Attachment 1 (L6) - AR-MTP-25-206_100percent Nylon Laminate - PTFE_1.1_05Sep2025.pdf

PDF 5 MB Posted

Attached to
All-Range Tactical Clothing (ARTC) Request for Information
Solicitation number
W911QY25RARTC
Issued by

About this file

This document is a Department of Defense Clothing and Textiles specification for a raw material fabric (Fabric# AR-MTP-25-206) for the Army. The specification details a 100% Nylon Laminate with PTFE (polytetrafluoroethylene) for the year 2025, classified as a multi-layer laminated fabric with a Type III laminated fabric defect classification. The fabric is a 5.1 oz/yd² ripstop nylon material in the Army Operational Camouflage Pattern (OCP) print, designed as rolled goods.

The specification includes extensive technical requirements for material properties, including break strength (minimum 100 lbs warp, 130 lbs fill), water repellency, hydrostatic pressure resistance, water vapor transmission rates, and color fastness tests. Critical performance characteristics include resistance to perspiration, crocking, laundering, and exposure to DEET insect repellent. The fabric must meet stringent quality standards, with specific acceptable quality limits for defects such as holes, tears, lamination issues, and color matching. The material is intended for military textile applications and must pass rigorous first article and conformance inspections to ensure it meets the Department of Defense's technical and performance specifications.

View the file

Other files

File Type Posted
Attachment 1 (L6) - AR-MTP-24-143_Lightweight Non-fusible Interlining_1.1_05Sep2025.pdf PDF
Attachment 1 (L4) - AR-MTP-24-136_Cloth_Hard Face Fleece_1.1_05Sep2025.pdf PDF
Attachment 1 (L4) - AR-MTP-25-155_Shadow Box Dobby Ripstop_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-25-196_Cloth_Batting_Polyester 4 oz_1.1_05Sep2025.pdf PDF
Attachment 1 (L1) - AR-MTP-24-204_Cloth_Rib Knit_1.1_05Sep2025.pdf PDF
Attachment 1 (L4) - AR-MTP-24-143_Lightweight Non-fusible Interlining_1.1_05Sep2025.pdf PDF
Attachment 1 (L1) - AR-MTP-23-203_Cloth_Mesh Knit_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-MTP-24-134_Nylon Plain Weave_1.1_05Sep2025.pdf PDF
Attachment 4.xlsx XLSX spreadsheet
Attachment 1 (L6) - AR-MTP-25-200_Adhesive Sheet 2-Layer_1.1_05Sep2025.pdf PDF
Attachment 1 (L6) - AR-MTP-25-201_3 Layer Seam Seal Tape_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-ETP-25-094-Softshell Jacket_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-MTP-24-143_Lightweight Non-fusible Interlining_1.1_05Sep2025.pdf PDF
Attachment 1 (L6) - AR-MTP-25-207_Three-layer Knit Laminate_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-24-162_Nylon Ripstop 40D_1.1_05Sep2025.pdf PDF
Attachment 1 (L1) - AR-ETP-25-106_Mesh Drawers_1.1_05Sep2025.pdf PDF
Attachment 3.pdf PDF
Attachment 1 (L7) - AR-MTP-24-136_Cloth_Hard Face Fleece_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-24-161_Plain Weave Nylon 70D_1.1_05Sep2025.pdf PDF
Attachment 1 (L4) - AR-MTP-24-154_Lightweight Nylon Ripstop_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-24-156_Woven Stretch 4-way_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-25-202_Knit Cuff_1.1_05Sep2025.pdf PDF
Attachment 1 (L4) - AR-ETP-25-102_Insulated Liner Jacket_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-MTP-25-197_330D Nylon 6 oz_1.1_05Sep2025.pdf PDF
Attachment 1 (L6) - AR-MTP-24-154_Lightweight Nylon Ripstop_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-MTP-24-156_Woven Stretch 4-way_1.1_05Sep2025.pdf PDF
Attachment 1 (L6) - AR-ETP-25-100_ARTC Cold Wet Trouser_1.1_05Sep2025.pdf PDF
Attachment 1 (L6) - AR-ETP-25-101_ARTC Cold Wet Jacket_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-ETP-25-103-Softshell Trouser_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-24-163_Heavyweight_Interlining_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-24-135_Mesh_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-ETP-25-095_ARTC Extreme Cold Trouser_1.1_05Sep2025.pdf PDF
Attachment 1 (L4) - AR-MTP-24-142_Cloth_Batting_Polyester 2.4 oz_1.1_05Sep2025.pdf PDF
Attachment 1 (L6) - AR-MTP-25-199_Nylon Spandex Stretch Woven_1.1_05Sep2025.pdf PDF
Attachment 2.xlsx XLSX spreadsheet
Attachment 1 (L5) - AR-MTP-24-135_Mesh_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-MTP-24-157_Twill Weave 4-way Stretch_1.1_05Sep2025.pdf PDF
Attachment 1 (L1) - AR-MTP-24-205_Cloth_Jersey Knit_1.1_05Sep2025.pdf PDF
Attachment 1 (L5) - AR-MTP-24-158_330D Nylon 5.5 oz_1.1_05Sep2025.pdf PDF
Attachment 1 (L6) - AR-MTP-24-158_330D Nylon 5.5 oz_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-MTP-24-160_Plain Weave Outer shell_1.1_05Sep2025.pdf PDF
Attachment 1 (L1) - AR-ETP-24-107_Mesh Undershirt_1.1_05Sep2025.pdf PDF
Attachment 1 (L7) - AR-ETP-25-093_ARTC Parka_1.1_05Sep2025.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Department of Defense Clothing and Textiles

