About this file

This document provides details on a federal contract opportunity to renovate Ward 1B at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The solicitation number is 36C24923R0114 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The opportunity type is for a solicitation to renovate Ward 1B at the specified VA medical center location. Products or services required include general construction and renovation work for Ward 1B. The response due date and anticipated award date are not provided in this document.

View the file

Other files

File Type Posted
36C24923R0114 0003.docx DOCX document
E-EI-01 - PARTIAL ELECTRICAL RISER DIAGRAM - DEMOLITION.pdf PDF
119437-Alvin C. York VAMC Renovate Ward 1B - Revision 1 - Electrical Narrative.pdf PDF
Government Answers to Industry Questions.pdf PDF
283100.pdf PDF
275223.pdf PDF
Bradley_GrabBar_8370-107.pdf PDF
Ward 1B - Revision 1.pdf PDF
Renovate Ward 1B Pre-Proposal Sign in Sheet - 07-06-2023.pdf PDF
E-EI-02 - PARTIAL ELECTRICAL RISER DIAGRAM - NEW WORK.pdf PDF
Bradley_GrabBar_8370-108.pdf PDF
General Decision Number TN20230187 06-30-2023 Rutherford County TN.pdf PDF
ASI 3413-25.pdf PDF
36C24923R0114 0002.docx DOCX document
GAMCO 125SwingUpTP.pdf PDF
Interior Wall Type Legend.pdf PDF
SUBCONTRACTOR INFORMATION AND CONSENT FORM.docx DOCX document
36C24923R0114 0001.docx DOCX document
Ward 1B - Specs - Vol. 2.pdf PDF
GD Number TN20230187 05-12-2023.pdf PDF
GI 01-02 - CONSTRUCTION STAGING PLAN.pdf PDF
GI 03-01 - SECOND FLOOR ICRA PLAN.pdf PDF
GI 05-01 - PHASING PLANS.pdf PDF
GI 00-01 - COVER SHEET.pdf PDF
GI 01-10 - WALL TYPE DETAILS.pdf PDF
Price Schedule Project 626A4-19-101 Renovate Ward 1B.xlsx XLSX spreadsheet
GI 04-02 - LEAD PAINT AND TRANSITE PANELS.pdf PDF
36C24923R0114.docx DOCX document
General Conditions Breakout.xlsx XLSX spreadsheet
WARD 1B - ARCH BINDER.pdf PDF
GI 01-20 - ACCESSIBILITY DETAILS.pdf PDF
RFI Form.docx DOCX document
GI 04-01 - ACM DUCT WORK AND ACM PIPE INSULATION.pdf PDF
Performance Relevancy Survey Form - 626A4-19-101 Renovate Ward 1B.docx DOCX document
Ward 1B - Specs - Vol. 1.pdf PDF
VN 01-00 - PATIENT LIFT VENDOR DRAWINGS.pdf PDF
ELECTRICAL BINDER.pdf PDF
PLUMBING BINDER.pdf PDF
GI 01-01 - GENERAL DATA.pdf PDF
TECH BINDER.pdf PDF
WARD 1B - GENERAL.pdf PDF
WARD 1B - INTERIORS .pdf PDF
Calculation of Self Performed Work.docx DOCX document
GI 02-01 - THIRD FLOOR LIFE SAFETY PLAN - OVERALL.pdf PDF
AD 01-01 - THIRD FLOOR DEMOLITION PLAN - OVERALL.pdf PDF
Contractor EMR Certification Form.docx DOCX document
FP BINDER.pdf PDF
GI 03-02 - THIRD FLOOR ICRA PLAN.pdf PDF
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLEAN UTILITY

SOILED UT.

PT. ROOM

PT. ROOM

PT. ROOM

PT. ROOM

ELEC.

STAFF TLT.STAIR

PT. ISO ROOM

PT. ROOM

PT. ROOM

WORK RM

ANTE

OFFICE

RESIDENTS RM.

MECH.

PT. ROOM

PT. ROOM

STOR. ROOM MEDS

SUPPLY ROOM

ELEC.

NOURISHMENT

CHUTE

IT

COMM

CONSULT

PT. ROOM PT. ROOM

PT. ROOM

PT. ROOM

MECH

OFFICE

RESIDENTS

ROOM

STAIR

PT. ROOM

PT. ROOM

PT. ROOM

WORK ROOM

CLEAN UTILITY

SOILED UTILITY

PT. ROOM

PT. ROOM

PT. ROOM

PT. ROOM

HAC ELEC.

STAFF TLT

NURSE WK.

NURSE STATION

SOCIAL WORK

WAITING ROOM

STAIRS

CHASE

LOCKER RM.

RETHERM

CONF.

STAFF TLT.

CORRID

STAFF BREAK

EXAMPLE #1

EXAMPLE LEGEND

EXAMPLE #2

EXAMPLE #3

EXAMPLE #4

EXAMPLE #5

EXAMPLE #6

ISO ROOM

PAT. TLT.

PRIVATE ROOM

PRIVATE ROOM

PRIVATE ROOM

BARI PRIVATE

ROOM

BARIATRIC

PATIENT TOILET

PRIVATE ROOM

PRIVATE ROOM

PANTRY

SERVING

KITCHEN

DINING/DAY

ROOM

LAUNDRY CLEAN SUPPLY

RETHERMCHUTE

EQUIP STORAGE

INPATIENT

REHAB

STAFF LOUNGE

STAFF LOCKERS

CHAIR ALCOVE

FAM. LOUNGE

CONSULT

FAM/PUB. TLT.

REC.THR. STOR.

TEAM ROOM

DATA

CLEAN LINEN

NOURISH

ST. TLT.

HAC.

SOILED HOLD

ELEC.

CLEAN UTILITY

HAC

WOUND CART

STOR.SUB NS.

PRIVATE ROOM

PRIVATE ROOM

ISO ROOM

CLEAN UTILITY

PAT. TLT.

ELEC.

EQUIP STOR.

TEAM WORKCLEAN LINEN

SOILED HOLD

BARI PRIVATE

ROOM

BARI. TLT.

NOURISHMENT

PAT. TLT.

PAT. TLT.

STAFF TLT.

PRIVATE ROOM

PAT. TLT.

PAT. TLT.

PAT. TLT.

PRIVATE ROOM

PAT. TLT.

PRIVATE ROOM

PRIVATE ROOM

PRIVATE ROOM

PAT. TLT.

PAT. TLT.

PAT. TLT.

PAT. TLT.

TEAM WORK

ROOM

SUB N.S.

CHARGE NURSE

NURSE STATION

SOCIAL WORKER

DIRTY

EMPTY CYL.

STOR.

FULL CYL. STOR.

ANTE

NURSE

MANAGER

PAT. TLT.

PAT. TLT.

ANTE

MEDS

COMM

STAFF TLT.

PRIVATE ROOM PRIVATE ROOM

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

VENDING

PAT. TLT.

PAT. TLT.

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

STAIR 1

STAIR 2

STAIR 3

EXISTING RISER

ELEV.

ELEV.

CHASE

CHASE

CHASE

CHASE

THE INTENT WITH THIS PLAN IS TO SHOW

HOW THE AREAS BETWEEN THE SECOND

FLOOR AND THRID FLOOR ALIGN

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2019

TLC No.:

www.tlc-engineers.com

118626

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C U s e rs \a tr a y lo r\ D o c u m e n ts

\M b o ro V

A W a rd b

R e n o a tr a y lo r2 X

N D

H .r v t

/1

/2

:5

:4

P

M

04-14-2023

626A4-19-101

GI 05.01

AE RENOVATE WARD 1BPHASING PLANS

Author

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

1 SECOND FLOOR PLAN - PHASING PLAN

0 8' 16' 32'4'

2 03 THIRD FLOOR PLAN - PHASING PLAN

0 8' 16' 32'4'

GENERAL NOTE:

1. THE PHASING PLAN IS NOTED AS EXAMPLES TO GIVE THE CONTRACTOR AN

UNDERSTANDING OF HOW THE PHASING FOR THE PROJECT NEEDS TO BE

ADDRESSED. WHILE THEY ARE LISTED BY NUMBER THESE EXAMPLES CAN BE

CONDUCTED IN ANY SEQUENCE AS DEEMED NECESSARY FOR THE MOST EFFECIENT

PROCESS POSSIBLE.

2. IN GENERAL 5 PATIENT ROOMS AT ONE TIME ON THE FLOOR BELOW WILL BE ABLE

TO BE TEMPORARLY OUT OF COMMISSION TO WORK ON VERTICAL SERVICES, THERE

MUST BE AT LEAST 15 ACTIVE PATIENT ROOMS AT ALL TIMES.

3. ALL ROOMS THAT ARE BEING WORKED ON SHALL BE PROTECTED FROM DAMAGE

AS BEST AS POSSIBILE. MOST OF THE WORK WILL TAKE PLACE IN THE CEILING,

HOWEVER DAMAGE TO ANY OTHER PART OF THE ROOM MUST BE REPARIED.

PROTECT EXISTING CEILING TILES, TILES THAT ARE DAMAGED OR BROKEN MUST BE

REPLACED TO THE ORIGINAL STATE.

4. CAREFUL COORDINATION WITH THE FACILITY MUST TAKE PLACE TO ADDRESS ANY

SHUTDOWNS THAT COULD EFFECT AREAS OUTSIDE OF THE DESIGNATED EXAMLE

ZONE.

5. IF SUPPORT SPACE INSIDE OF A DESIGNATED EXAMPLE ZONE IS SERVING

ANOTHER EXAMPLE ZONE COORDINATE SPECIFIC TIMES WITH THE FACILITY TO GAIN

ACCESS TO THIS SPACE.

6. ICRA BARRIERS MUST BE USED TO CLOSE OFF EACH AREA THAT IS BEING WORKED

ON TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM INFILTRATING OCCUPIED

SPACE. BARRIERS SHALL BE INSTALLED AND SEALED ALONG WITH STICKY MATS AND

ANY OTHER INFECTION CONTROL ITEMS. IN SOME INSTANCES ICRA BARRIERS MAY

BE REQUIRED PER ROOM.

7. WORK IN THE CONNECTING CORRIDORS, ELEVATOR LOBBY AND NURSE STATION

SHALL BE CAREFULLY COORDINATED WITH THE FACILITY AND STAFF. THE NEED TO

WORK IN THESE AREAS SHALL BE EVALUATED ON A AS NEEDED BASIS. ELEVATOR

ACCESS SHALL BE MAINTAINED AT ALL TIMES

No. Date Description jim.elder Rectangle jim.elder Typewritten Text 06-13-2023 jim.elder Rectangle jim.elder Snapshot jim.elder Rectangle jim.elder Snapshot

U C c

GENERAL NOTES

1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A

FURRED CHASE OR ABOVE HARD SUSPENDED CEILING, OR ACOUSTICAL CEILING.

2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED.

DUCT SIZES ARE NET INSIDE DIMENSIONS.

3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS,

DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE FURNISHED AND

INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS. COORDINATE LOCATION WITH

4. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM, TERMINAL

UNITS, FILTERS, COILS, ETC. LOSS FOR FILTERS SHALL BE FOR FILTERS AT 50% LOADING.

5. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO EQUIPMENT, SEE STANDARD

EQUIPMENT DETAILS.

6. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES.

7. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE TO

PROVIDE COUNTER FLOW BETWEEN WATER AND AIR.

8. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING

DIFFUSERS, REGISTERS, AND GRILLES.

MECHANICAL INSTALLATION AND DEMONSTRATE ACCESS TO EQUIPMENT SERVED.

NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT

M

BD

P

M

TS

SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTION

SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION

SYMBOL DESCRIPTION

24x12

24x12

-EXISTING FIRE DAMPER TO REMAIN

-EXISTING FIRE & SMOKE DAMPER TO REMAIN

-PACKAGED TERMINAL AIR CONDITIONER

(PTAC)

-HYDRONIC REHEAT COIL

-FLAT OVAL DUCT

(WITH ACCESS PANEL)

(WITH ACCESS PANEL)

-ELECTRIC DUCT HEATER

(W/ PANEL CLEARANCE)FM

-MANUAL BALANCING DAMPER

-AIR FLOW MEASURING STATION

-MOTOR OPERATED CONTROL DAMPER (MOD)

-FIRE & SMOKE DAMPER

-FIRE DAMPER

-FLEXIBLE CONNECTION

-ACCESS DOORS, VERTICAL OR HORIZONTAL

-INLINE CENTRIFUGAL FAN

-STAINLESS STEEL DUCTWORK

-DOOR GRILLE

-UNDERCUT DOOR

SA-1 -SOUND ATTENUATOR

-SPIN-IN TAKE-OFF

-DUCT ELBOW UP THROUGH ROOF OR SLAB ABOVE

-RECTANGLE-TO-ROUND TAKE-OFF

DNUP

-TRANSITION, SQUARE TO ROUND

UP W/IN FLOORDOWN

-CEILING EXHAUST

-CEILING RETURN

24x12

-STANDARD BRANCH TAKE-OFF

-RADIUS ELBOW

-TRANSITION, ECCENTRIC

-FLEXIBLE DUCT

-CHANGE OF ELEVATION

-DUCT ELBOW, NEGATIVE PRESSURE, RETURN

-DUCT ELBOW, EXHAUST

DIMENSION INDICATES SIDE TO WHICH ARROW IS POINTING

-DUCT ELBOW, POSITIVE PRESSURE (SUPPLY), FIRST

-NEW DUCTWORK, FIRST DIMENSION IS SIDE SHOWN -TRANSITION, CONCENTRIC

-SQUARE THROAT ELBOW

W/TURNING VANES

-RECTANGULAR/ROUND BRANCH TAKE-OFF

OR ROUND/ROUND BRANCH TAKE-OFF

-SQUARE THROAT TEE

-RADIUS TEE

-ROUND DIFFUSER

-SUPPLY REGISTER OR GRILLE

-RETURN/EXHAUST REGISTER OR GRILLE

(VERTICAL MOUNT, SIDEWALL)

(VERTICAL MOUNT, SIDEWALL)

-EXISTING DUCTWORK TO REMAIN

-EXISTING DUCTWORK TO BE REMOVED

(CEILING DIFFUSERS ARE 4-WAY THROW UNO)

-CEILING DIFFUSER, ROUND NECK

-CEILING DIFFUSER, RECTANGULAR OR

SQUARE NECK (CEILING DIFFUSERS

ARE 4-WAY THROW UNO)

M-1

-TEMPERATURE SENSOR

-MOTORIZED CONTROL DAMPER

-HUMIDISTAT/HUMIDITY SENSOR

-THERMOSTAT/TEMPERATURE SENSOR

-REVISION REFERENCE

-DETAIL REFERENCE: TOP-DETAIL#,

BOTTOM-DRAWING# SHOWN ON

-PRESSURE SENSOR

-DUCT SMOKE DETECTOR

-CONNECT TO EXISTING

-DEMOLISH TO POINT INDICATED FF -FINAL FILTERS

DDC -DIRECT DIGITAL CONTROLS

PRS -PRESSURE REDUCING STATION

SP -STATIC PRESSURE

-CFM (CUBIC FEET PER MINUTE)

