BT - Buffer Tank Cutsheet.pdf

PDF 306 KB Posted

Attached to
Design Bid Build (DBB) Construction Requirement for Alburg Springs Land Port of Entry (LPOE), Alburg, Vermont
Solicitation number
47PB5126R0008
Issued by
Not on record

About this file

This is a product submittal data sheet for "BTH" Flanged Vertical Storage Tanks with High Connections manufactured by Taco, Inc. The document provides detailed specifications, dimensions, and options for a complete line of carbon steel pressure vessels designed and constructed per ASME Code Section VIII Division 1. All tanks feature a maximum design pressure and temperature rating of 125 psi @ 375°F, exterior red oxide primer finish, flanged inlet and outlet system connections, and are registered with the National Board of Pressure Vessel Manufacturers. The product line includes 26 tank models ranging from 50 gallons to 3,000 gallons in capacity, with corresponding dimensional specifications and approximate weights varying from 190 lbs to 6,140 lbs.

The submittal (No. 401-188, effective August 30, 2023) documents available system connection sizes by tank capacity, with flanged connections conforming to CL. 150 ANSI RFSO standards. Optional configurations available through factory consultation include alternative materials of construction, higher design pressures and temperatures, optional connection types such as 'T' female NPT threaded connections for select models (BTH0050 through BTH0350), thermal insulation options (½" Armaflex for chilled water or 1" silicon blanket for heating water), 150 PSI working pressure upgrade, and anchor clips. All tanks include standard features such as 2" NPT drain and vent connections, internal baffles, lifting lugs for models 30" diameter or greater, and inspection openings or manholes depending on tank diameter. Taco, Inc. is located in Cranston, Rhode Island, with a Canadian subsidiary in Milton, Ontario.

View the file

Other files

File Type Posted
27. Amendment 47PB5126R0008 0008 2026 07 13.pdf PDF
3. Agreement Rev 2 2026 06 18.pdf PDF
25. Amendment 47PB5126R0008 0007 2026 06 18.pdf PDF
6. WD VT20250027 2026 05 18.pdf PDF
1. Solicitation Rev 1_2026 06 11.pdf PDF
2. SF1442 Rev 1 dated 2026 06 15.pdf PDF
3. Agreement Rev 1 2026 06 12.pdf PDF
21. Amendment 47PB5126R0008 0006 2026 06 15.pdf PDF
20. Amendment 47PB5126R0008 0005 2026 06 02.pdf PDF
19. Amendment 47PB5126R0008 0004 2026 05 29.pdf PDF
16. Alburg Springs - Port Signage SOW-ASR 01.pdf PDF
15. Amendment 47PB5126R0008 0003 2026 05 21.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes_Rev 1 Amendment 0002_ 2026 05 15.pdf PDF
14. Amendment 47PB5126R0008 0002 2026 05 15.pdf PDF
13. Amendment 47PB5126R0008 0001 2026 05 12.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes 2026 05 06.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes 2026 05 06.pdf PDF
Alburg Springs LPOE Conference-Site Visit meeting minutes 2026 05 06.pdf PDF
RP - Vertical Radiant Panel Cutsheet.pdf PDF
RG - Return Grille Cutsheet.pdf PDF
SG - Supply Grille Cutsheet.pdf PDF
ET - Expansion Tank Cutsheet.pdf PDF
FT - Fin Tube Cutsheet.pdf PDF
GFT - Glycol Feed Tank Cutsheet.pdf PDF
FB - Filter Box Cutsheet.pdf PDF
PUH - Propeller Unit Heater Cutsheet.pdf PDF
GI and GR - Gravity Intake and Relief Cutsheet.pdf PDF
DH - Duct Mounted Humidifier Cutsheet.pdf PDF
SG and EG - Security Grille Cutsheet.pdf PDF
BSF - Booth Supply Fan Cut Sheet.pdf PDF
RP - Horizontal Radiant Panel Cutsheet.pdf PDF
AS - Air Separator Cutsheet.pdf PDF
EHC - Electric Heating Coil Cutsheet.pdf PDF
2026-02-06 Review of Proposed Renovations - Historic Context (1).pdf PDF
4. GSA527-21a 2026 04 15.pdf PDF
FCU - Fan Coil Unit Cutsheet.pdf PDF
6. WD VT20250027 2026 04 15.pdf PDF
CP and GP - Pump Cutsheets.pdf PDF
3. Agreement 2026 04 15.pdf PDF
EH - Electric Wall Heater Cutsheet.pdf PDF
7. PBS PPQ 2026 04 15.pdf PDF
GSHP - Ground Source Heat Pump Cutsheet.pdf PDF
L - Louver Cutsheet.pdf PDF
HP and CU - Heat Pump Mini-Split Cutsheet.pdf PDF
8. Tips on Preparing a Subcontracting Plan 2026 04 15.pdf PDF
HUM - Steam Humidifier Cutsheet.pdf PDF
Alburg Springs VT LPOE Code Report - 20260206 (1).pdf PDF
9. Model Subcontracting Plan 2026 04 15.docx DOCX document
5. Proprietary Information Agreement 2026 04 15.docx DOCX document
EF - Exhaust Fan Cutsheet.pdf PDF
Show 40 more

Latest 50 of 56 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRODUCT DATA

ITEM NO. LOCATION

MODEL NO.

