ERECTION_DRAWING_E2.pdf

PDF 114 KB Posted

Attached to
CFD Training Facility Project
Solicitation number
IFB-2025-037
Issued by
Hamilton County, Indiana

About this file

The document is a Tekla Structures architectural drawing for the Carmel Fire Training facility's 1st floor plan view, dated 02/18/2022. The detailed technical drawing includes precise measurements and structural annotations for a building layout, featuring multiple grid lines, structural elements like C10X15.3 and C4X5.4 channel sections, pipe specifications (such as PIPE1-1/4SCH40), and various plate (PL) elements. The drawing provides a comprehensive grid-based floor plan with specific dimensional notations, indicating a detailed engineering design for a fire training facility.

The drawing does not contain specific pricing, funding, or contract terms. Instead, it represents a technical architectural blueprint focusing on structural configurations, spatial relationships, and precise measurements for the first floor of the Carmel Fire Training building. Annotations like "V.I.F." (Verify In Field) and "ALL DETAILS & DIMENSION VERIFY IN FIELD" suggest this is a design document intended for construction planning and execution, with an emphasis on on-site verification of the detailed specifications provided.

View the file

Other files

File Type Posted
CFD_Training_Facility_Project.pdf PDF
ERECTION_DRAWING_E19.pdf PDF
ERECTION_DRAWING_E4.pdf PDF
ERECTION_DRAWING_E8.pdf PDF
ERECTION_DRAWING_E1.pdf PDF
ERECTION_DRAWING_E10.pdf PDF
ERECTION_DRAWING_E11.pdf PDF
ERECTION_DRAWING_E15.pdf PDF
ERECTION_DRAWING_E17.pdf PDF
ERECTION_DRAWING_E20.pdf PDF
ERECTION_DRAWING_E5.pdf PDF
ERECTION_DRAWING_E7.pdf PDF
ERECTION_DRAWING_E12.pdf PDF
ERECTION_DRAWING_E14.pdf PDF
ERECTION_DRAWING_E16.pdf PDF
ERECTION_DRAWING_E18.pdf PDF
ERECTION_DRAWING_E3.pdf PDF
ERECTION_DRAWING_E6.pdf PDF
ERECTION_DRAWING_E9.pdf PDF
ERECTION_DRAWING_E13.pdf PDF
CFD_CTC_Close_Up.png PNG image
CFD_CTC_Training_Tower_Location.png PNG image
CFD_CTC_Whole_Parcel-1.png PNG image
6._Comprehensive_Set_of_Technical_Specifications_2021-04-28_(V2.7).docx DOCX document
MAINTENANCE_BOND.pdf PDF
NON_COLLUSION_AFFIDAVIT.pdf PDF
REQUEST_FOR_PROPOSAL_CHANGE.pdf PDF
RIGHT_OF_ENTRY.pdf PDF
CONTRACT_CHANGE_ORDER.pdf PDF
CONTRACT_CHANGE_REQUEST.pdf PDF
Exhibit_D_E-Verify-1.PDF PDF
FIELD_ORDER.pdf PDF
PERFORMANCE_BOND.pdf PDF
SAMPLE_OF_MOU_FOR_E-VERIFY.pdf PDF
MANUFACTURERS_LIST.pdf PDF
PAYMENT_BOND.pdf PDF
SAMPLE_AGREEMENT.pdf PDF
SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf PDF
SUBCONTRACTORS_LIST.pdf PDF
WORK_DIRECTIVE_CHANGE.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Te kl a st ru ct ur es

10/13/2025A ISSUED FOR APPROVAL

09/17/2025A ISSUED FOR APPROVAL

REV DESCRIPTION DATE

DESCRIPTION

PROJECT NAME

DRAWN BY

DATE DRAWN

JOB No. DRG No.

1st FLOOR PLAN VIEW

CARMEL FIRE TRAINING

ABC

02/18/2022 - E2

1st FLOOR PLAN VIEW

CONT. OUTER TO OUTER

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNER

CONT. OUTER TO OUTER CONT. OUTER TO OUTER CONT. OUTER TO OUTER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. OUTER TO OUTER

CONT. OUTER TO OUTER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

IN

N

ER

T

O

IN

N

ER

V.I.F.

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNER

C

O N

T.

IN

N

ER

T O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNER CONT. INNER TO INNER CONT. INNER TO INNER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

IN

N

ER

T

O

IN

N

ER

ALL DETAILS & DIMENSION VERIFY IN FILD

NOTE:-

ST1

C10X15.3

8/

40'-0

8' -0

CH3

C4X5.4

'-7

9 16/

2/

39'-5

G R

PI

PE

1-

1 4/

SC

H

4'-014/2 2316/

EP1

PL38/ "X7

7'-7316/

2/

7'-7316/

1' -1

16/

212/

1' -0

2516/

2516/

6'-434/1'-11

CH1

C4X5.4

8'-0 8'-0

4'-014/

8'-0

GR14

PIPE1-14/ SCH40

EP1

PL38/ "X7

312/

G R

PI

PE

1-

1 4/

SC

H

'-0

1'-11

7' -8

GR11

PIPE1-14/ SCH40

8' -0

8' -0

GR11

PIPE1-14/ SCH40

2' -8

4' -0

8'-0

212/

20'-0

GR14

PIPE1-14/ SCH80

8' -0

EP1

PL38/ "X7

8' -0

'-5

2'-1058/ 418/

2' -8

EP1

PL38/ "X7

21'-634/

8' -0

9' -5

1 2/

'-0

O

PE

N

IN

G

19'-412/

ST1

C10X15.3

7' -8

GR12

PIPE1-14/ SCH40

'-5

2/

14'-134/

GR4

PIPE1-14/ SCH40

GR3

PIPE1-14/ SCH40

7'-8

GR7

PIPE1-14/ SCH40

G R

PI

PE

1-

1 4/

SC

H

40 ST1

C10X15.3

CH3

C4X5.4

2516/

4/

3' -3

1 4/

5'-614/

1 4/

8/

7'-8 7'-8

312/

7' -8

7' -8

7' -8

7' -8

41316/

3'-5716/2