Am-0003 Attachment 1_Revised Drawings dtd 11-8-2024.pdf

PDF 5 MB Posted

Attached to
FY25 MCON P-693 PDI: GUAM DEFENSE SYSTEM, COMMAND CENTER, JOINT REGION MARIANAS, GUAM
Solicitation number
N6274225R1301
Issued by

About this file

This document appears to be a set of drawings and specifications related to a federal contract opportunity for the construction of a Guam Defense Radar System Command Center, power generation facility, and associated infrastructure at Andersen Air Force Base, Guam.

The key details include:

  • The project involves new construction of a command center, power plant, switchgear building, fuel storage facility, and entry control facility with an estimated value between $250-500 million.
  • The solicitation is being issued as an unrestricted, best-value trade-off source selection, with technical factors (experience, small business utilization, safety, management plan, past performance) and price being evaluated.
  • Relevant experience includes new construction of administrative/office/communications facilities over $80 million, secure space over $10 million, and essential facilities in moderate to high seismic areas over $80 million, all completed within the past 10 years.
  • The RFP will be available on 30 October 2024 and a pre-proposal site visit is scheduled for 11 December 2024.
  • The project has an anticipated completion period of 1,323 calendar days.

View the file

Other files

File Type Posted
25-1301 CmdCtrl Notice14.pdf PDF
Am-0011 Attachments 25-44.pdf PDF
Am-0011 Attachment 1_Revised Drawings dtd 1-28-2025.pdf PDF
Am-0011.pdf PDF
Am-0011 Attachments 2-24.pdf PDF
25-1301 CmdCtrl Notice13.pdf PDF
25-1301 CmdCtrl Notice12.pdf PDF
25-1301 CmdCtrl Notice11.pdf PDF
Am-0010 Attachment 2_Revised Drawings_Signed.pdf PDF
Am-0010.pdf PDF
25-1301 CmdCtrl Notice10.pdf PDF
25-1301 CmdCtrl Notice9.pdf PDF
Attachment 1_Revised Drawings_dtd 13 and 20 Dec 2024.pdf PDF
Am-0009.pdf PDF
Am-0008.pdf PDF
25-1301 CmdCtrl Notice8.pdf PDF
P693_Sign-in Sheets_Redacted.pdf PDF
Am-0007.pdf PDF
Am-0007 Attachment 1_Revised Drawings dtd 13 Dec 2024.pdf PDF
Am-0006 Attachment 1_Revised Drawings dtd 6 Dec 2024.pdf PDF
Am-0006.pdf PDF
25-1301 CmdCtrl Notice7.pdf PDF
Am-0005 Attachment 1_Revised Drawings dtd 11-22-2024.pdf PDF
Am-0005.pdf PDF
25-1301 CmdCtrl Notice6.pdf PDF
25-1301 CmdCtrl Notice5.pdf PDF
R-P693_Drawings_Final_Vol14.6_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.5_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.8_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.2_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.1_20241007.pdf PDF
25-1301 CmdCtrl Notice4.pdf PDF
R-P693_Drawings_Final_Vol14.7_20241007.pdf PDF
R-P693_Drawings_Final_Vol14.4_20241007.pdf PDF
Am-0004 Attachment 1_Revised Drawings dtd 11-15-2024.pdf PDF
25-1301 CmdCtr Notice3.pdf PDF
Am-0004.pdf PDF
Am-0003.pdf PDF
25-1301 CmdCtrl Notice2.pdf PDF
Am-0002.pdf PDF
Am-0001.pdf PDF
25-1301 CmdCtrl Notice1.pdf PDF
P693_Drawings_Final_Vol14.2_20241007-Part3.pdf PDF
P693_Drawings_Final_Vol14.1_20241007-Part3.pdf PDF
P693_Drawings_Final_Vol14.2_20241007-Part2.pdf PDF
P693_Drawings_Final_Vol14.7_20241007.pdf PDF
P693_Drawings_Final_Vol14.3_20241007.pdf PDF
25-1301 P-693 RFP.pdf PDF
P693_Specs_Final_Vol02_20241007.pdf PDF
P693_Drawings_Final_Vol14.6_20241007.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS SEE

SHEETS 14GI-M-001 THROUGH 14GI-M-008.

B. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS SEE

SHEETS 14CC-S-001 THROUGH 14CC-S-006 AND 14GI-S-010.

C. DISTRIBUTION SUPPORT ELEVATIONS ARE MEASURED FROM

"FIRST FLOOR" BASE LEVEL, UNLESS OTHERWISE NOTED.

D. DISTRIBUTION SUPPORT LOCATIONS IN (Y,X) ARE MEASURED OFF

OF CLOSEST INTERSECTION OF COLUMN GRIDLINES.

E. LOADS DISPLAYED ON PAGES 14CC-S-731 THROUGH 14CC-S-763

ARE FACTORED FOR ASCE 7-16 ASD LOAD COMBINATIONS.

F. FOR CLARITY, SUPPORT TAGS ON PLAN SHEETS ARE GENERALLY

ABBREVIATED. UNLESS OTHERWISE, THE SITE AND BUILDING

TAG (14CC) MUST BE ADDED TO COMPLETE EACH TAG.

G. CONTRACTOR TO DESIGN AND PROVIDE SUBFRAME FOR

DISTRIBUTION SUPPORTS IN ROOMS 130 AND 135. SEE 14CC-

S-794 FOR DETAILS.

H. SUPPORT STRUT AND ALL COMPONENTS MUST BE STAINLESS

STEEL FOR OUTSIDE AIR DUCT SUPPORTS. CONTACT OF

GALVANIZED AND STAINLESS STEEL COMPONENTS IS NOT

ALLOWED. SEE 14CC-S-714, 14CC-S-715 14CC-S-779, AND 14CC-

S-780 FOR APPLICABLE LOCATIONS.

DS-14CC31XXX

SUPPORT TYPE

SITE & BUILDING

SYSTEM CODE

TAG NUMBER

SYSTEM CODE

03 FUEL OIL SYSTEM

12 POTABLE WATER SYSTEM (PW, DCW, & DHW)

17 BUILDING WASTE SYSTEMS

(SANITARY, OIL WASTE, ROOF DRAINS, ETC.)

31 CHILLED WATER SYSTEMS

33 REFRIGERATION (DX) SYSTEMS

41 AIR SUPPLY, EXHAUST, AND VENTILATION SYSTEMS

52 FIRE PROTECTION SYSTEMS

1 2

C

A

B

1.5 2.3

C.3

B.7

B.3

DS-41009

DS-41008

DS-41039

DS-41038

DS-41040

DS-41042

DS-41044DS-41041

DS-41043

DS-41045

DS-41046 DS-41048

DS-41047

DS-41018

DS-41017

DS-41007

DS-41006

DS-41005

DS-41004

DS-41003

DS-41002

DS-41016

DS-41015

DS-41014

DS-41013

DS-41012

DS-41011

DS-41010

DS-41026

DS-41025

DS-41024

DS-41023

DS-41022

DS-41021

DS-41020

DS-41019

DS-41267

DS-41266

DS-41265

DS-41264

DS-41263

DS-41262

DS-41261

DS-41260

DS-41155

DS-41156

DS-41157

DS-41158

CI-41011

DS-41056

DS-41055

DS-41161

DS-41160

DS-41162

DS-41163 DS-41164

DS-41165

DS-41166

DS-41035

DS-41034

DS-41033

DS-41032

DS-41031

DS-41030

DS-41029

DS-41028

DS-41027

DS-41167

CI-41045

DS-41168

DS-41082

DS-41081

DS-41080

DS-41079

DS-41171

DS-41172

DS-41173

DS-41174

DS-41175

DS-41176

DS-41176A

DS-41177

DS-41178

DS-41085A

DS-41337

DS-41345

DS-41346

DS-41170

DS-41169

DS-41067

DS-41068

DS-41069

DS-41070

DS-41071 DS-41072 DS-41075

DS-41073

DS-41074

DS-41076

DS-41077

DS-41078

24"x24" SA

12"x12" EA

60"x30" SA

60"x30" RA

36"x40" RFA

36"x40" OA 92"x76" SA

16"x20" SA

28"ø SA

DS-41381

DS-41383

DS-41378

DS-41382

DS-41379

DS-41380

DS-41377

DS-41104

DS-41419

DS-41421

CI-41060

CI-41061

DS-41422

CI-41062

DS-41387

CI-41063

DS-41412

DS-41411

DS-41410

DS-41409

DS-41418

DS-41408

DS-41417

DS-41101

DS-41401

DS-41402

DS-41407

DS-41416

DS-41406DS-41405

DS-41415

DS-41404

DS-41413

DS-41414

DS-41403

54"x50" SA 48"x40" RA

DS-41053

DS-41051

DS-41054

DS-41052

DS-41159

CI-41012

DS-41001

DS-41440

DS-41439

DS-41438

DS-41433

DS-41434

DS-41435 DS-41436 DS-41437

DS-41419A

DS-41336

8"ø SA

DS-41066

DS-41063

DS-41064

DS-41065

CI-41065CI-41064

18"x18" SA 18"x18" RA

CI-41072

CI-41069

CI-41066

DS-41442

96"x96" RA

DS-41018A

DS-41026A

DS-41035A

DS-41267A

DIFFUSER SUPPORTED AT

WALL BY CONTRACTOR (TYP)

DS-41053A

DS-41381A

DS-41440A

DS-41441

DS-41381B

DS-41383A

DS-41085

DS-41037A

DS-41037

DS-41086

DS-41085B

DS-41418A

DS-41038A

DS-41450

DS-41451

10"ø EA

10"ø EA

SEE NOTE H

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

BC

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

AWK/DMK

KYM

/6 /2

:1 :4

P

M

C R e v it \l o c a l_

\P

C

C

M

S to

.r v t

14CC-S-714

C O

M M

A N

D C

E N

T E

R

F

IR

S T

F

LO

O R

H V

A C

D

IS

T R

IB

U

T

IO

N S

U P

P O

R T

P

LA

N A

R E

A

C

BJB

17323601

CJH THF

G U

A M

C C

-S -7

FINAL DESIGN SUBMITTAL

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

A B

DC

1/8" = 1'-0" 0 8' 16' 24'4'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

PLAN

NORTH

SHEET NAMING CONVENTION

SCALE: 1/8" = 1'-0"

A1

FIRST FLOOR HVAC SUPPORT PLAN - AREA C

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S

S D

U C

T S

U P

P O

R T

A D

D

N O

V E

M B

E R

ST

ATE OF ALASKA

CODY HARVEY

No. 195339

R

EG

ISTERED PROFESSIONA L E

NGIN

EE

R

49 TH

11/8/2024

11/14/2024

B. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS SEE

SHEETS 14CC-S-001 THROUGH 14CC-S-006 AND 14GI-S-010.

