About this file

This document appears to be an electrical drawing set related to the expansion and renovation of the Emergency Department B50 at the Tucson VA Medical Center. The drawing set includes electrical panel schedules, load information, and equipment details for the project.

The related federal contract opportunity is Solicitation Number 36c77623r0191, titled "Y1DA--Expand and Renovate Emergency Department B50 Minor Construction - Tucson VAMC (VA-24-00001448)". This solicitation is for the expansion and renovation of the Emergency Department at the Tucson, Arizona VA Medical Center. The solicitation is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin.

View the file

Other files

File Type Posted
50-EP601.pdf PDF
50-M703.pdf PDF
50-A701.pdf PDF
50-A102.pdf PDF
50-M601.pdf PDF
50-EP101.pdf PDF
50-M704.pdf PDF
50-A504.pdf PDF
50-A104.pdf PDF
50-GC102.pdf PDF
50-CU101.pdf PDF
Addendum 1.pdf PDF
50-M505.pdf PDF
50-A502.pdf PDF
50-MG702.pdf PDF
50-AC101.1.pdf PDF
50-MH101.1.pdf PDF
50-EP102.pdf PDF
11 73 00 Ceiling Mounted Patient Lift_Rev.pdf PDF
08 80 00 Glazing_Rev.pdf PDF
50-A401.pdf PDF
50-AC101.4.pdf PDF
50-A303.pdf PDF
50-GC101.pdf PDF
50-MH104.pdf PDF
50-M602.pdf PDF
50-M702.pdf PDF
01 00 00 Gen Reqs_Rev.pdf PDF
50-MG100.pdf PDF
Technical Questions Spreadsheet - Tucson - Final.pdf PDF
50-A602.pdf PDF
50-M503.pdf PDF
50-CD101.pdf PDF
50-S450.pdf PDF
50-MG701.pdf PDF
50-S310.pdf PDF
50-M701.pdf PDF
36C77623R0191 0003.pdf PDF
36C77623R0191 0002.pdf PDF
36C77623R0191 0001.pdf PDF
Site Visit Sign in Sheet Pg 1 and 2 - Tucson.pdf PDF
Attachment 8 - Architectural Drawings 2 of 2.pdf PDF
Attachment 14 - Mechanical Drawings.pdf PDF
Attachment 6 - Structural Drawings.pdf PDF
36C77623R0191 - 02-22-24.pdf PDF
Attachment 2 - Specifications - 2 of 3.pdf PDF
Attachment 5 - Civil Drawings.pdf PDF
Attachment 20 - Site Visit Instructions.pdf PDF
Attachment 17 - PTube Drawings.pdf PDF
Attachment 7 - Architectural Drawings 1 of 2.pdf PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

o n e e ig h th i n c h o n e fo o t th re e i n c h e s o n e fo o t o n e a n d o n e h a lf i n c h e s o n e fo o t o n e i n c h o n e fo o t th r e e q u a rt e rs i n c h o n e fo o t o n e h a lf i n c h o n e fo o t th re e e ig h th s i n c h o n e fo o t o n e q u a r te r i n c h o n e fo o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Drawing Title Project Title

VA FORM 08-6231

Office of Facilities Management

U.S. Department of Veterans Affairs

STAMP

Date

Location

Building Number Checked Drawn Drawing Number

Project Number

BID SET

Approved: Director

Approved: Associate Director

Approved: Assistant Director

Approved: Assoc. Director for Patient Care Service/Nurse Executive

Approved: Deputy Assoc. Director of Patient Care Services

Approved: Chief of Staff

Approved: Deputy Chief of Staff

Approved: Chief of Engineering

Approved:

Approved:

ARCHITECT/ENGINEER/CONSULTANTS:

Bancroft Project No.