P -CHANGE IN PRESSURE

CV -CONSTANT AIR VOLUME

-ROOFTOP AIR HANDLING UNITRTU

RS/L -REFRIGERANT SUCTION & LIQUID LINES

h

-OUTSIDE AIR LOUVEROAL

-VARIABLE AIR VOLUMEVAV

-SUPPLY AIRSA

-ROOFTOP HEAT PUMPRHP

-REHEAT COILRHC

-REVOLUTIONS PER MINUTERPM

-RETURN AIRRA

-POLYVINYL CHLORIDE PIPEPVC

-PSI GAUGEPSIG

-POUNDS PER SQUARE INCHPSI

-PRESSURE REDUCING VALVEPRV

-OUTSIDE AIROA

-NOT TO SCALENTS

-NORMALLY OPENNO

-NORMALLY CLOSEDNC

-LINEAR DIFFUSERLD

-LEAVING WATER TEMPERATURELWT

-LEAVING AIR TEMPERATURELAT

-GALLONS PER MINUTEGPM

-FEET PER MINUTE

-FIRE DAMPER

-FAN COIL UNIT

-ENTERING WATER TEMPERATURE

-ENTERING AIR TEMPERATURE

-DOWN

-CONDENSING UNIT

-CUBIC FEET PER MINUTE

-CHANGE IN TEMPERATURE

-COOLING TOWER

-CEILING DIFFUSER

-CENTER LINE

-BRITISH THERMAL UNIT

-BRAKE HORSEPOWER

-BOTTOM OF PIPE

-ACCESS PANEL

-ABOVE FINISHED FLOOR

FPM

FD

FCU

EWT

EAT

DN

CU

CFM

T

CT

CD

BTU

BOP

BHP

AP

AFF

-AIR HANDLING UNITAHU

MBH -THOUSAND BTUs PER HOUR

AFD -ADJUSTABLE FREQUENCY DRIVE

ESP -EXTERNAL STATIC PRESSURE

KW -KILOWATT

MCA -MINIMUM CIRCUIT AMPS

MOCP -MAXIMUM OVER CURRENT PROTECTION

UNO

TSP -TOTAL STATIC PRESSURE

-VOLTS/PHASEV/PH

VFD -VARIABLE FREQUENCY DRIVE

-UNLESS NOTED OTHERWISE

FLA -FULL LOAD AMPS

-CONTROL VALVE

-45° PIPE RISE (R) / DROP (D)

-CONDENSER WATER SUPPLY

-CONDENSER WATER RETURN

-CHILLED WATER SUPPLY

-CHILLED WATER RETURN

-CONDENSATE

-HOT WATER RETURN

-HOT WATER SUPPLY

-REFRIGERANT LIQUID

-REFRIGERANT SUCTION

-VALVE ON RISER

-CAP

-CONNECTION, BOTTOM

-CONNECTION, TOP

-COUPLING

-ELBOW, 90°

-ELBOW, 45°

-ELBOW, TURNED DOWN

-ELBOW, TURNED UP

-TEE, OUTLET DOWN

-TEE, OUTLET UP

CWS

CWR

CHWS

CHWR

RL

RS

-FLOW SWITCH

-CHECK VALVE

-PSI REG.

-SOLENOID VALVE

-STRAINER

-GAS COCK

-BUTTERFLY VALVE

-CALIBRATING BALANCING VALVE

-BALL VALVE

-GATE VALVE

-UNION

PC -PUMPED CONDENSATE

DD

-HIGH PRESSURE STEAM SUPPLY

-LOW PRESSURE STEAM SUPPLY

-MEDIUM PRESSURE STEAM SUPPLY

CR -CONDENSATE RETURN

-SLOPE DIRECTION (DOWN)

-FLEX CONNECTION

-O.S.&Y. GATE VALVE

-THREE-WAY MODULATING CONTROL VALVE

-THERMOMETER

- P-TRAP

-TWO-WAY CHECK VALVE

EQUIP.

-MANUAL VENT

-PRESSURE GAUGE

-RELIEF VALVE

-FLOW METER

-WATER METER

-INLINE PUMP

-INLINE PUMP

-NEGATIVE RELATIVE PRESSURE

-POSITIVE RELATIVE PRESSURE

-NEUTRAL RELATIVE PRESSURE

-HIGH PRESSURE STEAM RETURN

-LOW PRESSURE STEAM RETURN

-MEDIUM PRESSURE STEAM RETURN

-BACKDRAFT DAMPER

MOD -MOTOR OPERATED CONTROL DAMPER (MOD)

-PACKAGED TERMINAL AIR CONDITIONERPTAC

-PIPE ANCHORS

-CONCENTRIC REDUCER

-ECCENTRIC REDUCER

-STEAM TRAP

-FLOW DIRECTION

-SHEET NOTE CALLOUT

-SHEET NOTE CALLOUT

-SHEET NOTE CALLOUT

-EXHAUST DUCT UP THROUGH SLAB TO

-CENTRIFUGAL EXHAUST FAN ON ROOF

-CEILING MOUNTED ACCESS DOOR

-RECTANGULAR DUCT SECTION UP, EXHAUST

-RECTANGULAR DUCT SECTION UP,

-RECTANGULAR DUCT SECTION UP, POSITIVE PRESSURE,

-ROUND DUCT SECTION UP

-FLAT OVAL DUCT SECTION UP

SUPPLY OR OUTSIDE AIR

NEGATIVE PRESSURE, RETURN

FAN ON ROOF ABOVE

-ABOVE FINISHED ROOFAFR

-TERMINAL UNIT, VARIABLE/CONSTANT AIR

VOLUME WITH ELECTRIC HEAT

-TERMINAL UNIT, VARIABLE/CONSTANT AIR

-TERMINAL UNIT, VARIABLE/CONSTANT AIR

VOLUME, FAN POWERED

VOLUME, FAN POWERED, WITH ELECTRIC

HEAT

-TERMINAL UNIT, VARIABLE/CONSTANT AIR

12x8

HVAC GENERAL NOTESHVAC ABBREVIATIONSHVAC SYMBOL LEGEND

HVAC PIPING SYMBOL LEGEND

8Ø10x8

24x12

12x8

HPS

MPS

LPS

CD

HWR

HWS

HPR

MPR

LPR

H

VOLUME WITH ELECTRIC HEAT

S

MV

FM

M

1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED

DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED

FOR EQUIPMENT FURNISHED.

2. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR

FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS

SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO

OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST. FOR PROJECTS

INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE

BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND

ELECTRICAL CONDUIT.

3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE

SMACNA HVAC DUCT CONSTRUCTION STANDARD.

4. SEE SPECIFICATIONS FOR GAUGES, THICKNESS, BRACING, REQUIREMENTS, ETC., OF DUCTWORK.

5. PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS.

6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT

FURNISHED.

7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL

REFLECTED CEILING PLANS AND EQUIPMENT OF ALL TRADES.

8. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" TO

54" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER

EQUIPMENT, FURNITURE, AND DOOR SWINGS.

9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE

ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.

10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.

11. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE

PAINTED FLAT BLACK.

12. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.

13. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR

PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED.

14. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR

OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT.

15. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL

TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.

16. PROVIDE CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR-MOUNTED EQUIPMENT. REFER TO

SPECIFICATIONS FOR DETAILED REQUIREMENTS.

17. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS

AND OTHER AIR DISTRIBUTION DEVICES.

18. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, AIR

HANDLING UNITS, AND FAN COIL UNITS.

19. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE

CONNECTED.

20. INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO SERVICES SHALL

NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND

PROPER COORDINATION WITH OTHER TRADES. PRE-WORK SHALL BE PERFORMED TO MAKE THE

SHUTDOWN PERIOD AS BRIEF AS POSSIBLE.

21. ALL EQUIPMENT, DUCTWORK, ETC., TO BE REMOVED SHALL BE DISPOSED OF LEGALLY.

22. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS.

23. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 25' CLEAR FROM ALL PLUMBING VENTS AND

EXHAUST AIR DISCHARGE LOCATIONS.

24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.

25. WATER PRESSURE DROPS THROUGH COIL CONTROL VALVES SHALL NOT EXCEED 5 PSI.

26. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED

FULL SIZE TO THE NEAREST PLUMBING DRAIN.

27. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS. PROVIDE MANUAL AIR

VENTS AT ALL HIGH POINTS IN CHILLED WATER AND HOT WATER PIPING.

