MECH BINDER.pdf
PDF 16 MB Posted
- Attached to
- Z2DA--626A4-19-101 - Renovate Ward 1B at the Alvin C. York VA Medical Center, Murfreesboro, TN 37129
- Solicitation number
- 36C24923R0114
About this file
This document provides details on a federal contract opportunity to renovate Ward 1B at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The solicitation number is 36C24923R0114 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The opportunity type is for a solicitation to renovate Ward 1B at the specified VA medical center location. Products or services required include general construction and renovation work for Ward 1B. The response due date and anticipated award date are not provided in this document.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLEAN UTILITY
SOILED UT.
PT. ROOM
PT. ROOM
PT. ROOM
PT. ROOM
ELEC.
STAFF TLT.STAIR
PT. ISO ROOM
PT. ROOM
PT. ROOM
WORK RM
ANTE
OFFICE
RESIDENTS RM.
MECH.
PT. ROOM
PT. ROOM
STOR. ROOM MEDS
SUPPLY ROOM
ELEC.
NOURISHMENT
CHUTE
IT
COMM
CONSULT
PT. ROOM PT. ROOM
PT. ROOM
PT. ROOM
MECH
OFFICE
RESIDENTS
ROOM
STAIR
PT. ROOM
PT. ROOM
PT. ROOM
WORK ROOM
CLEAN UTILITY
SOILED UTILITY
PT. ROOM
PT. ROOM
PT. ROOM
PT. ROOM
HAC ELEC.
STAFF TLT
NURSE WK.
NURSE STATION
SOCIAL WORK
WAITING ROOM
STAIRS
CHASE
LOCKER RM.
RETHERM
CONF.
STAFF TLT.
CORRID
STAFF BREAK
EXAMPLE #1
EXAMPLE LEGEND
EXAMPLE #2
EXAMPLE #3
EXAMPLE #4
EXAMPLE #5
EXAMPLE #6
ISO ROOM
PAT. TLT.
PRIVATE ROOM
PRIVATE ROOM
PRIVATE ROOM
BARI PRIVATE
ROOM
BARIATRIC
PATIENT TOILET
PRIVATE ROOM
PRIVATE ROOM
PANTRY
SERVING
KITCHEN
DINING/DAY
ROOM
LAUNDRY CLEAN SUPPLY
RETHERMCHUTE
EQUIP STORAGE
INPATIENT
REHAB
STAFF LOUNGE
STAFF LOCKERS
CHAIR ALCOVE
FAM. LOUNGE
CONSULT
FAM/PUB. TLT.
REC.THR. STOR.
TEAM ROOM
DATA
CLEAN LINEN
NOURISH
ST. TLT.
HAC.
SOILED HOLD
ELEC.
CLEAN UTILITY
HAC
WOUND CART
STOR.SUB NS.
PRIVATE ROOM
PRIVATE ROOM
ISO ROOM
CLEAN UTILITY
PAT. TLT.
ELEC.
EQUIP STOR.
TEAM WORKCLEAN LINEN
SOILED HOLD
BARI PRIVATE
ROOM
BARI. TLT.
NOURISHMENT
PAT. TLT.
PAT. TLT.
STAFF TLT.
PRIVATE ROOM
PAT. TLT.
PAT. TLT.
PAT. TLT.
PRIVATE ROOM
PAT. TLT.
PRIVATE ROOM
PRIVATE ROOM
PRIVATE ROOM
PAT. TLT.
PAT. TLT.
PAT. TLT.
PAT. TLT.
TEAM WORK
ROOM
SUB N.S.
CHARGE NURSE
NURSE STATION
SOCIAL WORKER
DIRTY
EMPTY CYL.
STOR.
FULL CYL. STOR.
ANTE
NURSE
MANAGER
PAT. TLT.
PAT. TLT.
ANTE
MEDS
COMM
STAFF TLT.
PRIVATE ROOM PRIVATE ROOM
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
VENDING
PAT. TLT.
PAT. TLT.
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
STAIR 1
STAIR 2
STAIR 3
EXISTING RISER
ELEV.
ELEV.
CHASE
CHASE
CHASE
CHASE
THE INTENT WITH THIS PLAN IS TO SHOW
HOW THE AREAS BETWEEN THE SECOND
FLOOR AND THRID FLOOR ALIGN
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2019
TLC No.:
www.tlc-engineers.com
118626
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C U s e rs \a tr a y lo r\ D o c u m e n ts
\M b o ro V
A W a rd b
R e n o a tr a y lo r2 X
N D
H .r v t
/1
/2
:5
:4
P
M
04-14-2023
626A4-19-101
GI 05.01
AE RENOVATE WARD 1BPHASING PLANS
Author
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 SECOND FLOOR PLAN - PHASING PLAN
0 8' 16' 32'4'
2 03 THIRD FLOOR PLAN - PHASING PLAN
0 8' 16' 32'4'
GENERAL NOTE:
1. THE PHASING PLAN IS NOTED AS EXAMPLES TO GIVE THE CONTRACTOR AN
UNDERSTANDING OF HOW THE PHASING FOR THE PROJECT NEEDS TO BE
ADDRESSED. WHILE THEY ARE LISTED BY NUMBER THESE EXAMPLES CAN BE
CONDUCTED IN ANY SEQUENCE AS DEEMED NECESSARY FOR THE MOST EFFECIENT
PROCESS POSSIBLE.
2. IN GENERAL 5 PATIENT ROOMS AT ONE TIME ON THE FLOOR BELOW WILL BE ABLE
TO BE TEMPORARLY OUT OF COMMISSION TO WORK ON VERTICAL SERVICES, THERE
MUST BE AT LEAST 15 ACTIVE PATIENT ROOMS AT ALL TIMES.
3. ALL ROOMS THAT ARE BEING WORKED ON SHALL BE PROTECTED FROM DAMAGE
AS BEST AS POSSIBILE. MOST OF THE WORK WILL TAKE PLACE IN THE CEILING,
HOWEVER DAMAGE TO ANY OTHER PART OF THE ROOM MUST BE REPARIED.
PROTECT EXISTING CEILING TILES, TILES THAT ARE DAMAGED OR BROKEN MUST BE
REPLACED TO THE ORIGINAL STATE.
4. CAREFUL COORDINATION WITH THE FACILITY MUST TAKE PLACE TO ADDRESS ANY
SHUTDOWNS THAT COULD EFFECT AREAS OUTSIDE OF THE DESIGNATED EXAMLE
ZONE.
5. IF SUPPORT SPACE INSIDE OF A DESIGNATED EXAMPLE ZONE IS SERVING
ANOTHER EXAMPLE ZONE COORDINATE SPECIFIC TIMES WITH THE FACILITY TO GAIN
ACCESS TO THIS SPACE.
6. ICRA BARRIERS MUST BE USED TO CLOSE OFF EACH AREA THAT IS BEING WORKED
ON TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM INFILTRATING OCCUPIED
SPACE. BARRIERS SHALL BE INSTALLED AND SEALED ALONG WITH STICKY MATS AND
ANY OTHER INFECTION CONTROL ITEMS. IN SOME INSTANCES ICRA BARRIERS MAY
BE REQUIRED PER ROOM.