C. DISTRIBUTION SUPPORT ELEVATIONS ARE MEASURED FROM

"FIRST FLOOR" BASE LEVEL, UNLESS OTHERWISE NOTED.

D. DISTRIBUTION SUPPORT LOCATIONS IN (Y,X) ARE MEASURED OFF

OF CLOSEST INTERSECTION OF COLUMN GRIDLINES.

E. LOADS DISPLAYED ON PAGES 14CC-S-731 THROUGH 14CC-S-763

ARE FACTORED FOR ASCE 7-16 ASD LOAD COMBINATIONS.

F. FOR CLARITY, SUPPORT TAGS ON PLAN SHEETS ARE GENERALLY

ABBREVIATED. UNLESS OTHERWISE, THE SITE AND BUILDING

TAG (14CC) MUST BE ADDED TO COMPLETE EACH TAG.

G. CONTRACTOR TO DESIGN AND PROVIDE SUBFRAME FOR

DISTRIBUTION SUPPORTS IN ROOMS 130 AND 135. SEE 14CC-

S-794 FOR DETAILS.

H. SUPPORT STRUT AND ALL COMPONENTS MUST BE STAINLESS

STEEL FOR OUTSIDE AIR DUCT SUPPORTS. CONTACT OF

GALVANIZED AND STAINLESS STEEL COMPONENTS IS NOT

ALLOWED. SEE 14CC-S-714, 14CC-S-715 14CC-S-779, AND 14CC-

S-780 FOR APPLICABLE LOCATIONS.

DS-14CC31XXX

SUPPORT TYPE

SITE & BUILDING

SYSTEM CODE

TAG NUMBER

SYSTEM CODE

03 FUEL OIL SYSTEM

12 POTABLE WATER SYSTEM (PW, DCW, & DHW)

17 BUILDING WASTE SYSTEMS

(SANITARY, OIL WASTE, ROOF DRAINS, ETC.)

31 CHILLED WATER SYSTEMS

33 REFRIGERATION (DX) SYSTEMS

41 AIR SUPPLY, EXHAUST, AND VENTILATION SYSTEMS

52 FIRE PROTECTION SYSTEMS

3 4

C

A

B

2.7 3.3 3.7

C.3

B.7

B.3

DS-41250

DS-41251

DS-41200

DS-41199

CI-41021

CI-41020

DS-41197

DS-41193

DS-41194

DS-41195

DS-41196

CI-41018

CI-41017

DS-41192

DS-41365

DS-41364

DS-41363

DS-41362

DS-41361

DS-41360DS-41359DS-41358DS-41357DS-41356

DS-41355

DS-41259

DS-41258

DS-41257

DS-41256

DS-41255

DS-41254 DS-41253

DS-41252

DS-41086

DS-41087

DS-41088

DS-41089

DS-41090

CI-41019

DS-41338

DS-41339

DS-41347

DS-41340

DS-41348

DS-41179

DS-41180

CI-41015

DS-41341

DS-41342

DS-41344

DS-41343

DS-41351

DS-41344A

DS-41181

DS-41182

DS-41183

DS-41184

DS-41352

DS-41185

DS-41188

DS-41189

DS-41190

DS-41179A

DS-41182A

DS-41349

DS-41350

DS-41191

36"x40" RFA

36"x40" OA

10"ø SA

10"ø SA

14"ø SA

28"x20" SA

DS-41091

CI-41039

CI-41046

10"ø SA

60"ø RA

CI-41043

DS-41354

DS-41376

DS-41198

DS-41249

CI-41022

CI-41042

CI-41041

CI-41013

CI-41014

CI-41016

CI-41059

DS-41105

16"x16" SA

36"x40" OA

40"x36" RFA

8"ø SA

DS-41353A

DS-41432

DS-41431

DS-41430

DS-41388

DS-41036

DS-41420

36"x36" EA

DS-41443

CI-41067

CI-41074

CI-41071

CI-41068

DS-41444

CI-41073

DS-41432A

DIFFUSER SUPPORTED AT

WALL BY CONTRACTOR (TYP)

CI-41082

DS-41090A

DS-41088A

DS-41090B

DS-41178A

DS-41180A

DS-41184A

DS-41186A

DS-41187A

DS-41188A DS-41189A

DS-41186

DS-41187

DS-41191A

SEE NOTE H SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

BC

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

AWK/DMK

KYM

/6 /2

:1 :4

P

M

C R e v it \l o c a l_

\P

C

C

M

S to

.r v t

14CC-S-715

C O

M M

A N

D C

E N

T E

R

F

IR

S T

F

LO

O R

H V

A C

D

IS

T R

IB

U

T

IO

N S

U P

P O

R T

P

LA

N A

R E

A

D

BJB

17323602

CJH THF

G U

A M

C C

-S -7

FINAL DESIGN SUBMITTAL

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

A B

DC

1/8" = 1'-0" 0 8' 16' 24'4'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

PLAN

NORTH

SHEET NAMING CONVENTION

SCALE: 1/8" = 1'-0"

A1

FIRST FLOOR HVAC SUPPORT PLAN - AREA D

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S

S D

U C

T S

U P

P O

R T

A D

D

N O

V E

M B

E R

ST

ATE OF ALASKA

CODY HARVEY

No. 195339

R

EG

ISTERED PROFESSIONA L E

NGIN

EE

R

49 TH

B

C

A

1.5 2.3

C.3

B.7

B.3

DF-43T

DF-43T

DF-13T

DF-13TDF-34

DF-34

DF-12L

DF-12LDF-01 DF-01

DF-01

DF-45TL

DF-45T

DF-45T

DF-45T

DF-45T

DF-34DF-34

DF-34DF-34

DF-34

DF-34

DF-34

DF-34

DF-34

DF-34

DF-34

DF-34

DF-34

DF-34

DF-01

DF-01 DF-12T DF-01

DF-12T DF-12T

DF-01

DF-01

DF-12T

DF-01

DF-01

DF-01

DF-12T

DF-12T

DF-01

DF-01

DF-01

DF-12T

DF-01

DF-01

DF-01

DF-37T

DF-37T

DF-37T

DF-37TL

DF-43T

DF-43T

DF-43T

DF-43T

DF-43T

DF-43T

DF-43T

DF-34

DF-34

DF-34

DF-12T

DF-01

DF-01

DF-01

DF-01

DF-01

DF-12T

DF-12T

DF-12T

DF-12T

DF-12T

DF-01

DF-01

DF-01

DF-12T

DF-01

DF-01

DF-01

DF-13T

DF-01

DF-02

DF-12T DF-12L

DF-02

DF-12T

DF-01

DF-02

DF-37T

DF-48

DF-48

DF-12T

DF-12T

DF-12T

DF-37T

DF-37T

DF-37T

DF-12T

DF-12T

DF-12T

DF-48

DF-01

DF-34

DF-34

DF-34

DF-34DF-34

?DF-34DF-34DF-34DF-34DF-34

DF-48

DF-37T

DF-37T

DF-37T

DF-45T

DF-50DF-50DF-50DF-50DF-50DF-50

DF-21T DF-07 DF-21T

DF-13T

DF-07 DF-07 DF-43T

DF-43T

DF-43T

DF-43L

DF-37T

DF-12T

DF-12T

DF-12T

DF-12T

DF-12T

DF-12T

DF-12T

DF-01

DF-12T

DF-53T

DF-01

DF-12T

DF-34

DF-34

DF-08

DF-26T

DF-08

DF-26TL

DF-08

DF-26T

DF-08

DF-08

DF-34

DF-34

DF-08

DF-08

DF-12T

DF-12T

DF-01

DF-12T

DF-01

M A

T C

H

LI

N E

A

C C

-S -7

80MATCHLINE

A1 / 14CC-S-777

DF-34 DF-34

DF-34

DF-34

DF-08

DF-34

DF-34DF-34DF-34

DF-34

DF-34DF-34DF-34DF-34

DF-34

DF-01

DF-01

DF-01

DF-53T

DF-53T

DF-12T

DF-12T

DF-07

DF-07

DF-07

DF-57

DF-55

DF-55

SEE

NOTE Q

DF-XX[T][L][TL]

SUPPORT FRAME

DETAIL NUMBER

TRANSVERSE BRACE

LONGITUDINAL BRACE

TRANS & LONG BRACE

A. FOR STRUCTURAL GENERAL NOTES AND ABBREVIATIONS, SEE

SHEETS 14CC-S-001 THROUGH 14CC-S-006 AND 14GI-S-010.

B. FOR STRUT CONNECTION DETAILS, SEE DRAWINGS 14CC-S-795 AND

14CC-S-796. FOR MEP SUPPORT ATTACHMENT POINT DETAILS

(AP), SEE DRAWINGS 14CC-S-797 THROUGH 14CC-S-798.

C. ITEM DESCRIPTIONS AND REQUIRED CAPACITIES ARE INDICATED ON

14CC-S-799.

D. HORIZONTAL STRUT WIDTHS MUST BE USED TO DETERMINE STRUT

SIZE IN "TABLE 1" ON 14CC-S-799.

E. WHERE CAPACITY OF HORIZONTAL STRUT 100 IS EXCEEDED, USE

STRUT 101 UNLESS NOTED OTHERWISE NOTED. SEE SCHEDULES ON

14CC-S-731 THROUGH 14CC-S-763 FOR LOADING AT SUPPORTS.

F. BRACE LENGTH IS MEASURED FROM HINGE TO ATTACHMENT POINT

(AP), AND MUST BE USED TO DETERMINE STRUT SIZE IN "TABLE 2" ON

14CC-S-799.

G. HANGER ROD STIFFENERS ARE REQUIRED WHEN THE UNBRACED

ROD LENGTH EXCEEDS 24 INCHES AND AT ALL LOCATIONS WHERE A

BRACING STRUT IS USED. THE REQUIRED STIFFENER CLIP SPACING

MUST BE PER "TABLE 3" ON 14CC-S-799.

H. THE REQUIRED SEISMIC HINGED FITTING CAPACITIES MUST BE PER

"TABLE 4" ON 14CC-S-799.

