ERECTION_DRAWING_E3.pdf

PDF 95 KB Posted

Attached to
CFD Training Facility Project
Solicitation number
IFB-2025-037
Issued by
Hamilton County, Indiana

About this file

This document is a Tekla Structures 2nd Floor Plan View drawing for the Carmel Fire Training project, issued for approval on 10/13/2025. The technical architectural drawing provides a detailed floor plan view with precise measurements, structural elements, and grid references. The plan includes multiple structural components such as steel columns (ST1 C10X15.3, CH2 C7X9.8, CH3 C4X5.4), pipe elements (GR9 PIPE1-1/4SCH40, GR12 PIPE1-1/4SCH40), and plate elements (EP1 PL 3/8"X7). The drawing indicates multiple grid lines, openings, and continuous inner and outer contours, with a note instructing verification of all details and dimensions in the field.

The technical drawing, dated 02/18/2022, appears to be part of the design documentation for a fire training facility, with a focus on precise structural measurements and layout. The plan view shows a complex grid system with multiple sections, stairs, and structural intersections, suggesting a multi-functional training space. While specific construction or procurement details are not provided, the drawing represents a critical stage in the architectural and engineering design process for the Carmel Fire Training project, demonstrating meticulous planning and structural considerations.

View the file

Other files

File Type Posted
CFD_Training_Facility_Project.pdf PDF
ERECTION_DRAWING_E19.pdf PDF
ERECTION_DRAWING_E4.pdf PDF
ERECTION_DRAWING_E8.pdf PDF
ERECTION_DRAWING_E1.pdf PDF
ERECTION_DRAWING_E10.pdf PDF
ERECTION_DRAWING_E11.pdf PDF
ERECTION_DRAWING_E15.pdf PDF
ERECTION_DRAWING_E17.pdf PDF
ERECTION_DRAWING_E20.pdf PDF
ERECTION_DRAWING_E5.pdf PDF
ERECTION_DRAWING_E7.pdf PDF
ERECTION_DRAWING_E12.pdf PDF
ERECTION_DRAWING_E14.pdf PDF
ERECTION_DRAWING_E16.pdf PDF
ERECTION_DRAWING_E18.pdf PDF
ERECTION_DRAWING_E2.pdf PDF
ERECTION_DRAWING_E6.pdf PDF
ERECTION_DRAWING_E9.pdf PDF
ERECTION_DRAWING_E13.pdf PDF
CFD_CTC_Close_Up.png PNG image
CFD_CTC_Training_Tower_Location.png PNG image
CFD_CTC_Whole_Parcel-1.png PNG image
6._Comprehensive_Set_of_Technical_Specifications_2021-04-28_(V2.7).docx DOCX document
MAINTENANCE_BOND.pdf PDF
NON_COLLUSION_AFFIDAVIT.pdf PDF
REQUEST_FOR_PROPOSAL_CHANGE.pdf PDF
RIGHT_OF_ENTRY.pdf PDF
CONTRACT_CHANGE_ORDER.pdf PDF
CONTRACT_CHANGE_REQUEST.pdf PDF
Exhibit_D_E-Verify-1.PDF PDF
FIELD_ORDER.pdf PDF
PERFORMANCE_BOND.pdf PDF
SAMPLE_OF_MOU_FOR_E-VERIFY.pdf PDF
MANUFACTURERS_LIST.pdf PDF
PAYMENT_BOND.pdf PDF
SAMPLE_AGREEMENT.pdf PDF
SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf PDF
SUBCONTRACTORS_LIST.pdf PDF
WORK_DIRECTIVE_CHANGE.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Te kl a st ru ct ur es

10/13/2025A ISSUED FOR APPROVAL

REV DESCRIPTION DATE

DESCRIPTION

PROJECT NAME

DRAWN BY

DATE DRAWN

JOB No. DRG No.

2nd FLOOR PLAN VIEW

CARMEL FIRE TRAINING

ABC

02/18/2022 - E3

2nd FLOOR PLAN VIEW

CONT. INNER TO INNER

CONT. OUTER TO OUTER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNER

CONT. INNER TO INNER

V.I.F.

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. OUTER TO OUTER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNER

CONT. OUTER TO OUTER

O

PE

N

IN

G

CONT. OUTER TO OUTER

C O

N T.

IN

N

ER

T

O

IN

N

ER

CONT. OUTER TO OUTER

V, I,F

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

CONT. INNER TO INNER

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

IN

N

ER

T

O

IN

N

ER

OPENING

C O

N T.

IN

N

ER

T

O

IN

N

ER

C O

N T.

O U

TE

R

T O

O U

TE

R

C O

N T.

O U

TE

R

T O

O U

TE

R

ALL DETAILS & DIMENSION VERIFY IN FILD

NOTE:-

7'-8

8'-0

812/

2'-8

'-5

4' -8

7' -8

8' -0

8' -0

2/

ST1

C10X15.3

7'-8

2/

1 4/

4'-638/2

19'-412/

4/

2' -8

312/

21'-634/

ST

C

X1 5.

7' -8

312/

8' -0

ST1

C10X15.3

8'-0

G R

PI

PE

1-

1 4/

SC

H

2' -8

7' -8

2/

'-0

39'-5

312/

4' -0

8'-0

GR12

PIPE1-14/ SCH40

8' -7

7 8/

558/

64'-0

EP1

PL38/ "X7

40'-0

8/

CH2

C7X9.8

7' -8

'-0

20'-0

6' -3

5 8/

8/

GR8

PIPE1-14/ SCH40

CH3

C4X5.4

CH3

C4X5.4

C H

C

4X 5.

GR14

PIPE1-14/ SCH40

ST1

C10X15.3

ST1

C10X15.3

GR14

PIPE1-14/ SCH40

EP1

PL38/ "X7

EP1

PL38/ "X7

EP1

PL38/ "X7

8' -0

'-0

5'-3 4'

-5 5 8/

3 8/

2' -8

2 2

7'-8

312/

'-5

7' -8

3' -3

1 4/

14'-134/5'-234/

2/

812/

812/ 812/

3'-514/

7' -8

8' -0

8' -0

File details come from the government source that posted it. Updated .