Attachment 6 - Structural Drawings.pdf
PDF 12 MB Posted
- Attached to
- Y1DA--Expand and Renovate Emergency Department B50 Minor Construction - Tucson VAMC (VA-24-00001448)
- Solicitation number
- 36c77623r0191
About this file
This document provides details on a federal contract opportunity for expanding and renovating an emergency department at the Tucson Veterans Affairs Medical Center in Arizona. The solicitation number is 36c77623r0191 and is seeking bids to expand and renovate the emergency department located at 3601 South 6th Avenue in Tucson, Arizona 85723. The contracting agency is the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The opportunity type is a solicitation and the description provided indicates the work required includes expanding the existing emergency department building and renovating the interior spaces. No further specifics or requirements are included in this document.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
o n e e ig h th i n c h o n e fo o t th re e i n c h e s o n e fo o t o n e a n d o n e h a lf i n c h e s o n e fo o t o n e i n c h o n e fo o t th re e q u a rt e rs i n c h o n e fo o t o n e h a lf i n c h o n e fo o t th re e e ig h th s i n c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
REVIEW ONLY - NOT FOR CONSTRUCTION
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362 50
05/01/2023GENERAL NOTES EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
JH HL
50-S001
678-331
8-
E X
P A
N D
A N
D R
E N
O V
A T
E E
M E
R G
E N
C Y
D E
P A
R T
M E
N T
B
B
ID
S
E T
GR GENERAL REQUIREMENTS
GR-1 AS USED IN THESE GENERAL NOTES:
"DRAWINGS" MEANS THE LATEST STRUCTURAL DESIGN DRAWINGS, UON.
"SPECIFICATIONS" MEANS THE LATEST PROJECT SPECIFICATIONS, UON.
“CONTRACT DOCUMENTS” IS DEFINED AS THE DESIGN DRAWINGS AND THE SPECIFICATIONS
“SER” IS DEFINED AS THE STRUCTURAL ENGINEER OF RECORD FOR THE STRUCTURE IN ITS FINAL
CONDITION.
“DESIGN PROFESSIONALS” IS DEFINED AS THE OWNER’S ARCHITECT AND SER.
“MEP” INCLUDES, BUT IS NOT LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION.
“CONTRACTOR” IS DEFINED TO INCLUDE ANY OF THE FOLLOWING: GENERAL CONTRACTOR AND THEIR
SUBCONTRACTORS, CONSTRUCTION MANAGER AND THEIR SUBCONTRACTORS, STRUCTURAL STEEL
FABRICATOR OR STRUCTURAL STEEL ERECTOR.
“BASE BUILDING STRUCTURE” IS DEFINED AS THE STRUCTURAL FRAME DESIGNED BY THORNTON
TOMASETTI.
“STRUCTURE IN ITS FINAL CONDITION” MEANS ALL STRUCTURAL ELEMENTS SHOWN ON THE STRUCTURAL
CONTRACT DOCUMENTS ARE INSTALLED AND COMPLETELY CONNECTED AND INSPECTED WITH NO
OUTSTANDING NON-COMPLIANCE ISSUES.
“DELEGATED DESIGN” MEANS A SCOPE OF WORK THAT MEETS PERFORMANCE CRITERIA ESTABLISHED IN THE CONTRACT DOCUMENTS AND IS TO BE COMPLETED BY THE CONTRACTOR’S LICENSED ENGINEER.
“SERVICE LEVEL” LOADS ARE DEFINED AS NOMINAL OR UNFACTORED LOADS TO BE COMBINED USING
ALLOWABLE STRESS LOAD COMBINATIONS
“STRENGTH LEVEL” LOADS ARE DEFINED AS FACTORED LOADS TO BE COMBINED USING STRENGTH DESIGN
LOAD COMBINATIONS
GR-2 THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THE STRUCTURAL WORK WITH THE ARCHITECTURAL, CIVIL, MEP CONTRACT DOCUMENTS, AS WELL AS ANY OTHER APPLICABLE TRADES.
GR-3 THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE UNTIL THE CONSTRUCTION OF
THE STRUCTURE REACHES ITS FINAL CONDITION.
GR-4 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND REMOVAL OF TEMPORARY BRACING AND CONSTRUCTION SUPPORTS, FOR NEW AND EXISTING STRUCTURES, AS NECESSARY TO COMPLETE THE PROJECT. NO PORTION OF THE PROJECT WHILE UNDER CONSTRUCTION IS INTENDED TO BE STABLE IN THE ABSENCE OF THE CONTRACTOR’S TEMPORARY SUPPORTS AND BRACES. CONTRACTOR SHALL RETAIN A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED TO
DESIGN TEMPORARY BRACING AND CONSTRUCTION SUPPORTS.
GR-5 LATERAL LOAD RESISTANCE AND STABILITY OF THE STRUCTURE IN ITS FINAL CONDITION IS PROVIDED BY STEEL MOMENT FRAMES AND LATERAL STABILITY OF OTHER ELEMENTS IS PROVIDED THROUGH FLOOR
SLABS.
GR-6 THE SPECIFICATIONS ARE AN INTEGRAL PART OF THE CONTRACT DOCUMENTS AND SHALL BE USED IN
CONJUNCTION WITH THE STRUCTURAL DRAWINGS.
GR-7 THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AND COORDINATE WITH THE STRUCTURAL DRAWINGS, ARCHITECTURAL DRAWINGS, DRAWINGS FROM OTHER CONSULTANTS, PROJECT
SHOP DRAWINGS AND FIELD CONDITIONS.
GR-8 IN CASES OF CONFLICT BETWEEN DRAWINGS AND/OR SPECIFICATIONS AND OTHER DISCIPLINES OR EXISTING CONDITIONS, CONTRACTOR SHALL NOTIFY THE DESIGN PROFESSIONALS AND OBTAIN CLARIFICATION PRIOR
TO BIDDING AND PROCEEDING WITH WORK.
GR-9 APPLY DETAILS, SECTIONS, AND NOTES ON THE DRAWINGS WHERE CONDITIONS ARE SIMILAR TO THOSE
INDICATED BY DETAIL, DETAIL TITLE OR NOTE.
GR-10 ONLY USE DIMENSIONS INDICATED ON THE DRAWINGS. DO NOT SCALE DRAWINGS.
GR-11 ASSUME EQUAL SPACING BETWEEN ESTABLISHED DIMENSIONS, IF NOT INDICATED ON DRAWINGS.
GR-12 CENTERLINES OF COLUMNS AND FOUNDATIONS COINCIDE WITH GRID LINE INTERSECTIONS, UON.
GR-13 CENTERLINES OF GRADE BEAMS AND WALLS COINCIDE WITH CENTERLINES OF FOUNDATIONS, UON.
GR-14 CENTERLINES OF FRAMING MEMBERS COINCIDE WITH COLUMN CENTERLINES, UON.
GR-15 THE CONTRACTOR SHALL PROTECT EXISTING FACILITIES, STRUCTURES AND UTILITIES FROM DAMAGE.
GR-16 THE CONTRACTOR SHALL VERIFY THAT CONSTRUCTION LOADS DO NOT EXCEED THE CAPACITY OF THE
STRUCTURE AT THE TIME THE LOAD IS APPLIED.
GR-17 THE CONTRACTOR SHALL COORDINATE THE BOTTOM OF BASE PLATE ELEVATIONS WITH THE AS-BUILT TOP
OF SUPPORT ELEVATIONS.
GR-18 THE CONTRACTOR SHALL VERIFY ALL OPENING SIZES AND LOCATIONS WITH OTHER DISCIPLINES. THE DRAWINGS DO NOT SHOW ALL OPENINGS REQUIRED. ADDITIONAL OPENINGS, BLOCKOUTS AND SLEEVES MAY BE REQUIRED BY OTHER DISCIPLINES AND SHALL BE CONSTRUCTED USING THE TYPICAL DETAILS AND/OR THE CRITERIA INDICATED ON THE DRAWINGS. OPENINGS REQUIRED BUT NOT SHOWN ON THE STRUCTURAL
DRAWINGS MUST BE APPROVED BY THE SER.
GR-19 ELEVATIONS INDICATED ON STRUCTURAL DRAWINGS ARE BASED ON A PROJECT DATUM INDICATED ON THE
ARCHITECTURAL / CIVIL DRAWINGS.
GR-20 SEE ARCHITECTURAL, CIVIL, MEP, AND VERTICAL TRANSPORTATION, CONTRACT DOCUMENTS FOR ADDITIONAL INFORMATION RELATING TO THE COORDINATION OF STRUCTURAL COMPONENTS INCLUDING, BUT
NOT LIMITED TO:
CIVIL:
PROJECT DATUM
SITING OF BUILDING GRID LINES WITH RESPECT TO CITY BENCHMARKS
SITE PREPARATION
BACKFILLING MATERIALS AND REQUIREMENTS
PAVING AND SITE ELEMENTS OUTSIDE OF BUILDING ENVELOPE
NEW AND EXISTING SITE UTILITIES
ARCHITECTURAL:
PLAN DIMENSIONS AND PROJECT DATUM
SLAB EDGE DIMENSIONS
FINISH ELEVATIONS
WATERPROOFING AND DAMP-PROOFING DETAILS
RAMP GEOMETRY, PITS, SLAB SLOPES AND DEPRESSIONS
EMBEDMENTS, INSERTS, BLOCKOUTS, ETC.
