This document is a solicitation for a federal contract opportunity for the construction of a Guam Defense Radar System Command Center and associated infrastructure. The project includes the construction of a command center, power generation facility, switchgear building, fuel storage facility, entry control facility, and related equipment. The contract is anticipated to be in the range of $250,000,000 to $500,000,000, with a performance period of 1,323 calendar days. The solicitation will be issued as a best-value, trade-off source selection, with technical factors including experience, small business utilization, safety, management plan, and past performance being approximately equal to price. Relevant construction experience includes new construction of administrative, office, or communications facilities, secure spaces, and essential facilities in moderate to high seismic areas. A pre-proposal site visit is scheduled for December 11, 2024, and the Request for Proposal will be available on October 30, 2024 through the System for Award Management (SAM) website.

View the file

Other files

File Type Posted
25-1301 CmdCtrl Notice14.pdf PDF
Am-0011 Attachments 25-44.pdf PDF
Am-0011 Attachment 1_Revised Drawings dtd 1-28-2025.pdf PDF
Am-0011.pdf PDF
Am-0011 Attachments 2-24.pdf PDF
25-1301 CmdCtrl Notice13.pdf PDF
25-1301 CmdCtrl Notice12.pdf PDF
25-1301 CmdCtrl Notice11.pdf PDF
Am-0010 Attachment 2_Revised Drawings_Signed.pdf PDF
Am-0010.pdf PDF
25-1301 CmdCtrl Notice10.pdf PDF
25-1301 CmdCtrl Notice9.pdf PDF
Attachment 1_Revised Drawings_dtd 13 and 20 Dec 2024.pdf PDF
Am-0009.pdf PDF
Am-0008.pdf PDF
25-1301 CmdCtrl Notice8.pdf PDF
P693_Sign-in Sheets_Redacted.pdf PDF
Am-0007.pdf PDF
Am-0007 Attachment 1_Revised Drawings dtd 13 Dec 2024.pdf PDF
Am-0006 Attachment 1_Revised Drawings dtd 6 Dec 2024.pdf PDF
Am-0006.pdf PDF
25-1301 CmdCtrl Notice7.pdf PDF
Am-0005 Attachment 1_Revised Drawings dtd 11-22-2024.pdf PDF
Am-0005.pdf PDF
25-1301 CmdCtrl Notice6.pdf PDF
25-1301 CmdCtrl Notice5.pdf PDF
R-P693_Drawings_Final_Vol14.6_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.5_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.8_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.2_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.1_20241007.pdf PDF
25-1301 CmdCtrl Notice4.pdf PDF
R-P693_Drawings_Final_Vol14.7_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.4_20241007.pdf PDF
Am-0004 Attachment 1_Revised Drawings dtd 11-15-2024.pdf PDF
25-1301 CmdCtr Notice3.pdf PDF
Am-0004.pdf PDF
Am-0003.pdf PDF
Am-0003 Attachment 1_Revised Drawings dtd 11-8-2024.pdf PDF
25-1301 CmdCtrl Notice2.pdf PDF
Am-0002.pdf PDF
Am-0001.pdf PDF
25-1301 CmdCtrl Notice1.pdf PDF
P693_Drawings_Final_Vol14.2_20241007-Part3.pdf PDF
P693_Drawings_Final_Vol14.2_20241007-Part2.pdf PDF
P693_Drawings_Final_Vol14.7_20241007.pdf PDF
P693_Drawings_Final_Vol14.3_20241007.pdf PDF
25-1301 P-693 RFP.pdf PDF
P693_Specs_Final_Vol02_20241007.pdf PDF
P693_Drawings_Final_Vol14.6_20241007.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

'-0

20"

3" 3"

3"

3" 3" 3"

1 -1 /2

'-0

20"

M

IN

6" MIN

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

1812861

AWK/DMK

KYM

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

KAHSXMATG

17323378

S

IT

E E

L E

C T

R

IC

A L

U T

IL

IT

Y

D E

T A

IL

S

NTSSCALE: A1

NTSSCALE: C1

TYPICAL EQUIPMENT PAD DETAIL

SCALE: A3

CONCRETE ENCASED ELECTRICAL DUCTBANK (EDB/PDB) - 1X2

DUCTBANK FOR LOW AND/OR MEDIUM VOLTAGE CONDUCTORS - 6" CONDUIT

CONCRETE ENCASED ELECTRICAL DUCTBANK (EDB/PDB) - 2X2

DUCTBANK FOR LOW AND/OR MEDIUM VOLTAGE CONDUCTORS - 6" CONDUIT

ANDREW T. GARDNER

OF TE XASS

TATE

ALNOISSE

F O

R P

ENGIN

E

E R

NSEDECIL

130901

XASA

S

TA

TEXAS REGISTERED ENGINEERING FIRM F-2966

10-04-2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4 via email

10/17/2024

C

B

A

B

B

C

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

KAHTJRATG

17323379

S

IT

E E

L E

C T

R

IC

A L

U T

IL

IT

Y

D E

T A

IL

S

TYPES 5,6,7,8, & 9 (UG-6)

NTSSCALE: A1

A. REFER TO DRAWINGS 14GI-E-001 THROUGH 14GI-E-003

FOR ELECTRICAL LEGENDS, ABBREVIATIONS, AND

GENERAL NOTES.

MANHOLE AND COVERS ARE DESIGNED FOR MAXIMUM

WHEEL LOAD IN ACCORDANCE WITH AASHTO HS20-44.

FOR DETAILS OF CABLE RACKS, DUCT ENTRANCE, AND

PULLING-IN IRONS, SEE DETAIL C3 ON SAME SHEET.

MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL

BE 3000 PSI.

STANDARD ELECTRICAL MANHOLE (TRAFFIC) TYPES 3 & 4 (UG-2)_

NTSSCALE: C1 STANDARD ELECTRICAL MANHOLE (NONTRAFFIC) TYPES 1&2 (UG-1)

NTSSCALE: C3

PULLING-IN IRONS CABLE RACK AND DUCT ENTRANCE (UG-7)

NTSSCALE: A3

STANDARD ELECTRICAL HANDHOLE (NONTRAFFIC) (COMPOSITE-FIBERGLASS)

ANDREW T. GARDNER

OF TE XASS

TATE

ALNOISSE

F O

R P

ENGIN

E

E R

NSEDECIL

130901

XASA

S

TA

TEXAS REGISTERED ENGINEERING FIRM F-2966

10-04-2024

14GI-E-001 14GI-E-003

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

FEEDER 65

CONTINUED

CONTINUED

CONTINUED

FEEDER 65

CONTINUED

FE

ED

ER

FE

ED

ER

FE

ED

ER

FE

ED

ER

FE

ED

ER

26052

MAIN SUBSTATION

FE

ED

ER

FE

ED

ER

SPARE

88919394 89

FE

ED

ER

FE

ED

ER

BUS TIE

CONTINUED

CONTINUED

J J J J

JJJJ

J

J

J

J

J

J JJ

FE

ED

ER

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

KAHSXMATG

17323380

S

IT

E E

L E

C T

R

IC

A L

U T

IL

IT

Y

O N

E -L

IN

E

D

IA

G R

A M

ONE-LINE DIAGRAM - SITE ELECTRICAL UTILITY

NTSSCALE: A1

A. ONE-LINE DIAGRAM IS BASED ON EXISTING RECORDS

AND IS SHOWN FOR REFERENCE ONLY. FIELD VERIFY

EQUIPMENT LOCATIONS AND QUANTITIES PRIOR TO

COMMENCEMENT OF WORK.

DEMOLISH EXISTING ST-7A, ST-8A, ST-14C, FT-7A, FT-8A,

FT-14A, AND ALL ASSOCIATED CONDUITS AND

CONDUCTORS BACK TO ST-6A AND UP TO ST-17C.

DEMOLISH EXISTING ST-13B, FT-13B, AND ALL

ASSOCIATED CONDUITS AND CONDUCTORS BACK TO

ST-12B.

PROVIDE (3) #2 15KV CABLE AND (1) #6 600V GROUND

CONDUCTOR IN 4" CONDUIT. COMPLETE FEEDER P-93

LOOP BETWEEN ST-17C AND ST-6A.

PROVIDE (3) 350KCMIL 15KV CABLE AND (1) #2 600V

GROUND CONDUCTOR IN EXISTING 4" CONDUIT.

TYPICAL FROM P-88 CIRCUIT BREAKER TO EXISTING

MH-153.

PROVIDE (3) 500KCMIL 15KV CABLE AND (1) #2 600V

GROUND CONDUCTOR. TYPICAL FROM EXISTING MH-153

TO MH-88-05.

SITE 14 SECTIONALIZER. REFER TO POWER PLANT

DRAWING 14PP-EP601.

INTERCEPT CONNECTION POINT AT EXISTING FEEDER

P-68 AND PROVIDE CONDUIT CONNECTION FROM

MH-152 TO EXISTING DUCTBANK FOR FEEDER P-68. SIZE

FEEDER AND CONDUIT TO MATCH EXISTING CONDUIT

AND EXISTING FEEDER P-68.

DEMOLISH EXISTING CONDUIT AND FEEDER P-68

BETWEEN INTERCEPTION POINTS.

PROVIDE 15KV CIRCUIT BREAKER WITH SEL RELAYING

AND INSTRUMENTATION. RE: C1/14ST-EU501.

