About this file

This document is a Tekla Structures elevation drawing for the Carmel Fire Training project, drawn on 10/10/2025 with revision A issued for approval on 10/13/2025. The detailed architectural elevation blueprint shows a multi-story building with five distinct floor levels, ranging from ground floor to 5th floor, with precise measurements and structural details. The elevation drawing includes specific architectural elements such as doors, structural steel sections (HSS4X2X1/8), pipe specifications (PIPE1-1/4SCH40), and precise height measurements for each floor level, with total building height reaching 47'-6".

The technical drawing provides comprehensive structural information including continuous outer and inner measurements, door placements, and floor-to-floor heights. Specific architectural components are annotated with codes like FR6, HMD5, and GR6, indicating different structural or architectural elements. The drawing uses a grid system for precise positioning and includes detailed dimensional notations for each floor, showing meticulous planning for the fire training facility's architectural and structural design.

View the file

Other files

File Type Posted
CFD_Training_Facility_Project.pdf PDF
ERECTION_DRAWING_E19.pdf PDF
ERECTION_DRAWING_E4.pdf PDF
ERECTION_DRAWING_E8.pdf PDF
ERECTION_DRAWING_E1.pdf PDF
ERECTION_DRAWING_E10.pdf PDF
ERECTION_DRAWING_E11.pdf PDF
ERECTION_DRAWING_E15.pdf PDF
ERECTION_DRAWING_E17.pdf PDF
ERECTION_DRAWING_E20.pdf PDF
ERECTION_DRAWING_E5.pdf PDF
ERECTION_DRAWING_E7.pdf PDF
ERECTION_DRAWING_E12.pdf PDF
ERECTION_DRAWING_E14.pdf PDF
ERECTION_DRAWING_E16.pdf PDF
ERECTION_DRAWING_E18.pdf PDF
ERECTION_DRAWING_E2.pdf PDF
ERECTION_DRAWING_E3.pdf PDF
ERECTION_DRAWING_E6.pdf PDF
ERECTION_DRAWING_E13.pdf PDF
CFD_CTC_Close_Up.png PNG image
CFD_CTC_Training_Tower_Location.png PNG image
CFD_CTC_Whole_Parcel-1.png PNG image
6._Comprehensive_Set_of_Technical_Specifications_2021-04-28_(V2.7).docx DOCX document
MAINTENANCE_BOND.pdf PDF
NON_COLLUSION_AFFIDAVIT.pdf PDF
REQUEST_FOR_PROPOSAL_CHANGE.pdf PDF
RIGHT_OF_ENTRY.pdf PDF
CONTRACT_CHANGE_ORDER.pdf PDF
CONTRACT_CHANGE_REQUEST.pdf PDF
Exhibit_D_E-Verify-1.PDF PDF
FIELD_ORDER.pdf PDF
PERFORMANCE_BOND.pdf PDF
SAMPLE_OF_MOU_FOR_E-VERIFY.pdf PDF
MANUFACTURERS_LIST.pdf PDF
PAYMENT_BOND.pdf PDF
SAMPLE_AGREEMENT.pdf PDF
SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf PDF
SUBCONTRACTORS_LIST.pdf PDF
WORK_DIRECTIVE_CHANGE.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10/13/2025A ISSUED FOR APPROVAL

REV DESCRIPTION DATE

Te kl a st ru ct ur es

DESCRIPTION

PROJECT NAME

DRAWN BY

DATE DRAWN

JOB No. DRG No.

ELEVATION

CARMEL FIRE TRAINING

ABC

10/10/2025 - E9

3 - 3 E1

EL.+9'-6"

EL.+28'-6"

EL.+19'-0"

EL.+38'-0"

EL.+0"

EL.+47'-6"

CONT. OUTER TO OUTER CONT. OUTER TO OUTER

CONT. OUTER TO OUTER

CONT. OUTER TO OUTER

CONT. INNER TO INNER

CONT. OUTER TO OUTER

CONT. OUTER TO OUTERCONT. OUTER TO OUTERCONT. OUTER TO OUTERCONT. OUTER TO OUTER

CONT. INNER TO INNER

9' -6

FR6

HSS4X2X18/

DOOR

18'-0

FR6

HSS4X2X18/

HMD6

HSS4X2X18/

7' -0

8'-0

DOOR

HMD5

HSS4X2X18/

DOOR

HMD5

HSS4X2X18/

DOOR

3'-0

HMD6

HSS4X2X18/

16'-812/

14'-1014/

3' -6

9' -6

'-6

2' -2

40'-0

DOOR

GR19

PIPE1-14/ SCH40

2ND FLOOR

7' -0

22'-1034/

4TH FLOOR

HMD5

HSS4X2X18/

FR6

HSS4X2X18/

212/

DOOR

FR6

HSS4X2X18/

DOOR

3'-0

16'-812/

3'-0

212/

40'-0

8'-0

7' -0

312/

8'-634/

DOOR

3'-0

7' -0

HMD5

HSS4X2X18/

3RD FLOOR

FR6

HSS4X2X18/

39'-5

9'

-6

5TH FLOOR

6'-0

312/

FR6

HSS4X2X18/

DOOR

DOOR

DOOR

DOOR

DOOR

DOOR

GR6

PIPE1-14/ SCH40

FR2

HSS4X2X18/

HMD1

HSS4X2X18/

1ST FLOOR

GROUND FL

8'-0

1'-134/3'-0

3'-0

7' -0

3' -6

9' -6

9' -6

8' -1

4 22

8'-08'-08'-08'-0

2' -2

7' -0

1014/29'-1014/2'-812/

7'-8

2' -2

7' -0

2'

-2

2' -2

2' -2

8'-0

1'-1112/

312/ 2312/

File details come from the government source that posted it. Updated .