28. PIPING, DUCTWORK, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO ELECTRICAL SWITCHBOARDS, PANELBOARDS, DISTRIBUTION BOARDS, OR MOTOR CONTROL CENTERS SHALL NOT BE INSTALLED WITHIN THE REQUIRED SPACE FOR WORKING CLEARANCES OR DEDICATED SPACES OF THE ELECTRICAL EQUIPMENT, EXTENDING IN FRONT OF AND FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC-110.26.

T

200A

RHC-1-1

AHU-1

VTU-1-1

CTU - CONSTANT TERMINAL UNIT

VARIABLE/CONSTANT AIR VOLUME TERMINAL UNITS

VTU - VARIABLE TERMINAL UNIT

PTU - PARALLEL TERMINAL UNIT

STU - SERIES TERMINAL UNIT

-AIR HANDLING UNIT

-REHEAT COIL

-AIR DISTRIBUTION DEVICE

HVAC EQUIPMENT TAGS

TAG

CFM

AHU NUMBER

AHU NUMBER COIL NUMBER

AHU NUMBER

TERMINAL NUMBER

TERMINAL UNIT TYPE

75 UC -UNDERCUT DOOR, 75 CFM

T/H -TEMPERATURE & HUMIDITY MONITOR

DP -DIFFERENTIAL PRESSURE SENSOR

GI 05.01 PHASING PLANS

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:2

A

M

06-13-2023

626A4-19-101

M-MH-01

AE RENOVATE WARD 1BLEGENDS, NOTES, AND SYMBOLS

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

MECHANICAL SHEET INDEX

SHEET DESCRIPTION

M-MH-01 LEGENDS, NOTES, AND SYMBOLS

M-MD-01 PARTIAL THIRD FLOOR PLAN - PART A - DUCT DEMO

M-MD-02 PARTIAL THIRD FLOOR PLAN - PART B - DUCT DEMO

M-MD-03 PARTIAL THIRD FLOOR PLAN - PART C - DUCT DEMO

M-MD-04 PARTIAL THIRD FLOOR PLAN - PART A - PIPE DEMO

M-MD-05 PARTIAL THIRD FLOOR PLAN - PART B - PIPE DEMO

M-MD-06 PARTIAL THIRD FLOOR PLAN - PART C - PIPE DEMO

M-MH-13 PARTIAL ATTIC PLAN - PART B - DUCT DEMO

M-MH-14 PARTIAL ATTIC PLAN - PART C - DUCT DEMO

M-MH-02 PARTIAL THIRD FLOOR PLAN - PART A - DUCT NEW WORK

M-MH-03 PARTIAL THIRD FLOOR PLAN - PART B - DUCT NEW WORK

M-MH-04 PARTIAL THIRD FLOOR PLAN - PART C - DUCT NEW WORK

M-MH-05 PARTIAL ATTIC PLAN - PART B - DUCT NEW WORK

M-MH-06 PARTIAL ATTIC PLAN - PART C - DUCT NEW WORK

M-MP-01 PARTIAL THIRD FLOOR PLAN - PART A - PIPE NEW WORK

M-MP-02 PARTIAL THIRD FLOOR PLAN - PART B - PIPE NEW WORK

M-MP-03 PARTIAL THIRD FLOOR PLAN - PART C - PIPE NEW WORK

M-MH-07 SCHEDULES

M-MH-08 SCHEDULES

M-MH-09 MECHANICAL DETAILS

M-MH-10 MECHANICAL DETAILS

M-MH-11 MECHANICAL DETAILS

M-MH-12 MECHANICAL DETAILS

M-MI-01 MECHANICAL CONTROLS

M-MI-02 MECHANICAL CONTROLS

No. Date Description

X3 X3

X4

X9

X10

X11

X12

X13

X14

XI XJ

XK

XL XM XN XO

XP

XQ XR XS

X6.1

X7.1

X12.1

X12.2 X12.3

X8

X5

X6

X7 M

A T

C H

L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

B

M A

T C

H L

IN

E

P A

R T

B

M A

T C

H L

IN

E

P A

R T

C

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

C

M A

T C

H L

IN

E

P A

R T

A

T

T

A 220

A 125

A 120

A 285

A 55

B 75

A 125A 125

A 125 A 125

B 400

A 100

A 100

A 100

A 100

A 155

B 195

A 55

A 145

A 115

A 370

B 370

A 155

A 205

A 155

A 350

A 350

B 405

A 275

B 400

A 220

A 190

A 235

B 500

190235

B 140

DEMOLITION NOTES:

1. REMOVE EXISTING UNDER WINDOW WALL MOUNTED HEATERS AND STEAM PIPING AND CAP OFF EXISTING PIPING DOWN AT THE SLAB OR AS LOW AS POSSIBLE. STEAM PIPING HAS ASBESTOS SO ALLOW

FOR ASBESTOS REMOVAL ON STEAM PIPING ROUTED TO WALL MOUNTED HEATERS. WALLS TO BE

PATCHED TO MATCH EXISTING, REFER TO ARCHITECTURAL FOR OTHER REQUIREMENTS REGUARDING

WALL PATCHING.

2. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. EXISTING EQUIPMENT, STRUCTURE, DUCTWORK, ETC. LOCATED ON DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA. CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT

AND ENGINEER PRIOR TO BEGINNING DEMOLITION. START UP OF DEMOLITION SHALL SIGNIFY

CONTRACTORS ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL

REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT.

3. CONTRACTOR SHALL PERFORM A PRE-BID SURVEY TO FIELD-VERIFY AND COORDINATE ALL DIMENSIONS PROIR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, ELECTRUCAL CONDUIT, AND PNEUMATIC TUBING. THE COST OF REROUTING DUCTWORK OR PIPING DUE

TO CONFLICTS WITH EXISTING CONDITIONS SHALL BE PAID BY THE CONTRACTOR.

4. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO THE OTHER SPACES. ALL MECHANICAL SYSTEMS THAT RUN INTO THE SPACE BUT DO NOT SERVE ANYTHING SHALL BE REMOVED BACK TO WHERE THEY ENTER THE SPACE TO FREE-UP VALUABLE CLREANCE FOR

NEW DUCT AND PIPING.

5. CONTRACTOR SHALL PROVIDE MECHANICAL WORK FOR PHASING AS REQUIRED OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECTURAL PHASING PLAN, TEMPORARY MECHANICAL SERVICES SHALL BE

PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDED TO REMAIN ACTIVE.

6. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF.

7. CONTRACTOR SHALL REMOVE EXISTING THERMOSTATS IN RENOVATION SPACE. REMOVED

THERMOSTATS SHALL BE DISPOSED OF.

8. PROPERLY REMOVE AND DISPOSE OF ALL INDICATED EXISTING TO BE REMOVED HVAC DUCTWORK AND

AIR DISTRIBUTION DEVICES.

9. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, THERMOSTATS, CONDUIT, ETC… TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY

EXISTING OPENINGS IN RATED WALLS OR FLOORS.

10. PROVIDE TEMPORARY NEGATIVE AIR MACHINES FOR CONSTRUCTION AREA. MAINTAIN A NEGATIVE PRESSURE IN THE AREA RELATIVE TO THE ADJACENT SPACES AT A MINIMUM OF -0.03” W.C. PROVIDE SHEET ROCK TYPE WALL BARRIER PARTITIONS WITH AIR TIGHT OR LOW LEAKAGE CONSTRUCTION ACCESS. FAN TO BE EQUIVALENT TO HEPA-AIRE PAS1200HC, 800 CFM, ¼ HP, 120 VOLT. PROVIDE AS MANY MACHINES AS NECESSARY TO MAINTAIN NEGATIVE PRESSURE REQUIREMENT IN RENOVATION SPACE.

REFERENCE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION CONCERNING ICRA.