ANDREW T. GARDNER

OF TE XASS

TATE

ALNOISSE

F O

R P

ENGIN

E

E R

NSEDECIL

130901

XASA

S

TA

TEXAS REGISTERED ENGINEERING FIRM F-2966

10-04-2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

13.8KV, 2000A BUS NO. 2

BUS TIE

P91

TRIP

SEL-351A

SB TSC

3MRCT

1200/5A

50 51 67G

255927

59 27

SEL

2032-4

LA

SPARE

P89P90

TRIP

SEL-351A

SB TSC

3MRCT

1200/5A

50 51 67G

255927

59 27

SEL

2032-4

LA

P88

TRIP

SEL-351A

SB TSC

3MRCT

1200/5A

50 51 67G

255927

59 27

TSP TSP

SEL

2032-6

LA

SPACE

2000/5 MR

VCB BT

2000/5 MR

LINE 2 POTENTIAL

BUS 2 POTENTIAL

NOTES

SCREENED (HALF-TONE) LINES INDICATE

EXISTING EQUIPMENT OR CONNECTIONS.

BOLD LINES INDICATE NEW WORK.

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

KAHSXMATG

17323381

S

IT

E E

L E

C T

R

IC

A L

U T

IL

IT

Y

M A

IN

S

U B

S T

A T

IO

N

D

IA

G R

A M

PARTIAL 26052 MAIN SUBSTATION DIAGRAM

NTSSCALE: B1

A. EXISTING DIAGRAMMATIC INFORMATION SHOWN ON

THIS DRAWING IS DERIVED FROM RECORD DRAWING

SETS. FIELD VERIFY INFORMATION PRIOR TO

COMMENCEMENT OF WORK.

B. REFER TO DRAWINGS 14GI-E-001 THROUGH 14GI-E-003

FOR ELECTRICAL LEGENDS, ABBREVIATIONS, AND

GENERAL NOTES.

26052 MAIN SUBSTATION - FEEDER P-88 CUBICLE

NTSSCALE: C4

ANDREW T. GARDNER

OF TE XASS

TATE

ALNOISSE

F O

R P

ENGIN

E

E R

NSEDECIL

130901

XASA

S

TA

TEXAS REGISTERED ENGINEERING FIRM F-2966

10-04-2024

14GI-E-001 14GI-E-003

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

COMM

COMM

COMM

COMM

COMM

COMM COMM COMM COMM COMM COMM

COMM

COMM

COMM

CO

M

M

COM

M

CO

M

M

CO

M

M

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COM

M

COM

M

COMM

COMM

COMM

COMM

COMM

O M

M

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

O M

M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMMCOMM

COMM

COMM

COMM

C O

M M

C O

M M

COM

M

W W

W W

W W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W W

W W

W W

W W

W

W

W

W

W

W

W

W

W

WWWWWW

W

W W

W W

W

W

W

W W W

W

W W W W

W W W W W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W W W W W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

WWWWW

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W W

W W

W W

W W

W

W

E

E

E

E

E E

E

E

E E E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E E

E

E

E

E

E

E

E E

E

E

E

E

E E

E E

E

EDB

EDB

EDB

E E

E E

E

E

E

E E

E E

D

B EDB EDB EDB EDB EDB EDB

E

E

E E

E E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E E

E

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

S A

N

SAN SAN SAN

SAN

SAN

SAN

S A

N

SAN

SAN

S A

N

SAN

SAN

SAN

SAN

SAN

S A

N

S A

N

S A

N

S A

N

S A

N

S A

N

S A

N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

SA

N

S A

N

SA

N

SA

N

SAN

S A

N

S A

N

S A

N

S A

N

S A

N

S A

N

SAN

SAN

SAN

SAN

SAN

SAN

N

SAN

S A

N

S A

N

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

E

EIS

E

ISE

I S

E

IS

EISEISEISEIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

E

IS

E

IS

E

IS

EIS

EIS

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS EIS

EIS

E

IS

EIS

EIS

E

IS

E

IS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

EIS EIS EIS EIS

EIS

EIS

L D

B L

D B

LDB

LDB

LDBLDB

LDBLDBLDB

L D

B

EMH

EMH

EMHEMH

EMH

EMH

EMH

EM H

TMH

TMH

TMH

CDB

TMH

TMH

TMH

EMH

EMH

C D

B

C D

B C

D B

P D

B

PDB

T

E x

E x

E x

E x

E x

E x

E x

E x

E x

E x

EDBx

EDBx

EDBx

EDBx

EDBx

E D

B E

D B

E D

B

EDB

EDB

EDB

E D

B

X D

B X

D B

X D

B

XDB

X D

B X

D B

XDB XDB

X D

B X

D B

XDB

PANEL B03

ES106

PANEL C03

ES109

PANEL C02

ES108

PANEL B02

ES105

PANEL B01

ES104

PANEL C01

ES107

S TOP

S TOP

STOP

STOP

STOP

STOP

YIELD

STOP

STOP

S D

X

S D

X

SDX

S D

X

SDX

SDX

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W XW X

W XW X

CUX

CUX

CUX

CUX

EU X

EU X

EU XCU X

CU X

CU X

W X

CU X

CU X

CUX

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323386

S

IT

E E

L E

C T

R

IC

A L

K E

Y P

L A

N

SITE ELECTRICAL KEY PLAN

1" = 100'SCALE: A1 0 100 200

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

PANEL B03

ES106

PANEL C03

ES109

PANEL C02

ES108

PANEL B02

ES105

PANEL B01

ES104

PANEL C01

ES107

14GI-E-001

14GI-E-007

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

E D

B E

D B

E D

B E

D B

EDB EDB

EDB EDB EDB E

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

LDBLDBLDBLDBLDBLDBLDB

L

D B

LDBLDBLDBLDBLDBLDBLDBLDBLDBLDB

LDBLDBLDBLDBLDBLDBLDBLDBLDBLDBLDB

LDB

LDB

L D

B L

D B

L D

B

LDB

LDB

LDB

LDB LDB LDB LDB LDB LDB LDB LDB

LD

B

LD

B

TMH

C D

B

TMH

C D

B

CDB CDB CDB CDB CDB CDB CDB CDB CDB

CDB

CDB

CDB

CDB

C C

C

C

C

COMM

C O

M M

C O

M M

XDB XDB XDB XDB XDB XDB XDB XDB XDB

TMH

CMH

CMH

UHH

TPED

STOP

ED

LE

CO

BUILDING

NO. 28007

BUILDING

NO. 28008

SDX

SDX

SDX

SDX

SDX

SDX

SDX

SDX

CO

CO

C O

N C

R E

T E

S

ID

E W

A

LK

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X W X

W X

W X

W X

W X

W X

W X

CUX

CUX

CUX

CUX

CUX

CUX

CUX

CUX

CU X

CU X

CU X

S S

X

S S

X

S S

X

S S

X

S S

X

S S

X

S S

X

CU X

CU X

CU X

CU X

CU X

CU X

CU X

CUX

B

EDB

EDB

EDB

EDB

EDB

EDB

E D

B

EDB

E D

B

E D

B

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

E D

B

EDB

EDB

EDB

EDB

EHH-331 RESTRICTED AREA

BOUNDARY FENCE

EHH-332

EHH-333

P3

PP-14ST61101:10

P4

PP-14ST61101:8

P3

PP-14ST61101:8

P4

PP-14ST61101:10

P3

PP-14ST61101:10

P4

PP-14ST61101:8

P3

PP-14ST61101:8

P4

PP-14ST61101:10

B1

PP-14ST61101:10

P2

PP-14ST61101:8

P2

PP-14ST61101:10

P1

PP-14ST61101:14

P1

PP-14ST61101:12

P1

PP-14ST61101:14

P1

PP-14ST61101:12

EHH-334

CJB-14ST67110

PP-14ST61101:1

A

S T

-E P

A

S T

-E P

A

S T

-E P

C1

14ST-EL502

TYP TO ALL

LIGHT FIXTURES

A1

14ST-EP503 C

S T

-E P

C

S T

-E P

C

S T

-E P

C

S T

-E P

C

S T

-E P

A

S T

-E P

A1

ST-

EP50

A1

14ST-EP503

C314ST-EP503

A

S T

-E P

A

S T

-E P

A1

14ST-EP518

TYP TO

ALL EHH

FDB-14ST67102

PP-14ST61101:5

B1

PP-14ST61101:8

B1

PP-14ST61101:8

B1

PP-14ST61101:10

B1

PP-14ST61101:8

B1

PP-14ST61101:10

B1

PP-14ST61101:10

B1

PP-14ST61101:10

B1

PP-14ST61101:8

B1

PP-14ST61101:8

B1

PP-14ST61101:8

01010101 EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323387

S

IT

E E

L E

C T

R

IC

A L

P L

A N

P

A N

E L

B

SITE ELECTRICAL PLAN - PANEL B01

1" = 20'SCALE: A1 0 20 40

SEE SHEET 14ST-ES105 FOR CONTINUATION

S E

E S

H E

E T

S T

-E S

F

O R

C O

N T

IN

U

A T

IO

N

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR CIVIL LEGEND SEE SHEET 14GI-C-002.

C. ALL POLE LUMINAIRES INSIDE RESTRICTED AREA

FENCE BOUNDARY MUST BE MOUNTED A MINIMUM OF

12'-0" FROM RESTRICTED AREA FENCE.

D. FOR LIGHTING ZONES SEE SHEET

14ST-ES190,14ST-EL501 AND 14ST-EL502 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603 FOR

LIGHTING CONTROL DIAGRAMS, 14ST-EL701 FOR

LUMINAIRE SHCEDULE AND 14ST-EL702 FOR LIGHTING

ZONE SCHEDULE.

