This is a product specification document for the EDD-401 Stationary Louver with Dual Drainable Blade manufactured by Greenheck Fan Corporation.

The EDD-401 is an extruded aluminum louver featuring heavy gauge 6063-T5 aluminum construction with a 4-inch frame and dual drainable blades positioned at 37° and 45° on 4-inch centers. The louver has a 4-inch depth and mechanically fastened construction with a mill finish. Minimum size is 12 inches by 12 inches, and maximum single section size is 120 inches by 120 inches, limited to 70 square feet. The unit can withstand a 25 PSF wind load. Key performance specifications include a free area of 8.22 square feet (51.4% of louver area), a beginning point of water penetration at 992 fpm free area velocity with a maximum intake volume of 8,154 cfm, and a pressure drop of 0.078 inches of water gauge at 6,000 cfm intake. The louver is AMCA certified and tested in accordance with AMCA Publication 511 and AMCA Standard 500-L. Available options and accessories include bird screens, blank-off panels, extended sill, filter racks, flange frames, glazing frames, hinged frames, insect screens, mounting angles, security bars, architectural finishes, and welded construction alternatives. The document includes detailed free area charts for various louver dimensions and performance graphs showing airflow resistance and water penetration characteristics.

View the file

Other files

File Type Posted
27. Amendment 47PB5126R0008 0008 2026 07 13.pdf PDF
3. Agreement Rev 2 2026 06 18.pdf PDF
25. Amendment 47PB5126R0008 0007 2026 06 18.pdf PDF
6. WD VT20250027 2026 05 18.pdf PDF
1. Solicitation Rev 1_2026 06 11.pdf PDF
2. SF1442 Rev 1 dated 2026 06 15.pdf PDF
3. Agreement Rev 1 2026 06 12.pdf PDF
21. Amendment 47PB5126R0008 0006 2026 06 15.pdf PDF
20. Amendment 47PB5126R0008 0005 2026 06 02.pdf PDF
19. Amendment 47PB5126R0008 0004 2026 05 29.pdf PDF
16. Alburg Springs - Port Signage SOW-ASR 01.pdf PDF
15. Amendment 47PB5126R0008 0003 2026 05 21.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes_Rev 1 Amendment 0002_ 2026 05 15.pdf PDF
14. Amendment 47PB5126R0008 0002 2026 05 15.pdf PDF
13. Amendment 47PB5126R0008 0001 2026 05 12.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes 2026 05 06.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes 2026 05 06.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes 2026 05 06.pdf PDF
RP - Vertical Radiant Panel Cutsheet.pdf PDF
RG - Return Grille Cutsheet.pdf PDF
SG - Supply Grille Cutsheet.pdf PDF
ET - Expansion Tank Cutsheet.pdf PDF
FT - Fin Tube Cutsheet.pdf PDF
GFT - Glycol Feed Tank Cutsheet.pdf PDF
BT - Buffer Tank Cutsheet.pdf PDF
FB - Filter Box Cutsheet.pdf PDF
PUH - Propeller Unit Heater Cutsheet.pdf PDF
GI and GR - Gravity Intake and Relief Cutsheet.pdf PDF
DH - Duct Mounted Humidifier Cutsheet.pdf PDF
SG and EG - Security Grille Cutsheet.pdf PDF
BSF - Booth Supply Fan Cut Sheet.pdf PDF
RP - Horizontal Radiant Panel Cutsheet.pdf PDF
AS - Air Separator Cutsheet.pdf PDF
EHC - Electric Heating Coil Cutsheet.pdf PDF
2026-02-06 Review of Proposed Renovations - Historic Context (1).pdf PDF
4. GSA527-21a 2026 04 15.pdf PDF
FCU - Fan Coil Unit Cutsheet.pdf PDF
6. WD VT20250027 2026 04 15.pdf PDF
CP and GP - Pump Cutsheets.pdf PDF
3. Agreement 2026 04 15.pdf PDF
EH - Electric Wall Heater Cutsheet.pdf PDF
7. PBS PPQ 2026 04 15.pdf PDF
GSHP - Ground Source Heat Pump Cutsheet.pdf PDF
HP and CU - Heat Pump Mini-Split Cutsheet.pdf PDF
8. Tips on Preparing a Subcontracting Plan 2026 04 15.pdf PDF
HUM - Steam Humidifier Cutsheet.pdf PDF
Alburg Springs VT LPOE Code Report - 20260206 (1).pdf PDF
9. Model Subcontracting Plan 2026 04 15.docx DOCX document
5. Proprietary Information Agreement 2026 04 15.docx DOCX document
EF - Exhaust Fan Cutsheet.pdf PDF
Show 40 more

