This document appears to be a set of technical drawings and specifications for typical caisson details, which are likely related to a federal contract opportunity.

The drawings provide details on the construction of various types of caissons, including socketed caissons in uncased shafts, square caisson caps, and caisson schedules specifying dimensions, reinforcement, and concrete strength. The document appears to be an addendum or revision to drawings associated with Solicitation Number 36c77623r0191 for the "Expand and Renovate Emergency Department B50 Minor Construction" project at the Tucson VAMC. The solicitation is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The document does not appear to contain any specific pricing terms, set asides, or incumbent information, but rather focuses on the technical requirements for the caisson construction.

View the file

Other files

File Type Posted
50-EP601.pdf PDF
50-M703.pdf PDF
50-A701.pdf PDF
50-A102.pdf PDF
50-M601.pdf PDF
50-EP101.pdf PDF
50-M704.pdf PDF
50-A504.pdf PDF
50-A104.pdf PDF
50-GC102.pdf PDF
50-CU101.pdf PDF
Addendum 1.pdf PDF
50-M505.pdf PDF
50-A502.pdf PDF
50-MG702.pdf PDF
50-AC101.1.pdf PDF
50-MH101.1.pdf PDF
50-EP102.pdf PDF
11 73 00 Ceiling Mounted Patient Lift_Rev.pdf PDF
08 80 00 Glazing_Rev.pdf PDF
50-A401.pdf PDF
50-AC101.4.pdf PDF
50-A303.pdf PDF
50-GC101.pdf PDF
50-MH104.pdf PDF
50-M602.pdf PDF
50-M702.pdf PDF
50-EP602.pdf PDF
01 00 00 Gen Reqs_Rev.pdf PDF
50-MG100.pdf PDF
Technical Questions Spreadsheet - Tucson - Final.pdf PDF
50-A602.pdf PDF
50-M503.pdf PDF
50-CD101.pdf PDF
50-S450.pdf PDF
50-MG701.pdf PDF
50-M701.pdf PDF
36C77623R0191 0003.pdf PDF
36C77623R0191 0002.pdf PDF
36C77623R0191 0001.pdf PDF
Site Visit Sign in Sheet Pg 1 and 2 - Tucson.pdf PDF
Attachment 8 - Architectural Drawings 2 of 2.pdf PDF
Attachment 14 - Mechanical Drawings.pdf PDF
Attachment 6 - Structural Drawings.pdf PDF
36C77623R0191 - 02-22-24.pdf PDF
Attachment 2 - Specifications - 2 of 3.pdf PDF
Attachment 5 - Civil Drawings.pdf PDF
Attachment 20 - Site Visit Instructions.pdf PDF
Attachment 17 - PTube Drawings.pdf PDF
Attachment 7 - Architectural Drawings 1 of 2.pdf PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3" CLR

PROVIDE LTS LAP IF

SPLICE IS REQUIRED

CL

CAISSON

VERTICAL REINFORCEMENT

SEE SCHEDULE

ROUGHENED CLEAN

SURFACE

T/CAISSON

EL SEE PLAN

TIES

SEE SCHEDULE

LT

S

5'

M

IN

LEVEL OF EXISTING FILLS

AS DETERMINED BY THE

GEOTECHNICAL ENGINEER OF RECORD

C A

IS

S

O N

C A

P O

R G

R A

D E

B E

A M

C

LR3"

T

IE

S

S E

E S

C H

E D

U

LE

CENTRALIZERS NOT SHOWN

PROVIDE WHERE REQUIRED

BY SPECIFICATIONS

FORM TOP AS REQUIRED

TO PREVENT

MUSHROOMING

SEE SCHEDULE

SHAFT DIAMETER

NOTES:

1. MINIMUM CAISSON LENGTH IS 15'-0" OR 5'-0" BELOW LEVEL OF EXISTING FILL, WHICH EVER IS

GREATER, PER GEOTECHNICAL ENGINEER OF RECORD

(S E

E N

O T

E

C A

IS

S

O N

L E

N G

T H

BEARING STRATUM

FOR NET ALLOWABLE

BEARING PRESSURE

SEE GENERAL NOTES

(TO BE VERIFIED BY

THE GEOTECHNICAL

TESTING AGENCY)

MARK

SIZE

f'c = SEE GENERAL NOTES

REMARKS

CAISSON

LENGTH

SHAFT

DIAMETER

REINFORCEMENT

TIES

VERTICAL

BARS

SOCKETED CAISSON SCHEDULE

4'-0" 20'-0" 15-#10 #4@10"C2

C3 2'-0" 20'-0" 6-#8 #4@1'-4"

5'-0" 20'-0" 23-#10 #4@8"C1

C4 2'-6" 20'-0" 12-#8 #4@1'-0"

C5 3'-0" 20'-0" 12-#9 #4@1'-0"

NOTES:

1. MINIMUM CAISSON LENGTH IS 15'-0" OR 5'-0" BELOW LEVEL OF EXISTING FILL, WHICH EVER IS

GREATER, PER GEOTECHNICAL ENGINEER OF RECORD

HORIZONTAL TIES

SEE SCHEDULE

CL

CAISSON

CL

CAISSON

CL

CAISSON

PLAN

SEE CAISSON SCHEDULE

SHAFT DIAMETER

S E

E S

C H

E D

U

LE

H

T/CAISSON CAP

EL SEE PLAN

T/CAISSON

EL SEE PLAN

SEE SCHEDULE

W / L

8-#6 W/ STD

HOOK ,TYP

CAISSON

BELOW

HORIZ. TIES,

SEE SCHEDULE

S E

E S

C H

E D

U

LE

W

CAISSON

SHAFT

'-0

LT

S

ROUGHENED CLEAN

SURFACE

REINFORCEMENT

SEE CAISSON SCHEDULE

SOG

REINF NOT

SHOWN

C A

P T

I E

3" T

O F

IR

S

T

T Y

P

3" C

LR

EXTEND CAP VERT

REINF INTO SOG

LTS LAP WITHIN CAP IS

PERMITTED2' - 0"

SEE SCHEDULE

L

NOTES:

1. CASE "A" APPLIES WHERE LEAST PLAN DIMENSION OF CAISSON CAP IS SMALLER THAN

DIAMETER OF CAISSON. WHERE CAP IS LARGER THAN CAISSON, SEE CASE "B"

CC1 3'-0" 3'-0" SQUARE CAP

MARK

SIZE

f'c = SEE GENERAL

NOTES

REMARKS

HW

REINFORCEMENT

CAISSON CAP SCHEDULE

#5 @8"

HORIZONTAL

TIES

CC3 2'-6" 3'-0" SQUARE CAP#4 @8"

CC4 3'-0" 3'-0" #4 @8" SEE PLAN FOR ORIENTATION

3'-0"

L

2'-6"

6'-6"

HORIZONTAL TIES

SEE SCHEDULE

ROUGHENED CLEAN

SURFACE

REINFORCEMENT

SEE CAISSON SCHEDULE

EXTEND CAISSON VERTICAL

REINFORCEMENT TO TOP OF

SQUARE CAP

CAISSON SHAFT

CL

CAISSON

CL

CAISSON

CL

CAISSON

PLAN

CAISSON CAP

EL SEE PLAN

T/CAISSON

EL SEE PLAN

TYPICAL

3" MIN

SEE SCHEDULE

W

CAISSON

BELOW

HORIZ. TIES,

SEE SCHEDULE

3" C

LR

NOTES:

1. CASE "B" APPLIES WHERE LEAST PLAN DIMENSION OF CAISSON CAP IS LARGER THAN

DIAMETER OF CAISSON.

2. FOR INFORMATION NOT SHOWN SEE 6/50-S310

8-#6 W/ STD

HOOK ,TYP

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

Drawing Title Project Title

VA FORM 08-6231

Office of Facilities Management

U.S. Department of Veterans Affairs

STAMP

Date

Location

Building Number Checked Drawn Drawing Number

Project Number

REVIEW ONLY - NOT FOR CONSTRUCTION

Approved: Director

Approved: Associate Director

Approved: Assistant Director

Approved: Assoc. Director for Patient Care Service/Nurse Executive

Approved: Deputy Assoc. Director of Patient Care Services

Approved: Chief of Staff

Approved: Deputy Chief of Staff

Approved: Chief of Engineering

Approved:

Approved:

ARCHITECT/ENGINEER/CONSULTANTS:

Bancroft Project No.

SAVAHCS, TUCSON, AZ 85723

3300 Dundee Road

Northbrook, IL 60062

T: 847.952.9362 50

04/30/2024TYPICAL CAISSON DETAILS EXPAND AND RENOVATE

EMERGENCY DEPARTMENT B50

JH HL

50-S310

678-331

8-

E X

P A

N D

A N

D R

E N

O V

A T

E E

M E

R G

E N

C Y

D E

P A

R T

M E

N T

B

A

D D

E N

D U

M

R

F I #

D

NOT TO SCALE

TYPICAL SOCKETED CAISSON IN UNCASED SHAFT

NOT TO SCALE

CAISSON SCHEDULE

NOT TO SCALE

TYPICAL SQUARE CAISSON CAP DETAIL - CASE A

NOT TO SCALE

CAISSON CAP SCHEDULE

Revisions: Date:

BID SET 05/01/2023

ADDENDUM 1 - RFI #38D 04/30/2024

NOT TO SCALE

TYPICAL SQUARE CAISSON CAP DETAIL - CASE B

T/SOG

SEE PLAN

T/SOG

SEE PLAN

Sheets
50-S310 - TYPICAL CAISSON DETAILS

File details come from the government source that posted it. Updated .