7. WORK IN THE CONNECTING CORRIDORS, ELEVATOR LOBBY AND NURSE STATION
SHALL BE CAREFULLY COORDINATED WITH THE FACILITY AND STAFF. THE NEED TO
WORK IN THESE AREAS SHALL BE EVALUATED ON A AS NEEDED BASIS. ELEVATOR
ACCESS SHALL BE MAINTAINED AT ALL TIMES
No. Date Description jim.elder Rectangle jim.elder Typewritten Text 06-13-2023 jim.elder Rectangle jim.elder Snapshot jim.elder Rectangle jim.elder Snapshot
U C c
GENERAL NOTES
1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A
FURRED CHASE OR ABOVE HARD SUSPENDED CEILING, OR ACOUSTICAL CEILING.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED.
DUCT SIZES ARE NET INSIDE DIMENSIONS.
3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS,
DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE FURNISHED AND
INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS. COORDINATE LOCATION WITH
4. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM, TERMINAL
UNITS, FILTERS, COILS, ETC. LOSS FOR FILTERS SHALL BE FOR FILTERS AT 50% LOADING.
5. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO EQUIPMENT, SEE STANDARD
EQUIPMENT DETAILS.
6. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES.
7. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE TO
PROVIDE COUNTER FLOW BETWEEN WATER AND AIR.
8. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING
DIFFUSERS, REGISTERS, AND GRILLES.
MECHANICAL INSTALLATION AND DEMONSTRATE ACCESS TO EQUIPMENT SERVED.
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
M
BD
P
M
TS
SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTION
SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION
SYMBOL DESCRIPTION
24x12
24x12
-EXISTING FIRE DAMPER TO REMAIN
-EXISTING FIRE & SMOKE DAMPER TO REMAIN
-PACKAGED TERMINAL AIR CONDITIONER
(PTAC)
-HYDRONIC REHEAT COIL
-FLAT OVAL DUCT
(WITH ACCESS PANEL)
(WITH ACCESS PANEL)
-ELECTRIC DUCT HEATER
(W/ PANEL CLEARANCE)FM
-MANUAL BALANCING DAMPER
-AIR FLOW MEASURING STATION
-MOTOR OPERATED CONTROL DAMPER (MOD)
-FIRE & SMOKE DAMPER
-FIRE DAMPER
-FLEXIBLE CONNECTION
-ACCESS DOORS, VERTICAL OR HORIZONTAL
-INLINE CENTRIFUGAL FAN
-STAINLESS STEEL DUCTWORK
-DOOR GRILLE
-UNDERCUT DOOR
SA-1 -SOUND ATTENUATOR
-SPIN-IN TAKE-OFF
-DUCT ELBOW UP THROUGH ROOF OR SLAB ABOVE
-RECTANGLE-TO-ROUND TAKE-OFF
DNUP
-TRANSITION, SQUARE TO ROUND
UP W/IN FLOORDOWN
-CEILING EXHAUST
-CEILING RETURN
24x12
-STANDARD BRANCH TAKE-OFF
-RADIUS ELBOW
-TRANSITION, ECCENTRIC
-FLEXIBLE DUCT
-CHANGE OF ELEVATION
-DUCT ELBOW, NEGATIVE PRESSURE, RETURN
-DUCT ELBOW, EXHAUST
DIMENSION INDICATES SIDE TO WHICH ARROW IS POINTING
-DUCT ELBOW, POSITIVE PRESSURE (SUPPLY), FIRST
-NEW DUCTWORK, FIRST DIMENSION IS SIDE SHOWN -TRANSITION, CONCENTRIC
-SQUARE THROAT ELBOW
W/TURNING VANES
-RECTANGULAR/ROUND BRANCH TAKE-OFF
OR ROUND/ROUND BRANCH TAKE-OFF
-SQUARE THROAT TEE
-RADIUS TEE
-ROUND DIFFUSER
-SUPPLY REGISTER OR GRILLE
-RETURN/EXHAUST REGISTER OR GRILLE
(VERTICAL MOUNT, SIDEWALL)
(VERTICAL MOUNT, SIDEWALL)
-EXISTING DUCTWORK TO REMAIN
-EXISTING DUCTWORK TO BE REMOVED
(CEILING DIFFUSERS ARE 4-WAY THROW UNO)
-CEILING DIFFUSER, ROUND NECK
-CEILING DIFFUSER, RECTANGULAR OR
SQUARE NECK (CEILING DIFFUSERS
ARE 4-WAY THROW UNO)
M-1
-TEMPERATURE SENSOR
-MOTORIZED CONTROL DAMPER
-HUMIDISTAT/HUMIDITY SENSOR
-THERMOSTAT/TEMPERATURE SENSOR
-REVISION REFERENCE
-DETAIL REFERENCE: TOP-DETAIL#,
BOTTOM-DRAWING# SHOWN ON
-PRESSURE SENSOR
-DUCT SMOKE DETECTOR
-CONNECT TO EXISTING
-DEMOLISH TO POINT INDICATED FF -FINAL FILTERS
DDC -DIRECT DIGITAL CONTROLS
PRS -PRESSURE REDUCING STATION
SP -STATIC PRESSURE
-CFM (CUBIC FEET PER MINUTE)
P -CHANGE IN PRESSURE
CV -CONSTANT AIR VOLUME
-ROOFTOP AIR HANDLING UNITRTU
RS/L -REFRIGERANT SUCTION & LIQUID LINES
h
-OUTSIDE AIR LOUVEROAL
-VARIABLE AIR VOLUMEVAV
-SUPPLY AIRSA
-ROOFTOP HEAT PUMPRHP
-REHEAT COILRHC
-REVOLUTIONS PER MINUTERPM
-RETURN AIRRA
-POLYVINYL CHLORIDE PIPEPVC
-PSI GAUGEPSIG
-POUNDS PER SQUARE INCHPSI
-PRESSURE REDUCING VALVEPRV
-OUTSIDE AIROA
-NOT TO SCALENTS
-NORMALLY OPENNO
-NORMALLY CLOSEDNC
-LINEAR DIFFUSERLD
-LEAVING WATER TEMPERATURELWT
-LEAVING AIR TEMPERATURELAT
-GALLONS PER MINUTEGPM
-FEET PER MINUTE
-FIRE DAMPER
-FAN COIL UNIT
-ENTERING WATER TEMPERATURE
-ENTERING AIR TEMPERATURE
-DOWN
-CONDENSING UNIT
-CUBIC FEET PER MINUTE
-CHANGE IN TEMPERATURE
-COOLING TOWER
-CEILING DIFFUSER
-CENTER LINE
-BRITISH THERMAL UNIT
-BRAKE HORSEPOWER
-BOTTOM OF PIPE
-ACCESS PANEL
-ABOVE FINISHED FLOOR
FPM
FD
FCU
EWT
EAT
DN
CU
CFM
T
CT
CD
BTU
BOP
BHP
AP
AFF
-AIR HANDLING UNITAHU
MBH -THOUSAND BTUs PER HOUR
AFD -ADJUSTABLE FREQUENCY DRIVE
ESP -EXTERNAL STATIC PRESSURE
KW -KILOWATT
MCA -MINIMUM CIRCUIT AMPS
MOCP -MAXIMUM OVER CURRENT PROTECTION
UNO
TSP -TOTAL STATIC PRESSURE
-VOLTS/PHASEV/PH
VFD -VARIABLE FREQUENCY DRIVE
-UNLESS NOTED OTHERWISE
FLA -FULL LOAD AMPS
-CONTROL VALVE
-45° PIPE RISE (R) / DROP (D)
-CONDENSER WATER SUPPLY
-CONDENSER WATER RETURN
-CHILLED WATER SUPPLY
-CHILLED WATER RETURN
-CONDENSATE
-HOT WATER RETURN
-HOT WATER SUPPLY
-REFRIGERANT LIQUID
-REFRIGERANT SUCTION
-VALVE ON RISER
-CAP
-CONNECTION, BOTTOM
-CONNECTION, TOP
-COUPLING
-ELBOW, 90°
-ELBOW, 45°
-ELBOW, TURNED DOWN
-ELBOW, TURNED UP
-TEE, OUTLET DOWN
-TEE, OUTLET UP
CWS
CWR
CHWS
CHWR
RL
RS
-FLOW SWITCH
-CHECK VALVE
-PSI REG.