Latest 50 of 56 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EDD-401

Stationary Louver, Dual Drainable Blade

Extruded Aluminum

Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness

Blades Dual drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned 37º and 45º on approximately 4 in. (102 mm) centers

Louver Depth 4 in. (102 mm)

Construction Mechanically fastened

Finish Mill

Minimum Size 12 in. W x 12 in. H (305 mm W x 305 mm H)

Maximum Single Section Size

120 in. W x 120 in. H (3048 mm W x 3048 mm H) Limited to 70 sq. ft. (6.5 sq. m)

Wind Load 25 PSF (1.2 kPa)

EDD-401 August 2023

Document Links Louver Finishes & Colors

Louver Product Selection Guide

Louver Products Catalog

Louver Warranty Statement

Options and Accessories

• Bird Screen

• Blank Off Panels

• Extended Sill

• Filter Rack/Filter

• Flange Frame

• Glazing Frame

• Hinged Frame

• Insect Screen

• Mounting Angles

• Security Bars

• Variety of Architectural Finishes

• Welded Construction

Standard Details EDD-401 Standard Details

Free Area

Area 8.22 sq. ft. (0.764 sq. m)

Percent 51.4%

Performance at Beginning Point of Water Penetration

Free Area Velocity 992 fpm (5.039 m/s)

Max Intake Volume 8,154 cfm (3.848 m³/s)

Performance at 6,000 CFM (2.832 m³/s)Intake

Pressure Drop 0.078 in. wg (0.019 kPa)

Performance of 48 in. x 48 in. (1219 mm x 1219 mm) Louver

Structural reinforcing members may be required to adequately support and install multiple louver sections within a large opening. Structural reinforcing members along with any associated installation hardware is not provided by Greenheck unless indicated otherwise by Greenheck.

Options and accessories including, but not limited to, screens, filter racks, louver doors, and blank off panels are not subject to structural analysis unless indicated otherwise by Greenheck.

Greenheck Fan Corporation certifies that the EDD-401 louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to Water Penetration and Air Performance ratings.

Louvers were tested in accordance with AMCA Standard 500-L.

Performance Ratings https://content.greenheck.com/public/DAMProd/Original/10002/louverfinishes_other.pdf https://content.greenheck.com/public/DAMProd/Original/10002/InteractiveLouverProductSelectionGuide.pdf https://content.greenheck.com/public/DAMProd/Original/10002/LouverProducts_catalog.pdf https://content.greenheck.com/public/DAMProd/Original/10002/LouverProduct_warranty.pdf https://content.greenheck.com/public/DAMProd/Original/10005/birdscreen_details.pdf https://content.greenheck.com/public/DAMProd/Original/10005/blankoff_detail.pdf https://content.greenheck.com/public/DAMProd/Original/10005/sill%20extension.pdf https://content.greenheck.com/public/DAMProd/Original/10005/Filter_Rack_Detail.pdf https://content.greenheck.com/public/DAMProd/Original/10005/flange.pdf https://content.greenheck.com/public/DAMProd/Original/10015/GlazingAdapter_detail.pdf https://content.greenheck.com/public/DAMProd/Original/10015/Hinge_detail.pdf https://content.greenheck.com/public/DAMProd/Original/10006/HingeDetail_June2013_submittal.pdf https://content.greenheck.com/public/DAMProd/Original/10005/insect_screen_detail.pdf https://content.greenheck.com/public/DAMProd/Original/10005/Anchor.pdf https://content.greenheck.com/public/DAMProd/Original/10005/security_bar_detail.pdf https://content.greenheck.com/public/DAMProd/Original/10002/louverfinishes_other.pdf https://content.greenheck.com/public/DAMProd/Original/10006/SubframeDetail_December2003_submittal.pdf https://content.greenheck.com/public/DAMProd/Original/10014/EDD_401_details.pdf

EDD-401

Stationary Louver, Dual Drainable Blade

Extruded Aluminum

EDD-401 August 2023

Free Area Chart Free Area Chart shows free area in square feet and square meters.