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:4

A

M

06-13-2023

626A4-19-101

M-MD-01

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART A -

DUCT DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

0 2' 4' 8'1'

1 PARTIAL WARD 1B FLOOR PLAN - PART A - DUCT DEMO

X1X1

X2 X2

X3 X3

X4

X9

X10

X11

X0 X0

XB XC XD XE XF XG XH XI XJ

XK

X6.1

X7.1

X12.2 X12.3

X8

XA

X5

X6

X7

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

B

A 210

B 420

B 530

A 265A 265

A 135

A 265 A 265

B 525

A 155 A 155

A 155

A 165

A 229

A 210

A 60 B 425

A 60

B 75

A 185

A 185

A 50

B 65

A 240

A 65

A 260

A 70

B 90

A 60

B 195

A 215

A 220 A 125

A 120

B 140 285

A 285

A 55

B 75

A 220

A 235

A 190

190235B 440

A 385

B 155

B 160

A 225

B 90

A 55

A 195 A 135

A 195

A 175

A 220

A 110

B 440

A 110

A 110

A 110

B 355

A 185

A 185 B 180

A 150

A 230

A 230

B 445

A 195

A 250

A 195

REMOVE VERTICAL PORTION OF

EXHAUST DUCTWORK THRU THIS FLOOR

AND OFFSET TO NEW CHASE SHOWN ON

PART B NEW WORK SHEET, FIELD VERIFY

EXACT LOCATION AND SIZE

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:5

A

M

06-13-2023

626A4-19-101

M-MD-02

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART B -

DUCT DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

0 2' 4' 8'1'

1 PARTIAL WARD 1B FLOOR PLAN - PART B - DUCT DEMO

DEMOLITION NOTES:

1. REMOVE EXISTING UNDER WINDOW WALL MOUNTED HEATERS AND PIPING AND CAP OFF EXISTING PIPING DOWN AT FLOOR SLAB OR AS LOW AS POSSIBLE. STEAM PIPING HAS ASBESTOS SO ALLOW FOR ASBESTOS REMOVAL ON STEAM PIPING ROUTED TO WALL MOUNTED HEATERS. WALLS TO BE PATCHED TO MATCH EXISTING, REFER TO

ARCHITECTURAL FOR OTHER REQUIREMENTS REGUARDING WALL PATCHING.

2. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. EXISTING EQUIPMENT, STRUCTURE, DUCTWORK, ETC.

LOCATED ON DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA.

CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT AND ENGINEER PRIOR TO BEGINNING DEMOLITION. START UP OF DEMOLITION SHALL SIGNIFY CONTRACTORS ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED DEMOLITION WHETHER SHOWN

ON THE PLANS OR NOT.

3. CONTRACTOR SHALL PERFORM A PRE-BID SURVEY TO FIELD-VERIFY AND COORDINATE ALL DIMENSIONS PROIR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, ELECTRUCAL CONDUIT, AND PNEUMATIC TUBING. THE COST OF REROUTING DUCTWORK OR PIPING DUE TO CONFLICTS WITH EXISTING

CONDITIONS SHALL BE PAID BY THE CONTRACTOR.

4. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO THE OTHER SPACES.

ALL MECHANICAL SYSTEMS THAT RUN INTO THE SPACE BUT DO NOT SERVE ANYTHING SHALL BE REMOVED BACK TO WHERE THEY ENTER THE SPACE TO FREE-UP VALUABLE CLREANCE FOR NEW DUCT AND PIPING.

5. CONTRACTOR SHALL PROVIDE MECHANICAL WORK FOR PHASING AS REQUIRED OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECTURAL PHASING PLAN, TEMPORARY MECHANICAL SERVICES SHALL BE

PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDED TO REMAIN ACTIVE.

6. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF.

7. CONTRACTOR SHALL REMOVE EXISTING THERMOSTATS IN RENOVATION SPACE. REMOVED THERMOSTATS SHALL

BE DISPOSED OF.

8. PROPERLY REMOVE AND DISPOSE OF ALL INDICATED EXISTING TO BE REMOVED HVAC DUCTWORK AND AIR

DISTRIBUTION DEVICES.

9. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, THERMOSTATS, CONDUIT, ETC… TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY EXISTING OPENINGS

IN RATED WALLS OR FLOORS.

10. PROVIDE TEMPORARY NEGATIVE AIR MACHINES FOR CONSTRUCTION AREA. MAINTAIN A NEGATIVE PRESSURE IN THE AREA RELATIVE TO THE ADJACENT SPACES AT A MINIMUM OF -0.03” W.C. PROVIDE SHEET ROCK TYPE WALL BARRIER PARTITIONS WITH AIR TIGHT OR LOW LEAKAGE CONSTRUCTION ACCESS. FAN TO BE EQUIVALENT TO HEPA-AIRE PAS1200HC, 800 CFM, ¼ HP, 120 VOLT. PROVIDE AS MANY MACHINES AS NECESSARY TO MAINTAIN NEGATIVE PRESSURE REQUIREMENT IN RENOVATION SPACE. REFERENCE ARCHITECTURAL PLANS FOR

ADDITIONAL INFORMATION CONCERNING ICRA.

X3 X3

X4

X9

X10

X11

X0 X0

XQ XR XS XT XU XV XW XX XY

X6.1

X7.1

X12.2

XZ

X8

X5

X6

X7

M A

T C

H L

IN

E

P A

R T

C

M A

T C

H L

IN

E

P A

R T

A

DEMOLITION NOTES:

1. REMOVE EXISTING UNDER WINDOW WALL MOUNTED HEATERS AND PIPING AND CAP OFF EXISTING PIPING DOWN AT THE FLOOR SLAB OR AS LOW AS POSSIBLE. STEAM PIPING HAS ASBESTOS SO ALLOW FOR ASBESTOS REMOVAL ON STEAM PIPING ROUTED TO WALL MOUNTED HEATERS. WALLS TO BE PATCHED TO MATCH EXISTING, REFER TO ARCHITECTURAL FOR OTHER REQUIREMENTS REGUARDING WALL PATCHING.

2. THE DEMOLITION PLAN IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. EXISTING EQUIPMENT, STRUCTURE, DUCTWORK, ETC.

LOCATED ON DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA.

CONTRACTOR SHALL VERIFY SERVICES AND LOCATIONS PRIOR TO ANY DEMOLITION WORK. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT AND ENGINEER PRIOR TO BEGINNING DEMOLITION. START UP OF DEMOLITION SHALL SIGNIFY CONTRACTORS ACCEPTANCE OF EXISTING CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED DEMOLITION WHETHER SHOWN

ON THE PLANS OR NOT.

3. CONTRACTOR SHALL PERFORM A PRE-BID SURVEY TO FIELD-VERIFY AND COORDINATE ALL DIMENSIONS PROIR TO PROCUREMENT OR FABRICATION. FIELD CONDITIONS SHALL GOVERN. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, ELECTRUCAL CONDUIT, AND PNEUMATIC TUBING. THE COST OF REROUTING DUCTWORK OR PIPING DUE TO CONFLICTS WITH EXISTING

CONDITIONS SHALL BE PAID BY THE CONTRACTOR.

4. ALL MECHANICAL SYSTEMS SERVING OTHER SPACES OR FLOORS THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE ANY DISRUPTION TO THE OTHER SPACES.

ALL MECHANICAL SYSTEMS THAT RUN INTO THE SPACE BUT DO NOT SERVE ANYTHING SHALL BE REMOVED BACK TO WHERE THEY ENTER THE SPACE TO FREE-UP VALUABLE CLREANCE FOR NEW DUCT AND PIPING.

5. CONTRACTOR SHALL PROVIDE MECHANICAL WORK FOR PHASING AS REQUIRED OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECTURAL PHASING PLAN, TEMPORARY MECHANICAL SERVICES SHALL BE

PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDED TO REMAIN ACTIVE.

6. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OF.

7. CONTRACTOR SHALL REMOVE EXISTING THERMOSTATS IN RENOVATION SPACE. REMOVED THERMOSTATS

SHALL BE DISPOSED OF.

