Attachment 7 - Architectural Drawings 1 of 2.pdf
PDF 17 MB Posted
- Attached to
- Y1DA--Expand and Renovate Emergency Department B50 Minor Construction - Tucson VAMC (VA-24-00001448)
- Solicitation number
- 36c77623r0191
About this file
This document provides details on a federal contract opportunity for architectural services. The solicitation number is 36c77623r0191 to expand and renovate the emergency department at the Tucson Veterans Affairs Medical Center located in Tucson, Arizona. The opportunity type is a solicitation issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The scope of work involves expanding and renovating the emergency department facility. Attachment 7 to the solicitation includes architectural drawings part 1 of 2 with unspecified content. No further salient details on requirements, pricing, or timelines are provided in this document.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EARTH
GRAVEL
CONCRETE
CONCRETE MASONRY UNITBRICK MASONRY
STEEL/STAINLESS STEEL
ALUMINUM
SHIM OR NAILER
PLYWOOD
HARDWOOD
RIGID INSULATION
BATT INSULATION
MORTAR/SAND/STUCCO/
GYPSUM BOARD SURFACE
ACOUSTIC CEILING
CERAMIC TILE
SECTION NUMBER
SHEET WHERE DRAWN
DETAIL NUMBER
SHEET WHERE DRAWN
NAME OF LEVEL
HEIGHT ABOVE PROJECT DATUM
XXX
X
XXXX
BUILDING & WALL SECTION
EXTERIOR ELEVATION
DETAIL BUBBLE
SECTION DETAIL
INTERIOR ELEVATION
MATCH LINE VIEW
PARTITION TYPE
WINDOW NUMBER
DOOR NUMBER
ROOM TAG
ELEVATION TAG
EQUIPMENT NUMBER
Room name
XXX
ELEVATION
0'-0"
REVISION NUMBERX
XXXX
X
XXXX
X
XXXX
X
X
X
X
FLOOR PLAN NUMBER AND SHEET
WHERE DRAWN
XXXX
X
XX
XX
XXX
ROOM NAME
ROOM NUMBER
ELEVATION NUMBER
SHEET WHERE DRAWN
ELEVATION NUMBER AND DIRECTION OF VIEW
SHEET WHERE DRAWN
DETAIL NUMBER
SHEET WHERE DRAWN
/ XXXXX
DEMOLITION KEYNOTE 1
KEYNOTE 1
DRAWING TITLE AND SCALE
NORTH ARROWN
View Name 1/8" = 1'-0"
0 4' 8' 16'
MA
X
3'
- 4
8"
MA
X
2'
- 1
0"
MIN
3' - 0"
MAX
6"
ST
AN
DA
RD
1'
- 3
MAX
1' - 6"
3' - 4"
MI
N
1'
- 6
MIN
3' - 6"
MAX
1' - 0"
2'
- 9
AC
CE
SS
IBL
E
" M
AX
3'
- 8
1' - 6"
3'
- 8
6'
- 0
SHOWER
CONTROL
3'-0" MIN. SHOWER
SLIDE BAR WITH 5'-0"
SHOWER HOSE
4'
- 0
ACCESSIBLE TOILET ROOM
SIDE ELEVATION
ACCESSIBLE TOILET ROOM
FRONT ELEVATION
ACCESSIBLE TOILET ROOM
SIDE ELEVATION
BULLETIN BOARD
OR WHITEBOARD
MOP & BROOM
HOLDER
6'
- 0
"7'
- 0
CLOCK OR
CLOCK OUTLET
GLOVES
DISPENSER
SHARPS
DISPOSAL
FLAT SCREEN
TV / MONITOR
4'
- 0
ACCESSIBLE SHOWER
2"
2'
- 2
SANITARY
NAPKIN
DISPENSER
DIAPER CHANGING STATION SOAP/SANITIZER
DISPENSER
PAPER TOWEL
DISPENSER
MIN
1' - 3" 5" MAX
3'
- 0
" M
AX
2'
- 9
" M
IN
2'
- 3
" M
IN
MIN
8"
MIN
11"
MI
N9"
DRINKING FOUNTAIN
OR WATER COOLER
(SIDE ELEVATION)
4'
- 0
COAT HOOK
WALL MOUNTED
3'
- 4
RECESSED
SOAP DISH
LIGHT
SWITCH &
DIMMER
DUPLEX
OUTLET
ELECTRICAL, DATA,
TELEPHONE OUTLETS
AC
CE
SS
IBL
E
4'- 0"
MA
X
HI
GH
R
EA
CH
1'
- 6
CARD READER,
LOCAL ALARM, OR
ARMING STATION
AT DOOR OR CASED OPENING
8" TYP
8" COUNTER
6"
5'
- 6
EQ EQ
6'
- 0
2'
- 1
0"
1'
- 6
9"6"
1' - 5"
2'
- 3
5'
- 0
MED GAS
OUTLETS
NURSE
CALL
6'
- 0
FULL LENGTH MIRROR
4'
- 0
COAT HOOK
DOOR MOUNTED
FIRE
EXTINGUISHER
CABINET
(FEC)
BLOCKING
BLOCKING
MEDICAL GAS OUTLETS
EQUIPMENT, PANEL BOARD,
CABINET, OR SIMILAR
FEATURE
HANDRAIL OR WALL GUARD
TYPE NO 1 (SHOWN), TYPE NO
2, CORNER OR EDGE GUARD
WHERE HANDRAILS OR WALL
GUARDS TERMINATE
WALL GUARD
DOOR FRAME OR CASED
OPENING FRAME
OUTLET OR SIMILAR
OUTLET OR SIMILAR WHEN
ADJ TO FRAME
WHERE HANDRAIL OR WALL
GUARD TERMINATE
TYPE NO 2 (SHOWN), TYPE NO
1, CORNER OR EDGE GUARD
2'-
" U
NO
1'- 4"
UN
O
6" 4'-
0"
TY
PE
2" TYP
2" TYP 2" TYP
4" TYP 4" TYP
2" TYP
6" 6'-
8"
TY
PE
N O
2" TYP
8" 4" TYP
HEIGHT OF VINYL WALL
PROTECTION (WHERE
APPLICABLE)
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
05/01/2023ARCHITECTURAL -
ABBREVIATIONS, SYMBOLS &
TYPICAL MOUNTING HEIGHTS
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-A001
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
R
R RADIUS
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
REINF REINFORCED
REQD REQUIRED
RM ROOM
RO ROUGH OPENING
S
S SOUTH
SAN SANITARY
SCHED SCHEDULE
SF SQUARE FOOT (FEET)
SHT SHEET
SIM SIMILAR
SOW SCOPE OF WORK
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
SUSP SUSPEND
SV SHEET VINYL
T
T&G TOUNGE AND GROOVE
TEMP TEMPERED
TERR TERRAZZO
THK THICK
TO TOP OF
TSTAT THERMOSTAT
TYP TYPICAL
U
UNO UNLESS NOTED OTHERWISE
V
VA VETERANS ADMINISTRATION
VAR VARIES
VC VA SUPPLIED, CONTRACTOR INSTALLED
VCT VINYL COMPOSITION TILE
VENT VENTILATION
VIF VERIFY IN FIELD
VOL VOLUME
VV VA SUPPLIED & INSTALLED
VWC VINYL WALL COVERING
W
W WEST
W/ WITH
W/O WITHOUT
WC WALL COVERING
WD WOOD
WDW WINDOW
WWM WELDED WIRE FABRIC
L
LAM LAMINATE
LAV LAVATORY
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LL LEAD LINED
LT LIGHT
M
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MLWK MILLWORK
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTG MOUNTING
MTL METAL
N
N NORTH
N/A NOT APPLICABLE
NAT NATURAL
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OFIC OWNER FURNISHED INSTALLED BY
CONTRACTOR
OH OPPOSITE HAND
OPNG OPENING
OPT OPTIONAL
P
PAT PATTERN
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PR PAIR
PRE PREFINISHED
PREP PREPARATION
PROVIDE FURNISH AND INSTALL
PT PAINT
PTME PAINT TO MATCH EXISTING
PTN PARTITION
PWR POWER
Q
QT QUARRY TILE
QTR QUARTER
QTY QUANTITY
E
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FA FIRE ALARM
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE AND EQUIPMENT
FHC FIRE HOSE CABINET
FIG FIGURE
FIN FINISH
FIXT FIXTURE
FL FLOOR
FO FACE OF
FP FIRE PROTECTION OR FIREPROOF
FT FOOT
FTG FOOTING
G
GA GAUGE
GC GENERAL CONTRACTOR
GL GLASS
GYP BD GYPSUM BOARD
H
HAZ MAT HAZARDOUS MATERIALS
HDW HARDWARE
HM HOLLOW METAL
HT HEIGHT
I
INCL INCLUDED
INSUL INSULATION
INT INTERIOR
J
J-BOX JUNCTION BOX
JAN JANITOR
JC JANITOR'S CLOSET
JSN JOINT SCHEDULE NUMBER
JST JOIST
JT JOINT
A
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
AR AS REQUIRED
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVG AVERAGE
B
BAT BATTEN
BD BOARD
BLDG BUILDING
BLK BLOCKING
BM BEAM
BO BY OWNER
BOD BASIS OF DESIGN
C
CC CONTRACTOR SUPPLIED & INSTALLED
CEM CEMENT
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACT OFFICER
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACT OFFICER REPRESENTATIVE
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CTRL CONTROL
D
DAT DATUM
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
ARCHITECTURAL ABBREVIATIONSGRAPHIC SYMBOLS STANDARD MOUNTING HEIGHTS
MATERIAL INDICATIONS
THIS SHEET TO BE USED FOR STANDARD MOUNTING HEIGHTS ONLY AND
NOT ACCURATE GRAPHICAL REPRESENTATIONS OF SCHEDULED FIXTURES
AND EQUIPMENT. SEE DISCIPLINE DRAWINGS FOR MORE INFORMATION.