EXACT OPENING SIZES FOR PIPES, DUCTS, ETC.
CONCRETE FINISHES AND TOPPING SLABS
CONCRETE CURBS AND HOUSEKEEPING PADS
INTERIOR NON-STRUCTURAL MASONRY PARTITIONS
FIRE RATINGS
MEP:
PIPE AND DUCT SIZES FOR OPENING AND SLEEVE COORDINATION
FLOOR DRAINS
UNDERFLOOR AND PERIMETER DRAINAGE SYSTEMS
EQUIPMENT CURBS
CONDUITS AND EMBEDMENTS IN WALLS AND SLABS
VERTICAL TRANSPORTATION:
INSERTS, HANGERS, TRENCHES, PITS, CONDUITS IN WALLS AND SLABS
EQUIPMENT SUPPORT, ELEVATOR DIVIDER BEAMS, EMBEDMENTS, AND ANCHOR RODS
CD CODES AND DESIGN CRITERIA
CD-1 PERFORM ALL CONSTRUCTION IN CONFORMANCE WITH THE BUILDING AND DESIGN CODES REFERENCED WITHIN THESE DOCUMENTS. THE PROJECT DOCUMENTS REFER TO THE FOLLOWING CODES AND STANDARDS, UON:
INTERNATIONAL BUILDING CODE, 2018 EDITION WITH CITY OF TUCSON AMENDMENTS
STRUCTURAL CONCRETE:
"BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE"
THE AMERICAN CONCRETE INSTITUTE (ACI 318-14)
MASONRY:
"BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES"
THE AMERICAN CONCRETE INSTITUTE (TMS 402-2016/ACI 530-16/ASCE 5-16)
"SPECIFICATION FOR MASONRY STRUCTURES"
THE AMERICAN CONCRETE INSTITUTE (TMS 602-2016/ACI 530.1-16/ASCE 6-16)
STRUCTURAL STEEL:
"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”, (AISC 360-16) CONFORMING TO THE PROVISIONS OF LOAD RESISTANCE FACTOR DESIGN, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC-LRFD)
DEPARTMENT OF VETERANS AFFAIRS STRUCTURAL DESIGN MANUAL FOR HOSPITAL PROJECTS DATED
FEBRUARY 1, 2014.
DEPARTMENT OF VETERANS AFFAIRS PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL DATED
OCTOBER 1, 2020 (REVISED SEPTEMBER 1, 2021).
DEPARTMENT OF VETERANS AFFAIRS SEISMIC DESIGN REQUIREMENTS DATED NOVEMBER 1, 2019 (REVISED
MAY 1, 2020)
UFC 4-023-03 DESIGN OF BUILDINGS TO RESIST PROGRESSIVE COLLAPSE DATED JULY 14, 2009 (REVISED
NOVEMBER 1, 2016)
CD-2 LIVE LOADS (SERVICE LEVEL):
LEVEL 1 100 PSF
2,000 LB POINT LOAD OVER 2.5 FT X 2.5 FT AREA
LEVEL 2 100 PSF
2,000 LB POINT LOAD OVER 2.5 FT X 2.5 FT AREA
FUTURE LEVEL 3 100 PSF
2,000 LB POINT LOAD OVER 2.5 FT X 2.5 FT AREA
FUTURE ROOF 150 PSF
LOW ROOF 20 PSF
CD-3 SUPERIMPOSED DEAD LOADS (SERVICE LEVEL):
TYPICAL 20 PSF
CD-4 RISK CATEGORY: IV
CONSTRUCTION TYPE TYPE II (111)
CD-5 SNOW LOADS (SERVICE LEVEL):
FLAT ROOF SNOW LOAD (Pf): 0 PSF GROUND SNOW LOAD (Pg) 0 PSF SNOW EXPOSURE FACTOR (Ce): 1.0 SNOW LOAD IMPORTANCE FACTOR (Is): 1.2 THERMAL FACTOR (Ct): 1.0
SNOW DRIFTING PER CODE
CD-6 WIND LOAD DESIGN DATA (STRENGTH LEVEL):
MAIN WIND FORCE RESISTING SYSTEM
BASIC WIND SPEED, V 115 MPH
EXPOSURE B
INTERNAL PRESSURE COEFFICIENT ± 0.18
DESIGN BASE SHEAR (CURRENT) 30 KIP E-W/60 KIP N-S
DESIGN BASE SHEAR (FUTURE) 85 KIP E-W/150 KIP N-S
COMPONENT AND CLADDING DESIGN PRESSURES a= 6’-6”
EFFECTIVE WIND AREA= 20 SF WALL= 25.5 PSF WALL END ZONE= 30.5 PSF
ROOF EFFECTIVE WIND AREA = 20 SF
ROOF= 40 PSF ROOF EDGE = 53 PSF ROOF CORNER= 70 PSF
CD-7 SEISMIC LOAD DESIGN DATA (STRENGTH LEVEL):
SEISMIC IMPORTANCE FACTOR (Is) 1.5 Ss 0.270 g S1 0.083 g SDS 0.285 g SD1 0.133 g
SITE CLASS D
SEISMIC DESIGN CATEGORY C
LATERAL SYSTEM DESCRIPTION STEEL ORDINARY MOMENT FRAMES
RESPONSE MODIFICATION FACTOR (R) 3.5
ANALYSIS PROCEDURE DESCRIPTION EQUIVALENT LATERAL FORCE
DESIGN BASE SHEAR (CURRENT) 110 KIPS
DESIGN BASE SHEAR (FUTURE) 185 KIPS
CD-9 IN CASES WHERE THE CONTRACTOR DETERMINES THAT SUSPENDED OR FLOOR MOUNTED EQUIPMENT LOADS EXIST WHICH EXCEED DESIGN LOADS INDICATED ON CONTRACT DOCUMENTS, CONTRACTOR SHALL SUBMIT LOAD DATA TO DESIGN PROFESSIONALS FOR REVIEW PRIOR TO PROCEEDING WITH WORK.
CD-10 DISTRIBUTE THE MAXIMUM LOAD HUNG FROM ANY STRUCTURAL MEMBER FOR DUCTWORK, PIPING ETC OVER THE MEMBER’S TRIBUTARY AREA IN A WAY THAT THE MEP DESIGN SUPERIMPOSED DEAD LOADS LISTED IN CONTRACT DOCUMENTS ARE NOT EXCEEDED. THE CONTRACTOR SHALL COORDINATE THE LOADS OF ALL TRADES AND PROVIDE ADDITIONAL SUPPORT OR DISTRIBUTION FRAMING AS REQUIRED TO ACHIEVE THE
ALLOWABLE LOAD DISTRIBUTION.
CD-11 STRUCTURAL COMPONENTS ARE NOT DESIGNED FOR VIBRATING EQUIPMENT. MOUNT VIBRATING EQUIPMENT
ON VIBRATION ISOLATORS.
CD-12 SERVICEABILITY
LIVE LOAD DEFLECTION IS LESS THAN L/360
LONG-TERM TOTAL DEFLECTION IS LESS THAN L/240
EXTERIOR EDGE BEAMS HAVE BEEN DESIGNED TO LIMIT LIVE LOAD MIDSPAN VERTICAL DEFLECTION TO 1/360
OF THE SPAN OR 3/8", WHICHEVER IS LESS.
EXTERIOR EDGE BEAMS HAVE BEEN DESIGNED TO LIMIT DEAD PLUS SUPERIMPOSED DEAD LOAD MIDSPAN
VERTICAL DEFLECTION TO 1/240 OF THE SPAN OR 3/8”, WHICHEVER IS LESS.
LATERAL DRIFT DUE TO WIND LOADS IS LESS THAN OR EQUAL TO H/400
CD-13 VIBRATION OF THE NEW FLOOR FRAMING HAS BEEN ANALYZED ACCORDING TO AISC DESIGN GUIDE 11 – VIBRATIONS OF STEEL-FRAMED STRUCTURAL SYSTEMS DUE TO HUMAN ACTIVITY (2ND EDITION), WITH THE
FOLLOWING CRITERIA:
ALL ELEVATED LEVELS:
SURGERY FACILITIES
MAXIMUM FOOTFALL RATE: 2.1 HZ
DAMPING RATIO: 0.02
TOLERANCE LIMIT: 4,000 MIPS
CD-14 CONNECTIONS OF SYSTEMS DESIGNED BY CONTRACTOR’S ENGINEER SUCH AS, BUT NOT LIMITED TO, CLADDING, STAIRS, ELEVATORS, ESCALATORS, PRECAST, AND MEP LOADS ARE ASSUMED TO IMPOSE
VERTICAL AND/OR HORIZONTAL LOADS ON THE BASE BUILDING STRUCTURAL MEMBERS WITHOUT
GENERATING TORSION IN THE SUPPORTING STRUCTURAL MEMBERS. CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING ALL SUPPLEMENTARY BRACING MEMBERS AS REQUIRED TO PREVENT TORSION
ON THE BASE BUILDING STRUCTURE.
CD-15 FOR FIRE RATING AND FIREPROOFING ASSEMBLY EVALUATIONS, CONSIDER THE FOLLOWING ASSEMBLIES
RESTRAINED: COMPOSITE WIDE-FLANGE STEEL FRAMING
CONSIDER ALL OTHER ASSEMBLIES UNRESTRAINED.