8. PROPERLY REMOVE AND DISPOSE OF ALL INDICATED EXISTING TO BE REMOVED HVAC DUCTWORK AND AIR

DISTRIBUTION DEVICES.

9. PATCH HOLES LEFT IN WALLS AND FLOORS AFTER REMOVAL OF EXISTING DUCTWORK, THERMOSTATS, CONDUIT, ETC… TO MATCH NEW OR EXISTING CONSTRUCTION AND FIRE RATING. THIS INCLUDES ANY EXISTING

OPENINGS IN RATED WALLS OR FLOORS.

10. PROVIDE TEMPORARY NEGATIVE AIR MACHINES FOR CONSTRUCTION AREA. MAINTAIN A NEGATIVE PRESSURE IN THE AREA RELATIVE TO THE ADJACENT SPACES AT A MINIMUM OF -0.03” W.C. PROVIDE SHEET ROCK TYPE WALL BARRIER PARTITIONS WITH AIR TIGHT OR LOW LEAKAGE CONSTRUCTION ACCESS. FAN TO BE EQUIVALENT TO HEPA-AIRE PAS1200HC, 800 CFM, ¼ HP, 120 VOLT. PROVIDE AS MANY MACHINES AS NECESSARY TO MAINTAIN NEGATIVE PRESSURE REQUIREMENT IN RENOVATION SPACE. REFERENCE ARCHITECTURAL PLANS FOR

ADDITIONAL INFORMATION CONCERNING ICRA.

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:0

A

M

06-13-2023

626A4-19-101

M-MD-03

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART C -

DUCT DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

1 PARTIAL WARD 1B FLOOR PLAN - PART C - DUCT DEMO

0 2' 4' 8'1'

X3 X3

X4

X9

X10

X11

X12

X13

X14

XI XJ

XK

XL XM XN XO

XP

XQ XR XS

X6.1

X7.1

X12.1

X12.2 X12.3

X8

X5

X6

X7

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

B

M A

T C

H L

IN

E

P A

R T

B

M A

T C

H L

IN

E

P A

R T

C

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

C

M A

T C

H L

IN

E

P A

R T

A

T T

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

REMOVE ALL INDOOR REFRIGERANT

PIPING ASSOCATED WITH RETHERM

UNITS. SEE NEW FLOOR PLAN FOR

NEW LOCATION OF RETHERM UNIT

REMOVE ALL HOT WATER SUPPLY AND RETURN BACK TO

CHASE, REMOVE ALL REHEAT BOXES, REMOVE ALL

THERMOSTATS. (TYPICAL FOR PART A, B, & C.)

THIS PORTION OF HOT WATER PIPING NEEDS TO

REMAIN IN PLACE TO SERVE THE 4TH FLOOR REHEAT

BOXES UNTIL CONTRACTOR IS READY TO INSTALL

NEW PIPING TO MINIMIZE THE TIME THAT THE

4TH FLOOR WILL BE WITHOUT HEATING.

EXISTING 1-1/4" HOT WATER

SUPPLY AND RETURN UP

TO 4TH FLOOR REHEAT BOXES

SEE PART B FOR CONTINUATION

SEE PART C FOR CONTINUATION

THERE IS APPARENTLY SOME CHILLED WATER

SUPPLY & RETURN UP INTO THE 4TH FLOOR ATTIC

SERVING AN EXISTING AHU. PIPING MAY BE

ROUTED UP ON EITHER SIDE OF CORRIDOR AND

NEEDS TO REMAIN. SEE PICTURE # 1 THIS SHEET

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:0

A

M

06-13-2023

626A4-19-101

M-MD-04

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART A -

PIPE DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

0 2' 4' 8'1'

1 PARTIAL WARD 1B FLOOR PLAN - PART A - PIPE DEMO

PICTURE # 1

X3 X3

X4

X9

X10

X11

X0 X0

XB XC XD XE XF XG XH XI XJ

XK

X6.1

X7.1

X12.2 X12.3

X8

XA

X5

X6

X7

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

B

T

T T

T

T

T T

T T

T

T

T

T

T

T

T

T

T

T T

T

T

T

T

T

EXISTING 2" CHILLED WATER

SUPPLY AND RETURN PIPING

UP TO EXISTING AHU IN ATTIC,

FIELD VERIFY EXACT LOCATION

EXISTING 1-1/4" HOT WATER

SUPPLY AND RETURN UP

TO 4TH FLOOR REHEAT BOXES

THIS PORTION OF HOT WATER PIPING NEEDS TO

REMAIN IN PLACE TO SERVE THE 4TH FLOOR REHEAT

BOXES UNTIL CONTRACTOR IS READY TO INSTALL

NEW PIPING TO MINIMIZE THE TIME THAT THE

4TH FLOOR WILL BE WITHOUT HEATING.

SEE PART A FOR

CONTINUATION

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:1

A

M

06-13-2023

626A4-19-101

M-MD-05

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART B -

PIPE DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

0 2' 4' 8'1'

1 PARTIAL WARD 1B FLOOR PLAN - PART B - PIPE DEMO

X3 X3

X4

X9

X10

X11

X0 X0

XQ XR XS XT XU XV XW XX XY

X6.1

X7.1

X12.2

XZ

X8

X5

X6

X7

M A

T C

H L

IN

E

P A

R T

C

M A

T C

H L

IN

E

P A

R T

A

T T

T

T T

T

T

T

T

T

T

T

T

T T

T

T

T

T T

TSEE PART A FOR

CONTINUATION

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:1

A

M

06-13-2023

626A4-19-101

M-MD-06

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART C -

PIPE DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

0 2' 4' 8'1'

1 PARTIAL WARD 1B FLOOR PLAN - PART C - PIPE DEMO

X3 X3

X4

X9

X10

X11

X0 X0

XB XC XD XE XF XG XH XIXJ

XK

X6.1

X7.1

X12.2 X12.3

X8

XA

X5 X5

X6

X7

EXISTING AHU-1 IN ATTIC

EXISTING RETURN FAN

EXISTING EXHAUST FAN

EXISTING EXHAUST FANS

SERVING WARD 1A

ISOLATION ROOM

EXISTING EXHAUST FAN

REMOVE EXISTING

EXHAUST FAN AND

DUCTWORK, SEE

PICTURE # 2 THIS SHEET

REMOVE EXISTING

FILTER

REMOVE EXISTING

DUCTWORK AND CAP

OPENING, SEE PICTURE

# 1 THIS SHEET

EXISTING ELECTRICAL

EXISTING SMALL DUCT

DOWN THRU FLOOR. IT

IS NOT KNOWN WHERE

THIS DUCT IS ROUTED

BELOW, IT WILL NEED

TO BE OFF-SET IN THE

CEILING BELOW. SEE

PICTURE # 5 THIS

SHEET.

EXISTING COPPER VENT

LINES DOWN THRU

FLOOR, SEE PICTURE#4

ON THIS SHEET.

REMOVE EXISTING AIR

VALVE AND DUCTWORK

ELECTRICAL

EXISTING RETURN DUCT

EXISTING BIO-HAZARD

DUCT DOWN THRU

FLOOR

PICTURE # 1

PICTURE # 2

PICTURE # 3

REMOVE EXHAUST DUCTWORK,

SEE PICTURE # 3 THIS SHEET

PICTURE # 4PICTURE # 5

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:4

A

M

06-13-2023

626A4-19-101

M-MH-13

AE RENOVATE WARD 1B

PARTIAL ATTIC PLAN - PART B - DUCT

DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

1 FOURTH FLOOR - PART B - DUCT DEMO

RQI

(OFOI)

RQI

(OFOI)

RQI

(OFOI)

X1

X2

X3

X4

X9

X0

XQ XR XS XT XU XV XW XX XY

X6.1

X7.1

XZ

X8

X5

X6

X7

EXHSTING AHU-2 IN ATTIC

REMOVE EXISTING

EXHAUST FAN AND

ASSOCIATED DUCTWORK.