SAVAHCS, TUCSON, AZ 85723

3300 Dundee Road

Northbrook, IL 60062

T: 847.952.9362

04/30/2024ELECTRICAL - EMERGENCY

PANEL SCHEDULES

EXPAND AND RENOVATE

EMERGENCY DEPARTMENT B50

50 WG BX

50-EP602

678-331

19-103

8-

E X

P A

N D

A N

D R

E N

O V

A T

E E

M E

R G

E N

C Y

D E

P A

R T

M E

N T

B

A

D D

E N

D U

M

R RECEPTACLE LM LARGEST MOTOR H HEATING T TRANSFORMER

L LIGHTING M MOTORS E EQUIPMENT S SUBFED

ISOLATED GROUND BUS 200% NEUTRAL BUS ISC = 14000

GROUND BUS 100% NEUTRAL BUS INTEGRAL TVSS

TOTAL 239.4 239.431 DESIGN

HEATING 235.8 1.00 235.831 DEMAND 239.4 288.0

EQUIPMENT 3.6 1.00 3.6 CONNECTED 269.6 324.3

LARGEST MOTOR 0.0 1.25 0.0 HEATING 0.0 TOTAL KVA AMPS

MOTORS 0.0 1.00 0.0 EQUIP 0.0

RECEPT (REMAINDER) 0.0 0.50 0.0 MOTORS 0.0 PH C 89877

RECEPT (FIRST 10 KW) 0.0 1.00 0.0 RECEPT 0.0 PH B 89877

LIGHTING 0.0 1.00 0.0 LIGHTING 0.0 PH A 89877

(KVA) D.F. (KVA) (KVA)

LOAD DESCRIPTION

CONNECTED DEMAND SUBFED LOADS

CONNECTED VA

29 X 30

27 X 28

25 X 26

23 X 24

21 X 22

19 X 20

17 1200 E X 18

15 1200 E X 16

TR 50-AHU-5 EQ

1200 E

3 50

X 14

11 30200 X 12

9 30200 H X 10

HUMIDIFIER AHU-5

30200 H

3 125

X 8

5 58477 H X 6

3 58477 H X 4

AHU5 MAIN CONNECTION

58477 H

3 250

X 2

NO PH A PH B PH C CODE P TR A B C TR P CODE PH A PH B PH C NO

CKT

LOAD DESCRIPTION

VA LOAD CB BUS CB VA LOAD

LOAD DESCRIPTION

CKT

AHU5-EQ ROOF AHU-5 VESTIBULE SURFACE 50-ATS-AHU5 277/480V. 3PH, 4W 400A 400A

PANEL NAME LOCATION MOUNTING SUPPLIED FROM VOLTAGE BUS MAIN

R RECEPTACLE LM LARGEST MOTOR H HEATING T TRANSFORMER

L LIGHTING M MOTORS E EQUIPMENT S SUBFED

ISOLATED GROUND BUS 200% NEUTRAL BUS ISC = 14KAIC

GROUND BUS 100% NEUTRAL BUS INTEGRAL TVSS

TOTAL 4.7 4.678 DESIGN

HEATING 0.0 1.00 0 DEMAND 4.7 13.0

EQUIPMENT 4.4 1.00 4.368 CONNECTED 4.7 13.0

LARGEST MOTOR 0.0 1.25 0.0 HEATING 0.0 TOTAL KVA AMPS

MOTORS 0.0 1.00 0.0 EQUIP 0.0

RECEPT (REMAINDER) 0.0 0.50 0.0 MOTORS 0.0 PH C 2184

RECEPT (FIRST 10 KW) 0.2 1.00 0.2 RECEPT 0.0 PH B 2304

LIGHTING 0.1 1.00 0.1 LIGHTING 0.0 PH A 190

(KVA) D.F. (KVA) (KVA)

LOAD DESCRIPTION

CONNECTED DEMAND SUBFED LOADS

CONNECTED VA

29 1 20 X 20 1 30

27 1 20 X 20 1 28

25 1 20 X 20 1 26

23 1 20 X 20 1 24

21 1 20 X 20 1 22

19 1 20 X 20 1 20

17 1 20 X 20 1 18

15 1 20 X 20 1 16

13 1 20 X 20 1 14

11 1 20 X 20 1 12

9 1 20 X 20 1 10

7 1 20 X 20 1 8

5 1 20 X E 2184 6

3 LIGHTING AHU-5 120 L 1 20 X

35 2

E 2184

SPLIT COOLING UNIT

1 DUCT SMOKE DET. TEST PWR 10 R 1 15 X 20 1 R 180 AHU-5 RECEPTACLES 2

NO PH A PH B PH C CODE P TR A B C TR P CODE PH A PH B PH C NO

CKT

LOAD DESCRIPTION

VA LOAD CB BUS CB VA LOAD

LOAD DESCRIPTION

CKT

AHU5-ELEQ AHU-5 ON ROOF SURFACE TR AHU5-1, IN AHU-5 ON ROOF 120/208V. 3PH, 4W 50 LUGS

PANEL NAME LOCATION MOUNTING SUPPLIED FROM VOLTAGE BUS MAIN

AHU5-EQ AHU5-ELEQ

Revisions: Date:

BID SET 05/01/2023

ADDENDUM 1 04/30/2024

File details come from the government source that posted it. Updated .