CD-16 THERE HAVE BEEN NO LOAD RESTRICTION FACTORS APPLIED TO THE STRUCTURAL DESIGN FOR THE
PURPOSES OF SELECTING FIREPROOFING ASSEMBLIES.
DE DEMOLITION
DE-1 THE CONTRACTOR IS FULLY RESPONSIBLE FOR THE MEANS AND METHODS OF DEMOLITION AND THE INTEGRITY AND STABILITY OF THE EXISTING STRUCTURE DURING DEMOLITION UNTIL THE WORK IS COMPLETED. THE CONTRACTOR SHALL PROVIDE SHORING IN REQUIRED LOCATIONS WHERE EXISTING
CONSTRUCTION TO REMAIN WILL BE AFFECTED BY DEMOLITION. CONTRACTOR SHALL RETAIN A
PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED TO DESIGN SHORING.
DE-2 THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS TO ANY STRUCTURAL ELEMENTS WHICH ARE TO REMAIN AND THAT HAVE BEEN DAMAGED DURING THE DEMOLITION PROCESS TO THE COMPLETE SATISFACTION OF THE OWNER. THE REPAIRS SHALL BE AT NO EXPENSE TO THE OWNER. ALL REPAIR WORK SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED AND
SUBMITTED TO THE SER FOR REVIEW AND APPROVAL PRIOR TO COMMENCING REPAIR WORK.
DE-3 ALL EXISTING FRAMING IS INDICATED FOR REFERENCE ONLY AND IS TO BE FIELD VERIFIED BY THE CONTRACTOR. VERIFY THE EXACT EXTENT OF DEMOLITION AT THE SITE. DETERMINE THE NATURE AND EXTENT OF DEMOLITION THAT WILL BE NECESSARY BY COMPARING THE CONTRACT DOCUMENTS WITH THE EXISTING CONSTRUCTION. IMMEDIATELY NOTIFY THE DESIGN PROFESSIONALS OF ANY INCONSISTENCIES.
DE-4 THE CONTRACTOR SHALL USE THE STRUCTURAL CONTRACT DOCUMENTS IN CONJUNCTION WITH THE ARCHITECTURAL AND MEP DEMOLITION CONTRACT DOCUMENTS. IN THE EVENT OF CONFLICTS, THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DESIGN PROFESSIONALS.
DE-5 THE CONTRACTOR SHALL USE QUALIFIED, EXPERIENCED PERSONNEL FOR DEMOLITION AND REMOVAL OPERATIONS. PERFORM DEMOLITION AND REMOVAL OPERATIONS IN A CAREFUL AND ORDERLY MANNER TO PREVENT HAZARDS TO PERSONS, DAMAGE TO PROPERTY, AND THE SPREADING OF DUST AND DEBRIS.
DE-6 DO NOT PERMIT PORTIONS OF THE STRUCTURE TO FALL NOR DEBRIS TO DROP EXCEPT BY METHODS WHICH
WILL ENSURE INTEGRITY OF THE STRUCTURE.
DE-7 PRIOR TO THE START OF WORK, VERIFY THAT THE SCOPE OF DEMOLITION INDICATED ON THE CONTRACT DOCUMENTS SHALL NOT DAMAGE, CUT OR DISRUPT SERVICE OF ANY MECHANICAL SYSTEM, ELECTRICAL
SYSTEM OR UTILITY EMBEDDED IN THE EXISTING STRUCTURE.
DE-8 DO NOT REMOVE MORE OF THE EXISTING STRUCTURE THAN INDICATED ON CONTRACT DOCUMENTS. DO NOT
DAMAGE, MAR, CUT OR DEFACE THE REMAINING STRUCTURE OR MATERIALS TO BE REUSED.
DE-9 THE CONTRACTOR SHALL INCLUDE IN HIS BID THE COST OF REMOVING DEMOLISHED MATERIALS FROM THE
SITE IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES, AND REGULATIONS.
DE-10 WHERE NEW OPENINGS IN EXISTING CONCRETE SLABS OR WALLS ARE TO BE CREATED, THE DEMOLITION CONTRACTOR SHALL CORE HOLES AT THE OUTSIDE CORNERS OF THE NEW OPENING PRIOR TO DEMOLITION.
SAW-CUT AND DEMOLISH SLAB OR WALL ONLY AFTER THE INSTALLATION OF ALL REQUIRED NEW STRUCTURAL FRAMING AND/OR REINFORCEMENT IN PLAN OR SECTION, UON. SAW CUTTING SHALL BE STRAIGHT AND SHALL NOT EXTEND INTO EXISTING SLAB OR WALL TO REMAIN NOR BEYOND THE HOLES
CORED AT THE CORNERS OF THE NEW OPENING.
DI DELEGATED DESIGN ITEMS
DI-1 THE CONTRACTOR SHALL EMPLOY OR RETAIN A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THIS PROJECT IS LOCATED TO DESIGN AND DETAIL DELEGATED DESIGN ITEMS TO MEET THE PERFORMANCE AND DESIGN CRITERIA ESTABLISHED AS PART OF THE BASE BUILDING STRUCTURE INDICATED IN THE
CONTRACT DOCUMENTS INCLUDING BUT NOT LIMITED TO:
COLD-FORMED METAL FRAMING
PATIENT LIFTS
MECHANICAL / ELECTRICAL / PLUMBING EQUIPMENT ANCHORAGE
SU SUBMITTALS
SU-1 THE CONTRACTOR IS TO REVIEW EACH SUBMITTAL PRIOR TO FORWARDING TO DESIGN PROFESSIONALS.
THE CONTRACTOR IS TO STAMP EACH SUBMITTAL VERIFYING THAT THE FOLLOWING IS ADDRESSED:
1. THE SHOP DRAWING IS REQUESTED.
2. THE SHOP DRAWING IS BASED ON THE LATEST DESIGN.
3. THE DESIGN PROFESSIONALS’ COMMENTS FROM ANY PREVIOUS SUBMITTALS ARE ADDRESSED.
4. THE WORK IS COORDINATED AMONG ALL CONSTRUCTION TRADES.
5. REVISIONS FROM PREVIOUS SUBMITTALS ARE CLEARLY MARKED BY CIRCLING OR CLOUDS.
6. SUBMITTAL IS COMPLETE.
7. SUBMITTAL DOES NOT INCLUDE SUBSTITUTION REQUEST.
8. SUBMITTAL SHALL INCLUDE A STAMP INDICATING PROJECT NAME AND LOCATION, SUBMITTAL NUMBER, SPECIFICATION SECTION NUMBER.
THE SER SHALL RETURN, WITHOUT COMMENT, SUBMITTALS WHICH THE CONTRACTOR HAS NOT STAMPED OR
WHICH DO NOT MEET THE ABOVE REQUIREMENTS.
SU-2 THE SER’S REVIEW OF SUBMITTALS SHALL BE FOR GENERAL CONFORMANCE WITH THE DESIGN INTENT. NO
WORK SHALL BE STARTED WITHOUT SUCH REVIEW.
SU-3 FOR COMPONENTS THAT REQUIRE ENGINEERING BY THE CONTRACTOR, PROVIDE A NOTE ON EACH SHOP DRAWING, WRITTEN AND SIGNED BY THE SUPPLIER'S ENGINEER, INDICATING THAT THE SHOP DRAWING IS IN
CONFORMANCE WITH THE CALCULATIONS OF THE CONTRACTOR'S ENGINEER.
SU-4 THE FOLLOWING ITEMS REQUIRE SUBMITTALS FOR STRUCTURAL REVIEW AS OUTLINED IN THE
SPECIFICATIONS:
033000 S CALC CONCRETE FORMWORK
033000 S CONCRETE REINFORCING LAYOUT
033000 CONCRETE MIX DESIGNS
033000 S CONCRETE CONSTRUCTION JOINT LAYOUT
042000 S MASONRY REINFORCEMENT LAYOUT
051200 S STRUCTURAL STEEL
051200 S CALC STRUCTURAL STEEL CONNECTIONS
051200 S SHEAR STUD LAYOUT
053600 S CALC STEEL COMPOSITE DECK
053100 S CALC STEEL ROOF DECK
316326 S CAISSON LAYOUT AND SIZE
S = SHOP DRAWINGS REQUIRED
CALC = SUPPORTING CALCULATIONS REQUIRED, SEALED AND SIGNED BY A PROFESSIONAL ENGINEER
LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED.
SU-5 THE ITEMS IN THIS SECTION REFER TO LOADS IMPOSED BY CONTRACTOR DESIGNED SYSTEMS, SPECIFICALLY:
COLD-FORMED METAL FRAMING
EXTERIOR CLADDING SYSTEMS
ARCHITECTURAL ORNAMENTATION (FLAGPOLES, BANNERS, MASTS, ETC.)
ELEVATOR REACTIONS
WHERE CONTRACTOR LOADS IMPOSED DO NOT EXCEED AND/OR CONNECTION CONDITIONS DO NOT DIFFER FROM WHAT IS INDICATED IN THE STRUCTURAL DRAWINGS, SUBMIT FOR RECORD A LETTER SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED STATING
THE FOLLOWING:
“THE CONTRACTOR DESIGNED SYSTEM HAS BEEN DESIGNED TO IMPOSE LOADS ON THE BASE BUILDING STRUCTURE THAT ARE WITHIN THE LOAD LIMITS AND AT THE LOCATIONS INDICATED ON THE STRUCTURAL
DRAWINGS.”
