This document is a Tekla Structures architectural drawing for the 3rd Floor Plan View of the Carmel Fire Training facility, drawn on 06/21/2022. The plan view provides a detailed schematic of the building's third floor, showing precise measurements, structural elements, and grid lines. Specific architectural components include various structural steel sections like C4X5.4, C7X9.8, and C10X15.3, as well as plate (PL) and pipe (PIPE1-1/4SCH40) elements. The drawing includes multiple annotations for continuity markers such as "CONT. OUTER TO OUTER" and "CONT. INNER TO INNER", and includes a note "V.I.F. - ALL DETAILS & DIMENSION VERIFY IN FIELD", indicating the importance of field verification.
The drawing is marked with revision dates of 10/13/2025 and 09/17/2025, suggesting ongoing design refinement. Dimensional annotations reveal precise measurements including various section lengths ranging from 1'-8" to 64'-0", with multiple grid references and structural element placements. The plan view appears to be part of a comprehensive architectural design process for the Carmel Fire Training facility, providing a detailed blueprint for construction or renovation purposes. The drawing number is E4, and it was created by someone identified as "ABC" on the document.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Te kl a st ru ct ur es
10/13/2025A ISSUED FOR APPROVAL
09/17/2025A ISSUED FOR APPROVAL
REV DESCRIPTION DATE
DESCRIPTION
PROJECT NAME
DRAWN BY
DATE DRAWN
JOB No. DRG No.
3rd FLOOR PLAN VIEW
CARMEL FIRE TRAINING
ABC
06/21/2022 - E4
3rd FLOOR PLAN VIEW
CONT. OUTER TO OUTER
C O
N T.
O U
TE
R
T O
O U
TE
R
CONT. INNER TO INNERCONT. INNER TO INNER
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
IN
N
ER
T
O
IN
N
ER
CONT. OUTER TO OUTER
CONT. INNER TO INNER
CONT. INNER TO INNER
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
IN
N
ER
T
O
IN
N
ER
CONT. OUTER TO OUTER
C
O N
T.
O
U
TE
R T
O O
U
TE
R
C O
N T.
IN
N
ER
T
O
IN
N
ER
CONT. OUTER TO OUTER
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
IN
N
ER
T
O
IN
N
ER
C O
N T.
O U
TE
R
T O
O U
TE
R
C O
N T.
O U
TE
R
T O
O U
TE
R
CONT. INNER TO INNER
CONT. OUTER TO OUTER
C O
N T.
IN
N
ER
T
O
IN
N
ER
V.I.F.
ALL DETAILS & DIMENSION VERIFY IN FILD
NOTE:-
312/
558/
8'-0
8' -0
2/
39'-5
2/
EP1
PL38/ "X7
7'-8
7' -8
2/
11316/
1'-10516/
CH3
C4X5.4
'-5
2/
40'-0
GR7
PIPE1-14/ SCH40
19'-412/
EP1
PL38/ "X7
812/
64'-0
2/
2' -8
4' -3
3 16/
7'-8
7' -8
14'-534/
4' -2
3' -3
1 4/
1'-838/
16/
8' -0
'-0
7' -8
8'-0
218/
29'-3
312/
GR14
PIPE1-14/ SCH40
CH1
C4X5.4
EP1
PL38/ "X7
CH3
C4X5.4
EP1
PL38/ "X7
CH2
C7X9.8
G R
PI
PE
1-
1 4/
SC
H
ST1
C10X15.3
FL1
PL18/ "X56
5'-39'-6 5'-614/
4' -8
3' -4
4/
'-0
2/
9' -5
1 2/
2'-84'-638/
812/
112/3'-5716/
7'
-8
20'-0
8' -0 7' -8
8' -0
8' -0
7' -8
'-0
8' -0
7'-8
8'-0
312/2
'-5
3@1'-1012/ =5'-7716/
11'-034/
8/
2' -8
1 4/
8/
File details come from the government source that posted it. Updated .