ERECTION_DRAWING_E5.pdf
PDF 94 KB Posted
- Attached to
- CFD Training Facility Project
- Solicitation number
- IFB-2025-037
- Issued by
- Hamilton County, Indiana
About this file
This document is a 4th floor plan view architectural drawing for the Carmel Fire Training facility, created using Tekla Structures software and issued for approval on 10/13/2025. The technical drawing provides a detailed structural layout with precise measurements, grid references, and structural elements including various pipe specifications (1-1/4 SCH40), steel channel sections (CH1, CH3), and plate elements (EP1).
The drawing includes multiple grid references and continuous measurement annotations, indicating "CONT. INNER TO INNER" and "CONT. OUTER TO OUTER" markings throughout the plan. Specific dimensional details are noted, such as 64'-0" total length, 40'-0" width sections, and various smaller measurements ranging from 7'-8" to 12'-4". A critical notation reads "ALL DETAILS & DIMENSION VERIFY IN FIELD" suggesting that on-site verification will be required during the construction phase. The plan appears to be part of a larger architectural and structural design set for a fire training facility, with the drawing labeled as revision E5 and dated 09/16/2025.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Te kl a st ru ct ur es
10/13/2025A ISSUED FOR APPROVAL
REV DESCRIPTION DATE
DESCRIPTION
PROJECT NAME
DRAWN BY
DATE DRAWN
JOB No. DRG No.
4th FLOOR PLAN VIEW
CARMEL FIRE TRAINING
ABC
09/16/2025 - E5
4th FLOOR PLAN VIEW
CONT. INNER TO INNER
V.I.F.
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
O U
TE
R
T O
O U
TE
R
V.
I.F
CONT. INNER TO INNER
C
O N
T.
IN
N
ER
T O
IN
N
ER
CONT. INNER TO INNER
CONT. OUTER TO OUTER
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
IN
N
ER
T
O
IN
N
ER
CONT. OUTER TO OUTER
CONT. INNER TO INNERCONT. INNER TO INNER
CONT. OUTER TO OUTERCONT. OUTER TO OUTERCONT. OUTER TO OUTER
V.I.F. V.I.F.
ALL DETAILS & DIMENSION VERIFY IN FILD
NOTE:-
19'-412/
812/
4' -2
12'-434/
GR12
PIPE1-14/ SCH40
2/
64'-0
GR11
PIPE1-14/ SCH40
2312/
8' -0
7' -8
3' -3
1 4/
'-5
7' -8
8' -0
7' -7
1 2/
C H
C
4X 5.
7'-8
'-5 7'-8
2/
EP1
PL38/ "X7
CH3
C4X5.4
8'-0
ST1
C10X15.3
8' -0
8' -0
'-0
7' -8
7' -8
EP1
PL38/ "X7
14'-134/4
'-0
GR14
PIPE1-14/ SCH40
8' -0
312/
CH3
C4X5.4
EP1
PL38/ "X7
EP1
PL38/ "X7
GR11
PIPE1-14/ SCH40
ST1
C10X15.3
GR14
PIPE1-14/ SCH40
GR13
PIPE1-14/ SCH40
4/
812/ 812/
8' -0 7' -8
7' -8
'-0
2/
20'-0
2/ 2 2 2312/ 2
39'-57'-8
8'-040'-08'-0
312/
12'-434/ 11'-212/ 312/2 312/
312/5'-234/
File details come from the government source that posted it. Updated .