-SOLENOID VALVE
-STRAINER
-GAS COCK
-BUTTERFLY VALVE
-CALIBRATING BALANCING VALVE
-BALL VALVE
-GATE VALVE
-UNION
PC -PUMPED CONDENSATE
DD
-HIGH PRESSURE STEAM SUPPLY
-LOW PRESSURE STEAM SUPPLY
-MEDIUM PRESSURE STEAM SUPPLY
CR -CONDENSATE RETURN
-SLOPE DIRECTION (DOWN)
-FLEX CONNECTION
-O.S.&Y. GATE VALVE
-THREE-WAY MODULATING CONTROL VALVE
-THERMOMETER
- P-TRAP
-TWO-WAY CHECK VALVE
EQUIP.
-MANUAL VENT
-PRESSURE GAUGE
-RELIEF VALVE
-FLOW METER
-WATER METER
-INLINE PUMP
-INLINE PUMP
-NEGATIVE RELATIVE PRESSURE
-POSITIVE RELATIVE PRESSURE
-NEUTRAL RELATIVE PRESSURE
-HIGH PRESSURE STEAM RETURN
-LOW PRESSURE STEAM RETURN
-MEDIUM PRESSURE STEAM RETURN
-BACKDRAFT DAMPER
MOD -MOTOR OPERATED CONTROL DAMPER (MOD)
-PACKAGED TERMINAL AIR CONDITIONERPTAC
-PIPE ANCHORS
-CONCENTRIC REDUCER
-ECCENTRIC REDUCER
-STEAM TRAP
-FLOW DIRECTION
-SHEET NOTE CALLOUT
-SHEET NOTE CALLOUT
-SHEET NOTE CALLOUT
-EXHAUST DUCT UP THROUGH SLAB TO
-CENTRIFUGAL EXHAUST FAN ON ROOF
-CEILING MOUNTED ACCESS DOOR
-RECTANGULAR DUCT SECTION UP, EXHAUST
-RECTANGULAR DUCT SECTION UP,
-RECTANGULAR DUCT SECTION UP, POSITIVE PRESSURE,
-ROUND DUCT SECTION UP
-FLAT OVAL DUCT SECTION UP
SUPPLY OR OUTSIDE AIR
NEGATIVE PRESSURE, RETURN
FAN ON ROOF ABOVE
-ABOVE FINISHED ROOFAFR
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
VOLUME WITH ELECTRIC HEAT
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
VOLUME, FAN POWERED
VOLUME, FAN POWERED, WITH ELECTRIC
HEAT
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
12x8
HVAC GENERAL NOTESHVAC ABBREVIATIONSHVAC SYMBOL LEGEND
HVAC PIPING SYMBOL LEGEND
8Ø10x8
24x12
12x8
HPS
MPS
LPS
CD
HWR
HWS
HPR
MPR
LPR
H
VOLUME WITH ELECTRIC HEAT
S
MV
FM
M
1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED
DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED
FOR EQUIPMENT FURNISHED.
2. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR
FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS
SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO
OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST. FOR PROJECTS
INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE
BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND
ELECTRICAL CONDUIT.
3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE
SMACNA HVAC DUCT CONSTRUCTION STANDARD.
4. SEE SPECIFICATIONS FOR GAUGES, THICKNESS, BRACING, REQUIREMENTS, ETC., OF DUCTWORK.
5. PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS.
6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT
FURNISHED.
7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL
REFLECTED CEILING PLANS AND EQUIPMENT OF ALL TRADES.
8. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" TO
54" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER
EQUIPMENT, FURNITURE, AND DOOR SWINGS.
9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE
ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.
10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.
11. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE
PAINTED FLAT BLACK.
12. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.
13. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR
PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED.
14. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR
OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT.
15. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL
TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.
16. PROVIDE CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR-MOUNTED EQUIPMENT. REFER TO
SPECIFICATIONS FOR DETAILED REQUIREMENTS.
17. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS
AND OTHER AIR DISTRIBUTION DEVICES.
18. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, AIR
HANDLING UNITS, AND FAN COIL UNITS.
19. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE
CONNECTED.
20. INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO SERVICES SHALL
NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND
PROPER COORDINATION WITH OTHER TRADES. PRE-WORK SHALL BE PERFORMED TO MAKE THE
SHUTDOWN PERIOD AS BRIEF AS POSSIBLE.
21. ALL EQUIPMENT, DUCTWORK, ETC., TO BE REMOVED SHALL BE DISPOSED OF LEGALLY.
22. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS.
23. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 25' CLEAR FROM ALL PLUMBING VENTS AND
EXHAUST AIR DISCHARGE LOCATIONS.
24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.
25. WATER PRESSURE DROPS THROUGH COIL CONTROL VALVES SHALL NOT EXCEED 5 PSI.
26. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED
FULL SIZE TO THE NEAREST PLUMBING DRAIN.
27. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS. PROVIDE MANUAL AIR
VENTS AT ALL HIGH POINTS IN CHILLED WATER AND HOT WATER PIPING.
28. PIPING, DUCTWORK, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO ELECTRICAL SWITCHBOARDS, PANELBOARDS, DISTRIBUTION BOARDS, OR MOTOR CONTROL CENTERS SHALL NOT BE INSTALLED WITHIN THE REQUIRED SPACE FOR WORKING CLEARANCES OR DEDICATED SPACES OF THE ELECTRICAL EQUIPMENT, EXTENDING IN FRONT OF AND FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC-110.26.