J. IF PLAN INDICATES THAT SUPPORT STRUT EXTENDS TO A WALL, THE

MAXIMUM DISTANCE OF 6" FROM HANGER ROD TO EDGE OF

DUCT/TRAY/PIPE MAY BE EXCEEDED.

K. DISTRIBUTION SUPPORTS MUST BE SPACED AS SHOWN ON PLAN

DRAWINGS 14CC-S-766 THROUGH 14CC-S-781. MAXIMUM SPACING OF

SUPPORTS MUST BE 9', UNLESS NOTED OTHERWISE ON DRAWINGS.

L. DISTRIBUTION FRAMES FOLLOW THE BELOW NAMING CONVENTION.

WHERE "T" OR "L" OR "TL" IS IN FRAME CALLOUT ON PLAN SHEETS

14CC-S-766 THROUGH 14CC-S-781, A TRANSVERSE AND/OR

LONGITUDINAL BRACE IS REQUIRED.

M. CONTRACTOR TO DESIGN AND PROVIDE SUBFRAME FOR

DISTRIBUTION SUPPORTS IN ROOMS 130 AND 135. SEE 14CC-S-794

FOR DETAILS.

N. THE REQUIRED CANTILIEVER SUPPORT STRUT CAPACITIES MUST BE

PER "TABLE 6" ON 14CC-S-799.

O. DUCT SUPPORTS USING ITEM 102 MUST ALSO USE AP-02 ON SHEET

14CC-S-797 AND DETAIL C2 ON SHEET 14CC-S-795.

P. SUPPORT STRUT FRAMES WHERE BOTH TRANSVERSE AND

LONGITUDINAL BRACES ARE USED, TRANSVERSE BRACES MUST BE

CONNECTED TO THE SUPPORT STRUT PER DETAIL A2 ON 14CC-

S-795 AND LONGITUDINAL BRACES MUST BE CONNECTED

THROUGH THE HANGER ROD PER DETAIL A1 ON 14CC-S-796.

Q. SUPPORT STRUT AND ALL COMPONENTS MUST BE STAINLESS STEEL

FOR OUTSIDE AIR DUCT SUPPORTS. CONTACT OF GALVANIZED AND

STAINLESS STEEL COMPONENTS IS NOT ALLOWED. SEE 14CC-S-714,

14CC-S-715, 14CC-S-779, AND 14CC-S-780 FOR APPLICABLE

LOCATIONS.

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

A B

DC

3/32" = 1'-0" 0 8' 16' 32'4'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

PLAN

NORTH

SHEET NAMING CONVENTION

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

BC

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

AWK/DMK

KYM

/6 /2

:0 :2

P

M

C R e v it \l o c a l_

\P

C C

A

S

S to

.r v t

14CC-S-779

C O

M M

A N

D C

E N

T E

R

F

IR

S T

F

LO

O R

S

U P

P O

R T

F R

A M

IN

G

P

LA

N A

R E

A C

LHT

17323660

CJH JMS

G U

A M

C C

-S -7

FINAL DESIGN SUBMITTAL

SCALE: 3/32" = 1'-0"

A1

FIRST FLOOR - SUPPORT FRAMING PLAN AREA C

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S

S D

U C

T S

U P

P O

R T

A D

D

N O

V E

M B

E R

ST

ATE OF ALASKA

CODY HARVEY

No. 195339

R

EG

ISTERED PROFESSIONA L E

NGIN

EE

R

49 TH

B

3 4

C

A

2.7 3.3 3.7

C.3

B.7

B.3

DF-43L

DF-43T DF-43T

DF-43T

DF-34

DF-30T

DF-28

DF-28

DF-28 DF-28L

DF-29

DF-28

DF-28

DF-28L

DF-12T

DF-01

DF-37T DF-01

DF-12T

DF-12L

DF-12T

DF-01

DF-37T

DF-37T

DF-37TL

DF-37T

DF-02

DF-12T

DF-12T

DF-01

DF-01

DF-01

DF-12T

DF-28

DF-28

DF-43T

DF-43T

DF-43T

DF-12T

DF-12T

DF-01DF-12L DF-12T DF-01 DF-01 DF-12T DF-01

DF-12T

DF-12T

DF-01

DF-12T

DF-01

DF-12T

DF-01

DF-12T

DF-01

DF-01

DF-54T

DF-08

DF-54T

DF-54TDF-08

DF-08

DF-26TL

DF-08

DF-28 DF-28 DF-28 DF-28 DF-28 DF-28 DF-28 DF-28

DF-12T

DF-37T

DF-01DF-14TDF-14TDF-03DF-14TDF-14T

DF-03

DF-03

DF-03

DF-14T DF-14T

DF-26T

DF-08

DF-08

DF-12T

DF-54T

DF-54T

DF-34

DF-28DF-08

DF-34

DF-34

DF-26T

SEE NOTE M

DF-12T

DF-03

DF-14T

DF-03DF-14T

DF-01

DF-12T

DF-01

DF-12T

DF-12T

DF-12T DF-12T

MATCHLINE

A1 / 14CC-S-778

M A

T C

H

LI

N E

A

C C

-S -7

DF-28

DF-12T

DF-54T

DF-01DF-12T

DF-12L

DF-12T

DF-01

DF-01

DF-54T

DF-54T

DF-12T

DF-14T

DF-01

SEE 14CC-TX506 FOR

EXTERIOR LADDER

TRAY DETAILS

SEE

NOTE Q

DF-XX[T][L][TL]

SUPPORT FRAME

DETAIL NUMBER

TRANSVERSE BRACE

LONGITUDINAL BRACE

TRANS & LONG BRACE

A. FOR STRUCTURAL GENERAL NOTES AND ABBREVIATIONS, SEE

SHEETS 14CC-S-001 THROUGH 14CC-S-006 AND 14GI-S-010.

B. FOR STRUT CONNECTION DETAILS, SEE DRAWINGS 14CC-S-795 AND

14CC-S-796. FOR MEP SUPPORT ATTACHMENT POINT DETAILS

(AP), SEE DRAWINGS 14CC-S-797 THROUGH 14CC-S-798.

C. ITEM DESCRIPTIONS AND REQUIRED CAPACITIES ARE INDICATED ON

14CC-S-799.

D. HORIZONTAL STRUT WIDTHS MUST BE USED TO DETERMINE STRUT

SIZE IN "TABLE 1" ON 14CC-S-799.

E. WHERE CAPACITY OF HORIZONTAL STRUT 100 IS EXCEEDED, USE

STRUT 101 UNLESS NOTED OTHERWISE NOTED. SEE SCHEDULES ON

14CC-S-731 THROUGH 14CC-S-763 FOR LOADING AT SUPPORTS.

F. BRACE LENGTH IS MEASURED FROM HINGE TO ATTACHMENT POINT

(AP), AND MUST BE USED TO DETERMINE STRUT SIZE IN "TABLE 2" ON

14CC-S-799.

G. HANGER ROD STIFFENERS ARE REQUIRED WHEN THE UNBRACED

ROD LENGTH EXCEEDS 24 INCHES AND AT ALL LOCATIONS WHERE A

BRACING STRUT IS USED. THE REQUIRED STIFFENER CLIP SPACING

MUST BE PER "TABLE 3" ON 14CC-S-799.

H. THE REQUIRED SEISMIC HINGED FITTING CAPACITIES MUST BE PER

"TABLE 4" ON 14CC-S-799.

J. IF PLAN INDICATES THAT SUPPORT STRUT EXTENDS TO A WALL, THE

MAXIMUM DISTANCE OF 6" FROM HANGER ROD TO EDGE OF

DUCT/TRAY/PIPE MAY BE EXCEEDED.

K. DISTRIBUTION SUPPORTS MUST BE SPACED AS SHOWN ON PLAN

DRAWINGS 14CC-S-766 THROUGH 14CC-S-781. MAXIMUM SPACING OF

SUPPORTS MUST BE 9', UNLESS NOTED OTHERWISE ON DRAWINGS.

L. DISTRIBUTION FRAMES FOLLOW THE BELOW NAMING CONVENTION.

WHERE "T" OR "L" OR "TL" IS IN FRAME CALLOUT ON PLAN SHEETS

14CC-S-766 THROUGH 14CC-S-781, A TRANSVERSE AND/OR

LONGITUDINAL BRACE IS REQUIRED.

M. CONTRACTOR TO DESIGN AND PROVIDE SUBFRAME FOR

DISTRIBUTION SUPPORTS IN ROOMS 130 AND 135. SEE 14CC-S-794

FOR DETAILS.

N. THE REQUIRED CANTILIEVER SUPPORT STRUT CAPACITIES MUST BE

PER "TABLE 6" ON 14CC-S-799.

O. DUCT SUPPORTS USING ITEM 102 MUST ALSO USE AP-02 ON SHEET

14CC-S-797 AND DETAIL C2 ON SHEET 14CC-S-795.

P. SUPPORT STRUT FRAMES WHERE BOTH TRANSVERSE AND

LONGITUDINAL BRACES ARE USED, TRANSVERSE BRACES MUST BE

CONNECTED TO THE SUPPORT STRUT PER DETAIL A2 ON 14CC-

S-795 AND LONGITUDINAL BRACES MUST BE CONNECTED

THROUGH THE HANGER ROD PER DETAIL A1 ON 14CC-S-796.

Q. SUPPORT STRUT AND ALL COMPONENTS MUST BE STAINLESS STEEL

FOR OUTSIDE AIR DUCT SUPPORTS. CONTACT OF GALVANIZED AND

STAINLESS STEEL COMPONENTS IS NOT ALLOWED. SEE 14CC-S-714,

14CC-S-715, 14CC-S-779, AND 14CC-S-780 FOR APPLICABLE

LOCATIONS.

