FT - Fin Tube Cutsheet.pdf
PDF 210 KB Posted
- Solicitation number
- 47PB5126R0008
- Issued by
- Not on record
About this file
This is a submittal specification document for the LC-210 Light Commercial Slope Top Enclosure manufactured by Vulcan Radiator. The specification details a heating element enclosure system designed for commercial applications with both single-tier and two-tier configurations.
The LC-210 enclosure features a slope-louvered, pencil-proof outlet design available in lengths from 2'0" to 8'0" in 6-inch increments. Standard material is 18-gauge cold-rolled steel with optional 16-gauge available; finish options include baked powder (standard) or baked metallic. The system includes overlapping-type accessories with pre-punched fastening holes and offers optional air seal (1/8" x 3/8" closed-cell), brackets constructed from 14-gauge galvannealed steel, and backplate options (partial or full height) in 20-gauge or optional 18-gauge galvannealed material. Two element types are specified: copper/aluminum (mechanically expanded, 2'0" to 8'0" in 1-inch increments with standard one-end flare) and IPS steel (mechanically expanded, 2'0" to 12'0" in 1-inch increments with standard NPT threaded ends or optional beveled ends for field welding). Rating tables provide BTU/hour output across multiple configurations, element sizes (¾" to 1¼" tubes), and operating temperatures from 150°F to 215°F steam, with approved ratings for both single and dual-tier elements centered at 3½" mounting height.
View the file
Other files
Show 40 more
Latest 50 of 56 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT: DATE:
LOCATION:
ARCHITECT:
ENGINEER:
CONTRACTOR:
PO NUMBER:
260 North Elm St., Westfield, MA 01085
(413) 568-9571 Fax: (413) 564-5661 www.vulcanrad.com
Style “LC-210” Light Commercial Slope Top Enclosure Copper/Aluminum & Steel Ratings
LC-210
Submittal
Specification
LC-210
1-TIER
LC-210
2-TIER
Dimensions are in inches. Dimensions in parentheses are in millimeters.
9/2017
CAT NO. A MIN. A MAX.
VR02 5-15/16 (150.8) 8-7/16 (214.3)
VR03 6-1/6 (154) 8-5/8 (219.1)
VR04 6-9/16 (166.7) 8-15/16 (227)
VR05 6-9/16 (166.7) 9-1/8 (231.8)
VR06
7-1/8 (181) 8-11/16 (220.7)
VR07
VR08 6-11/16 (169.9) 9-1/4 (235)
VR09
7-3/16 (182.6) 8-11/16 (220.7)
VR10
VR11 6-11/16 (169.9) 9-3/16 (233.4)
VR12
7-3/16 (182.6) 8-11/16 (220.7)
VR13
ENCLOSURE:
| STYLE : | LC-210 |
| OUTLET: | Slope Louvered |
| Pencil Proof | |
| LENGTHS: | 2'0" thru 8'0" in 6" Increments |
| MAT’L | 18 Ga. CRS (Std) |
| 16 Ga. CRS (Opt’l) | |
| FINISH: | Baked Powder (Std) |
| Baked Metallic (Opt’l) |
ACCESSORIES:
Overlapping Type All accessories return to the wall at the bottom and have pre-punched holes for fastening to the wall.
BACKPLATE:
| TYPE: | Partial Backplate B-610 |
| LENGTHS: | 8'0" Only |
| MATERIAL: | 20 Ga. Galvannealed (Std) |
| 18 Ga. Galvannealed (Opt’l) |
| TYPE: | Full Ht. B/P (Opt’l) |
| LENGTHS: | 2'0" thru 8'0" in 6" Increments |
| MATERIAL: | 20 Ga. Galvannealed (Std) |
| 18 Ga. Galvannealed (Opt’l) |
AIR SEAL: 1/8" x 3/8" Closed Cell (Opt’l)
| BRACKETS: | 14 Ga. Galvannealed Steel | |
| One Piece Brkt |
ELEMENT:
| TYPE: | Cu/AL (Mechanically Expanded) |
| LENGTHS: | 2'0'' thru 8'0'' in 1'' Increments. |
| One End Flared (Std) |
| TYPE: | IPS Steel (Mechanically |
| Expanded) | |
| LENGTHS: | 2'0" thru 12'0" in 1'' Increments. |
| NPT Thread both Ends (Std) | |
| Beveled Ends for Field Weld | |
| (Opt’l) |
| See Catalog for Working |
| Pressures. |
RATINGS LC-210
STEEL ELEMENT STEAM
215°
FACTOR
1.00
HOT WATER (AVG.)
