This is a product submittal document for the DriSteem RTS Humidifier RX Series, an electric resistive steam humidifier designed for commercial and industrial building environments. The document provides comprehensive technical specifications, dimensions, weights, electrical requirements, and installation guidance for the product line.
The RTS RX Series includes models ranging from 6 lbs/hr to 324 lbs/hr steam capacity across single-stage, two-stage, three-stage, and four-stage configurations. Electrical specifications are provided for multiple voltage options including 120V, 208V, 240V, 277V, 380V, 480V, and 600V in both single-phase and three-phase configurations, with power requirements ranging from 2 kW to 108 kW depending on model selection. All units operate at 50/60 Hz and feature a standard 5kA Short Circuit Current Rating with optional 100kA rating available. The humidifier uses resistive heating elements to boil water into steam, automatically determines drain rates based on water quality, and includes integrated drain water tempering as standard. Indoor and outdoor enclosure options are available, with detailed dimensional specifications provided for both configurations. For space distribution, two Space Distribution Unit (SDU) models are offered: the SDU-I-RX with 30 lbs/hr capacity and the SDU-E-RX with 126 lbs/hr capacity, both with specific rise, spread, and throw distance requirements to prevent condensation on surrounding surfaces depending on ambient relative humidity conditions.
View the file
Other files
Show 40 more
Latest 50 of 56 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 1 OF 16REV. 07/25
RTS® Humidifier RX Series
ELECTRIC RESISTIVE HUMIDIFIER
From providing comfort humidity to meeting the strictest clean-room requirements, the RTS electric humidifier is designed to meet the humidification demands of any building environment. The RTS humidifier RX series is an electric humidifier that uses resistive heating elements to boil water into steam. While RO/DI water will grant you the best accuracy with the RTS, any water type can be used. Drain rates are automatically determined per the quality of your water, and integrated drain water tempering is standard on every unit.
FIGURE 1-1: RTS HUMIDIFIER
OM-8040
Water level control
Steam outlet
Fill valve
P-trap
Skimmer
Heaters
Vapor-logic controller touchscreen display
Drain valve
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 2 OF 16REV. 07/25
Models, capacities, and electrical specifications
Table 2-1:
RTS humidifier capacities, electrical specifications
RTS
model
Maximum steam capacity Power Stages
Total max current draw (amps)
Single-phase Three-phase lbs/hr kg/h kW Contactors 120V 208V 240V 277V 480V 600V 208V 240V 380V 480V 600V
RX-6-1 6 2.7 2 1 16.7 9.6 8.3 21.7 4.2 3.3 — — — — —
RX-12-1 12 5.4 4 1 33.3 19.2 16.7 21.7 8.3 6.7 16.7 14.4 9.10 7.2 5.8
RX-18-1 18 8.2 6 1 — 28.9 25 21.7 12.5 10 16.7 14.4 9.10 7.2 5.8
RX-24-1 24 10.9 8 1 — 38.5 33.3 43.3 16.7 13.3 25 21.7 13.70 10.8 8.7
RX-30-1 30 13.6 10 1 — — 41.7 43.3 20.8 16.7 33.3 28.9 18.20 14.4 11.6
RX-36-1 36 16.3 12 1 — — — 43.3 25 20 33.3 28.9 18.20 14.4 11.6
RX-42-1 42 19.0 14 1 — — — — 29.2 23.3 41.6 36.1 22.80 18 14.4
RX-48-1 48 21.8 16 1 — — — — 33.3 26.7 — 43.3 27.40 21.7 17.3
RX-63-1 63 28.6 21 1 — — — — 43.8 35 — — 34.2 27.1 21.7
RX-75-1 75 34.0 25 1 — — — — — 45 — — 41 32.5 26
RX-30-2 30 13.6 10 2 — 57.7 — — — — — — — — —
RX-36-2 36 16.3 12 2 — 57.7 50 — — — — — — — —
RX-48-2 48 21.8 16 2 — 76.9 66.7 86.6 — — 50 — — — —
RX-63-2 63 28.6 21 2 — — 91.7 86.6 — — 66.6 57.7 — — —
RX-75-2 75 34.0 25 2 — — — — 54.2 — 83.2 72.2 — — —
RX-90-2 90 40.8 30 2 — — — — 62.5 50 — 86.6 54.7 43.3 34.6
RX-102-2 102 46.3 34 2 — — — — 70.8 56.7 — 86.6 54.7 43.3 34.6
RX-126-2 126 57.1 42 2 — — — — 87.5 70 — — 68.4 54.1 43.3
RX-144-2 144 65.3 48 2 — — — — — 80 — — 82 65 52
RX-162-2 162 73.5 54 2 — — — — — 90 — — 82 65 52
| • | All RTS humidifier models operate at 50/60 Hz. |
| • | For wire sizing, the highest leg draw is shown due to current imbalance. |
| • | See Table 70-1 for heaters. |
| • | Maximum amps is determined based on the heaters used by each model. Some voltage/kW combinations show higher amperage values than |
what the unit capacity will allow.