E. SITE LIGHTING POLE FOUNDATION MUST BE RAISED.

SEE LUMINAIRE PLATE DETAIL XL-21a ON 14ST-EL501.

F. FOR UTILITY CONNECTION INTERFACE OUTSIDE OF

RESTRICTED FENCE, SEE 14ST-EU SERIES DRAWINGS.

PANEL B03

ES106

PANEL C03

ES109

PANEL C02

ES108

PANEL B02

ES105

PANEL B01

ES104

PANEL C01

ES107

01 LIGHT POLES FOUNDATION LOCATED IN CENTRAL OF

PARKING LOT MUST BE RAISED MINIMUM 3' TO AVOID

DAMAGE AND COLLISION WITH LIGHT POLE. SEE

LUMINAIRE PLATE DETAIL XL-21b ON SHEET 14ST-EL501.

14GI-C-002

14GI-E-001

14GI-E-007

14ST-ES105

T

S

T -E

S

F

S T

-E P

LD

W X

S T

-E P

A

S

T -E

P

S

T -E

P

A1

14ST-EP503

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

LD

A1

ST-

EP50

14ST-EP503

LD

C34ST-EP503

14ST-EP50

B

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

14ST-EP518

14ST-EL501

14ST-EL501

14ST-EL501

4ST-EL50214ST-EL50

14ST-EL502 ,

14ST-EL601 14ST-EL603

14ST-EL701 ,

14ST-EL702

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

LD

B

L D

B L

D B

L D

B L

D B

L D

B L

D B

L D

B L

D B

L D

B

EMH

EMHEMH

P

D B

P D

B

EMH

TMH

TMH

EMH

C D

B C

D B

C D

B C

D B

C D

B C

D B

CDB CDBCDB

C D

B

P D

B P

D B

P D

B P

D B

P D

B P

D B

P D

B P

D B

PDB PDB PDB PDB PDB

PDB

W

W W

W W

WWW W

W W

W W

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

TP

TPED

BUILDING

NO. 28053

BUILDING

NO. 28054

BUILDING

NO. 28069

BUILDING

NO. 28070

SS X

SSX

SSX

SS X

SS X

SSX

SS X

SSX

S

STEPS

M

C O

N C

R E

T E

S

ID

E W

A L

K

C O

N C

R E

T E

S

ID

E W

A

LK

C O

N C

R E

T E

S

ID

E W

A

LK

C O

N C

R E

T E

S

ID

E W

A L

K

CU X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

X

S S

X

S S

X

S S

X

S S

X

S S

X

EDB

EDB

E D

B E

D B

E D

B E

D B

E D

B E

D B

E D

E D

B E

D B

E D

B E

D B

E D

B E

D B

E D

B E

D B

EHH-301

EMH-103B

EMH-103A

EMH-102A

COMMAND

CENTER

POWER

PLANT

P1

PP-14ST61101:16

P1

PP-14ST61101:18

P1

PP-14ST61101:16

P1

PP-14ST61101:18

P1

PP-14ST61101:16

P1

PP-14ST61101:18

EMH-202

SEE SHEET 14CC-EP104

FOR CONTINUATION

SEE SHEET 14PP-EP102

FOR CONTINUATION

C1

14ST-ES402

B3

14ST-EP513

CJB-14ST67109

PP-14ST61101:7

EHH-311

EMH-201

B1

14ST-EP511

B3

14ST-EP512

B3

14ST-EP512

RESTRICTED AREA

BOUNDARY FENCE

PDB 40

P D

B

P D

B

EDB 20

EDB 2

E D

B

XFMR-14ST61101

A

S T

-E P

C3

14ST-EP501

C3

14ST-EP505

C3

14ST-EP501

C3

14ST-EP501

C

S T

-E P

U14ST-2004

U

S

T -2

U

S T

- 2

U

S

T -2

U14ST-1002A

U14ST-1004A

U14ST-1005A

U14ST-1004B

U14ST-1005B

CJB-14ST67110

PP-14ST61101:1

C3

14ST-EP501

A3

14ST-EL502

TYP TO ALL

LIGHT FIXTURES

U14ST-3001

A3

14ST-EP503

A3

14ST-EP503

A1

14ST-EP503

A1

14ST-EP503

C3

14ST-E

P503

B1

14ST-EP513

C1

14ST-EP503

A1

14ST-EP518

TYP TO

ALL EHH

U14ST-1003A

C3

14ST-EP501

C3

14ST-EP505

A1

14ST-EP501

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323388

S

IT

E E

L E

C T

R

IC

A L

P L

A N

P

A N

E L

B

SITE ELECTRICAL PLAN - PANEL B02

1" = 20'SCALE: A1 0 20 40

SEE SHEET 14ST-ES106 FOR CONTINUATION

SEE SHEET 14ST-ES104 FOR CONTINUATION

S E

E S

H E

E T

S T

-E S

F

O R

C O

N T

IN

U

A T

IO

N

PANEL B03

ES106

PANEL C03

ES109

PANEL C02

ES108

PANEL B02

ES105

PANEL B01

ES104

PANEL C01

ES107

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR CIVIL LEGEND SEE SHEET 14GI-C-002.

C. ALL POLE LUMINAIRES INSIDE RESTRICTED AREA

FENCE BOUNDARY MUST BE MOUNTED A MINIMUM OF

12'-0" FROM RESTRICTED AREA FENCE.

D. FOR LIGHTING ZONES SEE SHEET

14ST-ES190,14ST-EL501 AND 14ST-EL502 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603 FOR

LIGHTING CONTROL DIAGRAMS, 14ST-EL701 FOR

LUMINAIRE SHCEDULE AND 14ST-EL702 FOR LIGHTING

ZONE SCHEDULE.

E. SITE LIGHTING POLE FOUNDATION MUST BE RAISED.

SEE LUMINAIRE PLATE DETAIL XL-21a ON 14ST-EL501.

F. SEE SHEET 14ST-ES190 FOR LIGHTING ZONES.

G. SEE SHEET 14ST-EL702 FOR LIGHTING ZONE

SCHEDULE.

H. FOR UTILITY CONNECTION INTERFACE OUTSIDE OF

RESTRICTED FENCE, SEE 14ST-EU SERIES DRAWINGS.

14GI-C-002

14GI-E-001

14GI-E-007

14ST-ES104

14ST-ES106

T

S

T -E

S

F

14ST-ES190

B

14ST-ES402

S T

-E P

14ST-EP501

C3CC4ST-EP501

14ST-EP50

14ST-EP501

S T

-E P

1 14ST-EP501

14ST-EP501

14ST-EP501

14ST-EP503

L

D W14ST-EP503

4ST-EP50314ST-EP50

E4ST-EP50314ST-EP50

C3

14ST-E

P503

4ST-EP50314ST-EP50

14ST-EP505

14ST-EP505

14ST-EP511

14ST-EP512

14ST-EP512

14ST-EP513

4ST-EP51314ST-EP51

4ST-EP51814ST-EP51

14ST-EL501

14ST-EL501

4ST-EL50214ST-EL50

14ST-EL502 ,

14ST-EL601 14ST-EL603

14ST-EL701 ,

14ST-EL702

14ST-EL702

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

XDB

X D

B X

D B

X D

B X

D B

X D

B X

D B

XDBXDBXDBXDBXDBXDBXDBXDBXDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

D B

E D

B E

D B

E D

B E

D B

E D

B E

D B

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

E

IS

EIS

EIS

E

IS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

L D

B L

D B

L D

B L

D B

LDB LDB LDB LDB LDB LDB LDB

E D

B

EMH

EDBEDBEDB

RESTRICTED AREA

BOUNDARY FENCE

EHH-308

P1

PP-14ST61101:16

P1

PP-14ST61101:18

P1

PP-14ST61102:20

P1

PP-14ST61102:12 P1

PP-14ST61102:14

SECT-14ST61101

EMH-102B

POWER

PLANT

SEE SHEET 14PP-EP102

FOR CONTINUATION

B3

14ST-EP511

FDB-14ST67108

PP-14ST61101:9

CJB-14ST67107

PP-14ST61102:1

EHH-307

E D

B

EDB 30

C3

14ST-EP501

C

S T

-E P

EHH-310 U14ST-1002A

U14ST-1001

U14ST-3002B

U14ST-1003B

EMERGENCY

ENTRANCE/ EXIT

EHH-309

GOC-14ST56102

PP-14ST61101:9

C1

14ST-EP503 LIGHT FIXTURES

TYP TO ALL

A1

14ST-EP503

A1

14ST-EP503

C3

14ST-E

P503

C1

14ST-EP503

C1

14ST-E

P503

A

S T

-E P

A

S T

-E P

A

S T

-E P

3 A

S T

-E P

C1

14ST-EP503

A3

14ST-EL502 LIGHT FIXTURES

TYP TO ALL

C3

14ST-TY507

C3

14ST-E

P503

A3

14ST-ES402

A1

14ST-EP518

TYP TO

ALL EHH

C3

14ST-EP501

C

S T

-E P

W

W W

WW

W

W

W

EBXTRN

SSX

SS X

S D

X

S D

X

S

SSX

SS X

SS X

SS X

SSX

SSX

SSX

SSX

SSX

SSX

W X

W X

W X

W X

W X

W X

EU X

EU X

EU X

EU X

CU X

CU X

CU X

CU X

CU X

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323389

S

IT

E E

L E

C T

R

IC

A L

P L

A N

P

A N

E L

B

SITE ELECTRICAL PLAN - PANEL B03

1" = 20'SCALE: A1 0 20 40

SEE SHEET 14ST-ES105 FOR CONTINUATION

S E

E S

H E

E T

S T

-E S

F

O R

C O

N T

IN

U

A T

IO

N

PANEL B03

ES106

PANEL C03

ES109

PANEL C02

ES108

PANEL B02

ES105

PANEL B01

ES104

PANEL C01

ES107

01 REFER TO SHEET 14ST-EU109 FOR CONTINUATION.

02 REFER TO SHEET 14ST-TY507 DETAILING COMBINED

FIELD DEVICE BOX (FDB) AND CAMERA JUNCTION BOX

(CJB) INSTALLED ON UNISTRUT SUPPORT RACK. FDB

CONTAINS FEED FROM UPSTREAM POWER PANEL

PP-14ST61101, AND CONTAINS STEP-DOWN

TRANSFORMER AND INTERIOR DISTRIBUTION TO

POWER CJB AND GATE OPERATOR CONTROLLER (GOC).

