ERECTION_DRAWING_E12.pdf

PDF 125 KB Posted

Attached to
CFD Training Facility Project
Solicitation number
IFB-2025-037
Issued by
Hamilton County, Indiana

About this file

The document is a Tekla Structures architectural elevation drawing for the Carmel Fire Training project, dated 10/13/2025. The drawing provides detailed structural specifications for a multi-story building, showing precise measurements and floor elevations from ground level to the 5th floor. The elevation plan includes specific details for structural elements such as doors, pipes (PIPE1-1/4SCH40), steel sections (HSS4X2X1/8), and various floor levels marked at different heights.

The drawing illustrates a comprehensive architectural blueprint with precise technical annotations, including continuous outer and inner measurements, verified in-field (V.I.F.) notations, and specific structural component specifications. The building appears to be a fire training facility with multiple floors, internal stairways, and strategically placed structural supports. The elevation drawing provides a technical cross-section view of the building's structural design, showing floor heights ranging from ground level (EL.+0") to the 5th floor (EL.+47'-6"), with detailed placement of structural members, doors, and other architectural elements.

View the file

Other files

File Type Posted
CFD_Training_Facility_Project.pdf PDF
ERECTION_DRAWING_E19.pdf PDF
ERECTION_DRAWING_E4.pdf PDF
ERECTION_DRAWING_E8.pdf PDF
ERECTION_DRAWING_E13.pdf PDF
ERECTION_DRAWING_E1.pdf PDF
ERECTION_DRAWING_E10.pdf PDF
ERECTION_DRAWING_E11.pdf PDF
ERECTION_DRAWING_E15.pdf PDF
ERECTION_DRAWING_E17.pdf PDF
ERECTION_DRAWING_E20.pdf PDF
ERECTION_DRAWING_E5.pdf PDF
ERECTION_DRAWING_E7.pdf PDF
ERECTION_DRAWING_E14.pdf PDF
ERECTION_DRAWING_E16.pdf PDF
ERECTION_DRAWING_E18.pdf PDF
ERECTION_DRAWING_E2.pdf PDF
ERECTION_DRAWING_E3.pdf PDF
ERECTION_DRAWING_E6.pdf PDF
ERECTION_DRAWING_E9.pdf PDF
CFD_CTC_Close_Up.png PNG image
CFD_CTC_Training_Tower_Location.png PNG image
CFD_CTC_Whole_Parcel-1.png PNG image
6._Comprehensive_Set_of_Technical_Specifications_2021-04-28_(V2.7).docx DOCX document
MAINTENANCE_BOND.pdf PDF
NON_COLLUSION_AFFIDAVIT.pdf PDF
REQUEST_FOR_PROPOSAL_CHANGE.pdf PDF
RIGHT_OF_ENTRY.pdf PDF
MANUFACTURERS_LIST.pdf PDF
PAYMENT_BOND.pdf PDF
SAMPLE_AGREEMENT.pdf PDF
SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf PDF
SUBCONTRACTORS_LIST.pdf PDF
WORK_DIRECTIVE_CHANGE.pdf PDF
CONTRACT_CHANGE_ORDER.pdf PDF
CONTRACT_CHANGE_REQUEST.pdf PDF
Exhibit_D_E-Verify-1.PDF PDF
FIELD_ORDER.pdf PDF
PERFORMANCE_BOND.pdf PDF
SAMPLE_OF_MOU_FOR_E-VERIFY.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Te kl a st ru ct ur es

10/13/2025A ISSUED FOR APPROVAL

REV DESCRIPTION DATE

DESCRIPTION

PROJECT NAME

DRAWN BY

DATE DRAWN

JOB No. DRG No.

ELEVATION

CARMEL FIRE TRAINING

ABC

10/10/2025 - E12

8 - 8 E1

7 - 7 E1

EL.+9'-6"

EL.+38'-0"

EL.+0"

EL.+19'-0"

EL.+28'-6"

EL.+47'-6"

EL.+9'-6"

EL.+38'-0"

EL.+19'-0"

EL.+28'-6"

EL.+0"

EL.+47'-6"

CONT. OUTER TO OUTERCONT. OUTER TO OUTER CONT. OUTER TO OUTER

CONT. INNER TO INNERCONT. INNER TO INNER CONT. INNER TO INNER

CONT. OUTER TO OUTER

CONT. INNER TO INNER

CONT. OUTER TO OUTER

V.I.F.

V.I.F.

CONT. OUTER TO OUTER

V.I.F. V.I.F.

CONT. INNER TO INNER

V.I.F.V.I.F.

3' -6

7' -0

DOOR

9' -6

612/

2' -2

7' -0

FR7

HSS4X2X18/

6'-0

8'-0

7' -0

8'-0

FR7

HSS4X2X18/

GR7

PIPE1-14/ SCH40

DOOR

HMD3

HSS4X2X18/

FR2

HSS4X2X18/

DOOR

FR2

HSS4X2X18/

2' -2

2ND FLOOR

GR8PIPE1- 1

4/ SCH40

8'-0

9' -6

1ST FLOOR

6'-0

7' -0

7'-512/

7' -0

3' -6

ST1C10X15.3

3'-10

DOOR

6'-0

GROUND FL

2' -2

7'-8

2' -2

DOOR

2' -2

HMD3

HSS4X2X18/

DOOR

DOOR

DOOR

4TH FLOOR

3RD FLOOR

3'-0

9'-512/

7'-8

6'-0

2' -2

7'-8

DOOR

7' -0

3' -6

8'-0

2'-8

6'-412/

9' -6

212/

ST1

C10

X15 .3

FR2

HSS4X2X18/

DOOR

7'-8

DOOR

DOOR

DOOR

DOOR

FR7

HSS4X2X18/

GR9

PIP

E1- 1 4/ S

CH40

GR7

PIPE1-14/ SCH40

FR2

HSS4X2X18/

HMD4

HSS4X2X18/

FR6

HSS4X2X18/

PIPE1-14/ SCH40

PIPE1-14/ SCH40

HMD1

HSS4X2X18/

HMD1

HSS4X2X18/

HMD1

HSS4X2X18/

HMD3

HSS4X2X18/

HMD1

HSS4X2X18/

DOOR

DOOR

5TH FLOOR

8'-0

212/

3' -6

2'-43'-0

9' -6

9' -6

'-6

2' -2

7' -0

3'-03'-10

3'-02'-412/

2' -2

7' -0

2 2

5'-102'-0

11'-10

7'

-0

HMD7

HSS4X2X18/

3'-0

3' -6

15'-8

DOOR

PIPE1-14/ SCH40

2' -2

PIPE1-14/ SCH40

7'-8

3RD FLOOR

5TH FLOOR

40'-0

1ST FLOOR

GROUND FL

15'-8

4TH FLOOR

FR7

HSS4X2X18/

'-6

DOOR

2' -2

2ND FLOOR

15'-8

DOOR

DOOR

FR6

HSS4X2X18/

3'-0

HMD3

HSS4X2X18/

9' -6

9' -6

9' -6

9' -6

9' -6

212/

3' -6

212/

11'-1010

7' -0

39'-8

7'-815'-8