WALL PROTECTION MOUNTING HEIGHTS
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
50-A701
BLDG 50
FIRST FLOOR ELEVATION: 59' - 8 3/8"
' - 0
0"
0"
5'
- 0
5' - 0"
' - 0
' - 1
0 1 /2"
4 1 /4"
100017
50-A701
.0
50-A701 o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
05/01/2023ARCHITECTURAL - SITE PLAN EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-AS101
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
N 1/8" = 1'-0"
ARCHITECTURAL SITE PLAN
KEYNOTES
1 EXISTING ENCLOSURE TO REMAIN.
2 EXISTING BACKFLOW PREVENTER TO REMAIN.
3 POWDER COATED ALUMNINUM GATE AND SUPPORTING STRUCTURE.
REFER TO 17/50-A701 AND CIVIL DRAWINGS MORE INFORMATION. REFER
TO DOOR SCHEDULE FOR HARDWARE REQUIREMENTS.
4 FUTURE ELEVATOR. NOT INCLUDED IN SCOPE OF WORK.
5 REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL STEEL. REFER
TO 16/50-A701 FOR COLUMN ENCLOSURE.
6 NEW SITE WORK. REFER TO CIVIL SITE PLAN FOR MORE INFORMATION.
7 ANTI-RAM BOLLARDS PROVIDED AND INSTALLED BY GC. REFER TO
SPECIFICATION SECTION 34 71 13.
8 OUTLINE OF NEW CANOPY ABOVE.
9 LANDSCAPING BY VA.
GENERAL SITE NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CIVIL, PLUMBING AND ELECTRICAL DRAWINGS
FOR FULL SCOPE OF SITE WORK.
2. CONTRACTOR TO MAINTAIN PEDESTRIAN AND VEHICULAR ACCESS TO EMERGENCY
DEPARTMENT. PROVIDE SIGNS REROUTING PEDESTRIAN AND VEHICULAR TRAFFIC AS
NEEDED.
3. PROTECT EXISTING BUILDING AND SITE MATERIALS THAT ARE INDICATED TO REMAIN. ALL
MATERIALS DAMAGED DURING DEMOLITION/CONSTRUCTION SHALL BE REPAIRED BY THE
CONTRACTOR. MATCH ADJACENT FINISHES.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR TRACING AND IDENTIFYING ALL EXISTING SITE
UTILITIES WITHIN AND PASSING THROUGH THE AREA OF WORK. COORDINATE ALL UTILITY
SHUT DOWNS WITH THE VA/COR.
5. SITE WORK WILL BE DONE IN PHASES.
0 4' 8' 16'
Revisions: Date:
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
Revisions: Date:
FF
EE
DD
CC
B
2 2
45 5 1
1 1 1
1 1
11 9 11 9
12 12 12 12
50-AD201
129 131 132
134 135
118 116 115
113A
112114 113B
147149
143 144
105A
138 139
1V2 o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
05/01/2023ARCHITECTURAL - DEMOLITION
REFLECTED CEILING PLAN, FIRST
FLOOR
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-ACD101
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
N 1/8" = 1'-0"
DEMOLITION REFLECTED CEILING PLAN
1 REMOVE EXISTING CEILING, GRID, AND ACOUSTICAL TILE, INCLUDING ALL
RELATED MOLDINGS, TRIM, WIRESUPPORTS, AND/OR BRACING
THROUGHOUT THE AREA. REMOVE EXISTING LIGHT FIXTURES, GRILLES,
EXIT LIGHTING, AND OTHER EQUIPMENT. ANY MISCELLANEOUS EQUIPMENT
FOUND ABOVE THE CEILING TO BE RELOCATED OR TURNED OVER TO THE
VA/COR.
2 REMOVE EXISTING GYPSUM BOARD CEILING COMPLETE. REMOVE EXISTING
LIGHT FIXTURES, GRILLES, EXIT LIGHTING, HATCHES, AND OTHER
EQUIPMENT. ANY MISCELLANEOUS EQUIPMENT FOUND ABOVE THE
CEILING TO BE RELOCATED OR TURNED OVER TO THE VA/COR.
3 REMOVE EXISTING GYPSUM BOARD SOFFIT AND BULKHEAD COMPLETE.
REMOVE EXISTING LIGHT FIXTURES, GRILLES, AND OTHER EQUIPMENT.
ANY MISCELLANEOUS EQUIPMENT FOUND ABOVE THE CEILING TO BE
RELOCATED OR TURNED OVER TO THE VA/COR.
4 REMOVE PORTION OF EXISTING CEILING, GRID, AND ACOUSTICAL TILE,
INCLUDING ALL RELATED MOLDINGS, TRIM, WIRESUPPORTS, AND/OR
BRACING THROUGHOUT THE AREA. COORDINATE EXTENT OF REMOVAL
WITH NEW WORK. ANY MISCELLANEOUS EQUIPMENT FOUND ABOVE THE
CEILING TO BE RELOCATED OR TURNED OVER TO THE VA/COR. PROTECT
EXISTING ADJACENT CEILING AND EQUIPMENT TO REMAIN.
5 REMOVE EXISTING LIGHT FIXTURES. REFER TO ELECTRICAL DRAWING
50-ELD101.
6 REMOVE EXISTING GRILLE/DIFFUSER. REFER TO MECHANICAL DRAWING
50-MHD101.
7 REMOVE EXISTING EXTERIOR CANOPY COMPLETE.
8 NO CEILING WORK IN THIS AREA. EXISTING LIGHTING TO BE REPLACED.
9 REMOVE AND SALVAGE EXISTING SURGICAL LIGHT.
10 REMOVE EXISTING CURTAIN TRACK.
11 REMOVE AND SALVAGE EXISTING CEILING LIFT.
12 REMOVE EXISTING TV, TV MOUNT, AND ASSOCIATED COMPONENTS.
13 REMOVE CEILING AS REQUIRED FOR NEW CONSTRUCTION. TEMPORARILY
SUPPORT THE EXISTING CEILING TO REMAIN WHERE CEILING DEMOLITION
OCCURS.
GENERAL DEMOLITION PLAN NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING CIVIL, FIRE PROTECTION,
PLUMBING, MEDICAL GAS, MECHANICAL, ELECTRICAL AND TECHNOLOGY DRAWINGS FOR
FULL SCOPE OF DEMOLITION WORK. COORDINATE EXTENTS OF DEMOLITION WITH NEW PLAN.
2. REFER TO SHEET GI002 FOR GENERAL DEMOLITION NOTES.
3. SALVAGE ALL CEILING MOUNTED ITEMS. REVIEW WITH OWNER ITEMS TO BE KEPT AND
WHERE TO STORE KEPT ITEMS.
4. REMOVE ALL POWER WIRING, CONDUITS, JUNCTION BOXES AND SUPPORT SYSTEMS
ASSOCIATED WITH REMOVED CEILING MOUNTED ITEMS. REMOVE WIRING BACK TO
RESPECTIVE POWER PANELS. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION.
5. DEMOLITION TO BE DONE IN PHASES. REFER TO PHASING DRAWINGS.
DEMOLITION RCP LEGEND
REMOVE EXISTING CEILING TILE AND GRID INCLUDING HANGERS.
REMOVE EXISTING 2X4 LIGHT FIXTURE.
REFER TO ELECTRICAL DRAWINGS.
REMOVE EXISTING 2X2 LIGHT FIXTURE.
REFER TO EXISTING ELECTRICAL DRAWINGS.
AREA NOT IN CONTRACT
DEMOLITION PLAN KEYNOTES
0 4' 8' 16'
Revisions: Date:
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
7 8
FF
EE
DD
CC
BB
2 2
2 2 2 2
5 5
8 8
8 8 8
8 1
8 8
8' - 9" 31' - 2 1/4"
7 9
17 17
134 135 136
118 116 115
113A
112114
113B145
105A
138 139
1V2
1C1
SH2-50
o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
05/01/2023ARCHITECTURAL - DEMOLITION
PLAN, FIRST FLOOR
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-AD101
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
N 1/8" = 1'-0"
DEMOLITION PLAN
GENERAL DEMOLITION PLAN NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING CIVIL, FIRE PROTECTION,
PLUMBING, MEDICAL GAS, MECHANICAL, ELECTRICAL AND TECHNOLOGY DRAWINGS FOR
FULL SCOPE OF DEMOLITION WORK. COORDINATE EXTENTS OF DEMOLITION WITH NEW PLAN.
2. REFER TO SHEET GI001 FOR GENERAL DEMOLITION NOTES.
3. ALL CONSTRUCTION TO REMAIN THAT IS AFFECTED BY DEMOLITION SHALL BE PATCHED,
PLASTERED AND BE PROPERLY MEMBERED AND ALIGNED SO AS TO LEAVE NO EVIDENCE OF
PATCHING OR REPAIR.
4. DURING REMOVAL OF EXISTING FINISHES FROM ITEMS INDICATED TO REMAIN (FLOORS,
WALLS, ETC.), IF THE SUBSTRATE BECOMES DAMAGED BEYOND REPAIR, REPLACE DAMAGED
SECTION TO THE POINT WHERE NEW FINISHES CAN BE APPLIED WITHOUT DETECTION OF
DAMAGED AREAS.
5. EXISTING FURNITURE, EQUIPMENT, SUPPLIES, ETC. TO BE REMOVED BY OWNER PRIOR TO
START OF CONSTRUCTION. PRIOR TO COMMENCING WORK, THE VA/COR AND GC WILL WALK
SITE AND VA/COR WILL IDENTIFY ANY EXISTING ITEMS TO BE SALVAGED AND RETURNED TO
THE VA. ANY ITEMS NOT BEING SALVAGED SHALL BE REMOVED BY THE GC.
6. DEMOLITION WILL BE DONE IN PHASES. REFER TO PHASING DRAWINGS.
DEMOLITION PLAN LEGEND
EXISTING PARTITION WALL TO REMAIN.
ALL EXISTING WALLS TO REMAIN WITHIN PROJECT SCOPE ARE TO BE INSULATED.
REMOVE AND REINSTALL GYPSUM BOARD ON ONE SIDE OF WALL AS NECESSARY
TO INSTALL NEW INSTALLATION.
REMOVE PARTITION WALLS INDICATED BY DASHED LINES. REMOVE ELECTRICAL,
SWITCHES, PHONE AND DATA OUTLETS AND COVER PLATES AS REQUIRED TO
FACILITATE WALL REMOVAL.
REMOVE DOOR AND FRAME INDICATED BY DASHED LINES.
SALVAGE DOOR HARDWARE (LEVER LOCK SETS ONLY) FOR POSSIBLE REUSE.
STORE AS INDICATED BY OWNER.
NOT INCLUDED IN AREA OF WORK
DEMOLITION PLAN KEYNOTES
1 REMOVE EXISTING COUNTER AND ALL RELATED CASEWORK AND
SUPPORTS.
2 REMOVE EXISTING COUNTER, CASEWORK, FIXTURES, AND
ASSOCIATED PLUMBING.
3 REMOVE EXISTING DOOR, FRAME AND ALL ASSOCIATED HARDWARE.
4 REMOVE PORTION OF EXISTING FLOORING, RELATED ADHESIVE, AND
WALL BASE AS REQUIRED FOR NEW WORK.
5 REMOVE EXISTING PLUMBING FIXTURES AND ASSOCIATED PLUMBING.
CAP EXISTING PIPING AS REQUIRED. COORDINATE WITH PLUMBING
DRAWINGS.
6 REMOVE EXISTING WINDOW, FRAME AND ALL ASSOCIATED
HARDWARE.
7 REMOVE AND SALVAGE PLUMBING FIXTURES FOR REUSE.
COORDINATE WITH PLUMBING DRAWINGS.
8 REMOVE EXISTING FLOORING, RELATED ADHESIVE, AND WALL BASE.
9 REMOVE EXISTING CERAMIC TILE AT FLOOR AND WALLS, RELATED
GROUT, AND MUD BED AT FLOOR.
10 REMOVE PORTION OF EXISTING WALL TO ACCOMODATE NEW
CONSTRUCTION. COORDINATE WITH NEW WORK.
11 REMOVE AND SALVAGE EXISTING PNEUMATIC TUBE STATION AND
ASSOCIATED TRIM AND COMPONENTS. REMOVE PORTION OF
PNEUMATIC TUBE PIPING AS REQUIRED TO ACCOMMODATE NEW
WORK. COORDINATE EXTENT OF REMOVAL WITH NEW WORK.
12 REMOVE EXTERIOR CANOPY COMPLETE.
13 REMOVE EXISTING FIRE EXTINGUISHER, CABINET, TRIM, AND OTHER
ASSOCIATED COMPONENTS.
14 REMOVE PORTION OF CONCRETE SLAB AND FOUNDATION.
COORDINATE EXTENTS WITH NEW WORK.
15 REMOVE EXISTING STOREFRONT ASSEMBLY.
16 REMOVE EXISTING DOUBLE EGRESS DOORS ONLY. EXISTING FRAME
TO REMAIN. SALVAGE HARDWARE TO BE REUSED.
17 REMOVE WALL PROTECTION AS REQUIRED TO ALLOW FOR NEW WALL
AND DOORS.
0 4' 8' 16'
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
Floor 1 59'-8 3/8"
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8"
Floor 2 73'-8 3/8"
FEDCB
Floor 3 87'-8 3/8"
Floor 3 87'-8 3/8"
3 24
5 2
50-AD201
Floor 1 59'-8 3/8"
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8"
Floor 2 73'-8 3/8"
34567
Floor 3 87'-8 3/8"
Parapet 107'-8 3/8"
11 1
22 4 25
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8" o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
05/01/2023ARCHITECTURAL - EXTERIOR
DEMOLITION ELEVATIONS
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-AD201
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
1/8" = 1'-0"
EXTERIOR DEMOLITION ELEVATION - SOUTH
1/8" = 1'-0"
EXTERIOR DEMOLITION ELEVATION - EAST
DEMOLITION ELEVATION KEYNOTES
1 REMOVE EXISTING CANOPY COMPLETE.
2 REMOVE EXISTING WINDOW.
3 REMOVE EXISTING ENTRY SYSTEM.
4 REMOVE EXISTING DOOR.
5 REMOVE PORTION OF EXISTING WALL TO ALLOW FOR NEW OPENING.
COORDINATE WITH NEW WORK.
6 SAWCUT EXISTING CANOPY FROM EXISTING BEAM. MAKE FACE OF
EXISTING CANOPY SMOOTH.
7 EXISTING CONSTRUCTION TO BE REMOVED.
8 FLOOR DRAIN. SLOPE FLOOR TOWARDS DRAIN AT 1/8" PER FOOT.
REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.
9 EXISTING WINDOW TO REMAIN.
0 4' 8' 16'
0 4' 8' 16' 3/4" = 1'-0"
PARTIAL DEMOLITION BUILDING SECTION
0 2' 3'1'
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
UP
5 6 7
FF
4.6 5.5 6.3
II
HH
JJ
GG
50-A403
50-A401
50-A41014
50-A405
3 5
50-A201
50-A301
8.5 98.3
50-A301
50-A303
50-A302
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
(FAST TRACK)
HAC
SECURITY STATION
RECEPTION
WAITING
AOD SUPPORT
TRIAGE
TRIAGE
TOILET (STAFF)
STORAGE- AOD
PIT
CONSULT
SOILED UTILITY
EXAM/ TREATMENT
(LOW ACUITY)
1026D
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
(ISOLATION)
ANTEROOM
STORAGE- EMS
TOILET (ISOLATION
PATIENT)
1032A
MEDS
VESTIBULE
1V1
EXAM/ TREATMENT
(LOW ACUITY)
1026A
EXAM/ TREATMENT
(LOW ACUITY)
1026B
EXAM/ TREATMENT
(LOW ACUITY)
1026C
EXAM/ TREATMENT
(LOW ACUITY)
1026E
EXAM/ TREATMENT
(LOW ACUITY)
1026F
EXAM/ TREATMENT
(LOW ACUITY)
1026G
EXAM/ TREATMENT
(FAST TRACK)
CORRIDOR
C2
26' - 2" 21' - 0" 20' - 0" 16' - 2" 7' - 8" 11' - 4"
4"
6 1
/2"
7 1
/4"
/1 50-A101.4
ALCOVE- DRINKING
FOUNTAIN
1001C
CORRIDOR
C1
STAIR
SH2-50
50-A407 3
SF10
SF11
1 1 1 1 1 1
1A
3A
1A 2
3A
3A
3A 3A
3A
3A
1A
1 1 1 1
10' - 4 3/4" 10' - 4 3/4" 10' - 4 3/4" 10' - 4 3/4"
ALIGN
13' - 3"
10' - 5" 10' - 5" 10' - 5" 10' - 5" 10' - 5"
A
LI
G N
7'
- 5
7'
- 5
8'
- 1
0 1 /2"
7'
- 4
1/ 4"
9'
- 0
7'
- 1 1 3
/4"
4'
- 0
7' - 0"
14' - 0 1/4"
6"
7'-0" HIGH
4' - 0" 3' - 10"
6' - 0"
10' - 4 1/4" 8' - 0" 14' - 0"
5'
- 1
1/ 4"
0" 8'
- 0
13' - 0 1/2"
8'
- 0
8'
- 1
1"
8'
- 8
3/ 4"
5'
- 2
0"
0" 8'
- 9 1/
4"
8' - 3 1/2"
8' - 0 3/4" 10' - 3"
0 3 /4"
0"
9' - 11 1/2"
NURSE STATION-
EAST
TOILET (PUBLIC)
1001A
TOILET (PUBLIC)
1001B
CORRIDOR
C12
CORRIDOR
C13
CORRIDOR
C14
CORRIDOR
C3
CORRIDOR
C3
1 3/4"
5'
- 7
3/ 4"
5'
- 3
1/ 4"
7'
- 6
5'
- 1
1 1 /4"
1 1
1A
MH3 MH3 MH3 MH3
MH3
MH4
MH4
MH4
MH4
MH4
MH4
MH4
MH1
MH1 MH1
MH1
MH1
SF1SF1SF1
SF1
SF1
50-A304
50-A4071
50-A407
50-A408 8
50-A407
A1
35.00°
AA
BB
CC
DD
EE
' - 2
' - 2
' - 2
' - 2
3" 4'
- 3
1/ 4"
50-A302
50-A304
50-A410
50-A409
50-A409
50-A409 1516
50-A409
50-A409
-A1
50-A302
50-A406
50-A40710
10291028 10311030
1017 10151016 10131014
1003A
C14
C1 D
C1C
A
1008A 1008B
1006B
1006A
B
1V 1B
1V1A
C1A
C1 B
A
B
A
50-A201
D
SF21
SF22
SF23
9 1 /2"
2'
- 9
1/ 2"
3A33
4' - 5 1/2"
SF4
SF5
SF6
SF3
SF2
50-A406
50-A406
50-A406
50-A410
Sim
50-A502
50-A502
3 3 3 3 3
3 3
33A
50-A4089
50-A502
50-A502
Sim
50-A502
50-A502
MI
N.
2'
- 0
50-A701
3A 3A
3A
3A 3A
3A
2'
- 0
6'
- 1 1/
2"
9' - 0"
2' - 6"
50-A502
50-A502
50-A502 3 50-A502
50-A502
50-A502
3A
50-A502
50-A502 8 50-A502
50-A502
50-A502
50-A502
50-A502
50-A502
Sim
50-A502
50-A502
7" 7" 12'
-0 1/2
ONE HOUR FIRE BARRIER
TWO HOUR FIRE BARRIER
CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.
N o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
KEY PLAN
05/01/2023ARCHITECTURAL - FLOOR PLAN,
FIRST FLOOR AREA 1
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-A101.1
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
N 1/4" = 1'-0"
ARCHITECTURAL FLOOR PLAN, FIRST FLOOR
GENERAL FLOOR PLAN NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION,
PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR FULL SCOPE OF WORK.
2. ALL DIMENSIONS ARE TO THE FINISH FACE OF PARTITIONS UNLESS OTHERWISE NOTED.
3. ALL NEW CONSTRUCTION WHICH ENGAGES EXISTING SHALL BE JOINED IN A CAREFUL
MANNER BEING PROPERLY ALIGNED AND MEMBERED SO AS TO LEAVE NO EVIDENCE OF
PATCHING OR REPAIR. PATCH TO MATCH ALL EXISTING WALLS, FLOORS, AND CEILINGS
AFFECTED BY NEW CONSTRUCTION.
4. CONTRACTOR SHALL REPAIR AND PATCH ALL EXISTING WALL CONSTRUCTION WHERE
CRACKS, DENTS, HOLES OR OTHER IMPERFECTIONS HAVE OCCURRED AND PREPARE
SMOOTH SURFACE FOR NEW FINISH. ANY DAMAGE TO SUCH AREAS SHALL BE RESTORED TO
A "LIKE-NEW" CONDITION AS NOTED PRIOR TO THE OWNER'S ACCEPTANCE OF THE WORK.
5. PROVIDE SILICONE SEALANT JOINTS AT JUNCTION OF ALL PLUMBING FIXTURES &
COUNTERTOPS TO A WALL SURFACE.
6. DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING WHERE POSSIBLE: ON THE
PULL SIDE OF DOORS WHERE THE HINGE SIDE OF A DOOR FRAME IS PLACED ADJACENT TO
ANY FIXED CONSTRUCTION, LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
7. ALL FINISHED AREAS ADJACENT TO AND INCLUDED IN THE AREAS OF CONSTRUCTION SHALL
BE PROTECTED FROM DUST AND DIRT THROUGH THE USE OF COR APPROVED DUSTPROOF
PROTECTION.
FLOOR PLAN LEGEND
EXISTING PARTITION WALL TO REMAIN.
PROVIDE AND INSTALL NEW WALLS AS INDICATED ON PLAN.
SEE WALL TYPES ON SHEET A301 FOR MORE INFORMATION.
EXISTING DOOR
PROVIDE AND INSTALL DOORS AND FRAMES AS SHOWN.
SEE DOOR SCHEDULE FOR MORE INFORMATION.
NOT INCUDED IN AREA OF WORK
DOOR NUMBER. REFER TO SHEET 50-A601.
WALL TYPE. REFER TO SHEET 50-A300. REFER TO 50-A502 FOR WALL TYPES AT
STEEL COLUMNS.
MEDICAL HEADWALL TYPE. REFER TO SHEET 50-A501.
GLAZING TYPE. REFER TO SHEETS 50-A604/A605.
1A
MH1
SF-1
KEYNOTES
1 PROVIDE CUSTOM MILLWORK.
2 EXISTING CONCRETE COLUMN TO REMAIN. PAINT TO MATCH ADJACANT
WALLS. PROVIDE COLUMN COLLAR TRIM AT CEILING. TYPICAL AT ALL
EXISTING CONCRETE COLUMNS .
3 FIRE EXTINGUISHER CABINET. REFER TO PLAN DETAILS.
4 PROVIDE HAND AND BUMPER RAILS. REFER TO PLAN DETAILS.
5 PROVIDE BUILT-IN CABINETS AND SOLID SURFACE COUNTERTOP.
6 FLOOR DRAIN. SLOPE FLOOR TOWARDS DRAIN AT 1/8" PER FOOT.
REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.
7 VERTICAL BUILDING EXPANSION JOINT.
8 WALL TO CORNER EXPANSION JOINT.
9 WALL TO WALL EXPANSION JOINT.
10 OUTLINE OF CANOPY ABOVE. REFER TO 50-A104.
11 NURSE STATION PLACE HOLDER. MODULAR FURNITURE SYSTEM
PROVIDED AND INSTALLED BY VA.
12 PROVIDE 3 5/8" FURRING AT TRIAGE SIDE OF MASONRY WALL IN LIEU OF
WAITING ROOM SIDE TO ACCOMMODATE PLUMBING.
13 PROVIDE SLOTTED SLIP TRACK DETAIL WHERE NEW WALL ATTACHES
TO EXISTING STRUCTURE. REFER TO DETAIL 2/50-A300.
14 MEDICAL GAS ZONE VALVE BOX. REFER TO MEDICAL GAS DRAWINGS
FOR MORE INFORMATION.
15 PAINT CONCRETE COLUMN TO MATCH ADJACANT WALLS.
0 2' 4' 8'
RATED WALL LEGEND
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
3 4
FF
3.8
II
HH
JJ
GG
50-A401
50-A301
50-A201
CLEAN SUPPLY
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
OIT COMM CLOSET
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
(MENTAL HEALTH)
EXAM/ TREATMENT
(MENTAL HEALTH)
STORAGE
TOILET
(PATIENT/CHILD)
CORRIDOR
C11
1' - 4 1/2"
/1 50-A101.3 CORRIDOR
C9
W1 W1
3A
1 1
ALIGN
1A
3A
10' - 4 3/4" 10' - 4 3/4" 10' - 4 3/4" 10' - 4 3/4"
5' - 11 1/4"
12' - 10 3/4"
FUTURE
ELEVATOR
6"
7' - 6"
2 1 /2"
9'
- 7
0"
0"
0"
1"
9' - 4 1/4"
SEATING AREA
WAITING AREA
COFFEE SHOP
5'
- 6
1/ 2"
10'
MH3
MH3
MH3
MH2
MH2 MH2
MH1
MH1
SF1
SF1
SF1
SF1
50-A302
10591058
1056A 1057A
1'
- 1
1 1 /2"
5'
- 0
13' - 10 1/4"
2'
- 0
3/ 4"
2'
- 0
3/ 4"
9"
50-A410
Sim
EQ EQ EQ EQ
50-A502
50-A502
50-A502
50-A502
ONE HOUR FIRE BARRIER
TWO HOUR FIRE BARRIER
CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.
E
EXISTING CONCRETE COLUMN TO
REMAIN. PAINT TO MATCH
ADJACENT WALLS.
1' - 4 1/4" 1' - 4 1/4"
1'
- 2
1/ 4"
2 1/2" METAL STUDS SPACED
NOT MORE THAN 16" ON
CENTER.
5/8" GYPSUM
WALL BOARD
N o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
KEY PLAN
05/01/2023ARCHITECTURAL - FLOOR PLAN,
FIRST FLOOR AREA 2
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-A101.2
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
N 1/4" = 1'-0"
ARCHITECTURAL FLOOR PLAN, FIRST FLOOR
GENERAL FLOOR PLAN NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION,
PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR FULL SCOPE OF WORK.
2. ALL DIMENSIONS ARE TO THE FINISH FACE OF PARTITIONS UNLESS OTHERWISE NOTED.
3. ALL NEW CONSTRUCTION WHICH ENGAGES EXISTING SHALL BE JOINED IN A CAREFUL
MANNER BEING PROPERLY ALIGNED AND MEMBERED SO AS TO LEAVE NO EVIDENCE OF
PATCHING OR REPAIR. PATCH TO MATCH ALL EXISTING WALLS, FLOORS, AND CEILINGS
AFFECTED BY NEW CONSTRUCTION.
4. CONTRACTOR SHALL REPAIR AND PATCH ALL EXISTING WALL CONSTRUCTION WHERE
CRACKS, DENTS, HOLES OR OTHER IMPERFECTIONS HAVE OCCURRED AND PREPARE
SMOOTH SURFACE FOR NEW FINISH. ANY DAMAGE TO SUCH AREAS SHALL BE RESTORED TO
A "LIKE-NEW" CONDITION AS NOTED PRIOR TO THE OWNER'S ACCEPTANCE OF THE WORK.
5. PROVIDE SILICONE SEALANT JOINTS AT JUNCTION OF ALL PLUMBING FIXTURES &
COUNTERTOPS TO A WALL SURFACE.
6. DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING WHERE POSSIBLE: ON THE
PULL SIDE OF DOORS WHERE THE HINGE SIDE OF A DOOR FRAME IS PLACED ADJACENT TO
ANY FIXED CONSTRUCTION, LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
7. ALL FINISHED AREAS ADJACENT TO AND INCLUDED IN THE AREAS OF CONSTRUCTION SHALL
BE PROTECTED FROM DUST AND DIRT THROUGH THE USE OF COR APPROVED DUSTPROOF
PROTECTION.
FLOOR PLAN LEGEND
EXISTING PARTITION WALL TO REMAIN.
PROVIDE AND INSTALL NEW WALLS AS INDICATED ON PLAN.
SEE WALL TYPES ON SHEET A301 FOR MORE INFORMATION.
EXISTING DOOR
PROVIDE AND INSTALL DOORS AND FRAMES AS SHOWN.
SEE DOOR SCHEDULE FOR MORE INFORMATION.
NOT INCUDED IN AREA OF WORK
DOOR NUMBER. REFER TO SHEET 50-A601.
WALL TYPE. REFER TO SHEET 50-A300. REFER TO 50-A502 FOR WALL TYPES AT
STEEL COLUMNS.
MEDICAL HEADWALL TYPE. REFER TO SHEET 50-A501.
GLAZING TYPE. REFER TO SHEETS 50-A604/A605.
1A
MH1
SF-1
KEYNOTES
1 PROVIDE HAND AND BUMPER RAILS. REFER TO PLAN DETAILS.
2 EXISTING CONCRETE COLUMN TO REMAIN. PAINT TO MATCH
ADJACANT WALLS. PROVIDE COLUMN COLLAR TRIM AT CEILING.
TYPICAL AT ALL EXISTING CONCRETE COLUMNS .
3 WALL TO WALL EXPANSION JOINT.
4 PROVIDE SLOTTED SLIP TRACK DETAIL WHERE NEW WALL
ATTACHES TO EXISTING STRUCTURE. REFER TO DETAIL 2/50-A300.
0 2' 4' 8'
RATED WALL LEGEND
1 1/2" = 1'-0"
COLUMN E-5
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
EE
DD
CC
50-A402
50-A301
50-A4076
TOILET (MENTAL
HEALTH)
EXAM/ TREATMENT
(MENTAL HEALTH)
EXAM/ TREATMENT
(MENTAL HEALTH)
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
(WOMENS HEALTH)
TOILET (PATIENT)
ALCOVE- IMAGING
C5A
RADIOLOGY
ALCOVE- OMNICELL
MEDS
NURSE STATION-
NORTH
POC
-A
.4
W1
W1
SF12
SF13
RADIOLOGY
CONTROL
1046A
W3
1 1
3A
1A
2 1
3A
2' - 2" 7' - 3" 3' - 8 1/2"
4' - 8 1/4"
10' - 0 1/4" 10' - 0 1/4" 10' - 0" 6' - 11 3/4" 4' - 0"
6"
6" 8'
- 0
9'
- 1
1 1 /2"
9'
- 1
1 1 /4"
9" 8'
- 0 1/
4" 9'
- 1 1 1
/4"
13' - 11 1/4" 8' - 0" 10' - 7"
WOMENS
RESTROOM
MENS RESTROOM
CORRIDOR
1C2
ELEVATOR
50P2
ELEVATOR
50P1
ALCOVE
C7A
CORRIDOR
C5
CORRIDOR
C6
CORRIDOR
C7
CORRIDOR
C8
4B
CORRIDOR
C7
3 1 /2"
1'
- 2
3/ 4"
3'
- 5
1/ 4"
9'
- 9
1/ 4"
19' - 5 3/4"
3 3
MH2
MH2
MH1 MH1 MH1 MH1
50-A408
50-A407
50-A40910
50-A409
50-A411
1049 1048
A
A
1048A
1046A
C7B
C7A
N/A
C5
1'
- 7
50-A504
50-A409
C9
6 1 /4"
19' - 5 3/4"
7EQ
EQ
1' - 4 1
/4"
2' - 7"
3' -
1/4
C5
50-A411
50-A40911 50-A409 4
EQ
EQ
50-A40111 12
ONE HOUR FIRE BARRIER
TWO HOUR FIRE BARRIER
CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.
B8
/1 50-A101.2 1
N o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
KEY PLAN
05/01/2023ARCHITECTURAL - FLOOR PLAN,
FIRST FLOOR AREA 3
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-A101.3
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
N 1/4" = 1'-0"
ARCHITECTURAL FLOOR PLAN, FIRST FLOOR, AREA 3
GENERAL FLOOR PLAN NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION,
PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR FULL SCOPE OF WORK.
2. ALL DIMENSIONS ARE TO THE FINISH FACE OF PARTITIONS UNLESS OTHERWISE NOTED.
3. ALL NEW CONSTRUCTION WHICH ENGAGES EXISTING SHALL BE JOINED IN A CAREFUL
MANNER BEING PROPERLY ALIGNED AND MEMBERED SO AS TO LEAVE NO EVIDENCE OF
PATCHING OR REPAIR. PATCH TO MATCH ALL EXISTING WALLS, FLOORS, AND CEILINGS
AFFECTED BY NEW CONSTRUCTION.
4. CONTRACTOR SHALL REPAIR AND PATCH ALL EXISTING WALL CONSTRUCTION WHERE
CRACKS, DENTS, HOLES OR OTHER IMPERFECTIONS HAVE OCCURRED AND PREPARE
SMOOTH SURFACE FOR NEW FINISH. ANY DAMAGE TO SUCH AREAS SHALL BE RESTORED TO
A "LIKE-NEW" CONDITION AS NOTED PRIOR TO THE OWNER'S ACCEPTANCE OF THE WORK.
5. PROVIDE SILICONE SEALANT JOINTS AT JUNCTION OF ALL PLUMBING FIXTURES &
COUNTERTOPS TO A WALL SURFACE.
6. DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING WHERE POSSIBLE: ON THE
PULL SIDE OF DOORS WHERE THE HINGE SIDE OF A DOOR FRAME IS PLACED ADJACENT TO
ANY FIXED CONSTRUCTION, LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
7. ALL FINISHED AREAS ADJACENT TO AND INCLUDED IN THE AREAS OF CONSTRUCTION SHALL
BE PROTECTED FROM DUST AND DIRT THROUGH THE USE OF COR APPROVED DUSTPROOF
PROTECTION.
FLOOR PLAN LEGEND
EXISTING PARTITION WALL TO REMAIN.
PROVIDE AND INSTALL NEW WALLS AS INDICATED ON PLAN.
SEE WALL TYPES ON SHEET A301 FOR MORE INFORMATION.
EXISTING DOOR
PROVIDE AND INSTALL DOORS AND FRAMES AS SHOWN.
SEE DOOR SCHEDULE FOR MORE INFORMATION.
NOT INCUDED IN AREA OF WORK
DOOR NUMBER. REFER TO SHEET 50-A601.
WALL TYPE. REFER TO SHEET 50-A300. REFER TO 50-A502 FOR WALL TYPES AT
STEEL COLUMNS.
MEDICAL HEADWALL TYPE. REFER TO SHEET 50-A501.
GLAZING TYPE. REFER TO SHEETS 50-A604/A605.
1A
MH1
SF-1
KEYNOTES
1 PROVIDE BUILT-IN CABINETS AND SOLID SURFACE COUNTERTOP.
2 EXISTING CONCRETE COLUMN TO REMAIN. PAINT TO MATCH
ADJACANT WALLS. PROVIDE COLUMN COLLAR TRIM AT CEILING.
TYPICAL AT ALL EXISTING CONCRETE COLUMNS .
3 PROVIDE HAND AND BUMPER RAILS. REFER TO PLAN DETAILS.
4 EXISTING TOILET RELOCATED.
5 EXISTING SINKS RELOCATED.
6 REMOVE EXISTING GYPSUM BOARD LAYER. PROVIDE NEW LAYER OF
LEAD LINED GYPSUM BOARD AND LEAD SHIELDING.
7 NURSE STATION PLACE HOLDER. MODULAR FURNITURE SYSTEM
PROVIDED AND INSTALLED BY VA.
8 PROVIDE NEW WALL AND DOOR. PAINT WALL TO MATCH ADJACANT
FINISHES.
0 2' 4' 8'
RATED WALL LEGEND
N 1/4" = 1'-0"
ARCHITECTURAL FLOOR PLAN, FIRST FLOOR, AREA 5
0 2' 4' 8'
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
EE
DD
CC
BB
50-A4046
50-A301
50-A301
SOILED UTILITY
CT
CT CONTROL
PROCEDURE
PROCEDURE
MECHANICAL (E)
ELECTRICAL (E)
BIOMED COMM
CLOSET (E)
113B
EMS SUPPORT
EXAM/ TREATMENT
(ISOLATION)
COLLABORATION
NURSE STATION-
SOUTH
DECONTAMINATION
TOILET (STAFF)
TOILET (ISOLATION
PATIENT)
1036A
CLEAN LINEN
155 SF
ELECTRICAL
NOURISHMENT
AMBULANCE
VESTIBULE
1V2
STORAGE- OXYGEN
-A
.3
50-A407
SF15
SF20
SF19
SF20
W2
3A
3A
1 1 1
3A
3A
3A
1A
1A
1A
4A
4A
4A
4B
3A
14' - 1 3/4"14' - 0"
6'
- 9
13' - 1 3/4"
2' - 0" 10' - 9 3/4"
6 1 /4"
5'
- 1
1 1 /2"
8'
- 2
5 1
/4"
5'
- 4
1/ 4"
9'
- 0
0"
50-A304
CORRIDOR
C3
CORRIDOR
C4
6' - 5" 19' - 5 3/4" 20' - 5 3/4"
1A
1A
5 1 /4"
MH1
9'
- 0
2' - 10"
50-A304
50-A411 79
50-A4082
50-A408
50-A409
50-A104
50-A104
50-AD201
A
A
B
1V 2A
A
1042 1041
1V2B
1064A 1064B
SF15
SF16
50-A504
1 337 50-A504
50-A503
3A
2 2
C5
50-A101.2
ALCOVE
C2A
50-A409 7
50-A40950-A409 4
ONE HOUR FIRE BARRIER
TWO HOUR FIRE BARRIER
CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.
N o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
KEY PLAN
05/01/2023ARCHITECTURAL - FLOOR PLAN,
FIRST FLOOR AREA 4
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-A101.4
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
N 1/4" = 1'-0"
ARCHITECTURAL FLOOR PLAN, FIRST FLOOR
GENERAL FLOOR PLAN NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION,
PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR FULL SCOPE OF WORK.
2. ALL DIMENSIONS ARE TO THE FINISH FACE OF PARTITIONS UNLESS OTHERWISE NOTED.
3. ALL NEW CONSTRUCTION WHICH ENGAGES EXISTING SHALL BE JOINED IN A CAREFUL
MANNER BEING PROPERLY ALIGNED AND MEMBERED SO AS TO LEAVE NO EVIDENCE OF
PATCHING OR REPAIR. PATCH TO MATCH ALL EXISTING WALLS, FLOORS, AND CEILINGS
AFFECTED BY NEW CONSTRUCTION.
4. CONTRACTOR SHALL REPAIR AND PATCH ALL EXISTING WALL CONSTRUCTION WHERE
CRACKS, DENTS, HOLES OR OTHER IMPERFECTIONS HAVE OCCURRED AND PREPARE
SMOOTH SURFACE FOR NEW FINISH. ANY DAMAGE TO SUCH AREAS SHALL BE RESTORED TO
A "LIKE-NEW" CONDITION AS NOTED PRIOR TO THE OWNER'S ACCEPTANCE OF THE WORK.
5. PROVIDE SILICONE SEALANT JOINTS AT JUNCTION OF ALL PLUMBING FIXTURES &
COUNTERTOPS TO A WALL SURFACE.
6. DOOR INSTALLATIONS SHALL COMPLY WITH THE FOLLOWING WHERE POSSIBLE: ON THE
PULL SIDE OF DOORS WHERE THE HINGE SIDE OF A DOOR FRAME IS PLACED ADJACENT TO
ANY FIXED CONSTRUCTION, LOCATE THE DOOR SIDE FRAME OPENING 4" FROM THE FIXED
CONSTRUCTION.
7. ALL FINISHED AREAS ADJACENT TO AND INCLUDED IN THE AREAS OF CONSTRUCTION SHALL
BE PROTECTED FROM DUST AND DIRT THROUGH THE USE OF COR APPROVED DUSTPROOF
PROTECTION.
FLOOR PLAN LEGEND
EXISTING PARTITION WALL TO REMAIN.
PROVIDE AND INSTALL NEW WALLS AS INDICATED ON PLAN.
SEE WALL TYPES ON SHEET A301 FOR MORE INFORMATION.
EXISTING DOOR
PROVIDE AND INSTALL DOORS AND FRAMES AS SHOWN.
SEE DOOR SCHEDULE FOR MORE INFORMATION.
NOT INCUDED IN AREA OF WORK
DOOR NUMBER. REFER TO SHEET 50-A601.
WALL TYPE. REFER TO SHEET 50-A300. REFER TO 50-A502 FOR WALL TYPES AT
STEEL COLUMNS.
MEDICAL HEADWALL TYPE. REFER TO SHEET 50-A501.
GLAZING TYPE. REFER TO SHEETS 50-A604/A605.
1A
MH1
SF-1
KEYNOTES
1 HOSE BIBB. REFER TO PLUMBING DRAWINGS FOR MORE
INFORMATION.
2 REMOVE EXISTING GYPSUM BOARD LAYER. PROVIDE NEW LAYER OF
LEAD LINED GYPSUM BOARD AND LEAD SHIELDING.
3 NURSE STATION PLACE HOLDER. MODULAR FURNITURE SYSTEM
PROVIDED AND INSTALLED BY VA.
4 PROVIDE CUSTOM MILLWORK.
5 EXISTING CONCRETE COLUMN TO REMAIN. PAINT TO MATCH
ADJACANT WALLS. PROVIDE COLUMN COLLAR TRIM AT CEILING.
TYPICAL AT ALL EXISTING CONCRETE COLUMNS .
6 FIRE EXTINGUISHER CABINET. REFER TO PLAN DETAILS.
7 FLOOR DRAIN. SLOPE FLOOR TOWARDS DRAIN AT 1/8" PER FOOT.
REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.
8 PROVIDE HAND AND BUMPER RAILS. REFER TO PLAN DETAILS.
9 FILL-IN EXISTING WALL. MATCH ADJACENT CONSTRUCTION.
10 MEDICAL GAS ZONE VALVE BOX. REFER TO MEDICAL GAS
DRAWINGS FOR MORE INFORMATION.
11 MEDICAL GAS ALARM PANEL. REFER TO MEDICAL GAS DRAWINGS
FOR MORE INFORMATION.