03 GOC FED VIA FDB-14ST67108 ENCLOSURE FROM

POWER PANEL LOCATED ON SHEETS 14ST-ES105 AND

14ST-ES402.

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR CIVIL LEGEND SEE SHEET 14GI-C-002.

C. ALL POLE LUMINAIRES INSIDE RESTRICTED AREA

FENCE BOUNDARY MUST BE MOUNTED A MINIMUM OF

12'-0" FROM RESTRICTED AREA FENCE.

D. FOR LIGHTING ZONES SEE SHEET

14ST-ES190,14ST-EL501 AND 14ST-EL502 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603 FOR

LIGHTING CONTROL DIAGRAMS, 14ST-EL701 FOR

LUMINAIRE SHCEDULE AND 14ST-EL702 FOR LIGHTING

ZONE SCHEDULE.

E. SITE LIGHTING POLE FOUNDATION MUST BE RAISED.

SEE LUMINAIRE PLATE DETAIL XL-21a ON 14ST-EL501.

F. FOR UTILITY CONNECTION INTERFACE OUTSIDE OF

RESTRICTED FENCE, SEE 14ST-EU SERIES DRAWINGS.

14GI-C-002

14GI-E-001

14GI-E-007

14ST-EU109

14ST-ES105

14ST-ES105

T

S

T -E

S

F

14ST-ES402

14ST-ES402

14ST-EP501 ED

S T

-E P

14ST-EP501

14ST-EP503

U4ST-EP50314ST-EP50

14ST-EP503

LDB

C3C3C

14ST-E

P503

C1

14ST-EP503

XDBC1C1C1C

14ST-E

P50

4ST-E

P503

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

S T

-E P

S

T -E

P

XDBC1XDBDB

14ST-EP50

4ST-EP503

D B

C3

BB

C

14ST-E

P503

S T

-E P

4ST-EP51114ST-EP51

14ST-EP518

14ST-EL501

14ST-EL501

4ST-EL50214ST-EL50

14ST-EL502 ,

14ST-EL601 14ST-EL603

14ST-EL701 ,

14ST-EL702

4ST-TY50714ST-TY50

14ST-TY507

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

EDB EDB EDB EDB

EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB

EISEISEISEISEISEISEISEISEISEISEISEISEISEISEISEIS

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

EIS EIS EIS EIS EIS EIS EIS EIS

LDBLDBLDBLDBLDB

L D

B

LDB

TMH

P D

B

C D

B C

D B

C D

B C

D B

C D

B C

D B

C D

B

FUTURE GENERAL

PURPOSE WAREHOUSE

P2

PP-14ST61101:10

EHH-335

P3

PP-14ST61101:8

P4

PP-14ST61101:10

P1

PP-14ST61101:14

P1

PP-14ST61101:12

ACCESS CONTROL POINT

(SEE SHEET 14AC-EP101)

16+00

CAP AND LOCATE

FOR FUTURE USE

A3

14ST-EL502

TYP TO ALL

LIGHT FIXTURES

A

S T

-E P

C1

14ST-EP503

C

S T

-E P

A

S T

-E P

A

S T

-E P

RESTRICTED AREA

BOUNDARY FENCE

C

S T

-E P

C3

14ST-EP503

C

S T

-E P

A1

14ST-EP518

TYP TO

ALL EHH

U14ST-2010

C O

M M

C O

M M

C O

M M

XDB XDB XDB XDB XDB XDB XDB

SPOTLIGHT(4)

CPAD

EHH

EHH

EHH

UHH

CMH

GTAHH

STOP

STOP

STOP

CLP

S S

X S

S X

S S

X S

S X

S S

X S

S X

S S

X

SSX

SSX

S D

X S

D X

SDXSDX

S D

X

SDX

SDX

SDX

SDX

SDX

SDX

SDX

SDX

S D

X S

D X

S D

X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X W X W X W X W X W X W XW X W X W X W X W X W X W X

CUXCUXCUXCUX

CUX

CUX

CUX

CUX

CU X

CU X

CUX

CUX

CUX

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323390

S

IT

E E

L E

C T

R

IC

A L

P L

A N

P

A N

E L

C

SITE ELECTRICAL PLAN - PANEL C01

1" = 20'SCALE: A1 0 20 40

SEE SHEET 14ST-ES108 FOR CONTINUATION

S E

E S

H E

E T

S T

-E S

F

O R

C O

N T

IN

U

A T

IO

N

PANEL B03

TS106

PANEL C03

TS109

PANEL C02

TS108

PANEL B02

TS105

PANEL B01

TS104

PANEL C01

TS107

01 CAP AND LOCATE CONCRETE ENCASED DUCTBANK

FOR FUTURE TIE-IN TO GENERAL PURPOSE

WAREHOUSE AND MISSION SUPPORT LOOP.

02 LIGHT POLES FOUNDATION LOCATED IN CENTRAL OF

PARKING LOT MUST BE RAISED MINIMUM 3' TO AVOID

DAMAGE AND COLLISION WITH LIGHT POLE. SEE

LUMINAIRE PLATE DETAIL XL-21b ON SHEET

14ST-EL501.

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR CIVIL LEGEND SEE SHEET 14GI-C-002.

C. ALL POLE LUMINAIRES INSIDE RESTRICTED AREA

FENCE BOUNDARY MUST BE MOUNTED A MINIMUM OF

12'-0" FROM RESTRICTED AREA FENCE.

D. FOR LIGHTING ZONES SEE SHEET

14ST-ES190,14ST-EL501 AND 14ST-EL502 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603 FOR

LIGHTING CONTROL DIAGRAMS, 14ST-EL701 FOR

LUMINAIRE SHCEDULE AND 14ST-EL702 FOR LIGHTING

ZONE SCHEDULE.

E. SITE LIGHTING POLE FOUNDATION MUST BE RAISED.

SEE LUMINAIRE PLATE DETAIL XL-21a ON 14ST-EL501.

F. FOR UTILITY CONNECTION INTERFACE OUTSIDE OF

RESTRICTED FENCE, SEE 14ST-EU SERIES DRAWINGS.