Louver Height Inches (Meters)

Louver Width in Inches (Meters)

12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120

0.30 0.46 0.61 0.76 0.91 1.07 1.22 1.37 1.52 1.68 1.83 1.98 2.13 2.29 2.44 2.59 2.74 2.90 3.05

12 0.21 0.34 0.48 0.61 0.75 0.88 1.02 1.12 1.25 1.39 1.52 1.65 1.79 1.92 2.06 2.16 2.29 2.43 2.56

0.30 0.02 0.03 0.04 0.06 0.07 0.08 0.09 0.10 0.12 0.13 0.14 0.15 0.17 0.18 0.19 0.20 0.21 0.23 0.24

18 0.51 0.83 1.16 1.49 1.82 2.14 2.47 2.72 3.04 3.37 3.70 4.03 4.36 4.68 5.01 5.26 5.58 5.91 6.24

0.46 0.05 0.08 0.11 0.14 0.17 0.20 0.23 0.25 0.28 0.31 0.34 0.37 0.41 0.43 0.47 0.49 0.52 0.55 0.58

24 0.71 1.17 1.63 2.09 2.56 3.02 3.48 3.82 4.29 4.75 5.21 5.67 6.13 6.59 7.05 7.40 7.86 8.32 8.78

0.61 0.07 0.11 0.15 0.19 0.24 0.28 0.32 0.35 0.40 0.44 0.48 0.53 0.57 0.61 0.65 0.69 0.73 0.77 0.82

30 0.82 1.35 1.88 2.42 2.95 3.48 4.01 4.41 4.94 5.48 6.01 6.54 7.07 7.60 8.14 8.54 9.07 9.60 10.13

0.76 0.08 0.13 0.17 0.22 0.27 0.32 0.37 0.41 0.46 0.51 0.56 0.61 0.66 0.71 0.76 0.79 0.84 0.89 0.94

36 1.21 2.00 2.79 3.58 4.37 5.15 5.94 6.53 7.32 8.11 8.90 9.68 10.47 11.26 12.05 12.64 13.43 14.22 15.00

0.91 0.11 0.19 0.26 0.33 0.41 0.48 0.55 0.61 0.68 0.75 0.83 0.90 0.97 1.05 1.12 1.17 1.25 1.32 1.39

42 1.32 2.18 3.03 3.89 4.75 5.61 6.46 7.10 7.96 8.82 9.68 10.53 11.39 12.25 13.10 13.75 14.60 15.46 16.32

1.07 0.12 0.20 0.28 0.36 0.44 0.52 0.60 0.66 0.74 0.82 0.90 0.98 1.06 1.14 1.22 1.28 1.36 1.44 1.52

48 1.68 2.77 3.86 4.95 6.04 7.13 8.22 9.04 10.13 11.22 12.31 13.40 14.49 15.58 16.67 17.48 18.57 19.66 20.75

1.22 0.16 0.26 0.36 0.46 0.56 0.66 0.76 0.84 0.94 1.04 1.14 1.24 1.35 1.45 1.55 1.62 1.73 1.83 1.93

54 1.77 2.92 4.07 5.22 6.37 7.52 8.67 9.53 10.68 11.83 12.98 14.13 15.28 16.43 17.58 18.44 19.59 20.74 21.89

1.37 0.16 0.27 0.38 0.48 0.59 0.70 0.81 0.89 0.99 1.10 1.21 1.31 1.42 1.53 1.63 1.71 1.82 1.93 2.03

60 2.14 3.53 4.92 6.32 7.71 9.10 10.49 11.53 12.92 14.31 15.70 17.09 18.48 19.87 21.26 22.31 23.70 25.09 26.48

1.52 0.20 0.33 0.46 0.59 0.72 0.85 0.97 1.07 1.20 1.33 1.46 1.59 1.72 1.85 1.98 2.07 2.20 2.33 2.46

66 2.27 3.74 5.21 6.68 8.15 9.62 11.09 12.20 13.67 15.14 16.61 18.08 19.55 21.02 22.49 23.60 25.07 26.54 28.01

1.68 0.21 0.35 0.48 0.62 0.76 0.89 1.03 1.13 1.27 1.41 1.54 1.68 1.82 1.95 2.09 2.19 2.33 2.47 2.60

72 2.61 4.30 5.99 7.68 9.38 11.07 12.76 14.03 15.72 17.41 19.10 20.79 22.49 24.18 25.87 27.14 28.83 30.52 32.21