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

A B

DC

3/32" = 1'-0" 0 8' 16' 32'4'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

PLAN

NORTH

SHEET NAMING CONVENTION

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

BC

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

AWK/DMK

KYM

/6 /2

:0 :2

P

M

C R e v it \l o c a l_

\P

C C

A

S

S to

.r v t

14CC-S-780

C O

M M

A N

D C

E N

T E

R

F

IR

S T

F

LO

O R

S

U P

P O

R T

F R

A M

IN

G

P

LA

N A

R E

A D

LHT

17323661

CJH JMS

G U

A M

C C

-S -7

FINAL DESIGN SUBMITTAL

SCALE: 3/32" = 1'-0"

A1

FIRST FLOOR - SUPPORT FRAMING PLAN AREA D

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

S

S D

U C

T S

U P

P O

R T

A D

D

N O

V E

M B

E R

ST

ATE OF ALASKA

CODY HARVEY

No. 195339

R

EG

ISTERED PROFESSIONA L E

NGIN

EE

R

49 TH

E

C1

14CC-A-301

D

M A

T C

H

LI

N E

A

C C

-A -1

MATCHLINE

A1 / 14CC-A-114

155A

152A

154A 153A

115A

122A

121 122

124A

110A

7'-0 5/8" 32'-1 5/8"

S4

46'-5 1/4"

S4

S4 S4

V1

S4

K1K1

K2

6'-3 1/2"

123A

109A

120A

19'-11 3/8" 11'-10 1/2" 11'-10 1/2"

F5

F5F5 F5

S5

F6

K1

S4

S4

F5 F5

K1 K2

F7

F7

F7

F5 F5F5

4' -2

/4

'-5

/4

4' -2

/4

'-3

1'-9 1/4"

1'-9 1/4"

1'-9 1/4"

S4

S4

S4

F9

A5

A5

S5

1' -4

8"

29'-0" 16'-7 1/2"

111A

S5S5

158A

114A

S5

3' -9

/8

121A

S4

S4

119A

S4

6' -4

/8

'-1

/8

116A

113A

'-1

1/

2"

11'-10 1/2"

14'-2 1/2"

125A

111B

148B

S4

A3

A3

A3

A3

S4

S4

12'-10 1/2" 12'-10 1/2" 10'-10 1/2"16'-4 5/8" 6'-2 1/2" 8'

-7

/8

'-5

/8

14CC-A-402

A1

14CC-A-430

C1

14CC-A-434

A2

SF-112

120A

120B120C

1" / 12"

2'-6 5/8" 3'-3 7/8"

10'-7"

'-2

/2

6'

-2

/4

'-1

3/

4" 8"

A3

A3

S4 A3

S5

S5

S5

S5

S4

S4

120B

A4

8"

8"

8"

8"

A3

14CC-A-411

A2

151A

1'-0" 19'-2"

F6

S3

'-8

/4

F5

K2

A. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS, REFER TO SHEET

14GI-A-001.

B. FOR ALL WALL TYPES, REFER TO SHEET 14CC-A-501 AND 14CC-A-502.

C. FOR INTERIOR FINISHES, REFER TO SHEET 14CC-A-601.

D. DIMENSIONS INDICATED FOR NEW WORK ARE TO FACE OF STUD, FACE

OF PRECAST CONCRETE OR FACE OF EXISTING SURFACES UNLESS

OTHERWISE NOTED.

E. MAINTAIN A MINIMUM CLEAR WIDTH IN THE UNOBSTRUCTED PATH OF 3

FEET.

F. REFER TO STRUCTURAL DRAWINGS FOR PRECAST OPENING LOCATIONS.

SPECIAL USE SPACE BOUNDARY

PRECAST CONCRETE WALL,

REF. STRUCTURAL

NEW METAL STUD WALL,

REF. 14CC-A-501

01. PRECAST PANEL OPENING FOR EQUIPMENT MOVEMENT. REFER TO

STRUCTURAL. INFILL WITH 2-HR RATED WALL ASSEMBLY AFTER ALL

EQUIPMENT HAS BEEN INSTALLED IN ROOM 107.

02. PRECAST PANEL COVERED ENTRANCE, REFER TO STRUCTURAL.

03. CAST-IN-PLACE CONCRETE CANTILEVER STRUCTURAL SLAB EDGE WITH

FLUID APPLIED ELASTOMERIC COATING, REFER TO STRUCTURAL

04. AREA OF REFUGE.

05. OPERABLE PARTITION.

06. CABLE RAILING SYSTEM

07. STAINLESS STEEL DOWNSPOUT WITH STRAPS SPACED AT 5'-0" O.C.

DOWNSPOUT TO BE LOCATED AT PRE-CAST WALL JOINT/PILASTER.

REFER TO SHEETS 14CC-A-521 & 14CC-A-522 FOR DOWNSPOUT SIZING.

08. REMOVABLE RAIL FOR EQUIPMENT ACCESS.

09. SCUPPER / DOWNSPOUT

10. CONCRETE RAMPS BELOW FINISH FLOOR, REFER TO STRUCTURAL

11. ELEVATED CONC INFILL SLAB UNDER RAF, REFER TO STRUCTURAL

12. ANTENNA TOWER CONC SLAB, REFER TO STRUCTURAL

13. VENTED FLOOR TILES, REFER TO MECHANICAL

14. ELEVATED TOPPING CRICKET, REFER TO STRUCTURAL DRAWINGS FOR

SLOPE INFORMATION.

15. SCUPPER OPENING IN CURB WALL. REFER TO STRUCTURAL

SHEET 14CC-S-121 FOR SIZES AND LOCATIONS.

16. VERIFY DIMENSION WITH PARTITION MANUFACTURER.

17. STEEL COLUMNS FOR KNOWLEDGE WALL SUPPORT TO BE ENGINEERED,

SUPPLIED AND INSTALLED BY KNOWLEDGE WALL VENDOR.

18. STAINLESS STEEL LOUVERED FEBR RATED SCREEN WALL. REFER TO

STRUCTURAL.

19. STAINLESS STEEL ROOF ACCESS STAIR WITH STAINLESS STEEL BAR

GRATING ON TREADS AND LANDING. REFER TO STRUCTURAL.

20. DOOR FOR PRELIMINARY AND FUTURE EQUIPMENT INSTALLATION,

NOT FOR EGRESS.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

KYM

AWK/DMK

KYM

/6 /2

:1 :4

P

M

C R e v it \l o c a l_

\P

C C

A

S e d m o n d s m

.r v t

14CC-A-112

C O

M M

A N

D C

E N

T E

R

F

IR

S T

F

LO

O R

P

LA

N

A R

E A

A

CMA

17323727

JLG MDE

G U

A M

C C

-A -1

FINAL DESIGN SUBMITTAL

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

A B

DC

1/8" = 1'-0" 0 8' 16' 24'4'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

SHEET KEYNOTES

LEGEND

PLAN

NORTH

SHEET NAMING CONVENTION

SCALE: 1/8" = 1'-0"

A1

FIRST FLOOR PLAN - AREA A

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

W

A

LL

T Y

P E

K

A D

D

N O

V E

M B

E R

11.08.2024

UP UP

DN

DN

DN

DN

UP

B

C

147B

MATCHLINE

A1 / 14CC-A-112

M A

T C

H

LI

N E

A

C C

-A -1

148A

142A

142B

A

146 145 144 143 137

146A 143A

137A

146B 145B 144B 143B

141 140

1'-4"

'-3

1'

-3

'-8

/8

8'

-9

/8

1' -4

K1

F5

F5

S4

A3

S5

K2

A5A5

K1

B9 A3 B9 B9

17'-7 1/4" 27'-6 1/2" 27'-6 1/2" 18'-2 3/8"

8"

/2

F7 S4

F5 F5

144A145A

R5

R5

S5S5

R5

ALIGN

147A

14CC-A-432

A1

14CC-A-433

A2

14CC-A-433

A1

F9

159A

B9B9 A3

F5 F5

137B 137C

1'-4" 1'-8" 42'-9 1/4"

150A

14CC-A-437

B1

14CC-A-411

A2

158A 148B

A4

5' -7

4'

-3

/8

8" 7'-0 5/8"

B6

A. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS, REFER TO SHEET

14GI-A-001.

B. FOR ALL WALL TYPES, REFER TO SHEET 14CC-A-501 AND 14CC-A-502.

C. FOR INTERIOR FINISHES, REFER TO SHEET 14CC-A-601.

D. DIMENSIONS INDICATED FOR NEW WORK ARE TO FACE OF STUD, FACE

OF PRECAST CONCRETE OR FACE OF EXISTING SURFACES UNLESS

OTHERWISE NOTED.

E. MAINTAIN A MINIMUM CLEAR WIDTH IN THE UNOBSTRUCTED PATH OF 3

FEET.

F. REFER TO STRUCTURAL DRAWINGS FOR PRECAST OPENING LOCATIONS.

SPECIAL USE SPACE BOUNDARY

PRECAST CONCRETE WALL,

REF. STRUCTURAL

NEW METAL STUD WALL,

REF. 14CC-A-501

01. PRECAST PANEL OPENING FOR EQUIPMENT MOVEMENT. REFER TO

STRUCTURAL. INFILL WITH 2-HR RATED WALL ASSEMBLY AFTER ALL

EQUIPMENT HAS BEEN INSTALLED IN ROOM 107.

02. PRECAST PANEL COVERED ENTRANCE, REFER TO STRUCTURAL.

03. CAST-IN-PLACE CONCRETE CANTILEVER STRUCTURAL SLAB EDGE WITH

FLUID APPLIED ELASTOMERIC COATING, REFER TO STRUCTURAL

04. AREA OF REFUGE.

05. OPERABLE PARTITION.

06. CABLE RAILING SYSTEM

07. STAINLESS STEEL DOWNSPOUT WITH STRAPS SPACED AT 5'-0" O.C.

DOWNSPOUT TO BE LOCATED AT PRE-CAST WALL JOINT/PILASTER.

REFER TO SHEETS 14CC-A-521 & 14CC-A-522 FOR DOWNSPOUT SIZING.

08. REMOVABLE RAIL FOR EQUIPMENT ACCESS.

09. SCUPPER / DOWNSPOUT

10. CONCRETE RAMPS BELOW FINISH FLOOR, REFER TO STRUCTURAL

11. ELEVATED CONC INFILL SLAB UNDER RAF, REFER TO STRUCTURAL

12. ANTENNA TOWER CONC SLAB, REFER TO STRUCTURAL

13. VENTED FLOOR TILES, REFER TO MECHANICAL

14. ELEVATED TOPPING CRICKET, REFER TO STRUCTURAL DRAWINGS FOR

SLOPE INFORMATION.

15. SCUPPER OPENING IN CURB WALL. REFER TO STRUCTURAL

SHEET 14CC-S-121 FOR SIZES AND LOCATIONS.

16. VERIFY DIMENSION WITH PARTITION MANUFACTURER.

17. STEEL COLUMNS FOR KNOWLEDGE WALL SUPPORT TO BE ENGINEERED,

SUPPLIED AND INSTALLED BY KNOWLEDGE WALL VENDOR.

18. STAINLESS STEEL LOUVERED FEBR RATED SCREEN WALL. REFER TO

STRUCTURAL.