14GI-C-002

14GI-E-001

14GI-E-007

T

S

T -E

S

F

14ST-ES108

S T

-E P

14ST-EP503

S T

-E P

S T

-E P

DBBB 1

S T

-E P

S T

-EE

P

14ST-EP503

S T

-E P

4ST-EP51814ST-EP51H

14ST-EL501

14ST-EL501

14ST-EL501

14ST-EL502S

XX

14ST-EL502 ,

14ST-EL601 14ST-EL603

14ST-EL701 ,

14ST-EL702

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

L D

B L

D B

L D

B L

D B

L D

B L

D B

L D

B L

D B

L D

B L

D B

L D

B L

D B

L D

B

LDB

EMH

EMH

TMH

EMH

PDB

P D

B P

D B

CDBCDB

LDB

C D

B C

D B

C D

B C

D B

C D

B C

D B

CDBCDB

P D

B

PDB PDBPDB

P D

B P

D B

P D

B

P D

B P

D B

C D

B

T

C D

B C

D B

C D

B

C D

B

W

SS

W W

W

WW

F

SS SS SS SS SS

S S

S S

S S

S S

S S

S

SW

SS SS

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

XDBXDB

X D

B

UHH

EMH

CLP

S S

X S

S X

S S

X S

S X

S S

X S

S X

S S

X S

S X

S S

X

SSX

SSX

SDX SDX SDX

S D

X S

D X

S D

X S

D X

S D

X S

D X

S D

X S

D X

S D

X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

W X

EMH-203

EHH-302

EHH-303

RESTRICTED AREA

BOUNDARY FENCE

FUEL

STORAGE

PRIMARY VEHICLE

ENTRANCE/ EXIT

COMMAND

CENTER

P1

PP-14ST61102:10

P1

PP-14ST61102:8

P1

PP-14ST61102:10

P1

PP-14ST61102:8

P1

PP-14ST61102:10

P1

PP-14ST61102:18

EMH-205

EMH-204

ANTENNA

TOWER

FDB-14ST67104

PP-14ST61102:3

B1

14ST-ES514

EHH-304

CJB-14ST67105

PP-14ST61102:5

B1

14ST-EP515

PDB 40

P D

B

P D

B

A

S T

-E P

C3

14ST-EP505

C1

14ST-E

P50

C3

14ST-EP501

U14ST-2004

U

S

T -2

U

S

T -2

U

S

T -2

GOC-14ST56101

PP-14ST61102:3

C

S

T- E

P

C

S T

-E P

C3

14ST-EP503

A1

14ST-EP503

C

S

T-

EP

A1

14ST-EP503

A3

14ST-EL502

TYP TO ALL

LIGHT FIXTURES

B3

14ST-EP514

A1

14ST-EP503

A3

14ST-EP503

C1

14ST-EP503

A3

14ST-EP503

A1

14ST-EP518

TYP TO

ALL EHH

C1

14ST-E

P505

C1

14ST-EP501

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323391

S

IT

E E

L E

C T

R

IC

A L

P L

A N

P

A N

E L

C

SITE ELECTRICAL PLAN - PANEL C02

1" = 20'SCALE: A1 0 20 40

SEE SHEET 14ST-ES109 FOR CONTINUATION

SEE SHEET 14ST-ES107 FOR CONTINUATION

S E

E S

H E

E T

S T

-E S

F

O R

C O

N T

IN

U

A T

IO

N

PANEL B03

ES106

PANEL C03

ES109

PANEL C02

ES108

PANEL B02

ES105

PANEL B01

ES104

PANEL C01

ES107

01 REFER TO SHEET 14ST-TY507 DETAILING COMBINED

FIELD DEVICE BOX (FDB) AND CAMERA JUNCTION BOX

(CJB) INSTALLED ON UNISTRUT SUPPORT RACK. FDB

CONTAINS FEED FROM UPSTREAM POWER PANEL

PP-14ST61102, AND CONTAINS STEP-DOWN

TRANSFORMER AND INTERIOR DISTRIBUTION TO

POWER CJB AND GATE OPERATOR CONTROLLER (GOC).

02 GOC FED VIA FDB-14ST67104 ENCLOSURE FROM

POWER PANEL LOCATED ON SHEETS 14ST-ES109 AND

14ST-ES402.

03 PROVIDE 1" UNDERGROUND CONDUIT WITH A

DEDICATED CIRCUIT FROM MPC-14UL61102 TO A NEMA

5-20R WEATHERPROOF GFCI QUAD RECEPTACLE

WITHIN AMI WATER METER INTERFACE ENCLOSURE.

REFER TO A3/14ST-TS512.

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR CIVIL LEGEND SEE SHEET 14GI-C-002.

C. ALL POLE LUMINAIRES INSIDE RESTRICTED AREA

FENCE BOUNDARY MUST BE MOUNTED A MINIMUM OF

12'-0" FROM RESTRICTED AREA FENCE.

D. FOR LIGHTING ZONES SEE SHEET

14ST-ES190,14ST-EL501 AND 14ST-EL502 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603 FOR

LIGHTING CONTROL DIAGRAMS, 14ST-EL701 FOR

LUMINAIRE SHCEDULE AND 14ST-EL702 FOR LIGHTING

ZONE SCHEDULE.

E. SITE LIGHTING POLE FOUNDATION MUST BE RAISED.

SEE LUMINAIRE PLATE DETAIL XL-21a ON 14ST-EL501.

F. FOR UTILITY CONNECTION INTERFACE OUTSIDE OF

RESTRICTED FENCE, SEE 14ST-EU SERIES DRAWINGS.

14GI-C-002

14GI-E-001

14GI-E-007

T

S

T -E

S

F

14ST-ES107

14ST-ES109

14ST-ES109

S 1

S T

-E P

ANTENN

C1

14ST-E

P50

14ST-EP501

C1C

14ST-EP501

C

CC

S T-

E P

C

S T

-E P

S

T -E

P

14ST-EP503

14ST-EP503

X D

B X

DC

C

S

T-

EP

14ST-EP503

14ST-EP503

14ST-EP503

14ST-EP503

14ST-EP503

14ST-EP505

C1CC

14ST-E

P505

14ST-EP514

14ST-EP515

4ST-EP51814ST-EP51H

14ST-EL501

14ST-EL501

14ST-EL502S

14ST-EL502 ,

14ST-EL601 14ST-EL603

14ST-EL701 ,

14ST-EL702

/14ST-TS512

14ST-TY507

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

WW

W W

W W

W

W

W

W W

X D

B X

D B

X D

B X

D B

X D

B

XDBXDBXDBXDBXDBXDB

PAVILION

S D

X S

D X

S D

X S

D X

S D

X S

D X

C O

N C

R E

T E

S

ID

E W

A L

K

CONCRETE SIDEWALK

W X

W X

EU X

L D

B L

D B

L D

B L

D B

L D

B

LDB LDB LDB LDB LDB

P D

B

PDB

EMH

L D

B L

D B

L D

B

P D

B P

D B

PDBPDBPDBPDB

C D

B

C D

B C

D B

LDB LDB LDB

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

EIS

E

IS

E

IS

E

IS

E

IS EIS

EIS

EIS

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

RESTRICTED AREA

BOUNDARY FENCE

FUEL

UNLOADING

FUEL STORAGE

(FUTURE)

XFMR-14ST61102

FUEL

STORAGE

EHH-306

P1

PP-14ST61102:12

P1

PP-14ST61102:14

P1

PP-14ST61102:12

P1

PP-14ST61102:10

P1

PP-14ST61102:8

FUEL STORAGE

(FUTURE)

EMH-206

EHH-351

A1

14ST-ES401

A1

14ST-ES402

22+0022+51

SEE SHEET 14PP-EP104

FOR CONTINUATION

B3

14ST-EP515

CJB-14ST67106

PP-14ST61102:7

PDB 40

P D

B

C

S T

-E P

C

S T

-E P

A3

14ST-EP501

U

S

T -2

U14ST-2009

U14ST-2101

U14ST2008

A3

14ST-EL502

TYP TO ALL

LIGHT FIXTURES

A

S T

-E P

A

S T

-E P

3 A3

14ST-EP503

A3

14ST-EP503

EHH-305

C

S T

-E P

C1

14ST-EP503

C

S T

-E P

C

S T

-E P

U14ST-3002

C

S

T- E

P

A

S T

-E P

A1

14ST-EP518

TYP TO

ALL EHH

U14ST-0001

PP-14PP61141B:19

WP/GFCI

C

S T

-E P

EDBx

E D

B x

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323392

S

IT

E E

L E

C T

R

IC

A L

P L

A N

P

A N

E L

C

SITE ELECTRICAL PLAN - PANEL C03

1" = 20'SCALE: A1 0 20 40

SEE SHEET 14ST-ES108 FOR CONTINUATION

S E

E S

H E

E T

S T

-E S

F

O R

C O

N T

IN

U

A T

IO

N

PANEL B03

TS106

PANEL C03

TS109

PANEL C02

TS108

PANEL B02

TS105

PANEL B01

TS104

PANEL C01

TS107

01 PROVIDE A 200A LOAD BANK TERMINATION BOX

WITHIN NEMA 4XSS ENCLOSURE AND AN ACCESS

DOOR POINTED IN THE DIRECTION TOWARDS THE

LOAD BANK, WHERE REEL CONDUCTORS (PROVIDED

WITH THE LOAD BANK) CAN ENTER AND TERMINATE IN

THE ENCLOSURE. LOAD BANK TERMINATION BOX

TERMINATION LUGS SHALL BE MATCHED WITH CABLE

FEEDER FROM GENERATOR SWITCHGEAR IN POWER

PLANT AND THE CONDUCTORS PROVIDED WITH THE

LOAD BANK.

02 FIELD ROUTE 1" UNDERGROUND CONDUIT TO AMI

WATER METER ENCLOSURE.

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR CIVIL LEGEND SEE SHEET 14GI-C-002.

C. ALL POLE LUMINAIRES INSIDE RESTRICTED AREA

FENCE BOUNDARY MUST BE MOUNTED A MINIMUM OF

12'-0" FROM RESTRICTED AREA FENCE.

D. FOR LIGHTING ZONES SEE SHEET

14ST-ES190,14ST-EL501 AND 14ST-EL502 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603 FOR

LIGHTING CONTROL DIAGRAMS, 14ST-EL701 FOR

LUMINAIRE SHCEDULE AND 14ST-EL702 FOR LIGHTING

ZONE SCHEDULE.

E. SITE LIGHTING POLE FOUNDATION MUST BE RAISED.

SEE LUMINAIRE PLATE DETAIL XL-21a ON 14ST-EL501.

F. FOR UTILITY CONNECTION INTERFACE OUTSIDE OF

RESTRICTED FENCE, SEE 14ST-EU SERIES DRAWINGS.