T
200A
RHC-1-1
AHU-1
VTU-1-1
CTU - CONSTANT TERMINAL UNIT
VARIABLE/CONSTANT AIR VOLUME TERMINAL UNITS
VTU - VARIABLE TERMINAL UNIT
PTU - PARALLEL TERMINAL UNIT
STU - SERIES TERMINAL UNIT
-AIR HANDLING UNIT
-REHEAT COIL
-AIR DISTRIBUTION DEVICE
HVAC EQUIPMENT TAGS
TAG
CFM
AHU NUMBER
AHU NUMBER COIL NUMBER
AHU NUMBER
TERMINAL NUMBER
TERMINAL UNIT TYPE
75 UC -UNDERCUT DOOR, 75 CFM
T/H -TEMPERATURE & HUMIDITY MONITOR
DP -DIFFERENTIAL PRESSURE SENSOR
GI 05.01 PHASING PLANS
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:2
A
M
06-13-2023
626A4-19-101
M-MH-01
AE RENOVATE WARD 1BLEGENDS, NOTES, AND SYMBOLS
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
MECHANICAL SHEET INDEX
SHEET DESCRIPTION
M-MH-01 LEGENDS, NOTES, AND SYMBOLS
M-MD-01 PARTIAL THIRD FLOOR PLAN - PART A - DUCT DEMO
M-MD-02 PARTIAL THIRD FLOOR PLAN - PART B - DUCT DEMO
M-MD-03 PARTIAL THIRD FLOOR PLAN - PART C - DUCT DEMO
M-MD-04 PARTIAL THIRD FLOOR PLAN - PART A - PIPE DEMO
M-MD-05 PARTIAL THIRD FLOOR PLAN - PART B - PIPE DEMO
M-MD-06 PARTIAL THIRD FLOOR PLAN - PART C - PIPE DEMO
M-MH-13 PARTIAL ATTIC PLAN - PART B - DUCT DEMO
M-MH-14 PARTIAL ATTIC PLAN - PART C - DUCT DEMO
M-MH-02 PARTIAL THIRD FLOOR PLAN - PART A - DUCT NEW WORK
M-MH-03 PARTIAL THIRD FLOOR PLAN - PART B - DUCT NEW WORK
M-MH-04 PARTIAL THIRD FLOOR PLAN - PART C - DUCT NEW WORK
M-MH-05 PARTIAL ATTIC PLAN - PART B - DUCT NEW WORK
M-MH-06 PARTIAL ATTIC PLAN - PART C - DUCT NEW WORK
M-MP-01 PARTIAL THIRD FLOOR PLAN - PART A - PIPE NEW WORK
M-MP-02 PARTIAL THIRD FLOOR PLAN - PART B - PIPE NEW WORK
M-MP-03 PARTIAL THIRD FLOOR PLAN - PART C - PIPE NEW WORK
M-MH-07 SCHEDULES
M-MH-08 SCHEDULES
M-MH-09 MECHANICAL DETAILS
M-MH-10 MECHANICAL DETAILS
M-MH-11 MECHANICAL DETAILS
M-MH-12 MECHANICAL DETAILS
M-MI-01 MECHANICAL CONTROLS
M-MI-02 MECHANICAL CONTROLS
No. Date Description
X3 X3
X4
X9
X10
X11
X12
X13
X14
XI XJ
XK
XL XM XN XO
XP
XQ XR XS
X6.1
X7.1
X12.1
X12.2 X12.3
X8
X5
X6
X7 M
A T
C H
L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
T
T
A 220
A 125
A 120
A 285
A 55
B 75
A 125A 125
A 125 A 125
B 400
A 100
A 100
A 100
A 100
A 155
B 195
A 55
A 145
A 115
A 370
B 370
A 155
A 205
A 155
A 350
A 350
B 405
A 275
B 400
A 220
A 190
A 235
B 500
190235
B 140
DEMOLITION NOTES:
1. REMOVE EXISTING UNDER WINDOW WALL MOUNTED HEATERS AND STEAM PIPING AND CAP OFF EXISTING PIPING DOWN AT THE SLAB OR AS LOW AS POSSIBLE. STEAM PIPING HAS ASBESTOS SO ALLOW
FOR ASBESTOS REMOVAL ON STEAM PIPING ROUTED TO WALL MOUNTED HEATERS. WALLS TO BE
PATCHED TO MATCH EXISTING, REFER TO ARCHITECTURAL FOR OTHER REQUIREMENTS REGUARDING
WALL PATCHING.
2. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. EXISTING EQUIPMENT, STRUCTURE, DUCTWORK, ETC. LOCATED ON DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA. CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT
AND ENGINEER PRIOR TO BEGINNING DEMOLITION. START UP OF DEMOLITION SHALL SIGNIFY
CONTRACTORS ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL
REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT.
3. CONTRACTOR SHALL PERFORM A PRE-BID SURVEY TO FIELD-VERIFY AND COORDINATE ALL DIMENSIONS PROIR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, ELECTRUCAL CONDUIT, AND PNEUMATIC TUBING. THE COST OF REROUTING DUCTWORK OR PIPING DUE
TO CONFLICTS WITH EXISTING CONDITIONS SHALL BE PAID BY THE CONTRACTOR.
4. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO THE OTHER SPACES. ALL MECHANICAL SYSTEMS THAT RUN INTO THE SPACE BUT DO NOT SERVE ANYTHING SHALL BE REMOVED BACK TO WHERE THEY ENTER THE SPACE TO FREE-UP VALUABLE CLREANCE FOR
NEW DUCT AND PIPING.
5. CONTRACTOR SHALL PROVIDE MECHANICAL WORK FOR PHASING AS REQUIRED OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECTURAL PHASING PLAN, TEMPORARY MECHANICAL SERVICES SHALL BE
PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDED TO REMAIN ACTIVE.
6. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF.
7. CONTRACTOR SHALL REMOVE EXISTING THERMOSTATS IN RENOVATION SPACE. REMOVED
THERMOSTATS SHALL BE DISPOSED OF.
8. PROPERLY REMOVE AND DISPOSE OF ALL INDICATED EXISTING TO BE REMOVED HVAC DUCTWORK AND
AIR DISTRIBUTION DEVICES.
9. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, THERMOSTATS, CONDUIT, ETC… TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY
EXISTING OPENINGS IN RATED WALLS OR FLOORS.
10. PROVIDE TEMPORARY NEGATIVE AIR MACHINES FOR CONSTRUCTION AREA. MAINTAIN A NEGATIVE PRESSURE IN THE AREA RELATIVE TO THE ADJACENT SPACES AT A MINIMUM OF -0.03” W.C. PROVIDE SHEET ROCK TYPE WALL BARRIER PARTITIONS WITH AIR TIGHT OR LOW LEAKAGE CONSTRUCTION ACCESS. FAN TO BE EQUIVALENT TO HEPA-AIRE PAS1200HC, 800 CFM, ¼ HP, 120 VOLT. PROVIDE AS MANY MACHINES AS NECESSARY TO MAINTAIN NEGATIVE PRESSURE REQUIREMENT IN RENOVATION SPACE.
REFERENCE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION CONCERNING ICRA.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:4
A
M
06-13-2023
626A4-19-101
M-MD-01
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART A -
DUCT DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
1 PARTIAL WARD 1B FLOOR PLAN - PART A - DUCT DEMO
X1X1
X2 X2
X3 X3
X4
X9
X10
X11
X0 X0
XB XC XD XE XF XG XH XI XJ
XK
X6.1
X7.1
X12.2 X12.3
X8
XA
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
A 210
B 420
B 530
A 265A 265
A 135
A 265 A 265
B 525
A 155 A 155
A 155
A 165
A 229
A 210
A 60 B 425
A 60
B 75
A 185
A 185
A 50
B 65
A 240
A 65
A 260
A 70
B 90
A 60
B 195
A 215
A 220 A 125
A 120
B 140 285
A 285
A 55
B 75
A 220
A 235
A 190
190235B 440
A 385
B 155
B 160
A 225
B 90
A 55
A 195 A 135
A 195
A 175
A 220
A 110
B 440
A 110
A 110
A 110
B 355
A 185
A 185 B 180
A 150
A 230
A 230
B 445
A 195
A 250
A 195
REMOVE VERTICAL PORTION OF
EXHAUST DUCTWORK THRU THIS FLOOR
AND OFFSET TO NEW CHASE SHOWN ON
PART B NEW WORK SHEET, FIELD VERIFY
EXACT LOCATION AND SIZE
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:5
A
M
06-13-2023
626A4-19-101
M-MD-02
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART B -
DUCT DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
1 PARTIAL WARD 1B FLOOR PLAN - PART B - DUCT DEMO
DEMOLITION NOTES:
1. REMOVE EXISTING UNDER WINDOW WALL MOUNTED HEATERS AND PIPING AND CAP OFF EXISTING PIPING DOWN AT FLOOR SLAB OR AS LOW AS POSSIBLE. STEAM PIPING HAS ASBESTOS SO ALLOW FOR ASBESTOS REMOVAL ON STEAM PIPING ROUTED TO WALL MOUNTED HEATERS. WALLS TO BE PATCHED TO MATCH EXISTING, REFER TO
ARCHITECTURAL FOR OTHER REQUIREMENTS REGUARDING WALL PATCHING.
2. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. EXISTING EQUIPMENT, STRUCTURE, DUCTWORK, ETC.
LOCATED ON DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA.
CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT AND ENGINEER PRIOR TO BEGINNING DEMOLITION. START UP OF DEMOLITION SHALL SIGNIFY CONTRACTORS ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED DEMOLITION WHETHER SHOWN
ON THE PLANS OR NOT.
3. CONTRACTOR SHALL PERFORM A PRE-BID SURVEY TO FIELD-VERIFY AND COORDINATE ALL DIMENSIONS PROIR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, ELECTRUCAL CONDUIT, AND PNEUMATIC TUBING. THE COST OF REROUTING DUCTWORK OR PIPING DUE TO CONFLICTS WITH EXISTING
CONDITIONS SHALL BE PAID BY THE CONTRACTOR.
4. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO THE OTHER SPACES.
ALL MECHANICAL SYSTEMS THAT RUN INTO THE SPACE BUT DO NOT SERVE ANYTHING SHALL BE REMOVED BACK TO WHERE THEY ENTER THE SPACE TO FREE-UP VALUABLE CLREANCE FOR NEW DUCT AND PIPING.
5. CONTRACTOR SHALL PROVIDE MECHANICAL WORK FOR PHASING AS REQUIRED OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECTURAL PHASING PLAN, TEMPORARY MECHANICAL SERVICES SHALL BE
PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDED TO REMAIN ACTIVE.
6. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF.
7. CONTRACTOR SHALL REMOVE EXISTING THERMOSTATS IN RENOVATION SPACE. REMOVED THERMOSTATS SHALL
BE DISPOSED OF.
8. PROPERLY REMOVE AND DISPOSE OF ALL INDICATED EXISTING TO BE REMOVED HVAC DUCTWORK AND AIR
DISTRIBUTION DEVICES.
9. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, THERMOSTATS, CONDUIT, ETC… TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY EXISTING OPENINGS
IN RATED WALLS OR FLOORS.
10. PROVIDE TEMPORARY NEGATIVE AIR MACHINES FOR CONSTRUCTION AREA. MAINTAIN A NEGATIVE PRESSURE IN THE AREA RELATIVE TO THE ADJACENT SPACES AT A MINIMUM OF -0.03” W.C. PROVIDE SHEET ROCK TYPE WALL BARRIER PARTITIONS WITH AIR TIGHT OR LOW LEAKAGE CONSTRUCTION ACCESS. FAN TO BE EQUIVALENT TO HEPA-AIRE PAS1200HC, 800 CFM, ¼ HP, 120 VOLT. PROVIDE AS MANY MACHINES AS NECESSARY TO MAINTAIN NEGATIVE PRESSURE REQUIREMENT IN RENOVATION SPACE. REFERENCE ARCHITECTURAL PLANS FOR
ADDITIONAL INFORMATION CONCERNING ICRA.
X3 X3
X4
X9
X10
X11
X0 X0
XQ XR XS XT XU XV XW XX XY
X6.1
X7.1
X12.2
XZ
X8
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
DEMOLITION NOTES:
1. REMOVE EXISTING UNDER WINDOW WALL MOUNTED HEATERS AND PIPING AND CAP OFF EXISTING PIPING DOWN AT THE FLOOR SLAB OR AS LOW AS POSSIBLE. STEAM PIPING HAS ASBESTOS SO ALLOW FOR ASBESTOS REMOVAL ON STEAM PIPING ROUTED TO WALL MOUNTED HEATERS. WALLS TO BE PATCHED TO MATCH EXISTING, REFER TO ARCHITECTURAL FOR OTHER REQUIREMENTS REGUARDING WALL PATCHING.
2. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. EXISTING EQUIPMENT, STRUCTURE, DUCTWORK, ETC.
LOCATED ON DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA.
CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT AND ENGINEER PRIOR TO BEGINNING DEMOLITION. START UP OF DEMOLITION SHALL SIGNIFY CONTRACTORS ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED DEMOLITION WHETHER SHOWN
ON THE PLANS OR NOT.
3. CONTRACTOR SHALL PERFORM A PRE-BID SURVEY TO FIELD-VERIFY AND COORDINATE ALL DIMENSIONS PROIR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, ELECTRUCAL CONDUIT, AND PNEUMATIC TUBING. THE COST OF REROUTING DUCTWORK OR PIPING DUE TO CONFLICTS WITH EXISTING
CONDITIONS SHALL BE PAID BY THE CONTRACTOR.
4. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO THE OTHER SPACES.
ALL MECHANICAL SYSTEMS THAT RUN INTO THE SPACE BUT DO NOT SERVE ANYTHING SHALL BE REMOVED BACK TO WHERE THEY ENTER THE SPACE TO FREE-UP VALUABLE CLREANCE FOR NEW DUCT AND PIPING.
5. CONTRACTOR SHALL PROVIDE MECHANICAL WORK FOR PHASING AS REQUIRED OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECTURAL PHASING PLAN, TEMPORARY MECHANICAL SERVICES SHALL BE
PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDED TO REMAIN ACTIVE.
6. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF.
7. CONTRACTOR SHALL REMOVE EXISTING THERMOSTATS IN RENOVATION SPACE. REMOVED THERMOSTATS
SHALL BE DISPOSED OF.
8. PROPERLY REMOVE AND DISPOSE OF ALL INDICATED EXISTING TO BE REMOVED HVAC DUCTWORK AND AIR
DISTRIBUTION DEVICES.
9. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, THERMOSTATS, CONDUIT, ETC… TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY EXISTING
OPENINGS IN RATED WALLS OR FLOORS.