RM # AR-MTP-25-206

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Year 2025

RM Status In Process

Size Range zRM - Rolled Goods |

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

General Statements - Scope Category Description Statements

Classification Material General Statement The fabric(s) shall be of the following types, classes and styles as specified in the contract..

Scope

9/5/2025 Page 1 of 19

Fabric# AR-MTP-25-206

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Style Colors Color Swatch (Ref)L (Ref)A (Ref)B Comments

0001 | Army OCP Print |

General Statements - Colors Category Description Statements

General Statement - Colors Material The fabric(s) shall be in the following color(s) as specified in the contract.

Colors

9/5/2025 Page 2 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

General Statements - Material Construction GS Tab Category Description Detail Statements

Construction General Statement - Construction

Material and Component Material and component construction shall conform to the requirements specified as verified by the quality requirements and inspection methods specified. Following the exact sequence of operations is not required, provided the finished material meets the physical requirements and appearance as those produced by following the sequence of operations.

Construction Workmanship Material General Statement General Statement The finished material shall be uniform, and the occurrence of defects, shall not exceed the established Acceptance Quality Limits (AQL) in the contract and shall not adversely affect the serviceability, appearance, and uniformity of the product.

Material Construction

Yarn Ply

Yarn Details

Fiber Percentage Yarn 1 Yarn 100 Nylon

Total Composition Nylon 100

Fiber Percentage Yarn 2 Yarn

Total Composition B

Fiber/Yarn/Additional Details Laminated Cloth with a 100% Nylon Ripstop face fabric.

Woven Information

Weave Type Ripstop

Warp Count

Knit Information

Knit Type

Gauge

General Information

Fabric Weight 5.1

UOM Oz/yd2|Ounces per square yard

9/5/2025 Page 3 of 19

Additional Construction Details Image Description

Width 0

UOM

Thickness (inches)

Appearance/Hand

Weft Count

Shinkage Length 0

UOM

Shirinkage Width 0

UOM

Wales

Courses

9/5/2025 Page 4 of 19

Style# AR-MTP-25-206

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Style Status

Platform

Environment

End Use

Gender

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

General Statements - Inspection Methods Category Description Detail Statements

Inspection Methods Inspection Conditions General Statement General Statement Unless otherwise specified in the contract inspections shall be performed in accordance with the test conditions specified in applicable test method documents and as specified by the inspection methods.

General Statements - Conformance Category Description Detail Statements

Conformance Inspection Material and Component Acceptance Criteria The lot shall be unacceptable if the number of defects exceeds the Acceptable Quality Limits (AQL) or the failure of any test.

Conformance Inspection Material and Component Sampling Unless otherwise specified in subsidiary specifications, referenced documents, or procurement documents material and component sampling shall be (2) sample units for lots 800 yards of less, (3) sample units for lots 801 yards to 22,000 yards and (4) sample units for lots over 22,000 yards. For material testing, the sample unit shall be 5 continuous yards full width of the finished cloth for all physical and chemical tests.

Conformance Inspection Requirement General Statement Samples shall be subjected to Conformance inspections for compliance with design, configuration, workmanship, dimensional and testing requirements. Conformance inspection shall consist of the inspection methods, examinations and tests specified.