• The standard Short Circuit Current Rating (SCCR) for the RTS humidifier is 5kA. A 100kA rating is available as an option.
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 3 OF 16REV. 07/25
Models, capacities, and electrical specifications (continued)
Table 3-1:
RTS humidifier capacities, electrical specifications (continued)
RTS model
Maximum steam capacity Power Stages
Total max current draw (amps)
Single-phase Three-phase lbs/hr kg/h kW Contactors 120V 208V 240V 277V 480V 600V 208V 240V 380V 480V 600V
RX-63-3 63 28.6 21 3 — 115.4 — — — — — — — — —
RX-75-3 75 34.0 25 3 — 129.8 112.5 130 — — — — — — —
RX-90-3 90 40.8 30 3 — — 125 130 — — 99.9 — — — —
RX-102-3 102 46.3 34 3 — — — 130 — — 99.9 — — — —
RX-126-3 126 57.1 42 3 — — — — — — 124.9 108.3 — — —
RX-144-3 144 65.3 48 3 — — — — 100 — — 129.9 — — —
RX-162-3 162 73.5 54 3 — — — — 112.5 — — 129.9 — — —
RX-189-3 189 85.7 63 3 — — — — 137.5 110 — — 102.6 81.2 65
RX-216-3 216 98.0 72 3 — — — — — 120 — — 123.1 97.4 77.9
RX-243-3 243 110.2 81 3 — — — — — 135 — — 123.1 97.4 77.9
RX-102-4 102 46.3 34 4 — 173.1 150 — — — — — — — —
RX-126-4 126 57.1 42 4 — — 183.3 173.3 — — — — — — —
RX-144-4 144 65.3 48 4 — — — 173.3 — — 133.2 — — — —
RX-162-4 162 73.5 54 4 — — — — — — 166.5 — — — —
RX-216-4 216 98.0 72 4 — — — — 150 — — 173.2 — — —
RX-264-4 264 119.7 88 4 — — — — 183.3 146.7 — — 164.1 129.9 103.9
RX-288-4 288 130.6 96 4 — — — — — 160 — — 164.1 129.9 103.9
RX-324-4 324 146.9 108 4 — — — — — 180 — — 164.1 129.9 103.9
| • | All RTS humidifier models operate at 50/60 Hz. |
| • | For wire sizing, the highest leg draw is shown due to current imbalance. |
| • | See Table 70-1 for heaters. |
| • | Maximum amps is determined based on the heaters used by each model. Some voltage/kW combinations show higher amperage values than |
what the unit capacity will allow.
• The standard Short Circuit Current Rating (SCCR) for the RTS humidifier is 5kA. A 100kA rating is available as an option.
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 4 OF 16REV. 07/25
Indoor and no enclosure dimensions (RX-XX-1 and RX-XX-2)
OM-8076
Top view
Back viewFront view
Bottom view
M Door access
Electrical knockout
Touch screen
Steam outlet
Mounting holes (4)
E
C
A Q
R
B
D
Probe
K
F H
LN
J & G
0.75” (DN 20) NPT/BSP fill 1” (DN25) NPT/BSP drain
FIGURE 4-1: RTS HUMIDIFIER DIMENSIONS
See Table 5-1 for dimension.
