ERECTION_DRAWING_E11.pdf

PDF 91 KB Posted

Attached to
CFD Training Facility Project
Solicitation number
IFB-2025-037
Issued by
Hamilton County, Indiana

About this file

This is an architectural elevation drawing for the Carmel Fire Training facility, created using Tekla Structures software and dated 10/10/2025. The drawing provides a detailed vertical cross-section of a multi-story building, showing floor elevations from ground level to 60 feet, with precise measurements and structural elements. The elevation includes various floor levels, doors (including overhead roll-up doors), and structural components such as HSS (Hollow Structural Section) tubes, pipes, and steel beams. The drawing indicates multiple floors with different heights and configurations, suggesting a complex multi-purpose training facility for fire personnel. Specific structural elements are labeled with codes like HMD9, FR6, and CH3, and the drawing includes detailed annotations for pipe sizes, door placements, and structural connections. The document is marked "ISSUED FOR APPROVAL" on 10/13/2025, indicating it is a preliminary design document for review and potential construction of a fire training facility.

View the file

Other files

File Type Posted
CFD_Training_Facility_Project.pdf PDF
ERECTION_DRAWING_E19.pdf PDF
ERECTION_DRAWING_E4.pdf PDF
ERECTION_DRAWING_E8.pdf PDF
ERECTION_DRAWING_E1.pdf PDF
ERECTION_DRAWING_E10.pdf PDF
ERECTION_DRAWING_E15.pdf PDF
ERECTION_DRAWING_E17.pdf PDF
ERECTION_DRAWING_E20.pdf PDF
ERECTION_DRAWING_E5.pdf PDF
ERECTION_DRAWING_E7.pdf PDF
ERECTION_DRAWING_E13.pdf PDF
ERECTION_DRAWING_E12.pdf PDF
ERECTION_DRAWING_E14.pdf PDF
ERECTION_DRAWING_E16.pdf PDF
ERECTION_DRAWING_E18.pdf PDF
ERECTION_DRAWING_E2.pdf PDF
ERECTION_DRAWING_E3.pdf PDF
ERECTION_DRAWING_E6.pdf PDF
ERECTION_DRAWING_E9.pdf PDF
CFD_CTC_Close_Up.png PNG image
CFD_CTC_Training_Tower_Location.png PNG image
CFD_CTC_Whole_Parcel-1.png PNG image
6._Comprehensive_Set_of_Technical_Specifications_2021-04-28_(V2.7).docx DOCX document
MAINTENANCE_BOND.pdf PDF
NON_COLLUSION_AFFIDAVIT.pdf PDF
REQUEST_FOR_PROPOSAL_CHANGE.pdf PDF
RIGHT_OF_ENTRY.pdf PDF
CONTRACT_CHANGE_ORDER.pdf PDF
CONTRACT_CHANGE_REQUEST.pdf PDF
MANUFACTURERS_LIST.pdf PDF
PAYMENT_BOND.pdf PDF
SAMPLE_AGREEMENT.pdf PDF
SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf PDF
SUBCONTRACTORS_LIST.pdf PDF
WORK_DIRECTIVE_CHANGE.pdf PDF
Exhibit_D_E-Verify-1.PDF PDF
FIELD_ORDER.pdf PDF
PERFORMANCE_BOND.pdf PDF
SAMPLE_OF_MOU_FOR_E-VERIFY.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESCRIPTION

PROJECT NAME

DRAWN BY

DATE DRAWN

JOB No. DRG No.

ELEVATION

CARMEL FIRE TRAINING

ABC

10/10/2025 - E11Te kl a st ru ct ur es

10/13/2025A ISSUED FOR APPROVAL

REV DESCRIPTION DATE

10 - 10 E1

6 - 6 E1

EL.+9'-6"

EL.+0"

EL.+38'-0"

EL.+47'-6"

EL.+0"

EL.+9'-6"

EL.+19'-0"

EL.+28'-6"

EL.+60'-0"

V.I.F.V.I.F.

V.I.F.

V.

I.F

CONT. INNER TO INNER CONT. INNER TO INNER

CONT. OUTER TO OUTER

CONT. OUTER TO OUTER CONT. OUTER TO OUTERCONT. OUTER TO OUTERCONT. OUTER TO OUTER

CONT. INNER TO INNER

CONT. OUTER TO OUTER

CONT. INNER TO INNER CONT. INNER TO INNER CONT. INNER TO INNER

1' -2

212/

GR4

PIPE1-14/ SCH40

312/17'-212/

OPENING

CL OF SPLICE L OF SPLICEC

PL38/ "X4

GR2

PIPE1-14/ SCH40

7' -0

GR1

PIPE1-14/ SCH40 GR3

PIPE1-14/ SCH40

DET. 7

E19

DET. 8

E19

DOOR

OVERHEAD

ROLL UP

1ST FLOOR

GROUND FL

3' -6

2'-2316/

1'-0 1'-0 21116/1'-6234/

1 2/ 9@

1' -0

=9 '-0

2/

36'-7916/ 1'-11716/

1'-0212/

5'-0

7' -0

HMD10

HSS4X2X18/

2'-4

GROUND FL

HMD9

HSS4X2X18/

3RD FLOOR

DOOR

7116/

4TH FLOOR

2'-4

7'-8

CH3

C4X5.4

DOOR

CH3

C4X5.4

7'-8

FR6

HSS4X2X18/

3'-0

8'-0

HMD9

HSS4X2X18/

7' -0

9' -6

GR15

PIPE1-14/ SCH40

7'-8

DOOR

FR6

HSS4X2X18/

GR14

3' -6

2'-4

FR10

HSS4X2X18/

DOOR

2'-4

8'-0

DOOR

HMD9

HSS4X2X18/

2' -2

5TH FLOOR

HMD11

HSS4X2X18/

1ST FLOOR

8'-0

2'-4

GR13

GR12

'-0

7116/

2'-4

2'-1058/

6'-0

DOOR

3'-0

FR6

HSS4X2X18/

DOOR

GR17

2ND FLOOR

434/

HMD11

HSS4X2X18/

3'-71116/

3' -6

DOOR

DOOR

DOOR

FR10

HSS4X2X18/

DOORDOOR

CH3

C4X5.4

GR12

3'-51116/ FR6

HSS4X2X18/

GR14

CH3

C4X5.4

3' -6

7' -0

3' -6

858/2'-1058/434/

3'-912/ 41316/

2'-1058/

'-6

9' -6

9' -6

9' -6

9' -6

2' -2

7' -0

2' -2

858/

434/3'-314/

3'-314/

7' -0

43'-0

8'-0

42'-4

8'-0

3'-0

2'-4

7'-8

8'-0

1'-06'-010

47'-8447'-87'-8

8'-0

7'-8

22 2 2 2 2

7'-8 7'-8