0 2' 4' 8'
RATED WALL LEGEND
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
DOWN
DOWN
K-4368HIG
HCLIFF
C_TO
ILETS
VITREO
US CHINA
K-4368HIG
HCLIFF
C_TO
ILETS
VITREO
US CHINA
N
N
TO
BLDG
F
F
EE
DD
CC
BB
2 3.8 4.6 5.5 6.3
II
HH
JJ
GG
50-A201
50-A201
50-A301
8.5 98.3
50-A301
50-A201
50-A301
50-A303
50-A302
50-A304
50-A304
A1
50-A201
1/ 4"
1'
-0
1/ 4"
1'
-0
1/4" / 1'-0"
1/ 4"
1'
-0
1/ 4"
1'
-0
50-A703
50-A703
50-A703
2' - 0" 9 1/2"
6'
- 8
4'
- 0
8'
- 4
3'
- 1 0 1
/4"
8"
8 3/4"
1' - 3" 1' - 6"
1/ 4"
1'
-0
1/4" / 1'-0"
1/4" / 1'-0"
1/ 4"
/ 1 '-0
1/ 4"
1'
-0
1/4" / 1'-0"
1/8" / 1'-0"
1/4" / 1'-0"
1/4" / 1 '-0"
1/4" / 1 '-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1 '-0"
5/8" / 1'-0"
5/8" / 1'-
0"
50-A702 o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
05/01/2023ARCHITECTURAL - FLOOR PLAN,
SECOND FLOOR, ROOF
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-A102
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
KEYNOTES
1 ROOF DRAIN AND OVERFLOW. REFER TO 8/50-A703 FOR FLASHING.
REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.
2 VENT PIPE. REFER TO PLUMBING DRAWINGS FOR MORE
INFORMATION.
3 MB-1 ROOF ASSEMBLY.
4 EIFS-2 PARAPET WALL ASSEMBLY. REFER TO 1/50-A703.
5 NEW CASEMENT WINDOW. REFER TO EXTERIOR GLAZING SHEET.
6 BUILDING EXPANSION JOINT.
7 OPENING IN ROOF DECK. COORDINATE WITH STRUCTURAL AND
MECHANICAL DRAWINGS.
8 CONCRETE CURB. REFER TO STRUCTURAL DRAWINGS.
0 2' 4' 8'
GENERAL ROOF NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING STRUCTURAL, FIRE
PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR FULL SCOPE OF
WORK.
2. ROOF ASSEMBLIES INCLUDE:
MB-1
• SBS MODIFIED BITUMINOUS MEMBRANE ROOFING
• 1/2" COVER BOARD
• TAPERED INSULATION
• 5" POLISOCYANURATE RIGID INSULATION (R-25)
• CONCRETE SLAB ON METAL DECK
MB-2
• SBS MODIFIED BITUMINOUS MEMBRANE ROOFING
• 1/2" COVER BOARD
• TAPERED INSULATION
• METAL DECK
N 1/8" = 1'-0"
ARCHITECTURAL FLOOR PLAN, SECOND FLOOR
Revisions: Date:
35% SCHEMATIC DESIGN SUBMISSION 8/10/2021
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
Floor 2 73'-8 3/8"
3'
- 0
0"
5 6
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8"
3'
- 0
0"
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8"
3'
- 0
0"
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8"
3'
- 0
0"
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8"
3'
- 0
0"
1'
- 1
0"
2"
1'
- 0
5 6
Floor 1 59'-8 3/8"
Floor 2 73'-8 3/8"
3'
- 0
0"
50-A303
50-A104
50-A104
50-A104
50-A104
-A1
50-A104
3' - 0"
15' - 0"
3' - 0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0" 1/4" / 1'-0"
R 20'-0"
15' - 0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
50-A303
50-A701
5'
- 0
0"
0"
0"
5' - 0"
' - 0
' - 1
1/2
10' - 0"5' - 0" o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
05/01/2023ARCHITECTURAL - CANOPY EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-A104
678-331
19-103
8-
EX
PA
N D
A N
D R
EN
O
VA
TE
E M
ER
G
EN
C
Y D
EP
AR
TM
EN
T B5
-B
ID
S
ET
1/8" = 1'-0"
PARTIAL NORTH ELEVATION - EXTERIOR CANOPY
1/8" = 1'-0"
PARTIAL SOUTH ELEVATION - EXTERIOR CANOPY
1/8" = 1'-0"
EAST ELEVATION - EXTERIOR CANOPY
1/8" = 1'-0"
WEST ELEVATION - EXTERIOR CANOPY
1/8" = 1'-0"
PARTIAL NORTH ELEVATION - EXTERIOR CANOPY
1/8" = 1'-0"
PARTIAL SOUTH ELEVATION - EXTERIOR CANOPY
N 1/8" = 1'-0"
ROOF PLAN - EXTERIOR CANOPY
KEYNOTES
N 1/8" = 1'-0"
REFLECTED CEILING PLAN - EXTERIOR CANOPY
1 MB-2 ROOF ASSEMBLY.
2 ROOF DRAIN AND OVERFLOW. REFER TO 8/50-A703 FOR FLASHING. REFER
TO PLUMBING DRAWINGS FOR MORE INFORMATION.
3 24" ILLUMINATED OUTDOOR METAL CHANNEL LETTER SIGN WITH
CONTINUOUS ENCLOSURE (RACEWAY). REFER TO ELECTRICAL DRAWINGS
FOR MORE INFORMATION.
4 STONE VENEER CANOPY ENCLOSURE. TYPICAL AT EACH COLUMN. REFER
TO EXTERIOR DETAILS FOR MORE INFORMATION.
5 EIFS-3 CANOPY WALL ASSEMBLY.
6 EIFS REVEAL. REFER TO EXTERIOR DETAILS FOR MORE INFORMATION.
7 STRUCTURAL STEEL COLUMN. REFER TO STRUCTURAL DRAWINGS FOR
MORE INFORMATION.
8 COWS TONGUE. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.
0 4' 8' 16' 0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
Revisions: Date:
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #1 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION - #2 12/7/2022
BID SET 05/01/2023
VA FORM 08-6231
FF
4.6 5.5 6.3
II
HH
JJ
GG
50-A301
8.5 98.3
50-A301
50-A303
50-A302
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
(FAST TRACK)
EXAM/ TREATMENT
(FAST TRACK)
HAC
SECURITY STATION
RECEPTION
WAITING
AOD SUPPORT
TRIAGE
TRIAGE
TOILET (STAFF)
STORAGE- AOD
PIT
CONSULT
SOILED UTILITY
EXAM/ TREATMENT
(LOW ACUITY)
1026D
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
EXAM/ TREATMENT
(ISOLATION)
STORAGE- EMS
TOILET (ISOLATION
PATIENT)
1032A
MEDS
VESTIBULE
1V1
EXAM/ TREATMENT
(LOW ACUITY)
1026A
EXAM/ TREATMENT
(LOW ACUITY)
1026B
EXAM/ TREATMENT
(LOW ACUITY)
1026C
EXAM/ TREATMENT
(LOW ACUITY)
1026E
EXAM/ TREATMENT
(LOW ACUITY)
1026F
EXAM/ TREATMENT
(LOW ACUITY)
1026G
CORRIDOR
C2
CORRIDOR
C11
/1 50-AC101.4
1 1
8'-6"
9'-0"
9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"9'-0"9'-0"9'-0"9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0" 8'-9"9'-0"
8'-0"
9'-0"
9'-0"
9'-0"
9'-6"
9'-8"
9'-0"
1 1
9'-0"
9'-0"
9'-0"
2 2 2 2
9'-0" 9'-0" 9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
8'-0"
ANTEROOM
ALCOVE- DRINKING
FOUNTAIN
1001C
CORRIDOR
C1
STAIR
SH2-50
NURSE STATION-
EAST
TOILET (PUBLIC)
1001A
TOILET (PUBLIC)
1001B
CORRIDOR
C12
CORRIDOR
C13
CORRIDOR
C14
CORRIDOR
C3
50-A304
A1
AA
BB
CC
DD
EE
111111
1 1 1 1
50-A302
7'-8"
50-A505
8'-6"
8'-0"
8'-0"
7'-0"
7'-0"
7 87 87 87 87 8
7 8 7 8 7 8 7 8
ONE HOUR FIRE BARRIER
TWO HOUR FIRE BARRIER
CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.
N o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title