WHERE CONTRACTOR LOADS IMPOSED FOR THE FOLLOWING ITEMS EXCEED AND/OR CONNECTION
CONDITIONS DIFFER FROM WHAT IS SHOWN IN THE STRUCTURAL DRAWINGS, SUBMIT FOR APPROVAL TO SER LOADS IMPOSED ON THE PRIMARY STRUCTURAL FRAME DUE TO THE DEAD, LIVE, AND WIND/SEISMIC LOADS
INDICATED ON THE CONTRACT DOCUMENTS.
SUBMITTAL SHALL LIST THE DESIGN LOADS USED AND BE SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED. SUBMITTAL SHALL INCLUDE LOCATION, MAGNITUDE AND DIRECTION OF UNFACTORED IMPOSED LOADS, GRAPHICALLY REPRESENTED IN THEIR APPROPRIATE LOCATIONS ON A COPY OF THE CONTRACT DOCUMENT STRUCTURAL FRAMING PLANS OR ELEVATIONS AS APPROPRIATE. DETAIL REFERENCES IN THE CONNECTIONS APPLICABLE AT EACH
LOCATION SHALL BE NOTED ON THE SUBMITTAL DRAWINGS.
FOR EXTERIOR WALL ASSEMBLIES, THE LOADS IMPOSED SUBMITTAL SHALL BE COMPREHENSIVE INDICATING THE LOADS IMPOSED ON THE BASE BUILDING STRUCTURE AND SHALL INCLUDE THE REACTIONS BASED ON THE ACTUAL LOADS OF THE ENTIRE ASSEMBLY, INCLUDING BUT NOT LIMITED TO GLAZING, CLADDING, METAL
STUD BACKUP, AND MULLIONS.
FOR MEP SYSTEMS, THE LOADS IMPOSED SUBMITTAL SHALL BE COMPREHENSIVE INDICATING THE LOADS IMPOSED ON THE BASE BUILDING STRUCTURE AND SHALL INCLUDE THE REACTIONS BASED ON THE ACTUAL LOADS OF THE ENTIRE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEM, INCLUDING
BUT NOT LIMITED TO PIPING, DUCTS, ELECTRICAL RACEWAYS, AND EQUIPMENT WEIGHTS.
A SUBSTITUTION REQUEST MAY BE REQUIRED WHERE CONTRACTOR LOADS IMPOSED EXCEED AND/OR
CONNECTION CONDITIONS DIFFER FROM THE BASIS OF DESIGN.
FN FOUNDATIONS
FN-1 THE FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL REPORT BY TERRACON DATED JAN 21, 2022
(TERRACON PROJECT # 63215060) AND ADDENDUM NO. 1 DATED FEBRUARY 4, 2022.
FN-2 FOUNDATIONS HAVE BEEN DESIGNED BASED ON THE FOLLOWING DESIGN VALUES FROM THE GEOTECHNICAL
REPORT (SERVICE LEVEL):
MINIMUM CAISSON DIAMETER 2 FT
ALLOWABLE END BEARING PRESSURE: 15,350 PSF (END BEARING BELOW 15 FT BELOW GRADE)
ALLOWABLE SKIN FRICTION: 300 PSF (BETWEEN 8 AND 15 FT BELOW GRADE)
700 PSF (BELOW 15 FT BELOW GRADE)
CAISSON SHALL BE DRILLED TO A MINIMUM OF 15 FT BELOW FINISHED GRADES OR 5 FT BELOW EXISTING
FILLS, WHICHEVER IS DEEPER.
CAISSON AXIAL AND LATERAL CAPACITY HAS BEEN REDUCED WHERE CAISSONS ARE CONSTRUCTED IN
GROUPS AS REQUIRED PER THE ABOVE REFERENCED GEOTECHNICAL REPORT.
ACCORDING TO THE ABOVE REFERENCED GEOTECHNICAL REPORT, SETTLEMENT OF THE CAISSONS
DESIGNED ACCORDING TO THE ABOVE VALUES ARE ANTICIPATED TO BE LESS THAN 1 INCH.
DESIGN VALUES SHALL BE FIELD VERIFIED BY QUALIFIED GEOTECHNICAL ENGINEER RETAINED BY THE
ARCHITECT.
FN-3 THE CONTRACTOR SHALL VERIFY FOUNDATION INSTALLATION AND CONSTRUCTION IS IN CONFORMANCE
WITH THE RECOMMENDATIONS OUTLINED IN THE GEOTECHNICAL REPORT.
FN-4 CONTRACTOR SHALL BE RESPONSIBLE TO ADEQUATELY PROTECT ALL EXCAVATION. WHERE NECESSARY, SHEET AND SHORE THE EXCAVATION WITH ALL REQUIRED TIEBACKS AND BRACING AS DETERMINED BY
CONTRACTOR’S ENGINEER.
FN-5 PROVIDE BRACING FOR ALL WALLS PRIOR TO BACKFILLING, WHERE BACKFILLING IS REQUIRED.
THIS BRACING SHALL REMAIN IN PLACE UNTIL ALL SLABS AND BEAMS FRAMING INTO WALL HAVE BEEN
PLACED AND HAVE ATTAINED 100% OF THEIR DESIGN STRENGTH.
FN-6 DO NOT BACKFILL AGAINST CANTILEVER RETAINING WALLS UNTIL THE CONCRETE HAS ATTAINED 100% OF
ITS DESIGN STRENGTH.
CM CONCRETE MATERIALS
CM-1 CONCRETE STRENGTH SHALL MEET THE FOLLOWING 28-DAY COMPRESSIVE STRENGTHS (f' c), UON:
CAISSONS 4,000 PSI
CAISSON CAPS 4,000 PSI
GRADE BEAMS 4,000 PSI
NON-SHRINK GROUT 8,000 PSI
SLAB ON GRADE 5,000 PSI
CONCRETE ON STEEL DECK 4,000 PSI
CONCRETE HOUSEKEEPING PADS, AND FILL SLABS 4,000 PSI
CM-2 PROVIDE NORMALWEIGHT CONCRETE WITH CURED DENSITY OF 145 +/- 5 PCF, AND AGGREGATE CONFORMING TO ASTM C33, UON. WHERE INDICATED, PROVIDE LIGHTWEIGHT CONCRETE WITH CURED DENSITY OF
112+/-3 PCF AND AGGREGATE CONFORMING TO ASTM C330.
CM-3 THE USE OF CALCIUM CHLORIDE AND OTHER CHLORIDE CONTAINING AGENTS IS PROHIBITED. THE USE OF RECYCLED CONCRETE IS PROHIBITED. PLACEMENT WITHIN AND CONTACT BETWEEN ALUMINUM ITEMS, INCLUDING ALUMINUM CONDUIT, AND CONCRETE IS PROHIBITED.
CM-4 ALL CAST-IN-PLACE CONCRETE WILL EXPERIENCE DIFFERING VARIATIONS OF CRACKING. ANY ELEMENT EXPOSED TO DIRECT WEATHER AND/OR TEMPERATURE VARIATIONS DURING CONSTRUCTION OR IN THE FINAL CONDITION IS TO BE TREATED AND REGULARLY MAINTAINED TO PREVENT PROPAGATION OF CRACKS AND WATER PENETRATION. THE CONTRACTOR SHALL DEVELOP A REGULAR MAINTENANCE PROGRAM AND SUBMIT
IT TO THE OWNER.
Revisions: Date:
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION 12/07/2022
BID SET 05/01/2023
5/1/23
BID SET
VA FORM 08-6231
Revisions: Date:
BID SET 05/01/2023
5/1/23 o n e e ig h th i n c h o n e fo o t th re e i n c h e s o n e fo o t o n e a n d o n e h a lf i n c h e s o n e fo o t o n e i n c h o n e fo o t th re e q u a rt e rs i n c h o n e fo o t o n e h a lf i n c h o n e fo o t th re e e ig h th s i n c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
REVIEW ONLY - NOT FOR CONSTRUCTION
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362 50
05/01/2023GENERAL NOTES EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
JH HL
50-S002
678-331
8-
E X
P A
N D
A N
D R
E N
O V
A T
E E
M E
R G
E N
C Y
D E
P A
R T
M E
N T
B
B
ID
S
E T
RE CONCRETE REINFORCEMENT
RE-1 ALL CONCRETE SHALL INCLUDE REINFORCEMENT. IF REINFORCEMENT IS NOT SPECIFICALLY INDICATED ON
THE DRAWINGS VERIFY WITH THE SER.
RE-2 REINFORCEMENT SHALL CONFORM TO THE FOLLOWING STANDARDS AND MATERIAL PROPERTIES UON:
DEFORMED BARS: ASTM A615 GRADE 60
WELDABLE DEFORMED BARS: ASTM A706
EPOXY COATED DEFORMED BARS: ASTM A615 / A775
WELDED WIRE REINFORCEMENT ASTM A1064
EPOXY COATED WELDED WIRE REINFORCEMENT ASTM A1064 / A884
RE-3 DETAIL REINFORCEMENT BASED ON THE PROJECT REQUIREMENTS, ACI-318 AND ACI-315, UON.
RE-4 WHERE A 90-DEG, 135 –DEG OR 180-DEG HOOK IS GRAPHICALLY INDICATED, PROVIDE CORRESPONDING ACI
STANDARD HOOKS UON.
RE-5 DOWELS SHALL MATCH SIZE AND SPACING OF MAIN REINFORCEMENT UON.
