ERECTION_DRAWING_E10.pdf
PDF 81 KB Posted
- Attached to
- CFD Training Facility Project
- Solicitation number
- IFB-2025-037
- Issued by
- Hamilton County, Indiana
About this file
This document is a structural elevation drawing for the Carmel Fire Training facility, created using Tekla Structures software and issued for approval on 10/13/2025. The detailed architectural drawing depicts a multi-story building with precise measurements and floor elevations ranging from ground level (EL. +0") to the top floor at EL. +47'-6". The drawing includes specific technical details such as window placements, structural elements like HSS4X2X1/8 framing, pipe specifications (1-1/4 SCH40), and precise dimensional measurements for each floor level.
The elevation drawing provides a comprehensive vertical cross-section view of the building, showing consistent window placements, structural grid lines, and floor-to-floor heights. The drawing uses a standardized drafting approach with notations for various structural components, splice locations, and elevation markers. The project appears to be a purpose-built fire training facility with a systematic architectural design that allows for uniform floor layouts and structured spatial planning across multiple levels.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Te kl a st ru ct ur es
10/13/2025A ISSUED FOR APPROVAL
REV DESCRIPTION DATE
DESCRIPTION
PROJECT NAME
DRAWN BY
DATE DRAWN
JOB No. DRG No.
ELEVATION
CARMEL FIRE TRAINING
ABC
10/10/2025 - E10
4 - 4 E1
EL.+28'-6"
EL.+9'-6"
EL.+0"
EL.+19'-0"
EL.+38'-0"
EL.+47'-6"
CONT. OUTER TO OUTER CONT. OUTER TO OUTER
V.I.F.
CONT. OUTER TO OUTERCONT. OUTER TO OUTERCONT. OUTER TO OUTER
V.I.F.
V.I.F.
V.I.F.
V.I.F.
8'-0
8' -1
3' -2
WINDOW
2'-6
3' -2
2'-6
8'-0
WINDOW
2' -1
9' -6
4' -0
2'-6
WINDOW
2' -4
8'-512/
9' -6
2' -4
L OF SPLICE
4' -0
FR4
HSS4X2X18/
WINDOW
8'-512/
1ST FLOOR
8'-0
9' -6
WINDOW
2'-7
512/
FR4
HSS4X2X18/
GROUND FL
FR4
HSS4X2X18/
WINDOW
FR4
HSS4X2X18/
2516/
1' -0
2'-6
4' -0
212/
FR4
HSS4X2X18/
2'-7
2'-72'-6
FR4
HSS4X2X18/
2'-7
2' -4
FR4
HSS4X2X18/
2'-7
WINDOW
2' -4
PIPE1-14/ SCH40
2'-6
3' -2
WINDOW
2' -4
5TH FLOOR
63'-7
40'-0
FR4
HSS4X2X18/
12'-512/
C
1'-0WINDOW
WINDOW
9' -6
FR4
HSS4X2X18/
L OF SPLICE
2'-62'-6
212/
FR4
HSS4X2X18/
11'-034/
512/
WINDOW
WINDOW WINDOW
4TH FLOOR
WINDOW
1 2/
WINDOW WINDOW
C
FR4
HSS4X2X18/
FR4
HSS4X2X18/
FR4
HSS4X2X18/
FR4
HSS4X2X18/
FR4
HSS4X2X18/
FR4
HSS4X2X18/
GR4
PIPE1-14/ SCH40
PL38/ "X4
PIPE1-14/ SCH40
PIPE1-14/ SCH40
PIPE1-14/ SCH40
3RD FLOOR
2ND FLOOR
212/
1'-0 1'-0
7'-7316/
3' -6
5' -0
1 4/ 7'
-0
8'-08'-08'-0
9' -6
4' -0
'-6
2 312/2 2312/
8'-040'-08'-0
2'-92'-62'-7512/2'-7 2'-68'-512/ 2'
-4 4'
-0 3'
-2
4' -0
2' -4
4' -0
3' -2
8'-512/ 2'-9
3' -2
4' -0
2' -4
3' -2
4' -0
2' -48'-512/512/2'-7
312/
2'-7
2' -4
4' -0
3' -2
2'-7
4 2'-68'-512/
2' -4
4' -0
3' -2
2'-6512/
2' -4
4' -0
3' -2
3' -2
8'-512/ 2'-6 2'-7
3' -2
2'-62'-6
4' -0
2' -1
2' -4
4' -0
17'-634/
312/
12'-434/ 312/
File details come from the government source that posted it. Updated .