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 5 OF 16REV. 07/25
Indoor and no enclosure dimensions (RX-XX-1 and RX-XX-2)
Table 5-1:
Indoor unit dimensions
Description
RX-XX-1 RX-XX-2
inches mm inches mm
A Overall length 24.8 629 26.1 663
B Overall width 16.4 416 21.0 533
C Overall height 24.9 632 31.4 798
D Steam outlet
11.3 286 11.9 301
E 2.8 70 3.3 83
F Supply water
1.6 41 3.0 76
G 2.6 66 1.6 41
H Drain water
4.0 102 3.0 76
J 2.6 66 4.0 102
K Electrical knockout (Control)
8.8 224 2.8 71
L 9.1 231 10.1 256
M Electrical knockout (Power)
2.8 71 8.8 224
N 9.6 244 9.4 239
Q Mounting holes
16.0 406 16.0 406
R 21.3 541 28.0 711
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 6 OF 16REV. 07/25
Indoor and no enclosure dimensions (RX-XX-3 and RX-XX-4)
FIGURE 6-1: RTS HUMIDIFIER DIMENSIONS
Table 6-1:
Indoor unit dimensions
Description
RX-XX-3 & RX-XX-4
inches mm
A Overall length 37.4 950
B Overall width 21.6 549
C Overall height 41.3 1049
D Steam outlet
5.3 135
E 5.9 150
F Supply water
5.7 145
G 4.3 109
H Drain water
4.7 119
J 7.2 183
K Electrical knockout
8.3 211
L 4.2 107
M Steam outlet (flange connection only) 3.5 89
OM-8077
Top view
Back viewFront view
L
Touch screen keypad
Steam outlet E
C
A
B
D
Fill
H
G
K
Side view
Door access
F
J
Electrical knockout
Drain
Probe
M
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 7 OF 16REV. 07/25
Weights:RX-XX-1 and RX-XX-2
Table 7-1:
RTS humidifier (RX-XX-1 and RX-XX-2) weights
RTS
model
Indoor Enclosure Outdoor Enclosure No Enclosure
Dry Weight* (Empty) Operating Weight Dry Weight*
(Empty) Operating Weight Dry Weight* (Empty) Operating Weight lbs kg lbs kg lbs kg lbs kg lbs kg lbs kg
RX-6-1 92.9 42.2 137.1 62.3 357.7 162.6 401.5 182.5 91.3 41.5 135.5 61.6
RX-12-1 94.1 42.8 138.3 62.9 358.5 163.0 402.7 183.0 92.5 42.0 136.7 62.1
RX-18-1 95.3 43.3 139.5 63.4 359.7 163.5 403.9 183.6 93.7 42.6 137.9 62.7
RX-24-1 95.3 43.3 139.5 63.4 359.7 163.5 403.9 183.6 93.7 42.6 137.9 62.7
RX-30-1 95.3 43.3 139.5 63.4 359.7 163.5 403.9 183.6 93.7 42.6 137.9 62.7
RX-36-1 95.3 43.3 139.5 63.4 359.7 163.5 403.9 183.6 93.7 42.6 137.9 62.7
RX-42-1 95.7 43.5 139.9 63.6 360.1 163.7 404.3 183.8 94.1 42.8 138.3 62.9
RX-48-1 96.1 43.7 140.3 63.8 360.5 163.9 404.7 184.0 94.5 43.0 138.7 63.0
RX-63-1 97.0 44.1 141.2 64.2 361.4 164.3 405.6 184.4 95.4 43.4 139.6 63.5
RX-75-1 98.0 44.5 142.2 64.6 362.4 164.7 406.6 184.8 96.4 43.8 140.6 63.9
RX-30-2 132.6 60.3 246.9 112.2 397.6 180.7 511.9 232.7 131.6 59.8 245.9 111.8
RX-36-2 132.6 60.3 246.9 112.2 397.6 180.7 511.9 232.7 131.6 59.8 245.9 111.8