RE-6 REINFORCEMENT SHALL HAVE CONCRETE PROTECTION (CLEAR COVER) PER ACI 318 UNLESS OTHERWISE
INDICATED ON THE DRAWINGS.
RE-7 LAP REINFORCEMENT ONLY AT LOCATIONS AS SPECIFICALLY DETAILED ON THE DRAWINGS EXCEPT REINFORCEMENT MARKED AS CONTINUOUS CAN BE SPLICED AT LOCATIONS DETERMINED BY CONTRACTOR
USING TENSION LAP SPLICES (LTS). SEE LAP SPLICE AND EMBEDMENT SCHEDULE.
RE-8 UNLESS OTHERWISE NOTED ALL LAP SPLICES ARE TO BE TENSION LAP SPLICES PER LAP SPLICE AND
EMBEDMENT SCHEDULE.
RE-9 PROVIDE MECHANICAL SPLICES FOR BARS LARGER THAN #11 OR WHERE INDICATED. PROVIDE TENSILE, PRE-
QUALIFIED, WELDED OR THREADED MECHANICAL SPLICES UON.
RE-10 LAP WELDED WIRE REINFORCEMENT TWO PANEL SPACINGS, UON.
RE-11 PROVIDE LAP SPLICE LOCATIONS AS FOLLOWS, UON:
A. GRADE BEAM / WALL (TOP HORIZONTAL REINFORCEMENT): AT CENTER OF SPAN
B. GRADE BEAM / WALL (BOTTOM HORIZONTAL REINFORCEMENT): AT SUPPORTS
C. WALL INSIDE FACE (VERTICAL REINFORCEMENT): AT SUPPORT
D. WALL OUTSIDE FACE (VERTICAL REINFORCEMENT): AT SUPPORT
E. UNLESS OTHERWISE NOTED TERMINATE BARS AT DISCONTINUOUS ENDS WITH STANDARD HOOKS.
RE-12 PROVIDE EPOXY COATED REINFORCEMENT AND ACCESSORIES IN AREAS OF DIRECT EXPOSURE TO THE
ENVIRONMENT, CHEMICALS, OR DE-ICING FOR THE AREAS INDICATED ON THE DRAWINGS.
CJ CONCRETE CONSTRUCTION JOINTS
CJ-1 PROVIDE CONSTRUCTION JOINTS IN ACCORDANCE WITH ACI-318. SUBMIT SHOP DRAWINGS SHOWING PROPOSED CONSTRUCTION JOINT LOCATIONS, DETAILS AND THE PLACEMENT SEQUENCE FOR THE SER'S
APPROVAL PRIOR TO PROCEEDING WITH WORK.
CJ-2 UNLESS SPECIFICALLY SHOWN ON THE DRAWINGS, HORIZONTAL CONSTRUCTION JOINTS SHALL NOT BE PERMITTED IN FOOTINGS, PILE CAPS, MAT FOUNDATIONS, GRADE BEAMS, BEAMS, UPTURNED BEAMS, SLABS, AND WALLS WITHOUT PRIOR WRITTEN APPROVAL FROM THE SER BEFORE CONSTRUCTION.
CJ-3 PLACE VERTICAL CONSTRUCTION JOINTS TO PROVIDE A 60 FT MAXIMUM LENGTH OF CONCRETE PLACEMENT
AND LOCATE AS FOLLOWS:
A. BEAMS AND GRADE BEAMS: WITHIN THE MIDDLE THIRD OF THE CLEAR SPAN AVOIDING LAP SPLICES, SUBJECT TO SER APPROVAL.
CJ-4 PROVIDE CONTINUOUS WATERSTOPS AT ALL CONSTRUCTION JOINTS EXPOSED TO SOIL OR WATER, AS DESCRIBED IN THE SPECIFICATIONS AND WHERE INDICATED IN THE ARCHITECTURAL DOCUMENTS.
MA MASONRY
MA-1 LOAD BEARING, NON-LOAD BEARING, AND BACKUP WALL CONCRETE MASONRY CONSTRUCTION SHALL
CONFORM TO THE FOLLOWING MATERIAL STANDARDS:
CONCRETE MASONRY UNITS: ASTM C90,NORMALWEIGHT (135 PCF) (MINIMUM NET AREA COMPRESSIVE
STRENGTH 2800 PSI FOR USE WITH TYPE S OR M MORTAR OR 3050 PSI FOR
USE WITH TYPE N MORTAR)
MORTAR: ASTM C270, TYPE S, M OR N
MORTAR USAGE
(UON ON DRAWINGS): USE TYPE S OR M MORTAR WHEN MASONRY IS IN DIRECT CONTACT WITH
SOIL; USE TYPE S MORTAR FOR ALL EXTERIOR AND INTERIOR LOAD-BEARING
WALLS; USE TYPE N MORTAR FOR ALL EXTERIOR AND INTERIOR NON-LOAD-
BEARING WALLS
GROUT: ASTM C476
REINFORCEMENT: ASTM A615, GRADE 60
JOINT REINFORCEMENT: ASTM A951, TRUSS OR LADDER TYPE
EXTERIOR JT REINF: GALVANIZE PER ASTM A153
INTERIOR JT REINF:
TYPICAL GALVANIZE PER ASTM A641
RELATIVE HUMIDITY >75% GALVANIZE PER ASTM A153
ADHESIVE ANCHORS: HILTI HIT-HY 270
MA-2 THE MINIMUM COMPRESSIVE STRENGTH OF THE MASONRY (f' m) SHALL BE 2,000 PSI, UON ON DRAWINGS, DETERMINED BY THE UNIT STRENGTH METHOD IN ACCORDANCE WITH THE ABOVE REFERENCED
SPECIFICATIONS.
MA-3 CALCIUM CHLORIDE SHALL NOT BE USED IN MORTAR OR GROUT.
MA-4 LAY MASONRY UNITS IN RUNNING BOND UON WITH UNITS DESIGNED TO ALIGN WITH WEBS IN EACH COURSE.
MA-5 ALL CELLS WITH REINFORCEMENT SHALL BE GROUTED SOLID. ALL CELLS WHERE MASONRY IS IN CONTACT
WITH SOIL SHALL BE GROUTED SOLID.
MA-6 GROUT MINIMUM OF ONE (1) CELL WITH REINFORCEMENT AT EACH SIDE OF ALL OPENINGS. SEE DRAWINGS
FOR ADDITIONAL REINFORCEMENT REQUIREMENTS.
SS STRUCTURAL STEEL
SS-1 STEEL MATERIALS SHALL CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS UNLESS OTHERWISE
NOTED ON THE CONTRACT DOCUMENTS
ASTM A6 ROLLED W SHAPES AND CHANNELS: ASTM A572 OR A992, MIN YIELD STRENGTH 50 KSI
ANGLES FOR TRUSSES AND BRACES: ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI
MISCELLANEOUS ANGLES: ASTM A36, MIN YIELD STRENGTH 36 KSI
HOLLOW STRUCTURAL SECTIONS: ASTM A500 GRADE C, MIN YIELD STRENGTH 46 KSI FOR
ROUND AND 50 KSI FOR RECTANGULAR HSS
PLATES: ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI
SS-2 CONNECTION MATERIAL SHALL CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS OR AS NEEDED FOR
CONNECTION DESIGN:
ANGLES: ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI UON
WTs: ASTM A572 OR A992, MIN YIELD STRENGTH 50 KSI
PLATES: ASTM A572 OR A529, MIN YIELD STRENGTH 50 KSI UON
BOLTS: ASTM F3125 GRADES A325 AND F1852 OR A490 AND F2280 OR AS INDICATED IN DETAILS
NUTS: ASTM A563
WASHERS: ASTM F436
ANCHOR RODS: ASTM F1554 GRADE 55 WITH WELDABILITY SUPPLEMENT S1, UON
HEADED STUDS ASTM A108, GRADE 1010 THROUGH 1020 HEADED STUD TYPE, COLD-FINISHED CARBON
STEEL, AWS D1.1, TYPE B 3/4” DIAMETER UON
WELD ELECTRODES: MIN TENSILE STRENGTH 70 KSI
SS-3 WHERE NO CAMBER IS INDICATED, FABRICATE BEAMS SO THAT ANY NATURAL CAMBER IS UPWARD AFTER
ERECTION.
SS-4 SPLICES SHALL BE ALLOWED ONLY AT LOCATIONS SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS
UNLESS APPROVED OTHERWISE BY THE SER IN WRITING.
SS-5 FOR STEEL MEMBERS AND EMBEDMENTS EXPOSED TO WEATHER, PROVIDE HOT-DIPPED GALVANIZED FINISH
OR APPROVED ZINC RICH EXTERIOR COATING SYSTEM.
SS-6 PROVIDE HOLES IN ALL STEEL AS REQUIRED TO PREVENT ANY ACCUMULATION OF WATER. ALL PENETRATIONS THROUGH MAIN MEMBERS SHALL NOT EXCEED 1 1/8" DIA. AND SHALL BE GROUND SMOOTH.
THESE DRAINS MUST BE KEPT CLEAN AND OPEN.
SS-7 SHOW ALL COPES, HOLES, OPENINGS AND MODIFICATIONS REQUIRED IN STRUCTURAL STEEL MEMBERS FOR ERECTION OR THE WORK OF OTHER TRADES ON THE SHOP DRAWINGS FOR APPROVAL BY THE DESIGN
PROFESSIONALS.