Quality

General Statements - First Article Category Description Detail Statements

First Article Inspection - Quality

Acceptance Criteria General Statement The presence of defects exceeding AQLs specified in the contract or failure of any testing (end item, material or component) shall be cause for rejection of the first article.

First Article Inspection - Quality

Requirement General Statement Samples shall be subjected to First Article inspection for compliance with design, configuration, workmanship, dimensional and testing requirements. First article inspection shall consist of the inspection methods, examinations and tests specified.

First Article Inspection - Quality

Sampling General Statement The sample size shall be as specified in the contract. The sample unit shall be one finished end item and the lot size shall be expressed in units of end items.

Additional Quality General Statements Category Description Detail Statement

9/5/2025 Page 5 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Material Properties

Characteristic Characteristic Additional Detail UOM Min/Max Requirements Source Test method Test Method Options

Break Strength warp lbs|Pounds Minimum 100 ASTM International ASTM D5034|Standard Test Method for

Breaking Strength and Elongation of Textile Fabrics (Grab Test)|3363|

G-E or G-T

Break Strength fill lbs|Pounds Minimum 130 ASTM International ASTM D5034|Standard Test Method for

Breaking Strength and Elongation of Textile Fabrics (Grab Test)|3363|

G-E or G-T

3 Spray rating Initial Minimum 100, 100, 90 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM22|Water Repellency:

Spray|3363|

4 Spray rating After Laundering, 3 cycles Minimum 100, 90, 90 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM22|Water Repellency:

Spray|3363|

AATCC 135 (1), III, (Ai) First article testing

Hydrostatic Pressure Initial PSI|Per square inch

Minimum 110 ASTM International ASTM D751 |Sttandard Test Method for Coated Fabrics|3363|

Initial. ASTM D751, Hydrostatic Resistance, Procedure A (Pressure Application by Mullen Type Hydrostatic Tester), Procedure 1 with water pressure applied to the face side of the test specimen

Hydrostatic Pressure Low or High after Strength of Coating

PSI|Per square inch

Minimum 110 ASTM International ASTM D751 |Sttandard Test Method for Coated Fabrics|3363|

ASTM D751, except that the testing machine clamp separation rate shall be 5 millimeters per second (12-inches per minute) and a load of twenty (20) pounds shall be applied. Hydrostatic resistance shall be determined in accordance with ASTM D751, Hydrostatic Resistance, Procedure A (Pressure Application by Mullen Type Hydrostatic Tester), Procedure 1 with water pressure applied to the face side of the test specimen.

Material Properties and Testing

General Statements - Material Component and Physical Requirements Gs Tab Category Description Detail Statements

Material Properties and Testing

Material Standard Samples General Statement The finished material shall match the standard sample for shade and appearance and shall be equal to or better than the standard sample with respect to all characteristics for which the standard sample is referenced.

Material Properties and Testing

Physical Requirements - Material Properties and Testing

Material General Statement General Statement The finished material shall conforms to the requirements listed when tested as specified.

9/5/2025 Page 6 of 19

Material Properties

Characteristic Characteristic Additional Detail UOM Min/Max Requirements Source Test method Test Method Options

Hydrostatic Pressure Low or High after High Humidity

PSI|Per square inch

Minimum 110 ASTM International ASTM D751 |Sttandard Test Method for Coated Fabrics|3363|

Three (3), 4-inch by 4-inch specimens shall be laid flat, face side up, on a supporting plate and the assembly placed in a desiccator containing water in the lower portion. The water level shall be approximately 1-inch below the specimens. The lid of the desiccator shall be put in place and the desiccator placed in a circulating air oven having a temperature of 125°F (± 2)°F for a period of seven (7) days. At the end of the aging period, each specimen shall be removed from the desiccator and then immediately examined for colorfastness and tested for hydrostatic resistance. The specimens shall be tested for hydrostatic resistance in accordance with ASTM D751, Hydrostatic Resistance, Procedure A (Mullen Type), Procedure 1 with water pressure applied to the face side of the test specimen.

Hydrostatic Pressure After DEET - Initial PSI|Per square inch

Minimum 110 ASTM International ASTM D751 |Sttandard Test Method for Coated Fabrics|3363|

Five (5) specimen shall be laid flat, face side up on a 4-inch by 4-inch by 1/4-inch, glass plate. Three (3) drops of diethyltoluamide containing 75 percent diethyltoluamide and 25 percent ethanol shall be applied to the center of each specimen. A glass plate of the same dimensions shall be placed on the specimen (or specimen assembly) and a pressure of 0.25 pounds per square inch of glass plate contact area shall be applied to the assembly. After 16 hours, the specimens shall be removed from between the glass plates and tested immediately for hydrostatic resistance in accordance with ASTM D751, Procedure A (Mullen type), Procedure 1, or Procedure B, Procedure 2.

Hydrostatic Pressure After DEET - After Laundry PSI|Per square inch

Minimum 110 ASTM International ASTM D751 |Sttandard Test Method for Coated Fabrics|3363|

Five (5) specimen shall be laid flat, face side up on a 4-inch by 4-inch by 1/4-inch, glass plate. Three (3) drops of diethyltoluamide containing 75 percent diethyltoluamide and 25 percent ethanol shall be applied to the center of each specimen. A glass plate of the same dimensions shall be placed on the specimen (or specimen assembly) and a pressure of 0.25 pounds per square inch of glass plate contact area shall be applied to the assembly. After 16 hours, the specimens shall be removed from between the glass plates and tested immediately for hydrostatic resistance in accordance with ASTM D751, Procedure A (Mullen type), Procedure 1, or Procedure B, Procedure 2.

10 Water Vapor Transmission Rate (WVTR) g/m^2/24h - Procedure B Minimum 650 ASTM International ASTM E96|Water Vapor Transmission Rate(WVTR) Inverted or Upright|3363|

11 Water Vapor Transmission Rate (WVTR) g/m^2/24h Procedure BW Minimum 6000 ASTM International ASTM E96|Water Vapor Transmission Rate(WVTR) Inverted or Upright|3363|

9/5/2025 Page 7 of 19

Material Properties

Additional Detail UOM Min/Max Requirements Source Test method Test Method Options

12 Water Vapor Transmission Rate (WVTR) after synthetic perspiration

- g/m^2/24h Procedure B

Minimum 650 ASTM International ASTM E96|Water Vapor Transmission Rate(WVTR) Inverted or Upright|3363|

13 Water Vapor Transmission Rate (WVTR) after synthetic perspiration

- g/m^2/24h Procedure BW

Minimum 4500 ASTM International ASTM E96|Water Vapor Transmission Rate(WVTR) Inverted or Upright|3363|

Weight Oz/yd2|Ounces per square yard Maximum 5.1 ASTM International ASTM D3776 / D3776M|Standard Test

Methods for Mass Per Unit Area (Weight) of Fabric|3363|

Method C

15 Dimensional Stability warp %|Percentage Maximum 4 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM135|Dimensional Changes of Fabrics after Home Laundering|3363|

(1), III, (Ai)

16 Dimensional Stability fill %|Percentage Minimum 2 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM135|Dimensional Changes of Fabrics after Home Laundering|3363|

(1), III, (Ai)

Blocking Maximum 1 ASTM International ASTM D751 |Sttandard Test Method for Coated Fabrics|3363|

Blocking. ASTM D751, Blocking Resistance at Elevated Temperatures, except that the tests shall be performed at a temperature of 180º (± 2)ºF for 30 minutes. Only one (1) specimen shall be tested. Evaluate the resistance of the specimen to blocking by the scale given below:

1 -- No Blocking. Cloth surfaces are free and separate without any evidence of cohesion or adhesion.

2 -- Trace Blocking. Cloth surfaces show slight cohesion or adhesion.

3 -- Slight Blocking. Cloth surfaces must be lightly peeled to separate.

4 -- Blocking. Cloth surfaces separate with difficulty or coating is removed during separation.

Toxicity The finished cloth shall not present a health hazard and shall show compatibility with prolonged, direct skin contact, as specified in 40 CFR §798.2250, Dermal Toxicity, and 40 CFR §798.4100, Dermal Sensitization. Chemicals recognized by the Environmental Protection Agency as human carcinogens shall not be used.

Department of Defense - Internal ITP6|Toxicity|3363| First article testing

Spectral Reflectance Shall meet the requirements for the Operational Camouflage Pattern and Near IR requirement.

Department of Defense - Internal ITP4|Spectral Reflectance |3363|

Additional Material Properties and Testing

Characteristic Characteristic Additional Detail

Unit Of Measure Min/Max Requirements Source Test method Test Method Options

9/5/2025 Page 8 of 19

Additional Material Properties and Testing

Additional Detail

Unit Of Measure Min/Max Requirements Source Test method Test Method Options

1 Water Permeability Initial No leakage ASTM International ASTM D 751 Standard Test Method for Coated Fabrics

ASTM D751, Hydrostatic Resistance, Procedure B, Procedure 2 with a fixed hydrostatic head of 50 centimeters applied to the face side of the test specimen for ten (10) minutes. Five

(5) specimens shall be tested. The report shall only include measurement for the appearance of water droplets.

For basic shell material, leakage is defined as the appearance of one (1) or more droplets of water within the 4-1/2 inch diameter test area.

2 Water Permeability After Synthetic Perspiration

– Initial No leakage ASTM International ASTM D 751 Standard Test Method for

Coated Fabrics

Synthetic perspiration test. The specimen, 8-inches, shall be cut and exposed to synthetic perspiration as follows: The synthetic perspiration solution shall be made by combining

3.0 grams sodium chloride, 1.0 gram trypticase soy broth powder, 1.0 gram normal propyl propionate, 0.5 gram of liquid lecithin and 500 milliliters of distilled water. Cover the solution and stir while heating to 50ºC until all ingredients are dissolved. Then, cool the solution to 35ºC, remove cover and dispense it immediately with a pipette or other suitable measuring device.

Dispense 2 milliliters of perspiration solution at 35ºC onto the center of an 8-inch by 1/4-inch glass plate. Place the specimen on the glass plate with the back side contacting the glass.

Dispense an additional 2 milliliters of synthetic perspiration solution onto the center of the specimen. Place a second 8-inch by 8-inch by 1/4-inch glass plate on top of the specimen and then place a 4-pound weight on top of and in the center of the assembly. After 16 hours, remove the specimen (do not rinse) and air dry the specimen before testing.

3 Water Permeability After Synthetic Perspiration

– After Wash No leakage ASTM International ASTM D 751 Standard Test Method for

Coated Fabrics

4 Water Permeability After Physical Surface Appearance No leakage ASTM International ASTM D 751 Standard Test Method for

Coated Fabrics

Physical surface appearance. Conduct 20 laundering and drying cycles in accordance with the laundering procedure listed below. Each sample, 48-inches in length by full width, shall be cut in half across the width of the cloth. One half (1/2) of the sample (24-inches in length) shall be laundered and the remaining half retained as the unlaundered portion for the final evaluation, as necessary.

After each drying cycle, examine both sides of the cloth for changes in physical surface appearance when compared to the unlaundered sample.

9/5/2025 Page 9 of 19

Additional Material Properties and Testing

Additional Detail

Unit Of Measure Min/Max Requirements Source Test method Test Method Options

5 Water Permeability After flex (70F) No leakage ASTM International ASTM D 751 Standard Test Method for Coated Fabrics

Water permeability after flex at 70ºF.

One (1) specimen, 8-inches by 12-inches, shall be cut from the sample unit with the 8-inch dimension in the indicated direction (warp or filling, as applicable). The specimen shall be conditioned and flexed as specified in ASTM F392/F392M, except that the specimen shall not be aged, the short edges shall not be heat sealed or otherwise joined, and the specimen shall be flexed for 1500 cycles. Two (2), 6-inch by 8-inch specimens shall be cut from the 8-inch by 12-inch flexed specimen and tested for water permeability in accordance with ASTM D751, Hydrostatic Resistance, Procedure B, Procedure 2 with a fixed hydrostatic head of 50 centimeters applied to the face side of the test specimen for ten (10) minutes. For basic shell material, leakage is defined as the appearance of one (1) or more droplets of water within the 4-1/2 inch diameter test area.

Laundering Procedure for Physical surface appearance

Laundering procedure. Place 2.0 (± 0.2) pounds of the cloth and, if needed, ballast in an automatic washing machine set on permanent press cycle, high water level and warm 100ºF (+10ºF, -0ºF) wash temperature. Place

0.5 ounce (14 grams) of 1993 AATCC Standard Reference Detergent (non-phosphate) without optical brighteners into the washer. The duration of each laundering cycle shall be 30 (± 5) minutes. After laundering, place sample and ballast in an automatic tumble dryer set on permanent press cycle, 150ºF-160°F, and dry for approximately 15 minutes.

The laundering equipment, washer and dryer, shall be in accordance with

AATCC-135.

7 Water Permeability After diethyltolumide No leakage ASTM International ASTM D 751 Standard Test Method for Coated Fabrics

8 Tear Strength warp kg|Kilograms Minimum 2.8 ASTM International ASTM D2582 Standard Test Method for Puncture-Propagation Tear Resistance of Plastic Film and Thin Sheeting

9 Tear Strength fill kg|Kilograms Minimum 3.2 ASTM International ASTM D2582 Standard Test Method for Puncture-Propagation Tear Resistance of Plastic Film and Thin Sheeting

9/5/2025 Page 10 of 19

Material Properties Color

Color Characteristic Characteristic and Additional Details UOM Min/Max Requirements Source Test method Test Method Options

Colorfastness - Laundering

- Color Change

3 cycles Minimum 3 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM61|Colorfastness to Laundering: Accelerated|3363|

AATCC-61, Test 1A (3 cycles) except that 1993 AATCC Standard Reference Detergent (non-phosphate) without optical brighteners shall be used.

Colorfastness - Laundering

- Staining

3 cycles Minimum 3 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM61|Colorfastness to Laundering: Accelerated|3363|

AATCC-61, Test 1A (3 cycles) except that 1993 AATCC Standard Reference Detergent (non-phosphate) without optical brighteners shall be used.

Colorfastness - Light Dark Green 528, Brown 529, Bark Brown 561

Minimum 3 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM16.2|Colorfastness to Light:

Carbon-Arc|3363|

Light. AATCC-16.2 or 16.3 (after 40 AATCC fading units/ after 170 kilojoules/m2nm at 420nm). Evaluated according to AATCC EP 1 Evaluation Procedure for Gray Scale Color Change.

Colorfastness - Light Dark Cream 559, Tan 525, Light Sage 560, Olive 527

Minimum 3 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM16.2|Colorfastness to Light:

Carbon-Arc|3363|

Light. AATCC-16.2 or 16.3 (after 40 AATCC fading units/ after 170 kilojoules/m2nm at 420nm).

First article testing

Additional Material Properties and Testing

Characteristic Characteristic Additional Detail

Unit Of Measure Min/Max Requirements Source Test method Test Method Options

10 Diethyltoluamide (DEET Insect Repellent) reagent.

Diethyltoluamide (DEET Insect Repellent) reagent.

The insect repellent reagent shall be a solution of 75 percent by weight (min) of diethyltoluamide and the remainder denatured alcohol. The diethyltoluamide component of the solution shall be a technical grade and contain N, N-diethyl-metatoluamide of not less than 95 percent purity and the remainder shall consist of entirely or mixture of ortho or para isomers of N, N-diethyltoluamide. The denatured alcohol component of the solution shall be ethanol, U.S.P.

94.9 percent by volume and denatured in accordance with The Code of Federal Regulations 27 CFR 21, Formula 40. The insect repellent must be registered with the U.S.

Environment Protection Agency in accordance with the Federal Insecticide, Fungicide and Rodenticide

(For guidance purposes only, DEET insect repellent conforming to Type II, Concentration A of O-I-503 has been used successfully as a reagent in testing.)

11 Pattern Execution The pattern of the cloth shall be matched to the pattern: drawing 2-1-2592.

9/5/2025 Page 11 of 19

Material Properties Color

Color Characteristic Characteristic and Additional Details UOM Min/Max Requirements Source Test method Test Method Options

Colorfastness - Perspiration - Staining - Acid and Alkaline

All Colors Minimum 3 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM15|Colorfastness to Perspiration|3363|

Rated using AATCC Gray Scale for Staining

Colorfastness - Perspiration - Color Change - Acid and Alkaline

All Colors Minimum 3 American Association of Textile Chemist and Colorists (AATCC)

AATCC TM15|Colorfastness to Perspiration|3363|

Rated using AATCC Gray Scale for Color Change

Colorfastness - Crocking wet - All Colors Minimum 3.5 American Association of Textile

Chemist and Colorists (AATCC) AATCC TM8|Colorfastness to Crocking:

Crockmeter|3363|

Rated using the AATCC EP8, Evaluation Procedure for AATCC 9-Step Chromatic Transference Scale.

Colorfastness - Crocking dry - All Colors Minimum 3.5 American Association of Textile

Chemist and Colorists (AATCC) AATCC TM8|Colorfastness to Crocking:

Crockmeter|3363|

Rated using the AATCC EP8, Evaluation Procedure for AATCC 9-Step Chromatic Transference Scale.

Visual Shade Matching Good Match to Standard Sample

American Association of Textile Chemist and Colorists (AATCC)

The color and appearance of the cloth shall match the standard sample when viewed using the AATCC Evaluation Procedure 9, Option A or C, with sources simulating artificial daylight D65 illuminant with a color temperature of 6500 (± 200)K illumination of 100 (± 20) foot candles, and shall be a good match to the standard sample under incandescent lamplight at 2856 (± 200)K

9/5/2025 Page 12 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Internal Test Procedures

Material Internal Test Procedures Source Test Method Test method options Test method description

Department of Defense - Internal

ITP6|Toxicity|3363| First article testing If dermal toxicity testing is required, it will be conducted in accordance with Title 40 of the Code of Federal Regulations, current editions and applicable sections, which are consistent with OECD tests: Skin Sensitization 406 and Dermal Irritation 404 (https://www.oecd-ilibrary.org/environment/oecd-guidelines-for-the-testing-of -chemicals-section-4-health-effects_20745788?page=1). Dermal sensitization:

https://www.law.cornell.edu/cfr/text/40/798.4100 Dermal toxicity:https://www.law.cornell.edu/cfr/text/40/798.2250

Department of Defense - Internal

ITP4|Spectral Reflectance |3363| Spectral reflectance test. Spectral reflectance data shall be obtained from 600 to 860 nanometers (nm) (NOTE: 700 to 860 nanometers (nm) for Desert Camouflage) at 20 nm intervals on a spectrophotometer relative to the polytetrafluoroethylene (PTFE) family of compounds, the preferred white standard. Other white reference materials may be used provided they are calibrated to absolute white or vitrolite tiles. The spectral band width shall be less than 20 nm at 860 nm. Reflectance measurements shall be made by either the monochromatic or polychromatic mode of operation. When the polychromatic mode of operation is used, the spectrophotometer shall operate with the specimen diffusely illuminated with the full emission of a continuous source that simulates either CIE Source A or CIE Source D65. Measurements shall be taken on a minimum of two (2) different areas and the data averaged. The measured areas should be at least 6-inches away from the selvage. (NOTE: this will not apply to webbings, etc.) The specimen shall be measured as a single layer backed with XXX layers of the same fabric and shade. (NOTE: XXX layers of fabric will vary according to material) The specimen shall be viewed at an angle no greater than 10° from normal, with the specular component included. Measurements shall be taken on a minimum of two (2) different areas. Specimens shall be oriented in different directions during testing. When possible, the specimens tested shall not contain the same Warp or filling yarns/ Wales or courses when presented to the sample port. Camouflage materials should be measured with the appropriate aperture size to ensure that only one (1) color is measured at a time. Always try to use the largest aperture possible. Photometric accuracy of the spectrophotometer shall be within one (1) percent and wavelength accuracy within two (2) nm. Any color having spectral reflectance values falling outside the limits at four (4) or more of the wavelengths specified shall be considered a test failure.

9/5/2025 Page 13 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Defects Material Fabric type Defect Type Defect Description Details Major Minor

1 Multi Layer Laminated Type III - Laminated fabrics Any hole, cut, pinhole, tear, abrasion mark. ¨ ¨

2 Multi Layer Laminated Type III - Laminated fabrics Edge ravels when pulled outward. ¨ ¨

3 Multi Layer Laminated Type III - Laminated fabrics Broken or missing yarn. ¨ ¨

4 Multi Layer Laminated Type III - Laminated fabrics Any spot, stain or streak more than 1-inch in combined directions. ¨ ¨

5 Multi Layer Laminated Type III - Laminated fabrics Uneven or non-uniform lamination application. ¨ ¨

6 Multi Layer Laminated Type III - Laminated fabrics Any pit, blister, tunnel bubbles or delamination of component layers. ¨ ¨

7 Multi Layer Laminated Type III - Laminated fabrics Delamination, separation of film polymer from base cloth. ¨ ¨

Multi Layer Laminated Type III - Laminated fabrics Crease or wrinkle resulting in doubling or adhesion of surfaces that cannot be corrected by manual pressure, adhesion of surfaces against each other or any distortion of face side surface.

9 Multi Layer Laminated Type III - Laminated fabrics Color not a good match to reference. ¨ ¨

Multi Layer Laminated Type III - Laminated fabrics Any area of poor dye penetration, streak or shade bar that is

9-inches or less. Defective shade areas that are greater than 9-inches constitute a failure.

11 Multi Layer Laminated Type III - Laminated fabrics Width not as specified within a tolerance of less than 1/2-inch. ¨ ¨

12 Multi Layer Laminated Type III - Laminated fabrics Objectionable odor. ¨ ¨

13 Multi Layer Laminated Type III - Laminated fabrics Knots greater than Fabric Defect Replica Scale Level D. ¨ ¨

14 Multi Layer Laminated Type III - Laminated fabrics Slubs greater than Fabric Defect Replica Scale Level F. ¨ ¨

Defects

General Statements- Defects Category Description Detail Statement

1 Quality Material General Statement General Statement The finished material shall be examined and scored for the defects listed.

9/5/2025 Page 14 of 19

Defects Material Fabric type Defect Type Defect Description Details Major Minor

15 Multi Layer Laminated Type III - Laminated fabrics Any embedded foreign matter or uncleanness. ¨ ¨

16 Multi Layer Laminated Type III - Laminated fabrics Edges rolled folded, creases, scalloped or corded, baggy, ridgy or wavy cloth. ¨ ¨

Additional defects Part NOS Defect Major Minor

9/5/2025 Page 15 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Additional Packaging Details No Description

Packaging

General Statements- Packaging Category Description Detail Statement

1 General Statement - Packaging

General Preservation, packing and marking shall be as specified in the contract.

2 Length and put-up Material General Statement General Statement For Government procurements only, unless otherwise specified in the contract, the cloth shall be furnished in continuous lengths, each not less than 50 yards, and each length shall be put-up on a roll

3 Roll Identification - Face Material General Statement General Statement he face side of the cloth shall be identified by stamping the face side with the word “FACE” at each end of the roll.

4 Roll Identification - Fiber Material General Statement General Statement Each roll shall be labeled or ticketed for fiber content in accordance with Title 16 CFR 303

5 Width Material General Statement General Statement For Government procurements only, unless otherwise specified, the width of the finished cloth shall be as specified and shall be the minimum acceptable width exclusive of the selvage

9/5/2025 Page 16 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Additional General Statements Category Description Detail Statement

General Statements

General Statements Category Description Detail Statement

1 Distribution Statement A DISTRIBUTION STATEMENT A. Approved for public release. Distribution is unlimited.

2 Comments, Suggestions or Questions

Combat Capabilities Development Command Soldier Center (CCDC SC)

Comments, suggestions, or questions on this document should be addressed to: Combat Capabilities Development Command Soldier Center, 10 General Greene Ave, Natick, MA 01760-5019

3 Non Government Publications

American Association of Textile Chemist and Colorists

(AATCC)

Document Source Copies of these documents are available online at https://aatcc.org

4 Non Government Publications

American Society for Quality (ASQ) Document Source Copies of this document are available online at https://asq.org

5 Non Government Publications

ASTM International Document Source Copies of these documents are available online at http://www.astm.org.

Order of Precedence General Statement Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

Other Government documents, drawings and publications

General Statement The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those specified in the solicitation or contract.

Other Government documents, drawings and publications

Code of Federal Regulations (CFR) Document Source Copies of these documents are available online at https://www.ecfr.gov

Other Government documents, drawings and publications

Environmental Protection Agency (EPA) Document Source Copies of these documents are available online at http://www.epa.gov

9/5/2025 Page 17 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Known Sources Material Product Code Vendor Material Name Comments

Known Sources Others Other Component Vendor Comments

Additional Notes Grid Acquisition Requirement No Acquisition Type Acquisition Requirements

Notes and Concluding Material

General Statements - Notes Category Description Detail Statement

Notes Grid Acquisition Requirement No Acquisition Type Acquisition Requirements

9/5/2025 Page 18 of 19

Description 100% Nylon Laminate - PTFE

MIL/CID Number N/A

Fabric Status In Process

Print/Solid

Fabric Type Multi Layer Laminated

Defect Type Type III - Laminated fabrics

Year 2025

Enterprise DoD | 01

Service AR | Army

Category RM | Raw Material

Sub Category Material |

Size Range zRM - Rolled Goods |

Item Details Intended End Use

Keyword listing

Comments

NSN

Size

Additional Notes

Concluding Material Project Number Preparing Activity

Review Activities Review Activities

Civilian Agencies Civilian Agencies

Custodian Custodian

9/5/2025 Page 19 of 19

File details come from the government source that posted it. Updated .