN THE CEILING,

HOWEVER DAMAGE TO ANY OTHER PART OF THE ROOM MUST BE REPARIED.

PROTECT EXISTING CEILING TILES, TILES THAT ARE DAMAGED OR BROKEN MUST BE

REPLACED TO THE ORIGINAL STATE.

4. CAREFUL COORDINATION WITH THE FACILITY MUST TAKE PLACE TO ADDRESS ANY

SHUTDOWNS THAT COULD EFFECT AREAS OUTSIDE OF THE DESIGNATED EXAMLE

ZONE.

5. IF SUPPORT SPACE INSIDE OF A DESIGNATED EXAMPLE ZONE IS SERVING

ANOTHER EXAMPLE ZONE COORDINATE SPECIFIC TIMES WITH THE FACILITY TO GAIN

ACCESS TO THIS SPACE.

6. ICRA BARRIERS MUST BE USED TO CLOSE OFF EACH AREA THAT IS BEING WORKED

ON TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM INFILTRATING OCCUPIED

SPACE. BARRIERS SHALL BE INSTALLED AND SEALED ALONG WITH STICKY MATS AND

ANY OTHER INFECTION CONTROL ITEMS. IN SOME INSTANCES ICRA BARRIERS MAY

BE REQUIRED PER ROOM.

7. WORK IN THE CONNECTING CORRIDORS, ELEVATOR LOBBY AND NURSE STATION

SHALL BE CAREFULLY COORDINATED WITH THE FACILITY AND STAFF. THE NEED TO

WORK IN THESE AREAS SHALL BE EVALUATED ON A AS NEEDED BASIS. ELEVATOR

ACCESS SHALL BE MAINTAINED AT ALL TIMES

No. Date Description

Sheets
GI 05.01 - PHASING PLANS

File details come from the government source that posted it. Updated .