RX-48-2 136.6 62.1 250.9 114.0 401.6 182.5 515.9 234.5 135.6 61.6 249.9 113.6
RX-63-2 136.6 62.1 250.9 114.0 401.6 182.5 515.9 234.5 135.6 61.6 249.9 113.6
RX-75-2 140.6 63.9 254.9 115.8 405.6 184.4 519.9 236.3 139.6 63.5 253.9 115.4
RX-90-2 138.2 62.8 252.5 114.8 403.2 183.3 517.5 235.2 137.2 62.4 251.5 114.3
RX-102-2 139.0 63.2 253.3 115.1 404.0 183.6 518.3 235.6 138.0 62.7 252.3 114.7
RX-126-2 140.0 63.6 254.3 115.6 405.0 184.1 519.3 236.0 139.0 63.2 253.3 115.1
RX-144-2 141.0 64.1 255.3 116.0 406.0 184.5 520.3 236.5 140.0 63.6 254.3 115.6
RX-162-2 142.0 64.5 256.3 116.5 407.0 185.0 521.3 236.9 141.0 64.1 255.3 116.0
* Add approximately 46 lbs (21 kg) for packaging material for shipping weight.
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 8 OF 16REV. 07/25
Weights: RX-XX-3 and RX-XX-4
Table 8-1:
RTS humidifier (RX-XX-3 and RX-XX-4) weights
RTS model
Indoor Enclosure Outdoor Enclosure No Enclosure
Dry Weight* Operating Weight Dry Weight* Operating Weight Dry Weight* Operating Weight lbs kg lbs kg lbs kg lbs kg lbs kg lbs kg
RX-63-3 193.5 88.0 450.4 204.7 476.3 216.5 733.1 333.2 166.0 75.5 422.9 192.2
RX-75-3 192.6 87.5 449.5 204.3 475.4 216.1 732.2 332.8 165.1 75.0 422.0 191.8
RX-90-3 197.1 89.6 454.0 206.4 479.9 218.1 736.7 334.9 169.6 77.1 426.5 193.9
RX-102-3 197.1 89.6 454.0 206.4 479.9 218.1 736.7 334.9 169.6 77.1 426.5 193.9
RX-126-3 198.3 90.1 455.2 206.9 481.1 218.7 737.9 335.4 170.8 77.6 427.7 194.4
RX-144-3 199.5 90.7 456.4 207.4 482.3 219.2 739.1 336.0 172.0 78.2 428.9 194.9
RX-162-3 200.7 91.2 457.6 208.0 483.5 219.8 740.3 336.5 173.2 78.7 430.1 195.5
RX-189-3 202.5 92.0 459.4 208.8 485.3 220.6 741.8 337.2 175.0 79.5 431.9 196.3
RX-216-3 203.7 92.6 460.6 209.4 486.5 221.1 743.3 337.9 176.2 80.1 433.1 196.9
RX-243-3 205.2 93.3 462.1 210.0 488.0 221.8 744.8 338.6 177.7 80.8 434.6 197.5
RX-102-4 196.2 89.2 453.1 205.9 479.0 217.7 735.8 334.5 168.7 76.7 425.6 193.4
RX-126-4 201.0 91.4 457.9 208.1 483.8 219.9 740.6 336.6 173.5 78.9 430.4 195.6
RX-144-4 202.2 91.9 459.1 208.7 483.4 219.7 741.8 337.2 174.7 79.4 431.6 196.2
RX-162-4 203.8 92.6 460.7 209.4 486.6 221.2 743.4 337.9 176.3 80.1 433.2 196.9
RX-216-4 207.0 94.1 463.9 210.9 489.8 222.6 746.6 339.4 179.5 81.6 436.4 198.4
RX-264-4 209.4 95.2 466.3 211.9 492.2 223.7 749.0 340.5 181.9 82.7 438.8 199.4
RX-288-4 211.0 95.9 467.9 212.7 493.8 224.4 750.6 341.2 183.5 83.4 440.4 200.2
RX-324-4 213.0 96.8 469.9 213.6 495.8 225.3 752.6 342.1 185.5 84.3 442.4 201.1
* Add approximately 46 lbs (21 kg) for packaging material for shipping weight.
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 9 OF 16REV. 07/25
Location and clearance recommendations (Indoor and no enclosure)
FIGURE 9-1: RX SERIES CLEARANCE RECOMMENDATIONS FOR -1 AND -2 MODELS (INDOOR AND NO ENCLOSURE UNITS)
Top: 12"(305 mm)
Right side:
6" (152 mm)*
Supporting wall
Front electrical controls:
36" (915 mm)
Floor: 12"(305 mm) Plumbing connections
Left side: 2" (51 mm)
Secured to supporting wall
To dispersion assembly
OM-8041
Maintain these clearances for service and maintenance.
* � If there is more space available, increase the clearance on this side of the unit. Infrequent access may be required to the hoses behind the electrical cabinet.
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 10 OF 16REV. 07/25
Location and clearance recommendations (Indoor and no enclosure)
Table 10-1:
Floor stand weights and height (for indoor enclosures)
Part number Unit size
Weight configuration Height
Assembled Shipping inches mm lbs kg lbs kg
600935 -2 stage 26.8 12.2 30.8 14.0
19.25 489
600670 -3 & -4 stage 35.1 16.0 41.1 18.7
FIGURE 10-1: RX SERIES CLEARANCE RECOMMENDATIONS FOR -3 AND -4 MODELS (INDOOR AND NO ENCLOSURE UNITS)
Top: 12"(305 mm)
Right side:
24" (610 mm) Plumbing connections
Front:
36" (915 mm) Electrical controls
Left side: 2" (51 mm)
To dispersion assembly
OM-8078
Maintain these clearances for service and maintenance.
Back side: 2" (51 mm)
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 11 OF 16REV. 07/25
Outdoor enclosure: Dimensions
Table 11-1:
Outdoor unit amps (all models)
Full Load Amps (Heater Package)
Full Load Amps (No Heater Package)
120V 60 Hz
230V 50Hz
120V 60Hz
230V 50Hz
7.0 3.7 0.3 0.2
Table 11-1:
Outdoor enclosure dimensions
Description RX-XX-1 RX-XX-2 RX-XX-3 and RX-XX-4 inches mm inches mm inches mm
A Overall length 53.6 1361 53.6 1361 62.8 1595
B Overall width 32.8 833 32.8 833 32.8 833
C Overall height 62.0 1575 62.0 1575 62.0 1575
D Steam outlet (external)
55.0 1397 55.0 1397 55.0 1397
E 19.5 495 18.9 480 11.1 282
F Steam outlet (internal)
5.6 142 6.1 155 8.6 218
G 6.7 170 6.7 170 6.2 157
H Pipe chase position
4.4 112 4.4 112 4.4 112
J 4.4 112 4.4 112 4.4 112
K Pipe chase dimensions
14.0 356 14.0 356 14.0 356
L 7.0 178 7.0 178 7.0 178
FIGURE 11-1: OUTDOOR ENCLOSURE DIMENSIONS
OM-8093
E
G
K
H
F
B
J
Exit for steam outlet (through pipe chase)
Pipe chase
Ventilation fan
Heater
Control cabinet
RTS
humidifier
Ventilation fan
Access panel door
Exit for steam outlet
Airflow
Airflow
Access panel door
L
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 12 OF 16REV. 07/25
Outdoor enclosure: Clearances
Top: 6" (152 mm)
Right side electrical controls:
30" (76 mm)
Front 36" (915 mm)
• External steam outlet:
(16" (406 mm)
• Internal steam outlet:
(6" (152 mm)
Left side: 6" (152 mm)
OM-8097
FIGURE 12-1: RTS SERIES CLEARANCE RECOMMENDATIONS
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 13 OF 16REV. 07/25
3/8" typical clearance
Unit base Weather stripping Wood nailer (by installer)Insulation and cant (by installer)
B D
A C
1"x 2" (25 mm x 50 mm) wood nailer
3" (76 mm) typical
Cross section view
DM-7496
Table 13-1:
Outdoor enclosure curb dimensions
Outdoor enclosure model A B C D inches mm inches mm inches mm inches mm
RX-XX-1 and RX-XX-2 47.63 1209.8 45.48 1155.2 26.73 678.9 24.73 628.1
RX-XX-3 and RX-XX-4 56.73 1440.9 54.58 1386.3 26.73 678.9 24.73 628.1
Outdoor enclosure curb details and dimensions
FIGURE 13-1: RX SERIES OUTDOOR ENCLOSURE CURB DETAILS AND DIMENSIONS
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 14 OF 16REV. 07/25
RTS Humidifier: Dispersion
INSTALLING SPACE DISTRIBUTION UNITS (SDU)
Provide at least 6" (150 mm) clearance on each side of the SDU.
Field wiring is required to connect the SDU fan and airflow proving switch terminals to RTS electrical panel terminals. Refer to the external connections diagram in the package shipped with your unit.
Important: Maximum ambient RH must not exceed 45% for the SDU-I to operate properly.
Table 14-1:
SDU specifications
SDU model Maximum capacity Shipping weight Amps at
120V (50/60 Hz)
Horsepower cfm m3/s dB* lbs/hr kg/h lbs kg
SDU-I-RX 30 13.6 67 30.4 3.20 1/5 760 0.36 58
SDU-E-RX 126 57 61 27.7 2.07 1/8 545 0.26 64
* Measurement taken 6.5' (2 m) in front of SDU cabinet.
RX-XX-3 and RX-XX-4 models cannot be used with an SDU.
SDU's ship separate from the RX humidifier.
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 15 OF 16REV. 07/25
FIGURE 15-1: SDU-I-RX MECHANICAL DETAIL
Front view Side view
OM-8110
FIGURE 15-2: SDU-E-RX MECHANICAL DETAIL
Front view Side view
OM-8111
Back view
Back view
BA
FD
16.0" (406.4 mm)
Air intake vent
E
Humidifier air discharge vent Mounting holes (2)
3.13” (80 mm)
A
F D
16.0" (406.4 mm)
3.13” (80 mm)
Mounting holes (2)
B
Steam outlet
C
Table 15-1:
SDU dimension
SDU model A B C D E F in mm in mm in mm in mm in mm in mm
SDU-I-RX 24.7 627 16.0 406 17.9 455 11.4 290 2.8 70 Ø1.5 Ø38
SDU-E-RX 24.7 627 16.0 406 16.1 409 11.4 290 2.8 70 Ø1.5
or Ø2*
Ø38 or Ø51*
* 1.5" (38 mm) or 2" (51 mm) up to 75 lbs/hr. 2" (51 mm) only greater than 75 lbs/hr.
C
E
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 16 OF 16REV. 07/25
As steam is discharged from the SDU-E, it quickly cools and turns to a visible fog that is lighter than air. As this fog is carried away from the SDU-E by the airstream, it tends to rise toward the ceiling. If this fog contacts solid surfaces (columns, beams, ceiling, pipes, etc.) before it disappears, it could collect and drip as water. The greater the space relative humidity, the more the fog will rise, throw and spread.
Table 16-1 lists the minimum rise, throw and spread non-wetting distances for SDU-E at 40%, 50% and 60% RH in the space. Surfaces cooler than ambient temperature, or objects located within this minimum dimension, can cause condensation and dripping. To avoid steam impingement on surrounding areas, observe the minimum non-wetting distances in Table 16-1.
The SDU-E contains a blower (120 V, single-phase, 60 Hz) and an airflow proving switch (field-wired to the humidifier electrical panel). A wiring diagram of the SDU-E is included with the unit.