200° 190° 180° 170° 160° 150°
I.P.S.
SIZE
CATALOG
DESIGNATION
FIN SIZE
IN INCHES FIN/FT
FIN
THICKNESS
MTG. HEIGHT
IN INCHES
FACTOR
0.86 0.78 0.69 0.61 0.53 0.45
1" VR11 2 ¾ x 3 ¾ 40 0.024 14 ¼ 910 785 710 630 555 485 410 1" VR12 2 ¾ x 5 40 0.024 14 ¼ 910 785 710 630 555 485 410
1 ¼" VR13 2 ¾ x 5 40 0.024 14 ¼ 930 800 725 625 570 495 420
COPPER/ALUMINUM ELEMENT STEAM
215°
FACTOR
1.00
HOT WATER (AVG.)
200° 190° 180° 170° 160° 150°
TUBE
SIZE
CATALOG
DESIGNATION
FIN SIZE
IN INCHES FIN/FT
FIN
THICKNESS
MTG. HEIGHT
IN INCHES
FACTOR
0.86 0.78 0.69 0.61 0.53 0.45
¾" VR02 2 ¾ x 2 ½ 60 0.010 14 ¼ 1140 980 890 785 695 605 515 ¾" VR04 2 ¾ x 3 ¾ 50 0.011 14 ¼ 1170 1010 915 810 715 620 530 1" VR03 2 ¾ x 2 ½ 55 0.011 14 ¼ 1090 935 850 755 665 575 490 1" VR05 2 ¾ x 3 ¾ 50 0.011 14 ¼ 1130 979 880 780 690 600 510 1" VR06 2 ¾ x 5 40 0.020 14 ¼ 1200 1030 935 830 730 630 540 1" VR07 2 ¾ x 5 50 0.020 14 ¼ 1210 1040 945 835 740 645 545
1 ¼" VR08 2 ¾ x 3 ¾ 50 0.020 14 ¼ 1150 990 895 795 700 610 515 1 ¼" VR09 2 ¾ x 5 40 0.020 14 ¼ 1150 990 895 795 700 610 515 1 ¼" VR10 2 ¾ x 5 50 0.020 14 ¼ 1230 1060 960 850 750 655 555
APPROVED RATINGS*
RATING BTU/H WITH (2) TIER ELEMENT 3½" CENTERED
COPPER/ALUMINUM ELEMENT STEAM
215°
FACTOR
1.00
HOT WATER (AVG.)
200° 190° 180° 170° 160° 150°
TUBE
SIZE
CATALOG
DESIGNATION
FIN SIZE
IN INCHES FIN/FT
FIN
THICKNESS
MTG. HEIGHT
IN INCHES
FACTOR
0.86 0.78 0.69 0.61 0.53 0.45
¾" VR02 2 ¾ x 2 ½ 60 0.011 14 ¼ 1560 1340 1215 1075 950 825 700 1" VR03 2 ¾ x 2 ½ 55 0.011 14 ¼ 1600 1375 1250 1105 975 845 720
Bold, italicized units are rated
| Check Box5: Off |
| Check Box9: Off |
| Check Box10: Off |
| Check Box11: Off |
| Check Box1: Off |
| Check Box6: Off |
| Check Box2: Off |
| Check Box12: Off |
| Check Box3: Off |
| Check Box4: Off |
| Check Box7: Off |
| Check Box13: Off |
| Check Box8: Off |
| Check Box14: Off |
| Check Box16: Off |
| Check Box17: Off |
| PROJECT: |
| DATE: |
| LOCATION: |
| ARCHITECT: |
| ENGINEER: |
| CONTRACTOR: |
| PO NUMBER: |
File details come from the government source that posted it. Updated .