10. PROVIDE TEMPORARY NEGATIVE AIR MACHINES FOR CONSTRUCTION AREA. MAINTAIN A NEGATIVE PRESSURE IN THE AREA RELATIVE TO THE ADJACENT SPACES AT A MINIMUM OF -0.03” W.C. PROVIDE SHEET ROCK TYPE WALL BARRIER PARTITIONS WITH AIR TIGHT OR LOW LEAKAGE CONSTRUCTION ACCESS. FAN TO BE EQUIVALENT TO HEPA-AIRE PAS1200HC, 800 CFM, ¼ HP, 120 VOLT. PROVIDE AS MANY MACHINES AS NECESSARY TO MAINTAIN NEGATIVE PRESSURE REQUIREMENT IN RENOVATION SPACE. REFERENCE ARCHITECTURAL PLANS FOR
ADDITIONAL INFORMATION CONCERNING ICRA.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:0
A
M
06-13-2023
626A4-19-101
M-MD-03
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART C -
DUCT DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 PARTIAL WARD 1B FLOOR PLAN - PART C - DUCT DEMO
0 2' 4' 8'1'
X3 X3
X4
X9
X10
X11
X12
X13
X14
XI XJ
XK
XL XM XN XO
XP
XQ XR XS
X6.1
X7.1
X12.1
X12.2 X12.3
X8
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
T T
T
T T T
T
T
T
T
T
T
T
T
T
T
T
T
T
REMOVE ALL INDOOR REFRIGERANT
PIPING ASSOCATED WITH RETHERM
UNITS. SEE NEW FLOOR PLAN FOR
NEW LOCATION OF RETHERM UNIT
REMOVE ALL HOT WATER SUPPLY AND RETURN BACK TO
CHASE, REMOVE ALL REHEAT BOXES, REMOVE ALL
THERMOSTATS. (TYPICAL FOR PART A, B, & C.)
THIS PORTION OF HOT WATER PIPING NEEDS TO
REMAIN IN PLACE TO SERVE THE 4TH FLOOR REHEAT
BOXES UNTIL CONTRACTOR IS READY TO INSTALL
NEW PIPING TO MINIMIZE THE TIME THAT THE
4TH FLOOR WILL BE WITHOUT HEATING.
EXISTING 1-1/4" HOT WATER
SUPPLY AND RETURN UP
TO 4TH FLOOR REHEAT BOXES
SEE PART B FOR CONTINUATION
SEE PART C FOR CONTINUATION
THERE IS APPARENTLY SOME CHILLED WATER
SUPPLY & RETURN UP INTO THE 4TH FLOOR ATTIC
SERVING AN EXISTING AHU. PIPING MAY BE
ROUTED UP ON EITHER SIDE OF CORRIDOR AND
NEEDS TO REMAIN. SEE PICTURE # 1 THIS SHEET
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:0
A
M
06-13-2023
626A4-19-101
M-MD-04
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART A -
PIPE DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
1 PARTIAL WARD 1B FLOOR PLAN - PART A - PIPE DEMO
PICTURE # 1
X3 X3
X4
X9
X10
X11
X0 X0
XB XC XD XE XF XG XH XI XJ
XK
X6.1
X7.1
X12.2 X12.3
X8
XA
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
T
T T
T
T
T T
T T
T
T
T
T
T
T
T
T
T
T T
T
T
T
T
T
EXISTING 2" CHILLED WATER
SUPPLY AND RETURN PIPING
UP TO EXISTING AHU IN ATTIC,
FIELD VERIFY EXACT LOCATION
EXISTING 1-1/4" HOT WATER
SUPPLY AND RETURN UP
TO 4TH FLOOR REHEAT BOXES
THIS PORTION OF HOT WATER PIPING NEEDS TO
REMAIN IN PLACE TO SERVE THE 4TH FLOOR REHEAT
BOXES UNTIL CONTRACTOR IS READY TO INSTALL
NEW PIPING TO MINIMIZE THE TIME THAT THE
4TH FLOOR WILL BE WITHOUT HEATING.
SEE PART A FOR
CONTINUATION
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:1
A
M
06-13-2023
626A4-19-101
M-MD-05
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART B -
PIPE DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
1 PARTIAL WARD 1B FLOOR PLAN - PART B - PIPE DEMO
X3 X3
X4
X9
X10
X11
X0 X0
XQ XR XS XT XU XV XW XX XY
X6.1
X7.1
X12.2
XZ
X8
X5
X6
X7
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
A
T T
T
T T
T
T
T
T
T
T
T
T
T T
T
T
T
T T
TSEE PART A FOR
CONTINUATION
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:1
A
M
06-13-2023
626A4-19-101
M-MD-06
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART C -
PIPE DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
0 2' 4' 8'1'
1 PARTIAL WARD 1B FLOOR PLAN - PART C - PIPE DEMO
X3 X3
X4
X9
X10
X11
X0 X0
XB XC XD XE XF XG XH XIXJ
XK
X6.1
X7.1
X12.2 X12.3
X8
XA
X5 X5
X6
X7
EXISTING AHU-1 IN ATTIC
EXISTING RETURN FAN
EXISTING EXHAUST FAN
EXISTING EXHAUST FANS
SERVING WARD 1A
ISOLATION ROOM
EXISTING EXHAUST FAN
REMOVE EXISTING
EXHAUST FAN AND
DUCTWORK, SEE
PICTURE # 2 THIS SHEET
REMOVE EXISTING
FILTER
REMOVE EXISTING
DUCTWORK AND CAP
OPENING, SEE PICTURE
# 1 THIS SHEET
EXISTING ELECTRICAL
EXISTING SMALL DUCT
DOWN THRU FLOOR. IT
IS NOT KNOWN WHERE
THIS DUCT IS ROUTED
BELOW, IT WILL NEED
TO BE OFF-SET IN THE
CEILING BELOW. SEE
PICTURE # 5 THIS
SHEET.
EXISTING COPPER VENT
LINES DOWN THRU
FLOOR, SEE PICTURE#4
ON THIS SHEET.
REMOVE EXISTING AIR
VALVE AND DUCTWORK
ELECTRICAL
EXISTING RETURN DUCT
EXISTING BIO-HAZARD
DUCT DOWN THRU
FLOOR
PICTURE # 1
PICTURE # 2
PICTURE # 3
REMOVE EXHAUST DUCTWORK,
SEE PICTURE # 3 THIS SHEET
PICTURE # 4PICTURE # 5
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:4
A
M
06-13-2023
626A4-19-101
M-MH-13
AE RENOVATE WARD 1B
PARTIAL ATTIC PLAN - PART B - DUCT
DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 FOURTH FLOOR - PART B - DUCT DEMO
RQI
(OFOI)
RQI
(OFOI)
RQI
(OFOI)
X1
X2
X3
X4
X9
X0
XQ XR XS XT XU XV XW XX XY
X6.1
X7.1
XZ
X8
X5
X6
X7
EXHSTING AHU-2 IN ATTIC
REMOVE EXISTING
EXHAUST FAN AND
ASSOCIATED DUCTWORK.
SEE PICTURE # 3 ON THIS
SHEET.
EXHSTING RETURN FAN IN ATTIC
EXHSTING EXHAUST FAN
EXHAUST FANS SERVING WARD 1A
ISOLATION ROOM
REMOVE EXISTING EXHAUST FAN AND
ASSOCIATED DUCTWORK,
SEE PICTURE # 2 THIS SHEET
EXHAUST FILTER SERVING WARD
1A ISOLATION ROOM
PATCH EXISTING OPENING
REMOVE EXISTING EXHAUST FILTER
AND ASSOCIATED DUCTWORK,
SEE PICTURE # 1 THIS SHEET.