On a call for humidity, the humidifier begins producing steam, and the start relay energizes the SDU-E blower. When the call for humidity is satisfied, the Vapor-logic controller keeps the blower running to disperse residual moisture using a time delay.
Steam outlet
Throw
Air intake grille
OM-8114
Rise
FIGURE 16-1: SDU-E RISE, SPREAD, AND
THROW
Spread
DRISTEEM RTS HUMIDIFIER SUBMITTAL • PAGE 17 OF 16REV. 07/25
Table 17-1:
SDU-E-RX minimum nonwetting distances kW of
RTS
Maximum steam capacity
40% RH @ 70 °F (21 °C) 50% RH @ 70 °F (21 °C) 60% RH @ 70 °F (21 °C)
Rise Spread Throw Rise Spread Throw Rise Spread Throw lbs/hr kg/h ft m ft m ft m ft m ft m ft m ft m ft m ft m
2 6 2.7 1.0 0.3 1.0 0.3 5.0 1.5 1.5 0.5 1.5 0.5 6.5 2.0 2.5 0.8 2.5 0.8 7.5 2.3
4 12 5.4 1.0 0.3 1.0 0.3 5.0 1.5 1.5 0.5 1.5 0.5 6.5 2.0 2.5 0.8 2.5 0.8 7.5 2.3
6 18 8.2 1.0 0.3 1.0 0.3 5.0 1.5 1.5 0.5 1.5 0.5 6.5 2.0 2.5 0.8 2.5 0.8 7.5 2.3
8 24 10.9 1.0 0.3 1.0 0.3 5.5 1.7 1.5 0.5 1.5 0.5 6.5 2.0 2.5 0.8 2.5 0.8 7.5 2.3
10 30 13.6 1.5 0.5 1.5 0.5 6.0 1.8 2.0 0.6 2.0 0.6 7.0 2.1 3.0 1.0 3.0 1.0 8.0 2.5
12 36 16.3 1.5 0.5 1.5 0.5 6.0 1.8 2.0 0.6 2.0 0.6 7.0 2.1 3.0 1.0 3.0 1.0 8.0 2.5
14 42 19.1 2.0 0.6 2.0 0.6 7.0 2.1 2.0 0.6 2.0 0.6 7.0 2.1 3.0 1.0 3.0 1.0 9.0 2.7
16 48 21.8 2.0 0.6 2.0 0.6 7.0 2.1 2.0 0.6 2.0 0.6 7.0 2.1 3.0 1.0 3.0 1.0 9.0 2.7
21 63 28.6 2.0 0.6 2.0 0.6 7.5 2.3 2.5 0.8 2.5 0.8 10.0 3.0 3.0 1.0 3.0 1.0 12.0 3.7
25 75 34.0 2.0 0.6 2.0 0.6 8.0 2.5 2.5 0.8 2.5 0.8 10.5 3.2 3.5 1.1 3.5 1.1 12.5 3.8
30 90 40.9 2.0 0.6 2.0 0.6 8.0 2.5 2.5 0.8 2.5 0.8 10.5 3.2 3.5 1.1 3.5 1.1 12.5 3.8
34 102 46.3 2.0 0.6 2.0 0.6 8.0 2.5 2.5 0.8 2.5 0.8 10.5 3.2 3.5 1.1 3.5 1.1 12.5 3.8
42 126 57.1 2.5 0.6 2.5 0.6 8.5 2.5 3.0 0.8 3.0 0.8 11 3.2 4.0 1.1 4.0 1.1 13 3.8
Notes:
• Surfaces or objects directly in the path of steam discharge may cause condensation and dripping.
• To avoid steam impingement on surrounding areas, observe the minimum nonwetting dimensions in this table.
• Rise: The minimum nonwetting height above the steam outlet of the SDU-E-RX.
• Spread: The minimum nonwetting width from the steam outlet of the SDU-E-RX. Spread dimensions greater than 3 ft (1 m) may require additional side clearance.
• Throw: The minimum nonwetting horizontal distance from the steam outlet of the SDU-E-RX.
File details come from the government source that posted it. Updated .