GALLONS

QUANTITY

JOB:

ENGINEER:

REPRESENTATIVE:

CONTRACTOR:

“BTH” Flanged Vertical Storage Tanks with High Connections Submittal Data

Submittal No: 401-188 | Effective: August 30, 2023 | Supersedes: June 1, 2016

SPECIFICATIONS

• Designed and constructed per ASME

Code Section VIII Div. 1

• Construction: Carbon Steel with exterior red oxide primer finish

• Maximum Design Pressure and

Temperature: 125 psi @ 375°F

• Flanged inlet and outlet System

Connections (standard sizes shown)

• Registered with the National Board of

Pressure Vessel Manufacturers

Taco, Inc., 1160 Cranston Street, Cranston, RI 02920 | Tel: (401) 942-8000 | Taco (Canada), Ltd., 8450 Lawson Road, Suite #3, Milton, Ontario L9T 0J8 | Tel: (905) 564-9422 Visit our website: www.TacoComfort.com | ©2023 Taco, Inc.

SIZES & DIMENSIONS

All dimensions shown are subject to change and should not be used for prepiping.

Contact your local Taco representative should certified dimensional drawings be required.

OPTIONS (Consult Factory)

•Optional materials of construction
•Higher design pressures and

temperatures

• Optional System Connection sizes available

• Thermal insulation

□ None
□ Chilled Water ½" Armaflex
□ Heating Water 1" Silicon Blanket
•Optional Connection Types
□ ’T’ Female NPT Threaded 2” &

2 1/2” only Available only on sizes, BTH0050 thru BTH0350

•□ 150 PSI Working Pressure
•□ Anchor Clips (4)

** Add 2" to "C" dimension when specifying 10" or 12" nozzles.

MODEL NUMBER

*Complete Model Number as shown below:

BTH0050F02-125NN

TANK VOLUME A DIAMETER B C** D E DIAMETER F G APPROX.

WEIGHT

GAL. INCH INCH INCH INCH INCH INCH SIZE LBS.

BTH0050F -125NN 50 20 43 30 11 1/2 16 6 3/4 2, 3, 4 190

BTH0075F -125NN 75 24 46 34 12 5/8 20 6 3/4 2, 3, 4 240

BTH0100F -125NN 100 24 61 34 12 5/8 20 6 3/4 2, 3, 4 280

BTH0125F -125NN 125 24 76 34 12 5/8 20 6 3/4 2, 3, 4 330

BTH0150F -125NN 150 30 60 40 14 1/4 24 8 2, 3, 4 510

BTH0180F -125NN 180 30 71 40 14 1/4 24 8 2, 3, 4 590

BTH0200F -125NN 200 30 78 40 14 1/4 24 8 2, 3, 4 630

BTH0250F -125NN 250 36 69 46 16 1/4 30 7 7/8 3, 4, 6 710

BTH0300F -125NN 300 36 82 46 16 1/4 30 7 7/8 3, 4, 6 820

BTH0350F -125NN 350 36 94 46 16 1/4 30 7 7/8 3, 4, 6 910

BTH0400F -125NN 400 48 65 58 18 7/8 40 8 5/8 4, 6, 8 1,010

BTH0450F -125NN 450 48 72 58 18 7/8 40 8 5/8 4, 6, 8 1,080

BTH0500F -125NN 500 48 79 58 18 7/8 40 8 5/8 4, 6, 8 1,160

BTH0700F -125NN 700 48 100 58 18 7/8 40 8 5/8 4, 6, 8 1,300

BTH0850F -125NN 850 54 99 64 22 5/8 44 9 3/8 4, 6, 8 1,880

BTH1050F -125NN 1,050 60 99 70 24 3/4 50 9 3/4 6, 8, 10 2,130

BTH1250F -125NN 1,250 60 115 7/8 70 25 11/16 50 10 6, 8, 10, 12 2,235

BTH1500F -125NN 1,500 60 137 7/8 70 25 11/16 50 10 6, 8, 10, 12 2,740

BTH1750F -125NN 1,750 72 113 1/4 82 28 3/8 64 14 1/16 6, 8, 10, 12 3,340

BTH2000F -125NN 2,000 72 128 1/4 82 28 3/8 64 14 1/16 6, 8, 10, 12 3,640

BTH2500F -125NN 2,500 84 123 1/2 94 32 72 14 1/8 6, 8, 10, 12 5,340

BTH3000F__-125N 3,000 84 145 1/2 94 32 72 14 1/8 6, 8, 10, 12 6,140

A C

B

F E

TOP

VIEW

BASE RING

2” NPT DRAIN

2” NPT VENT

‘G’ FLANGED SYSTEM

CONNECTIONS

CL. 150 ANSI RFSO

(2 REQUIRED)

INTERNAL

BAFFLE

NOTCHED

ABOVE

DRAIN

2 LIFTING LUGS

(30” DIA. OR GREATER)

FOR LIFTING EMPTY

VESSELS ONLY INSULATION

OPTIONS

SERIAL

NUMBER

HERE

ASME

NAMEPLATE

D

OPTIONAL

ANCHOR CLIPS (X4)

250, 300, 350150, 180, 20075, 100, 125

27 3/82” T

2-1/2” T

33 3/8 39 3/823 3/8

23 5/8 C dim

Dia.

Size

27 5/8

33 5/8 39 5/8

30 36

5” INSPECTION OPENING

PROVIDED ON MODELS

48” & 54” DIAMETER.

12” X 16” MANWAY

PROVIDED FOR MODELS 60”

DIAMETER AND LARGER.

Nozzle Size offered circles below Example: 3

job:
engineer:
representative:
contractor:
item_no:
location:
gpm:
model_no:
quantity: