ERECTION_DRAWING_E13.pdf
PDF 80 KB Posted
- Attached to
- CFD Training Facility Project
- Solicitation number
- IFB-2025-037
- Issued by
- Hamilton County, Indiana
About this file
This document is a Tekla Structures architectural elevation drawing for the Carmel Fire Training facility, dated 10/13/2025. The technical drawing depicts a multi-story building with detailed floor plans and elevation views, showing measurements, floor heights, and structural components. The drawing includes precise measurements for each floor level, ranging from ground level (EL.+0") to the top floor at EL.+60'-0", with floor-to-floor heights of approximately 9'-6" to 10'-6". The elevation views show multiple structural elements including HSS (Hollow Structural Section) steel members, windows, doors, and splice locations across different floors.
The drawing provides comprehensive technical details for construction, with specific annotations for structural components like FR3 HSS4X2X1/8 members, pipe connections, and window placements. The design appears to be for a fire training facility, suggesting a specialized building meant for firefighter training purposes. The detailed technical specifications indicate a precise engineering approach, with careful attention to structural integrity, spatial relationships, and functional requirements of each floor level. The drawing is issued for approval and includes multiple views to provide a complete understanding of the building's structural and architectural configuration.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Te kl a st ru ct ur es
10/13/2025A ISSUED FOR APPROVAL
REV DESCRIPTION DATE
DESCRIPTION
PROJECT NAME
DRAWN BY
DATE DRAWN
JOB No. DRG No.
ELEVATION
CARMEL FIRE TRAINING
ABC
10/10/2025 - E13
9 - 9 E1
5 - 5 E1
EL.+19'-0"
EL.+9'-6"
EL.+0"
EL.+28'-6"
EL.+38'-0"
EL.+47'-6"
EL.+47'-6"
EL.+0"
EL.+9'-6"
EL.+19'-0"
EL.+28'-6"
EL.+38'-0"
EL.+60'-0"
CONT. OUTER TO OUTER
CONT. INNER TO INNER
V.
I.F
V.
I.F
V.
I.F
CONT. INNER TO INNER
CONT. OUTER TO OUTERCONT. OUTER TO OUTER
CONT. INNER TO INNER
40'-0
FR3
HSS4X2X18/
3RD FLOOR
312/ 6'-0
5'-0
FR3
HSS4X2X18/
16'-812/
17'-212/
9' -6
39'-5
3' -2
2' -4
2ND FLOOR
C
FR1
HSS4X2X18/
GROUND FL
2'-91516/
2' -417'-212/
WINDOW
PIPE1-14/ SCH40
GR6
PIPE1-14/ SCH40
FR3
HSS4X2X18/
5'-0
PIPE1-14/ SCH40
312/
L OFSPLICE L OFSPLICE
C
L OFSPLICE
C
FR2
HSS4X2X18/
GR5
PIPE1-14/ SCH40
WINDOW
WINDOW
312/
WINDOW
WINDOW
FR3
HSS4X2X18/
DOORHMD1
HSS4X2X18/
5TH FLOOR
4TH FLOOR
4' -0
1ST FLOOR
1'-0
4' -0
2'-91516/ 1'-0
6'-1112/
9' -6
9' -6
9' -6
9' -6
5'-017'-212/312/
5'-0
312/ 17'-212/
2' -4
4' -0
3' -2
3' -2
2' -4
4' -0
3' -2
2' -2
7' -0
1' -1
4'
-0 3'
-4
212/39'-7212/
'-6
2' -1
GROUND FL
L OFSPLICE
7'-212/
FR10
HSS4X2X18/
4TH FLOOR
2 4
WINDOW
4' -0
7'-8
7'-212/
2' -1
WINDOW
5'-0
FR3
HSS4X2X18/
WINDOW
C
6'-0
FR3
HSS4X2X18/
2' -1
WINDOW
'-6
2' -4
312/
WINDOW
7'-212/
2' -4
4' -0
5'-0
2'-6
3' -2
WINDOW
2' -1
FR3
HSS4X2X18/
GR18
PIPE1-14/ SCH40
GR19
PIPE1-14/ SCH40
PIPE1-14/ SCH40
4' -0
L OFSPLICE
C
WINDOW
39'-7
WINDOW
9' -6
WINDOW
2' -1
WINDOW
DOOR
5'-0
FR3
HSS4X2X18/
40'-0
'-0
FR3
HSS4X2X18/
FR3
HSS4X2X18/
FR3
HSS4X2X18/
FR3
HSS4X2X18/
FR4
HSS4X2X18/
FR4
HSS4X2X18/
DET. 5
E17
HMD11
HSS4X2X18/
1ST FLOOR
2ND FLOOR
7'-212/
3RD FLOOR
5TH FLOOR
212/212/
1'-0 2'-91516/2'-91516/
4'-64'-62'-69'-812/
9' -6
9' -6
9' -6
9' -6
8'-0
2' -2
7' -0
2' -4
4' -0
4' -0
2' -4
4' -0
7'-212/5'-0
2' -4
4' -0
2' -1
2' -4
2' -1
7'-212/5'-0
2' -1
2' -1
2'
-4
5'-0 7'-212/5'-0
2' -4
4' -0
7'-212/5'-0
4' -0
2' -4
39'-5
4' -0
2' -4
2 312/
File details come from the government source that posted it. Updated .