SS-8 FIELD MODIFICATION OF STRUCTURAL STEEL IS PROHIBITED WITHOUT PRIOR WRITTEN APPROVAL OF THE
DESIGN PROFESSIONALS.
SC STRUCTURAL STEEL CONNECTIONS
SC-1 ALL STEEL DETAILS AND CONNECTIONS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”, AISC-LOAD AND RESISTANCE FACTOR DESIGN.
SC-2 ALL CONNECTIONS INDICATED ON STRUCTURAL DRAWINGS HAVE BEEN COMPLETELY DESIGNED.
SC-3 DETAILS INDICATED ON DRAWINGS DO NOT SHOW ERECTION AIDS. PROVIDE ERECTION AIDS AS REQUIRED
AND REMOVE THEM AFTER WORK IS COMPLETE.
SC-4 ALTERNATE CONNECTIONS TO THOSE SHOWN ON DRAWINGS WILL BE CONSIDERED AS A SUBSTITUTION
REQUEST. SEE PROJECT SPECIFICATIONS.
SC-5 FOR CONNECTION DETAILING, SET CONNECTION WORK POINT AT INTERSECTION OF MEMBER CENTERLINES, UON.
SC-6 CONNECTION DESIGN FORCES INDICATED ON THE DRAWINGS ARE FACTORED UON.
SC-7 USE NO MORE THAN TWO BOLT DIAMETERS, ALL BOLTS OF THE SAME DIAMETER SHALL BE OF THE SAME
GRADE, SKIP ONE SIZE BETWEEN DIAMETERS. BOLTS FOR THIS PROJECT SHALL BE:
3/4” DIAMETER F3125 GRADE A325 OR F1852 OR 1” DIAMETER F3125 GRADE A490 OR F2280
SC-8 BEAM CONNECTION DESIGN NOTES:
SEE PLANS AND ELEVATIONS FOR BEAM REACTIONS AND MOMENTS. IF NO BEAM REACTION OR MOMENT IS SHOWN, CONTRACTOR SHALL NOTIFY THE DESIGN PROFESSIONALS AND OBTAIN CLARIFICATION PRIOR TO
BIDDING AND PROCEEDING WITH WORK.
ALL BEAM REACTIONS, AXIAL FORCES AND MOMENTS SHOWN ACT CONCURRENTLY. UON, BEAM REACTIONS ACT IN GRAVITY DIRECTION WHILE AXIAL FORCES AND MOMENTS ARE TO BE CONSIDERED REVERSIBLE.
WHERE NO AXIAL FORCE IS SHOWN, ALL BEAM CONNECTIONS HAVE BEEN DESIGNED FOR A MINIMUM AXIAL
FORCE EQUAL TO 5% OF FACTORED DEAD LOAD PLUS LIVE LOAD VERTICAL BEAM SHEAR.
EXCEPT WHERE “SNUG TIGHT” INSTALLATION IS SPECIFICALLY PERMITTED ON DRAWINGS OR “SLIP CRITICAL” DETAILING IS REQUIRED, ALL HIGH STRENGTH BOLTS SHALL BE INSTALLED AS FULL PRETENSIONED BOLTS.
AT A MINIMUM ALL BOLTED MOMENT AND AXIAL CONNECTIONS SHALL HAVE PRETENSIONED BOLTS IN STANDARD HOLES. SLIP CRITICAL FAYING SURFACES ARE ONLY REQUIRED WHERE SPECIFIED IN DETAILS.
BOLTED MOMENT CONNECTIONS AT CANTILEVERS AND BACKSPANS SHALL USE SLIP CRITICAL BOLTS.
DO NOT USE OVERSIZED OR SLOTTED HOLES FOR ANY CONNECTIONS UNLESS SPECIFICALLY INDICATED ON
THE DRAWINGS OR APPROVED IN WRITING BY THE SER.
SC-9 ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF THE STRUCTURAL WELDING CODE, ANSI/AWS D1.1, LATEST EDITION. ALL WELD SIZES SHALL BE THE LARGER OF THE SIZE REQUIRED BY CONNECTION FORCES, THE MINIMUM SIZE PER ANSI/AWS D1.1, OR 3/16 INCH MINIMUM FILLET WELD UON. ANY WELD SIZES SHOWN ON THE DESIGN DRAWINGS ARE CONSIDERED EFFECTIVE WELD SIZES AND SHALL BE INCREASED IN
ACCORDANCE WITH AWS AS REQUIRED BY GAPS OR SKEWS BETWEEN COMPONENTS.
SC-10 USE RUNOFF TABS AT ALL BEVEL AND COMPLETE JOINT PENETRATION WELDS. REMOVE RUNOFF TABS BY
NEAT CUTS AFTER WELD IS COMPLETED. GRIND SMOOTH WHERE REQUIRED BY DETAIL.
SC-11 WHERE REQUIRED BY DETAIL REMOVE WELD BACK UP BARS AND GRIND SMOOTH AFTER WELD IS
COMPLETED.
SD STEEL DECK GENERAL REQUIREMENTS
SD-1 THE MANUFACTURE AND ERECTION OF STEEL DECK AND ITS ANCHORAGE SHALL, AT A MINIMUM, BE IN ACCORDANCE WITH "DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS" OF THE STEEL DECK INSTITUTE (SDI), CURRENT EDITION AND "SPECIFICATIONS FOR DESIGN OF LIGHT GAGE COLD FORMED STEEL STRUCTURAL MEMBERS" AS PUBLISHED BY THE AMERICAN IRON AND STEEL INSTITUTE (AISI), CURRENT EDITION.
SD-2 CONFIGURE ALL STEEL DECK USING THREE SPAN CONTINUOUS LAYOUTS WHEREVER POSSIBLE.
SD-3 CONFIGURE ALL STEEL DECK AS SHOWN ON THE DRAWINGS.
DK STEEL COMPOSITE DECK
DK-1 COMPOSITE DECK AND FORM DECK SHALL CONFORM TO THE FOLLOWING STANDARDS AND MATERIAL
PROPERTIES:
ASTM A653-HOT-DIPPED GALVANIZED CONFORMING TO ASTM A924 G60,
OR
ASTM A1008, GRADE C WITH PHOSPHATE TREATED AND BAKED ON RUST-INHIBITIVE PAINT
FABRICATE STEEL DECK UNITS AND ACCESSORIES FROM STEEL SHEET CONFORMING TO ASTM A653
STRUCTURAL QUALITY GRADE 33, WITH A MINIMUM YIELD STRENGTH OF 33 KSI.
DK-2 FASTEN COMPOSITE FLOOR DECK UNITS AS FOLLOWS:
A. TO THE STEEL FRAMEWORK AT ENDS OF UNITS AND AT ALL INTERMEDIATE SUPPORTS: BY PUDDLE WELDS
NOT LESS THAN 3/4 INCH DIAMETER SPACED AT 12 INCHES ON CENTER MAXIMUM, UON. WHERE PRESENT, A HEADED STUD CAN REPLACE A PUDDLE WELD.
B. AT SIDE LAPS OF ADJACENT UNITS BETWEEN SUPPORTS AT INTERVALS NOT EXCEEDING 24 INCHES ON
CENTER UON.
DK-3 COMPOSITE FLOOR DECK HANGER TABS LOADS SHALL NOT EXCEED [60] LBS PER HANGER TAB. IN ADDITION LOADS ON HANGERS SHALL BE DISTRIBUTED IN SUCH A MANNER THAT THE TRIBUTARY LOADS FOR EACH
HANGER SHALL NOT EXCEED 5 POUNDS PER SQUARE FOOT.
DK-4 ALL STEEL BEAMS SUPPORTING COMPOSITE DECK OR CONCRETE SLABS SHALL HAVE 3/4 INCH DIAMETER HEADED SHEAR STUDS. SEE PLAN FOR STUD LAYOUT. DISTRIBUTE STEEL STUDS UNIFORMLY OVER BEAM
SPAN UNLESS OTHERWISE NOTED ON DRAWINGS.
DK-5 HEADED SHEAR STUDS SHALL EXTEND A MINIMUM OF 1 ½ INCHES ABOVE THE TOP OF STEEL DECK WITH A
MINIMUM CLEAR COVER OF ½ INCH FROM THE TOP OF SLAB.
DK-6 COMPOSITE DECKS ARE TO BE POURED-TO-THICKNESS OR AS INDICATED ON THE DRAWINGS.
RD STEEL ROOF DECK
RD-1 STEEL ROOF DECK SHALL CONFORM TO THE FOLLOWING STANDARDS AND MATERIAL PROPERTIES:
STEEL FOR DECK ASTM A653, MINIMUM YIELD STRENGTH OF 33 KSI
HOT-DIP GALVANIZING ASTM A653 G60
ROOF DECK SHALL BE HOT-DIP GALVANIZED, UON
RD-2 PROVIDE STEEL ROOF DECK WITH DEPTH AND MINIMUM GAGE INDICATED ON DRAWINGS. PROVIDE
ANCHORAGE TO SUPPORTING MEMBERS AS INDICATED ON DRAWINGS.
RD-3 ROOF DECK AND ITS ANCHORAGE TO SUPPORTING MEMBERS SHALL MEET THE FOLLOWING MINIMUM
FASTENING REQUIREMENTS
A. AT ENDS OF UNITS AND AT ALL INTERMEDIATE SUPPORTS: BY PUDDLE WELDS NOT LESS THAN 5/8 INCH
DIAMETER SPACED NOT MORE THAN 12 INCHES ON CENTER MAX.
