60-Sec 32 17 26 - ADA DETECTABLE WARNING SURFACE.pdf

PDF 112 KB Posted

Attached to
Morrisville Borough 2026 Design/Build Curb Ramp Project
Solicitation number
Not on record
Issued by
Bucks County, Pennsylvania

About this file

This is a technical specification document for ADA Detectable Warning Surface installation prepared for the Municipal Authority of the Borough of Morrisville, Pennsylvania, as part of the 2026 Design/Build Curb Ramp Project. The work involves the installation of ADA/PennDOT-compliant detectable warning surfaces (DWS) at specified locations within Morrisville Borough. The detectable warning tiles must be manufactured by a PennDOT Bulletin 15 approved manufacturer, constructed as polymer composite material with epoxy polymers and aluminum oxide particles in truncated domes, finished in Brick Red color, and measuring 24 inches nominal width with 0.1875 inch face thickness tolerance of ±5 percent maximum. Installation shall follow manufacturer recommendations and be performed without creating tripping hazards. The specification requires that tiles be protected against damage during the construction period and that all work comply with PennDOT Publication 408 and Borough Standards. Submittals must include manufacturer certifications confirming compliance with designated specifications and documented qualifications demonstrating the installer has minimum five years of tile installation experience and completed similar projects of comparable size and nature.

The detectable warning tiles are provided with a five-year written guarantee covering defective work, breakage, deformation, and loosening of tiles from the date of final completion. The specification document does not address pricing, bid amounts, funding sources, or set-aside designations. Sealed bids for this project are due electronically through PennBid by 10:00 AM on November 13, 2025, and must include a certified check or bid bond of not less than ten percent of the bid amount. The project allows for a base bid and seven alternate bids, with all material, labor, and equipment supplied by the contractor in accordance with applicable standards.

View the file

Other files

File Type Posted
53-Sec 10 14 53 - POST MOUNTED SIGNS.pdf PDF
9-Doc 00 45 10 - BIDDER ACKNOWLEDGEMENT FORM.pdf PDF
45-Sec 01 50 00 - CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS.pdf PDF
39-Sec 01 31 00 - COORDINATION AND MEETINGS.pdf PDF
18-Doc 00 62 16 - CERTIFICATE OF INSURANCE.pdf PDF
35-Doc 00 91 13 - ADDENDA.pdf PDF
29-Doc 00 73 00 6 - RESPONSIBLE - CONTRACTOR ORDINANCE.pdf PDF
48-Sec 01 70 00 - CONTRACT CLOSEOUT.pdf PDF
30-Doc 00 73 00 07 - APPENDIX D - COVER.pdf PDF
13-Doc 00 45 53 - AGREEMENT OF SURETY COMPANY.pdf PDF
54-Sec 31 23 33 - EXCAVATION BACKFILL AND COMPACTION.pdf PDF
32-Doc 00 73 00 08 Part 1 Contract Language Requirements.pdf PDF
42-Sec 01 33 00 - SUBMITTALS.pdf PDF
49-Sec 02 41 16 - DEMOLITION.pdf PDF
6-Doc 00 21 13.1 - INSTRUCTIONS FOR ELECTRONIC BIDDING.pdf PDF
58-Sec 32 13 13 - PORTLAND CEMENT CONCRETE PAVING.pdf PDF
22-Doc 00 72 00 - GENERAL CONDITIONS.pdf PDF
55-Sec 32 01 17.61 - POLYMER MODIFED ASPHALT JOINT AND CRACK SEALING.pdf PDF
46-Sec 01 55 26 - TRAFFIC REGULATION.pdf PDF
38-Sec 01 29 00 - CONTRACT CONSIDERATIONS.pdf PDF
56-Sec 32 12 00 - BITUMINOUS CONCRETE PAVING.pdf PDF
2-Doc 00 01 10-TOC.pdf PDF
24-Doc 00 73 00 1 - APPENDIX A - COVER.pdf PDF
19-Doc 00 65 19.13 - CONTRACTORS AFFIDAVIT.pdf PDF
43-Sec 01 40 00 - QUALITY CONTROL.pdf PDF
31-Doc 00 73 00 07 APPENDIX D - CDBG AND STATE REQUIREMENTS.pdf PDF
36-Sec 01 11 13 - SUMMARY OF WORK.pdf PDF
1-Doc 00 01 01 - TITLE SHEET AND COVER.pdf PDF
5-Doc 00 21 13 - INSTRUCTIONS TO BIDDERS - EBID.pdf PDF
34-Doc 00 73 00 10 - Part 3 Section 3 Requirements.pdf PDF
40-Sec 01 32 16 - NARRATIVE CONSTRUCTION SCHEDULE.pdf PDF
20-Doc 00 65 19.16 - CONTRACTORS RELEASE OF LIENS.pdf PDF
50-Sec 03 11 00 - CONCRETE FORMWORK.pdf PDF
59-Sec 32 17 23.33 - THERMOPLASTIC PAVEMENT MARKINGS.pdf PDF
37-Sec 01 22 00 - MEASUREMENT AND PAYMENT.pdf PDF
25-Doc 00 73 00 1 - APPENDIX A - DAVIS BACON FEDERAL WAGE DETERMINATION.pdf PDF
62-CDBG Curb Ramp Concept Plans.pdf PDF
44-Sec 01 42 13 - ORGANIZATION AND REFERENCE ACRONYMS.pdf PDF
15-Doc 00 61 13.13 - PERFORMANCE BOND.pdf PDF
47-Sec 01 60 00 - MATERIAL AND EQUIPMENT.pdf PDF
16-Doc 00 61 13.16 - PAYMENT BOND.pdf PDF
4-Doc 00 11 13 - ADVERTISEMENT FOR BIDS.pdf PDF
57-Sec 32 12 23 - RESTORATION OF PAVED SURFACES.pdf PDF
52-Sec 03 30 00 - CAST IN PLACE CONCRETE.pdf PDF
61-Sec 32 92 00 - FINISH GRADING, SEEDING, AND SODDING.pdf PDF
41-Sec 01 32 36 - AUDIO-VIDEOTAPING.pdf PDF
23-Doc 00 73 00 0 - SUPPLEMENTARY CONDITIONS.pdf PDF
7-Doc 00 41 00 - BID FORM - EBID.pdf PDF
17-Doc 00 61 19 - MAINTENANCE BOND.pdf PDF
10-Doc 00 45 13 - BIDDER QUALIFICATION STATEMENT.pdf PDF
Show 40 more