EXISTING OPENING THRU FLOOR
TO BE PATCHED
REMOVE EXISTING
EXHAUST DUCT AND
BLANK-OFF LOUVER
DO NOT PASS THRU ANU PORTION
OF AHU UNLESS IT IS UPSTREAM
OF FILTER SECTION
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:4
A
M
06-13-2023
626A4-19-101
M-MH-14
AE RENOVATE WARD 1B
PARTIAL ATTIC PLAN - PART C - DUCT
DEMO
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 FOURTH FLOOR - PART C - DUCT DEMO
0 2' 4' 8'1'
PICTURE # 1
PICTURE # 2
PICTURE # 3
FEC
F E
C
CR CR
CR
C R
X3 X3
X4 X4
X9 X9X11
X12
X13
X14
XI XJ
XK
XL XM XN XO
XP
XQ XR XS
X6.1 X6.1
X7.1 X7.1
X12.1
X12.2
X12.3
X8 X8
X5 X5
X6 X6
X7 X7
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
M A
T C
H L
IN
E
P A
R T
B
PANTRY
B338A
SERVING KITCHEN
B338
DINING/DAY ROOM
B337
RETHERM
B361
LAUNDRY
B359 CLEAN SUPPLY
B363
CHUTE
B360
NURSE STATION
B336
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
EQUIP STORAGE
B301
INPATIENT REHAB
B303
STAFF LOUNGE
B304
STAFF LOCKERS
B304B
CHAIR ALCOVE
B305
FAM. LOUNGE
B307
CONSULT
B310
FAM/PUB. TLT.
B308
REC.THR. STOR.
B309
TEAM ROOM
B332
DATA
B335
PAT. TLT.
B331A
PRIVATE ROOM
B331
CHARGE NURSE
B336A
SOCIAL WORKER
B302
DIRTY
B362
NURSE MANAGER
B333
MEDS
B336B
COMM
B334
STAFF TLT.
B304A
CORRIDOR
B300
CORRIDOR
B370
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
CHASE
VENDING
B300A
EXISTING RISER
B370A
ELEV.
ELEV.
CHASE
FD
FD
STAIR 1
(NOT IN CONTRACT)
(N.I.C)
(N.I.C)
0"
+1 3/4"+1 3/4"
+1 3/4"+1 3/4"
0"
+2"
+2 1/4"
+1 5/8"
+1 5/8"
B301A
STAIR 1
B306
A 220
A 220
A 200
A 215
A 310
A 230
A 225
A 30
A 225
A 230
A 280
A 280
A 225
A 230
A 230 A 230
A 230
A 350
A 250
A 100
A 60
A 150
A 240
A 250
A 250
A 40
A 300
A 150
A 260 V1-19
B 350
B 600
V1-20
B 460 A 460
B 100 A 70 B 50
V1-21
B 455 x1
V1-22
B 510
V2-25
V1-23
B 75
V1-24
B 150
B 375
B 75
B 240
V1-26
V1-28
V1-27
B 465
V2-24
B 440
V2-23
B 300
B 230
V2-21 V2-20
B 310
B 350
A 200
V2-19
V2-18B 75 x1 x1 ø ø
14ø
16x12
24x1428x14
28x1432x14 x1
16x12 x1
2 16 x1 x1
30x12 x1 x1
30x14
30x14
25/12 28/12
24x1030x1236x12 x1
8x8
10x10 UP TO EF-1
ON ROOF
4" ALUMINUM DRYER VENT OUT
THRU WALL WITH WEATHER CAP
AND BACKDRAFT DAMPER
V1-25
B 200 x1
10ø 6x
12x8 8ø
6ø 6ø
STRUCTURAL CEILING STEPS DOWN SOME BETWEEN
COLUMN LINE "XJ" AND COLUMN LINE "XQ".
CONTRACTOR TO OFFSET DUCTS AND PIPING TO
ACCOMMODATE STEP DOWN.
DDC
PANEL
12x10
B 50
18x18 x1
V2-22
AC-1 AC-2
CU-2
CU-1
18/12
EXISTING EXHAUST DUCT
FROM BELOW UP TO
ATTIC
12x10
24x14
B 825 16x12 x1
8x10
/1
18/12 ø
6x6 x1
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:2
A
M
06-13-2023
626A4-19-101
M-MH-02
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART A -
DUCT NEW WORK
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 PARTIAL WARD 1B FLOOR PLAN - PART A - DUCT NEW WORK
F E
C
F E
C
FEC FEC
FEC
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
PRIVATE ROOM
B349
PRIVATE ROOM
B348
ISO ROOM
B347
CLEAN UTILITY
B346
ELEC.
B344
EQUIP STOR.
B343
CLEAN LINEN
B351
SOILED HOLD
B352
BARI PRIVATE
ROOM
B355
BARI. TLT.
B355A
NOURISHMENT
B356
SUB NS.
B358
HAC
B357
STAFF TLT.
B358A
PANTRY
B338A
SERVING
KITCHEN
B338
DINING/DAY
ROOM
B337
RETHERM
B361
LAUNDRY
B359
CLEAN SUPPLY
B363
CHUTE
B360
X1X1
X2 X2
X3 X3
X4
X9
X10 X10
X11
X0 X0
XB XC XD XE XF XG XH XI XJ
XK
X6.1
X7.1
X12.2
X12.3
X8
XA
X5
X6
X7
CORRIDOR
B374
CORRIDOR
B375
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
B
TEAM WORK
B341
DIRTY
B362
ANTE
B347A
PRIVATE ROOM
B354
PRIVATE ROOM
B353
PAT. TLT.
B354A
PAT. TLT.
B353A
CHASE
PRIVATE ROOM
B339
PRIVATE ROOM
B340
FD
TYP
D N
FD
FD
FD FD
FD
FD
FD
FD
FD
FDPRIVATE ROOM
B350
PAT. TLT.
B349A
PAT. TLT.
B340A PAT. TLT.
B339A
PAT. TLT.
B350A
PAT. TLT.
B348A
PAT. TLT.
B347B
CORRIDOR
B376
STAIR 2
CHASE
B338B
(NOT IN CONTRACT)
FD
SHOWER TYPE 1
SHOWER TYPE 2
SHOWER TYPE 2
SHOWER TYPE 1
SHOWER TYPE 3
SHOWER TYPE 4
SHOWER TYPE 5
SHOWER TYPE 1
SHOWER TYPE 2
FD
B342
STAIR 2
B345
FD
FD
FD
FD
FD FD
FD
A 340
A 260 A 260
A 40
A 30
A 205
A 205
A 190
A 185
A 90
A 70A 100
A 235 A 235
A 230
A 260 A 260
A 30
A 40
A 200
A 200
A 310
A 40
A 150
A 275
A 250
A 250
A 40
A 275 A 30
A 240
A 265
A 275 A 30
A 40
A 170 A 275
A 175
A 110
A 275 A 100
A 75
A 235
GENERAL NOTES:
1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A FURRED CHASE OR ABOVE
HARD SUSPENDED CEILING, OR ACOUSTICAL CEILING.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. DUCT SIZES ARE NET
INSIDE DIMENSIONS.
3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE FURNISHED AND INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS. COORDINATE LOCATION WITH MECHANICAL INSTALLATION AND
DEMONSTRATE ACCESS TO EQUIPMENT SERVED.
4. FOR TYPICAL WATER PIPING CONNECTIONS TO EQUIPMENT, SEE STANDARD EQUIPMENT DETAILS.
5. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE CFM's, REFER TO AIR DISTRIBUTION
DEVICE SCHEDULE FOR ADDITIONAL INFORMATION .
6. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE TO PROVIDE COUNTER FLOW
BETWEEN WATER AND AIR.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING DIFFUSERS, REGISTERS, AND GRILLES.
A 225
A 280
A 460
B 340
V1-13
B 420
B 110
B 360
B 80 B 110
B 305
V1-10
V1-9
B 140
B 730
B 150
B 730
B 230
B 240
B 730
B 350
V1-18
V1-17 V1-15
V1-16
C 330
D 330
V1-2
B 160
AV1-1
B 125
B 600
B 110
B 80
B 190 V1-5
B 215
V1-6
B 80
B 110
B 275
V1-7
V1-4
B 150
B 80
B 110
A 230
B 455
V1-19
V1-20
B 460
B 100
A 70
B 50
B 600
V1-21
B 510
V1-22 x1
10x10
V1-14
20x12
15/12 ø
20/12 16x14 32x14 x1
24x1424x1014x8
16x10 x1
30x14 20x12 x8
12x12
18x16
36x16
/1 x1 x1
42x14
22/14
/1 ø x1 x1 x1
10ø x1
12x12
8x
6x x8
8x
10x10 x1
18x10
10x10
10x10 x8
12x8 x1
12x8 x1 x1
16x12 x1 x1
28x14
24x14
30x1236x12 24x10 x1 x1
12x10 x1
EV1-1
EV1-2
EXHAUST DUCTS FROM WARD
1A UP TO ATTIC
12x1210ø x1
12x10
8x8
V1-8
V1-1
V1-11 V1-12
V1-3
EXISTING EXHAUST DUCT DOWN FROM ATTIC
SPACE. REROUTE ABOVE CEILING AND ROUTE
DOWN IN NEW CHASE TO FLOOR BELOW.
REROUTE IN CEILING OF FLOOR BELOW TO
CONNECT BACK TO EXISTING DUCT. SIZE IS
ABOUT 18X18, FIELD VERIFY.
PROVIDE FD AT SLAB
STRUCTURAL CEILING STEPS DOWN ABOUT
1.5 FEET JUST LEFT OF COLUMN LINE "XB"
AND CONTINUES OVER TO COLUMN LINE "XA".
CONTRACTOR TO OFFSET DUCTS AND PIPING
TO ACCOMODATE
OFF-SET EXISTING EXHAUST DUCT
FROM ATTIC SPACE DOWN TO
FLOOR BELOW
12x10
B 50
CONTRACTOR TO ENSURE NO PART OF THE
FACE OF DIFFUSER INTERFEARS WITH THE
HOIST AND TRACK SYSTEM MOVEMENT.
(TYPICAL FOR DIFFUSERS MOUNTED ABOVE
TRACK AND HOIST SYSTEM)
12x6 12x10 x1
8x6
24x14 28x14
10ø
10ø
12x8
10x8
COORDINATE DIFFUSER AND GRILLE
LOCATIONS WITH BARIATRIC LIFT
VENDOR INSTALLATION PRIOR TO
ROUTING DUCT RUNOUTS SERVING
THESE.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
119437
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
PROJECT TEAM:
Office of
Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
KEYPLAN
MURFREESBORO, TN
615.370.8500
615.370.8530 hfrdesign.com
214 Centerview Drive Suite 300 Brentwood, TN 37027
BLDG 2
BLDG 1
BLDG 9
Phase
FULLY SPRINKLERED
C R e v it
L o c a ls
\1
-A lv in
C .Y o rk
V A
M C
R e n o v a te W a rd
B
M E
C H
R jim .e ld e r@ tl c -e n g
.c o m .r v t
/1
/2
:2
:4
A
M
06-13-2023
626A4-19-101
M-MH-03
AE RENOVATE WARD 1B
PARTIAL THIRD FLOOR PLAN - PART B -
DUCT NEW WORK
JE
HFR Project No: 2019056
100% CONSTRUCTION
DOCUMENTS
1 PARTIAL WARD 1B FLOOR PLAN - PART B - DUCT NEW WORK
FEC FEC
F E
C
F E
C
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
A
M A
T C
H L
IN
E
P A
R T
C
M A
T C
H L
IN
E
P A
R T
C
TEAM ROOM
B332
REC.THR. STOR.
B309
CONSULT
B310
FAM/PUB. TLT.
B308
PRIVATE ROOM
B331
PAT. TLT.
B331A
PAT. TLT.
B330A
PRIVATE ROOM
B330
TEAM WORK
ROOM
B329
WOUND CART
STOR.
B311B
ST. TLT.
B311A
CLEAN LINEN
B318
BARI PRIVATE
ROOM
B313
BARIATRIC
PATIENT TOILET
B313A
NOURISH
B312
CLEAN UTILITY
B320
ELEC.
B326
SOILED HOLD
B327
HAC.
B325
ISO ROOM
B321
PAT. TLT.
B322A
SUB N.S.
B311
X1X1
X2 X2
X3 X3
X4
X9
X10
X0 X0
XQ XR XS XT XU XV XW XX XY XZ
X8
X5
X6
X7
NURSE
MANAGER
B333
PAT. TLT.
B321B
PRIVATE ROOM
B322
EMPTY CYL.
STOR.
B317
FULL CYL. STOR.
B316
PAT. TLT.
B315A PAT. TLT.
B314A
ANTE
B321A
CORRIDOR
B371
CORRIDOR
B372
CORRIDOR
B373
PRIVATE ROOM
B314
PRIVATE ROOM
B315
FD
FD
FD
FD
FD
PRIVATE ROOM
B324
PRIVATE ROOM
B323
PAT. TLT.
B323A
PAT. TLT.
B324A
STAIR 3
FD
FD
FD
FD
(NOT IN CONTRACT)
FD
SHOWER TYPE 1
SHOWER TYPE 2
SHOWER TYPE 2
SHOWER TYPE 1
SHOWER TYPE 1
SHOWER TYPE 2
SHOWER TYPE 3
SHOWER TYPE 4
SHOWER TYPE 5
FD
STAIR 3
B319
CHASE
B328
FD
FD
FD
FD
FD
A 230
A 60
A 50
A 150
A 50
A 200
A 245
A 260
A 40
A
A 280
A 30
A 205
A 180
A 30
A 205
A 40
A 200
A 320
A 40
A 30
A 205
A 240
A 90
A 400
A 215A 215
A 215
A 215A 215
A 200
A 105
A 310A 200
A 30
A 40
A 310
A 245
A 205A 200
A 180
A 255
A 200
A 30
V2-19
V2-18 B 825
V2-17
B 240
B 110
B 80B 350
B 310
V2-20 V2-21
V2-9
V2-16
B 595
V2-8
B 230
B 110
C 50
V2-2
B 170
V2-1
AV2-1
EV2-2
EV2-1
B 125
B 110
B 600
V2-4
V2-5
B 230
B 310
V2-6
V2-7
B 110
B 80
B 80
B 330
B 50B 50
V2-11
V2-12
B 250
B 110 B 80
B 360 B 435
B 140
B 400
V2-14
V2-15 V2-13B 400 x1
23/12 20/12 15/12 x1
24x10 x1
14x1024x10
32x10
B 100
/1
20/12
/1
/1 x8 x8
8x x1 x1 x1
10ø
10x12 x1 x1
10x10
10x10 x1 x1
10x10
8x ø
14x…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .