45-Sec 01 50 00 - CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS.pdf
PDF 133 KB Posted
- Solicitation number
- Not on record
- Issued by
- Bucks County, Pennsylvania
About this file
This is a Construction Facilities and Temporary Controls specification document (Section 01 50 00) related to the Municipal Authority of the Borough of Morrisville's 2025 Galvanized Service Replacement project and 2026 Design/Build Curb Ramp Project in Bucks County, Pennsylvania. The specification outlines the contractor's responsibility for providing temporary utilities including electricity, lighting, heat, ventilation, communications, water, and sanitary facilities during construction. The contractor must also establish temporary controls consisting of barriers, enclosures, and fencing; provide protection of work; implement water control and dust control measures; and develop construction facilities including access roads, parking areas, progress cleaning, project signage, and temporary buildings. The contract duration is 45 consecutive calendar days from the Notice to Proceed, with electronic bid submissions required through PennBid by November 13, 2025, at 10:00 AM. Sealed bids must be accompanied by a certified check or bid bond equal to at least 10 percent of the bid amount.
The specification establishes that all costs associated with temporary utilities, sanitary facilities, fencing, water control, and dust control are the contractor's responsibility at no additional cost to the Owner. The contractor must provide a 6-foot-high fence with vehicular and pedestrian gates around the construction site and implement dust control measures as directed by the Owner's Engineer. The contractor is required to maintain the site in a clean and orderly condition through daily waste removal and debris collection, provide security to prevent unauthorized entry and vandalism, and restore all temporary facilities and existing facilities used during construction to original condition upon project completion. Bidders must demonstrate prior experience by having completed at least three similar projects valued at 75 percent or more of the proposed contract amount and provide performance bonds, labor and material payment bonds, and maintenance bonds along with comprehensive insurance documentation. The project focuses on ADA/PennDOT compliant curb ramp installation with sidewalks, curbing, and sign relocation in accordance with PennDOT Publication 408 and Borough Standards, with CDBG funding assistance.
View the file
Other files
Show 40 more
Latest 50 of 125 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS
01 50 00-1
SECTION 01 50 00
PART 1 GENERAL
1.01 GENERAL
A. The Work of this Section shall be the responsibility of the contractor as noted in the Summary of Work (Section 01 11 13).
1.02 SECTION INCLUDES
A. Temporary Utilities: Electricity, lighting, heat, ventilation, communications service, water and sanitary facilities.
B. Temporary Controls: Barriers, enclosures and fencing, protection of the Work, water control and dust control.
C. Construction Facilities: Access roads, parking, progress cleaning, project signage, and temporary buildings.
1.03 RELATED SECTIONS
A. Section 01 57 13: Soil Erosion and Sediment Control.
B. Section 01 55 26: Traffic Regulation.
C. Section 01 70 00: Contract Closeout: Final cleaning.
1.04 TEMPORARY ELECTRICITY
A. Cost: By Contractor; provide and pay for power service required from utility source.
1.05 TEMPORARY SANITARY FACILITIES
A. Provide and maintain required facilities and enclosures.
Existing facility use is not permitted. Provide at time of project mobilization.
B. At end of construction, return facilities to same or better condition than originally found.
1.06 BARRIERS
A. Provide barriers to prevent unauthorized entry to construction areas and to protect existing facilities and adjacent properties from damage from construction operations.
B. Provide protection for plants designated to remain. Replace damaged plants.
C. Protect non-owned vehicular traffic, stored materials, site, and structures from damage.
1.07 FENCING
A. Construction: Contractor's option.
B. Provide 6-foot-high fence around construction site; equip with vehicular and pedestrian gates with locks.
1.08 WATER CONTROL
01 50 00-2
A. Grade site to drain. Maintain excavations free of water. Provide, operate, and maintain pumping equipment.
B. Protect site from puddling or running water.
1.09 PROTECTION OF INSTALLED WORK
A. Protect installed Work and provide special protection where specified in individual specification sections.
B. Provide temporary and removable protection for installed Products. Control activity in immediate work area to prevent damage.
C. Prohibit traffic from landscaped areas.
1.10 SECURITY
A. Provide security and facilities to protect Work, and Owner's operations from unauthorized entry, vandalism, or theft.
1.11 PROGRESS CLEANING AND WASTE REMOVAL
A. Maintain areas free of waste materials, debris, and rubbish. Maintain site in a clean and orderly condition.
B. Collect and remove waste materials, debris, and rubbish from site daily and dispose off-site.
C. Open free-fall chutes are not permitted. Terminate closed chutes into appropriate containers with lids.
1.12 PROJECT IDENTIFICATION
A. No other signs are allowed without Owner permission except those required by law.
1.13 REMOVAL OF UTILITIES, FACILITIES, AND CONTROLS
A. Clean and repair damage caused by installation or use of temporary work.
B. Restore existing facilities used during construction to original condition. Restore permanent facilities used during construction to specified condition.
1.14 DUST CONTROL
A. Execute Work by methods to minimize raising dust from construction operations.
B. Provide positive means (i.e. use of sprinkling water or other methods approved by the Owner) to prevent air-borne dust from dispersing into atmosphere.
C. Dust control measures shall be employed when required in the opinion of the Owner’s
Engineer at no additional cost to Owner.
PART 2 PRODUCTS
Not Used
PART 3 EXECUTION
01 50 00-3
Not Used
END OF SECTION