19. STAINLESS STEEL ROOF ACCESS STAIR WITH STAINLESS STEEL BAR

GRATING ON TREADS AND LANDING. REFER TO STRUCTURAL.

20. DOOR FOR PRELIMINARY AND FUTURE EQUIPMENT INSTALLATION,

NOT FOR EGRESS.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

KYM

AWK/DMK

KYM

/6 /2

:1 :4

P

M

C R e v it \l o c a l_

\P

C C

A

S e d m o n d s m

.r v t

14CC-A-114

C O

M M

A N

D C

E N

T E

R

F

IR

S T

F

LO

O R

P

LA

N

A R

E A

C

CMA

17323729

JLG MDE

G U

A M

C C

-A -1

FINAL DESIGN SUBMITTAL

SCALE: 1/8" = 1'-0"

A1

FIRST FLOOR PLAN - AREA C

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

A B

DC

1/8" = 1'-0" 0 8' 16' 24'4'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

SHEET KEYNOTES

LEGEND

PLAN

NORTH

SHEET NAMING CONVENTION

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

W

A

LL

T Y

P E

K

A D

D

N O

V E

M B

E R

FIRST FLOOR

100'-0"

TOC EL

86'-10"

TOC FIRST FLOOR

COMPOSITE SLAB

98'-0"

2 1.5

A1

14CC-A-303

14CC-A-542

B3

14CC-A-521

A3 OH

154153

153A 154A

07 05

09TYP

14CC-A-528

C1

14CC-A-521

A3

14CC-A-541

B2

14CC-A-531

A2

A. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS, REFER TO

SHEET 14GI-A-001.

B. ARCHITECTURAL FINISH FLOOR PLAN ELEVATION (100'-0"). INDICATES

THE TOP OF THE FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR ACTUAL

SITE REFERENCE ELEVATION.

C. SPECIAL USE SPACE BOUNDARY WALLS MUST BE PAINTED FROM

SPECIAL USE SPACE BOUNDARY FLOOR TO SPECIAL USE SPACE

BOUNDARY CEILING OR DECK, COLOR AS SPECIFIED. GYPSUM

BOARD SPECIAL USE SPACE BOUNDARY WALLS MUST BE FINISHED AS

SPECIFIED IN SPECIFICATION 09 29 00 FROM SPECIAL USE SPACE

BOUNDARY FLOOR TO SPECIAL USE SPACE BOUNDARY CEILING OR

DECK.

D. ALL WALL LOCATED ITEMS WITHIN THE SPECIAL USE SPACE SHALL BE

SURFACE MOUNTED INCLUDING ALL ASSOCIATED CONDUIT

CONNECTIONS. ALL ITEMS TO BE MOUNTED WITH APPROVED

FASTENERS/HARDWARE TO MAINTAIN REQUIRED WALL STC VALUE. NO

EQUIPMENT, FURNISHINGS OR INFRASTRUCTURE WILL BE PERMITTED TO

BE RECESSED OR ENCLOSED IN ANY WALL WITHIN THE SPECIAL USE

SPACE.

E. ALL UTILITIES TO BE SURFACE MOUNTED. CONTRACTOR TO VERIFY WITH

ALL OTHER DISCIPLINES THAT EVERYTHING IS SURFACE MOUNTED.

F. ALL INSTALLED SCREWS INTO THE SPECIAL BOUNDARY ARE TO REMAIN.

LEAVE THEM AND INSTALL A NEW SCREW.

G. SCREWS WITHIN SPECIAL BOUNDARY WALLS ARE TO BE AS LIMITED AS

POSSIBLE.

01. CONCRETE FOUNDATION, REFER TO STRUCTURAL

02. PRECAST CONCRETE DOUBLE TEE, REFER TO STRUCTURAL

03. CONCRETE BEAM, REFER TO STRUCTURAL

04. CONCRETE FLOOR SLAB, REFER TO STRUCTURAL

05. RAF PEDESTAL 22"

06. RAF PEDESTAL 52"

07. RAF PANEL

08. SEISMIC ISOLATION SYSTEM (SIS), REFER TO STRUCTURAL

09. MECHANICAL EQUIPMENT, REFER TO MECHANICAL

10. PRECAST CONCRETE WALL, REFER TO STRUCTURAL. ALL EXTERIOR

SURFACES TO HAVE SILICONE ELASTOMERIC COATING.

11. CHASE

12. 2X2 ACT SYSTEM

13. PRECAST CONCRETE SPLASH BLOCK

14. ELEVATED CONCRETE SLAB ON GEOFOAM, REFER TO STRUCTURAL

15. 6" SPRAY FOAM INSULATION (R-39). INSTALL ON PRECAST DOUBLE TEE WEB

FACES AND TOP FLANGE ONLY.

16. CONCRETE TOPPING SLAB ON PRECAST DOUBLE TEES, REF. STRUCTURAL

17. SILICONE ELASTOMERIC ROOF COATING WITH FULL MESH

REINFORCEMENT ON CONCRETE TOPPING

18. ALUMINUM PROFILE OVER EXPANSION JOINT

19. ARCHITECTURAL REVEAL

20. PRECAST CONCRETE GUTTER, REFER TO STRUCTURAL

21. SILICONE ELASTOMERIC ROOF COATING WITH FULL MESH

REINFORCEMENT ON CONCRETE TOPPING THROUGH GUTTER EDGE FASCIA

ENDING AT VERTICAL WALL

22. LINE OF STRUCTURAL PILASTER BEYOND

23. PRECAST CONCRETE ROOF CORNICE WITH SILICONE ELASTOMERIC

COATING ON ALL EXPOSED SURFACES.

24. RAF PEDESTAL 10"

25. CANTILEVERED STRUCTURAL CONCRETE FLOOR SLAB WITH SILICONE

ELASTOMERIC COATING ON ALL EXPOSED SURFACES, REF. STRUCTURAL

26. STAINLESS STEEL DOWNSPOUT WITH STRAPS SPACED AT 5'-0" O.C.

DOWNSPOUT TO BE LOCATED AT PRE-CAST WALL JOINT/PILASTER.

REFER TO SHEETS 14CC-A-521 & 14CC-A-522 FOR DOWNSPOUT SIZING.

27. RF FOIL ADHERED TO RIGID BOARD INSULATION ALONG SECURE BOUNDAY

PERIMETER WALLS.

28. 20 GA METAL SHEET ADHERED TO CONCRETE SLAB WITH TO CREATE

SECURE BOUNDARY.

29. OPENING IN CURB FOR DRAINAGE OF MECHANICAL EQUIPMENT BAY.

REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS AND DETAILS.

30. MOLDED FIBERGLASS GRATING. 2" THICK WITH 2" x 2" SQUARE MESH.

31. STAINLESS STEEL LOUVERED FEBR RATED SCREEN WALL.

32. TAPERED CONCRETE FOUNDATION WALL WITH SILICONE ELASTOMERIC

COATING ON ALL EXPOSED AREAS. REFER TO STRUCTURAL

33. CONCRETE INFILL ALL THE WAY TO THE TOP OF THE PRECAST TEE

34. 1-HOUR FIRE RATED PRE-COMPRESSED FOAM EXPANSION JOINT SEAL.

35. CAST-IN-PLACE DRIP EDGE. REFER TO STRUCTURAL

36. GYP BD CEILING, REFER TO REFLECTED CEILING PLANS

37. PRECAST CONCRETE CORBEL. REFER TO STRUCTURAL

38. ELECTRICAL LIGHTING. REFER TO ELECTRICAL

39. ACOUSTICAL WALL PANELS

40. STAINLESS STEEL SINGLE PIECE COUNTER FLASHING

41. DUCT PENETRATION AT SECURE USE SPACE FOR DETAILS,

REFER TO MECHANICAL DRAWING 14CC-M-503

42. 20 GAUGE GALVANIZED SHEET METAL TO FORM RF SHIELDING BOUNDARY

43. 2" SEMI-RIGID MINERAL WOOL BOARD INSULATION ON PRECAST DOUBLE TEE

VERTICAL WEB. SEE DETAILS FOR COMPLETE INFORMATION.

44. 2" SEMI-RIGID MINERAL WOOL BOARD INSULATION (R-14)

45. CONCRETE SLAB AT FRONT ENTRY ONLY; REFER TO CIVIL EXTENDS THE

LENGTH OF THE RETAINING WALLS. SLOPES EAST TO WEST FOR DRAINAGE.

46. STEEL COLUMNS AND LATERAL BRACING FOR KNOWLEDGE WALL

SUPPORT TO BE ENGINEERED, SUPPLIED AND INSTALLED BY KNOWLEDGE

WALL VENDOR.

47. KNOWLEDGE WALL TO BE ENGINEERED, SUPPLIED AND INSTALLED BY

KNOWLEDGE WALL VENDOR.

48. 1.5" SPRAY FOAM INSULATION (R-14)

49. STAINLESS STEEL DIAMOND PLATE CATWALK WITH STAINLESS STEEL

GUARDRAILS, REFER TO STRUCTURAL FOR ROOF CONNECTION.

50. CAST-IN-PLACE CONCRETE RETAINING WALL, REFER TO CIVIL

51. HOSE BIB, REFER TO PLUMBING

52. KEEP OUT ZONE FOR SUSPENDED STRUCTURAL GRID SYSTEM (A

DELEGATED STRUCTURAL DESIGN ITEM). ZONE SHALL EXTEND FULL AREA

OF ROOMS 130 AND 135

53. BELOW GRADE WATERPROOFING APPLIED TO ALL EXTERIOR VERTICAL

AND HORIZONTAL SURFACES OF CONCRETE.

54. CHILLED WATER BUFFER PIPE, REFER TO MECHANICAL.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

KYM

AWK/DMK

KYM

/6 /2

:1 :4

P

M

C R e v it \l o c a l_

\P

C C

A

S e d m o n d s m

.r v t

14CC-A-304

C O

M M

A N

D C

E N

T E

R

S E

C T

IO

N

CMA

17323752

JLG MDE

G U

A M

C C

-A -3

FINAL DESIGN SUBMITTAL

SCALE: 3/16" = 1'-0"

A1

SPECIAL USE SPACE - SECTION

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

3/16" = 1'-0" 0 4' 8' 16'2'

GRAPHIC SCALE(S)

SHEET KEYNOTES

SHEET NAMING CONVENTION

GENERAL SHEET NOTES

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

W

A

LL

T Y

P E

K

A D

D

N O

V E

M B

E R

FIRST FLOOR

100'-0"

9' -0

2'

-0

6"

'-6

14CC-A-528

C1

F5

2' -1

/4

3'

-1

1/ 4"

4' -2

6'

-0

V A

R

IE

S V

A R

IE

S

2' -0

F5

14CC-A-521

A3 O.H.