14GI-C-002

14GI-E-001

14GI-E-007

T

S

T -E

S

F

14ST-ES108

4ST-ES40114ST-ES40

14ST-ES402

S T

-E P

14ST-EP501

B

S T

-E P

S

T -E

P

T6110

S T

-E P

S T

-E P

DB

S T

-E P

14ST-EP503

14ST-EP503

W

S T

-E P

14ST-EP503

S T

-E P

S T

-E P

LDB

C

S

T- E

P

S T

-E P

S

T -E

P

4ST-EP51514ST-EP51

4ST-EP51814ST-EP51

14ST-EL501

14ST-EL501

4ST-EL50214ST-EL50S

14ST-EL502 ,

14ST-EL601 14ST-EL603

14ST-EL701 ,

14ST-EL702

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

EDB

EDB

EDB

EDB

EDB

E D

B EDB EDBEIS

EIS

EIS

EIS

EIS

EIS

E

IS

E

IS

EIS

EIS

EIS

EIS

EIS

EIS

E

IS

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

EIS EIS EIS EIS EISEIS

EIS

EIS

EIS

EIS

EIS

E

IS

E

IS

EIS

EIS

EIS

EIS

EIS

EIS

E

IS

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

EIS EIS EIS EIS EIS

L D

B L

D B

L D

B L

D B

L D

B L

D B

LDBLDBLDBLDB

L D

B L

D B

L D

B L

D B

L D

B

LDB LDB LDB

LDBLDBLDBLDB

LDBLDBLDBLDBLDB

LDB

L D

B

LDB

LDB

EMH

EMH

EMHEMH

EMH

EMH

EMH

EMH

EDB

L D

B

EMH

EMH

PDB

P D

B

P D

B P

D B

P D

B

PDB PDB

P D

B

PDB

LDB

LIGHTING ZONE 5 FOR

PARKING LOT

RESTRICTED AREA BOUNDARY FENCE LIGHTING

ZONE 1. (SEE NOTES 01 & 02, TYPICAL)

RESTRICTED AREA BOUNDARY FENCE LIGHTING

ZONE 2. (SEE NOTES 01 & 02, TYPICAL)

RESTRICTED AREA BOUNDARY FENCE LIGHTING

ZONE 3. (SEE NOTES 01 & 02, TYPICAL)

RESTRICTED AREA BOUNDARY FENCE LIGHTING

ZONE 4. (SEE NOTES 01 & 02, TYPICAL)

LIGHTING ZONE 7.4 FOR POWER PLANT BUILDING

WITHIN RESTRICTED AREA BOUNDARY FENCE.

(SEE NOTES 02 & 03 TYPICAL)

LIGHTING ZONE 8 FOR FUEL UNLOADING STATION.

(SEE NOTES 02 & 03, TYPICAL)

LIGHTING ZONE 9 FOR ACCESS CONTROL

CANOPY (SEE NOTES 02 & 03, TYPICAL)

E D

B E

D B

E D

B E

D B

E D

B E

D B

E D

B

E D

B

EDB

EDB

EDB

EDB

EDB

EDB

STOP

STOP

STOP

D X

S D

X

SDX

S D

X S

D X

S D

X S

D X

SDX

SDX

SDX

SDX

SDX

EU X

EU X

EU X

EU X

LIGHTING ZONE 10 FOR NORTH-WEST

ACCESS GATE (SEE NOTES 01 & 02,

TYPICAL)

LIGHTING ZONE 11 FOR SOUTH-WEST

ACCESS GATE (SEE NOTES 01 & 02,

TYPICAL)

LIGHTING ZONE 7.1 FOR POWER PLANT

BUILDING WITHIN RESTRICTED AREA

BOUNDARY FENCE. (SEE NOTES 02 & 03

TYPICAL)

LIGHTING ZONE 7.2 FOR POWER PLANT BUILDING

WITHIN RESTRICTED AREA BOUNDARY FENCE.

(SEE NOTES 02 & 03 TYPICAL)

LIGHTING ZONE 6.1 FOR COMMAND CENTER

BUILDING WITHIN RESTRCITED AREA BOUNDARY

FENCE. (SEE NOTES 02 & 03, TYPICAL)

LIGHTING ZONE 6.2 FOR COMMAND CENTER

BUILDING WITHIN RESTRCITED AREA BOUNDARY

FENCE. (SEE NOTES 02 & 03, TYPICAL)

LIGHTING ZONE 6.3 FOR COMMAND CENTER

BUILDING WITHIN RESTRCITED AREA BOUNDARY

FENCE. (SEE NOTES 02 & 03, TYPICAL)

LIGHTING ZONE 7.3 FOR POWER PLANT BUILDING

WITHIN RESTRICTED AREA BOUNDARY FENCE.

(SEE NOTES 02 & 03 TYPICAL)

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323393

S

IT

E L

IG

H

T

IN

G P

LA

N

L

IG

H

T

IN

G Z

O N

E

SITE LIGHTING PLAN - LIGHTING ZONE

1" = 50'SCALE: A1 0 50 100

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR CIVIL LEGEND SEE SHEET 14GI-C-002.

C. FOR OVERALL SITE LAYOUT PLAN, SEE SHEET

14ST-ES100.

D. SEE SITE DRAWINGS, SHEET 14ST-ES104 THROUGH

14ST-ES109.

E. FOR PANEL SCHEDULES SEE SHEET 14ST-EP701.

F. FOR LIGHTING CONTRACTOR SCHEMATICS SEE SHEET

14ST-EL601 THROUGH 14ST-EL603, 14CC-EL602 AND

14CC-EL603, 14PP-EL501 AND 14PP-EL502.

G. FOR ONE LINE DIAGRAM SEE SHEET 14ST-ES601.

H. LIGHTING ZONE CONTROL FOR THE COMMAND

CENTER, AND POWER PLANT CONSISTS OF EXTERIOR

BUILDING MOUNTED FIXTURES.

I. SEE 14ST-EL702 FOR LIGHTING ZONE SCHEDULE.

01 SECURITY SYSTEM MUST CONTROL LIGHTS AS

DEFINED BY THESE RESTRICTED AREA BOUNDARY

FENCE LIGHTING ZONES FROM THE SECURITY

CONTROL CENTER (LOCATED INSIDE COMMAND

CENTER). REFER TO SITE SECURITY SHEETS AND SEE

SITE SECURITY KEYPLAN FOR SECURITY ZONES.

RESTRICTED AREA BOUNDARY FENCE LIGHTING

PROVIDES ILLUMINATION FOR SECURITY CCTV

IMMEDIATE VISUAL ASSESSMENT (IVA) AND HUMAN

(IVA).

02 SEE ELECTRICAL SITE DRAWINGS FOR CIRCUIT

NUMBERS AND PANEL SCHEDULES TO IDENTIFY

INDIVIDUAL FIXTURES CORRESPONDING TO LIGHTING

ZONE AND LIGHTING CONTACTOR.

03 SECURITY SYSTEM MUST CONTROL LIGHTS AS

DEFINED BY THESE LIGHTING ZONES FROM THE

COMMAND CENTER. LIGHTING ZONES MUST BE GIVEN

NAME AND NUMBER OF RESPECTIVE BUILDING OR

ENCLOSURE. LIGHTING FOR BUILDINGS &

ENCLOSURES PROVIDES ILLUMINATION FOR SECURITY,

MAINTENANCE AND SAFETY.

14GI-C-002

14GI-E-001

14GI-E-007

14ST-ES100

14ST-ES104

14ST-ES109

14ST-EP701

14ST-EL601 14ST-EL603

14ST-EL702

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

LE

V A

T

IO

N I

N F

E E

T

E

LE

V A

T

IO

N I

N F

E E

T

STATION

EDB 20 STA 9+75 TO STA 11+50

9+75 10+00 10+50 11+00 11+50

E

LE

V A

T

IO

N I

N F

E E

T

E

LE

V A

T

IO

N I

N F

E E

T

STATION

EDB 21 STA 9+75 TO STA 11+00

9+75 10+00 10+50 11+00

E

LE

V A

T

IO

N I

N F

E E

T

E

LE

V A

T

IO

N I

N F

E E

T

STATION

EDB 30 STA 10+00 TO STA 11+50

10+00 10+50 11+00 11+50

E

LE

V A

T

IO

N I

N F

E E

T

E

LE

V A

T

IO

N I

N F

E E

T

STATION

EDB 31 STA 9+75 TO STA 11+00

9+75 10+00 10+50 11+00

1" = 20'A1 HORIZONTAL SCALE: 1" = 4'VERTICAL SCALE:

1" = 20'C1 HORIZONTAL SCALE: 1" = 4'VERTICAL SCALE:

1" = 20'A3 HORIZONTAL SCALE: 1" = 4'VERTICAL SCALE:

1" = 20'C3 HORIZONTAL SCALE: 1" = 4'VERTICAL SCALE:

E D

B

M H

S T

A

.8

R

IM

.1

IN

V

IN

S

E

.0

IN

V

IN

N

W

.2

11.5"x20" EDB

E D

B

M H

S T

A

.1

R

IM

.3

IN

V

IN

N

W

.0

IN

V

O U

T N

E

.0

E D

B

M H

S T

A

.8

R

IM

.7

IN

V

IN

S

E

.2

IN

V

O U

T N

E

.2

11.5"x20" EDB

FINISHED GRADE

FINISHED

GRADE

FINISHED

GRADE

FINISHED

GRADE

EXISTING GRADE

EXISTING

GRADE

EXISTING

GRADE

EXISTING GRADE

11.5"x20" EDB

11.5"x20" EDB

11.5"x20" EDB

S T

A

.0

S

IT

E

S

T O

R M

IN

V

E L

.6

E D

B

M H

S T

A

.7

R

IM

.1

IN

V

IN

S

E

.2

IN

V

O U

T N

E

.2

STA: 10+32.70

ELEV= 503.50

STA: 10+00.00

ELEV= 501.00

STA: 10+03.00

ELEV= 502.83

STA: 11+23.75

ELEV= 501.50

STA: 10+46.21

ELEV= 501.50

STA: 10+00.00

ELEV= 500.25

STA: 10+55.84

ELEV= 503.5011

.5 "x

" E

DB

11.5"x20" EDB

S T

A

.0

S

IT

E

W

A T

E R

IN

V

E L

.4

S E

C T

-1

S T

S

T A

.5

R

IM

.1

IN

V

IN

N W

.1

IN

V

O

U T

S E

.5

IN

V

O

U T

S W

.1

STA: 10+00.00

ELEV= 502.57

S T

A

.7

P D

B

IN

V

E L

.0

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323394

S

IT

E E

L E

C T

R

IC

A L

P R

O F

IL

E

A. FOR ELECTRICAL GENERAL NOTES,

LEGEND, AND ABBREVIATIONS, SEE SHEET

14GI-E-001 THROUGH 14GI-E-007.