B. SIDE LAPS OF ADJACENT UNITS: SHALL BE FASTENED BY SIDE SEAM WELDING OR SIDELAP SCREWS
SPACED PER MANUFACTURERS ENGINEERED CALCULATIONS WITH A MAXIMUM SPACING OF 24 INCHES ON
CENTER. ARC SEAM WELDS SHALL BE A MINIMUM OF 1-1/2 INCH BY 1/2 INCH.
RD-4 NO LOADS SHALL BE HUNG DIRECTLY FROM STEEL ROOF DECK WITHOUT PRIOR WRITTEN APPROVAL OF THE
DECK SUPPLIER AND REVIEW BY THE SER.
RD-5 DECKING CONTRACTOR SHALL COORDINATE DECK OPENING SIZES AND LOCATIONS FROM ARCHITECTURAL AND MEP CONTRACT DOCUMENTS, PROVIDE HEADER MEMBERS OR REINFORCEMENT AS REQUIRED BY TYPICAL DETAILS EVEN IF NOT SHOWN ON THE PLANS, AND SUBMIT PROPOSED OPENINGS THROUGH
SLAB/DECK FOR REVIEW BY THE DESIGN PROFESSIONALS.
SI SPECIAL INSPECTIONS
SI-1 FOR SCHEDULE OF SPECIAL TESTING AND/OR INSPECTIONS, SEE SHEET S003
AC ARCHITECTURAL CLADDING
AC-1 TYPICAL DETAILS INDICATE GENERAL CRITERIA FOR ASSUMED CONNECTIONS OF ARCHITECTURAL CLADDING TO BASE BUILDING STRUCTURE. PROVIDE DESIGNS THAT MEET INDICATED CRITERIA AND CONFORM TO LISTED CODES AND STANDARDS. REFER TO SUBMITTALS SECTION IN THESE GENERAL NOTES FOR
ADDITIONAL REQUIREMENTS.
PA POST-INSTALLED ANCHORS
PA-1 ADHESIVE ANCHOR SYSTEMS USED FOR DESIGN:
ADHESIVE: HILTI HIT-HY 200
THREADED ROD: HILTI HAS OR
THREADED ROD: HILTI HIT-Z
OVERHEAD AND/OR CONSTANT TENSION ADHESIVE ANCHOR INSTALLATIONS NOT SHOWN ON THE DRAWINGS SHALL NOT BE PERMITTED UNLESS EACH CONDITION IS REVIEWED AND APPROVED IN WRITING BY THE SER.
PA-2 PROOF TESTING OF ADHESIVE ANCHORS SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. UNLESS NOTED OTHERWISE, ADHESIVE ANCHOR PROOF TENSION LOADS SHALL BE PER
THE ADHESIVE ANCHOR PROOF SCHEDULES.
PA-3 FIELD DRILLED EXPANSION ANCHOR SYSTEMS USED FOR DESIGN:
HILTI KWIK BOLT TZ2
PA-4 PROOF TESTING OF EXPANSION ANCHORS SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. UNLESS NOTED OTHERWISE, EXPANSION ANCHOR PROOF TORQUE LOADS SHALL BE PER
THE EXPANSION ANCHOR PROOF SCHEDULES.
PA-5 FIELD DRILLED THREADED SCREW ANCHOR SYSTEMS USED FOR DESIGN:
HILTI KH-EZ
PA-6 ALTERNATIVE SYSTEM EQUIVALENT TO OR EXCEEDING THE PROPERTIES OF THE SYSTEMS ABOVE WILL BE
CONSIDERED AS A SUBSTITUTION REQUEST. SEE PROJECT SPECIFICATIONS.
PA-7 ANCHORS ARE TO BE MINIMUM 3/4” DIAMETER WITH A MINIMUM EMBEDMENT OF 6", UON.
PA-8 INSTALL ANCHORS TO MEET THE REQUIREMENTS INDICATED IN THE CONTRACT DOCUMENTS AND THE
CURRENT MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS (MPII).
PA-9 LOCATE, BY NON-DESTRUCTIVE MEANS, AND AVOID ALL EXISTING REINFORCEMENT PRIOR TO INSTALLATION OF ANCHORS. IF EXISTING REINFORCING LAYOUT PROHIBITS THE INSTALLATION OF ANCHORS AS INDICATED ON THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DESIGN PROFESSIONALS.
PA-10 INSTALL ANCHORS IN SOLID MASONRY OR IN HOLLOW MASONRY THAT HAS BEEN GROUTED SOLID AT LEAST
ONE COURSE ABOVE TO ONE COURSE BELOW THE ANCHOR, UON.
PA-11 SEE PROJECT SPECIFICATIONS FOR POST-INSTALLED ANCHOR INSPECTION REQUIREMENTS.
ABBREVIATION DESCRIPTION
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LP LOW POINT
LSH LONG SLOTTED HOLE
LW LIGHTWEIGHT
LWC LIGHTWEIGHT CONCRETE
M MOMENT
MATL MATERIAL
MAX MAXIMUM
MC MOMENT CONNECTION(S)
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL,
PLUMBING, FIRE PROTECTION
MEZZ MEZZANINE
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
NW NORMAL WEIGHT
NWC NORMALWEIGHT CONCRETE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OH OPPOSITE HAND
OPNG(S) OPENING(S)
OPP OPPOSITE
OSL OUTSTANDING LEG
PC PIECE
PCY POUNDS PER CUBIC YARD
PERP PERPENDICULAR
PG PLATE GIRDER
PJP PARTIAL JOINT PENETRATION
PL PLATE
PRC PRECAST
PRLL PARALLEL
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT OR POST-TENSION(ED)
OR (ING)
RAD RADIUS
REF REFERENCE
REINF REINFORCE(D) (ING) OR (MENT)
REQD REQUIRED
S&T SHRINKAGE AND
TEMPERATURE
SCHED SCHEDULE(D)
SDL SUPERIMPOSED DEAD LOAD
SECT SECTION
SER STRUCTURAL ENGINEER OF
RECORD
SF SQUARE FOOT (FEET)
SFRS SEISMIC FORCE RESISTING
SYSTEM
SHT SHEET
SIM SIMILAR
SOG SLAB ON GRADE
SP SPACE
SPEC(S) SPECIFICATION(S)
STD STANDARD
STL STEEL
STR STRUCTURE
STRCTL STRUCTURAL
SYM SYMMETRICAL
T TENSION
T&B TOP AND BOTTOM
T/ TOP OF
TEMP TEMPERATURE OR
TEMPORARY
TEN TENSION
THK THICK OR THICKNESS
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V SHEAR
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WD WOOD
WP WORK POINT
WPFG WATERPROOFING
WS WATERSTOP
WWR WELDED WIRE
REINFORCEMENT
ABBREVIATION DESCRIPTION
ADDL ADDITIONAL
ADJ ADJACENT
ALT ALTERNATE
APPRX APPROXIMATE
ARCH ARCHITECT OR
ARCHITECTURAL
B/ BOTTOM OF
B/B BACK TO BACK
BAL BALANCE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRDG BRIDGING
BRG BEARING
BTWN BETWEEN
C COMPRESSION
C/C CENTER TO CENTER
CIP CAST-IN-PLACE
CJP COMPLETE JOINT
PENETRATION
CL CENTER LINE
CLR CLEAR OR CLEARANCE
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMP COMPRESSION
CONC CONCRETE
CONN CONNECTION(S)
CONST CONSTRUCTION
CONT CONTINUOUS
db REINFORCING BAR DIAMETER
DBL DOUBLE
DCW DEMAND CRITICAL WELD
DEG DEGREE(S)
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM(S) DIMENSION(S)
DL DEAD LOAD
DWG(S) DRAWING(S)
DWL DOWEL(S)
EA EACH
ECC ECCENTRICITY
EE EACH END
EF EACH FACE
EL ELEVATION
ELEC ELECTRICAL
ENGR ENGINEER
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXP EXPANSION
EXST, (E) EXISTING
EXT EXTERIOR
F/F FACE TO FACE
FIN FINISH(ED)
FLR FLOOR
FND FOUNDATION
FP FIREPROOF(ING)
FS FAR SIDE
FTG FOOTING
GA GAGE, GAUGE
GALV GALVANIZED
GB GRADE BEAM
GEN GENERAL
GR GRADE
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
HT HEIGHT
ID INSIDE DIAMETER
IF INSIDE FACE
INFO INFORMATION
INT INTERIOR
INTRM INTERMEDIATE
JST(S) JOIST(S)
JT JOINT
K KIPS (1,000 POUNDS)
KLF KIP PER LINEAR FOOT
KSF KIP PER SQUARE FOOT
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
Revisions: Date:
65% DESIGN DEVELOPMENT 11/29/2021
65% DESIGN DEVELOPMENT RESUBMISSION 02/28/2022
95% CONSTRUCTION DOCUMENTS SUBMISSION 06/30/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION 10/7/2022
100% CONSTRUCTION DOCUMENTS SUBMISSION 12/07/2022
BID SET 05/01/2023
5/1/23
BID SET
VA FORM 08-6231
Revisions: Date:
Required Verification and Inspection of Post-Installed Concrete Anchors
2. Mechanical Anchor Systems
1. Adhesive Anchor Systems
a. Preparation of pre-drilled holes and installation of anchors.
a. Preparation of pre-drilled holes and installation of anchors.