14CC-A-531

C1

3' -7

1/

T O

T A

L D

IS

P

LA

Y

H

IE

G H

T

'-1

5/

'-0

2'

-0

F10

A. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS, REFER TO

SHEET 14GI-A-001.

B. ARCHITECTURAL FINISH FLOOR PLAN ELEVATION (100'-0"). INDICATES

THE TOP OF THE FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR ACTUAL

SITE REFERENCE ELEVATION.

C. SECURE USE SPACE BOUNDARY FLOOR TO SECURE USE SPACE

BOUNDARY CEILING OR DECK.

01. CONCRETE FOUNDATION, REFER TO STRUCTURAL

02. PRECAST CONCRETE DOUBLE TEE, REFER TO STRUCTURAL

03. CONCRETE BEAM, REFER TO STRUCTURAL

04. CONCRETE FLOOR SLAB, REFER TO STRUCTURAL

05. RAF PEDESTAL 22"

06. RAF PEDESTAL 52"

07. RAF PANEL

08. SEISMIC ISOLATION SYSTEM (SIS), REFER TO STRUCTURAL

09. MECHANICAL EQUIPMENT, REFER TO MECHANICAL

10. PRECAST CONCRETE WALL, REFER TO STRUCTURAL. ALL EXTERIOR

SURFACES TO HAVE SILICONE ELASTOMERIC COATING.

11. CHASE

12. 2X2 ACT SYSTEM

13. PRECAST CONCRETE SPLASH BLOCK

14. ELEVATED CONCRETE SLAB ON GEOFOAM, REFER TO STRUCTURAL

15. 6" SPRAY FOAM INSULATION (R-39). INSTALL ON PRECAST DOUBLE TEE WEB

FACES AND TOP FLANGE ONLY.

16. CONCRETE TOPPING SLAB ON PRECAST DOUBLE TEES, REF. STRUCTURAL

17. SILICONE ELASTOMERIC ROOF COATING WITH FULL MESH

REINFORCEMENT ON CONCRETE TOPPING

18. ALUMINUM PROFILE OVER EXPANSION JOINT

19. ARCHITECTURAL REVEAL

20. PRECAST CONCRETE GUTTER, REFER TO STRUCTURAL

21. SILICONE ELASTOMERIC ROOF COATING WITH FULL MESH

REINFORCEMENT ON CONCRETE TOPPING THROUGH GUTTER EDGE FASCIA

ENDING AT VERTICAL WALL

22. LINE OF STRUCTURAL PILASTER BEYOND

23. PRECAST CONCRETE ROOF CORNICE WITH SILICONE ELASTOMERIC

COATING ON ALL EXPOSED SURFACES.

24. RAF PEDESTAL 10"

25. CANTILEVERED STRUCTURAL CONCRETE FLOOR SLAB WITH SILICONE

ELASTOMERIC COATING ON ALL EXPOSED SURFACES, REF. STRUCTURAL

26. STAINLESS STEEL DOWNSPOUT WITH STRAPS SPACED AT 5'-0" O.C.

DOWNSPOUT TO BE LOCATED AT PRE-CAST WALL JOINT/PILASTER.

REFER TO SHEETS 14CC-A-521 & 14CC-A-522 FOR DOWNSPOUT SIZING.

27. RF FOIL ADHERED TO RIGID BOARD INSULATION ALONG SECURE BOUNDAY

PERIMETER WALLS.

28. 20 GA METAL SHEET ADHERED TO CONCRETE SLAB WITH TO CREATE

SECURE BOUNDARY.

29. OPENING IN CURB FOR DRAINAGE OF MECHANICAL EQUIPMENT BAY.

REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS AND DETAILS.

30. MOLDED FIBERGLASS GRATING. 2" THICK WITH 2" x 2" SQUARE MESH.

31. STAINLESS STEEL LOUVERED FEBR RATED SCREEN WALL.

32. TAPERED CONCRETE FOUNDATION WALL WITH SILICONE ELASTOMERIC

COATING ON ALL EXPOSED AREAS. REFER TO STRUCTURAL

33. CONCRETE INFILL ALL THE WAY TO THE TOP OF THE PRECAST TEE

34. 1-HOUR FIRE RATED PRE-COMPRESSED FOAM EXPANSION JOINT SEAL.

35. CAST-IN-PLACE DRIP EDGE. REFER TO STRUCTURAL

36. GYP BD CEILING, REFER TO REFLECTED CEILING PLANS

37. PRECAST CONCRETE CORBEL. REFER TO STRUCTURAL

38. ELECTRICAL LIGHTING. REFER TO ELECTRICAL

39. ACOUSTICAL WALL PANELS

40. STAINLESS STEEL SINGLE PIECE COUNTER FLASHING

41. DUCT PENETRATION AT SECURE USE SPACE FOR DETAILS,

REFER TO MECHANICAL DRAWING 14CC-M-503

42. 20 GAUGE GALVANIZED SHEET METAL TO FORM RF SHIELDING BOUNDARY

43. 2" SEMI-RIGID MINERAL WOOL BOARD INSULATION ON PRECAST DOUBLE TEE

VERTICAL WEB. SEE DETAILS FOR COMPLETE INFORMATION.

44. 2" SEMI-RIGID MINERAL WOOL BOARD INSULATION (R-14)

45. CONCRETE SLAB AT FRONT ENTRY ONLY; REFER TO CIVIL EXTENDS THE

LENGTH OF THE RETAINING WALLS. SLOPES EAST TO WEST FOR DRAINAGE.

46. STEEL COLUMNS AND LATERAL BRACING FOR KNOWLEDGE WALL

SUPPORT TO BE ENGINEERED, SUPPLIED AND INSTALLED BY KNOWLEDGE

WALL VENDOR.

47. KNOWLEDGE WALL TO BE ENGINEERED, SUPPLIED AND INSTALLED BY

KNOWLEDGE WALL VENDOR.

48. 1.5" SPRAY FOAM INSULATION (R-14)

49. STAINLESS STEEL DIAMOND PLATE CATWALK WITH STAINLESS STEEL

GUARDRAILS, REFER TO STRUCTURAL FOR ROOF CONNECTION.

50. CAST-IN-PLACE CONCRETE RETAINING WALL, REFER TO CIVIL

51. HOSE BIB, REFER TO PLUMBING

52. KEEP OUT ZONE FOR SUSPENDED STRUCTURAL GRID SYSTEM (A

DELEGATED STRUCTURAL DESIGN ITEM). ZONE SHALL EXTEND FULL AREA

OF ROOMS 130 AND 135

53. BELOW GRADE WATERPROOFING APPLIED TO ALL EXTERIOR VERTICAL

AND HORIZONTAL SURFACES OF CONCRETE.

54. CHILLED WATER BUFFER PIPE, REFER TO MECHANICAL.

FLOOR TIER 2

102'-6"

TOC EL

86'-10"

TOC FIRST FLOOR

COMPOSITE SLAB

98'-0"

TOC HIGH ROOF @

GRID D

136'-3"

F5

152 141

14CC-A-542

B3

14CC-A-528

C1

14CC-A-521

A3

K2

14CC-A-531

C1

F5

1 SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

KYM

AWK/DMK

KYM

/6 /2

:1 :4

P

M

C R e v it \l o c a l_

\P

C C

A

S e d m o n d s m

.r v t

14CC-A-315

C O

M M

A N

D C

E N

T E

R

W A

LL

S

E C

T

IO

N S

CMA

17323757

JLG MDE

G U

A M

C C

-A -3

FINAL DESIGN SUBMITTAL

SCALE: 1/4" = 1'-0"

A1

WALL SECTION

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

3/8" = 1'-0" 0 2' 4' 8'1'

1/4" = 1'-0" 0 4' 8' 12'2'

GRAPHIC SCALE(S)

SHEET KEYNOTES

SHEET NAMING CONVENTION

SCALE: 3/8" = 1'-0"

A2

WALL SECTION

GENERAL SHEET NOTES

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

W

A

LL

T Y

P E

K

A D

D

N O

V E

M B

E R

LOC

ASP

C A

C P

TP TP

A1

14CC-A-303

A1

14CC-A-304

154 153

150158 148

K2

K1

K1

S5

S5

S5

K1 R5

R5

R5

K1

K2

S5

S5

S5 S5

'-5

/4

27'-10 7/8" 9'-2 1/4" 22'-4 7/8"

'-2

'-2

/2

148B158A

148A

152A

153A154A

155A

29'-5 1/16" 30'-0 15/16"

23'-2" 12'-6 5/8" 23'-9 3/8"

14CC-A-413

A1

A3

C1

C3 14CC-A-414

A1

A3C3

C1

14CC-A-420 A2

14CC-A-415

A3

14CC-A-416

A1

14CC-A-418

14CC-A-418

14CC-A-412

C1

A2

A1

C1 A2

A3

C3

C1

A1

S5

151A

'-2

/2

'-6

/2

'-3

/4

S5

S5

150A

14CC-A-417

A1

A2

C1

C3

A1

A3C3

A1

14CC-A-411

14CC-A-541

C1 14CC-A-541

B1

V1

14CC-A-541

A1

14CC-A-541

C3

14CC-A-541

A1

14CC-A-541

B1

14CC-A-541

C1

4' -1

5/

8"

14CC-A-419 A2A3

K1

14CC-A-412

C1

'-7

/2

A1

14CC-A-412

A1

14CC-A-419

C1

C2C3

14CC-A-420

A3

C2C3

A1

K2

K2

A. FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS, REFER TO

SHEET 14GI-A-001.

B. ARCHITECTURAL FINISH FLOOR PLAN ELEVATION (100'-0"). INDICATES

THE TOP OF THE FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR ACTUAL

SITE REFERENCE ELEVATION.

C. SPECIAL USE SPACE BOUNDARY WALLS MUST BE PAINTED FROM

SPECIAL USE SPACE BOUNDARY FLOOR TO SPECIAL USE SPACE

BOUNDARY CEILING OR DECK, COLOR AS SPECIFIED. GYPSUM

BOARD SPECIAL USE SPACE BOUNDARY WALLS MUST BE FINISHED AS

SPECIFIED IN SPECIFICATION 09 29 00 FROM SPECIAL USE SPACE

BOUNDARY FLOOR TO SPECIAL USE SPACE BOUNDARY CEILING OR

DECK.

