ERECTION_DRAWING_E4.pdf

PDF 90 KB Posted

Attached to
CFD Training Facility Project
Solicitation number
IFB-2025-037
Issued by
Hamilton County, Indiana

About this file

This document is a Tekla Structures architectural drawing for the 3rd Floor Plan View of the Carmel Fire Training facility, drawn on 06/21/2022. The plan view provides a detailed schematic of the building's third floor, showing precise measurements, structural elements, and grid lines. Specific architectural components include various structural steel sections like C4X5.4, C7X9.8, and C10X15.3, as well as plate (PL) and pipe (PIPE1-1/4SCH40) elements. The drawing includes multiple annotations for continuity markers such as "CONT. OUTER TO OUTER" and "CONT. INNER TO INNER", and includes a note "V.I.F. - ALL DETAILS & DIMENSION VERIFY IN FIELD", indicating the importance of field verification.

The drawing is marked with revision dates of 10/13/2025 and 09/17/2025, suggesting ongoing design refinement. Dimensional annotations reveal precise measurements including various section lengths ranging from 1'-8" to 64'-0", with multiple grid references and structural element placements. The plan view appears to be part of a comprehensive architectural design process for the Carmel Fire Training facility, providing a detailed blueprint for construction or renovation purposes. The drawing number is E4, and it was created by someone identified as "ABC" on the document.

View the file

Other files

File Type Posted
CFD_Training_Facility_Project.pdf PDF
ERECTION_DRAWING_E1.pdf PDF
ERECTION_DRAWING_E10.pdf PDF
ERECTION_DRAWING_E11.pdf PDF
ERECTION_DRAWING_E15.pdf PDF
ERECTION_DRAWING_E17.pdf PDF
ERECTION_DRAWING_E20.pdf PDF
ERECTION_DRAWING_E5.pdf PDF
ERECTION_DRAWING_E7.pdf PDF
ERECTION_DRAWING_E19.pdf PDF
ERECTION_DRAWING_E8.pdf PDF
ERECTION_DRAWING_E12.pdf PDF
ERECTION_DRAWING_E14.pdf PDF
ERECTION_DRAWING_E16.pdf PDF
ERECTION_DRAWING_E18.pdf PDF
ERECTION_DRAWING_E2.pdf PDF
ERECTION_DRAWING_E3.pdf PDF
ERECTION_DRAWING_E6.pdf PDF
ERECTION_DRAWING_E9.pdf PDF
ERECTION_DRAWING_E13.pdf PDF
CFD_CTC_Training_Tower_Location.png PNG image
CFD_CTC_Whole_Parcel-1.png PNG image
CFD_CTC_Close_Up.png PNG image
CONTRACT_CHANGE_ORDER.pdf PDF
CONTRACT_CHANGE_REQUEST.pdf PDF
6._Comprehensive_Set_of_Technical_Specifications_2021-04-28_(V2.7).docx DOCX document
MAINTENANCE_BOND.pdf PDF
NON_COLLUSION_AFFIDAVIT.pdf PDF
REQUEST_FOR_PROPOSAL_CHANGE.pdf PDF
RIGHT_OF_ENTRY.pdf PDF
Exhibit_D_E-Verify-1.PDF PDF
FIELD_ORDER.pdf PDF
PERFORMANCE_BOND.pdf PDF
SAMPLE_OF_MOU_FOR_E-VERIFY.pdf PDF
MANUFACTURERS_LIST.pdf PDF
PAYMENT_BOND.pdf PDF
SAMPLE_AGREEMENT.pdf PDF
SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf PDF
SUBCONTRACTORS_LIST.pdf PDF
WORK_DIRECTIVE_CHANGE.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Te kl a st ru ct ur es

10/13/2025A ISSUED FOR APPROVAL

09/17/2025A ISSUED FOR APPROVAL

REV DESCRIPTION DATE

DESCRIPTION

PROJECT NAME

DRAWN BY

DATE DRAWN

JOB No. DRG No.

3rd FLOOR PLAN VIEW

CARMEL FIRE TRAINING

ABC

06/21/2022 - E4

3rd FLOOR PLAN VIEW

CONT. OUTER TO OUTER

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNERCONT. INNER TO INNER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

IN

N

ER

T

O

IN

N

ER

CONT. OUTER TO OUTER

CONT. INNER TO INNER

CONT. INNER TO INNER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

IN

N

ER

T

O

IN

N

ER

CONT. OUTER TO OUTER

C

O N

T.

O

U

TE

R T

O O

U

TE

R

C O

N T.

IN

N

ER

T

O

IN

N

ER

CONT. OUTER TO OUTER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNER

CONT. OUTER TO OUTER

C O

N T.

IN

N

ER

T

O

IN

N

ER

V.I.F.

ALL DETAILS & DIMENSION VERIFY IN FILD

NOTE:-

312/

558/

8'-0

8' -0

2/

39'-5

2/

EP1

PL38/ "X7

7'-8

7' -8

2/

11316/

1'-10516/

CH3

C4X5.4

'-5

2/

40'-0

GR7

PIPE1-14/ SCH40

19'-412/

EP1

PL38/ "X7

812/

64'-0

2/

2' -8

4' -3

3 16/

7'-8

7' -8

14'-534/

4' -2

3' -3

1 4/

1'-838/

16/

8' -0

'-0

7' -8

8'-0

218/

29'-3

312/

GR14

PIPE1-14/ SCH40

CH1

C4X5.4

EP1

PL38/ "X7

CH3

C4X5.4

EP1

PL38/ "X7

CH2

C7X9.8

G R

PI

PE

1-

1 4/

SC

H

ST1

C10X15.3

FL1

PL18/ "X56

5'-39'-6 5'-614/

4' -8

3' -4

4/

'-0

2/

9' -5

1 2/

2'-84'-638/

812/

112/3'-5716/

7'

-8

20'-0

8' -0 7' -8

8' -0

8' -0

7' -8

'-0

8' -0

7'-8

8'-0

312/2

'-5

3@1'-1012/ =5'-7716/

11'-034/

8/

2' -8

1 4/

8/

File details come from the government source that posted it. Updated .