B. CONTRACTOR MUST VERIFY ELECTRICAL

CODE REQUIREMENTS AND

SPECIFICATIONS. CONTRACTOR MUST

COORDINATE WITH OTHER UTILITY

ROUTINGS.

8'4'0

40'20'0

VERTICAL

HORIZONTAL

10/04/24 10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

V A

T

IO

N I

N F

E E

T

STATION

PDB 40 STA 10+00 TO STA 14+50

10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50

E

LE

V A

T

IO

N I

N F

E E

T

STATION

PDB 40 STA 14+50 TO STA 19+00

14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00

1" = 20'A1 HORIZONTAL SCALE: 1" = 4'VERTICAL SCALE:

1" = 20'C1 HORIZONTAL SCALE: 1" = 4'VERTICAL SCALE:

P D

B

M H

S T

A

.7

R

IM

.0

IN

V

IN

S

W

.2

IN

V

O U

T S

E

.2

11.5"x20" PDB_

P D

B

M H

S T

A

.5

R

IM

.6

IN

V

IN

S

E

.6

IN

V

O U

T N

E

.6

FINISHED GRADE

FINISHED GRADE

EXISTING GRADE

EXISTING GRADE

11.5"x20" PDB_

24" x 24" PDB_

S T

A

.1

S

IT

E

S

T O

R M

IN

V

E L

.3

S T

A

.6

S

IT

E

S

A N

IT

A

R Y

IN

V

E L

.2

S T

A

.1

S

IT

E

S

T O

R M

IN

V

E L

.4

S T

A

.6

S

IT

E

W

A T

E R

IN

V

E L

.5

S tr u ct u re

S

T A

.3

R

IM

.1

IN

V

IN

S E

.7

IN

V

O

U T

N W

.7

S tr u ct u re

S

T A

.3

R

IM

.1

IN

V

IN

S E

.7

IN

V

O

U T

N W

.7

STA: 10+00.00

ELEV= 500.25

S T

A

.1

C D

B

IN

V E

L

.8

S T

A

.2

S

IT

E

W

A T

E R

IN

V

E L

.2

S T

A

.7

S

IT

E

W

A T

E R

IN

V

E L

.9

S T

A

.3

C D

B

IN

V E

L

.6

11.5"x20" PDB_

11.5"x20" PDB_

20"x11.5" PDB_

11.5"x2 0" P

DB_

S T

A

.9

E D

B

IN

V E

L

.3

P D

B

M H

S T

A

.2

R

IM

.6

IN

V

IN

N

W

.5

IN

V

O U

T S

E

.2

24" x 24" PDB_

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323395

S

IT

E E

L E

C T

R

IC

A L

P R

O F

IL

E

A. FOR ELECTRICAL GENERAL NOTES,

LEGEND, AND ABBREVIATIONS, SEE SHEET

14GI-E-001 THROUGH 14GI-E-007.

B. CONTRACTOR MUST VERIFY ELECTRICAL

CODE REQUIREMENTS AND

SPECIFICATIONS. CONTRACTOR MUST

COORDINATE WITH OTHER UTILITY

ROUTINGS.

GENERAL SHEET NOTES

8'4'0

40'20'0

VERTICAL

HORIZONTAL

10/04/24 10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

V A

T

IO

N I

N F

E E

T

STATION

PDB 40 STA 19+00 TO STA 23+50

19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50

1" = 20'A1 HORIZONTAL SCALE: 1" = 4'VERTICAL SCALE:

P D

B

M H

S T

A

.0

R

IM

.5

IN

V

IN

N

W

.7

IN

V

O U

T S

E

.9

P D

B

M H

S T

A

.0

R

IM

.7

IN

V

IN

N

W

.2

IN

V

O U

T S

W

.2

FINISHED GRADE

EXISTING GRADE

S

T A

.5

S

IT

E

W A

T E

R

IN

V E

L

.0

S T

A

.4

S

IT

E

S

T O

R M

IN

V

E L

.0

STA: 22+50.91

ELEV= 499.50

20"x11.5" PDB_

S T

A

.9

S

IT

E

W

A T

E R

IN

V

E L

.8

11.5"x20" PDB_

11.5"x20" PDB_

S T

A

.1

S

IT

E

S

A N

IT

A

R Y

IN

V

E L

.4

S T

A

.4

S

IT

E

W

A T

E R

IN

V

E L

.0

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323396

S

IT

E E

L E

C T

R

IC

A L

P R

O F

IL

E

A. FOR ELECTRICAL GENERAL NOTES,

LEGEND, AND ABBREVIATIONS, SEE SHEET

14GI-E-001 THROUGH 14GI-E-007.

B. CONTRACTOR MUST VERIFY ELECTRICAL

CODE REQUIREMENTS AND

SPECIFICATIONS. CONTRACTOR MUST

COORDINATE WITH OTHER UTILITY

ROUTINGS.

GENERAL SHEET NOTES

8'4'0

40'20'0

VERTICAL

HORIZONTAL

10/04/24 10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

LDB

LDB LDB LDB LDB LDB LDB LDB LDB LDB LDB

L D

B L

D B

L D

B L

D B

L D

B L

D B

LDBLDBLDB

L D

B L

D B

CDBCDB

CDB

CDB

CDB

CDB

CDB

CDBCDBCDBCDB

D B

L D

B L

D B

L D

B L

D B

L D

B L

D B

LDB

LDB

CDB

CDB

1+00

WWWWWWWWWW

W

W

S W

P

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323397

E N

L A

R G

E D

P

LA

N

F U

E L

U N

LO

A

D

IN

G

ENLARGED PLAN - FUEL UNLOADING

1" = 5'SCALE: A1 0 2.5 5

A. FOR ELECTRICAL GENERAL NOTES,

LEGEND, AND ABBREVIATIONS, SEE SHEET

14GI-E-001 THROUGH 14GI-E-007.

B. FOR GROUNDING DETAILS SEE SHEET

14ST-EG401.

C. FOR PANEL SCHEDULES SEE SHEET

14ST-ES701.

D. FOR ONE LINE DIAGRAM SEE SHEET

14ST-ES601.

E. LIGHT SWITCHES SHOWN WITHIN

ENCLOSURES ARE TO CONTROL FIXTURES

LOCALIZED TO ENCLOSURE.

F. SEE SHEET 14ST-EL501 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603

FOR LIGHTING CONTROL DIAGRAMS, AND

14ST-EL701 FOR LUMINAIRE SCHEDULE.

PANEL B03

TS106

PANEL C03

TS109

PANEL C02

TS108

PANEL B02

TS105

PANEL B01

TS104

PANEL C01

TS107

FUEL UNLOADING

POWER PANEL

PP-14UL61101

P1

PP-14UL61101:10

P1

PP-14UL61101:8

LC-14UL61101

SPD-14UL61101

FOP-14PP03107

FUEL PUMP

CONTROL PANEL

EHH-351

01 ROUTE ALL ABOVE GRADE CIRCUITS IN

RIGID ALUMINUM CONDUIT.

02 PROVIDE SINGLE WALL PENETRATION

TO PHOTOCELL. MOUNT PHOTOCELL AT

A HEIGHT SUITABLE FOR OPTIMAL LIGHT

SENSING AND UNOBSTRUCTED.

03 RECEPTACLE TO BE MOUNTED WITHIN

THE WEATHERPROOF PHONE

ENCLOSURE. REFER TO A1/14ST-TS512.

04 FIELD ROUTE 1" UNDERGROUND

CONDUIT TO AMI WATER METER

ENCLOSURE.

U14ST-2101

PP-14UL61101: 1,3,5

PHOTOCELL02

TX

PP-14UL61101:8

TX

PP-14UL61101:8

TX

PP-14UL61101:8

TX

PP-14UL61101:8

MPC-14UL61102:3

MPC-14UL61102:1

MPC-14UL61102

P1

PP-14UL61101:8

14GI-E-001

14GI-E-007

14ST-EL501

14ST-EL601 14ST-EL603

14ST-EL701

14ST-EG401

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

P D

B P

D B

P D

B

P D

B

PDB

PDB

PDB

LDB

LDB

LDB

PDB

LDB

LDB LDB LDB

XFMR-14ST61102

PP-14ST61102

LC-14ST61102

MDP-14ST61102

U14ST-4009

SWP TX

PP-14ST61102:16

TX

PP-14ST61102:16

TX

PP-14ST61102:16

TX

PP-14ST61102:16

PC-14ST61102

LDB

LD

B

LD

B

LD

B

EMH

P D

B P

D B

PDB PD

P D

B P

D B

P D

B

PDB

PDB

PDB

P D

B

P D

B

LC-14ST61101

PP-14ST61101

XFMR-14ST61101

EHH-14ST6003

14ST-4011

14ST-4002

S W

PTX

PP-14ST61101:22

PC-14ST61101

TX

PP-14ST61101:22

TX

PP-14ST61101:22

TX

PP-14ST61101:22

+0

E D

B E

D B

E D

B E

D B

EDBEDBEDBEDBEDB

E D

B

E D

B

PC-14ST61101

TX

LP-14PP61101A:13

SWP

TX

LP-14PP61101A:13

TX

LP-14PP61101A:13

TX

LP-14PP61101A:13

TX

LP-14PP61101A:13

SECT-14ST61101

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323398

E N

L A

R G

E D

P

LA

N

T R

A N

S F

O R

M E

R S

ENLARGED PLAN - XFMR-14ST61102

1" = 5'SCALE: A1 0 2.5 5

PANEL B03

TS106

PANEL C03

TS109

PANEL C02

TS108

PANEL B02

TS105

PANEL B01

TS104

PANEL C01

TS107

ENLARGED PLAN - XFMR-14ST61101

1" = 5'SCALE: C1

A. FOR ELECTRICAL GENERAL NOTES,

LEGEND, AND ABBREVIATIONS, SEE SHEET

14GI-E-001 THROUGH 14GI-E-007.