Latest 50 of 125 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADA DETECTABLE WARNING TILES

32 17 26-1

SECTION 32 17 26

ADA DETECTABLE WARNING SURFACE

PART 1 GENERAL

1.01 DESCRIPTION OF WORK

A. This Work is the installation of ADA/PennDOT compliant detectable warning surfaces (DWS) at locations specified in the field and on the drawings.

1.02 SUBMITTALS

A. Certifications: Submit certifications that all tiles will meet or exceed designated specifications.

B. Qualifications of Installer:

1. Installer shall have a minimum of five (5) years of experience with tile installations.

2. Installer shall submit for approval, a list of projects similar in nature and size that establishes his/her ability to complete this project. A resume for the project superintendent should be submitted to establish his/her ability to complete the project. If for any reason, the qualifications are not acceptable, work shall not commence until an acceptable installer is found.

PART 2 PRODUCTS

2.01 DETECTABLE WARNING TILES

A. Detectable warning tiles to be manufactured by a PennDOT Bulletin 15 approved manufacturer.

1. Detectable Warning Surfaces shall be compliant with ADA and PennDOT regulations.

2. Detectable Warning Surfaces shall be of the Polymer Composite type composed of epoxy polymers employing aluminum oxide particles in the truncated domes.

4. Detectable warning surface shall be of the embedded cast-in-place type, Brick Red color.

3. Dimensions: Detectable Warning Surfaces shall be held within the following dimensions and tolerances:

Width: 24” nominal

Face Thickness: 0.1875 +/- 5% max.

Warpage of Edge: 0.5% max.

Length: as required to be provided across the full width of the ramp at the grade break near the street edge

B. Color shall be Brick Red.

ADA DETECTABLE WARNING TILES

32 17 26-2

C. Detectable warning surface shall be guaranteed in writing for a period of five years from date of final completion. The guarantee must include defective work, breakage, deformation, and loosening of tiles.

PART 3 EXECUTION

3.01 INSTALLATION

A. Installation shall be performed according to manufacturer’s recommendations.

B. Tile shall be installed in a manner which does not create a tripping hazard.

3.02 CLEANING AND PROTECTION

A. Protect tiles against damage during construction period to comply with manufacturer’s specification.

END OF SECTION