1.83 0.24 0.40 0.56 0.71 0.87 1.03 1.19 1.30 1.46 1.62 1.77 1.93 2.09 2.25 2.40 2.52 2.68 2.84 2.99

78 2.77 4.57 6.36 8.16 9.96 11.75 13.55 14.90 16.69 18.49 20.29 22.08 23.88 25.68 27.47 28.82 30.62 32.41 34.21

1.98 0.26 0.42 0.59 0.76 0.93 1.09 1.26 1.38 1.55 1.72 1.89 2.05 2.22 2.39 2.55 2.68 2.84 3.01 3.18

84 3.07 5.06 7.05 9.04 11.03 13.02 15.00 16.50 18.49 20.48 22.47 24.46 26.45 28.43 30.42 31.92 33.91 35.90 37.89

2.13 0.29 0.47 0.65 0.84 1.02 1.21 1.39 1.53 1.72 1.90 2.09 2.27 2.46 2.64 2.83 2.97 3.15 3.34 3.52

90 3.27 5.40 7.52 9.64 11.77 13.89 16.01 17.60 19.73 21.85 23.97 26.10 28.22

2.29 0.30 0.50 0.70 0.90 1.09 1.29 1.49 1.64 1.83 2.03 2.23 2.42 2.62

96 3.38 5.58 7.77 9.96 12.16 14.35 16.55 18.19 20.39 22.58 24.77 26.97 29.16

2.44 0.31 0.52 0.72 0.93 1.13 1.33 1.54 1.69 1.89 2.10 2.30 2.51 2.71

102 3.78 6.23 8.68 11.13 13.58 16.03 18.48 20.31 22.76 25.21 27.66 30.11 32.56

2.59 0.35 0.58 0.81 1.03 1.26 1.49 1.72 1.89 2.11 2.34 2.57 2.80 3.02

108 3.88 6.40 8.92 11.44 13.96 16.48 19.00 20.88 23.40 25.92 28.44 30.96 33.48

2.74 0.36 0.59 0.83 1.06 1.30 1.53 1.77 1.94 2.17 2.41 2.64 2.88 3.11

114 4.24 6.99 9.75 12.50 15.25 18.00 20.75 22.82 25.57 28.32 31.07 33.82 36.58

2.90 0.39 0.65 0.91 1.16 1.42 1.67 1.93 2.12 2.38 2.63 2.89 3.14 3.40

120 4.33 7.15 9.96 12.77 15.58 18.39 21.20 23.31 26.12 28.93 31.75 34.56 37.37

3.05 0.40 0.66 0.93 1.19 1.45 1.71 1.97 2.17 2.43 2.69 2.95 3.21 3.47

4.6 4.7 4.8 4.9 5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6.0

900 950 1000 1050 1100 1150 1200

0.00

0.05

0.10

0.15

0.20

0.25

0.30

Test Size 48 in. x 48 in.

Test Period 15 minutes

Standard Air - .075 lb/ft3 m/s:

ft/min:

ml/m2 oz/ft2

W at er P en et ra tio n pe r U ni t F re e A re a

Free Area Velocity

200200 300 400 500 600 700 8009001000 2000 3000

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09 0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

2 3 4 5 6 7 8 9 10

Pa

Ex ha us t

In ta ke

Test Size 48 in. x 48 in.

Standard Air - .075 lb/ft 3

Free Air Velocity ft/min

in. wg

St at ic P re ss ur e

D ro p m/s

Model EDD-401 resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size.

See louver selection information. (Test Figure 5.5-6.5)

The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through 0.01 oz. (3 g) of water (penetration) per sq. ft. (m²) of louver free area. *The beginning point of water penetration for Model EDD-401 is 992 fpm (5.039 m/s) free area velocity. These performance ratings do not guarantee a louver to be weatherproof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.

EDD-401

Stationary Louver, Dual Drainable Blade

Extruded Aluminum

Copyright © 2023 Greenheck Fan Corporation EDD-401, August 2023

Greenheck Fan Corporation reserves the right to make product changes without notice.

Airflow Resistance Water Penetration Standard Air - 0.075 lb/ft3 (1.2 kg/m³) Test size 48 in. x 48 in. (1219 mm x 1219 mm) Test duration of 15 min.

Standard Air - 0.075 lb/ft3 (1.2 kg/m³) Test size 48 in. x 48 in. (1219 mm x 1219 mm)

File details come from the government source that posted it. Updated .