B. FOR GROUNDING DETAILS SEE SHEET

14ST-EG401.

C. FOR PANEL SCHEDULES SEE SHEET

14ST-ES701.

D. FOR ONE LINE DIAGRAM SEE SHEET

14ST-ES601.

E. FOR TRANSFORMER/CABINET DETAILS SEE

SHEET 14ST-EP521.

E. LIGHT SWITCHES SHOWN WITHIN

ENCLOSURES ARE TO CONTROL FIXTURES

LOCALIZED TO ENCLOSURE.

F. SEE SHEET 14ST-EL501 FOR LIGHTING

DETAILS, 14ST-EL601 THROUGH 14ST-EL603

FOR LIGHTING CONTROL DIAGRAMS, AND

14ST-EL701 FOR LUMINAIRE SCHEDULE.

01 ROUTE ALL ABOVE GRADE CIRCUITS IN

RIGID ALUMINUM CONDUIT.

02 PROVIDE SINGLE WALL PENETRATION

TO PHOTOCELL. MOUNT PHOTOCELL AT

A HEIGHT SUITABLE FOR OPTIMAL LIGHT

SENSING AND UNOBSTRUCTED.

ENLARGED PLAN - SECTIONALIZING CABINET

1" = 5'SCALE: A3

14GI-E-001

14GI-E-007

14ST-EP521

14ST-EL501

14ST-EL601 14ST-EL603

14ST-EL701

14ST-EG401

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

PDB_ STRUCTURES TABLE

NAME

PDB400HH01

PDB400MH01

PDB400MH02

PDB400MH04

PDB400MH05

STATION

13+68.82

13+88.56

16+71.73

20+06.03

21+43.03

NORTHING

680665.91

680681.29

680860.02

680650.07

680543.80

EASTING

392233.86

392221.48

392441.12

392682.81

392769.29

STRUCTURE DETAILS

RIM = 512.66

SUMP = ???

Pipe - (11) (1) (1) (1) INV IN = 510.19 (SE) 24" Pipe - (12) INV OUT = 511.05 (NW) 20"

RIM = 520.62

SUMP = 512.98

Pipe - (12) INV IN = 513.61 (SE) 20" Pipe - (13) INV OUT = 513.61 (NE) 20"

RIM = 519.06

SUMP = 511.27

Pipe - (13) (1) INV IN = 511.27 (SW) 20" Pipe - (14) INV OUT = 511.27 (SE) 20"

RIM = 508.56

SUMP = 501.56

Pipe - (38) INV IN = 504.74 (NW) 12" Pipe - (16) INV OUT = 504.96 (SE) 20"

RIM = 504.78

SUMP = 497.78

Pipe - (16) (1) (1) (1) INV IN = 499.23 (NW) 20" Pipe - (17) INV OUT = 499.23 (SW) 20"

EDB STRUCTURES TABLE

NAME

EDB200MH01

EDB201MH01

EDB300MH01

EDB301MH01

SECT-14ST61101

STATION

11+14.81

10+17.75

10+32.17

10+17.88

10+83.53

NORTHING

680404.36

680458.96

680352.67

680452.95

680377.72

EASTING

392460.39

392473.51

392495.86

392466.13

392475.68

STRUCTURE DETAILS

RIM = 508.77

SUMP = 501.25

Pipe - (1) INV IN = 501.27 (SE) 20" Pipe - (2) INV OUT = 501.25 (NE) 20"

RIM = 509.14

SUMP = 500.25

Pipe - (5) INV IN = 500.25 (SE) 20" Pipe - (6) INV OUT = 500.25 (NE) 20"

RIM = 507.33

SUMP = 500.33

Pipe - (3) INV IN = 501.04 (NW) 20" Pipe - (4) INV OUT = 501.00 (NE) 20"

RIM = 509.18

SUMP = 500.80

Pipe - (56) INV IN = 501.00 (SE) 20" Pipe - (57) INV IN = 501.28 (NW) 20"

RIM = 506.16

SUMP = 492.50

Pipe - (60) INV IN = 503.13 (NW) 20" Pipe - (3) INV OUT = 502.57 (SE) 20"

Pipe - (26) INV OUT = 503.13 (SW) 20"

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323399

E L

E C

T R

IC

A

L S

T R

U C

T U

R E

T A

B

LE

S

A. FOR ELECTRICAL GENERAL NOTES,

LEGEND, AND ABBREVIATIONS, SEE SHEET

14GI-E-001 THROUGH 14GI-E-006.

14GI-E-001

14GI-E-006

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

COMM

COMM

OMM

COMM

COMM

C O

M M

O M

M C

O M

M C

O M

M

W

W

W

W

W

W

W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W

WWWWWWWWWWWWWWW

W

W W

W W

W W

W W

W W

W W

W

W

W

W

W

W

W W W W WW

W

W

W

W

W

W

W

W

W

W W

W W

W W

W W

W W

W W

W W W W W W W W W W W W W W W

W

W

W

W W

W

W W

WWWWWWWWWWWWW

W

W W

W W

W W

W W

W W

W W

W

W

W

W

W

W

W W W

W

W

W

W

W

W

W

W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

E

E

E

E

E

E

E

E E

E E

E

E E

E E

E

E

E

E

E

E

E

E

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

EDB

E E

D B

EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB EDB

E

E E

E E

E E

E E

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

EIS

E

IS

E

IS

E

IS

EIS

EIS

EIS

EIS

EIS

E I

E

IS

EIS

EIS

EIS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

E

IS

EIS EIS EIS EIS EIS EIS EIS

LD

B

L D

B

LD

B L

D B

L D

B

LD

B

LD

B

LD

B L

D B

LDBLDBLDBLDBLDBLDB

LD

B

L D

B

LD

B

LD

B L

D B

LD

B

LDB LDB LDB LDB LDB LDB

LDBLDBLDBLDBLDB

L D

BLDBLDBLDBLDBLDBLDB

LDB

LD

B

LDB

LDB

P D

B

LD

B

EMH

EMH

EMHEMH

P D

B

EMH

EMH

EMH

EMH

TMH

TMH

TMH

CDB CDB CDB CDB CDB

TMH

TMH

TMH

EDB

L D

B

EMH

EMH

P D

B

C D

B C

D B

CDB CDB

CDB

CDB

C D

B C

D B

C D

B C

D B

C D

B C

D B

C D

B

PDBPDB

P D

B

P D

B P

D B

P D

B P

D B

PDB PDB

P D

B

PDBPDB

T

C D

B

LDBWW

W

W W

W

W

WW

W W

SS SS SS

S S

S S

S S

SS

W W

W

C O

M M

C O

M M

C O

M M

E x

E x

E x

E x

E x

E x

E x

E x

EDBx

E D

B E

D B

E D

B E

D B

E D

B E

D B

E D

B E

D B

E D

B

E D

B

EDB

EDB

EDB

EDB

EDB

EDB

EDB

X D

B X

D B

X D

B X

D B

X D

B X

D B

X D

B X

D B

XDBXDBXDB

X D

B X

D B

X D

B X

D B

X D

B

XDB XDB XDB XDB XDB XDB XDB XDB

X D

B

X D

B X

D B

X D

B X

D B

X D

B

XDBXDBXDBXDB

XDB

SWITCHGEAR

BUILDING

COMMAND CENTER

ACP

C B

C B

CB

D D

S D

S D

S D

S D

DD SDSDSD

S D

DCB SD

SD

SD

D

SDCB

SD

D

D

S D

S D

S D

S D

CB

CBD

S D

S D

S D

D

CB

SD

SD

CB

D

D

EAM

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

JC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 25 AUGUST 2020

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E CONTRACT NO. N62478-20-D-5036

A/E Task Order No. N6274223F0328

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

AS NOTED

ZAFSMMMCS

17323404

S

IT

E P

O W

E R

R A

C E

W A

Y O

V E

R A

L L

P L

A N

SITE POWER RACEWAY OVERALL PLAN

1" = 50'SCALE: A1 0 50 100

A. FOR ELECTRICAL GENERAL NOTES, LEGEND, AND

ABBREVIATIONS, SEE SHEET 14GI-E-001 THROUGH

14GI-E-007.

B. FOR ONE LINE DIAGRAM SEE SHEET 14ST-ES601

C. FOR UTILITY CONNECTION INTERFACE OUTSIDE OF

RESTRICTED FENCE, SEE 14ST-EU SERIES DRAWINGS

14GI-E-001

14GI-E-007

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263181

10/04/202410/04/2024

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263182

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263183

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263184

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263185

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263186

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263187

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263188

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263189

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263190

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263191

Approved By

CAPT Troy Brown, JRM J4 via email

9/24/2024

Approved By

CAPT Troy Brown, JRM J4

263192

Approved By

CAPT…