D. ALL WALL LOCATED ITEMS WITHIN THE SPECIAL USE SPACE SHALL BE

SURFACE MOUNTED INCLUDING ALL ASSOCIATED CONDUIT

CONNECTIONS. ALL ITEMS TO BE MOUNTED WITH APPROVED

FASTENERS/HARDWARE TO MAINTAIN REQUIRED WALL STC VALUE. NO

EQUIPMENT, FURNISHINGS OR INFRASTRUCTURE WILL BE PERMITTED TO

BE RECESSED OR ENCLOSED IN ANY WALL WITHIN THE SPECIAL USE

SPACE.

E. ALL UTILITIES TO BE SURFACE MOUNTED. CONTRACTOR TO VERIFY WITH

ALL OTHER DISCIPLINES THAT EVERYTHING IS SURFACE MOUNTED.

F. ALL INSTALLED SCREWS INTO THE SPECIAL BOUNDARY ARE TO REMAIN.

LEAVE THEM AND INSTALL A NEW SCREW.

G. SCREWS WITHIN SPECIAL BOUNDARY WALLS ARE TO BE AS LIMITED AS

POSSIBLE.

FIRST FLOOR

100'-0"

C

TOC FIRST FLOOR

COMPOSITE SLAB

98'-0"

TOC LOW ROOF AT

GRID C

125'-9 3/4"

14CC-A-541

B2

9' -0

2'

-0

14CC-A-542

A3

R5

14CC-A-541

A3

14CC-A-541

A2

SIM.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

KYM

AWK/DMK

KYM

/6 /2

:1 :5

P

M

C R e v it \l o c a l_

\P

C C

A

S e d m o n d s m

.r v t

14CC-A-411

C O

M M

A N

D C

E N

T E

R

E N

LA

R

G E

D P

LA

N

CMA

17323765

JLG MDE

G U

A M

C C

-A -4

FINAL DESIGN SUBMITTAL

SCALE: 3/16" = 1'-0"

A2

ENLARGED FLOOR PLAN

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE NUMBERS

SITE #

SITE 01

SITE 02

SITE 14

BUILDING ID

AC - ACCESS CONTROL POINT

CC - COMMAND CENTER

FP - FIRE PUMP BUILDING

GI - GENERAL

PP - POWER PLANT

SF - SECURITY FORCE

ST - SITE

1/2" = 1'-0" 0 2' 4' 6'1'

3/16" = 1'-0" 0 4' 8' 16'2'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

SHEET KEYNOTES

SHEET NAMING CONVENTION

SCALE: 1/2" = 1'-0"

A1

RECESSED ENTRANCE CEILING SECTION

01. CLEAN AGENT CANNISTERS, REFER TO FIRE PROTECTION DRAWINGS

02. CLEAN AGENT CONTROL PANEL, REFER TO FIRE PROTECTION

DRAWINGS

03. FIRE ALARM CONTROL PANEL, REFER TO FIRE PROTECTION

DRAWINGS

04. SPECIAL USE SPACE BOUNDARY

TYP

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

W

A

LL

T Y

P E

K

A D

D

N O

V E

M B

E R

UNDERSIDE OF

STRUCTURE ABOVE

CEILING, WHERE SCHEDULED

(1) LAYER 5/8" GYP BD EACH SIDE

MTL STUD @ 16" OC

FINISH FLOOR AS SCHEDULED

HEAD

PLAN

BASE

DEFLECTION TRACK W/ 1/2"

COMPRESSION OR EXTENSION.

SECURED TO FLR OR ROOF DECK

WALL BASE AS SCHEDULED

SPRAY FOAM INSULATION

THERMAL BATT INSULATION

HEAD

PLAN

BASE

CEILING, WHERE SCHEDULED

(1) LAYER 5/8" TYPE "X" GYPSUM

BOARD EACH SIDE @ B7, B8,

(2) LAYERS EACH SIDE @ B9

MTL STUD @ 16" OC

FINISH FLOOR AS SCHEDULED

FIRE RATED SEALANT

BOTH SIDES

WALL BASE AS SCHEDULED

THERMAL BATT INSULATION

UNDERSIDE OF STRUCTURE ABOVE

SEMI-RIGID FIRE SAFING INSUL TO FIT AGAINST

STRUCTURE ABOVE TO PROVIDE FIRE/ACOUSTICAL

RATED SYSTEM WHERE SCHED.

SEAL ALL PERIM EDGES, BOTH SIDES OF WALL W/

ACOUSTICAL AND/OR FIRE RATED SEALANT

DEFLECTION TRACK W/ 100% COMPRESSION OR

EXTENSION - 1/2 JOINT. SECURED TO UNDERSIDE OF

STRUCTURE ABOVE (HEAD WALL DETAIL HW-D-0119)

SPRAY FOAM INSULATION

CEILING, WHERE SCHED

(1) LAYER 5/8" GYP BD @ WALL

TYPES F5, F6, F8, F9 AND F10

(2) LAYERS OF 5/8" GYP BD @

WALL TYPE F7

METAL STUDS @ 16" OC

TOP ON CONCRETE SLAB

HEAD

PLAN

BASE

RAF, WHERE SCHEDULED

EXTEND GYPSUM BOARD

6" BOVE CEILING

WALL BASE AS SCHEDULED

ACOUSTICAL SEALANT AT TOP

AND BOTTOM OF WALL

6"

1 1/2" SPRAY FOAM

INSULATION AS SCHEDULED

EXTEND INSULATION FULL

HEIGHT ON EXTERIOR WALLS

CEILING, WHERE SCHEDULED

(1) LAYER 5/8" GYP BD ON EACH SIDE

AT WALL TYPE S4

METAL STUDS @ 16" OC

FINISH FLOOR

FILL STUD CAVITY W/ ACOUSTICAL

INSULATION PER SCHEDULE

HEAD

PLAN

BASE

(1) LAYER 5/8" GYP BD ON ONE SIDE

(2) LAYERS 5/8" GYP BD ON ONE SIDE

AT WALL TYPE S5

UNDERSIDE OF STRUCTURE ABOVE

SEMI-RIGID FIRE SAFING INSUL TO FIT AGAINST

STRUCTURE ABOVE TO PROVIDE FIRE/ACOUSTICAL

RATED SYSTEM WHERE SCHEDULED.

SEAL ALL PERIMETER EDGES,

BOTH SIDES OF WALL W/ ACOUSTICAL

AND/OR FIRE RATED SEALANT

DEFLECTION TRACK W/ 100% COMPRESSION

OR EXTENSION - 1/2 JOINT. SECURED TO

UNDERSIDE OF STRUCTURE ABOVE

(HEAD WALL DETAIL HW-D-0119)

WALL BASE AS SCHEDULED

AT ACOUSTICAL WALLS SET BOTTOM TRACK

IN FULL BED OF ACOUSTICAL SEALANT

RAF FLOOR AS SCHEDULED

SPRAY FOAM INSULATION

CEILING,

WHERE SCHEDULED

(1) LAYER 5/8" TYPE "X" GYP BD

ON BOTH SIDES

(2) 3 5/8" METAL STUDS @ 16" OC

TOP OF CONCRETE SLAB

FINISH FLOOR

FILL STUD CAVITY W/ ACOUSTICAL

INSULATION PER SCHEDULE

HEAD

PLAN

BASE

CONTROLLED SIDE UNCONTROLLED SIDE

RF FOIL PLACED BETWEEN

GYPSUM BOARD PANELS

WALL TYPE R NOTES:

1. WALL SHALL MEET THE SOUND GROUP 4 REQUIREMENTS IN IC-TECH SPEC ICD/ICS 705 AND FIELD TEST RESULTS SHALL BE NIC 45 OR BETTER WHEN TESTED IN ACCORDANCE W/ ASTM E336.

2. GYPSUM BOARD SEAMS TO BE STAGGERED, IF MORE THAN ONE LAYER OF GYPSUM BOARD IS

INSTALLED ON A SINGLE SIDE.

3. INSULATION BATTS TO BE SECURED TO METAL STUDS.

4. ALL SPECIAL USE SPACE PERIMETER STUD FRAMING SHALL BE 16 GAUGE AND 16" OC MAXIMUM

WALL BASE AS SCHEDULED

SEE GENERAL NOTE L

FOR RF SHIELDING

INSTRUCTIONS

AT ACOUSTICAL WALLS

SET BOTTOM TRACK IN FULL BED

OF ACOUSTICAL SEALANT

(1) LAYER 5/8" TYPE "X" GYP BD

ON BOTH SIDES

FILL STUD CAVITY

W/ ACOUSTICAL INSULATION

PER SCHEDULE, TYPICAL

RF FOIL PLACED BETWEEN

GYPSUM BOARD PANELS

(2) LAYERS 5/8" TYPE "X"

GYPSUM BOARD

(2) LAYERS 5/8" TYPE "X"

GYPSUM BOARD PANELS

HEAD

PLAN

BASE

SCHEDULED CEILING WHERE OCCURS

3 5/8" 16 GAUGE COLD FORMED METAL STUD WALL

FRAMING @ 16" OC, TYPICAL ALL WALL FRAMING

THAT FORMS THE SPECIAL USE SPACE PERIMETER

RAISED ACCESS FLOORING

ONE LAYER 5/8" GWB

PRECAST CONCRETE WALL,

REFER TO STRUCTURAL

RF FOIL FULLY ADHERED TO INSULATION

BOARD. EXTEND TO CONCRETE SLAB

SEE GENERAL NOTE L

FOR RF SHIELDING INSTRUCTIONS

BASE AS SCHEDULED

ENTIRE WALL ASSEMBLY FINISHED AND

PAINTED FROM TRUE FLOOR TO

TRUE CEILING ON EXPOSED SIDE

1" POLYISO BOARD INSULATION ADHERED

TO PRECAST CONCRETE WALL PANEL

WALL TYPE R NOTES:

1. GYPSUM BOARD SEAMS TO BE STAGGERED, IF MORE THAN ONE LAYER OF GYPSUM BOARD IS

INSTALLED ON A SINGLE SIDE.

2. ALL SPECIAL USE SPACE PERIMETER STUD FRAMING SHALL BE 16 GAUGE AND 16" OC MAXIMUM.

3. ALL INTERIOR WALLS SHALL EXTEND TO THE RF FOIL PLANE TO MAINTAIN REQUIRED STC WALL

RATINGS.

