ERECTION_DRAWING_E15.pdf

PDF 142 KB Posted

Attached to
CFD Training Facility Project
Solicitation number
IFB-2025-037
Issued by
Hamilton County, Indiana

About this file

The document is a detailed architectural drawing (Stair Plan) for the Carmel Fire Training project, created using Tekla Structures software and issued for approval on 10/13/2025. The drawing provides a comprehensive technical schematic for a multi-story staircase, with precise measurements and elevation details ranging from ground level (EL. +0") to EL. +47'-6". The plan includes multiple floor levels (1st through 5th floors), with specific annotations for structural components such as channels (CH1, CH3), steel sections, pipes, and plate elements (EP1).

The technical drawing includes intricate details of stair dimensions, including riser heights, tread depths, nosing specifications, and structural members. Key components are labeled with specific material designations like C4X5.4 channels, C10X15.3 steel sections, and PIPE1-1/4 SCH40 pipes. The plan shows consistent stair width of 9'-6" across different levels, with varying elevation markers and structural connections. The drawing is meticulously drafted to provide comprehensive construction guidance for the staircase, including precise measurements, material specifications, and structural integration across multiple floors of the fire training facility.

View the file

Other files

File Type Posted
CFD_Training_Facility_Project.pdf PDF
ERECTION_DRAWING_E13.pdf PDF
ERECTION_DRAWING_E19.pdf PDF
ERECTION_DRAWING_E4.pdf PDF
ERECTION_DRAWING_E8.pdf PDF
ERECTION_DRAWING_E1.pdf PDF
ERECTION_DRAWING_E10.pdf PDF
ERECTION_DRAWING_E11.pdf PDF
ERECTION_DRAWING_E17.pdf PDF
ERECTION_DRAWING_E20.pdf PDF
ERECTION_DRAWING_E5.pdf PDF
ERECTION_DRAWING_E7.pdf PDF
ERECTION_DRAWING_E12.pdf PDF
ERECTION_DRAWING_E14.pdf PDF
ERECTION_DRAWING_E16.pdf PDF
ERECTION_DRAWING_E18.pdf PDF
ERECTION_DRAWING_E2.pdf PDF
ERECTION_DRAWING_E3.pdf PDF
ERECTION_DRAWING_E6.pdf PDF
ERECTION_DRAWING_E9.pdf PDF
CFD_CTC_Close_Up.png PNG image
CFD_CTC_Training_Tower_Location.png PNG image
CFD_CTC_Whole_Parcel-1.png PNG image
MANUFACTURERS_LIST.pdf PDF
PAYMENT_BOND.pdf PDF
SAMPLE_AGREEMENT.pdf PDF
SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf PDF
SUBCONTRACTORS_LIST.pdf PDF
WORK_DIRECTIVE_CHANGE.pdf PDF
6._Comprehensive_Set_of_Technical_Specifications_2021-04-28_(V2.7).docx DOCX document
MAINTENANCE_BOND.pdf PDF
NON_COLLUSION_AFFIDAVIT.pdf PDF
REQUEST_FOR_PROPOSAL_CHANGE.pdf PDF
RIGHT_OF_ENTRY.pdf PDF
CONTRACT_CHANGE_ORDER.pdf PDF
CONTRACT_CHANGE_REQUEST.pdf PDF
Exhibit_D_E-Verify-1.PDF PDF
FIELD_ORDER.pdf PDF
PERFORMANCE_BOND.pdf PDF
SAMPLE_OF_MOU_FOR_E-VERIFY.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10/13/2025A ISSUED FOR APPROVAL

REV DESCRIPTION DATE

Te kl a st ru ct ur es

DESCRIPTION

PROJECT NAME

DRAWN BY

DATE DRAWN

JOB No. DRG No.

STAIR PLAN

CARMEL FIRE TRAINING

ABC

10/10/2025 - E15

14 - 14

DETAIL 2

E1

EL.+19'-0"

EL.+0"

EL.+28'-6"

EL.+38'-0"

EL.+9'-6"

EL.+47'-6"

CONT. INNER TO INNER

TYP

TY

P

TY

P

TYP

TY

P

TYP

CONT. OUTER TO OUTER

9' -6

DET. 9

E19

CH3

C4X5.4

GROUND FL.

3'-

TRADE

1018/

W.P.

CH1

C4X5.4

3' -0

CH3

C4X5.4

R

IS

ER

15@6=7'-6

W.P.

5'-7

8/ =

9' -6

3'-

3 16/

1018/ 9'

-6

GR11

PIPE1-14/ SCH40

ST1

C10X15.3

2'-

3 16/

3' -6

TRADE

CH1

C4X5.4

W.P.

1'-634/

19'-412/

3' -6

2'-

3 16/

GR17

PIPE1-14/ SCH40

8/ =

9' -6

DET. 11

E19

4'-

16/

3'-

3 16/

1 1 2/

GR14

PIPE1-14/ SCH40

DET. 10

E19

GR14

PIPE1-14/ SCH40

1 1 2/

8/ =

9' -6

9' -6

EP1

PL38/ "X7

3' -6

NOSING

NOSING

4'-5

CH1

C4X5.4

R

IS

ER

NOSING

R

IS

ER

EP1

PL38/ "X7

TRADE

2'-112/

8/

EP1

PL38/ "X7

CH1

C4X5.4

EP1

PL38/ "X7

9' -6

CH1

C4X5.4

9' -6

EP1

PL38/ "X7

CH3

C4X5.4

EP1

PL38/ "X7

3'-

EP1

PL38/ "X7

EP1

PL38/ "X7

ST1

C10X15.3

GR14

PIPE1-14/ SCH40

GR11

PIPE1-14/ SCH80

1ST FLOOR

2ND FLOOR

3RD FLOOR

4TH FLOOR

5TH FLOOR

3' -0

3' -6

2'-534/

1' -9

1' -9

1 1 2/

8/

2'-534/

1' -9

1' -9

2'-112/

5'-234/

4'-

16/

8/

15@6=7'-6

4'-5

9' -6

3' -6

1018/

8/

1' -9

1' -9

2'-

3 16/

4'-

16/

8/

15@6=7'-6

'-6

3'

-6

3' -0

5'-234/

1'-634/

1'-634/

9' -6

9' -6

8/

3'-

3 16/

3'-

4'-59'-412/

20'-0

312/

8/

CH3

C4X5.4

CH1

C4X5.4

8'-11

2' -8

8' -0

1 4/

5'-7

5'-234/

3' -3

1 4/

16/

ST1

C10X15.3

312/

GR14

PIPE1-14/ SCH40

E17

E17

4' -0

4/

GR14

PIPE1-14/ SCH40

1 4/

E16

E16

E16

E16

CH3

C4X5.4

E17

E17

ST1

C10X15.3

GR15

PIPE1-14/ SCH40

CH3

C4X5.4

GR11

PIPE1-14/ SCH40

5'-234/

3' -5

16/

2' -8

8/

2' -1

8/

4/

File details come from the government source that posted it. Updated .