This document appears to be an Architectural - Reflected Ceiling Plan for the expansion and renovation of the Emergency Department B50 at the Tucson VA Medical Center. The plan includes details on ceiling grid layout, lighting fixtures, and specialized equipment such as patient lift systems. The corresponding federal contract opportunity is Solicitation Number 36c77623r0191, which is for the overall Expand And Renovate Emergency Department project at the Tucson VAMC. The solicitation seeks proposals for minor construction work to expand and renovate the emergency department. Key details such as response dates, pricing terms, and set asides are not provided in this architectural plan document. The document is focused on providing technical specifications for the ceiling and lighting elements of the project.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
EE
DD
CC
BB
50-A301
50-A303
SOILED UTILITY
CT
CT CONTROL
PROCEDURE
PROCEDURE
MECHANICAL (E)
ELECTRICAL (E)
BIOMED COMM
CLOSET (E)
113B
EMS SUPPORT
EXAM/ TREATMENT
(ISOLATION)
ANTEROOM
COLLABORATION
NURSE STATION-
SOUTH
DECONTAMINATION
TOILET (STAFF)
TOILET (ISOLATION
PATIENT)
1036A
CLEAN LINEN
ELECTRICAL
CORRIDOR
C2
NOURISHMENT
AMBULANCE
VESTIBULE
1V2
STORAGE- OXYGEN
-A
C .3
9'-0"
9'-0"
10'-2"
9'-0"
9'-0"
9'-0" 9'-0"
8'-0" 8'-0"
9'-0"
8'-0"
9'-0" 9'-0"
8'-0"
9'-0"
9'-0" 9'-0"
50-A304
CORRIDOR
C3
CORRIDOR
C4
CORRIDOR
C5
CORRIDOR
C6
CORRIDOR
C4
50-A304
9'-0"
3/ 4"
5'
- 4
/4
2 2
9'-0"
10'-0"
10'-0"
8'-0"
A1165
ONE HOUR FIRE BARRIER
TWO HOUR FIRE BARRIER
CONTRACTOR IS REQUIRED TO MAINTAIN ALL RATED PARTITIONS.
N o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
Drawing Title Project Title
VA FORM 08-6231
Office of Facilities Management
U.S. Department of Veterans Affairs
STAMP
Date
Location
Building Number Checked Drawn Drawing Number
Project Number
BID SET
Approved: Director
Approved: Associate Director
Approved: Assistant Director
Approved: Assoc. Director for Patient Care Service/Nurse Executive
Approved: Deputy Assoc. Director of Patient Care Services
Approved: Chief of Staff
Approved: Deputy Chief of Staff
Approved: Chief of Engineering
Approved:
Approved:
ARCHITECT/ENGINEER/CONSULTANTS:
Bancroft Project No.
SAVAHCS, TUCSON, AZ 85723
3300 Dundee Road
Northbrook, IL 60062
T: 847.952.9362
KEY PLAN
04/30/2024ARCHITECTURAL - REFLECTED
CEILING PLAN, FIRST FLOOR,
AREA 4
EXPAND AND RENOVATE
EMERGENCY DEPARTMENT B50
50 CZ DTB
50-AC101.4
678-331
19-103
8-
E X
P A
N D
A N
D R
E N
O V
A T
E E
M E
R G
E N
C Y
D E
P A
R T
M E
N T
B
A
D D
E N
D U
M
N 1/4" = 1'-0"
REFLECTED CEILING PLAN, FIRST FLOOR
GENERAL RCP NOTES
1. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION,
PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR FULL SCOPE OF WORK.
2. CENTER ALL CEILING GRIDS IN EACH ROOM UNLESS NOTED OTHERWISE.
3. CENTER ALL FIXTURES WITHIN CEILING TILE UNLESS NOTED OTHERWISE.
4. CONTRACTOR TO VERIFY ABOVE CEILING IN AREAS WHERE CEILING TILE WILL BE RAISED
AND NOTIFY ARCHITECT OF ANY CONFLICTS BEFORE CONSTRUCTION.
PROVIDE AND INSTALL NEW 2'X2' CEILING GRID TILE SYSTEM THROUGHOUT
SCOPE OF WORK (UNO). SEE FINISH SCHEDULE FOR MORE INFORMATION.
PROVIDE AND INSTALL NEW 2'X4' LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS
FOR MORE INFORMATION.
PROVIDE AND INSTALL NEW 2'X2' LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS
FOR MORE INFORMATION.
LINEAR COVE LIGHTING
PROVIDE AND INSTALL NEW GYPSUM BOARD CEILING AT ROOMS INDICATED.
PAINT CEILING PER FINISH SCHEDULE.
RECESSED CAN LIGHT
NOT INCLUDED IN AREA OF WORK
PROVIDE AND INSTALL NEW 1X4 LIGHT FIXTURES. SEE ELECTRICAL DRAWINGS
FOR MORE INFORMATION.
REFLECTED CEILING PLAN LEGEND
KEYNOTES
1 CEILING MOUNTED CURTAIN TRACK.
2 CEILING MOUNTED PATIENT LIFT SYSTEM. LIFT SYSTEM IN IMAGING
ROOMS TO BE COORDINATED WITH FINAL EQUIPMENT SELECTIONS.
3 BARIATRIC CEILING MOUNTED PATIENT LIFT SYSTEM INCLUDING
TRANSITION INTO TOILET ROOM.
0 2' 4' 8'
RATED WALL LEGEND
Revisions: Date:
BID SET 05/01/2023
ADDENDUM 1 04/30/2024
-RFI #24
| Sheets |
| 50-AC101.1 - ARCHITECTURAL - REFLECTED CEILING PLAN, FIRST FLOOR, AREA 1 |
| 50-AC101.4 - ARCHITECTURAL - REFLECTED CEILING PLAN, FIRST FLOOR, AREA 4 |
File details come from the government source that posted it. Updated .