---- X Manufacturer's Requirements
1704.13(3)
---- X Manufacturer's Requirements
1704.13(3)
Required Special Inspection and Tests of Concrete Construction
1. Inspect reinforcement, and verify placement. ___ X
ACI 318 Ch. 20, 25.2, 25.3, 26.5.1-26.5.3
1908.4
2. Reinforcing bar welding if used due to field fixes:
a. Verify weldability of reinforcing bars other than
ASTM A 706;
b. Inspect single-pass fillet welds, maximum 5/16"; and
c. Inspect all other welds.
AWS D1.4
ACI 318: 26.5.4
4. Inspect anchors post-installed in hardened concrete members.
a. Adhesive anchors installed in horizontally or upwardly inclined orientations to resist sustained tension loads.
b. Mechanical anchors and adhesive anchors not defined in 4.a. X
ACI 318: 17.8.2.4
5. Verify use of required design mix. X ___ ACI 318: Ch. 19, 26.4.3, 26.4.4 1904.1, 1904.2, 1908.2, 1908.3
6. Prior to concrete placement, fabricate specimens for strength tests, perform slump and air content tests, and determine the temperature of the concrete.
X
____ ASTM C 172
ASTM C 31
ACI 318: 26.4.5, 26.12
1908.10
7. Inspect concrete and shotcrete placement for proper application techniques.
X ACI 318: 26.4.5
1908.6, 1908.7, 1908.8
8. Verify maintenance of specified curing temperature and techniques.
X ACI 318: 26.4.7-26.4.9 1908.9
3. Inspect anchors cast in concrete
X
X
___ ACI 318: 17.8.2
Required Verification and Inspection of Steel Construction Other Than Structural Steel
2. Inspection of welding:
1. Material verification of cold-formed steel deck:
a. Identification marking to conform to ASTM standards specified in the approved construction documents.
b. Manufacturer's certified test reports.
a. Cold -formed steel deck:
1) Floor and roof deck welds.
---- X
---- X
---- X
Applicable ASTM material standards
AWS D1.3
Required Verification and Inspection of Structural Steel Construction
MINIMUM INSPECTION
Frequency
Continuous Periodic Reference for CriteriaVerification and Inspection
MINIMUM INSPECTION
Frequency
Continuous Periodic Reference for CriteriaVerification and Inspection IBC Reference
MINIMUM INSPECTION
Frequency
Continuous Periodic Reference for CriteriaVerification and Inspection IBC Reference
Required Special Inspections and Tests of Soils
2. Verify excavations are extended to proper depth and have reached proper material
1. Verify materials below shallow foundations are adequate to achieve the design bearing capacity
---- X 1705.6
MINIMUM INSPECTION
Frequency
Continuous Periodic Reference for CriteriaVerification and Inspection IBC Reference
---- X 1705.6
3. Perform classification and testing of compacted fill materials
---- X 1705.6
4. Verify use of proper materials, densities and lift thicknesses during placement and compaction of compacted fill.
----X 1705.6
5. Prior to placement of compacted fill, inspect subgrade and verify that site has been prepared properly.
---- X 1705.6
STATEMENT OF SPECIAL INSPECTIONS - STRUCTURAL
9. Inspect formwork for shape, location and dimensions of the concrete member being formed.
X ACI 318: 26.10.1(b)
X
X
X
ACI 318: 17.8.2
1. Welding procedure specifications (WPSs) available
2. Manufacturer certifications for welding consumables available
3. Material identification (type/grade)
4. Welder identification system1
5. Fit-up of groove welds (including joint geometry)
a. Joint preparation
b. Dimensions (alignment, root opening, root face, bevel)
c. Cleanliness (condition of steel surfaces)
d. Tacking (tack weld quality and location)
e. Backing type and fit (if applicable)
6. Configuration and finish of access holes
7. Fit-up of fillet welds
a. Dimensions (alignment, gaps at root)
b. Cleanliness (condition of steel surfaces)
c. Tacking (tack weld quality and location)
8. Check welding equipment
PRIOR TO WELDING - MINIMUM INSPECTION
Inspection Type
QC QA
Reference for CriteriaVerification and Inspection
IBC
Reference
AISC 360 Table N5.4-1 1705.2P
O
O
O
O
O ----
1. Use of qualified welders
2. Control and handling of welding consumables
a. Packaging
b. Exposure control
3. No welding over cracked tack welds
4. Environmental conditions
a. Wind speed within limits
b. Precipitation and temperature
5. WPS followed
a. Settings on welding equipment
b. Travel speed
c. Selected welding materials
d. Shielding gas type/flow rate
e. Preheat applied
f. Interpass temperature maintained (min./max.)
g. Proper position (F, V, H, OH)
6. Welding techniques
a. Interpass and final cleaning
b. Each pass within profile limitations
c. Each pass meets quality requirements
DURING WELDING - MINIMUM INSPECTION
Inspection Type
QC QA
Reference for CriteriaVerification and Inspection
IBC
Reference
AISC 360 Table N5.4-2 1705.2
O
O
O
O
1. Welds cleaned
2. Size, length and location of welds
3. Welds meet visual acceptance criteria
a. Crack prohibition
b. Weld/base-metal fusion
c. Crater cross section
d. Weld profiles
e. Weld size
f. Undercut
g. Porosity
4. Arc strikes
5. k-area1
6. Backing removed and weld tabs removed (if required)
7. Repair activities
8. Document acceptance or rejection of welded joint or member
AFTER WELDING - MINIMUM INSPECTION
Inspection Type
QC QA
Reference for CriteriaVerification and Inspection
IBC
Reference
AISC 360 Table N5.4-3 1705.2O
P P
P P
P P
P P
P P
P P
1. Manufacturer’s certifications available for fastener materials
2. Fasteners marked in accordance with ASTM requirements
3. Proper fasteners selected for the joint detail (grade, type, bolt length if threads are to be excluded from shear plane)
4. Proper bolting procedure selected for joint detail
5. Connecting elements, including the appropriate faying surface condition and hole preparation, if specified, meet applicable requirements
6. Pre-installation verification testing by installation personnel observed and documented for fastener assemblies and methods used
7. Proper storage provided for bolts, nuts, washers and other fastener components
PRIOR TO BOLTING - MINIMUM INSPECTION
Inspection Type
QC QA
Reference for CriteriaVerification and Inspection
IBC
Reference
AISC 360 Table N5.6-1 1705.2O P
O
O
O
O
P
O
O
P P
O
O
1. Fastener assemblies, of suitable condition, placed in all holes and washers (if required) are positioned as required
2. Joint brought to the snug-tight condition prior to the pretensioning operation
3. Fastener component not turned by the wrench prevented from rotating
4. Fasteners are pretensioned in accordance with the RCSC Specification, progressing systematically from the most rigid point toward the free edges
DURING BOLTING - MINIMUM INSPECTION
Inspection Type
QC QA
Reference for CriteriaVerification and Inspection
IBC
Reference
AISC 360 Table N5.6-2 1705.2O
O
O
O
AISC 360 Table N5.6-2 1705.2
AISC 360 Table N5.6-2 1705.2
AISC 360 Table N5.6-2 1705.2
AISC 360 Table N5.6-1 1705.2
AISC 360 Table N5.6-1 1705.2
AISC 360 Table N5.6-1 1705.2
AISC 360 Table N5.6-1 1705.2
AISC 360 Table N5.6-1 1705.2
AISC 360 Table N5.6-1 1705.2
AISC 360 Table N5.4-3 1705.2
AISC 360 Table N5.4-3 1705.2
AISC 360 Table N5.4-3 1705.2
AISC 360 Table N5.4-3 1705.2
AISC 360 Table N5.4-3 1705.2
AISC 360 Table N5.4-3 1705.2
AISC 360 Table N5.4-3 1705.2
AISC 360 Table N5.4-2 1705.2
AISC 360 Table N5.4-2 1705.2
AISC 360 Table N5.4-2 1705.2
AISC 360 Table N5.4-2 1705.2
AISC 360 Table N5.4-2 1705.2
AISC 360 Table N5.4-1 1705.2
AISC 360 Table N5.4-1 1705.2
AISC 360 Table N5.4-1 1705.2
AISC 360 Table N5.4-1 1705.2
AISC 360 Table N5.4-1 1705.2
AISC 360 Table N5.4-1 1705.2
1. Document acceptance or rejection of bolted connections
AFTER BOLTING - MINIMUM INSPECTION
Inspection Type
QC QA
Reference for CriteriaVerification and Inspection
IBC
Reference
AISC 360 Table N5.6-3 1705.2P P
Notes:
1. QC - indicates inspection tasks shall be performed by the fabricator’s or erector’s quality control inspector (QCI), as applicable.
QA - indicates inspection tasks shall be performed by the quality assurance inspector
(QAI)
O - indicates the inspector observe these items on a random basis. Operations need not be delayed pending these inspections.
P - indicates the inspector perform these tasks for each welded joint or member.
2. The fabricator’s QCI shall inspect the fabricated steel to verify compliance with the details shown on the shop drawings, such as proper application of joint details at each connection. The erector’s QCI shall inspect the erected steel frame to verify compliance with the details shown on the erection drawings, such as braces, stiffeners, member locations and proper application of joint details at each connection.
3. The QAI shall be on the premises for inspection during the placement of anchor rods and other embedments supporting structural steel for compliance with the construction documents.
This is the start of the file's text. The full file is on GovTribe.