REFER TO DETAIL B3/14CC-A-542 FOR

RF SHIELDING WALL TO DOUBLE TEE

TRANSITION AT CONCRETE CORBEL

ON EXTERIOR WALL ONLY: 1 1/2" SPRAY FOAM

INSULATION EXTENDED TO ROOF ABOVE

CONTINUOUS ACOUSTIC BATT INSULATION

IN SOFFIT FRAMING

COLD FORMED "Z" CHANNEL FRAMING @ 48" OC

VERTICALLY FOR METAL STUD CONNECTION

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V F

A C

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

P R

O J E

C T

S

IT

E

C O

M M

A N

D C

E N

T E

R

N A

V F

A C

P A

C

IF

IC

1812861

JC

Jacobs/B&V, A Joint Venture (Federal Services) 1003 Bishop Street Suite 1340 Honolulu, HI 96813

A/E Task Order No. N6274223F0324

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

KYM

AWK/DMK

KYM

/6 /2

:1 :5

P

M

C R e v it \l o c a l_

\P

C C

A

S e d m o n d s m

.r v t

14CC-A-501

C O

M M

A N

D C

E N

T E

R

A R

C H

P A

R T

IT

IO

N T

Y P

E S

CMA

17323788

JLG MDE

G U

A M

C C

-A -5

FINAL DESIGN SUBMITTAL

SCALE: 1 1/2" = 1'-0"

C1

WALL DETAIL - TYPE A - FULL HEIGHT WALLS

SCALE: 1 1/2" = 1'-0"

C2

WALL DETAIL - TYPE B - FIRE RATED WALLS

SCALE: 1 1/2" = 1'-0"

C3

WALL DETAIL - TYPE F - FURRED WALLS

SCALE: 1 1/2" = 1'-0"

A2

WALL DETAIL - TYPE S - STC RATED WALLS

WALL TYPE WALL WIDTH STUD WIDTH

INSULATION

THICKNESS NOTES

A2 7 1/4" 6" -

A3 9 1/4" 8" -

A4 9 1/4" 8" - REFER TO SHEET NOTE M.

A5 8 5/8" 8" - PARTIAL HEIGHT WALL, GYPSUM

BOARD ON VISIBLE SIDE ONLY

WALL

TYPE

WALL

WIDTH

STUD

WIDTH

FIRE

RATING

UL

ASSEMBLY # STC NOTE

B6 10 1/2" 8" 2 HR UL U419 - REFER TO SHEET NOTE M.

B7 9 1/4" 8" 1 HR UL U419 -

B8 9 1/4" 8" 1 HR UL U419 50 ADD 8" ACOUSTICAL

INSULATION

B9 10 1/2" 8" 2 HR UL U419 50 ADD 8" ACOUSTICAL

INSULATION

WALL TYPE WALL WIDTH STUD WIDTH

INSULATION

THICKNESS NOTE

F5 2 1/8" 1 1/2" 1 1/2" REFER TO SHEET NOTE

F6 2 1/8" 1 1/2" 1 1/2" REFER TO SHEET NOTE M.

F7 9 1/4" 8" -

F8 8 5/8" 8" - REFER TO SHEET NOTE M.

F9 4 1/4" 3 5/8" - REFER TO SHEET NOTE M.

F10 6 5/8" 6" -

WALL

TYPE

WALL

WIDTH

STUD

WIDTH STC

INSULATION

THICKNESS NOTE

S3 9 1/4" 8" 50 8" REFER TO SHEET NOTE M.

S4 9 1/4" 8" 50 8"

S5 9 7/8" 8" 50 8" WITHIN SPECIAL USE SPACE ONLY

A. FOR WALL FINISH, BASE AND CEILING TYPE, REFER TO ROOM FINISH

SCHEDULE 14CC-A-602.

B. PROVIDE CONTINUOUS FIRE RATED, ACOUSTICAL RATED SEALANT OR

COMBINATION OF BOTH AROUND THE WALL PERIMETERS, SEAMS AND

AT ALL PENETRATIONS IN SOUND AND FIRE RATED PARTITIONS (I.E. AT

ELECTRICAL BOXES, DUCTS, PIPES & TOILET ACCESSORIES).

C. PROVIDE FIRE RETARDANT WOOD BLOCKING OR STEEL STRAPPING

FOR ALL HANDRAILS, WALL HUNG FIXTURES, EQUIPMENT, WALL

MOUNTED ARCHITECTURAL WOODWORK, FINISH CARPENTRY,

FURNITURE, ACCESSORIES, DOOR BUMPERS, TOILET PARTITIONS, AND

ANYWHERE CALLED FOR IN SPECIFICATIONS.

D. WHERE UL NUMBERS ARE SHOWN, A SIMILAR PRODUCT AND

ASSEMBLY MAY BE SUBSTITUTED WITH EQUIVALENT PROPERTIES AND

TESTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY.

E. ALL FIRE AND SMOKE RATED PARTITIONS MUST BE LABELED, IN

ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES

WITH A MINIMUM 3” HIGH MINIMUM STENCILED LETTERS WITH A

MINIMUM 3/8" STROKE IN CONTRASTING COLOR TO THE WALL-BD

EVERY 30 FEET MAXIMUM ON CENTER AND WITHIN 15 FEET OF THE END

OF THE WALL WITH THE FOLLOWING WORDING “FIRE AND/OR SMOKE

BARRIER- PROTECT ALL OPENINGS” VISIBLE FROM ANYWHERE ABOVE

THE CEILING AS REQUIRED BY IBC 703.7.

F. PROVIDE VERTICAL AND HORIZONTAL CONTROL JOINTS IN GYPSUM

BOARD SURFACES AT 30'-0" OC MAXIMUM, UNLESS NOTED OTHERWISE.

LOCATE CONTROL JOINTS AT TOP CORNERS OF DOORS OR OPENINGS

TO THE GREATEST EXTENT POSSIBLE.

G. IF GYPSUM BOARD IS ONE SIDE ONLY, PROVIDE HORIZONTAL BRIDGING

AT 5'-0" OC VERTICALLY.

H. CONTRACTOR IS RESPONSIBLE FOR USING THE MINIMUM SIZE,

GAUGE AND SPACING REQUIRED FOR ALL LIGHT GAUGE FRAMING.

NOTIFY THE ARCHITECT WHERE DISCREPANCIES OCCUR. HEIGHT

LIMITATIONS ARE BASED UPON 5 PSF SURFACE LOAD, L/240

DEFLECTION LIMIT, AND UNBRACED LENGTHS, UNLESS NOTED

OTHERWISE. WALLS WITH BRITTLE OR VENEER ASSEMBLIES MUST BE

L/360 DEFLECTION LIMIT.

I. PROVIDE MINIMUM 20 GAUGE DOUBLE STUD FRAMING AT DOOR AND

OPENING JAMBS MUST CONTINUE TO UNDERSIDE OF DECK ABOVE OR

TOP OF PARTITION, UNLESS NOTED OTHERWISE. WHERE SPECIALTY

DOORS ARE INSTALLED, CONTRACTOR MUST CONSULT THE

MANUFACTURE FOR ATTACHMENT DETAILS.

J. CONTRACTOR MUST PROVIDE CEMENTITIOUS BACKER UNITS OR

GLASS MAT WATER-RESISTANT GYPSUM TILE BACKING BOARD IN

SHOWER LOCATIONS. FIBER-REINFORCED WATER-RESISTANT GYPSUM

BACKING BOARD MUST BE USED IN ALL OTHER LOCATIONS WHERE

TILE IS SCHEDULED. WALLS IN TOILET ROOMS, BEHIND WATER

FOUNTAINS AND AROUND CABINETRY THAT CONTAIN SINKS WHERE

TILE IS NOT SCHEDULED MUST RECEIVE MOLD RESISTANT/ANTI-

MICROBIAL GYPSUM BOARD. CONTRACTOR IS RESPONSIBLE FOR

MAINTAINING THE FIRE AND SOUND RATING AS INDICATED ON THE

DRAWINGS FOR WALLS THAT REQUIRE SPECIALTY GYPSUM BOARD

PRODUCTS.

K. FOR WALL TYPES "K" AND "R", WHERE LISTED AS PER IC TECH SPEC

ICD/ICS 705, THE CONTRACTOR MUST FOLLOW THE INSTALLATION

DESIGN GUIDELINES PER IC TECH SPEC FOR ICD/ICS 705. CONTRACTOR

MUST ALSO FASTEN ACOUSTICAL INSULATION TO STUDS TO AVOID

SLIPPING AND ENSURE ALL STUD CAVITIES INCLUDING HEADERS AND

JAMBS ARE FILLED WITH ACOUSTICAL INSULATION.

L. 20 GAGE SHEET METAL RF BOUNDARY ON CONCRETE SLAB OVERLAP

ALL PANELS 6" FULLY ATTACHED TO CONCRETE SLAB WITH

NON-ORGANIC MOLD RESISTANT ADHESIVE PROVIDE 3" WIDE DOUBLE

SIDED ELECTRICALLY CONDUCTIVE TAPE BETWEEN LAYERS AT

OVERLAPS. PROVIDE 6" WIDE SINGLE SIDED ELECTRICALLY

CONDUCTIVE TAPE AT PANEL TO PANEL TRANSITIONS.

M. MOLD AND MOISTURE RESISTANT GYPSUM BOARD ON VESTIBULE SIDE

OF THE PARTITION. ROOM NUMBERS: 101, 120B, AND 147.

N. 1 1/2" SPRAY FOAM INSULATION ONLY AT F5 WALLS ON EXTERIOR

CONCRETE WALLS. F5 WALLS ON INTERIOR CONCRETE DO NOT

REQUIRE INSULATION.

O. ON FIRE RATED WALL TYPE K2 BETWEEN SPECIAL USE SPACE AND

ROOM 141: 1" RIGID MINERAL WOOL BOARD WITH GLASS MAT FACER

ADHERED TO PRECAST WALL PANELS IN LIEU OF 1" POLYISO BOARD

INSULATION ADHERED TO PRECAST CONCRETE WALL PANEL. ORIENT

GLASS MAT FACER SIDE INTO SPECIAL USE SPACE TO ADHERE RF FOIL

TO PRIOR TO MECHANICALLY FASTENING WALL STUDS TO Z FURRING.

14CC-A-101

SITE #

BUILDING ID DISCIPLINE

CONSECUTIVE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .