About this file
The document is a Tekla Structures elevation drawing for the Carmel Fire Training project, issued for approval on 10/13/2025. The drawing provides a detailed cross-sectional view of a multi-story building, showing five distinct floor levels with specific architectural and structural details. The elevation drawing includes precise measurements for each floor, ranging from ground level to the top floor at EL.+47'-6", with various structural elements like doors, pipes (SCH40 and SCH80), and steel sections (HSS, C-channel) annotated throughout the design.
The drawing uses a grid system to map out the structural components, with notations for different materials and specifications at each level. The floors appear to be designed with consistent heights and similar structural approaches, suggesting a standardized construction method. The document is specifically labeled as drawing number E8, created on 10/10/2025, and is part of a set of technical drawings for what seems to be a fire training facility. The level of detail indicates this is a technical, engineering-focused document used for construction planning and architectural visualization.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Te kl a st ru ct ur es
10/13/2025A ISSUED FOR APPROVAL
REV DESCRIPTION DATE
DESCRIPTION
PROJECT NAME
DRAWN BY
DATE DRAWN
JOB No. DRG No.
ELEVATION
CARMEL FIRE TRAINING
ABC
10/10/2025 - E8
2 - 2 E1
EL.+47'-6"
EL.+19'-0"
EL.+0"
EL.+9'-6"
EL.+28'-6"
EL.+38'-0"
CONT. OUTER TO OUTER CONT. OUTER TO OUTERCONT. OUTER TO OUTER CONT. OUTER TO OUTERCONT. OUTER TO OUTER 8'-0
112/
2' -2
GR7
PIPE1-14/ SCH80
9' -6
DOOR
3'-0
212/
3' -6
1ST FLOOR
HMD5
HSS4X2X18/
9' -6
GR5
PIPE1-14/ SCH40
8'-0
DOOR
DOOR
8'-634/
8'-0
3'-0
2'-1058/
CH1
C4X5.4
558/
DOOR
8' -1
0 7'-8
312/
DOOR
HMD6
HSS4X2X18/
7' -0
GR8
PIPE1-14/ SCH40
DOOR
2' -2
FR6
HSS4X2X18/
9' -6
EP1
PL38/ "X7
HMD5
HSS4X2X18/
DOOR
41316/
8'-0
2' -2
HMD6
HSS4X2X18/
14'-1014/
8'-0
2ND FLOOR
3RD FLOOR
212/
'-6
FR6
HSS4X2X18/
GROUND FL
4TH FLOOR
8'-0
9' -6
8'-0
7' -0
29'-1014/
GR7
PIPE1-14/ SCH40
HMD5
HSS4X2X18/
GR9
PIPE1-14/ SCH40
3'-5716/
DOOR
7' -0
GR1
PIPE1-14/ SCH40
1014/
3' -6
40'-0
DOOR
5TH FLOOR
DOOR
DOOR
HMD5
HSS4X2X18/
DOOR
1'-1112/
EP1
PL38/ "X7
ST1
C4X5.4
FR6
HSS4X2X18/
FR6
HSS4X2X18/
FR6
HSS4X2X18/
FR6
HSS4X2X18/
GR18
PIPE1-14/ SCH40
8'-0
3' -6
6516/
8' -1
0 2
9' -6
212/
3' -6
3' -6
40'-0
2 312/
3'-03'-017'-812/
7' -0
7' -0
2'
-21014/3'-02'-812/
2'-8
23'-214/3'-0
2' -2
7' -0