SEE PICTURE # 3 ON THIS

SHEET.

EXHSTING RETURN FAN IN ATTIC

EXHSTING EXHAUST FAN

EXHAUST FANS SERVING WARD 1A

ISOLATION ROOM

REMOVE EXISTING EXHAUST FAN AND

ASSOCIATED DUCTWORK,

SEE PICTURE # 2 THIS SHEET

EXHAUST FILTER SERVING WARD

1A ISOLATION ROOM

PATCH EXISTING OPENING

REMOVE EXISTING EXHAUST FILTER

AND ASSOCIATED DUCTWORK,

SEE PICTURE # 1 THIS SHEET.

EXISTING OPENING THRU FLOOR

TO BE PATCHED

REMOVE EXISTING

EXHAUST DUCT AND

BLANK-OFF LOUVER

DO NOT PASS THRU ANU PORTION

OF AHU UNLESS IT IS UPSTREAM

OF FILTER SECTION

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:4

A

M

06-13-2023

626A4-19-101

M-MH-14

AE RENOVATE WARD 1B

PARTIAL ATTIC PLAN - PART C - DUCT

DEMO

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

1 FOURTH FLOOR - PART C - DUCT DEMO

0 2' 4' 8'1'

PICTURE # 1

PICTURE # 2

PICTURE # 3

FEC

F E

C

CR CR

CR

C R

X3 X3

X4 X4

X9 X9X11

X12

X13

X14

XI XJ

XK

XL XM XN XO

XP

XQ XR XS

X6.1 X6.1

X7.1 X7.1

X12.1

X12.2

X12.3

X8 X8

X5 X5

X6 X6

X7 X7

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

B

M A

T C

H L

IN

E

P A

R T

B

PANTRY

B338A

SERVING KITCHEN

B338

DINING/DAY ROOM

B337

RETHERM

B361

LAUNDRY

B359 CLEAN SUPPLY

B363

CHUTE

B360

NURSE STATION

B336

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

C

EQUIP STORAGE

B301

INPATIENT REHAB

B303

STAFF LOUNGE

B304

STAFF LOCKERS

B304B

CHAIR ALCOVE

B305

FAM. LOUNGE

B307

CONSULT

B310

FAM/PUB. TLT.

B308

REC.THR. STOR.

B309

TEAM ROOM

B332

DATA

B335

PAT. TLT.

B331A

PRIVATE ROOM

B331

CHARGE NURSE

B336A

SOCIAL WORKER

B302

DIRTY

B362

NURSE MANAGER

B333

MEDS

B336B

COMM

B334

STAFF TLT.

B304A

CORRIDOR

B300

CORRIDOR

B370

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

C

CHASE

VENDING

B300A

EXISTING RISER

B370A

ELEV.

ELEV.

CHASE

FD

FD

STAIR 1

(NOT IN CONTRACT)

(N.I.C)

(N.I.C)

0"

+1 3/4"+1 3/4"

+1 3/4"+1 3/4"

0"

+2"

+2 1/4"

+1 5/8"

+1 5/8"

B301A

STAIR 1

B306

A 220

A 220

A 200

A 215

A 310

A 230

A 225

A 30

A 225

A 230

A 280

A 280

A 225

A 230

A 230 A 230

A 230

A 350

A 250

A 100

A 60

A 150

A 240

A 250

A 250

A 40

A 300

A 150

A 260 V1-19

B 350

B 600

V1-20

B 460 A 460

B 100 A 70 B 50

V1-21

B 455 x1

V1-22

B 510

V2-25

V1-23

B 75

V1-24

B 150

B 375

B 75

B 240

V1-26

V1-28

V1-27

B 465

V2-24

B 440

V2-23

B 300

B 230

V2-21 V2-20

B 310

B 350

A 200

V2-19

V2-18B 75 x1 x1 ø ø

14ø

16x12

24x1428x14

28x1432x14 x1

16x12 x1

2 16 x1 x1

30x12 x1 x1

30x14

30x14

25/12 28/12

24x1030x1236x12 x1

8x8

10x10 UP TO EF-1

ON ROOF

4" ALUMINUM DRYER VENT OUT

THRU WALL WITH WEATHER CAP

AND BACKDRAFT DAMPER

V1-25

B 200 x1

10ø 6x

12x8 8ø

6ø 6ø

STRUCTURAL CEILING STEPS DOWN SOME BETWEEN

COLUMN LINE "XJ" AND COLUMN LINE "XQ".

CONTRACTOR TO OFFSET DUCTS AND PIPING TO

ACCOMMODATE STEP DOWN.

DDC

PANEL

12x10

B 50

18x18 x1

V2-22

AC-1 AC-2

CU-2

CU-1

18/12

EXISTING EXHAUST DUCT

FROM BELOW UP TO

ATTIC

12x10

24x14

B 825 16x12 x1

8x10

/1

18/12 ø

6x6 x1

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:2

A

M

06-13-2023

626A4-19-101

M-MH-02

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART A -

DUCT NEW WORK

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

1 PARTIAL WARD 1B FLOOR PLAN - PART A - DUCT NEW WORK

F E

C

F E

C

FEC FEC

FEC

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

B

PRIVATE ROOM

B349

PRIVATE ROOM

B348

ISO ROOM

B347

CLEAN UTILITY

B346

ELEC.

B344

EQUIP STOR.

B343

CLEAN LINEN

B351

SOILED HOLD

B352

BARI PRIVATE

ROOM

B355

BARI. TLT.

B355A

NOURISHMENT

B356

SUB NS.

B358

HAC

B357

STAFF TLT.

B358A

PANTRY

B338A

SERVING

KITCHEN

B338

DINING/DAY

ROOM

B337

RETHERM

B361

LAUNDRY

B359

CLEAN SUPPLY

B363

CHUTE

B360

X1X1

X2 X2

X3 X3

X4

X9

X10 X10

X11

X0 X0

XB XC XD XE XF XG XH XI XJ

XK

X6.1

X7.1

X12.2

X12.3

X8

XA

X5

X6

X7

CORRIDOR

B374

CORRIDOR

B375

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

B

TEAM WORK

B341

DIRTY

B362

ANTE

B347A

PRIVATE ROOM

B354

PRIVATE ROOM

B353

PAT. TLT.

B354A

PAT. TLT.

B353A

CHASE

PRIVATE ROOM

B339

PRIVATE ROOM

B340

FD

TYP

D N

FD

FD

FD FD

FD

FD

FD

FD

FD

FDPRIVATE ROOM

B350

PAT. TLT.

B349A

PAT. TLT.

B340A PAT. TLT.

B339A

PAT. TLT.

B350A

PAT. TLT.

B348A

PAT. TLT.

B347B

CORRIDOR

B376

STAIR 2

CHASE

B338B

(NOT IN CONTRACT)

FD

SHOWER TYPE 1

SHOWER TYPE 2

SHOWER TYPE 2

SHOWER TYPE 1

SHOWER TYPE 3

SHOWER TYPE 4

SHOWER TYPE 5

SHOWER TYPE 1

SHOWER TYPE 2

FD

B342

STAIR 2

B345

FD

FD

FD

FD

FD FD

FD

A 340

A 260 A 260

A 40

A 30

A 205

A 205

A 190

A 185

A 90

A 70A 100

A 235 A 235

A 230

A 260 A 260

A 30

A 40

A 200

A 200

A 310

A 40

A 150

A 275

A 250

A 250

A 40

A 275 A 30

A 240

A 265

A 275 A 30

A 40

A 170 A 275

A 175

A 110

A 275 A 100

A 75

A 235

GENERAL NOTES:

1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A FURRED CHASE OR ABOVE

HARD SUSPENDED CEILING, OR ACOUSTICAL CEILING.

2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. DUCT SIZES ARE NET

INSIDE DIMENSIONS.

3. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE FURNISHED AND INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS. COORDINATE LOCATION WITH MECHANICAL INSTALLATION AND

DEMONSTRATE ACCESS TO EQUIPMENT SERVED.

4. FOR TYPICAL WATER PIPING CONNECTIONS TO EQUIPMENT, SEE STANDARD EQUIPMENT DETAILS.

5. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE CFM's, REFER TO AIR DISTRIBUTION

DEVICE SCHEDULE FOR ADDITIONAL INFORMATION .

6. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE TO PROVIDE COUNTER FLOW

BETWEEN WATER AND AIR.

7. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING DIFFUSERS, REGISTERS, AND GRILLES.

A 225

A 280

A 460

B 340

V1-13

B 420

B 110

B 360

B 80 B 110

B 305

V1-10

V1-9

B 140

B 730

B 150

B 730

B 230

B 240

B 730

B 350

V1-18

V1-17 V1-15

V1-16

C 330

D 330

V1-2

B 160

AV1-1

B 125

B 600

B 110

B 80

B 190 V1-5

B 215

V1-6

B 80

B 110

B 275

V1-7

V1-4

B 150

B 80

B 110

A 230

B 455

V1-19

V1-20

B 460

B 100

A 70

B 50

B 600

V1-21

B 510

V1-22 x1

10x10

V1-14

20x12

15/12 ø

20/12 16x14 32x14 x1

24x1424x1014x8

16x10 x1

30x14 20x12 x8

12x12

18x16

36x16

/1 x1 x1

42x14

22/14

/1 ø x1 x1 x1

10ø x1

12x12

8x

6x x8

8x

10x10 x1

18x10

10x10

10x10 x8

12x8 x1

12x8 x1 x1

16x12 x1 x1

28x14

24x14

30x1236x12 24x10 x1 x1

12x10 x1

EV1-1

EV1-2

EXHAUST DUCTS FROM WARD

1A UP TO ATTIC

12x1210ø x1

12x10

8x8

V1-8

V1-1

V1-11 V1-12

V1-3

EXISTING EXHAUST DUCT DOWN FROM ATTIC

SPACE. REROUTE ABOVE CEILING AND ROUTE

DOWN IN NEW CHASE TO FLOOR BELOW.

REROUTE IN CEILING OF FLOOR BELOW TO

CONNECT BACK TO EXISTING DUCT. SIZE IS

ABOUT 18X18, FIELD VERIFY.

PROVIDE FD AT SLAB

STRUCTURAL CEILING STEPS DOWN ABOUT

1.5 FEET JUST LEFT OF COLUMN LINE "XB"

AND CONTINUES OVER TO COLUMN LINE "XA".

CONTRACTOR TO OFFSET DUCTS AND PIPING

TO ACCOMODATE

OFF-SET EXISTING EXHAUST DUCT

FROM ATTIC SPACE DOWN TO

FLOOR BELOW

12x10

B 50

CONTRACTOR TO ENSURE NO PART OF THE

FACE OF DIFFUSER INTERFEARS WITH THE

HOIST AND TRACK SYSTEM MOVEMENT.

(TYPICAL FOR DIFFUSERS MOUNTED ABOVE

TRACK AND HOIST SYSTEM)

12x6 12x10 x1

8x6

24x14 28x14

10ø

10ø

12x8

10x8

COORDINATE DIFFUSER AND GRILLE

LOCATIONS WITH BARIATRIC LIFT

VENDOR INSTALLATION PRIOR TO

ROUTING DUCT RUNOUTS SERVING

THESE.

12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554

©Copyright 2023

TLC No.:

www.tlc-engineers.com

119437

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

PROJECT TEAM:

Office of

Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Department of Veterans Affairs

KEYPLAN

MURFREESBORO, TN

615.370.8500

615.370.8530 hfrdesign.com

214 Centerview Drive Suite 300 Brentwood, TN 37027

BLDG 2

BLDG 1

BLDG 9

Phase

FULLY SPRINKLERED

C R e v it

L o c a ls

\1

-A lv in

C .Y o rk

V A

M C

R e n o v a te W a rd

B

M E

C H

R jim .e ld e r@ tl c -e n g

.c o m .r v t

/1

/2

:2

:4

A

M

06-13-2023

626A4-19-101

M-MH-03

AE RENOVATE WARD 1B

PARTIAL THIRD FLOOR PLAN - PART B -

DUCT NEW WORK

JE

HFR Project No: 2019056

100% CONSTRUCTION

DOCUMENTS

1 PARTIAL WARD 1B FLOOR PLAN - PART B - DUCT NEW WORK

FEC FEC

F E

C

F E

C

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

A

M A

T C

H L

IN

E

P A

R T

C

M A

T C

H L

IN

E

P A

R T

C

TEAM ROOM

B332

REC.THR. STOR.

B309

CONSULT

B310

FAM/PUB. TLT.

B308

PRIVATE ROOM

B331

PAT. TLT.

B331A

PAT. TLT.

B330A

PRIVATE ROOM

B330

TEAM WORK

ROOM

B329

WOUND CART

STOR.

B311B

ST. TLT.

B311A

CLEAN LINEN

B318

BARI PRIVATE

ROOM

B313

BARIATRIC

PATIENT TOILET

B313A

NOURISH

B312

CLEAN UTILITY

B320

ELEC.

B326

SOILED HOLD

B327

HAC.

B325

ISO ROOM

B321

PAT. TLT.

B322A

SUB N.S.

B311

X1X1

X2 X2

X3 X3

X4

X9

X10

X0 X0

XQ XR XS XT XU XV XW XX XY XZ

X8

X5

X6

X7

NURSE

MANAGER

B333

PAT. TLT.

B321B

PRIVATE ROOM

B322

EMPTY CYL.

STOR.

B317

FULL CYL. STOR.

B316

PAT. TLT.

B315A PAT. TLT.

B314A

ANTE

B321A

CORRIDOR

B371

CORRIDOR

B372

CORRIDOR

B373

PRIVATE ROOM

B314

PRIVATE ROOM

B315

FD

FD

FD

FD

FD

PRIVATE ROOM

B324

PRIVATE ROOM

B323

PAT. TLT.

B323A

PAT. TLT.

B324A

STAIR 3

FD

FD

FD

FD

(NOT IN CONTRACT)

FD

SHOWER TYPE 1

SHOWER TYPE 2

SHOWER TYPE 2

SHOWER TYPE 1

SHOWER TYPE 1

SHOWER TYPE 2

SHOWER TYPE 3

SHOWER TYPE 4

SHOWER TYPE 5

FD

STAIR 3

B319

CHASE

B328

FD

FD

FD

FD

FD

A 230

A 60

A 50

A 150

A 50

A 200

A 245

A 260

A 40

A

A 280

A 30

A 205

A 180

A 30

A 205

A 40

A 200

A 320

A 40

A 30

A 205

A 240

A 90

A 400

A 215A 215

A 215

A 215A 215

A 200

A 105

A 310A 200

A 30

A 40

A 310

A 245

A 205A 200

A 180

A 255

A 200

A 30

V2-19

V2-18 B 825

V2-17

B 240

B 110

B 80B 350

B 310

V2-20 V2-21

V2-9

V2-16

B 595

V2-8

B 230

B 110

C 50

V2-2

B 170

V2-1

AV2-1

EV2-2

EV2-1

B 125

B 110

B 600

V2-4

V2-5

B 230

B 310

V2-6

V2-7

B 110

B 80

B 80

B 330

B 50B 50

V2-11

V2-12

B 250

B 110 B 80

B 360 B 435

B 140

B 400

V2-14

V2-15 V2-13B 400 x1

23/12 20/12 15/12 x1

24x10 x1

14x1024x10

32x10

B 100

/1

20/12

/1

/1 x8 x8

8x x1 x1 x1

10ø

10x12 x1 x1

10x10

10x10 x1 x1

10x10

8x ø

14x…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .